Digital PDFs
Documents
Guest
Register
Log In
EK-105AA-OW-001
January 1987
168 pages
Original
35MB
view
download
OCR Version
17MB
view
download
Document:
VAXstationII/GPX Owner's Manual, BA123 Enclosure
Order Number:
EK-105AA-OW
Revision:
001
Pages:
168
Original Filename:
OCR Text
VAXstation ll/GPX Owner’'s Manual, BA123 Enclosure Order No. EK-105AA-OW-001 digital jqulpmom corporation maynard, massachusetts First printing, January 1986 Revised, February 1987 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibilityis assumed for the use or reliability of software or equipment thatis not supplied by Digital Equipment Corporation or its affiliated companies. Copyright ©1986, 1987 by Digital Equipment Corporation. All Rights Reserved. The READER’S COMMENTS form on the last page of this document requests the user’s critical evaluation to assist in preparing future documentation. The following are trademarks of Digital Equipment Corporation: DEBET DIBOL ThinWire DEC MASSBUS ULTRIX-32 DECconnect MicroVAX ULTRIX-32m DECmate MicroVMS UNIBUS DECnet PDP VAX DECUS P/OS DECwriter Professional DELNI Q-bus VMS DEMPR Rainbow VT DEQNA RSTS Work Processor DEON; Rr digital DEUNA | - RT VAXcluster VAXstation | 1’«’(JS'I‘L"SCF&IP'I“m is a trademark of Adobe Systems, Inc. Tefiktranix® is a registered trademark of Tektronix, Inc. UNIX® is a registered trademark of American Telephone & Telegraph Company. ML-5635 FCC NOTICE: The equipment described in this manual generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A computing device pursuant to Subpart ] of Part 15 of FCC Rules, which are designed to provide reasonable protection against such radio frequency interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense may be required to take measures to correct the interference. Contents Preface | Description of the VAXstation II/GPX ix . ................... ix Conventions Used in This Document . .. ........... C e e eX Structure of This Document . . ............. e e e . xi Part I: Base System Installation . . ............. Ce xi PartII: Operation. . . .. ........... ... ... ... ..., xi Part I Options. . . . ... oot v, e xi Part IV: Troubleshooting . .. ...................... xi Part V: Appendixes . ............. ... ... .. .. xi Part VI: Glossary . .. ................ e Intended Audience . . .. ............ C et et et e xii e e xii Part I: Base System Installation Chapter 1 Preparing for Installation Check Your Shipment. . ............... e Site-Preparation Review ......... C e eae e e e e 1-1 s e 1-3 Space Planning . ............ Cettt s e e 1-3 The System Unit . . .. .............. Ce e 1-3 The Color Monitor . . . .......... e 1-4 Electrical Requirements . . .. ..................... 1-5 Environment . . . ... ... ettt i e e i e, 1-6 Temperature and Humidity . ................ 1-6 Static Electricity . . . . ... .................. 17 Clean Area . ...... e e e e 1-7 Supplies Storage . ......... ee .. 1.7 Chapter 2 Setting Up the Hardware Setting Up the Color Monmitor . . . .. .................. 2-2 Setting Up the Keyboard and Pointing Device ............ 2-6 Connecting the VAXstation II/GPX to a Power Source . . . ... 2-10 Connecting the VAXstation II/GPX to a Network 2-19 ... ...... Connecting the Ethernet Transceiver Cable to the Workstation 2-19 Connecting to Standard Ethernet .. ................ 2-20 Connecting to ThinWire Ethernet Using the DESTA . . . . .. 2-21 Testing the VAXstation II/GPX . ........... [ 2-24 Part Il: Operation Chapter 3 VAXstation Il/GPX Hardware VAXstation II/GPX Controls and Indicators . . ... e e e 3-1 Halt Enable/Disable Switch (2-position toggle switch). . . . .. 3-3 Power-Up Mode Selection (3-position rotary switch) . . . . . .. 3-4 Baud Rate Selection Switch (8-position rotary switch) . . .. .. 3-4 Light-Emitting Diode (LED) Display ................. 3-4 Printer Port . .. .............. ... ... ee e .. 3-4 The System Power Switch ....................... 3-4 The Restart/Run Pushbutton . . . ... ............. ... 35 The DC OK Indicator. . .. ............ e e e coo. 35 The Halt Pushbutton . . ... ... ..e Ce e Ce e 3-6 The Fixed Disk Pushbuttons . . .................... 3-8 Turning On the System . . . . .................. co.. 3-8 Initial Control Panel Switch Settings . . . .. ... . Cee 3-9 Turning Off the System . . . . .. ... ... ... . ..., 3-10 Color Monitor Controls and Indicators . ............... 3-10 . ............. ... ... .. .. ...... 3-13 Fixed Disk Drive Tape Drive . . . ... ... . ... Inserting a Tape Cartridge. . . . . e iv i e ... i e 3-13 e e e .. 3-14 Rewinding and Unloading a Tape Cartndge ........... 3-16 Protecting Tape Cartridges from Accidental Overwriting 3-18 ... Handling and Storing Tape Cartridges . . . . . . e e e 3-19 Dual Diskette Drive . .......... e e e e Ce 3-19 InsertmgaDnskette.....,,,‘...,. ........ e, 3222 Protecting Diskettes from Accidental Overwnnng ..... .. 3-23 Handling and Storing Diskettes . . . . ... ............ 3-23 Back-up Copies . . . . ... ittt 3-24 Part Ill; Ortiom Chapter 4 Options Hard-Copy Output Devices . . ........................ 4-2 Printers . ................... e Cee e ce. 4-2 TheLNO3 .......... ee e Y - The LNO3 PLUS ......... e e e 4-3 The PrintServer 40 (LPS40) . ................ 4-4 The LA210 . .. ..............S .. 46 The LA75 ........ Ce ee e The LAS0 ..... e e e e The LCGO01 e e e e e 4-7 e e 4-8 ..... e e Plotter . . . ............... e e e e e 4-9 e e 4-10 The LVP16 ........................... 4-10 Printer and Plotter Connection to the System . . ........ 4-11 Input Devices . . .................. e The Tablet . ........ Ce e e The Mouse .. ....... e Memory...........coovin.. C e . 4-13 e . 4-13 e e e e e e c... 4-14 e e e e e e 4-14 The Memory Modules . . . ... .. N 4-14 Video .. ... . i e e .. 4-15 The Video Subsystem ............ C i e e e e 4-15 Storage Devices . . . ... ............ Cvae ke s v ena e . 4-16 The Fixed Disk Drives . . . . . ........ G s 4-16 ... 4-17 . .. .. e e ek eee e e e e ... 4-17 The Tape Drive . . . .. ..... ... .. The Dual Diskette Drive e e s ee e e e Communications . ... ............. .. ... 4-18 The Ethernet Communication Modules . . .. .......... 4-18 ThinWire Ethernet Components . ........A 4-19 ThinWire Ethernet Cable . . . ... ........... 4-19 Connectors . . .................. oo e. . 4-19 . ......... 4-19 .............. 4-19 Barrel Connectors and T-Connectors DESTA and Transceiver Cable Terminators .. ... ... Cee e e ... . 4-20 Connectors and Terminators . . . ....... T . 4-20 Additional Equipment . . . . ... .... ... .. e 421 DIGITAL ThinWire Ethernet Station Adapter (DESTA)4-21 Modems.......................... R 4-22 DF224 . . . . .. . e .. 4-22 DF124 . . . . .. .. e, 4-22 DF112 . . . . e 4-23 DFO3. ... . e 4-23 The DZQ11 Asynchronous Multiplexer . . . ........... 4-23 The DHV11 Asynchronous Multiplexer . . . . .......... 4-24 The DMV11 Synchronous Line Controller . . .......... 4-24 The DPV11 Synchronous Line Controller ............ 4-26 The KMV11 Programmable Controller .. ............ 4-27 Part IV: Troublaahooting Chapter 5 Troubleshooting Procedure Power-up Messages . . ................. e 5-1 Basic Troubleshooting . . . .. ... .......... ... ... ..... 5-2 Replacingthe Fuse . . . . ... ................... 5-10 ColorMonitor . . . .............c.0 ... 5-10 Mouse Maintenance .......... S RS S O 5-13 MicroVAX Diagnostic Monitor . . ..................... The MicroVAX Diagnostic Monitor Main Menu vi 5-17 . ....... 5-17 The System Utilittes Menu . . . ... ................ 5-19 P TM Chapter 6 Service Part V: Aggandixas Appendix A _VAXstation Il/GPX System Specifications Appendix B VAXstation Il/GPX Related Documents e e e B-1 e G Hardware. . . .. . oo v v e e i eeienee ULTRIX SOftware uuuuuuu 5 % W B B W B B A % % B & & B 4 & 8 & & & B & & 5 B ‘B" 2 MimVMS SOftware """"" * L] * * * * » L] *® [ *® - L] * % & ® & # ® # 8 & % @& B“4 Part Vl Gloasag Glossary Index Figures 1-1 1-2 1-3 2-1 2-2 2-3 2-4 2-5 | A VAXstation II/GPX in the BA123 Enclosure . ............ 1-1 Dimensions of the System Unit. ... ... e PP Cee 1-4 Dimensions of the Color Monitor . ........... e 1-5 Keyboard Connection, Color Monitor . . . . . e e e 2-7 Pointing Device Connection, Color Monitor . . . ... .. e 2-9 Monitor Connection to System Unit . . . ... ............. 2-13 Connection to Power Source, Color Monitor . . .......... . 2-17 System Connection to a DELNI. ......... e2-20 3-1 Controls and Indicators . . . ......................... 3-2 3-2 The CPU Distribution Panel . . . ... ........ e 3-3 3-3 Front and Side Controls, Color Monitor 3-4 Rear Controls and Connectors, Color Monitor . ............... ............ 3-11 3-12 4-1 The LNO3....... e e L. 43 4-2 The PrintServer 40 (LPS40) 4-3 The LA210 . . . .. . . 4-4 TheLA75............. e . ................ e oot it e e 4-5 e e e e ... 4-6 e e e e 4-8 4-5 The LAS0...................... e 4-9 4-6 Printer and Plotter Connection to the System . . . . ......... 4-12 4-7 TheTablet ... .. ... ... ... .. . .. 4-13 4-8 Connectors . . ... ..ottt e e e e e 4-20 4-21 4-9 DIGITAL ThinWire Ethernet Station Adapter (DESTA) ....... 5-1 System Circuit Breaker . .. .. e 5-2 Fuse Location, Color Monitor . . ... ... e e e e e 5-3 e e- 5-11 Tables 3-1 Normal Power-On Indications 3-2 Tape Drive Controls and Indicators . . ................. ............... e 3-9 3-17 4-16 4-1 Optional Storage Devices 5-1 System Unit Troubleshooting Procedures . ....................... . 5-2 Fixed Disk and Diskette Drives Troubleshooting Procedures 5-3 Tape Drive Troubleshooting Procedures ................ 5-3 5-4 Monitor Troubleshooting Procedures 5-5 Pointing Device Troubleshooting Procedures A-1 System Electrical Requirements . .................. 5-8 .............- 5-10 . ............e A-1 A-2 System Environmental Requirements A-3 Color Monitor Specifications ... 5-6 ................. 5-7 ........ ee A-2 . ........... e A-2 A-4 Mouse Specifications .. .......... .. ... ... . . 0., A-4 A-5 Tablet Specifications .. ....................... ... AS A-6 RD53 Fixed Disk Drive Specifications . ................ A7 A-7 RD54 Fixed Disk Drive Specifications ..... .. e a e Ce e A-8 A-8 RX50 Dual Diskette Drive Specifications . ........... e A-8 *A-9 TK50 Tape Drive Specifications viii . ..................... A-9 Preface This manual describes how to install, operate, and troubleshoot the VAXstation I1/GPX (Graphics Processing Extension) in the BA123 enclosure. DIGITAL recommends that you read this manual before you install your system. If you experience system problems, use this manual to isolate the error before seeking help from service personnel. Description of the VAXstation 1I/GPX The VAXstation II/GPX is a stand-alone, 32-bit workstation based on the MicroVAX II processor. The system comes with up to 16 megabytes of memory, a video subsystem module, and an Ethernet communications module. Other system components include a 47.5-centimeter (19-inch) diagonal color monitor on a tilt-swivel base, a mouse or tablet, and a keyboard. You may have one or more of the following storage options: a tape drive, diskette drive, or fixed-disk drive. ~ The video subsystem, based on a VLSI (Very Large Scale Integration) graphics coprocessor, off-loads the MicroVAX II main processor from computation- intensive graphics tasks. The system allows parallel processing in multiple planes so that no degradation in performance occurs as planes are added. The 4-plane video subsystem, a 2-module set, can display 16 colors simultaneously. The 8-plane video subsystem, a 3-module set, can display 256 colors simultaneously. The system unit and peripheral devices can be placed on the floor beside a desk. Hardware options include printers, a tablet, a plotter, memory modules, a video module, disk drive subsystems, a tape drive, a dual diskette drive, a fixed-disk drive, asynchronous multiplexers, synchronous line controllers, a programmable communications controller, and a real-time interface module. ULTRIX-32m and MicroVMS are the two operating systems offered for the VAXstation II/GPX. Both operating systems offer workstation software, networking software, and a wide range of tools and applications. Workstation software expands the utility and convenience of the VAXstation II/GPX operating system by providing you with terminals simulated in windows on the monitor screen. Each virtual terminal runs processes independently of processes running in other windows, and the keyboard may be associated with any window at any time. Various software tools allow you to create windows and graphics from a program level. Your workstation software documentation contains additional information on your system and optional hardware. TP Using the mouse or the tablet to move a pointer, you can view Or manage a variety of activities at once. For example, you can do the following: * Examine a compilation listing while editing the source file * Read notices without exiting from a program * Start one task and follow its progress while interacting with another task ® Send mail without exiting an editing session * Log on to a remote VAX host to run tasks requiring intensive computation ® ~ | Print a list of files on your printer while creating other files (requires the printer option) Conventions Used in This Document The following conventions are used in this document: Convention Meaning Bold VAXstation 1I/GPX system controls and indicators are highlighted in bold lettering. | “Quotes” Diagnostic media titles and tests appear in quotations. Italics Computer terms defined in the Glossary are italicized the first time the word appears in the text, beginning with Chapter 1. Structure of This Document The manual is divided into six parts: Part |I: Base System Installation This part describes how to unpack, install, and test the VAXstation II/GPX. * Chapter 1 describes preinstallation procedures, including checking the shipment components and ensuring adequate site preparation. | Chapter 2 describes how to set up, connect, and test the system compo- e nents. Part II: Operation This part describes how to operate the VAXstation II/GPX. e Chapter 3 describes the system controls and indicators. Part lll: Options This part describes the hardware options for the VAXstation II/GPX and gives installation information where applicable. e Chapter 4 describes hard-copy output devices, input device, memory, video devices, disk storage devices, and communications devices. The chapter provides installation information for these options. Part IV: Troubleshooting This part describes how to isolate a problem and decide what to do next. e Chapter 5 explains basic troubleshooting procedures, power-up messages, and the maintenance system for the VAXstation II/GPX. * Chapter 6 describes how to call DIGITAL for help. Part V: Appendixes * Appendix A provides VAXstation II/GPX system specifications. o Appendix B lists related documents. xi Part VI: Glossary The glossary defines computer terms that are italicized at first use in the text as well as other common computer terms. Intended Audience This manual is designed for users with little or no experience installing and using both software and hardware. | Xii Figure 1-1: MLO-487-88 Check Your Shipment Unpack the VAXstation II/GPX system and check your shipment against the packing list on the outside of one of the boxes. WAHNIN@ Because of the weight of the system unit and monitor, you need le to perform this procedure. Your basic shipment consists of three cartons: 1. The VAXstation II/GPX system unit carton contains the following mate- rials: Accessories Kit, containing; - Installation and testing accessories, includiing a flat screwdriver, a , Phillips screwdriver, label sheets, and a grant card (for use by your support personnel) | System unit power cord, loopback connectors, and BNE3x transceiver cable BC18Z video cable assembly | VAXstation II/GPX system unit (BA123 enclosure) 2. Hardware Support Kit (Z4A4B), containing: VAXstation 1I/GPX Hardware Information binder, housing: VAXstation 11/GPX Owner’s Manual, BA123 Enclosure (this manual) VCBO02 Video Subsystem Technical Manual A For systems with TK50s or RX50s: approp a medla for ’testing and troubleshooting (Z4A4B-C5 contains TK50 tape cartridges; Z4A4B-C3 contains RXSD diskettes.) 3. The VAXstation II/GPX consolidation carton contains the following components: . Graphics monitor with installation documentation ®* - ¢ Monitor power cord LK201 keyboard with cable, feet for the keyboard, and an extra power cord * S > VSXXX-AA mouse or tablet with cable NOTE: You must order the keyboard and mouse or tablet separately from the rest of the workstation components. » If you ordered media and documentation, you receive a soffware carton for the operating system you selected. The MicroVMS Workstation Software carton provides keyboard legend strips in addition to media and documentation. 1—2 VAXstation II/GPX Owner's Manual, BA123 Enclosure The software carton also contains the “MicroVAX Dmmaatlc Monitor” used for functional verification of software operation. It is supplied on either a TK50 tape cartridge or an RX50 diskette as you selected, based on your system configuration. If additioml options are purchased at a later date, a new copy of the “MicroVAX Diagnostic Monitor” may need to be ordered. NOTE: If you have a diskless system that contains neither a tape drive nor a diskette drive, contact your service representative for verification of system operation. Check for optional items that you might have ordered, such as additional software or a printer. Refer to the order sheet or packing list on the outside of the cm:mns If your shipment is damaged, or if any item is missing, inform the delivery agent and contact your sales representative. NOTE: Save all boxes and packing material in case you need to send back parts of the system for repair, or if you change work locations. Site-Preparation Review Before installing your VAXstation II/GPX according to the instructions in the next chapter, review thefollowing preparation requirements: . Adeqmte space for the system unit and peripheral devices * Proper electrical power ® A suitable operating environment You may wish to review Appendix A, which provides VAXstation II/GPX system specifications, before you proceed with this chapter. Space Planning Leave sufficient space around the system unit and monitor to access the units and to allow air circulation through the units. The System Unit The vents on the system unit allow proper air flow. Do not block the vents in any way. The unit weighs 59 kilograms (130 pounds). Figure 1-2: Dimensions of the System Unit ,/‘w/ 62.2 cm | (24.5 in) 33cm ""/ (13n) MLO-480-886 The Color Monitor The vents on the monitor allow proper air flow. Do not block the vents in any way. 1—4 VAXstation ll/GPX Owner's Manual, BA123 Enclosure g The color monitor weighs 36 kilograms (80 pounds). Figure 1-3: Dimensions of the Color Monitor 47 cm (18.6 in) 54.6 an (21.5in) 51.8cm | A"| o \N/ MLO-481-85 Electrical Requirements A 20-ampere branch circuit from a power distribution panelis recommended for each system. This circuit must meet national and local standards, provide a good system ground, be stable, and be free from electrical noise. If power disturbances cannot be prevented ‘add more power-conditioning equipment. Consult service personnel to assess your needs. The ac power source shouldsupply power to the original system and allow for system expansion. Do not connect other equipment (such as air conditioners, office copiers, or coffee pots) to the circuit dedicated to the system unit or the monitor. 20~-AMP DEDICATED BRANCH CIRCUIT — 1 PHASE L | POWER POWER CORD CORD DATA CABLE VIDEO CABLE | DO NOT SHARE THE BRANCH CIRCUIT LINES WITH OTHER EQUIPMENT —— | / MLO-482-85 Environment Temperature and Humidity The location of the VAXstation II/GPX should have an environmental control system to maintain the recommended temperature and humidity. This system should filter and evenly distribute air to prevent heat from accumulating. Keep the VAXstation II/GPX away from heaters, photocopiers, or direct sunhght 1—6 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Static Electricity Static electricity can cause a system to fail, data to be lost, and other problems to occur. The most common source of static electricity is the movement of people in contact with carpets and clothing. Low humidity causes the greatest buildup of static electricity. The following precautions reduce static buildup: * Maintain greater than 40% relative humidity. ® Locate the system away from busy areas, such as office corridors. e If a carpet is already fitted at the selected location, place antistatic pads under the system. Clean Ar@a Dust particles can clog air passages inside the equipment, thus reducing the cooling air flow and diskette life, especially if the particles are abrasive. Keeping the system area clean and free from dust helps reduce those effects. Do not pl@ce food or liquid on the system. Supplies Stomge Store supplies, such as diskettes, at the same temperature and humidity levels as recommended for the system. Preparing for Installation 1-—7 Chapter 2 ng Up the Hardware This chapter describes how to asmmble, connect, and test the VAXstation II/ GPX. You should havealready unpacked the system as describedin Chapter 1. | CAUTION: When connecting any component of the VAXstation II/GPX system, set all power switches to the 0 (off) position. WARNING: Because of the weight of the system unit and monitor, you will need two people to perform this procedure. Make sureyow: system unit’s location meets the site-preparation requirements in Chapter 1. To install the VAXstation II/GPX system, follow the steps as directed in this chapter. If you have trouble: * Refer to Chapter 5 for troub ubleshooting information. * Refer to Chapter 6 for service mfmmamon The follomng section explains how to set up the color monitor. Setting Up the Color Monitor 1. Make sure the monitor power switch is set to 0 (off). N COLOR MONITOR POWER SWITCH MLO-600-85 2—2 VAXstation |I/GPX Owner's Manual, BA123 Enclosure 2. Place the monitor on a level surface. Position the monitor for ease of use. NOTE: Make sure the tilt-lock lever is on the right when you face the monitor. ~ _TILT-LOCK LEVER MLO-801-88 3. Adjust the monitor to a position you find comfortable. To tilt the monitor, » a. Slide the tilt-lock lever away from you (toward the back of the monitor) to unlock the monitor from the base. b. Tilt the monitor to the desired position. c. Slide the lever toward you to lock the monitor in place. Setting Up the Hardware 2—3 4. Locate the BC18Z video cable assembly from the system unit carton. Plug the ends of the R, G, and B video cables into the corresponding R, G, and B sockets on the back of the monitor. clockwise to fasten. ] ] Turn each connector ' s m"m% 1 BCl8Z VIDEO CABLE ASSEMBLY TO SYSTEM MLO-502-85 2—4 VAXstation II/GPX Owner's Manual, BA123 Enclosure e 5. Screw the video cable assembly knob clockwise into the monitor. TO SYSTEM | | MLO-503-85 Setting Up the Keyboard and Pointing Device 1. Install the keyboard feet. Sy KEYBOARD FEET KEYBOARD (BOTTOM VIEW) MLO-865-86 2—6 VAXstation Il/GPX Owner's Manual, BA123 Enclosure 2. Connect the keyboard cable to the video cable assembly. Figure 2 1: Keyboard Connection, Color Monitor CABLE ASSEMBLY Setting Up the Hardware 3. Locate the pointing device you wish to use, which may be either a mouse or a tablet with a puck or stylus. Both devices cannot be used at the same time. 4. Plug the pointing device cable into the video cable assembly. NOTE: Attach the puck or stylus before connecting the tablet to the VAXstation I1/GPX. The instruction sheet that comes with the tablet explains how to connect the various components. Save this sheet for future reference. To change the puck or stylus, first disconnect the tablet from the VAXstation I1/GPX, then swap the puck or stylus, and reconnect the tablet to the system. MOUSE TABLET TABLET PUCK TABLET STYLUS MLO--506A-86 2—8 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Figure 2-2: Pointing Dey ice Connection, Color Monitor MLO-857-86 Connecting the VAXstation II/GPX to a Power Source 1. | - - Make sure that all pushbuttons on the control panel of the system unit are in the out position. - POWER | -““““”“,uwflflrf Nl rl 1 RESTART RUN PUSHBUTTON — DC OK | 8 PUSHBUTTON // =13 HALT PUSHBUTTON WRITEPROTECT PUSHBUTTON READY PUSHBUTTON <« : MLO-509-85 Locate the labels sheet in the Accessories Kit of your shipment. Put the appropriate label on the control panel, as shown above. If your unit contains diskette drives, label the left drive 1 and the right drive 2. 2—-10 VAXstation II/GPX Owner's Manual, BA123 Enclosure en|the back door of your system unit by pulling out the left side. A p fastemr holds the doorin place. MLO-B11-88 6. Set the controls located on the CPU distribution panel insert on the back of the system unit to the following positions: * Halt Enable/Disable switch to the disable position (down) ®* Mode switch to the middle (language inquiry) position e System Unit baud rate at 4800 baud NOTE: The panel uses international symbols rather than text. illustration as a guide. Use the HALT ENABLE/DISABLE SWITCH (DOWN POSITION) | POWER-UP MODE 'SELECTION SWITCH BAUD RATE SELECTION SWITCH MLO-512-86 2—-12 VAXstation Il/GPX Owner's Manual, BA123 Enclosure 7. Connect the free end of the color monitor video cable to the back of the system unit as illustrated. | Figure 2—-3: Monitor Connectio to System Unit TO MONITOR L MLO-513-86 8. Install and connect any uninstalled options. Option modules ordered with your initial system order come preinstalled. C@mnect additional devices in any order. Read Chapter 4 for descriptions of the options and installation infor- mation. Also refer to the documentation included with additional devices. 9. Locate the monitor and system unit power cords. The two cords are the same type and interchangeable. Ensure that the plugs fit the wall outlet. 100-120 V \ <mmmwmmmwmmm POWER CORD 200-250 V MLO-B17-88 2—-14 VAXstation 1l/GPX Owner's Manual, BA123 Enclosure 10. Read and remove the 1abe1 mvemg the power connector of the system unit. 11. Check the Vflltaga switchsetting of the system unit. If necessary, change the switch setting to match the voltage source. To change the setting, use a pen or screwdriver to move the switch to the correct pOSltl(m CAUTION: An incorrect voltage switch setting will damage the VAXstation 11 /GPX system. READ AND | taeL | | | : 120V (100-120 V) VOLTAGE SWITCH 220 V (200-250 V) MLO-618-88 2-15 12. Before you connect the VAXstation II/GPX to a power source, make sure that the monitor power switch is set to 0 (off), the pushbuttons on & \\ the system unit front control panel are out, and the power switch on the system unit front control panel is set to 0 (off). The power switch is located on the front of the VAXstation II/GPX system unit in the following illustration. MLO-819-85 2—-16 VAXstation II/GPX Owner's Manual, BA123 Enclosure P 13. Connect the monitor power cord to the monitor first and then to an outlet. action to Power Source, C Tt 11 ) TO OUTLET MLO-B21-B6 emm«,%% 14. Plug in the ends of the system power cable. e Thread the cable through the system cable guide and plug one end firmly into the system unit power connector. * Insert the other end of the system power cable into the wall receptacle ' TO OUTLE;\ MLO-522-88 Run the power and other cables in areas where no one will trip over them. Avoid straining or bending the cables. Leave the back door of the system unit open. You will be instructed to close it in the section entitled Testing the VAXstation II/GPX in this chapter. 2—-18 VAXstation |I/GPX Owner's Manual, BA123 Enclosure Connecting the VAXstation 1I/GPX to a Network You can connect your workstation to either a standard or ThinWire Ethernet network. NOTE: For a more detailed description of networking, consult the DECconnect System Guides. Connecting the Ethernet Transceiver Cable to the Workstation To connect a transceiver cable to the VAXstation II/GPX: 1. Set the system unit power switch to 0 (off). 2. Attach the BNE3x transceiver cable to the back of the system unit, routing the cable through the cable guide slot. CABLE GUIDE MLO-810-86 You can connect the other end of the cable to a DELNI or DESTA or have your service representative connect your system to an H4000 transceiver port. Setting Up the Hardware 2—-19 Connecting to Standard Ethernet To connect the VAXstation II/GPX to a DELNI, plug the female end of the BNE3x cable into a free port of the DELNI. Figure 2-5: System Connection to a DELNI CONNECTION (OPTIONAL) ‘ POWER CORD MLO-515-86 NOTE: To communicate over an Ethernet network, you must install communication software supported by your operating system. Contact your service representative to connect your system to an H4000 transceiver port. See Chapter 4 for more information on the DELNI and DESTA. 2—-20 VAXstation II/GPX Owner's Manual, BA123 Enclosure Connecting to ThinWire Ethernet Using the DESTA 1. Attach ThinWire cable to one side of the T-connector as shown in the following illustration. T-CONNECTOR CONNECTOR WLO- 78286 2. If the system is the first or last system in a single ThinWire segment, attach a terminator to the side of the T-connector not connected to the ThinWire cable as shown in the following illustration. CONNECTOR T-CONNECTOR TERMINATOR WLO-T790-88 Setting Up the Hardware 2-—-21 3. If the system is not the first or last system and you want to connect another system to the ThinWire cable, do not attach a terminator to the T-connector. Add another section of ThinWire cable to the T-connector as shown in the following illustration. CONNECTOR T-CONNECTOR CONNECTOR MLO-784-86 / DESTA 0 1 T-CONNECTOR e CONNECTOR MLO--795-86 2—22 VAXstation Il/GPX Owner's Manual, BA123 Enclosure 5. Attach the 15-pin connector on the transceiver cable to the DESTA. 15-PIN DESTA CONNECTOR TRANSCEIVER CABLE DESTA CONNECTOR T-CONNECTOR MLO--796-86 Setting Up the Hardware 2—-23 Testing the VAXstation 1I/GPX The first time you power up your system, check the various components of your system. If you have neither a tape drive nor a diskette drive, contact your service representative for testing of your system. If you have either a . tape or diskette drive, follow these steps: 1. If you have a fixed disk, push the Fixed Disk Ready pushbutton on the control panel to put the fixed disk off-line. TM, OPTIONAL r/ FIXED DISKS FIXED DISK READY PUSHBUTTON MLO-628-85 2. Power up the monitor by setting the monitor power switch to 1 (on). NOTE: After setting the system power switch to 1 (on), the monitor displays the language selection menu. Ignore the data on this screen until you have inserted the diagnostic medium as directed by this manual. If the video display does not appear in about 30 seconds, refer to Chapter 5. 3. Power up the VAXstation II/GPX by setting the system unit power switch to 1 (on). You may use either a TK50 tape drive or an RX50 diskette drive to load diagnostics into your system. Your system can contain both types of load devices. 2—-24 VAXstation |I/GPX Owner's Manual, BA123 Enclosure — If you are using a tape drive to load diagnostics, proceed to step 4. If you are using a diskette drive to load diagnostics, proceed to step 6 (skip steps 4 and 5). . Find the tape cartridge labeled “MVII Diag. Cust. TK50” in the cartridge - holder at the front of this binder. § i | O | iR S MINI | WRITE-PROTECT SWITCH Bd ) W K : LABEL MLO-831-85 Setting Up the Hardware 2—-25 5. Insert the tape cartridge into the tape drive by following these steps: a. Make sure you set the system power switch to 1 (on). You cannot move the cartridge release handle if the power switch is set to 0 (off). b. After the Tape Activity indicator glows green, open the tape drive by lifting the cartridge release handle. c. With the arrow on the tape cartridge facing up, insert the tape cartridge into the tape drive. POWER SWITCH TAPE ACTIVITY INDICATOR IS GLOWING GREEN CARTRIDGE RELEASE HANDLE MLO-B32A-85 d. Push down the cartridge release handle. Push in the Load/Unload pushbutton. The pushbutton glows red. When the Tape Activity indicator glows green, the tape is ready for use. Proceed immediately to step 8 (skip steps 6 and 7). LOAD/UNLOAD PUSHBUTTON INDICATOR IS GLOWING RED MLO-5328-85 2—-26 VAXstation Il/GPX Owner's Manual, BA123 Enclosure CAUTION: Do not lift the cartridge release handle until the Load/ Unload pushbutton extinguishes and the Tape Activity indicator glows green. Do not lift the cartridge release handle while an indicator light flashes. NOTE: For a more detailed discussion of the TK50 tape drive controls and procedures, refer to Chapter 3. 6. Find the diskettes labeled “MVII Diag. Cust. RX50” in the diskette holder at the front of this binder. softare MVII DIAG. CUST. RX50 © 1983 Digrtat € quipment Corporation WRITE-PROTECT NOTCH § MLO-529-8 Setting Up the Hardware 2-27 7. Insert the diagnostic diskette labeled “#1” by following these steps: a. Open drive 1. The diskette drives contain a cardboard shipping card. Remove the cardboard card prior to diskette insertion. b. Aligning the orange arrow on the diskette with the orange stripe on the drive, insert the diskette. c. Close drive 1. MLO-830-86 The language selection menu display appears on the monitor screen automatically. 2—28 VAXstation II/GPX Owner's Manual, BA123 Enclosure 8. From the language selection menu displayed on the monitor, select the language to match your keyboard by pressing the corresponding number key and then pressing RETURN. KA630-A.V1.2 1) Dansk 7) Nederlands 2) 3) 4) 5) 6) 8) 9) 10) 11) Deutsch English Espafiol Frangais Italiano Norsk Portugués Suomi Svenska (1..11): MLO-833-85 If you select English, French, or German, a second menu appears. Select which variant of the language you prefer. For example, if you select English, you have the following choices: ® United Kingdom ® United States/Canada The monitor slowly displays the numbers 7 through 3, indicating completion of steps in the power-up test. The last part of the display contains the numbers 2 through 0, indicating that the system is loading “MicroVAX Maintenance System” software. Performing normal system tests. 7..6..5..4..3.. Tests completed. Loading system software. 2..1..0 NOTE: If you neglected to or took too much time to insert the diagnostic medium, the monitor displays a “?54 retry” error message. Insert the diagnostic medium into the load device (if you have not already done so) and press the Restart pushbutton to reboot the system. Setting Up the Hardware 2—29 After the power-up test finishes, the introductory display of the “MicroVAX Diagnostic Monitor” appears. MicroVAX Diagnostic Monitor CONFIDENTIAL DIAGNOSTIC SOFTWARE PROPERTY OF DIGITAL EQUIPMENT CORPORATION Use Authorized Only Pursuant to a Valid Right-to-Use License Copyright (c) 1987 Digital Equipment Corporation Current date and time is: 25-Jun-1987 12:30:10 Press the RETURN key to continue OR enter new date and time, then press the RETURN key. [DD-MMM-YYYY HH:MM]: 9. Make sure the date and time in the introductory display are accurate. If the date and time are accurate, press RETURN. If the date and time are inaccurate or not known, type the correct date and time, following the format as shown. 12:30:10. Press RETURN. An example is 25-JUN-1987 The test preparation display informs you that the system is preparing for testing. This process takes a few minutes. If you have an RX50 diskette drive, text instructs you to remove the diskette labeled “#1” and insert the diskette labeled “#2”. The system informs you if additional diskettes are required to complete testing. NOTE: If your system does not prompt you for all the diskettes in the diagnostics package, your system configuration does not require the additional diskettes for testing. 2—-30 VAXstation Il/GPX Owner's Manual, BA123 Enclosure 10. When the diagnostics are loaded, text tells you to remove the diskette or tape cartridge and to press RETURN. The monitor displays the “Diagnostic Monitor Main Menu”. describes each of the options. Chapter 5 | NOTE: Do not select a menu choice until this manual directs you to. MAIN MENU 1 - Test the system 2 - Show System Configuration and Devices 3 - Display the System Utilities Menu 4 - Display the Service Menu 5 - Exit MicroVAX Diagnostic Monitor Type the number: then press the RETURN key. > Setting Up the Hardware 2—31 11. Turn the Mode switch counterclockwise on the back of the system unit to the next position to save the language you selected in step 8. Close the back door of the system unit. G POWER-UP MODE — SELECTION SWITCH Baud MLO-B37-85 2—-32 VAXstation Il/GPX Owner's Manual, BA123 Enclosure 12. Select the “System Test” diagnostic by typing 1 and then pressing RETURN. These diagnostics check the system components. A few moments later, the monitor displays the “System Test” screen. MAIN MENU SYSTEM TEST This is a test of the MicroVAX computer and its devices. No additional preparation for this testing is required; the MicroVAX is ready to be tested. Testing occurs in two parts: The functional tests quickly test each device sequentially; the exerciser test (lasting about 4 minutes) tests how the devices work together. To halt the test at any time and return to the Main Menu, type CTRL-C by holding down the CTRL key and pressing the C key. Press the RETURN key to begin testing, OR type O and press the RETURN key to return to the Main Menu. Setting Up the Hardware 2—-33 > 13. Press RETURN to begin testing. The monitor displays several messages to inform you of the progress of the system tests, then the following color bar display appears: BLACK BLUE RED MAGENTA | GREEN CYAN YELLOW WHITE MLO-B3BA-B5 After about 4 minutes, a message telling you the system has passed the testing appears on your screen. SYSTEM TEST PASSED All devices passed functional tests and the system passed the exerciser test. At this point you may exit from the MicroVAX Diagnostic Monitor or perform more specialized testing. like additional information, If you would consult the system documentation. Press the RETURN key to return to the previous menu. 2—-34 VAXstation 1l/GPX Owner's Manual, BA123 Enclosure You have successfully installed and tested your VAXstation II/GPX system. NOTE: If you see error messages, refer to the troubleshooting section of Chapter 5. 14. Press RETURN to get back to the “Main Menu”. The “Main Menu” shown in step 8 is displayed. Chapter 5 describes the diagnostic tests. 15. Type 5 and press RETURN to exit. The monitor displays the following: Exiting MicroVAX Diagnostic Monitor Exit complete. You may now load your system software. 16. If you have a fixed disk, push the Fixed Disk Ready pushbutton on the control panel to put the fixed disk back on-line. To rewind and unload the TK50 tape cartridge from the tape drive, press the Load/Unload pushbutton to the out position. When the procedure is complete, the Load/Unload pushbutton stops glowing and the Tape Activity indicator glows green. Pull out the cartridge release handle, remove the tape cartridge, and push in the cartridge release handle. See Chapter 3 for more details on this procedure. You are now ready for software installation. If you are unfamiliar with the system controls and indicators, read Chapter 3, which covers system operation, before installing the software. After you have installed the software, read the rest of this manual. Setting Up the Hardware 2—35 g e . e oy Chapter 3 VA Xstation 11/GPX Hardware This chapter contains information on the following topics: e VAXstation II/GPX controls and indicators ¢ Turning on the VAXstation II/GPX e Turning off the VAXstation II/GPX e Color monitor controls and indicators e Fixed disk drive e Tape drive and tapes e Dual diskette drive and diskettes ® Back-up copies VAXstation 1I/GPX Controls and Indicators The front control panel (Figure 3-1) contains the following controls and indicators: e System power switch * Restart/Run momentary-contact pushbutton e e DC OK indicator Halt pushbutton Fixed Disk Write-protect pushbutton e Fixed Disk Ready pushbutton VAXstation 1I/GPX Hardware 3-—1 Figure 3—1: Controls and Indicators POWER SWITCH - — VAXstation P I/GPX RESTART/RUN PUSHBUTTON —__ DC OK g PUSHBUTTON o1 el HALT - WRITE-PROTECT = = READY PUSHBUTTON 4 PUSHBUTTON D - R PUSHBUTTON MLO-642-85 Additional controls and indicators are located on the CPU distribution panel on the back of the VAXstation II/GPX system unit. 3—2 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Figure 3-2: The CPU Distribution Panel HALTS ENABLED / HALT ENABLE/DISABLE SWITCH ICON HALT TM | |l| — E/DISABLE ENABL o ' " POWER-UP MODE . SELECTION SWITCH V , 2aof IV HALTS DISABLED (eo |~ DISPLAY ‘ ' / _ NORMAL OPERAT ION D E GE INQTUIRMODY MOD LANGUA / __ ]/ E __—~ LOOPBACK TES O | | BAUD RATE SELECTION SWITCH , , PRINTER _~” PORT : MLO-807-86 The switches, indicator, and connector on the CPU distribution panel provide the following functions: Halt Enable/Disable Switch (2-position toggle switch) Switch Position Function Up (dot inside circle) Halts are enabled. On power-up or restart, the system will enter console I/O mode at the completion of startup diagnostics. Down (dot outside circle) Halts are disabled. On power-up or restart, the system will attempt to load software from one of the boot devices at the completion of start-up diagnostics. VAXstation II/GPX Hardware 3—3 Power-Up Mode Selection (3-position rotary switch) Switch Position Arrow Mode Run. If the system supports the Multinational Character Set (MCS), the user will be prompted for language only if the battery backup has failed. Full start-up diagnostics are run. Face Language inquiry (factory setting). If the system supports MCS, the user will be prompted for language on every power-up and restart. Full start-up diagnostics are run. T in a Circle Test. ROM programs run wraparound serial-line unit (SLU) tests. Baud Rate Selection Switch (8-position rotary switch) This switch sets the baud rate of the console terminal serial-line. The factory The baud rate of this switch must match that of the printer, if present. setting is 4800 baud. Light-Emitting Diode (LED) Display This indicator displays numbers of on-going steps of power-up tests and booting procedures. If a failure occurs, the display indicates the field replaceable unit (FRU) that is the most probable cause of the failure. Refer to Chapter 5, under the section titled Power-Up Messages, for a brief description of the hexadecimal numbers. Printer Port This is a 9-pin connector for a cable to a printer. The System Power Switch POWER SWITCH dlifglit]all VAXstation I/GPX y MLO-643-85 3—4 VAXstation |I/GPX Owner's Manual, BA123 Enclosure The system power switch controls the ac power. Setting the switch to 1 turns on the power. Setting the power switch to 0 turns off the power. The Restart/Run Pushbutton Restart/ Run MLO-544-85 The Restart/Run momentary-contact pushbutton reboots the operating system software when pushed. Work in progress is lost. When the system is on, the Restart/Run pushbutton glows green to indicate normal software operation. If the pushbutton does not glow, refer to Chapter 5 for troubleshooting information. The DC OK Indicator DC OK MLO-545-85 The DC OK indicator glows green when the system is generating power. If the indicator does not glow, the system is not generating power. Refer to Chapter 5 for troubleshooting suggestions. VAXstation Il/GPX Hardware 3—5 The Halt Pushbutton ® | Halt MLO-546-85 The Halt pushbutton stops the program currently running without shutting down the VAXstation II/GPX. When the Halt pushbutton is pressed, it latches in and glows orange. The Halt pushbutton should be set in the out position and not glowing to allow for software operation. The Halt Enable/Disable switch (on the back of the VAXstation II/GPX cabinet) is normally set to the disable position (up) to prevent the system from going into console mode when you execute a halt in a program. The disable position also stops devices (such as a printer) connected to the auxiliary port from halting the processor. To get into console mode, shut down any software that may be executing and put the Halt Enable/Disable switch (located on the back of the system unit) in the enable position (down). Then, press the Halt pushbutton twice. Any data not saved before pressing the pushbutton will be lost. The MicroVAX II Maintenance Manual describes the console commands. You can also enter console mode from the workstation software. Consult your system software documentation. 3—6 VAXstation |I/GPX Owner's Manual, BA123 Enclosure HALT ' ENABLE/DISABLE [J SWITCH (UP POSITION) MLO-546A-85 VAXstation II/GPX Hardware 3—7 The Fixed Disk Pushbuttons WriteProtect ® | Ready MLO-547-85 Your system may contain one or more fixed disks with external pushbuttons. If your system does not have a fixed disk, these pushbuttons are inoperable. The Fixed Disk Write-Protect pushbutton is set in the out position and not System software can read or write information on the disk. To write protect the disk, preventing system software from erasing or writing on the disk, push in the Write-Protect pushbutton. The pushbutton glows orange. glowing for normal software operation. The Fixed Disk Ready pushbutton glows green when it is set to the out position and indicates that the fixed disk is ready to store information. When pushed in, the pushbutton stops glowing, and the fixed disk is disabled. In effect, the fixed disk is turned off. Turning On the System This procedure assumes that the system has been installed according to the installation instructions in this manual and that the system software has been installed. If the system software has not been installed, consult the software documentation and install the software. 3—8 VAXstation |I/GPX Owner's Manual, BA123 Enclosure Initial Control Panel Switch Settings 1. If you have a fixed disk, set the Fixed Disk Ready pushbutton to the out (ready) position. 2. Set the monitor power switch to 1 (on). 3. Set the system power switch to 1 (on). When you turn on the power, the VAXstation II/GPX control panel indicators appear as described in Table 3-1. Table 3—1: Normal Power-On Indications Control/Indicator Normal Indication Restart/Run Glows green DC OK Glows green Halt Not glowing Fixed Disk Write Protect: Not glowing Fixed Disk Ready: Glows green within 30 seconds Tape Drive Load/Unload: Glows red for 4 seconds and then stops glowing Monitor Power Indicator: Glows green If you do not observe the indications listed in Table 3-1, refer to Chapter 5 for troubleshooting information. The monitor displays the power-up screen. Performing normal system tests. 7..6..5..4..3.. Tests completed. Loading system software. 2..1..0 The monitor slowly displays the numbers 7 through 3, indicating completion of steps in the power-up system test. The VAXstation II/GPX performs power-on system tests each time you turn on the system. Then, the monitor displays the numbers 2 through 0 to indicate that the The first screen VAXstation II/GPX system is loading the system software. for the system software appears on the monitor after a few seconds. VAXstation Il/GPX Hardware 3—9 The VAXstation II/GPX system is now ready for use. Refer to the system software documentation for instructions on using the VAXstation II/GPX system. | Turning Off the System To prevent loss of data and to ensure an orderly system shutdown, follow the system shut-down procedure described in your system software documentation. Turn off the VAXstation II/GPX system by setting the power switch to 0 (off). CAUTION: Before moving the monitor, turn it off and wait 30 seconds to allow static electricity on the CRT to discharge. Color Monitor Controls and Indicators The front and side of the monitor have the following six controls and ~indicators: The contrast control lets you adjust the video display. The brightness control allows you to adjust the video raster (background intensity) to compensate for ambient light in the room. To adjust the raster, set the brightness control to minimum. Slowly turn up the control until horizontal lines appear on the screen, then reduce the brightness until the lines disappear. The degauss switch lets you clear picture distortion caused by external Press the degauss switch after any movement of the monitor interference. to correct color distortions. If you need to press the degauss switch a second time, first wait 10 minutes to allow the circuit to reactivate. The power switch enables you to turn on or off the monitor. Press 1 to turn on the power. Press 0 to turn off the power. The tilt-lock lever enables you to adjust the angle of the monitor. Set the tilt-lock lever back to adjust the tilt. Pull the lever forward to the original position to lock the monitor at the desired angle. The lock prevents the tilting mechanism from moving the monitor. You can swivel the monitor on the base, and the angle will be maintained. 3—-10 VAXstation 1I/GPX Owner's Manual, BA123 Enclosure The power indicator glows to indicate that power is applied to the monitor. Figure 3-3: Front and Side Controls, Color Monitor CONTRAST BRIGHTNESS DEGAUSS POWER ON/OFF \TILT-LOCK LEVER POWER INDICATOR | FRONT VIEW MLO-550-85 VAXstation Il/GPX Hardware 3—11 The back of the monitor has the following six connectors and controls: The end of the R, G, and B video cables plug into the R, G, and B sockets. The monitor, keyboard, and pointing device are joined to the system unit through the video cable assembly, which screws into the cable assembly mounting hole. The fuse protects the monitor from electrical damage. The monitor power cord plugs into the power cord connector. Figure 3—4: Rear Controls and Connectors, Color Monitor R G SOCKET B SOCKET CABLE ASSEMBLY MOUNTING HOLE FUSE POWER CORD CONNECTOR REAR VIEW 3-12 VAXstation II/GPX Owner's Manual, BA123 Enclosure MLO-562-86 Fixed Disk Drive The fixed disk drive, located inside the cabinet, stores information on a nonremovable disk. The RD53 fixed disk stores up to 71 megabytes of data. The RD54 fixed disk stores up to 159 megabytes of data. Fixed disk systems are usually configured to include the TK50 tape drive for removable storage of data. FIXED DISK DRIVE MLO-488-86 Tape Drive The TK50 tape drive holds one removable TK50 magnetic tape cartridge. The information is magnetically stored on one side of a TK50 tape. Information can be erased, and new information stored in its place. Each tape cartridge holds 94.5 megabytes of information. The tape cartridge can be used as both an input and output device. As an input device, it can be used to load software or data into the system. As an output device, the cartridge can be used to make copies (backups) of software or data on the tape cartridge media. The tape drive has two primary controls: the cartridge release handle and the Load/Unload pushbutton. The cartridge release handle is used to insert or remove cartridges and lock them into position. The Load/Unload pushbutton controls winding and rewinding of the tape. The pushbutton is a 2-position control; when the pushbutton is first pressed in, the tape winds VAXstation II/GPX Hardware 3—13 onto the take-up reel inside the drive. When pressed again, the pushbutton pops out and winds the tape back into the tape cartridge. TK50 CARTRIDGE RELEASE HANDLE TK50 LOAD/UNLOAD PUSHBUTTON INDICATOR \ TK50 TAPE ACTIVITY INDICATOR Inserting a Tape Cartridge Make sure the system power switch is set to 1 (on) and the Load/Unload pushbutton is not glowing. The Load/Unload pushbutton glows red for approximately 4 seconds during the tape drive power-on self test. The pushbutton stops glowing, and the Tape Activity indicator glows green to show that you can begin the following procedure. 1. Pull out the cartridge release handle. 2. With the arrow on the tape cartridge pointing toward the cartridge release handle, insert the cartridge into the drive. 3. ® The Load/Unload pushbutton glows red. * The Tape Activity indicator stops glowing. Push in the cartridge release handle to lock the tape in the operating position. ® The Load/Unload pushbutton stops glowing. * The Tape Activity indicator glows green. 3—-14 VAXstation II/GPX Owner's Manual, BA123 Enclosure 4. Press in the Load/Unload pushbutton. e The Load/Unload pushbutton glows red. e The Tape Activity indicator stops glowing. The tape is loaded in 10-15 seconds. If a tape is new, the system performs a calibration sequence that takes approximately 40 seconds. The Tape Activity indicator flashes green rapidly and irregularly during calibration. During loading, the Load/Unload pushbutton glows red. When the Tape Activity indicator glows green, the tape is ready to use. TAPE ACTIVITY INDICATOR 1S GLOWING GREEN CARTRIDGE RELEASE HANDLE LOAD/UNLOAD PUSHBUTTON INDICATOR IS GLOWING RED MLO-859-85 CAUTION: Keep the cartridge release handle down when the Load /Unload pushbutton glows red. Make sure the Tape Activity indicator glows green before lifting the cartridge release handle. | VAXstation Il/GPX Hardware 3—15 CAUTION: If the Load/Unload pushbutton flashes red rapidly at any time, press it four times. If the problem persists, do not attempt to use the tape drive or to remove the tape cartridge. Call your service representative. Rewinding and Unloading a Tape Cartridge Rewind and unload a tape before removing it from the tape drive. 1. Press the Load/Unload pushbutton to the out position. * The Load/Unload pushbutton and Tape Activity indicators flash slowly, but not in unison, as the tape rewinds to the beginning (unless the tape was already at the beginning). * The Load/Unload pushbutton glows red, and the Tape Activity indicator stops glowing as the tape unloads into the cartridge. * 2. When the procedure completes, the Load/Unload pushbutton stops glowing and the Tape Activity indicator glows green. Pull out the cartridge release handle. Remove the tape cartridge and store it in a safe place. 4. Push in the cartridge release handle. The Tape Activity indicator glows green, showing that power is supplied to the drive. NOTE: Rewinding a tape can also be done under software control. Refer to your software documentation for information. 3-16 VAXstation II/GPX Owner's Manual, BA123 Enclosure Table 3g—-2: Tape Drive Controls and Indicators Control Position Condition Load/Unload Pushbutton In Slowly flashing. Tape is loading (10-15 seconds). Rewinding and loading can take up to 2 minutes. Out Tape Activity Load/Unload Pushbutton Tape is rewinding and unloading. Indicator Indicator Condition Off Off No power to the tape drive. On Off Off On Safe to lift cartridge release handle to insert or remove a tape. Power is present. Unsafe to lift the cartridge release handle. ® Power-on self test is occurring—glows for only 4 seconds. ® (Cartridge is inserted but handle is still up. ¢ Tape is loading or unloading. ® Tape is stopped. On On Tape loaded successfully. Flashing On Tape is in motion (except rewind). Read/ write commands are being processed. Irregular fast flashing means tape calibration is occurring. Tape is rewinding. Flashing Flashing Flashing Flashing rapidly =~ A fault is occurring. Press and release the Load/Unload pushbutton four times. If the problem persists, do not attempt to use the tape drive or to remove the tape cartridge. Call your service representative. lif a tape is new, the system performs a calibration sequence that takes approximately 40 seconds. VAXstation Il/GPX Hardware 3-17 Table 3-2 (Cont.): Tape Drive Controls and Indicators Handle Position Function Cartridge Release Handle Out Allows a tape to be inserted or removed after rewind and unload operations are completed. In Locks tape in operating position. Protecting Tape Cartridges from Accidental Overwriting The TK50 tape cartridge has a write-protect feature to prevent loss of data by accidental overwriting. To write-protect the tape, slide the write-protect switch toward the tape label slot. TAPE CARTRIDGE WRITE-PROTECT SWITCH NOT WRITEPROTECTED WRITEPROTECTED MLO-858-86 NOTE: The system can read information on the tape, regardless of the position of the write-protect switch. However, the system cannot write data to the tape when the switch is set to the write-protect position. 3-18 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Handling and Storing Tape Cartridges Follow th;ese guidelines when handling and storing TK50 tape cartridges: e Do not touch the exposed surface of the tape. e Do not throw or drop the tape cartridge. ® Store tape cartridges in a dust-free environment. e Do not apply adhesive labels to the top, bottom, or sides of a cartridge. Place labels only in the label slot on the front of the tape cartridge. e Write on the identification label before inserting it in the label slot on the front of the cartridge. e Allow new blank and prerecorded tapes to stabilize at room temperature for 24 hours before using them. | * Keep tape cartridges away from direct sunlight, heaters, and other sources of heat. Store tape cartridges in a stable temperature between 10 and 40 degrees Celsius (50 and 104 degrees Fahrenheit). e Keep tape cartridges away from magnets and equipment such as motors, transformers, terminals, monitors, and audio equipment, that generate magnetic fields. o Keep tapes away from x-ray equipment. Dual Diskette Drive The RX50 dual diskette drive holds up to two 13.13-centimeter (5.25-inch) diskettes. Each diskette stores 400 kilobytes of information, which is roughly 150 typewritten pages. Close the drive door when using a diskette. The drive does not work with the door open. VAXstation II/GPX Hardware 3—19 A Diskette Activity indicator on each drive glows red when a drive is in use. Keep the drive doors closed when the Diskette Activity indicators are glowing red. Opening the doors could erase data or delete information. || DISKETTE ACTIVITY Ly INDICATORS MLO-B53-88 The information on RX50 diskettes is magnetically stored on one side of the diskette. Stored information can be erased, and new information stored in its place. OO 3—20 VAXstation Il/GPX Owner's Manual, BA123 Enclosure The diskette, permanently enclosed in a cover, rotates inside the cover. The soft fabric lining of the cover continuously cleans the diskette. NOTE: Use only formatted RX50 diskettes, available from DIGITAL or DIGI- TAL'’s licensed distributors. DISKETTE LABEL DISKETTE g~ WRITE-PROTECT ~ NOTCH CQVER . DISKETTE SURFACE DO NOT ORANGE TOUCH ARROW PROTECTIVE ENVELOPE 1 ] MLO-564-85 VAXstation II/GPX Hardware 3—21 Inserting a Diskette Keep the diskette drive door closed while a Diskette Activity indicator is glowing red. Opening the door might damage the drive heads. Wait for the indicator to stop glowing, which indicates that diskette drive activity has finished. a. Open the drive door by pressing on the door’s outer edge. b. Align the orange arrow on the diskette cover with the orange stripe on the drive and insert the diskette. The write-protect notch is down for drive 1 and up for drive 2. c. After inserting the diskette, press the drive door closed. excessive force; the door should close easily. MLO-556-86 3—22 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Do not use Protecting Diskettes from Accidental Overwriting The RX50 diskette has a write-protect feature to prevent loss of data from accidental overwriting. To protect the data, cover the write-protect notch on the side of the cover with a self-adhesive foil tab supplied with your diskettes. Remove the tab when you want to add, change, or delete information. ) wRiTE- PROTECT TAB MLO-5566-85 Handling and Storing Diskettes Incorrect handling and storing of diskettes can damage them (and the RX50 recording head) and cause loss of data. The following precautions should be taken: ® To keep out dust and dirt, put the diskette in its envelope when the diskette is not in use. e Do not fold or bend the diskette cover. ® Do not touch the recording surface of the diskette. When out of its envelope, handle only the top (label area) of the diskette. ® Store the diskette vertically (with the label at the top) and loosely to prevent the cover from becoming warped. ®* Write on the label before applying it to the diskette cover to avoid creasing the cover. If you need to change the label, use a felt-tipped pen. e Store the diskette away from direct sunlight and heaters. ® Store the diskette away from strong magnetic fields and steel objects. Magnetic fields (produced by motors, transformers, and terminals) can erase data. VAXstation II/GPX Hardware 3—23 Back-up Copies A back-up copy is a copy of files stored on the VAXstation II/GPX fixed disk, diskette, or tape. Making back-up copies of files ensures a copy for you in case information is accidentally lost. As a general rule: * Make back-up copies on diskettes or magnetic tape. ®* Make a daily back-up copy of information you create or change that day. * Make a weekly back-up copy of information stored on your fixed disk drive. * Store back-up copies in a safe place. Make back-up copies of system software files as described in the system software documentation. 3—24 VAXstation II/GPX Owner's Manual, BA123 Enclosure Chapter 4 Options The options currently supported by the VAXstation II/GPX are divided into six categories and consist of the following: * Hard-copy Output Devices—Printers and Plotter (LN03, LN03 PLUS, LAS50, LA75, LA210, LPS40, LCGO01, and LVP16) ® Input Devices—Tablet (VSXXB-AB), Mouse (VSXXA-AA) ® Memory—Memory Modules (MS630-BA, MS630-BB, MS630-CA) ® Video—4-Plane (M7168) Module ® Storage Devices—Fixed Disk Drives (RD53 and RD54), Tape Drive (TK50), and Dual Diskette Drives (RX50) * Communications—Ethernet communication module (DEQNA), ThinWire Ethernet connectors and terminators, the DIGITAL ThinWire Ethernet Station Adapter (DESTA), Asynchronous Multiplexers (DZQ11 and DHV11), Synchronous Line Controllers (DMV11 and DPV11), Programmable Controller (KMV11), and Modems (DF03, DF112, DF124, and DF224). This chapter describes each option and directs you to the appropriate installation instructions. You may install a printer, the tablet, and the color monitor yourself. However, contact your service representative to install all the other options. The VAXstation II/GPX is also upgradeable to a 2-user ULTRIX system having two monitors, two keyboards, two input devices, and two VCB02 graphics modules. Contact your sales representative for information on this upgrade. CAUTION: If you attempt to install the memory modules, video module, disk drive subsystems, tape drive, dual diskette drive, communications module, asynchronous multiplexers, synchronous line controllers, or programmable controller, you might damage the system. Options 4—1 To order an option after initial system installation, contact your sales rep- resentative. For more information on those options, refer to the documents listed at the end of each section! and the VAXstation 11/GPX Maintenance Manual. Hard-Copy Output Devices The VAXstation II/GPX can be used with seven printers: the LN03, the LN03 PLUS, the LPS40, the LA210, the LA75, the LA50, and the LCGO01. The VAXstation II/GPX can also be used with the LVP16 plotter. Each of the following sections describes one of these options. The final section explains how to connect a printer or plotter to a VAXstation II/GPX. Printers The LNO3 The LNO3 laser printer is a desk-top, nonimpact printer that produces letterquality text at 8 pages/minute. For systems running MicroVMS, the printer can also display graphics. The LNO03 offers 16 fonts, including Courier, Elite, and the VT100LineDrawing Set (the DIGITAL standard set), ASCII multinational technical character sets and 12 national language character sets can also be used. The printer comes with three character sets. If you want to mix type styles and point sizes, the LN03 can print up to 24 fonts/page. To expand memory or add additional fonts, you can purchase more programmable RAM or precoded ROM cartridges from DIGITAL. The LNO3 uses only cut sheet paper. A paper cassette holds 250 sheets of paper. The printer automatically collates output for you in its facedown output tray. The LNO03 can also handle preprinted single-part forms, transparencies, and labels. The LN03 can print in either landscape (horizontal) or portrait (vertical) mode. CAUTION: When the LNO3 or LNO3 PLUS is connected to an operating VAXstation I1/GPX, make sure the Halt Enable/Disable switch is disabled before powering on and off the system. Otherwise, you cause the irretrievable loss of data. | 1 These documents pertain only to customers in the United States. If you are not a U.S. customer or if you require translated documents, check the appropriate country’s product listing. 4-—-2 VAXstation |I/GPX Owner's Manual, BA123 Enclosure The LNO3 weighs 28 kilograms (66 pounds). Figure 4-1: The LNO3 33cm (13 in) MLO-B62-86 To order an LNO3 printer after the initial system installation, contact your sales representative. You can install the LNO3 printer yourself. After assembling the printer, see the section Printer and Plotter Connection to the System. For more information about the LN03 printer, see the following documents: * Installing and Using the LNO3 (Order No. EK-0LN03-UG-001) ® LNO3 Programmer Reference Manual (Order No. EK-0LN03-RM-001) ® LNO3 Maintenance Kit Guide (Order No. EK-LN03U-MG-001) ® LNO3 Toner Kit Guide (Order No. EK-0LN03-MG-001) The LNO3 PLUS The LNO3 PLUS is the upgrade configuration of the LNO3 laser printer. The LNO3 PLUS system consists of a base LN03 laser printer and an LN03S bitmap option module. The LN03 PLUS requires the firmware microcode V4.4 to be installed in the base LNO3 printer. Options 4-—3 The LN03 PLUS enhances the ability of the LNO3 printer to print documents composed of text and graphics. The LN03 PLUS enables you to process ANSI and Tektronix data files with any ratio of text to graphics and with no limits on image complexity. The LNO03S bitmap option module consists of a printed circuit board that is inserted into the available option slot of the LNO03 printer. This option modaule’s key featureis an on-board memory capacity of one Mbyte of dynamic RAM used for bitmap storage. The LN03S option module also contains up to 128 Kbytes of ROM for program and font storage. The printer and host system communicate through the standard RS232-C serial interface. All setup features in the LN03 PLUS are the same as in the base LN03 and are controlled through the default setting of configuration switches or under program control. CAUTION: When the LN03 or LN03 PLUS is connected to an operating VAXstation 11/GPX, make sure the Halt Enable/Disable switch is disabled before powering on and off the system. Otherwise, you cause the irretrievable loss of data. To order an LN03 PLUS printer or an LN03S option module for installation into an existing LNO3 printer, contact your sales representative. The PrintServer 40 (LPS40) The PnntServer 40 is a MicroVAX II-based laser printer containing POST- SCRIPT® software. The PrintServer 40 is designed as an Ethernet node in order to serve many users. A dedicated MicroVAX II-based data controller interprets applications programs that output in POSTSCRIPT, a powerful industry-standard page description language. The PrmtServer 40 supports existing software, using ANSI text/ sixels, ReGIS, or Tektronix® 4010/4014 format through the use of host-based translators. The PrintServer 40 prints monochromatically at a rate of 40 pages per minute at a resolution of 750 x 750 dots per centimeter (300 x 300 dots per inch). Paper sizes include letter, legal, and ledger, and A4, A5, B4, and BS metric sizes. A large capacity input tray holds 2000 sheets of cut sheet paper and two auxiliary trays hold 250 sheets each. The PrintServer 40 contains a library of 29 typefaces that may be scaled to any point size, rotated to any degree, and positioned anywhere on a page, through the use of POSTSCRIPT commands. 4-4 VAXstation II/GPX Owner's Manual, BA123 Enclosure Specifications for the PrintServer 40: * Size: 102.62 cm (40.4 in) high x 72.14 cm (28.4 in) deep x 152.4 cm (60 in) wide ¢ Weight: 219.99 kilograms (484 Ib) * Voltage: * 200/208/240 V, 60 Hz e 200/220/230/240 V, 50 Hz Figure 4—2: The PrintServer 40 (LPS40) ¢ » Options 4-5 The LA210 The LA210 is a dot-matrix desk-top printer that can produce high-speed drafts (240 characters/second) or near letter-quality correspondence (40 characters/ second). With the addition of an optional font cartridge, the LA210 can print memo-quality correspondence (80 characters/second). The LA210 also prints bitmap graphics. The printer can print in USASCII, 10 national languages in Courier 10, and the VT100 line-drawing set (the DIGITAL standard set). Other features include three optional typefaces: Gothic, Orator, and Italic. Over 30 optional character sets, including symbols and technical characters, can be added by plug-in font cartridges. You can select up to eight character widths. The LA210 prints on single-sheet and fanfold paper and handles forms with up to four parts. The printer’s carriage accommodates paper ranging in width from 8.9 centimeters (3.5 inches) to 37.8 centimeters (14.9 inches). The printer weighs 11.3 kilograms (25 pounds). Figure 4—-3: The LA210 54.6 cm | (21.5 in) (13.5 in) MLO-661-86 To order an LA210 printer after the initial system installation, contact your sales representative. You can install the LA210 printer yourself. After assembling the printer, see the section Printer and Plotter Connection to the System. 4—-6 VAXstation II/GPX Owner's Manual, BA123 Enclosure For more information about the LA210 printer, see the following documents: ® Installing the LA210 Letterprinter (Order No. EK-LA210-IN-001) ® [LA210 Letterprinter User Guide (Order No. EK-LA210-UG-001) ® LA210 Letterprinter Programmer Reference Manual (Order No. EK-LA210RM-001) ® LA210 Letterprinter Operator and Programmer Reference Guide (Order No. EK-LA210-RC-001) ® LA210 Letterprinter Emulation Modes Reference Guide (Order No. LA210-RG-001) EK- The LA75 The LA75 is a desk-top dot-matrix printer that can produce sixel-protocol bitmap graphics. The LA75 prints in draft speed (250 characters/second), memo speed (125 characters/second), and letter-quality speed (32 characters/second). The printer offers optional font cartridges and international character sets. You can use office stationery or fanfold paper. The LA75 is compatible with DIGITAL’s LA50 and LA210 printers as well as IBM’s PRO printer. The LA75 uses the DEC423 serial interface. The LA75 weighs 10 kilograms (22 pounds). Options 4-—7 Figure 4—4: The LA75 f«x“ “’ L p § oy ’/ "y vu‘,'n,» .hvwww % ’« $ w"” ‘(‘ ,« ,N uw .w m, ,n ‘m - : “: 42.7 cm {16.8 in}) % o i e (13.6 in) ."“‘J ‘ MLO-788-86 To connect the LA75 printer to your VAXstation II/GPX you need an adapter, the H8571-B and a cable, either the BC16E-10 (30.48 meters/10 feet), BC16E25 (76.2 meters/25 feet), or the BC16E-50 (152.4 meters/50 feet). To order an LA75 printer and the necessary cable and adapter after the initial system installation, contact your sales representative. The LA5S0 The LA50 is a desk-top dot-matrix printer that can produce bit-map or character cell graphics. The LA50 prints in draft speed (100 characters/second) and memo speed (50 characters/second). The printer offers one font and six character widths. Ten national character sets are available. You can use office stationery or fanfold paper. The LA50 weighs 8.5 kilograms (18.7 pounds). 4—-8 VAXstation |I/GPX Owner's Manual, BA123 Enclosure Figure 4-5: The LAS0 | 14.2c¢m (5.6 in} (16 in) MLO-860-85 To order an LA50 printer after the initial system installation, contact your sales representative. You can install the LA50 printer yourself. After assembling the printer, see the section Printer and Plotter Connection to the System. For more information about the LA50 printer, see the following documents: o e Installing and Using the LA50 Printer (Order No. EK-0LA50-UG) LA50 Printer Programmer Reference Manual (Order No. EK-0LA50-RM- 001) The LCGO1 The LCGO1 is a high-resolution serial ink-jet color printer. The LCGO01 provides 385 dots/centimeter (154 dots/inch) resolution and it prints in 216 . colors. The printer offers five different fonts. One is ROM resident, and the others are down-line loaded at system startup. The LCGO01’s automatic sheet feeder holds paper and transparencies. Options 4—9 The LCGO1 color printing system consists of the LCGO01 color printer and an LCGO1 graphics protocol processor. The LCGO1 printer weighs 31.8 kilograms (70 pounds), and the controller weighs 11.7 kilograms (26 pounds). The printer measures 21.6 centimeters (8.5 inches) x 61 centimeters (24 inches) x 61.6 centimeters (24.25 inches). To order an LCGO1 color printing system after the initial system installation, contact your sales representative. You can install the LCG01 yourself. After assembling the printer, see the section Printer and Plotter Connection to the System. For more information about the LCGO01, see the following documents: ® LCGO1 Installation and Operator Manual (Order No. EK-LCP01-IN) e LCGO1 User’s Guide (Order No. EK-LCP01-UG) ® LCGO1 Pocket Service Guide (Order No. EK-LCP01-PS) Plotter The LVP16 The LVP16 is a high-performance 6-pen color graphics plotter. The LVP16 prints graphics at 38 centimeters/second (15 inches/second). Using any of 19 character sets, the LVP16 can annotate graphs with text in any direction, with or without character slant, and in varying sizes. The LVP16 is accurate to 0.025 millimeter (0.001 inch). Multicolor high-quality graphics are produced by programs, using the front- panel selection of six pens. For drawing with additional colors, the program can be stopped, and additional pens can be manually installed. The fiber-tip pens are available in two nib sizes along with a selection of ten vibrant colors for paper and seven for transparencies. The LVP16 can be used with plain paper or transparencies. Each page is manually removed and inserted for every plotting. The LVP16 weighs 7 kilograms (16 pounds) and measures 12.7 centimeters (6 inches) x 56.8 centimeters (22.4 inches) x 36.7 centimeters (14.5 inches). To order an LVP16 plotter after initial system installation, contact your sales representative. You can install the LVP16 plotter yourself. After assembling the printer, see the section Printer and Plotter Connection to the System. 4-10 VAXstation II/GPX Owner's Manual, BA123 Enclosure To properly operate the LVP16, set the rocker switches according to the following list. This information supplements the LVP16 Graphics Plotter Owner’s Manual. e B1 through B4 control baud rate. For example, set B1 and B4 to on for a 4800-baud rate. * The next two switches control paper size. For example, set to US and A4 for United States letter size paper. * The Y/D switch controls cabling. The D setting is for a direct connection, and the Y setting is for the eavesdrop connection. e The S1 and S2 switches control byte size and parity. Set both to off for 8-bit bytes and no parity checking. For more information about the LVP16, see the following documents: ® LVP16 Graphics Plotter Owner’s Manual (Order No. EK-LVP16-OM) ® LVP16 Graphics Plotter Programmer Reference Manual (Order No. EK- LVP16-RM) ® The LVP16 Reference Card Printer and Plotter Connection to the System Cables are required to connect a printer or plotter to the VAXstation II/GPX. The LNO03, LA210, LA50, and LCPO1 printers require the BCCO8 cable, and the LVP16 plotter requires the BCC19 cable. You must order a cable in addition to the printer or plotter. For systems running ULTRIX, you must also add print commands to the system (see the ULTRIX Workstation Software and Management Guide) and set the printer for 7-bit ASCII (refer to the appropriate printer manual). To connect a printer or plotter to a VAXstation II/GPX, follow the instructions below. 1. Make sure that the power switches for the printer or plotter and the VAXstation I1/GPX are off. 2. Open the back door of the system unit. 3. Check that the printer or plotter and the system unit are set to the same baud rate (4800). 4. Attach the larger end of the printer or plotter cable to the back of the printer or plotter. Options 4-11 5. Attach the free end of the printer or plotter cable to the printer port on the I/0O distribution panel, which is located on the rear of your VAXstation II/GPX (see Figure 4-6). Figure 4—6: Printer and Plotter Connection to the System TO PRINTER 1/0 DISTRIBUTION PANEL < BAUD RATE SELECTION SWITCH N -/ 6. PRINTER PORT MLO-563-85 Close the back door of the system unit. NOTE: If you are connecting the LA210 printer to the VAXstation 11/GPX, make sure that XOFF and wrap are enabled. This may require toggling switches on the printer as explained in the LA210 documentation. 4-12 VAXstation II/GPX Owner's Manual, BA123 Enclosure Input Devices The Tablet The tablet system consists of a digitizing tablet, a puck, a 2-button stylus, and a 1.5-meter (5-foot) power/signal cable. The tablet with the puck or stylus may be used as a pointing device instead of the mouse for menu selection, graphics entry, and cursor control. The tablet is an input device that sends X-Y coordinates to the VAXstation II/GPX puck on the tablet’s surface. The tablet has a resolution of 79 counts/ millimeter (200 counts/inch). The stylus is used like a pen, while the puck is similar to a mouse, but instead glides on a felt bottom. The tablet communicates with the VAXstation II/GPX through an asynchronous, full-duplex serial interface at 4800 baud (+/-2%). The active area of the tablet is 279 millimeters x 279 millimeters (11 inches x 11 inches). The tablet weighs 3.2 kilograms (7 pounds). Figure 4—-7: FEET The Tablet TABLET PUCK STYLUS MLO-564-B5 To order a tablet after the initial system installation, contact your sales representative. To install the tablet yourself, see Chapter 2. Options 4-13 For more information about the tablet, see: ® Tablet Information Sheet (Order No. EK-VSXXB-IN) The Mouse The mouse is a small, circular, plastic-bodied input device with three buttons. You use the mouse and buttons to position the cursor, enter graphics, and select on-screen items. Signals from the mouse are transferred to the monitor through a 1.5-meter (5-foot) cable. Memory The Memory Modules The VAXstation II/GPX comes with a minimum of 5 megabytes of memory. Optional memory expansion modules allow you to expand to a total of 16 megabytes of memory. The following describes the additional memory expansion modules: Part Number MS630-BA Description 2M Memory Expansion Module, quad-height module with 256K RAM (half populated MS630-BB). MS630-BB 4M Memory Expansion Module, quad-height module with 256K RAM. MS630-CA 8M Memory Expansion Module, quad-height module with 256K RAM. To order a memory module after the initial system installation, contact your sales representative. Contact your service representative to install a memory module. For more information about the memory modules, see: ® KA630-A CPU Module User’s Guide (Order No. EJ-KA630-UG) L PSITON 4—-14 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Video The Video Subsystem One VCB02 Video Subsystem consists of: * The M7169 base module ®* One or, optionally, two M7168 4-plane modules The VAXstation II/GPX is also available as a 2-user system with two VCB02 video subsystems, two color monitors, two input devices, and two keyboards. The 4-plane module provides high-performance, high-resolution, full-page direct memory access (DMA) color video subsystems based on the Q22-bus. The module, based on a VLSI graphics coprocessor, off loads the MicroVAX II/GPX main processor from computation-intensive graphics tasks. The VAXstation II/GPX’s existing 4-plane video subsystem can display 16 colors simultaneously. If a second 4-plane module is added, the video subsystem is upgraded to an 8-plane video subsystem, which can display 256 colors simultaneously. The modules allow parallel processing in multiple planes so that no degradation in performance occurs as planes are added. The 4-plane module provides variable character size or positioning and inherent graphics capability. The module’s major hardware components are: four video processor (DC322) chips, four planes of video memory with two pages/plane, subsystem support logic, video shifters, and cable connectors for the base module interface. To order an additional 4-plane (M7168) module after initial system installation, contact your sales representative. Contact your service representative to install this option. For more information on the 4-plane module, see the following document: * VCBO02 Video Subsystem Technical Manual (Order No. AZ-GLGAB-MN), which is in this binder. Options 4-15 Storage Devices The VAXstation II/GPX has four mass storage devices available as options. They are: e The RD53 fixed disk drive * The RD54 fixed disk drive * The TK50 tape drive ® The RX50 dual diskette drive Table 4-1 shows the optional storage devices, the option package number, and the controller that allows your system to access the storage device. You can add optional storage devices up to your system’s limit. Contact your sales or service representative to determine your system’s specific requirements. Table 4—1: Optional Storage Devices Storage Device Option Package Order Number! Required Controller Fixed Disk Drives | RD53 RD53A-BA RQDX3-BA RD54 RD54A-BA RQDX3-BA Tape Drive TK50 | TK50-AA TQK50-BA RX50A-BA RQDX3-BA Dual Diskette Drive RX50 1The option packages contain the storage device and necessary parts to completely connect it to your system. The Fixed Disk Drives The two fixed disk drives available for the VAXstation II/GPX are the RD54 and RD53. The RD54 has a formatted capacity of 159 megabytes. The RD53 has a formatted capacity of 71 megabytes. A fixed disk drive provides additional data storage for the VAXstation II/GPX. The fixed disk drive is mounted inside the system enclosure. The VAXstation II/GPX in a BA123 Enclosure supports a maximum of four fixed disk drives with either a 4- or 8-plane video subsystem. Contact your service representative for information about your specific system capacities. 4-16 VAXstation II/GPX Owner's Manual, BA123 Enclosure To order a fixed disk drive after the initial system installation, contact your sales representative. Contact your service representative for installation. For more information about the fixed disk drives, refer to the following documents: ® RD53 Disk Drive Technical Description (Order No. EK-RD53A-TD-001) * RDS54 Disk Drive Technical Description (Order No. EK-RD54A-TD-001) The Tape Drive The TK50 tape drive, with a TK50 tape cartridge, provides additional data storage for your system and can be used to load software, including system diagnostics. For a more complete description of the TK50 tape drive, see Chapter 3. To order a TK50 tape drive after the initial system installation, contact your sales representative. You will need to order the tape drive, the TK50 tape cartridge, and the signal cable option package. Contact your service representative to install these options. For more information about the TK50 tape drive, see the following documents: ® TK50 Tape Drive Subsystem Owner’s Manual (Order No. EK-LEP05-OM) ® TK50 User’s Guide (Order No. EK-OTK50-UG-001) ® TK50 Technical Manual (Order No. EK-OTK50-TM-001) The Dual Diskette Drive For a description of the RX50 dual diskette drive, see Chapter 3. To order an RX50 dual diskette drive after the initial system installation, contact your sales representative. You will need the dual diskette drive option package (RX50A-BA) and the signal cable option package (17-00867-01). Contact your service representative to install this option. For more information about the dual diskette drive, see the following document: ® The RX50 Diskette Drive Technical Description (Order No. TD-001) EK-RX50A| Options 4—-17 Communications The Ethernet Communication Modules The DEQNA is a Q22-bus-compatible communication module that interfaces between an Ethernet Local Area Network (LAN) and a VAXstation II/GPX. With a DEQNA module interface and communications software, the VAX- station II/GPX system becomes a node on a network and can communicate with other computers that are also nodes on the network. The DEQNA also enables a VAXstation II/GPX to be down-line loaded with a system image from a host computer on the network. | If the DEQNA module board is ordered after initial system installation, you must contact your service representative to install it. Once the modules are installed, the VAXstation II/GPX may join an existing Ethernet network either through a DELNI or an H4000 transceiver. The DELNI (Digital Equipment Local Area Network Interconnect) is a lowcost Ethernet device consisting of a short section of coaxial cable containing eight transceivers. Each transceiver supplies a port for one system on the network. The DELNI is limited to a range of 35-40 meters (112-128 feet), but can be expanded through a connection to a second DELNI or to a larger Ethernet network. The ninth port on the DELNI allows for such a connection. To order a DELNI, contact your sales representative. The H4000 Ethernet Transceiver can accommodate a more extensive network. The H4000 can be configured with 100 nodes for each 500-meter (1600-foot) segment. The transceiver consists of a small printed circuit board and a cabletapping assembly contained in a rugged plastic housing. This installation also requires a transceiver cable. To order an H4000 or transceiver cable, contact your sales representative. You may connect the system to a DELNI yourself. However, you must contact your service representative to connect the VAXstation II/GPX to an H4000 transceiver. You need a BNE3x cable in order to connect a DELNI or an H4000 transceiver to a VAXstation II/GPX. To order additional cable, contact your sales repre- sentative. The BNE3x transceiver cable comes in four types: e BNE3A—PVC, straight connector e BNE3B—PVC, right-angle connector e BNE3C—Teflon, straight connector e BNE3D—Teflon, right-angle connector 4-18 VAXstation Il/GPX Owner's Manual, BA123 Enclosure The BNE3x cable comes in different lengths, specified by the part number extension to the type of cable desired. Part No. Extension Length -05 5 m (16.4 ft) -10 10 m (32.8 ft) -20 20 m (65.6 ft) -40 40 m (131.2 ft) For example, a BNE3C-20 is a 20-meter (65.6-foot) Teflon, straight connector. For any questions regarding your specific requirements, contact your service representative. ThinWire Ethernet Components This section describes the ThinWire Ethernet components you can use to connect your VAXstation II/GPX, using ThinWire Ethernet. ThinWire Ethernet Cable The maximum recommended length of cable leading from a terminator to the last station on a segment of ThinWire Ethernet is 185 m (606 ft). At least 0.5 m (1.6 ft) is required between stations. Connectors A ThinWire section is a single length of RG58C or equivalent cable. You will need two connectors, one at each end, for each section of ThinWire cable. Barrel Connectors and T-Connectors A ThinWire segment is one or more sections of ThinWire cable interconnected by barrel or T-connectors. You need one T-connector for each DESTA and VAXstation I1/GPX. DESTA and Transceiver Cable If you want to connect a VAXstation II/GPX or any devices like the bridge, repeater, or server that use transceiver cables to connect to ThinWire Ethernet, you will need a DESTA and a transceiver cable. Options 4—-19 Terminators You need one terminator for each end of a ThinWire segment. Connectors and Terminators The ThinWire connectors and terminators you need to configure your ThinWire network follow: ® T-connector (H8223)—A 3-way connector that joins two ThinWire Ether- net cable sections. The third opening attaches to the system unit. ® Terminator (H8225)—A connector at the end of a ThinWire segment that provides the 50-ohm termination resistance needed for the cable. If the ThinWire cable connects to a DIGITAL ThinWire Ethernet Multiport Repeater (DEMPR), then a terminator is only needed at one end of the cable. e Barrel connector (H8224)—A recessed connector that connects two ThinWire Ethernet cable sections. Figure 4-8 shows the connectors and terminator you need to connect to ThinWire Ethernet. Figure 4-8: Connectors T-CONNECTOR CONNECTOR TERMINATOR MLO--789-B6 BARREL CONNECTOR 4-20 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Additional Equipment Use the following equipment to connect a system with a transceiver cable to ThinWire Ethernet: * DIGITAL ThinWire Ethernet Station Adapter (DESTA-AA) DIGITAL ThinWire Ethernet Station Adapter (DESTA) The DESTA is an Ethernet/IEEE 802.3 transceiver that connects systems that have transceiver-type connectors to ThinWire Ethernet. A transceiver is a device that provides a single physical connection between standard Ethernet and Ethernet communication equipment. The DESTA has two ports: one port connects to the T-connector connected to ThinWire, a second port connects a transceiver cable that leads to the system. | Figure 4-9 shows a DESTA. The DESTA provides: * * Connection of a system with a transceiver cable to ThinWire Ethernet. Attachment to devices connected to Ethernet communication controllers by way of transceiver cables. Figure 4-9: DIGITAL ThinWire Ethernet Station Adapter (DESTA) MLO-791-88 Options 4-21 For more information on these options, see the following documents: e DEQNA User's Guide (Order No. EK-DEQNA-UG) e MicroVAX Handbook (Order No. EB-25156-47) e DELNI Installation and Owner’s Manual (Order No. EK-DELNI-IN) e Ethernet Installation Guide (Order No. EK-ETHER-IN) Modems Four modems are available for use with the VAXstation II/GPX: Modem Description DF224 300, 1200, and 2400 bps (bits per second) full-duplex synchronous/ asynchronous DF124 1200 and 2400 bps full-duplex synchronous/asynchronous DF112 300 and 1200 bps full-duplex synchronous/asynchronous DFO03 300 and 1200 bps full-duplex synchronous/asynchronous DF224 The DF224 modem provides full-duplex communication at speeds of 300, 1200, and 2400 bps (asynchronous) and 1200 and 2400 bps (synchronous). The DF224 allows both rotary pulse and pushbutton dialing over dial-up or leased-line networks. The DF224 contains an auto-dialer with memory and provides autoanswer capability in addition to manual operation. A data/talk switch and automatic adaptive equalizer are also provided. The DF224’s diagnostics test the modem at each power up. | DF124 The DF124 modem provides full-duplex communication at speeds of 1200 and 2400 bps (asynchronous and synchronous) over dial-up or leased-line networks. The DF124 contains an autodialer with memory, a data/talk switch, and diagnostic self-tests. 4-22 VAXstation Il/GPX Owner's Manual, BA123 Enclosure DF112 The DF112 modem communicates at 300 and 1200 bps full-duplex (asynchronous and synchronous) over dial-up or leased-line networks. An autodialer with memory and data/talk switch are provided. The DF112 is compatible with rotary dial and pushbutton dialing. DFO03 The DF03 modem is a 300 and 1200 bps full duplex (asynchronous and synchronous) modem. To order a modem after initial system installation, contact your sales representative. The DZQ11 Asynchronous Multiplexer The DZQ11 is an asynchronous multiplexer that connects the Q22-bus with up to four asynchronous serial data communications channels. A dual-height module, the DZQ11 connects hard-copy and video terminals, with or without modems, to a system. With a VAXstation II/GPX, the DZQ11 can also be used as an asynchronous DECnet link. The DZQ11 allows dial-up (autoanswer) operations with modems capable of full-duplex operation, such as DIGITAL’s models DF03, DF112, DF124, and DF224. The DZQ11 provides flexible control of parameters, such as baud rate (50 to 9600), character length, number of stop bits for each line, odd or even parity for each line, and transmitter-receiver interrupts. Additional features include limited data set control, break generation and detection, and silo buffering of received data. To order a DZQ11 after the initial system installation, contact your sales representative. You will need to order a base module (DZQ11-M) and a cabinet kit (CK-DZQ11-DA). Contact your service representative to install the DZQ11. For more information about the DZQ11, see: e DZQ11 Asynchronous Multiplexer User’s Guide (Order No. ’EKWDZQI 1UG-001) Options 4—23 ‘The DHV11 Asynchronous Multiplexer The DHV11 is an asynchronous multiplexer that connects up to eight serial lines to a Q-bus for data communications. The DHV11, a quad-height module with programmable functions, connects hard-copy and video terminals to the VAXstation II/GPX. The DHV11 allows dial-up (auto-answer) operations with modems capable of full-duplex operation, such as DIGITAL’s modems DF03, DF112, DF124, and DF224, Applications for the DHV11 cover data concentration, terminal interfacing, and cluster controlling. The features include full modem control, DMA or silo output, silo input buffering, programmable split speed, and module throughput of 1500 characters/second. To order a DHV11 after the initial system installation, contact your sales representative. You will need to order a DHV11 base module (DHV11-M) and cabinet kit, which includes filter connectors and cables (CK-DHV11-AB). Contact your service representative to install the DHV11. For more information about the DHV11, see: ® DHVI11 Technical Manual (Order No. EK-DHV11-TM-001) The DMV11 Synchronous Line Controller The DMVI11 is a high-performance controller that operates at speeds up to 56 kilobytes/second to provide efficient synchronous communications for distributed networks. Point-to-point configurations are practical when terminals have a high mes- sage rate. However, the message rate of the terminals is usually very low, even though the bit rate might be quite high. In those cases, sharing a transmission line can significantly reduce the cost and improve the efficiency of a communications network. You will need to order a base module (DMV11) and one of four cabinet kits. The DMV11 cabinet kit option you choose depends on the interface requirements of your system. 4-24 VAXstation Il/GPX Owner's Manual, BA123 Enclosure NOTE: The RS-232-C standard has been superseded by the ELIA-232-D standard. The four DMV11 cabinet kit options are: 1. CK-DMV11-AA M8053—-M Microcontroller/line unit (a quad-height module with multipoint microcode) H3254 (V.35 or integral modem) Module test connector H3255 (RS-423-A/EIA-232-D) Module test connector BC08S-1K Cable H325 and H3251 Cable turnaround test connector 70-20863-00 3.2 x 2.6 Panel CK-DMV11-BA M8053-M Microcontroller/line unit (a quad-height module with multipoint microcode) H3254 (V.35 or integral modem) Module test connector H3255 (RS-423-A/EIA-232-D) Module test connector BC17E-25 Cable H3250 Cable turnaround test connector 70-20861-1K Panel CK-DMV11-CA M8064-M Microcontroller/line unit (a quad-height module with mul- tipoint microcode) H3254 (V.35 or integral modem) Module test connector 7018250-1K Cable H8568 and H8570 Terminators 70-20862-00 Panel Options 4—-25 4. CK-DMV11-FA e MB8053-M Microcontroller/line unit (a quad-height module with multipoint microcode) | e H3254 (V.35 or integral modem) Module test connector e H3255 (RS-423-A/EIA-232-D) Module test connector e BC08S Cable e H3251 Cable turnaround test connector e 70-20864-00 Panel To order a DMV11 after the initial system installation, contact your sales representative. Contact your service representative to install the DMV11. For more information about the DMV11 synchronous line controller, see: e DMV11 Synchronous Controller User’s Guide (Order No. EK-DMV11-UG) The DPV11 Synchronous Line Controller The DPV11 is a low-cost single-line programmable interface that operates at speeds up to 56 kilobytes/second to provide efficient synchronous communications for distributed networks. The DPV11 is suited for interfacing to medium-speed synchronous lines for The DPV11 is compatible with DIGITAL's family of modems and with the Bell 200 Series modems and remote batch and remote job-entry applications. their equivalents. To order a DPV11 after the initial system installation, contact your sales representative. Contact your service representative to install the DPV11. For more information about the DPV11, refer to the following document: e DPVI11 Technical Manual (Order No. EK-DPV11-TM) 4-26 VAXstation Il/GPX Owner's Manual, BA123 Enclosure The KMV11 Programmable Controller The KMV11 is a high-performance direct memory access single-line programmable communications controller that operates at up to 64 kilobytes/ second to provide efficient synchronous or asynchronous communications for distributed networks. The KMV11 performs user-defined communications functions, thereby freeing the host to do more application computations. The KMV11 can be programmed in synchronous or asynchronous modes. It also provides full modem support for DIGITAL'’s family of modems, the Bell 200 Series or equivalent, and European PPT-approved modems. To order a KMV11 after the initial system installation, contact your sales representative. Contact your service representative to install the KMV11. For more information about the KMV11, refer to the following document: e KMV11 Programmable Communications Controller Technical Manual (Order No. EK-KMV11-TM) Options 4-—27 . S Chapter 5 Troubleshooting Procedure This chapter, divided into three parts, provides troubleshooting information for the VAXstation 1I/GPX: * POWER-UP MESSAGES—discusses the indications that appear when the system is turned on. e BASIC TROUBLESHOOTING—provides a checklist of potential minor problems with the system unit, fixed disk and diskette drives, tape drive, pointing device and monitor, and corrective actions you can take. e MICROVAX DIAGNOSTIC MONITOR (MDM)—describes the VA Xstation II/GPX “MicroVAX Diagnostic Monitor System” (MDM) software tests and the “Main Menu” maintenance options. NOTE: If you have a diskless system that contains neither a TK50 tape drive nor a floppy diskette drive, contact your service representative for additional system troubleshooting and diagnostics. Power-up Messages During the power-up sequence, the VAXstation II/GPX executes built-in diagnostic and bootstrap routines that provide maintenance information. The information is displayed in single letters and numbers on both the lightemitting diode (LED) display, located on the CPU distribution panel on the back of the VAXstation II/GPX system unit, and on the monitor screen. Normally, the display progresses from F to 0 (going from F to A and then 8 to 0). A problem exists if the display stops in the F to 0 range. e If the display stops in the F to 3 range, a hardware error might exist in the VAXstation II/GPX system. Contact your service representative. * If the display stops on A, check the keyboard connection and the pointing device connection. (See Setting Up the Keyboard and Pointing Device section in Chapter 2.) * If the display stops on 2, check the “system does not boot from...” problem indications listed in Table 5-1. e If the display stops on 1, the bootstrap device might not contain bootable system software. Complete the system software installation as directed in the documentation supplied with your system software. Basic Troubleshooting Tables 5-1 through 5-5 list causes and corrective actions for minor system problems that you can fix. The basic troubleshooting procedures are separated into system unit, tape drive, fixed disk and diskette, and monitor problems. If the corrective action does not work or the problem is more serious, run the MicroVAX Diagnostic Monitor (MDM) system software to isolate the problem (see the Maintenance System section of this chapter) and contact your service representative. Monitor fuse replacement instructions and mouse maintenance procedures follow Table 5-5. 5—2 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Table 5—1: System Unit Troubleshooting Procedures Power Up Problem | Possible Cause Corrective Action No response when the power switch is turned System is not plugged in. Set the power switch to 0 (off). to 1 (on). Plug in the system. Set the power switch to 1 (on). Wall outlet is faulty. - Use a different wall outlet. System circuit breaker Set the power switch to off. Reset the circuit breaker by pressing is tripped. down and then pulling up the circuit breaker lever. (See Figure 5-1.) Set the power switch to on. If the circuit breaker trips again, contact your service representative. Figure 5—-1: System Circuit Breaker CIRCUIT ////////”BHEAKEH / MLO-566-85 Troubleshooting Procedure 5—3 Table 5—-1 (Cont.): System Unit Troubleshooting Procedures Power Up Problem Possible Cause Corrective Action No response when the power switch is turned Power cable is incorrectly installed. Set the power switch to off. Check that the cable is fully seated into the socket in the back of the system. Set the power switch to 1 (on). on. Power is on, but the Monitor is off. Turn on the monitor. Monitor cable is incorrectly installed. Make sure that the monitor cable is installed properly. (See Chapter 2.) Brightness and contrast controls are not Adjust brightness and contrast con- display on the monitor does not appear. trols. set properly. Rear panel LED dis- Insert bootable system software disk- play indicates a power- ette. up error. Keyboard cable installed Make sure the keyboard cable is inincorrectly. stalled properly. (See Chapter 2.) A keyboard key or point- Remove anything that may be activating these devices and reboot the ing device pushbutton is accidentally pressed system. during a system boot. Instead of automatically The Halt Enable/Disable switch is set to booting when the power switch is turned the Enable position (the on, the arrow prompt system is set to con- (>>>) is displayed on sole mode). the monitor. when the system di- You failed to insert a system diagnostic medium into the load de- agnostics are running. vice in the time allot- Monitor displays the message ?54 RETRY Type B DUAO and press the Return key to boot the system. Press the Restart pushbutton to re- boot the system. Insert a diagnostic medium. ted. 5—4 Or, exit console mode by setting the Halt Enable/Disable switch to the disable (down) position and then press the Restart pushbutton to have the system boot automatically. VAXstation II/GPX Owner's Manual, BA123 Enclosure Table 5-1 (Cont.): System Unit Troubleshooting Procedures Power Up : Problem Possible Cause Corrective Action System dm not boot The Fixed Disk Ready pushbutton is in, or drive is not ready. Press and release the Fixed Disk System software is not on the disk. Load (install) the system software from the fixed disk drive. Ready pushbutton. on the fixed disk, using the system software installation instructions supplied with the software. System does not boot from the TK50 tape drive. | Fixed Disk Ready push- Press in the Fixed Disk Ready button is not in. pushbutton. Tape is worn or dam- Try another tape. aged. Tape cartridge release System does not boot from the diskette drive. Press down the Vcartridge release handle is not locked. handle. TK50 tape is not fully inserted into the tape Make sure the tape is fully inserted and the cartridge release handle is drive. locked down. Diskette is not in the diskette drive. Insert a diskette containing bootable system software in diskette drive 1 | and enter the applicable boot com- mand for the device. Diskette drive door is Close the diskette drive door. open. Diskette is upside down in the diskette drive. Align the orange stripe on the diskette with the stripe on the diskette drive. Diskette is not bootable. Use a diskette containing bootable system software. Diskette is worn or dam- Try another diskette. aged. Diskette is write pro- Remove the foil tab covering the tected. write-protect notch or use a differ- ent diskette. Troubleshooting Procedure 5—5 Table 5—1 (Cont.): System Unit Troubleshooting Procedures Power Up Problem Possible Cause Corrective Action System does not reboot when power Powerswitch wasnot set in off position for Set power switch to off for at least 15 seconds before pressing to the 1 switch is pressed off enough time. (on) position. Problem Possible Cause Corrective Action System halts unexpectedly during normal operation. The Halt pushbutton Press the Restart pushbutton. Set was pressed (the systhe Halt Enable/Disable switch to tem is in console mode). the disable (down) position to pre- and on. System Halts vent unwanted recurrences. Table 5—-2: Fixed Disk and Diskette Drives Troubleshooting Procedures Read and Write Errors Problem Possible Cause Corrective Action Fixed disk read error message is displayed. Fixed Disk Ready pushbutton is in. Press and release the Fixed Disk Ready pushbutton. Disk is write protected. (Write-Protect pushbut- Press and release the Write-Protect pushbutton so it does not glow. ton glows orange) Fixed disk write error message is displayed. Disk is write protected. Press and release the Write Protect pushbutton. Diskette read error mes- The diskette drive is sage is displayed. empty. Insert a diskette into the diskette drive. Diskette drive door is Close the diskette drive door. open. Diskette is upside down Align the orange stripe on the diskin the diskette drive. ette with the stripe on the diskette drive. 5—6 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Table 5—2 (Cont.): Fixed Disk and Diskette Drives Troubleshooting Procedures Read and Write Errors Problem Possible Cause Corrective Action Diskette is not format- Use a preformatted RX50 diskette. ted. Diskette is worn or dam- Try another diskette. aged. Diskette write error The diskette drive is message is displayed. empty. Diskette drive door is Insert a diskette in the diskette drive. Close the diskette drive door. open. Diskette is upside down Align the orange stripe on the disk- in the diskette drive. ette with the stripe on the diskette drive. Diskette is not format- Use a preformatted RX50 diskette. ted. Diskette is worn or dam- Try another diskette. aged. Diskette is write protected. Table 5—-3: Remove the foil tab covering the write-protect notch. Tape Drive Troubleshooting Procedures Problem Possible Cause Corrective Action TK50 passes the power- Tape is not in the drive, up test but does not Insert the tape and press the Load/ or the drive is not work. Unload pushbutton. loaded. Load/Unload pushbut- Press the Load/Unload pushbut- ton is out. ton. TK50 Load/Unload red A problem exists with indicator flashes rapidly Press the Load/Unload pushbutton the tape drive. and no unusual sounds are heard. four times. If the problem persists, ~ do not attempt to use the tape drive or to remove the tape cartridge. Call your service representative. Troubleshooting Procedure 5—7 Table 5—3 (Cont.): Tape Drive Troubleshooting Procedures Problem Possible Cause Corrective Action Load/Unload indicator flashes rapidly and you Leaders are not properly coupled. Immediately turn off the system by pushing the on/off switch to 0 (off). Do not attempt to use the tape drive or to remove the tape cartridge. hear a whirring sound. Call your service representative. Tape cartridge release The power-up test is Wait for the Load/Unload indicator handle does not lift. still in process. to stop glowing and the Tape Activity indicator to glow green. Try again. If the problem persists, call your service representative. System power is not Turn on the system power. on. Tape cartridge release handle does not lock. Tape is not inserted properly. Reinsert the tape cartridge. If the problem persists, call your service representative. Tape does not unload. The Load /Unload push- Make sure the Load/Unload pushbutton is in the unload position. button is in load position. Table 5—4: Wait for the indicator to go out before trying to remove the tape. Monitor Troubleshooting Procedures Problem Possible Cause Corrective Action Power indicator on the Power cord is not con- front of the monitor nected to the monitor or the wall outlet. Connect the power cord to the monitor and wall outlet. does not light green when you turn on the monitor. 5—8 Monitor is not turned Turn on the system and then the on. monitor. No power exists at the wall outlet. Use another outlet. Monitor fuse is blown. Replace the fuse. See the Replacing the Fuse section. VAXstation Il/GPX Owner's Manual, BA123 Enclosure Table 5-4 (Cont.): Monitor Troublesl ooting Procedures Problem Possible Cause Corrective Action Screen is blank and power indicator on the front of the monitor is lit. System’s CRT saver fea- Press any key to reactivate the disture is activated. play. Screen goes blank after successful power up, and the power indi- Monitor fuse is blown. Replace the fuse. See the Replacing the Fuse section. cator on the front of the monitor goes out. Screen displays raster, Signal cable is discon- Secure the video cable connection but no cursor or text nected. between the monitor and the system. appears. System is not on. Turn on the system. Contrast control is set Turn up the contrast control. to minimum. Host system’s CRT saver Press any key to reactivate the dis- Screen display is distorted, rolling or flickering, or the wrong feature is activated. play. Video cable is incor- rectly installed. Make sure that the video cable is installed properly. Electromagnetic interference exists. seconds. After 30 seconds, recheck color appears. For the color monitor, color is not even; poor color purity. Press the degauss switch for a few purity. Move any electromechanical device away from the monitor or move the monitor. CAUTION: Before moving the monitor, turn the monitor off and wait 30 seconds to allow static electricity on the CRT to discharge. Troubleshooting Procedure 5—9 Table 5-5: Pointing Device Troubleshooting Procedures Problem Possible Cause Corrective Action Mouse does not track The tracking ball is Clean the tracking ball. properly. dirty. Mouse Maintenance section. Pointing device indi- Cable is installed incorrectly. Unplug and then replug the cable O cator does not appear on the monitor screen, or the monitor does to reset the device. See the (See Chapter 2) not respond to the pointing device commands. Replacing the Fuse If the Monitor Troubleshooting Procedures (Table 5-4) indicate that you need to replace the fuse for the monitor, follow the instructions. Color Monitor The color monitor has an automatic voltage-switching mechanism. Therefore, you do not need to change the voltage switch setting. Use either of the following fuses: e 3AG, a 2-Amp, 250-volt, slow-blow fuse. (DIGITAL part number: 12- (DIGITAL part number: 12— 14676-04) e IEC, a 2-Amp, 250-volt, slow-blow fuse. 19283-03) 5—10 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Figure 5—2: Fuse Location, Color Monitor POWER CORD L~ CONNECTOR POWER SWITCH | VIDEO CABLE < | ASSEMBLY TO WALL OUTLET MLO-872-85 To replace the fuse: 1. Turn off the power and wait 10 seconds to allow the voltage to dissipate. WARNING: You must wait a full 10 seconds or the voltage may harm you. 2. Unplug the power cord from the wall outlet and then from the monitor. Troubleshooting Procedure 5—11 3. Carefully pry out the fuse carrier with a screwdriver. FUSE POWER CORD / CONNECTOR POWER SWITCH VIDEQ CABLE ASSEMBLY s | } RELEASE TA S ® J L MLO-868--86 Carefully pry open the release tab, remove the inner fuse holder, and W Replace the inner fuse holder in the fuse carrier. o Replace the fuse carrier in the back of the monitor. N | Plug the power cord back into the monitor and then into the wall outlet. ® replace the fuse. Turn on the power. 5—12 VAXstation Il/GPX Owner's Manual, BA123 Enclosure Mouse Maintenance The rubber-coated ball under the mouse can be removed for cleaning or replacement. Clean the ball when the mouse fails to smoothly move the cursor on the screen. In an average office environment, cleaning the ball every 6 months is sufficient. To remove and clean the mouse ball:; 1. Turn the mouse upside down. Remove the ball housing cover plate by placing your fingers in the grooves on the plate and turning the plate counterclockwise. | MLO-B6BA-88 Troubleshooting 2. Lift off the cover plate and remove the ball. MLO-568B-85 3. Clean the ball with lukewarm water and, if necessary, a mild soap. CAUTION: Do not use organic solvents such as toluene or trichlorethane, which will damage the rubber coating. 4. Dry the ball with a soft, lint-free cloth. 5—14 VAXstation |I/GPX Owner's Manual, BA123 Enclosure 5. Replace the ball and cover plate. MLO-568E-85 Troubleshooting 6. Lock the cover plate into position by placing your fingers into the grooves on the cover plate and turning it clockwise. MLO-588F-85 5-16 VAXstation II/GPX Owner's Manual, BA123 Enclosure MicroVAX Diagnostic Monitor The ‘"MlmoVAX Diagnostic Monitor” (MDM) system software provides user tests that isolate and identify faults in the system. Use this software to test the system in response to an error message or to test your system perlodlcally Test the system (and record the results) before calling your service representative. In addition, the maintenance software displays list system utilities and system devices. The maintenance software is stored on RX50 diskettes or on a TK50 cartridge. To run the maintenance programs and to call VAXstation II/GPX system displays, use the monitor and keyboard for command inputs. The MicroVAX Diagnostic Monitor Main Menu The “MicroVAX Diagnostic Monitor Main Menu” display lists the testing options. See the Checking the System section of Chapter 2 for instructions on accessing the “Main Menu.” Press the RETURN key to continue. > MAIN MENU 1 -- Test the system 2 -- Display System Configuration and Devices 3 -- Display the System Utilities Menu 4 -- Display the Service Menu 5 -- Exit MicroVAX Diagnostic Monitor Type the number; then press the RETURN key. > The following maintenance system options appear in the “Main Menu” in the previous picture: ® 1—Test the System. This option tests the devices supplied by DIGITAL for a VAXstation II/GPX system. See the Checking the System section of Chapter 2 for instructions on testing devices. Troubleshooting Procedure 5-—17 e 2—Display System Configuration and Devices. This option displays a list of the devices supphed by DIGITAL for a VAXstation II/GPX system. A sample screen is shown in the following illustration. Your configuration might be different from this example. Type the number; then press the RETURN key. >2 SYSTEM CONFIGURATION AND DEVICES SYSTEM CONFIGURATION CPUA. . .MicroVAX CPU KA630-AA 1MB, FPU MOO HOO MEMA. . .MicroVAX memory system 2 megabytes, 4096 Pages. KA630. ..CPU module, 1MB on-board memory. MS630-AA.. .Dual height memory module, 1MB. RQDXA. . .Winchester/diskette controller. Revisions=10 and 6 ...cannot identify drive, RX50. . .Removable Offline. RX50. . .Removable DEQNAA. . .Ethernet controller. O0B-00-2B-02-17-D3 VCBO2A. . .Graphics Processing Extension Press the RETURN key to return to the previous menu. > NOTE: The last letter in each device listed differentiates among multiple devices of the same type. For example, DEQNAA indicates one DEQNA module; DEQNAB a second, and so forth. NOTE: When you have two of the 8-megabyte memory options (MS630-CA) installed, you receive a message that the 1-megabyte of memory on-board the CPU is disabled. This message does not indicate an error. VAXstation II/GPX systems have a 16-megabyte limit on physical memory. ® e 3—Display the System Utilities Menu, which allows you to format your fixed disk. | | 4—Display the Service Menu. This option displays the Field Service diagnostics. Only your service representative should use this menu. (See the VAXstation Maintenance Guide for additional information.) * 5—Exit MicroVAX Diagnostic Monitor. from the “Diagnostic Monitor”. 5—-18 This option allows you to exit VAXstation I/GPX Owner's Manual, BA123 Enclosure The System Utilities Menu ~ The only option in this menu is the Customer Disk Drive Formatter. This option allows you to format a fixed disk or a diskette. Your fixed disk or diskette must be formatted before you can use it to store data. CAUTION: Formatting a fixed disk or diskette destroys all data on the disk or diskette. Use the formatting utility only if you have made copies of any data on the disk you want to save or the disk is empty. To format a system fixed disk or a diskette in the diskette drives with the screen displaying the System Utilities screen: 1. Type 1 and press the RETURN key. 2. If you are formatting a fixed disk you are prompted to write-protect all the drives except the one you want to format. Push the write-protect pushbutton to make sure that it is in the out (write-enable) posntmn on the drive control panel. If you are formatting a diskette, remove the write-protect foil tab on the diskette and insert the diskette into the diskette drive. Press the RETURN key. The screen displays a list of the drives and their unit numbers and prompts you for the number of the unit (drive) you want to format. Type the number of the unit and press RETURN. You are asked to verify the unit number. If the unit number is correct, type 1 and press the RETURN key. If the unit number is incorrect, type 0 and enter the correct unit number. The screen displays status messages as the formatting continues and informs you when the formatting process is complete. Troubleshooting Procedure 5—19 — Chapter 6 Service If you are unable to correct a problem with your VAXstation II/GPX system, contact your service representative. How to Call for Service Before you call: 1. Check the problem-solving suggestions listed in Chapter 5. You can often solve a problem yourself. 2. Write down the serial and model numbers of your VAXstation II/GPX. The numbers are located on the rear panel of the system unit (and on the service tag on system front panel). 3. Summarize the problem. Make a note of what you were doing when the system failed. Note if any indicators turned on or off, or if you heard any new sounds before or after the system failed. Who you call: 1. Call your service representative. If you are under warranty or have a DIGITAL service contract, you may also call the customer support center for assistance. In the United States, the customer support hot line number is 1-800-DEC-8000. If you are located outside the United States, contact your sales representative for the local service branch office phone number. Service 6-—1 When you call: 1. Stay near the VAXstation II/GPX. 2. Have all your materials available (for example, manual, serial and model numbers, and problem summarization). That will assist the service representative with helping you. NOTE: If you return the VAXstation 1I1/GPX to DIGITAL for service, repack the system or modules in their original shipping containers. DIGITAL Services Your DIGITAL hardware warranty gives you access to DIGITAL's best resources, including technical expertise, spare parts inventories, and worldwide service. After warranty, DIGITAL'’s support continues through optional on-site and off-site services for as long as you own your DIGITAL hardware. DIGITAL's on-site services include fast response time and full support, including the cost of parts and labor. Contact your service representative for a description of the DIGITAL services available in your area. 6—2 VAXstation II/GPX Owner's Manual, BA123 Enclosure Appendix A VA Xstation 11/GPX System Specifications Table A-1: Input System Electrical Requirements | Specifications’ 120 V ac 220 V ac Voltage range 88-128 V 176-256 V Power source phasing single single Frequency 60 Hz 50 Hz 47-63 Hz 47-63 Hz Running current (typical) 8.8 A 4.4 A Power consumption (maximum) 690 W 690 W Line frequency range | 1These requirements depend on the line voltage setting that you select. VAXstation II/GPX System Specifications A—1 System Environmental Requirements Table A—-2: Operating Nonoperating Maximum altitude 2400 m 12000 m Temperature range’ 15-32 deg. C -40-60 deg. C (60-90 deg. F) (-40-140 deg. F) 20%-80% 10%-95% | Relative humidity IReduce the maximum temperature specification by 1.8 degrees Celsius (3.24 degrees Fahrenheit) for each ' 1000-meter increase in altitude. NOTE: Your service contract may require limits for temperature and humidity that override the limits listed above. Color Monitor Specifications Table A—-3: Description | Characteristics Physical Height Width Depth Weight 47 cm (18.5 in) 51.8 cm (25 in) 54.6 cm (21.5 in) Approximately 41 kg (90 1b) Picture Tube Size Diagonal 480 mm (19 in) viewable Video Format RGB color, composite video Display Characteristics 0.31 mm dot pitch with high efficiency antiglare treatment 1024 x 864 pixels, giving approximate picture size of 326 x 275 mm Timing Vertical rate Horizontal rate A—-2 60 Hz 54 KHz VAXstation Il/GPX Owner's Manual, BA123 Enclosure Table A-3 (Cont.): Color Monitor Specifications Description Characteristics Video R and B Input Signals 0.7 V pp/75 Ohm Video G Composite Signal 1V pp/75 Ohm Power AC input 88-132 V, 50/60 Hz 185-264 V, 50 Hz Power consumption 150 W (nominal) Fuse (either may be used) 2A, 250 V slow blow (3AG) DIGITAL part no. 12-14676-04 2A, 250 V slow blow (IEC) (European designation T2A-250 volt) DIGITAL part no. 12-19283-03 External Controls Contrast Brightness Degauss Tilt-lock lever On/off Operating Temperature Range 10-40 deg. C (50-104 deg. F) Humidity 10%-95% relative humidity, noncondensing VAXstation II/GPX System Specificatigns A—3 Table A—4: Description Mouse Specifications Characteristics Physical Height 4 cm (1.57 in) Diameter 8.8 cm (3.47 in) Weight 0.82 kg (0.37 1b) Cable 1.5 m (5 ft) in length, 0.38 cm (0.15 in) diameter, six conductors, shielded, high flexibility design Connector 7-pin Micro-DIN type (male) Temperature Operating Nonoperating 10-40 deg. C (50-104 deg. F) -40-66 deg. C (-104 deg. F-140 deg. F) Electrical Power Interface +5 V +/-5% at 130 mA -12 V +/-10% at 20 mA (serial) RS-232 voltage level compatible TTL compatible FCC/EMI A—4 Class B certified VAXstation II/GPX Owner's Manual, BA123 Enclosure Table A—4 (Con Description t.): Mouse Specifications Characteristics Performafice Resolution 79 counts/cm 250 counts/in Tracking speed 73.5 cm/sec (30 in/sec) Accuracy +/-3% 0-24.5 cm/sec (0-10 in/sec) any direction +/-15% 24.5-49 cm/sec (10-20 in/sec) any direction +/-30% 49-73.5 cm/sec (25-30 in/sec) any direction Operating Modes Incremental Stream Prompt Data format Delta Binary Sampling rate 55 reports/sec in incremental stream mode, up to 95 reports/sec when polling Baud rate 4800 baud Pin assignments Pin 1 Function ground 2 transmit data 3 receive data 4 -12V 5 +5V 6 not used (+12 V) 7 not used shell protective ground Table A-5: Description Tablet Specifications Characteristics Physical Construction Molded, high-impact plastic Finish Fine matte finish to minimize glare and fingerprints Color Light gray VAXstation 1I/GPX System Specifications A—5 Table A-5 (Cont.): Description Power/signal cable Tablet Specifications Characteristics 1.5 m (5-foot) cable wired to tablet, terminated in a 7-pin Micro-Din connector Height 2 cm (0.8 in) Width 41.2 cm (16.2 in) Length 40.6 cm (16 in) Weight 3.2 kg (7 1b) Performance Resolution 79 counts/mm 250 counts/in Active area 279 mm x 279 mm (11 in x 11 in) Proximity 1.27 cm (0.5 in) cursor (Nominal) 0.63 cm (0.25 in) stylus Interfaces Serial, asynchronous, full-duplex, with R5232C signal levels Sampling Rate 55, 72, or 120 pairs/sec Data Rate 4800 or 9600 baud (software selectable) Coding Binary 5-byte format. The first byte contains synchronization, pushbutton status, and proximity information. Second and third bytes have absolute X coordinate positions. The fourth and fifth bytes have absolute Y coordinate positions. Each byte is found by one start bit and one stop bit. The data byte contains 8 bits of data and 1 bit for parity (odd parity). Coordinate origin Lower left corner of active area Operating Modes - Remote request Incremental Diagnostics X-Y coordinate update and proximity report when polled by host Position reports are generated as long as cursor is in motion. Reports are also generated when the pushbuttons are pressed or released. Built-in diagnostics that check electronics, communication, tablet, and transducers A—6 VAXstation 1I/GPX Owner's Manual, BA123 Enclosure Table A-5 (Cont.): Tablet Specifications Descriptidn Characteristics Interface | o Description EIA RS232C compatible signals Power requirements +12 Vdc +/-10% at 0.3 A Output connector (Power and Data) 7-Pin Micro-Din (male) Mating connector 7-Pin Micro-Din (female) Pin assignments 7 Pin (RS232C) "o \;a\m#wnfiag Function signal and power signal Table A—-6: transmit data (from tablet) receive data not used not used +12V tablet present RD53 Fixed Disk Drive Specifications Description Characteristics Storage Total capacity 71,303,168 bytes User capacity 70,987,776 bytes 138,648 blocks User capacity Performance! Average seek time 30 msec Average rotational latency 8.33 msec Average access time 38.33 msec Transfer rate 184.32 kb/sec Physical Height 8.25 cm (3.25 in) Width Depth 20.32 cm (8 in) Weight 3.18 kg (7 1b) 14.6 cm (5.75 in) 1When operating with RQDX3 controller VAXstation |I/GPX System Spec A-7 Table A-7: RDb54 Fixed Disk Drive Specifications Description Characteristics Storage Total capacity 191 mbytes User capacity 159 mbytes User capacity 310,550 blocks Performance! Average seek time 30 msec Average rotational latency 8.33 msec Average access time 38.3 msec Transfer rate 5 mb/sec Physical Height 8.255 cm (3.38 in) Width 14.60 cm (5.75 in) Depth 20.32 cm (8.20 in) Weight 2.8 kg (6.3 1b) 1When operating with RQDX3 controller Table A—-8: RX50 Dual Diskette Drive Specifications Description Characteristics Medium Diskettes /RX50 drive—2 Recording surfaces/ diskette—1 Storage capacity Per diskette (80 tracks) 409,600 bytes Per track (10 sectors) 5120 bytes Per sector (1 logical block) 512 bytes Performance! Average seek time 164 msec Average rotational latency 100 msec Average access time 264 msec Transfer rate 12.8 kb/sec 1When operating with RQDX3 controller A—8 VAXstation II/GPX Owner's Manual, BA123 Enclosure Table A-8 (Cont.): RX50 Dual Diskette Drive Specifications Description Characteristics Physical Height 8.5 cm (3.25 in) Width Depth 14.6 cm (5.75 in) 21.6 cm (8.50 in) Weightr 2.8 kg (4.18 1b) Table A-9: TK50 Tape Drive Specifications Description Characteristics Medium Magnetic tape Dimensions 1.27 cm (0.5 in) wide 183 m (600 ft) long Mode of operation Streaming Read/Write method Serpentine Recording density 16,934 bits/cm (6667 bits/in) Number of tracks 22 Capacity Unformatted 131 mb Formatted 94.5 mb Performance Tape start time Tape speed 190.5 cm/sec (75 in/sec) Streaming data rate 500 kb/sec Access time 1 min minimum (from insertion of a new 35 min maximum tape) Physical Height 8.25 cm (3.25 in) Width 14.60 cm (5.75 in) Depth 21.44 cm (8.44 in) Weight 2.27 kg (5 Ib) VAXstation II/GPX System Specifications A—9 S g, Appendix B VAXstation II/GPX Related Documents This appendix lists and describes documents pertaining to a VAXstation II/ GPX system in the BA123 enclosure. The first section deals with hardware. Sections on ULTRIX software and MicroVMS software follow. Refer to the software section applicable to your system. Each software section lists both operating system and workstation documentation. The last page of this book provides information on ordering documentation. Hardware BA123 Site Preparation and Verification Guide (Order No. EK-BA123-SP) provides planning information for system installation. The guide contains space, power, and environmental suggestions. VCBO02 Video Subsystem Technical Manual (Order No. EK-104AA-TM) describes the operation and programming of the VCB02 module. The manual is packaged in the same binder as this book. MicroVAX II Maintenance Kit (Order No. ZNABX-GZ) VR290 Color Video Monitor Installation/Owner’s Guide (Order No. EKVR290-IN) describes how to install, operate, and troubleshoot the color monitor. Mouse Installation Sheet (Order No. EK-VSXXA-IN) explains how to set up the mouse. Tablet Installation Guide (Order No. EK-VSXXB-IN) explains how to set up the tablet. KA630-A CPU Module User's Guide (Order No. EK-KA630-UG) details the internal operation of the MicroVAX KA630-A CPU. VAXstation II/GPX Related Documents B—1 MicroVAX II Maintenance Information Kit (Order No. ZNA3X-C3) explains how to service systems. ULTRIX Software ! ULTRIX-32m Documentation Kit Overview (Order No. AV-CN33C-TE) describes the ULTRIX-32m documentation set. You may order the entire ULTRIX-32m documentation set as a unit (Order No. QZ832-GZ). ULTRIX-32m Release Notes (Order No. AA-CN34C-TE) contains information about last-minute changes to the software and documentation. ULTRIX-32m Installation Guide (Order No. AA-CN29C-TE) describes the ULTRIX-32m operating system installation procedure for a system that includes a MicroVAX processor. ULTRIX-32m System Manager’s Guide (Order No. AA-CN28C-TE) con- tains information for the person responsible for operation and care of a system running ULTRIX-32m. ULTRIX-32m Programmer’s Manual Section 1 (Order No. AA-CN25C-TE) describes the commands accessible to all system users. ULTRIX-32m Programmer’s Manual Section 2 and 3 (Order No. CN26C-TE) explains systems calls and subroutines of interest to system programmers. ULTRIX-32m Programmer’s Manual Section 4, 5, 7, and 8 (Order No. CN27C-TE) describes special system files, file formats, macro packages and conventions, and system maintenance commands. ULTRIX-32m Master Index (Order No. AA-CN36C-TE) allows fast access to information in the ULTRIX-32m documentation set. Individual indexes are included in each book. | ' ULTRIX-32m Supplementary Documents Volume I (Order No. AA-CN30ATE), ULTRIX-32m Supplementary Documents Volume II (Order No. AA- CN31B-TE), and ULTRIX-32m Supplementary Documents Volume III (Order No. AA-CN32A-TE) contain articles about various components of the ULTRIX system. Programmers who designed the components wrote these articles. Some of the material in these volumes may be partially ! These documents pertain only to customers in the United States. If you are not a U.S. customer or if you require translated documents, check the appropriate country’s product listing. B—2 VAXstation Il/GPX Owner's Manual, BA123 Enclosure inaccurate or dated. These articles are provided to augment the refer- ence and task-oriented information contained in the other ULTRIX-32m documentation. ULTRIX-32w Documentation Kit Overview lists the ULTRIX-32w documentation set. You may order the entire ULTRIX-32w documentation set as a unit (Order No. 00-Q4X32-GZ). ULTRIX-32w Technical Summary (Order No. AA-GT87A-TN) describes the architecture, concepts, and nomenclature of the workstation software. ULTRIX-32w Installation and Management Guide (Order No. AA-GT88ATN) discusses the installation and management of the workstation software subsets. Using and Customizing the Window Manager (Order No. AA-GT89A-TN) introduces the new user to the ULTRIX workstation environment. The manual describes how to use the window system and how to change the environment to suit the user’s needs. ULTRIX-32w QDSS/VCBO02 Driver Reference (Order No. AA-GT90A-TN) describes the ULTRIX kernel services that support the QDSS and other VAXstation II/GPX system hardware. The manual outlines device driver support of the VAXstation hardware and specifies the various driver services. ULTRIX-32w QDSS Interface Library Programming (Order No. AA- GT91A-TN) describes the optional ULTRIX C language library routines and macros that allow direct access and control of the QDSS/VCB02 graphics subsystem. The guide is intended for software engineers who are writing applications and need the performance afforded by direct access to the QDSS hardware. ULTRIX-32w Xlib Programming Reference (Order No. AA-GT92A-TN) describes the architecture, nomenclature, and C language interface of the ULTRIX application or window server and the terminal emulators. This provides a complete reference to the X window server C library, which supplies program control over text, graphics, window, and client applications. | ULTRIX-32w GKS/0b Programming (Order No. AA-GT93A-TN) describes the operating system implementation of VAX GKS/0b. The guide dis- cusses the program environment and the workstation specifics for QDSS, LNO1, and X server. The guide also provides a reference to the C and FORTRAN (f77) GKS calls. VAXstation 1I/GPX Related Documer ULTRIX-32w Services Reference (Order No. AA-GT94A-TN) includes descriptions of important programs and subsystems. This section can either be used separately, or individual pages can be inserted in the user’s operating system Programmer’s Manual. C Language X Interface (Order No. AA-HF10A-TN) describes the X window system software. Two contributors to the X window software wrote the paper. ULTRIX-32m Master Index (Order No. AA-CN36C-TE) allows fast access to information in the ULTRIX-32m documentation set. Individual indexes are included in each book. MicroVMS Software MicroVMS Release Notes (Latest Version) contains last-minute information about MicroVMS. You may order the entire MicroVMS documentation set as a unit (Order No. 00-QZ001-GZ-4.4). MicroVMS User’s Primer (Order No. AAmZZlOCmTE) introduces the MicroVMS operating system to novice users. MicroVMS User’s Manual (Order No. AA-Z209B-TE) describes the operation of the MicroVMS operating system. MicroVMS User’s Pocket Reference (Order No. AA-Z211C-TE) summarizes the DIGITAL Command Language (DCL), EDT editor, DIGITAL Standard Runoff (DSR), and MAIL commands. MicroVMS FORTRAN Programmer’s Primer (Order No. AA-Z213A-TE) contains concepts of program development using FORTRAN in the MicroVMS environment. MicroVMS FORTRAN Programmer’s Manual (Order No. AA-Z212B-TE) contains guidelines for using VAX FORTRAN with MicroVMS tools, such as run-time library routines, system services, the debugger, and relevant utilities. The manual presents a task-oriented approach to programming with FORTRAN on a MicroVMS system. Specifications for VAX FORTRAN statements are included in an appendix. MicroVMS Programming Support Manual (Order No. AA-DC87B-TE) contains the specifications for the following MicroVMS programming support tools: the run-time library routines, system services, terminal and mailbox I/O function codes, debugger, linker, file definition language, message utility, command definition utility, and condition codes. B—4 VAXstation |I/GPX Owner's Manual, BA123 Enclosure MicroVMS Programming Pocket Reference (Order No. AA-Z214B-TE) contains syntax specifications for the following programming tools: run-time library routines, system services, debugger commands, and relevant DCL commands. The pocket reference also includes a summary for dot notation. MicroVMS Workstation User’s Guide (Order No. AA-EZ24C-TN) describes the installation and use of the MicroVMS workstation software. You may order the entire MicroVMS workstation documentation set as a unit (Order No. 00-Q4A96-GZ-3.0). MicroVMS Workstation Graphics Programming Guide (Order No. AL- GL10B-TN) provides a tutorial and a reference to the MicroVMS workstation graphics programming interface. MicroVMS Workstation Video Device Driver Manual (Order No. AADY65D-TE) contains information about device drivers for programmers. The section on the VCB02 (QDSS) applies to the VAXstation II/GPX. VAXstation Il/GPX Related Documents B—5 AR S I Glossary application program A program designed to perform a task, such as monitoring a manufacturing process. ASCII American Standard Code for Information Interchange. A set of 8-bit binary numbers representing the alphabet, punctuation, numerals, and other special symbols used in text representation and communications protocol. asynchronous multiplexer A device that provides asynchronous communication and brings together several low-speed communications channels. The device controls and alternates the transmission of signals with start and stop signals, so that more than one signal can be transmitted over a single communications line. backplane A connector block that connects modules through a bus and provides physical support of those modules. back-up copy A copy of data stored on your disk. The duplicate copy is stored on either RX50 diskettes or TK50 magnetic tape cartridges. back-up process The process of making copies of the data stored on your disk so that you can recover that data after an accidental loss. You make back-up copies on RX50 diskettes or TK50 magnetic tape cartridges. baud rate ‘ The speed at which signals are serially transmitted along a communications line. One baud equals one bit/second. bezel A cover used to hold and position the edges of a device. Glossary-1 binary A number system that uses 2 digits: 0 and 1. They are represented in system circuitry by two voltage levels, and the system programs are executed in binary form. | bit A binary digit; the smallest unit of information in a binary system of notation, designated as a 0 or a 1. bitmap The type of graphics supported by the VAXstation II/GPX. With bitmap graphics, the workstation software can individually access each dot (pixel) on | the video screen. boot See bootstrap. bootable medium A fixed disk, diskette, or magnetic tape cartridge containing software (such as an operating system), that a bootstrap program can load into the system memory and begin program execution. bootstrap A program that you start when you turn on the system. The bootstrap 1. loads software contained on fixed disk, diskette, or magnetic tape car- tridge into memory; the system stops executing the bootstrap and starts executing the software in memory. The software usually loads an oper- ~ ating system or other software into memory so that the system can start processing. 2. To use a bootstrap program. bus A printed circuit module that is part of the backplane. The bus permits the sharing of signals among the system modules. byte | | A group of eight binary digits (bits). A byte is one-quarter of the size of a system word. Glossary-2 Central Processing Unit (CPU) The part of the system that controls the interpretation am,d execution of instructions. In the VAXstation II/GPX system, CPU functions are contained on one MicroVAX II CPU chip. command An order you can give to the system, often through a terminal keyboard. communications line A cable along which electrical signals are transmitted. Devices or systems that are connected by a communications line can share information and resources. computer system A combination of system hardware, software, and external devices that performs operations or tasks. console mode The stage at which a device can communicate directly with the CPU. For the VAXstation II/GPX, console modeis activated by pressing the halt pushbutton when the Halt Enable/Disable switch is enabled (up) and is indicated by the arrow prompt (>>>) on the system monitor. controller A system component, usually a printed circuit module, that regulates the operation of one or more peripheral devices. Controllers are often called interface units. control panel The panel on the front of the system cabinet that contains control switches and indicator lights. CPU Abbreviation for Central Processing Unit. See Central Processing Unit. CRT (Cathode Ray Tube) A vacuum tube that generates and guides electrons onto a fluorescent screen to produce characters or graphics. A term often used to refer to a monitor. data | A representation of facts, concepts, or instructions in a formalized manner suitable for communication, interpretation, or processing by humans or by automatic means. Glossary-3 | data transmission The movement of data in the form of electrical signals along a communications line. debug To detect, locate, and correct errors (bugs) in system hardware or software. DECnet DIGITAL communication network. device The general name for any unit connected to the system that is capable of receiving, storing, or transmitting data. See input device, output device, Input/ Output device, and controller. device name | The name by which a device or controller is identified in the system. You use that name to refer to that device when you are communicating with the system. diagnostic medium Diskette or tape that contains diagnostics. See diagnostics. diagnostics A program that detects and identifies abnormal system hardware operation. The VAXstation II/GPX “Maintenance System” software contains several diagnostic programs. disk A flat circular plate with a coating on which data is magnetically stored in concentric circles (tracks). The VAXstation II/GPX contains at least one fixed disk, either the RD53 or RD54 disk drive subsystems, or both. disk drive A device that holds a fixed disk. The drive contains mechanical components that spin the disk and move the read/write heads that store and read information on the surface of the disk. The VAXstation II/GPX disk drive can read and write on the RD53 and RD54 fixed disks. disk drive subsystem A free-standing disk drive that provides additional storage for the system. The RD53 and RD54 are disk drive subsystems that can be added to the VAXstation II/GPX. Glossary-4 diskette A flexible, floppy disk contained in a square paper envelope. The VAXstation I1/GPX uses the RX50 13.13-centimeter (5.25-inch) diskettes. diskette drive A disk drive that only reads or writes on removable diskettes. The VAXstation II/GPX diskette drive uses RX50 diskettes. A method of generating characters for printing that uses dots to produce readable characters. down-line load To send a copy of a system image or other file over a line to the memory of a target node. error message A message displayed by the system to indicate a mistake or malfunction. file A collection of related information treated by the system as a single item. formatted data A pattern of data that conforms to a predetermined structure dictated by the system software. - GKS Graphics Kernel System. GKS acts as one of the graphics interface for the VAXstation 1I/GPX. GPX Graphics Processing Extension. hard-copy terminal A terminal that displays information on paper. Compare to video terminal. hardware The physical components—mechanical and electrical—that make up a system. Compare to software. head The part of a fixed disk drive, diskette drive, or tape drive that reads, records, and erases data. Also called read/write head. Glossary-5 host The primary or controlling computer in a multiple computer network. input device A piece of equipment that is used to transfer data to the system. For example, a keyboard is an input device. y Input/Output (I/0) device A piece of equipment that accepts data for transmission to (input) and from (output) the system. For example, a terminal. interactive The method of communicating with the system. You type a command at the keyboard. The system executes the command and responds with a prompt character for another command. interface A device or piece of software that allows the components of the system to communicate, /0 Abbreviation for Input/Output. See Input/Output (I/0) device. K The symbol that means 2 to the 10th power (or 1024 in decimal notation). kilobyte 1000 bytes. LED Light-Emitting Diode. LEDs are used as indicators on the control panel. A segmented LED display on the CPU distribution panel insert on the back of the VAXstation II/GPX cabinet displays the characters F-A and 8-0 during the power-on sequence to indicate CPU status and normal/abnormal operation. load 1. To move software (usually from a peripheral device) to memory. 2. To physically place a disk on a disk drive or a tape on a tape drive. Glossary-6 Local Area Network (LAN) A data communications system designed for a small geographic area that offers hxghwspeed communications channels optimized for connecting information processing equipment. For example, Ethernet. M The symbol for 1024 squared (1,048,576 in decimal notation). magnotid tape A strip of plastic coated with magnetic oxide and used for storing data. Often called magtape. megabyte 1,000,000 bytes. memory The area of the system that holds the instructions and data that temporarily store information. memory module A logic circuit module that contains additional memory for the system. Two memory modules with 1, 2, or 4 megabytes of memory can be added to the VAXstation I1/GPX. menu A displayed list of options that you can select to run. MicroVAX Workstation Any workstation based on the 32-bit MicroVAX CPU. The workstations include the MicroVAX and the VAXstation systems. MicrovMS A micro version of the VAX/VMS operating system for MicroVAX-based systems. MicroVMS enables installation of only those parts of the VMS operating system you require, but will allow access to all VMS operations. MicroVMS Workstation Software Window management software for a MicroVAX-based system. must run MicroVMS as the operating system. The system Workstation software allows you to control and view several programs on one screen. window with which to interact by using a pointing device. You specify the Glossary-7 module A printed circuit board. The module contains chips, electrical components, and electrically conductive pathways between components. A module stores data or memory, or controls the functions of a device. mouse A relative-positioning input device that is rolled across the desktop to move the cursor on the monitor screen, and is used to select menu options and draw graphics. The mouse is palm-sized, contains three pushbuttons (function keys), and a ball bearing. The mouse is a pointing device for the VAXstation II/GPX. network A group of individual computer systems that are connected by communications lines to share information and resources. node An individual information-processing unit, such as a computer, workstation, or peripheral device, that is connected to a network. off-line Pertaining to equipment, devices, and events that are not controlled by the system. on-line Pertaining to equipment, devices, and events that communicate with. the system. operating system A collection of system programs that control the operation of the system and perform such tasks as assigning memory to programs and data, processing requests, scheduling jobs, and controlling the operation of input and output devices. output device A device that extracts data from the system. A printer is an example of an output device. peripheral device A device that provides the CPU with additional memory storage or commu- nication capability. Examples are disk and diskette drives, video terminals, and printers. Glossary-8 plane | Measures 1K x 1K x 2K and holds a total of 256K memory. pointing dbvica A terminal input device that allows you to make a selection from a menu or to draw graphics. See mouse, puck, stylus, and tablet. power-up sequence (power up) A series of ordered events that occur when you supply power by turning on the system. printer A peripheral device that provides paper copies of information stored on the system. program The sequence of instructions the system needs to perform a task. See software. prompt Words or characters that the system displays to indicate that it is waiting for you to type a command. . puck A flat, rectangular, 4-pushbutton pointing device included with the tablet, which moves the cursor on the monitor screen, draws graphics, and makes selections from the menu. See also tablet. RAM Abbreviation for Random-Access Memory. See Random-Access Memory (RAM). Random-Access Memory (RAM) Memory that can be both read and written into during normal operations. The type of memory the system uses to store the instructions of programs currently being run. raster A linear measurement unit for graphics characters. Read-Only Memory (ROM) A memory whose contents cannot be modified. The system can use the data contained in a ROM but cannot change it. Glossary-9 reboot To restart the system. Pressing the Restart pushbutton on the control panel reboots the VAXstation II/GPX system, if the Halt Enable/Disable switch on the back of the VAXstation II/GPX cabinet is in the up (enable) position. ROM Abbreviation for Read-Only Memory. See Read-Only Memory (ROM). run 1. A single continuous execution of a program. 2. To execute a program. software Programs executed by the system to perform a chosen or required function. Compare to hardware. storage medium Any device capable of recording information, for example, a diskette. store To enter data into a storage device, such as a disk, or into memory. stylus A stencil-shaped pointing device included with the tablet, which moves the cursor on the monitor screen, draws graphics, and makes selections from the menu. See also tablet. synchronous line controller A device that provides high-speed synchronous communication for distributed networks. Three varieties of the DMV11 are optional synchronous line controllers for the VAXstation I1/GPX. system A combination of system hardware, software, and peripheral devices that performs specific processing operations. system image The image that is read into memory from disk when the system is started up (booted). Glossary-10 system management tasks Tasks performed by the operating system and used to control the operation of the system. tablet An absolute-positioning input device comprised of a flat-surfaced digitizing tablet, a puck, and a stylus. The tablet is a drawing surface used with the puck or stylus as a pointing device to move the cursor on the monitor screen, and to draw graphics and make selections from the menu. The tablet may be used with the VAXstation II/GPX. tape drive A device that contains mechanical components and holds, tns, reads, and writes on magnetic tape. The VAXstation II/GPX uses the TK50 tape drive. Tektronix® 4014 A storage-tube display terminal sold by Tektronix, Inc. terminal An Input/Output device that allows you to communicate with the system. Terminals are divided into two categories: video and hard-copy. 32-bit length The length of the internal data path of the CPU. This length provides more concentrated data, allows more data types, and enables more data to be transferred at one time than a 16-bit internal data path. ULTRIX-32m ULTRIX-32m is an interactive, time-sharing operating system derived from UNIX® and enhanced by DIGITAL to work with MicroVAX hardware and software. ULTRIX-32w - The window management software for a MicroVAX-based system. The system must run ULTRIX-32m as the operating system. Workstation software allows you to control and view several programs on one screen. You specify the window with which to interact by using a pointing device. vCB02 A video subsystem that provides 1024 x 864 pixel resolution on a 47.5centimeter (19-inch) color monitor. The 4-plane subsystem simultaneously displays 16 colors, while the 8-plane subsystem simultaneously displays 256 colors. Glossary-11 video terminal A terminal that displays information on the screen of a cathode ray tube (CRT). Compare to hard-copy terminal. VLSI Very Large Scale Integration of integrated circuit chips. A large number of chips can fit on a printed circuit module; therefore fewer modules are needed, and the system can be smaller. VT100 terminal An American National Standards Institute (ANSI)-compatible terminal offered | by DIGITAL. Winchester disk A hard disk permanently sealed in a drive unit to prevent contaminants from affecting the read /write head. The sealed Head/Disk Assembly (HDA) helps to increase drive reliability and ensure data integrity. window | An area on your monitor screen in which you can start, run, and view a separate process. Windowing is supported by both MicroVMS and ULTRIX workstation software. word | | The largest number of bits (32) that the VAXstation II/GPX can handle in an operation. The VAXstation II/GPX can also handle longwords (that is, two words or 64 bits). write-protect To protect a disk, diskette, or other storage medium from the addition, revision, or deletion of information. write-protect notch The small notch on the side of an RX50 diskette that you can cover with an adhesive-backed foil label or tab to prevent loss of data by accidental overwriting. write-protect switch The switch that you slide down on a TK50 tape cartridge to prevent loss of data by accidental overwriting. Glossary-12 Index A DEQNA (cont’d.) Accessories kit components, 1-2 Asynchronous multiplexers description, 4-23, 4-24 installation, 4-23, 4-24 installation, 4-18 DESTA determining need for, 4-19 See DIGITAL ThinWire Ethernet Station Adapter, 4-21 DF112 modem description, 4-22 option, 4-22 Barrel connector DF124 modem description of, 4-20 description, 4-22 determining need for, 4-19 option, 4-22 BNE3x cable DF224 modem lengths, 4-19 description, 4-22 types, 4-18 option, 4-22 C DHV11 description, 4-24 Color monitor specifications, A-2 Communication modules description, 4-18 Connector determining need for, 4-19 Connectors list of, 4-20 Consolidation carton components, 1-2 Controller storage devices, 4-16 installation, 4-24 Diagnostics configuration and devices display, 5-18 exiting diagnostics, 5-18 field service menu, 5-18 initial display, 3-10 initial testing, 2-25 introductory display, 2-30 maintenance system, 5-17 maintenance system main menu, 5-17 mode switch, 2-32 power-up messages, 5-1 D RX50 diskette insertion, 2-28 DELNI description, 4-18 installation, 2-20 DEQNA description, 4-18 setting date and time, 2-30 system utilities menu, 5-18 testing with the RX50 diskette, 2-27 testing with the TK50, 2-25 Index—1 Diagnostics (cont’d.) | testing with the TK50, 2-25 test screen, 2-33 TK50 tape, 2-25 TK50 tape insertion, 2-27 DIGITAL ThinWire Ethernet Multiport Repeater, 4-20 F Fixed disk drive, RD53 specifications, A-7 Fixed disk drive, RD54 specifications, A-8 Fonts LA210, 4-6 DIGITAL ThinWire Ethernet Station Adapter, 4-21 features of, 4-21 ports of, 4-21 DIGITAL ThinWire Ethernet Station Adapter, definition, 4-21 Disk drive, fixed description, 3-13 location, 3-13 Diskette back-up, 3-24 description, 3-19 drive, 3-20 handling, 3-23 insertion, 3-22 labeled, 3-21 overwrite protection, 3-23 storage, 3-23 Diskette drive, RX50 Specifications, A-8 DMV11 description, 4-24 LCGO1, 4-9 LNO03, 4-2 Front control panel controls and indicators, 3-1 DC OK indicator, 3-5 fixed disk pushbuttons, 3-8 halt pushbutton, 3-6 power switch, 3-4 Restart/Run pushbutton, 3-5 Fuse replacing, 5-10 H H4000 installation, 4-18 Hardware support kit components, 1-2 Input devices mouse, 4-14 installation, 4-26 tablet, 4-13 Documentation hardware, 1-2, B-1 MicroVMS, B-4 ULTRIX, B-2 DPV11 description, 4-26 installation, 4-26 DZQ11 description, 4-23 installation, 4-23 E K Keyboard cable assembly connection, 2-7 installation, 2-7 KMV11 description, 4-27 installation, 4-27 L LA210 Environment system, 1-6 Index—2 description, 4-6 installation, 4-6, 4-12 LA210 (cont’d.) Memory module description, 4-14 picture of, 4-6 installation, 4-14 LAS50 types, 4-14 description, 4-8 installation, 4-9, 4-12 MicroVAX Diagnostic Monitor picture of, 4-9 main menu, 5-17 Modems list, 4-22 installation, 4-12 LA75 printer Monitor description, 4-7 option, 4-7 site-preparation, 1-4 Monitor, color cable assembly connection, 2-5 Labels placement of, 2-10 front and side controls, 3-11 fuse, 5-10 carrier, 5-11 location, 5-11 keyboard connection, 2-7 placement, 2-3 LCGO01 description, 4-9 installation, 4-10 LCPO1 installation, 4-12 power cord, 2-14, 2-17 LNO03 description, 4-2 power switch, 2-2 installation, 4-3, 4-12 power up, 2-24 picture of, 4-3 LNO03 PLUS installation, 4-12 LNO03 PLUS printer description, 4-3 rear controls and connectors, 3-12 specifications, 1-5, A-2 system unit connection, 2-13 troubleshooting procedures, 5-8 Mouse, 4-14 option, 4-3 cover plate, 5-13 LPS40 printer installation, 2-8 description, 4-4 option, 4-4 LVP16 description, 4-10 installation, 4-10, 4-12 M M7168 description, 4-15 installation, 4-15 M7169 maintenance, 5-13 schedule, 5-13 specifications, A-4 use of, xii MS630 description, 4-14 installation, 4-14 O Option DMYV11 synchronous line controller, 4-24 description, 4-15 Maintenance System options, 5-17 MDM, 5-17 Options DEQNA communications module, 4-18 Index-3 Options (cont’d.) Pointing device DHV11 asynchronous multiplexer, 4-24 installation, 2-8 Power requirements DPV11 synchronous line controller, 4-26 system, 1-5 Power up DZQ11 asynchronous multiplexer, messages, 5-1 4-23 KMV11 programmable controller, troubleshooting procedures, 5-3 Printers 4-27 connection to VAXstation I1/GPX, LA210, 4-6 4-11 LA50, 4-8 LA210, 4-6 LA75 printer, 4-7 LA50, 4-8 LCGO1, 4-9 list of, 4-1 LA75, 4-7 LNO03, 4-2 LNO3, 4-2 LNO3 PLUS printer, 4-3 LNO3 PLUS, 4-3 LVP16, 4-10 system unit connection, 4-12 LCGO1, 4-9 maintenance system main menu, 5-17 types, 4-2 PrintServer 40 (LPS40) memory modules, 4-14 description, 4-4 modems, 4-22 option, 4-4 mouse, 4-14 MS630, 4-14 4-plane module, 4-15 8-planes, 4-15 RD53 fixed disk drive description, 4-16 printers, 4-2 PrintServer 40 (LPS40) printer, 4-4 RD53 fixed disk drive, 4-16 specifications, A-7 RD54 fixed disk drive description, 4-16 RD54 fixed disk drive, 4-16 RX50 Dual Diskette Drive, 4-17 tablet, 4-13 TK50 Tape Drive, 4-17 specifications, A-8 Read and Write Errors troubleshooting procedures, 5-6 RQDX3, 4-16 RQDX3 controller, 4-16 P RX50, 4-16 4-plane Module description, 4-15 installation, 4-15 8-Planes description, 4-15 Plotter LVP16, 4-10 Pointing Device troubleshooting, 5-10 Index—4 | description, 4-17 installation, 4-17 specifications, A-8 s - Service procedures, 6-1 Shipment components listing, 1-1 eO Site-preparation Tape environment, 1-6 back-up, 3-24 description, 3-13 drive, 4-17, 5-7 power requirements, 1-5 space planning, 1-3 Software carton drive specifications, A-9 components, 1-2 handling, 3-19 Storage device option package, 4-16 insertion, 3-14 Synchronous line controlleres overwrite protection, 3-18 description, 4-26 storage, 3-19 Synchronous line controllers description, 4-24 TK50, A-9 T-connector installation, 4-26 Synchronous lines controllers installation, 4-26 description of, 4-20 determining need for, 4-19 Terminator System description of, 4-20 determining need for, 4-20 connecting the transceiver cable, 2-19 System halts ThinWire Ethernet connectors, 4-20 troubleshooting, 5-6 System unit terminator, 4-20 TK50, 4-16 adjusting baud rate, 2-12 connecting video cable, 2-13 troubleshooting, 5-7 Transceiver control panel, 2-10, 3-1 definition, 4-21 cover opening, 2-11 Transceiver cable, 4-18, 4-19 CPU distribution panel, 2-12 Troubleshooting diskette drive, 3-20 basic, 5-2 installation, 2-10 color monitor, 5-8 diskette drive, 5-5 labels, 2-10 physical specifications, 1-4 maintenance system, 5-17 power cord, 2-14, 2-18 power up, 5-1, 5-3 power on/off, 2-16 procedure, 5-1 power requirements, A-1 read and write errors, 5-6 setting controls, 2-12 system halts, 5-6 site-preparation, 1-3 system unit, 5-3 troubleshooting procedures, 5-3 voltage setting, 2-15 T TK50 tape drive, 5-7 Two-user system, 4-15 Vv Tablet VAXstation II/GPX description, 4-13 carton components, 1-2 installation, 2-8, 4-13 described, xi specifications, 4-13 specifications, A-5 use of, xii environmental requirements, 1-6, A-2 network, 2-19 Index—5 VAXstation II/GPX (cont’d.) options, xi, 4-1 power requirements, A-1 printer connection, 4-11 service, 6-1 shipment components, 1-2 site-preparation, 1-3 software installation, 2-35 testing, 2-24 troubleshooting, 5-1 turning off, 3-10 turning on, 3-8 VCB02 video subsystem, 4-15 Voltage system unit setting, 2-15 W Windows described, xii Index—6 HOW TO ORDER ADDITIONAL DOCUMENTATION From Call Alaska, Hawaii, 603-884-6660 or New Hampshire Rest of U.S.A. and Puerto Rico* Write Digital Equipment Corporation | P.O. Box CS2008 800-258-1710 Nashua, NH 03061 * Prepaid orders from Puerto Rico must be placed with DIGITAL'’s local subsidiary (809-754-7575) Canada 800-267-6219 (for software documentation) 613-592-5111 (for hardware Digital Equipment of Canada Ltd. 100 Herzberg Road Kanata, Ontario, Canada K2K 2A6 Attn: Direct Order desk documentation) Internal orders (for software documentation) Internal orders (for hardware documentation) o Software Distribution Center (SDC) Digital Equipment Corporation Westminster, MA 01473 617-234-4323 Publishing & Circulation Serv. (P&CS) NRO03-1/W3 Digital Equipment Corporation Northboro, MA 01532 A I R VAXstation II/GPX Owner’s Manual, BA 123 Enclosure EK-105AA-0OW-001 READ E E S COMM R’S Note: This form is for document comm ents ENTS form at the company’s discretion. DIGITAL will use comments submitted ononly. this Did you find this manual understandable, usable, and well organized? Please make suggestions for improvement. | Did you find errors in this manual? number, If so, specify the error and the page Please indicate the type of user/reade NelhS dministrative Support omputer Operator ducator/Trainer R DO0000oo0ogog r that you most nearly represent: rogrammer/Analyst Sales Scientist/Engineer Software Support System Manager Other (please specify) Name Date Organization Street City , State Zip Code or Country —— NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS PERMIT NO.33 MAYNARD MASS. POSTAGE WILL BE PAID BY ADDRESSEE DIGITAL EQUIPMENT CORPORATION CORPORATE USER PUBLICATIONS MLO5-5/E45 146 MAIN STREET MAYNARD, MA 01754-2571 T T T } Along Dotted Line ———— — — — r et — | o— Do Not Tear — Fold Here ——-,-s—s;—s—-;s—-sa—fl o
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies