Digital PDFs
Documents
Guest
Register
Log In
EK-DEFEB-IN-C01
May 1993
105 pages
Original
1.2MB
view
download
Document:
DECbridge 500/600 Series Installation and Upgrade
Order Number:
EK-DEFEB-IN
Revision:
C01
Pages:
105
Original Filename:
OCR Text
DECbridge 500/600 Series Installation and Upgrade Order Number: EK–DEFEB–IN. C01 NOTICE – Class A Laser Device: The lasers in this equipment are Class 1 devices, compliant with CDRH Rules 21, CFR Subchapter J, Part 1040.10, at date of manufacture. Class 1 laser devices are not considered to be hazardous. NOTICE – Class A Computing Device: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such radio frequency interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference; in which case, measures taken to correct the interference are at the user’s expense. CAUTION This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused in radios and TV receivers, etc. Read the instructions for correct handling. DECbridge 500/600 Series Installation and Upgrade March 1993 Supersession/Update Information: Order Number: EK-DEFEB-IN. C01 This is a revised manual. EK–DEFEB-IN. C01 March 1993 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. Copyright 1993 by Digital Equipment Corporation All Rights Reserved. Printed in U.S.A. The following are trademarks of Digital Equipment Corporation: DEC DECbridge DECconcentrator DECconnect DECdirect DECelms DECmcc DECnet DELNI DEMPR DESTA OpenVMS Scholar ThinWire VAX VMS VT ULTRIX MS-DOS is a registered trademark of Microsoft Corporation. Novell is a registered trademark of Novell, Inc. NetWare is a registered trademark of Novell, Inc. OS/2 is a registered trademark of International Business Machines Corporation. UNIX is a registered trademark of UNIX Systems Laboratories, Incorporated. Windows NT is a trademark of Microsoft Corporation. This manual was produced by Telecommunications and Networks Publications. Contents Safety Preface 1 Installing the Bridge 1.1 1.1.1 1.1.2 1.1.3 1.2 1.2.1 1.2.2 1.3 1.4 1.5 1.6 1.6.1 1.6.2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DECbridge 500/600 Series Features . . . . . . . . . . . . . . . . . . . DECbridge 500 Series Features . . . . . . . . . . . . . . . . . . . . . . . DECbridge 600 Series Features . . . . . . . . . . . . . . . . . . . . . . . Site Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Site Verification Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unpacking and Inspecting the Shipping Package . . . . . . . . . . . Setting Configuration Switches . . . . . . . . . . . . . . . . . . . . . . . . . Automatic Voltage Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Locations for Installing the DECbridge 500/600 Series Unit . . Installing the DECbridge 500/600 Series Unit on a Tabletop or Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the DECbridge 500/600 Series Unit in a Rackmount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1 1–2 1–3 1–3 1–3 1–4 1–5 1–5 1–7 1–7 1–7 1–7 1–8 iii 2 Installing a New Module to Upgrade the Bridge 2.1 2.2 2.3 2.4 2.4.1 2.4.2 2.5 2.6 2.7 2.7.1 2.8 3 2–1 2–2 2–2 2–4 2–5 2–5 2–5 2–6 2–6 2–8 2–9 Connecting Communications Cables and Verifying Bridge Operation 3.1 3.2 3.2.1 3.2.2 3.3 3.4 3.4.1 3.4.1.1 3.4.2 3.5 3.5.1 3.5.2 3.6 3.6.1 3.7 3.8 iv Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DECbridge 500/600 Series Technical Information . . . . . . . . . . Unpacking and Inspecting Upgrade Kits . . . . . . . . . . . . . . . . . . Site Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Site Verification Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparing the Bridge for Upgrade . . . . . . . . . . . . . . . . . . . . . . . Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removing a DECbridge Module . . . . . . . . . . . . . . . . . . . . . . . . Installing a DECbridge 500/600 Series Module . . . . . . . . . . Updating Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the ThinWire Cable . . . . . . . . . . . . . . . . . . . . . . . . . Connecting to the Middle of a ThinWire Segment . . . . . . . . Connecting to the End of a ThinWire Segment . . . . . . . . . . . Connecting the AUI Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the FDDI Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting an FDDI Cable with a Multimode Connector . . Installing the Optical Bypass Switch . . . . . . . . . . . . . . . . . Connecting an FDDI Cable with a Single-mode Connector . Connecting the OBM Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting the OBM Cable Directly to a Terminal . . . . . . . Connecting the OBM Cable Through a Modem to a Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verifying Bridge Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powering Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Checking the Logical Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Final Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1 3–2 3–3 3–3 3–4 3–7 3–7 3–8 3–9 3–11 3–12 3–12 3–13 3–13 3–16 3–16 4 Using Local Console Management 4.1 4.2 4.2.1 4.3 4.4 4.5 5 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessing LCM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Attributes Displayed When Using LCM . . . . . . . . . . . . . . . . Messages Displayed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting the Attribute Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching from LCM to SLIP MODE . . . . . . . . . . . . . . . . . . . . Solving Problems 5.1 Basic Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 Determining Symptoms and Following Corrective Actions . 5.1.2 Port Loopback Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2.1 Installing the Loopback Connectors . . . . . . . . . . . . . . . . . 5.1.2.2 Running the Loopback Test and Observing the Results . . 5.1.2.3 Returning to Normal Operation . . . . . . . . . . . . . . . . . . . . . A 5–1 5–2 5–8 5–8 5–12 5–12 DECbridge 500/600 Series Models A.1 B 4–1 4–2 4–3 4–5 4–5 4–5 DECbridge Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A–4 Switches and Indicators B.1 B.2 B.3 B.4 B.5 B.6 B.7 Configuration Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bridge LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Bypass Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FDDI Connector Keying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FDDI Connection Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B–1 B–5 B–7 B–7 B–8 B–9 B–10 v C Specifications C.1 C.1.1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Hardware Upgrade Options E Related Documents C–1 C–3 Index Examples Figures 1–1 1–2 1–3 1–4 1–5 2–1 2–2 2–3 2–4 2–5 3–1 3–2 3–3 3–4 3–5 3–6 vi A DECbridge 500/600 Series Unit (I/O Panel) . . . . . . . . . . . . . Shipping Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing U-Nuts on Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Attaching Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . Installing a Bridge in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . DEFEB-UP Upgrade Kit Contents . . . . . . . . . . . . . . . . . . . . . . . DEFEB-UG Upgrade Kit Contents . . . . . . . . . . . . . . . . . . . . . . DEFEB-UR Upgrade Kit Contents . . . . . . . . . . . . . . . . . . . . . . Module Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . Locations for Applying Upgrade Labels . . . . . . . . . . . . . . . . . . ThinWire, AUI, FDDI, and OBM Connectors . . . . . . . . . . . . . . ThinWire Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . AUI Connector Slide Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . FDDI Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recommended Connections for the OBM Cable . . . . . . . . . . . . Connecting the OBM Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 1–6 1–8 1–9 1–10 2–2 2–3 2–4 2–8 2–10 3–2 3–4 3–6 3–10 3–11 3–12 3–7 4–1 5–1 5–2 A–1 B–1 B–2 B–3 B–4 DECbridge Unit Indicator LEDs After Power Up . . . . . . . . . . . Access Methods for OBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the FDDI Loopback Connectors . . . . . . . . . . . . . . . . Installing the NI Loopback Connectors . . . . . . . . . . . . . . . . . . . DECbridge 500/600 Series Modules . . . . . . . . . . . . . . . . . . . . . Configuration Switches and LED Indicators . . . . . . . . . . . . . . . Optical Bypass Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . DECbridge 500/600 Series MIC Receptacle Keying . . . . . . . . . FDDI Connection Rules Matrix . . . . . . . . . . . . . . . . . . . . . . . . . 3–15 4–2 5–10 5–11 A–5 B–2 B–8 B–9 B–10 LED Indicator Symptoms and Corrective Actions . . . . . . . . . . DECbridge 500/600 Series Models . . . . . . . . . . . . . . . . . . . . . . Power Cord Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . Acoustic Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5–2 A–2 A–6 B–4 B–5 C–2 C–2 C–2 C–3 C–3 Tables 5–1 A–1 A–2 B–1 B–2 C–1 C–2 C–3 C–4 C–5 vii Safety ! Any warning or caution that appears in this manual is defined as follows: Warning Contains information to prevent personal injury. Caution Contains information to prevent damage to equipment. Vorsicht Enthält Informationen, die beachtet werden müssen, um den Benutzer vor Schaden zu bewahren. Achtung Enthält Informationen, die beachtet werden müssen, um die Geräte vor Schaden zu bewahren. Danger Signale les informations destinées à prévenir les accidents corporels. Attention Signale les informations destinées à prévenir la détérioration du matériel. Aviso Contiene información para evitar daños personales. Precaucion Contiene información para evitar daños al equipo. ix The warnings and cautions that must be observed for the hardware described in this manual are listed below in English, German, French, and Spanish. The pages on which these safety messages appear are also listed. WARNING ! To prevent bodily injury or equipment damage, DO NOT connect the bridge power cord until instructed. [Page 1-7] VORSICHT Schließen Sie das Netzkabel erst an, wenn Sie dazu aufgefordert werden. DANGER Afin d’éviter tout risque d’accident corporel, NE RACCORDEZ PAS le cordon d’alimentation du DECbridge avant d’en avoir reçu l’instruction. AVISO Para evitar daños personales, NO conecte el cable de alimentación del puente hasta que se le indique. WARNING ! When performing any removal or replacement procedures, always remove the ac power cord from the ac power source. [Page 2-5] VORSICHT Ziehen Sie immer zuerst das Netzkabel aus der Steckdose, wenn Sie Teile austauschen oder entfernen müssen. DANGER Au moment de retirer ou de remplacer des composants internes, débranchez toujours le cordon d’alimentation de la prise. AVISO Siempre que se sustituya o se quite algo, saque el cable de alimentación de corriente alterna de la toma. WARNING ! Some fiber optic equipment can emit laser light that can injure your eyes. Never look into an optical fiber, cable connector, or port connector. [Pages 2-6, 3-7] VORSICHT Schauen Sie niemals direkt in ein Glasfaserkabel oder einen Glasfaseranschluß. Die Laserstrahlen in faseroptischen Geräten können Augenverletzungen verursachen. DANGER Certains équipements utilisant les fibres optiques peuvent émettre des rayonnement laser dangereux pour les yeux. Ne vous avisez jamais de regarder par l’extrémité d’une fibre optique ou dans l’ouverture d’un connecteur. Considérez toujours que le câble est relié à une source lumineuse. x Algunos equipos de fibra óptica emiten radiaciones láser que pueden dañar la vista. Nunca mire directamente a un conector o puerta de conector de fibra óptica. AVISO CAUTION ! Modules in the bridge can be damaged by electrostatic discharges (ESD). When working inside the unit, always use a grounded wrist strap (ESD strap) and a grounded work surface. A wrist strap, ground wire, and table pad are included in the field service kit (P/N 29-11762-00). [Page 2-6] ACHTUNG Die Module können durch elektrostatische Entladungen beschädigt werden. Benutzen Sie immer eine antistatische Gelenkmanschette und eine geerdete Arbeitsunterlage, wenn Sie am offenen Gerät arbeiten. Der Antistatikkit für das Wartungspersonal enthält eine antistatische Gelenkmanschette, Schutzleiterdraht und eine Antistatikmatte. Ein Antistatikkit ist bei DECdirekt unter der Bestellnummer 29-11762-00 erhältlich. ATTENTION Les charges excessives d’électricité statique peuvent endommager les modules et les composants électroniques. Lors de la manipulation des modules et des composants internes, utilisez toujours le bracelet de masse et le plan de travail antistatique livrés avec le kit d’entretien (Réf. 29-11762-00). PRECAUCION Los módulos del puente pueden ser dañados por descargas electroestáticas (ESD). Cuando se trabaje dentro de la unidad, use una muñequera antiestática y una superficie de trabajo conectadas ambas a tierra. En el juego de reparación (P/N29-11762-00) se incluye una muñequera antiestática, un cable de tierra y una tabla. CAUTION ACHTUNG ! DECbridge 500/600 series modules have components on both sides of a module. Remove or insert a module straight (not at an angle) to prevent damage. [Page 2-6] Auf Modulen der Serie DECbridge 500/600 befinden sich auf beiden Seiten Bauteile. Entfernen und installieren Sie Module absolut waagrecht, damit sie nicht beschädigt werden. xi ATTENTION Les cartes du DECbridge 500/600 comportent des composants sur les deux faces. Afin d’éviter tout risque de détérioration, veillez à respecter l’alignement lors des opérations de retrait ou de remplacement d’une carte. PRECAUCION Los módulos de las series DECbridge 500/600 tienen componentes a ambos lados. Inserte o retire los módulos derechos, no en ángulo, para evitar deterioros. CAUTION ! Trying to force a module into the wrong slot may damage the keys. [Page 2-8] ACHTUNG Bringen Sie ein Modul nicht mit Gewalt in einem anderen als dem vorgesehenen Steckschlitz an. Andernfalls können die Steckzungen beschädigt werden. ATTENTION L’insertion forcée d’une carte dans la mauvaise fente risque d’endommager les guides. PRECAUCION Si se fuerza un módulo para que entre en una ranura inadecuada se pueden dañar las llaves. CAUTION ! Ensure that the bend radius of any fiber optic cable is 2.5 centimeters (1 inch) or greater. [Page 3-7] ACHTUNG Der Biegungsradius von faseroptischen Kabeln muß mindestens 2.5 cm betragen. ATTENTION Assurez-vous que le rayon de courbure de tout câble à fibres optiques est égal ou supérieur à 2.5 centimètres. PRECAUCION Compruebe que el radio de curvatura de cualquier cable de fibra óptica es 2.5 centímetros (1 pulgada) o mayor. CAUTION ACHTUNG xii ! Do not touch fiber ends; doing so may cause optical power loss. [Page 3-9] Berühren Sie keine freiliegenden Faserenden. Andernfalls können optische Übertragungsverluste auftreten. ATTENTION Ne touchez pas aux extrémités des fibres, car cela peut causer la perte de puissance du signal optique. PRECAUCION Evite tocar los extremos de la fibra, porque podría originar pérdida de capacidad óptica. ! Be sure to connect the power cord to a grounded wall outlet. [Page 3-13] WARNING VORSICHT Schließen Sie das Netzkabel nur an eine geerdete Steckdose an. Assurez-vous que la prise à laquelle est raccordé le DECbridge est munie d’une mise à la terre. DANGER Asegúrese de conectar el cable de alimentación a una toma de pared (tierra). AVISO ! WARNING To prevent personal injury or equipment damage, do not insert telecommunications cabling into the optical bypass relay connector. (Page 5-8, B-8) VORSICHT Um Personen oder Geräteschäden zu vermeiden, dürfen Sie das Telefonkabel AUF KEINEN FALL am Anschluß des optischen Bypass-Relais anschließen. DANGER Pour éviter tout risque d’accident corporel ou de dommage matériel, NE BRANCHEZ PAS de câble de télécommunication sur le connecteur de relais sélectif optique (optical bypass relay connector). AVISO Para evitar daños personales o al equipo, NO se debe introducir cableado de telecomunicaciones en el conector óptico de relés de derivación. CAUTION ACHTUNG ! The air inside a rack can be hotter than the ambient room temperature. Make sure the air entering the bridge does not exceed the maximum inlet temperature of 50° C (122° F). [Page C-1] Die Lufttemperatur im Gehäuse kann beträchtlich höher sein als die umgebende Raumtemperatur. Achten Sie darauf, daß die maximale Einlaßtemperatur nicht höher als 50 Grad Celsius ist. xiii ATTENTION La température de l’air circulant à l’intérieur d’une baie fermée peut être supérieure à celle de la pièce. Assurezvous que la température à la prise d’air du DECbridge n’excède pas 50° C. PRECAUCION El aire que se encuentra dentro de la carcasa puede estar más caliente que la temperatura ambiente de la habitación. Asegúrese de que el aire que penetra en el puente no supera una temperatura máxima de 50 grados centígrados (122° F). xiv Preface This manual explains how to install or upgrade a DECbridge 500/600 series bridge and how to verify its operation once installed or upgraded. If you are installing the bridge, follow the instructions in Chapter 1, then proceed to Chapter 3 to install communications cabling and verify unit operation. If you are upgrading the bridge, follow the instructions in Chapter 2, then proceed to Chapter 3 to install communications cabling and verify unit operation. Intended Audience This manual is intended for the following audience: • Hardware installer • System/network manager Document Structure This manual contains five chapters and five appendixes: Chapter 1 Provides illustrated procedures for installing a DECbridge unit. Chapter 2 Provides illustrated procedures for upgrading a DECbridge unit. Chapter 3 Provides communications cabling instructions and information to verify proper operation of the bridge. xv Chapter 4 Describes the Local Console Manager (LCM). Also describes how to use LCM to access out-of-band management (OBM). Chapter 5 Provides general solutions and help in isolating problems that may occur during installation. Appendix A Lists the models in the DECbridge 500/600 Series bridges. Also includes an overview of the bridge modules. Appendix B Provides information on bridge switches and indicators. Appendix C Provides specifications on the bridge. Appendix D Provides upgrade options information. Appendix E Lists related documentation. The postage-paid Reader’s Comments form on the last page of this document requests your critical evaluation to assist us in preparing future documentation. xvi 1 Installing the Bridge This chapter provides instructions for installing the DECbridge 500/600 Series bridges. After installing a bridge, follow the procedures in Chapter 3 for connecting communications cables and verifying the unit’s operation. If you are performing an upgrade to an installed bridge, refer to Chapter 2. 1.1 Introduction The DECbridge 500/600 Series bridges, also referred to in this manual as the bridges or units, are FDDI-to-IEEE 802.3/Ethernet-transparent translating bridges. They provide the interconnection between a high-speed (100-Mb/s) Fiber Distributed Data Interface (FDDI) network backbone and up to three midspeed (10-Mb/s) IEEE 802.3/Ethernet LAN network segments. The Single Attachment Station (SAS) version of DECbridge units has one FDDI connector on the Fiber Interface (FI) module. The Dual Attachment Station (DAS) version of DECbridge units has two FDDI connectors on the FI module. Figure 1–1 shows components on the bridge. 1–1 Figure 1–1: A DECbridge 500/600 Series Unit (I/O Panel) Model number OBM connector Circuit breaker AC power connector Serial number Address label AUI connector (Port 2) AP NI FI Module I.D. QM ThinWire connector (Port 2) Configuration switches FDDI connector (Port 1) LKG-7321-92I 1.1.1 DECbridge 500/600 Series Features All DECbridge 500/600 Series models share the following features: • An AP3 module with out-of-band management (OBM) support (all models except the DECbridge 500 model) NOTE You need Version 1.3 (or higher) bridge firmware if your unit has an AP3 module. 1–2 • A Local Console Manager (LCM) • Rate limiting • Station Management (SMT) support • Bridge Management Information Base (Bridge MIB) • FDDI MIB DECbridge 500/600 Series Installation and Upgrade 1.1.2 DECbridge 500 Series Features The DECbridge 500 Series models have the following features: • One-port NI module that provides connection for either a ThinWire or AUI (also known as thickwire) Ethernet network connection • One-port FI module that has one or two connectors, depending on the type of FDDI interface connection—either a SAS or DAS connection 1.1.3 DECbridge 600 Series Features The DECbridge 600 Series models have the following features: • Three-port NI module that provides for up to three AUI Ethernet network connections • One-port FI module that has zero, one, or two FDDI connectors, depending on the type of interface connection — either a SAS connection or DAS connection (a DECbridge 600 unit has no FDDI interface) 1.2 Site Verification Before installing a DECbridge 500/600 Series unit, ensure that all cables for the site configuration are installed and labeled properly. Refer to the DECconnect System Fiber Optic Installation manual for information regarding DECconnect System fiber optic installations (refer also to the Fiber Distributed Data Interface Network Configuration Guidelines manual for FDDI network configuration rules and cableplant specifications). For information regarding satellite equipment room (SER) installations, consult the DECconnect System Satellite Equipment Room Installation Guide. The DECbridge 500/600 Series unit can be placed in open office areas and computer rooms. The environmental requirements (in Appendix C) can assist you in determining the proper location. You can install the bridge on a tabletop, desktop, or in a rack. Installing the Bridge 1–3 A DECbridge 500/600 Series unit is connected to an FDDI ring through a concentrator (SAS bridge), such as the DECconcentrator 500, or is directly connected using a DAS bridge. The bridge connects to IEEE 802.3/Ethernet LANs through a transceiver or ThinWire cabling. For more information on FDDI network configurations and bridge connections, refer to the Fiber Distributed Data Interface Network Configuration Guidelines manual (refer to Appendix E for more documentation information). 1.2.1 Site Verification Checklist Use the following checklist to make sure a site is ready for installation of the DECbridge 500/600 Series unit: Ensure that a concentrator, such as the DECconcentrator 500, is installed if you are connecting your bridge to an FDDI ring through a concentrator. Ensure that the AUI or ThinWire cabling is available in the required length. Ensure that the AUI or ThinWire cabling is installed, tested, and tagged. Tagging is especially important when an NI(3) module is installed. Ensure that the FDDI fiber optic cabling is available in the required length. Ensure that the FDDI fiber optic cabling is installed, tested, and tagged. Ensure that the ac power outlet is grounded and working properly. The outlet location should be within 1.8 meters (6 feet) of the installation site for U.S. sites and 2.5 meters (8.2 feet) for international sites. Ensure that the voltage and amperage at the ac wall outlet are correct for installing the bridge. Verify that the temperature, altitude, and humidity for the site are with in the specified ranges (refer to Appendix C). If planning to use LCM, ensure that your video terminal passes self-test. 1–4 DECbridge 500/600 Series Installation and Upgrade Ensure that there is a minimum of 7.6 centimeters (3 inches) on the sides of the unit for ventilation and a minimum of 17.8 centimeters (7 inches) of vertical mounting space in a rackmount. Ensure that the extended LAN is properly configured in regards to IEEE 802.1d and Digital spanning tree loop detection modes (refer to the Bridge and Extended LAN Reference manual for more information). 1.2.2 Service Optional on-site and remote Digital services are available. Call your Digital Services representative for information regarding hardware and software services that are available to support your DECbridge 500/600 Series unit. 1.3 Unpacking and Inspecting the Shipping Package The DECbridge 500/600 Series unit is shipped in one box (see Figure 1–2 for contents). Remove the bridge from the box and place it on a flat surface until you are ready to install it. Check the shipment for damage and missing parts. In case of damage, contact your delivery agent and your Digital sales representative. If parts are missing, contact your Digital sales representative. NOTE Communications cables (ThinWire, AUI, and FDDI) for this product are ordered and shipped separately, and are not included in the DECbridge 500/600 Series unit shipping box. A power cord ships with U.S./Canada versions of the bridge (for example, DEFEB-AC). Power cord kits are available from Digital for bridges shipped to other countries (refer to Appendix A for a list of power cord kits). Once you have unpacked the bridge, follow the instructions for setting bridge switches (if applicable) and installing the unit included in this chapter. Installing the Bridge 1–5 Figure 1–2: Shipping Package Contents Power cord (U.S. only) P/N BN20A-2E Rack U-nuts P/N 90-07786-00 ThinWire T-Connector P/N 12-25869-01 (500 series only) Mounting bracket screws P/N 90-08404-02 T-connector terminators P/N 12-26318-01 (500 series only) Mounting brackets P/N 74-39897-01 AUI loopback P/N 12-22196-01 (1 or 3 provided depending on model) FDDI loopback P/N 12-32005-01 (0, 1, or 2 provided depending on model) Single-mode loopback P/N 12-34830-01 (0, 1 or 2 provided depending on model) Rack screws P/N 90-00063-39 License, software product description, release notes, Configuring the SNMP Agent manual P/N QC-018AA-GZ DECbridge 500/600 Series Installation and Upgrade manual (this manual) P/N EK-DEFEB-IN FDDI Network Configuration Guidelines manual P/N EK-DFDDI-CG (DECbridge 510 shown) LKG-7315-92I 1–6 DECbridge 500/600 Series Installation and Upgrade 1.4 Setting Configuration Switches A DECbridge 500/600 Series unit is shipped from the factory with the configuration switches preset in the OFF position (default settings). If you have a DECbridge 500 Series unit, set switch 8 to the proper setting for AUI or ThinWire interface (this switch does not apply for DECbridge 600 Series units). Otherwise, use the default settings for normal operation. To perform remote management on the bridge, set the write access switches on the bridge to ON. Refer to Appendix B for more information on switch settings. 1.5 Automatic Voltage Setting The DECbridge 500/600 Series units automatically adjust to a voltage range of 88 to 264 Vac. Therefore, the bridges have no voltage-select switch. 1.6 Locations for Installing the DECbridge 500/600 Series Unit You can install a DECbridge 500/600 Series unit on a tabletop, desktop, or in a standard 48-centimeter (19-inch) rack. The shipping contents include a set of mounting brackets and screws for use in a rackmount installation (refer to Section 1.6.2). Follow the instructions for the type of installation at your site. WARNING ! To prevent bodily injury or equipment damage, DO NOT connect the bridge power cord until instructed. NOTE A minimum of 7.6 centimeters (3 inches) of free air space is required on each side of the unit. 1.6.1 Installing the DECbridge 500/600 Series Unit on a Tabletop or Desktop To install a DECbridge 500/600 Series unit on a tabletop or desktop, remove it from the shipping box, remove any packaging, and place it on the surface where you will use it. After you install the bridge, proceed to Chapter 3 for instructions on installing communications cables and verifying bridge operation. Installing the Bridge 1–7 1.6.2 Installing the DECbridge 500/600 Series Unit in a Rackmount Rackmount installation of the bridge involves installing u-nuts on the rack rails, attaching the mounting brackets to the sides of the bridge, and installing the bridge in the rack. NOTE Two people are required to install the DECbridge 500/600 Series unit in a rack. When positioning the bridge in the rack, one person should hold the unit while the other installs the screws. Before installing the bridge in the rack, determine where the unit will be placed in the rack and perform the following steps: 1. Attach four u-nuts to the rails of the rack (see Figure 1–3). Hold a mounting bracket up to the rack rail where it will be positioned when installed. This helps identify the proper holes for placing the u-nuts. Figure 1–3: Installing U-Nuts on Rack Device U-nuts Device Front of cabinet LKG-3962-91I 1–8 DECbridge 500/600 Series Installation and Upgrade 2. Attach the mounting brackets (one on each side) to the bridge using the six flathead screws supplied in the shipping box (see Figure 1–4). Figure 1–4: Attaching Mounting Brackets LKG-4858-93I Installing the Bridge 1–9 3. Install the bridge in the rack with the I/O panel visible (see Figure 1–5). Secure the bridge to the rack rail with the four screws provided in the shipping box. Proceed to Chapter 3 to install communications cables and verify bridge operation. Figure 1–5: Installing a Bridge in a Rack LKG-4859-93I 1–10 DECbridge 500/600 Series Installation and Upgrade 2 Installing a New Module to Upgrade the Bridge This chapter provides instructions for upgrading your DECbridge 500/600 Series unit to another model in the DECbridge 500/600 Series. If you are performing a bridge installation, follow the installation procedures in Chapter 1. Upgrading your bridge to another model includes: 1. Replacing the current module(s) in the bridge with upgrade module(s) 2. Installing new model number labels 3. Connecting communications cables and verifying bridge operation by following the procedures in Chapter 3 2.1 Introduction Upgrading modules on the DECbridge 500/600 Series of bridges allows you to increase interface connections to accommodate growing networks without purchasing new units. For DECbridge 500 Series units, you can add two more AUI interface connections. For both DECbridge 500 and 600 Series units, you can add another FDDI connection that allows you to use dual homing on your bridge, connect your bridge directly to an FDDI ring (DAS connection), and connect to networks up to a distance of 40 kilometers (24.8 miles). Refer to Appendix D for more information on upgrade possibilities. 2–1 2.2 DECbridge 500/600 Series Technical Information The appendixes at the back of this manual contain all technical information pertaining to DECbridge units, such as model numbers, module descriptions, unit specifications, LED indicators, and configuration switches. 2.3 Unpacking and Inspecting Upgrade Kits Each DECbridge 500/600 Series upgrade kit (Digital offers three kits) is shipped in its own box. Figure 2–1, Figure 2–2, and Figure 2–3 illustrate the contents of the shipping boxes. Check the shipment for damaged or missing parts. If parts are damaged, contact your delivery agent and your Digital sales representative. If parts are missing, contact your Digital sales representative. Figure 2–1: DEFEB-UP Upgrade Kit Contents FI DAS multimode module P/N 54-19369-02 G 1 G A PHY 1 B PHY 2 G G G FI multimode loopback connector P/N 12-32005-01 DECbridge documentation kit P/N DEFEB-DK Includes the following: • DECbridge 500/600 Series Installation and Upgrade manual P/N EK-DEFEB-IN • Label sheet P/N 36-35439-01 510 518 520 524 526 528 600 610 618 620 624 626 628 DECbridge 600 LKG-7326-92I 2–2 DECbridge 500/600 Series Installation and Upgrade Figure 2–2: DEFEB-UG Upgrade Kit Contents AP3 module P/N 54-19375-02 R 2 Y G AUI G G NI(3) module P/N 54-19409-01 R 2 Y G G 3 Y G 4 Y G Two Ethernet (AUI) loopback connectors P/N 12-22196-01 License, software product description, release notes, Configuring the SNMP Agent manual P/N QC-018AA-GZ DECbridge documentation kit P/N DEFEB-DK Includes the following: • DECbridge 500/600 Series Installation and Upgrade manual P/N EK-DEFEB-IN • Label sheet P/N 36-35439-01 510 518 520 524 526 528 600 610 618 620 624 626 628 DECbridge 600 LKG-7328-92I Installing a New Module to Upgrade the Bridge 2–3 Figure 2–3: DEFEB-UR Upgrade Kit Contents AP 3module P/N 54-19375-03 R 2 Y G AUI G G License, software product description, release notes, Configuring the SNMP Agent manual P/N QC-018AA-GZ DECbridge documentation kit P/N DEFEB-DK Includes the following: • DECbridge 500/600 Series Installation and Upgrade manual P/N EK-DEFEB-IN • Label sheet P/N 36-35439-01 510 518 520 524 526 528 600 610 618 620 624 626 628 DECbridge 600 LKG-7318-92I 2.4 Site Verification Before upgrading the DECbridge 500/600 Series unit, ensure that all cables for the upgraded site configuration are installed and labeled properly. Refer to the DECconnect System Fiber Optic Installation manual for information regarding DECconnect System fiber optic installations. For information regarding SER installations, consult the DECconnect System Satellite Equipment Room Installation Guide. 2–4 DECbridge 500/600 Series Installation and Upgrade 2.4.1 Site Verification Checklist Use the following checklist to prepare the site for an upgrade to your DECbridge 500/600 Series unit: Ensure that a concentrator, such as the DECconcentrator 500 unit, is installed if you are connecting to an FDDI ring through a concentrator. Ensure that the AUI or ThinWire cabling is available in the required length. Ensure that the AUI or ThinWire cabling is installed, tested, and tagged. Ensure that the FDDI fiber optic cabling is available in the required length. Ensure that the FDDI fiber optic cabling is installed, tested, and tagged. 2.4.2 Service Digital offers optional on-site service agreements. Call your Digital sales representative for information about the hardware and software services that are available for your DECbridge 500/600 Series unit. 2.5 Preparing the Bridge for Upgrade You can access the bridge modules from the I/O panel. WARNING ! When performing any removal or replacement procedures, always remove the ac power cord from the ac power source. Before performing upgrade procedures on the bridge, perform the following steps: 1. Remove power to the bridge by unplugging the power cord from the ac outlet. Installing a New Module to Upgrade the Bridge 2–5 2. Disconnect the AUI or ThinWire interface cable from the NI module. A slide latch locks the AUI cable connector locks into place. To remove the AUI cable, push the slide latch to the right to unlock the connector. To remove the ThinWire cable, push in and rotate the connector a quarter-turn counterclockwise. WARNING ! Some fiber optic equipment can emit laser light that can injure your eyes. Never look into an optical fiber, cable connector, or port connector. 3. Remove the fiber optic cable from the FI module. If you have a protective cover, place it on the fiber optic connector to protect it against dust. 2.6 Tools Required You need a #2 Phillips-head screwdriver and an electrostatic discharge (ESD) strap to remove and replace modules. CAUTION ! Modules in the bridge can be damaged by electrostatic discharges (ESD). When replacing modules in the unit, always use a grounded wrist strap (ESD strap) and a grounded work surface. A wrist strap, ground wire, and table pad are included in the field service kit (P/N 29-11762-00). 2.7 Removing a DECbridge Module To remove a module, refer to Figure 2–4 and perform the following steps: CAUTION ! DECbridge 500/600 Series modules have components on both sides of a module. Remove or insert a module straight (not at an angle) to prevent damage. 1. Using network management software, record bridge parameter settings and the firmware version. 2–6 DECbridge 500/600 Series Installation and Upgrade 2. Before removing an AP module, record the existing switch settings on that module so that they can be used as reference to configure the new AP3 module. 3. Ensure the power is turned off and interface cables are disconnected (refer to Section 2.5). 4. Attach the ESD ground strap around your wrist and clip the other end of the strap to the ejector lever on a module you are not removing, such as the QM module. 5. Using a #2 Phillips-head screwdriver, loosen the quarter-turn fastener on each end of the module by pushing it in and turning it a quarter turn counterclockwise. The fastener pops out when unlocked. 6. Swing the two ejector levers on the module to the unlock (outward) position. 7. Carefully slide the module straight out of the card cage to remove it. Do not let the components on the bottom of the module scrape against the ejector levers of the module below. Installing a New Module to Upgrade the Bridge 2–7 Figure 2–4: Module Removal and Replacement Quarter-turn Quarter-turn fastener (2) AP module NI module Ejector lever (2) FI module QM module Locked Unlocked LKG-7323-92I 2.7.1 Installing a DECbridge 500/600 Series Module Follow this procedure for any of the modules. Verify that you have the correct replacement module by checking the name of that module on the left side of the module handle. (The revision level is shown on the right side of the handle.) The card cage slots are also labeled, as shown in Figure 2–4. Each module is keyed so that it can lock into place only if it is in the proper slot. CAUTION ! Trying to force a module into the wrong slot may damage the keys. 2–8 DECbridge 500/600 Series Installation and Upgrade NOTE Ensure that the switches on a replacement AP3 module are set to the proper positions for the new configuration. Refer to Appendix B for switch descriptions. NOTE Because the AP module contains the address ROM for the bridge, the physical addresses of the bridge change when you replace the AP module. An address label on the new AP3 module lists the new addresses. To install a module, refer to Figure 2–4 and perform the following steps: 1. Verify that the replacement module is correct (the name is on the left side of the module handle). 2. Verify that the module ejector levers are in the unlock position (swung outward). Hold the replacement module component side up and carefully slide it into the appropriate card cage slot until it makes contact with the backplane connector. Do not let the components on the bottom of the module scrape against the ejector levers of the module below it. 3. Firmly push the ejector levers inward until the module is fully seated into the connector. (Note that when all modules are properly inserted, all the ejector levers should be aligned.) 4. Using the Phillips-head screwdriver, tighten the two quarter-turn fasteners that attach the module to the card cage (by pushing in and turning the screwdriver clockwise). 2.8 Updating Labels Update the labels that appear on the outside of the bridge once you have completed the module upgrade. A peel-and-stick label sheet is provided in the shipping package. Replace two labels: 1. If an NI(3) module has been installed, peel the DECbridge front panel label from the label sheet (located on the bottom right side of the sheet) and place it directly over (covering) the DECbridge model number located on the front panel of the unit (see Figure 2–5). Line up the new DECbridge label with the top of the existing label and press firmly so that the label stays in place. Installing a New Module to Upgrade the Bridge 2–9 2. Peel the specific DECbridge model number from the label sheet and place it directly over (covering) the DECbridge model number located on the I/O panel (see Figure 2–5). Press firmly so that the label stays in place. 3. Once the two labels have been updated, use a pen or permanent marker to update the DEFEB part number (located on the I/O panel serial number label) to the model you are upgrading to. Cross out the last two digits of the part number and write the new numbers to the right of the crossed-out numbers. For example, if you have model DEFEB-AC (DECbridge 510) and are upgrading to model DEFEB-LA (DECbridge 620), cross out the letters AC and write in letters LA. Refer to Appendix A for a list of model numbers. The DECbridge 500/600 Series unit is now ready for cabling. Refer to Chapter 3 for cabling instructions. Figure 2–5: Locations for Applying Upgrade Labels Label sheet 510 518 520 524 526 528 600 610 618 620 624 626 628 DECbridge 600 Front panel label Specific model number DECbridge 600 AP NI FI QM I/O Panel Front panel LKG-7320-92I 2–10 DECbridge 500/600 Series Installation and Upgrade 3 Connecting Communications Cables and Verifying Bridge Operation This chapter provides instructions for connecting communications cables and verifying proper bridge operation. 3.1 Introduction To connect communications cables, follow the instructions in the following sections for the cables you are connecting: • Connecting the ThinWire Cable — Section 3.2 • Connecting the AUI Cable — Section 3.3 • Connecting the FDDI Cable — Section 3.4 • Connecting the OBM Cable — Section 3.5 NOTE Verify that the site is prepared for cable installation. Refer to the site verification checklist in Chapter 1 for more information on site requirements. 3–1 NOTE When connecting communications cables, verify that you are connecting the correct cable to the proper connector on the I/O panel by reading the label and noting the type of connector on the cable. If you have a DECbridge 600 Series unit, the NI module has three AUI connectors and no ThinWire connector (Port 2). If you have a DAS configuration, the FI module has two FDDI connectors (Port 1). Figure 3–1 shows connector locations on the I/O panel for all cables. Figure 3–1: ThinWire, AUI, FDDI, and OBM Connectors ThinWire connector OBM connector AUI connector AP NI FI FDDI QM LKG-7319-92I 3.2 Connecting the ThinWire Cable The ThinWire connector on the bridge (models in the DECbridge 500 Series) is located on the NI module. To install the ThinWire cable, determine whether your bridge is installed in the middle of a ThinWire segment or at the end of a segment and follow the procedures in Section 3.2.1 (for the middle of a segment) or Section 3.2.2 (for the end of a segment). 3–2 DECbridge 500/600 Series Installation and Upgrade 3.2.1 Connecting to the Middle of a ThinWire Segment To connect the DECbridge 500/600 Series unit to the middle of a ThinWire segment, perform the following steps: 1. Set configuration switch 8 on the AP module to OFF. This selects the ThinWire connection for Port 2. Refer to Appendix B for more switch information. 2. Locate the T-connector supplied in the shipping package and install it on the NI module connector. Push down and turn the collar on the cable connector a quarter turn clockwise to secure the connector in place. 3. Attach both ThinWire cables to the T-connector. Note the alignment slots on the end of the cable connector and align them with the tabs on the T-connector. Secure the connection for each cable by turning the collar on the connector a quarter turn. 4. Verify that the other ends of these cables are properly terminated (connected to a terminator, Digital Multiport Repeater (DEMPR), or equivalent device). If it is not connected, refer to the appropriate device documentation for connection information. 3.2.2 Connecting to the End of a ThinWire Segment To connect the DECbridge 500/600 Series unit to the end of a ThinWire segment, perform the following steps: 1. Set configuration switch 8 on the AP module to OFF. This selects the ThinWire connection for Port 2. Refer to Appendix B for more switch information. 2. Remove and save the terminator from the T-connector attached to the last station on the existing ThinWire segment. 3. Attach one end of the new ThinWire cable to the T-connector on the last station. Attach the other end of the cable to the T-connector for your bridge (supplied in the shipping package). 4. Attach the 50-ohm terminator to the T-connector on your bridge (see Figure 3–2). Note the alignment slots on the end of the cable connector and align them with the tabs on the T-connector. Secure the connection by turning the collar on the connector a quarter turn. Connecting Communications Cables and Verifying Bridge Operation 3–3 5. Install the ThinWire cable (with T-connector) onto the NI module connector. Push down and turn the collar on the cable connector a quarter turn clockwise to secure the cable in place. Your unit is now the last station on the ThinWire segment. Figure 3–2: ThinWire Cable Connector NI board ThinWire cable Tabs Collar Slots LKG-4861-93I 3.3 Connecting the AUI Cable The NI module has the AUI connector(s) for a DECbridge 500/600 Series unit (see Figure 3–1). If you have a DECbridge 600 Series unit, the NI module has three AUI connectors and no ThinWire connector. 3–4 DECbridge 500/600 Series Installation and Upgrade To install the AUI cable(s): 1. For DECbridge 500 Series units with one AUI connector on the NI module, verify that switch 8 on the AP module is set to ON to select AUI interface for Port 2. For DECbridge 600 Series units with three AUI connectors on the NI(3) module, switch 8 does not apply. Refer to Appendix B for more switch information. 2. Push the AUI connector slide latch on the NI module to the right to unlock the latch. 3. Plug the AUI cable connector into the AUI connector on the NI module (see Figure 3–3). NOTE The AUI cable connector can be installed in only one position. Check the alignment of the AUI connector before plugging in the cable. 4. Push the slide latch to the left until it snaps into the locking position, securing the connector. Connecting Communications Cables and Verifying Bridge Operation 3–5 Figure 3–3: AUI Connector Slide Latch AUI connector Push slide latch firmly to left to lock cables in place. LKG-4862-93I 5. Verify that the other end of this cable is connected to an H4000, H4005, or equivalent transceiver. If it is not connected, refer to the appropriate device documentation for connection information. 6. Repeat steps 2 through 5 for each AUI cable/connector. All AUI cableconnections are complete. If you are connecting the bridge to an FDDI network, proceed to Section 3.4 to install the FDDI fiber cable. If you do not have an FDDI interface (Model 600), all cables to the DECbridge unit, except the ac power cord, are now installed. Proceed to Section 3.6 for power-cord installation and unit-verification procedures. 3–6 DECbridge 500/600 Series Installation and Upgrade 3.4 Connecting the FDDI Cable The DECbridge 500/600 Series units have zero (null), one, or two FDDI connectors, depending on the model. The connectors are located on the FI module (see Figure 3–1). A single connector (SAS version of the bridge; S-type connector) is called Port 1. Two connectors (DAS version of the bridge) are called Port 1, connector type A (Port 1 [A]) and Port 1, connector type B (Port 1 [B]) (see Figure 3–4). The connector interface types are multimode, single-mode, or a combination of multimode and single-mode. Appendix B contains FDDI connector keying guidelines. WARNING ! Some fiber optic equipment can emit laser light that can injure your eyes. Never look into an optical fiber, cable connector, or port connector. CAUTION ! Ensure that the bend radius of any fiber optic cable is 2.5 centimeters (1 inch) or greater. NOTE Digital recommends you use Digital’s multimode FDDI-to-FDDI patch cables (BN24B-nn) or FDDIto-2.5-mm ST-type connector patch cables (BN24Dnn) for multimode connections. NOTE The FDDI multimode connector receptacles are keyed. Determine proper alignment of the connectors before attempting cable installation. Refer to Appendix B for more information on connector keying. 3.4.1 Connecting an FDDI Cable with a Multimode Connector To install an FDDI cable with a multimode connector: 1. Remove the protective device from the FDDI connector receptacle by squeezing the locking clips on the sides of the insert and pulling it out (see Figure 3–4). Connecting Communications Cables and Verifying Bridge Operation 3–7 2. Insert the FDDI cable connector into the module receptacle (with proper keying), ensuring the locking clips on the sides snap into the locked position (see Figure 3–4). 3. Verify that the other end of this cable is connected to the concentrator (such as the DECconcentrator 500 unit) if you are connecting to the dual ring through a concentrator. If it is not connected, refer to the appropriate concentrator manual or the Fiber Distributed Data Interface Network Configuration Guidelines manual for connection information. NOTE A DECbridge unit can be cabled to a patch panel first but must then be cabled from the panel to the appropriate concentrator or connected directly to an FDDI ring to complete proper connection of the bridge. 3.4.1.1 Installing the Optical Bypass Switch If you are installing a DAS multimode bridge and you are using the optical bypass feature, refer to the installation instructions included with the optical bypass switch to install the switch. All cables to the DECbridge unit, except the ac power cord, are now installed. Proceed to Section 3.6 to install the power cord and verify unit operation. 3–8 DECbridge 500/600 Series Installation and Upgrade 3.4.2 Connecting an FDDI Cable with a Single-mode Connector To install an FDDI cable with a single-mode connector: 1. Remove the two protective caps from the FDDI connectors on the FI module and from the end of the FDDI cable by turning them counterclockwise (see Figure 3–4). CAUTION ! Do not touch fiber ends; doing so may cause optical power loss. 2. Connect the fiber optic cable to the appropriate connectors and secure them by turning the collar on each connector clockwise. Transmit and receive icons are marked on the handle of single-mode connectors (see Figure 3–4). 3. Verify that the other end of this cable is connected to a concentrator, such as the DECconcentrator 500 unit or connected to the dual ring. If it is not connected, refer to the appropriate concentrator manual or the Fiber Distributed Data Interface Network Configuration Guidelines manual for connection information. Connecting Communications Cables and Verifying Bridge Operation 3–9 Figure 3–4: FDDI Cable Connectors Port 1 (B) Port 1 (A) Multimode connector Single-mode connectors LKG-4864-93I 3–10 DECbridge 500/600 Series Installation and Upgrade 3.5 Connecting the OBM Cable You need to install the Out of Band Management (OBM) cable when you want to use LCM and OBM. You can connect the OBM cable either directly to a terminal or through a Scholar modem (or equivalent device). You do not need this cable for normal unit operation. If you do not intend to use LCM and OBM, proceed to Section 3.6. Refer to Chapter 4 for information on using LCM. Recommended cables and passive adapters are provided in the following list and shown in Figure 3–5. • For VT100 or VT200 Series — Digital recommends using P/N BC22Dxx cables with 25-pin connectors at each end. If you use P/N BC16E-xx cables, use a passive adapter (P/N H8575A) at each end of the cable. • For VT300 or VT400 Series — Digital recommends using the standard six-pin modular jack (MJ6) connector cable P/N BC16E-xx. Use the passive adapter H8575A on the bridge end of the cable. Figure 3–5: Recommended Connections for the OBM Cable BC22D H8575A H8575A BC16E BC16E BC22E H8575A VT100 or VT200 VT100 or VT200 VT300 or VT400 Modem LKG-7314-92I Connecting Communications Cables and Verifying Bridge Operation 3–11 3.5.1 Connecting the OBM Cable Directly to a Terminal To connect the OBM cable directly to a terminal, perform the following steps: 1. Connect one end of the cable between the terminal and bridge to the 25-pin OBM connector on the AP3 module (see Figure 3–6). Secure the connector by tightening the screws on both sides of the connector. 2. Connect the other end of the cable to the terminal. Figure 3–6: Connecting the OBM Cable OBM connector LKG-7409-92I 3.5.2 Connecting the OBM Cable Through a Modem to a Terminal To connect the OBM cable through a modem to a terminal, perform the following steps: 1. Connect the cable between the modem and bridge to the 25-pin OBM connector on the AP3 module (see Figure 3–6). Secure the connector to the port by tightening the screws on both sides of the connector. 3–12 DECbridge 500/600 Series Installation and Upgrade 2. Connect the other end of the cable to the modem. 3. Ensure that the remote modem is connected to the terminal. 4. Ensure that both modems are connected to the telephone network. All cables to the DECbridge unit, except the ac power cord, are now installed. Proceed to Section 3.6 to install the power cord and verify unit operation. 3.6 Verifying Bridge Operation Verifying the bridge operation after installation or upgrade consists of powering up the bridge and observing the LED indicators. If the LEDs indicate a normal condition, your unit is working properly. If the LEDs indicate a problem, refer to the problem-solving procedures in Chapter 5. All communications cables should now be installed. If not, refer to the appropriate cable installation instructions (for your configuration) in this chapter. NOTE The DECbridge 500/600 Series units do not have a power ON/OFF switch. When the power cord is plugged in, power is applied directly to the bridge. 3.6.1 Powering Up When the power cord is first plugged in, all of the bridge LED indicators light for a 2-second lamp check. The bridge then performs internal self-test to verify that the unit is operating properly. The indicator LEDs turn on and off during this testing, according to the internal testing sequence. Be prepared to observe the LEDs on the I/O panel when plugging in the power cord to ensure the unit is working properly. To connect the bridge power cord, perform the following: WARNING ! Be sure to connect the power cord to a grounded wall outlet. 1. Connect one end of the bridge power cord into the DECbridge unit ac power connector (see Figure 3–7). Connecting Communications Cables and Verifying Bridge Operation 3–13 2. Connect the other end of the power cord into the ac wall outlet. 3. Observe the indicator LEDs and, once testing is complete (about 1 minute), compare the LEDs to those shown in Figure 3–7. The following LED states should appear and indicate that the unit is working properly: NOTE Wait until testing is complete before viewing the LEDs. FWD LEDs take longer to light than the other LEDs. • No LEDs are lit RED. A red LED indicates an error condition. • MODE on the AP3 module is ON (SOLID GREEN). • DC_OK on the AP3 module is ON (SOLID GREEN). • EXT_PWR on the NI or NI(3) module is ON (SOLID GREEN). • FWD2 (also FWD3 and FWD4 if applicable) on the NI or NI(3) module is ON (solid green). If a port is in backup state, the LED remains OFF. • AUI_SELECT on the NI module is ON (SOLID GREEN) for DECbridge 500 Series units if configuration switch 8 is selected to ON (AUI connection to network), or the LED is OFF if configuration switch 8 is selected to OFF (ThinWire connection to network). There is no AUI_SELECT LED for DECbridge 600 Series units (NI(3) module is installed). • FWD1 on the SAS and DAS versions of the FI module is ON (SOLID GREEN). If the port is in backup state, the LED remains OFF. • PHY (on FI module) for Port 1 on SAS versions of the bridge and PHY 1 for Port 1 (A) and PHY 2 for Port 1 (B) on DAS versions of the bridge blinks GREEN until fiber interface connection is made and then turns ON (SOLID GREEN). • ACT2 (also ACT3 and ACT4 if applicable) on the NI or NI(3) module and ACT1 on the SAS and DAS versions of the FI module flash ON and OFF (YELLOW) as packets are transmitted and received. • If the bridge is in a dual homing configuration, PHY1 blinks GREEN and RED. If the LEDs do not match (another condition appears), refer to the troubleshooting procedures in Chapter 5. 3–14 DECbridge 500/600 Series Installation and Upgrade Figure 3–7: DECbridge Unit Indicator LEDs After Power Up AC power connector AP NI FI QM LED Indicators AP3 NI 2 AUI 2 NI(3) 3 4 Null FI SAS 1 DAS 1 PHY 1 A PHY 1 B PHY 2 QM Legend – On – Off – Flashing – On or Off LKG-7331-92I Connecting Communications Cables and Verifying Bridge Operation 3–15 3.7 Checking the Logical Link To check the logical link, connect a host station on one side of the bridge to a host station on the other side of the bridge. On a VMS host running DECnet, use the SET HOST command. On an ULTRIX/UNIX host, use the rlogin command. In a TCP/IP environment, ping a station on the other side of the bridge. On an MS-DOS, Windows NT, or OS/2 PC running Novell NetWare as a network client, use the slist command. If you have problems connecting, refer to Chapter 5 for additional information. 3.8 Final Procedures Before leaving the site, perform the following: 1. Have the system/network manager record and save address information about the bridge (bridge location and bridge addresses). This information is helpful should a network problem occur. 2. Have the system/network manager record the current bridge parameters using your Network Management Software (NMS) and save them for future reference. When configuration switch 2 (Restore Default Parameters) is selected to ON, current bridge parameters are discarded and default bridge parameters are restored on power up. Refer to your network management software (NMS) manual for more information on retrieving current parameters from the bridge. 3. If you performed an upgrade of the AP module, remember to load previously saved parameters. 4. Dress the cables in a rackmount by using the guidelines supplied in the DECconnect System Fiber Optic Installation manual. 5. Verify that the site is clean. Remove or store all boxes and packaging materials. 6. Verify that all paperwork is completed. Installation or upgrade of the DECbridge unit is now complete. 3–16 DECbridge 500/600 Series Installation and Upgrade 4 Using Local Console Management This chapter describes Local Console Management (LCM) and shows how to access and display the LCM menu. It also explains how to use LCM to set attributes in the bridge, and how to change from the LCM interface to the Serial Line Internet Protocol (SLIP) interface to use network management software (NMS) for full bridge management. Any SNMP-compliant NMS which supports a SLIP connection can be used for full out-of-band management of the bridge. 4.1 Introduction LCM is a terminal-based facility that allows limited management of the DECbridge 500/600 Series units. It requires no special management station or software. You can connect a terminal directly to the 25-pin OBM connector on the AP3 board or through a Scholar modem (or equivalent device). If your personal computer (PC) has terminal emulation, you can access LCM by connecting the PC directly to the OBM port. NOTE Using LCM is optional and is not necessary for the operation of the bridge. You can also use the OBM port for full NMS bridge management. In this mode of operation, an SNMP network management system can communicate with the unit by using SLIP. This allows full management of the unit through a communication channel that is separate from the FDDI and NI data channels. To enter this mode of operation from LCM, use the SET SLIP MODE option on the LCM screen. Alternately, if LCM receives a SLIP packet (at the correct baud rate), the OBM port switches to SLIP MODE. Figure 4–1 shows the modes of operation and access methods for OBM. 4–1 Figure 4–1: Access Methods for OBM OBM ASCII Interface LCM SLIP Interface NMS LKG-8041-93I 4.2 Accessing LCM To access LCM, first connect a terminal to the bridge. Then, perform the following steps: 1. Set your terminal to a 9600-baud rate and 8 bits/no parity/1stop bit. 2. Ensure one end of the terminal or modem cable is connected to the 25-pin connector on the AP3 module. 3. Power up the bridge. After completing bridge self-test (about 1 minute), the terminal displays the LCM Menu (see Example 4–1). If the screen does not display the LCM menu, press RET . 4–2 DECbridge 500/600 Series Installation and Upgrade Example 4–1: Displaying the LCM Screen DECbridge 500 Series Local Console Management IP Address: 16.21.16.128 Trap Address Table: 16.21.16.200 16.21.16.225 0.0.0.0 0.0.0.0 Seconds Operating: 215 FDDI Frame Count: FDDI Error Count: FDDI Ring Inits: 65237176 0 1 Set SLIP mode: off V1.3 Default Gateway Address: 16.21.16.227 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 Number of Resets: 14 Current Baud Rate: 9600 Power-up Baud Rate: 9600 CTRL-R To Refresh Screen >IP Address: Enter new value or 0 to delete 4.2.1 Attributes Displayed When Using LCM The LCM screen displays attributes and system messages. When you power up the bridge for the first time, the IP Address field, the Default Gateway Address field , and the Trap Address Table display all zeros. After you set the values, the screen displays set values when you recycle power. Refer to Section 4.4 for information on setting attribute values. The screen displays the following attributes: • IP Address — The bridge’s Internet Protocol address. • Default Gateway Address — The Internet address of the default IP gateway for the bridge. Using Local Console Management 4–3 • Trap Address Table — Displays the addresses to which the bridge sends SNMP traps. It displays up to eight trap addresses. When you enter a value into one of the eight fields, the screen displays the value in the first available field that contains a zero value. • Seconds Operating — Number of seconds since the bridge was reset (read only). • Number of Resets — Number of times the device has reset due to one or more of the following conditions (read only): – Power up – Internal reset due to an error condition – Command from network management • FDDI Frame Count — Total number of FDDI frames received on the line, including those frames that were stripped from the ring and those that were merely repeated (read only). • FDDI Error Count — Number of error frames detected by the line; that is, the number of times the FDDI MAC entity changed the E (error detected) field in a frame from R to S (set). This total does not include error frames that were previously detected by other stations on the ring (read only). • FDDI Ring Initializations — The number of times the FDDI MAC entity attempted to connect to the logical ring (read only). • Set SLIP MODE — Allows you to change from LCM to SLIP MODE to use NMS. NOTE Once you set SLIP MODE, you can return to LCM only by resetting the bridge through management or powering the bridge down and bringing it up again. 4–4 • Current Baud Rate — Allows you to set the currently active baud rate of the serial port. If you change this parameter, you must also change the terminal baud rate. • Initial Baud Rate — Allows you to set the initial baud rate of the serial port when it is powered up or reset. DECbridge 500/600 Series Installation and Upgrade 4.3 Messages Displayed The following messages are displayed: • CTRL/R to Refresh Screen – Special key definition that allows you to re- fresh the screen. Pressing CTRL/W also refreshes the screen. • System messages appear at the bottom of the screen. 4.4 Setting the Attribute Values When you power up the DECbridge 500/600 Series unit, the cursor appears in the Internet Protocol (IP) Address field. To change the attributes on the LCM screen, perform the following steps: 1. Move the cursor to the desired attribute field: – To move to the next field, press the down arrow key or the right arrow key on the keypad or press RET . – To move to the previous field, press the up arrow key or the left arrow key on the keypad. 2. Enter the data. If you enter incorrect data, press DEL to erase it. 3. When the data in the field is correct, press RET . The screen displays the new data in the field (and updates NVRAM). If you enter invalid data, an error message appears at the bottom of the screen. When you move the cursor through the attribute fields, it skips read-only fields. These fields automatically update every five seconds. 4.5 Switching from LCM to SLIP MODE When you select SET SLIP MODE, the screen prompts you to ensure that you want to switch to this mode. Once you switch to SLIP MODE, you can return to LCM only by recycling bridge power or resetting the bridge through management. Using Local Console Management 4–5 To switch to SLIP MODE, perform the following steps: 1. Move the cursor to the SET SLIP MODE option on the screen. The field displays OFF. 2. Type ON, and press RET . The screen prompts you, ‘‘Are you sure you want to switch to SLIP?” 3. Enter Y on the keyboard. 4. Disconnect the cable from the terminal to the bridge. 5. Connect the cable from the network management station to the bridge. NOTE If a SLIP packet arrives at the OBM port (in LCM mode), it automatically switches to SLIP MODE. Some packets may be lost in the switchover. Baud rates must be the same value for SLIP MODE and LCM. 4–6 DECbridge 500/600 Series Installation and Upgrade 5 Solving Problems This chapter helps identify and correct problems you may have installing or upgrading the DECbridge 500/600 Series unit. The troubleshooting procedures provided are for diagnosing and correcting hardware-related problems only. After diagnosing and correcting a problem, return to Chapter 3 to verify that the unit is operating properly. NOTE Notify the system/network manager if the troubleshooting procedures indicate a problem related to the software or if the basic troubleshooting procedures do not correct the problem. NOTE You must use DECbridge firmware version 1.3 or higher when an AP3 module is installed in your bridge. 5.1 Basic Troubleshooting The bridge LEDs show the status of the unit and help diagnose problems. After powering up and allowing time for the bridge to perform diagnostic testing, the LEDs indicate whether the unit is functioning properly. 5–1 When the self-test diagnostics detect a failure in the bridge (or you suspect a failure), rerun self-test to verify that the failure can be repeated. You can run self-test locally by unplugging the ac power cord and plugging it back in (recycles power and starts self-test). 5.1.1 Determining Symptoms and Following Corrective Actions After determining the symptom of a problem, find the symptom listed in Table 5–1 and follow the steps for corrective action. After taking corrective actions, return to Chapter 3 and verify proper bridge operation. If the problem is still not resolved, refer to the DECbridge 500/600 Series Problem Solving manual for additional help. If the problem exists after further troubleshooting, call your Digital Services representative. Table 5–1: Symptoms LED Indicator Symptoms and Corrective Actions Corrective Action General All LEDs off. Verify that the ac power cord is plugged in correctly at the ac connector on the bridge and the ac wall outlet. Verify that the ac wall outlet is working properly and is of the correct voltage. Determine whether the bridge’s circuit breaker has tripped. If it has, press in the white center portion of the breaker to reset it. If the circuit breaker trips more than once, notify the system/ network manager. Check that the bridge’s configuration switches are set correctly. Refer to Appendix B for switch descriptions. Ensure that the fans are running. If they are not, an overtemperature condition may have induced a logic module failure or a power-supply problem. Make sure all modules are installed properly, all ejectors secured, and all screws tightened. Consider possible environmental problems such as power fluctuations, high ambient temperature, interference from other equipment, and so on. 5–2 DECbridge 500/600 Series Installation and Upgrade Table 5–1 (Cont.): LED Indicator Symptoms and Corrective Actions Symptoms Corrective Action All LEDs remain on. Verify that all modules are installed properly into the backplane connectors. Retry power-up procedures. All FRU_BAD LEDs are Improper upgrade of modules. Contact Digital Services for blinking. information on upgrades. A logical link cannot be created. Verify that all cables are installed and connected properly. Check switch settings. Verify that the node at the other end of the link is working. AP Module LEDs AP BAD remains on. Self-test failed. Retry bridge self-test. Incompatible firmware loaded. Call Digital Services to replace the AP3 module. AP BAD blinking. Incompatible firmware loaded. Call the system/network manager. Do not load the AP3 module with a previous version of firmware lower than Version 1.3. Call Digital Services to upgrade the incompatible module. NI Module LEDs NI BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the NI module. FWD2 blinking. Port 2 (AUI/ThinWire) in broken state. Check cable connections. If cable connections are not the problem, perform the loopback test in this chapter. EXT PWR OK remains off. Transceiver power failure. Check cable connections. Check cables for possible faulty wiring (shorts). Solving Problems 5–3 Table 5–1 (Cont.): LED Indicator Symptoms and Corrective Actions Symptoms Corrective Action NI BAD blinking. Incompatible firmware loaded. manager. Call the system/network Do not load the AP3 module with a previous version of firmware lower than Version 1.3. Call Digital Services to upgrade the incompatible module. NI(3) Module LEDs 5–4 NI BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the module. FWD2 blinking. Port 2 (AUI) in broken state. Check cable connections. If cable connections are not the problem, perform the loopback test in this chapter. FWD3 blinking. Port 3 (AUI) in broken state. Check cable connections. If cable connections are not the problem, perform the loopback test in this chapter. FWD4 blinking. Port 4 (AUI) in broken state. Check cable connections. If cable connections are not the problem, perform the loopback test in this chapter. EXT PWR OK remains off. Transceiver power failure. Check cable connections. Check cables for possible faulty wiring (shorts). NI BAD blinking. Incompatible firmware loaded. Call Digital Services to upgrade the incompatible module. DECbridge 500/600 Series Installation and Upgrade Table 5–1 (Cont.): LED Indicator Symptoms and Corrective Actions Symptoms Corrective Action SAS FI Module LEDs FI BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the module. FI BAD blinking. Incompatible firmware loaded. Call the system/network manager. Do not load the AP3 module with a previous version of firmware lower than Version 1.3. Call Digital Services to upgrade the incompatible module. FWD1 blinking. Port 1 (FDDI) in broken state. Check all cable connections. If cable connections are not the problem, perform the loopback test in this chapter. PHY 1 blinking (red). Illegal topology. Check the configuraton setup and verify proper connections and cabling. Also notify the system manager. PHY 1 ON (red) (and FI BAD LED on). Port broken. Perform the loopback test in this chapter. If connection is OK with loopback test, check for cable problems at FDDI port or at other end of cable. PHY 1 ON (red) (and FI BAD LED off). Solving Problems Port failed Line Confidence Test. Perform the loopback test in this chapter. 5–5 Table 5–1 (Cont.): LED Indicator Symptoms and Corrective Actions Symptoms Corrective Action DAS FI Module LEDs FI BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the module. FI BAD blinking. Incompatible firmware loaded. Call the system/network manager. Do not load the AP3 module with a previous version of firmware less than Version 1.3. Call Digital Services to upgrade the incompatible module. FWD1 blinking. Port 1 (FDDI) in broken state. Check all cable connections. If cable connections are not the problem, perform the loopback test in this chapter. PHY 1 blinking (red). Illegal topology. Check the configuraton setup and verify proper connections and cabling. Also notify the system manager. Check that the loopback connector is removed and the FDDI cable is installed properly. PHY 1 blinking (red/green). Port is in standby mode as part of a dual-homed configuration. No corrective action is required. Check that the loopback connector is removed and the FDDI cable is installed properly. PHY 1 on (red) (and FI BAD on). Port broken. Perform the loopback test in this chapter. If connection is OK with loopback test, check for cable problems at FDDI port or at other end of cable. PHY 1 on (red) (and FI BAD off). 5–6 Port failed Line Confidence Test. Perform the loopback test in this chapter. DECbridge 500/600 Series Installation and Upgrade Table 5–1 (Cont.): LED Indicator Symptoms and Corrective Actions Symptoms Corrective Action PHY 2 blinking (red). Illegal topology. Check the configuraton setup and verify proper connections and cabling. Also notify the system manager. Check that the loopback connector is removed and the FDDI cable is installed properly. PHY 2 ON (red) (and FI BAD on). Port broken. Perform the loopback test in this chapter. If connection is OK with loopback test, check for cable problems at FDDI port or at other end of cable. PHY 2 ON (red) (and FI BAD off). Port failed Line Confidence Test. Perform the loopback test in this chapter. Null FI Module LEDs FI BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the module. FI BAD blinking. Incompatible firmware loaded. manager. Call the system/network Do not load the AP3 module with a previous version of firmware less than Version 1.3. Call Digital Services to upgrade the incompatible module. QM Module LEDs QM BAD remains on. Self-test failed. Retry bridge self-test. Call Digital Services to replace the module. QM BAD blinking. Incompatible firmware loaded. manager. Call the system/network Do not load the AP3 module with a previous version of firmware less than Version 1.3. Call Digital Services to upgrade the incompatible module. Solving Problems 5–7 5.1.2 Port Loopback Testing If diagnostic results indicate a port interface problem, perform a loopback test on that interface to determine if the fault is in the bridge, in the interface cable, or in the device connected to the bridge. When the Manufacturing Mode switch (configuration switch 1) and the Enable External Loopback switch (configuration switch 7) are both ON , the self-test diagnostics test both the FI module (SAS and DAS versions) and NI or NI(3) module ports (providing the loopback connectors are installed). The diagnostics test the optical bypass relay driver but not the bypass switch. WARNING ! To prevent personal injury or equipment damage, do not insert telecommunications cables into the optical bypass relay connector. If the FI module port fails self-test, the FI_BAD indicator turns on. If the NI or NI(3) module ports fail self-test, the NI_BAD indicator turns on. 5.1.2.1 Installing the Loopback Connectors When performing port loopback testing, always place loopback connectors on both the FI module (Port 1) and NI module (Port 2) ports. Perform loopback testing of the FI module port (SAS and DAS, multimode and single-mode) by using a simple fiber loop housed in an FDDI connector for multimode connectors or using a single-mode attenuated loopback for a single-mode connector. These loopback connectors route the output of the fiber optic transmitter in that port back into the fiber optic receiver. External loopback testing of the NI port for DECbridge 500 Series units checks both the AUI and ThinWire interfaces but reports only the results of interface selected by the AUI/ThinWire switch (configuration switch 8). A detected failure in the selected interface lights the NI_BAD indicator. External loopback testing of the NI(3) ports for DECbridge 600 Series units checks the AUI interfaces. There is no ThinWire port and switch 8 has no effect on the results reported. 5–8 DECbridge 500/600 Series Installation and Upgrade To install the loopback connectors on NI and FI ports and prepare the unit for loopback testing, perform the following four steps: 1. Remove power to the bridge by disconnecting the power cord from the ac outlet. 2. Ensure the Manufacturing Mode switch (configuration switch 1) is OFF (up) and the Enable External Loopback switch (switch 7) to the ON (down) position. 3. Remove the FDDI port cable(s) from the FI module and install the following loopback connector(s), as shown in Figure 5–1: – For FDDI multimode connector(s), install the multimode loopback connector (P/N 12–32005–01). – For FDDI single-mode connector(s), install the single-mode attenuated loopback connector(s) (P/N 12–34830–01). NOTE If a loopback connector is not installed or there is no 802.3/Ethernet network connection and the Enable External Loopback switch is ON, self-test fails. 4. Remove the AUI or ThinWire interface cable(s) from the NI or NI(3) module and install the following loopback connector(s), as shown in Figure 5–2: – For NI ThinWire connectors, install the T-connector (PN12-25869-01) and two terminators (P/N 12-26318-01) on the ThinWire port. – For NI or NI(3) AUI connector(s), install the AUI loopback connector(s) (P/N 12–22196–01). NOTE For DECbridge 500 Series models, make sure the AUI/ ThinWire switch (configuration switch 8) is in the correct position: ON (down) for testing the AUI interface and OFF (up) for testing the ThinWire interface. Solving Problems 5–9 Figure 5–1: Installing the FDDI Loopback Connectors Single-mode attenuated loopback connector Multimode loopback connector LKG-4867-93I 5–10 DECbridge 500/600 Series Installation and Upgrade Figure 5–2: Installing the NI Loopback Connectors Push slide latch firmly in place to lock connector in place. Tabs Slots LKG-4868-91I Solving Problems 5–11 5.1.2.2 Running the Loopback Test and Observing the Results To run the loopback test and observe results, perform the following three steps: 1. Reconnect the power cord to the ac outlet. 2. Observe the LED indicators on the FI module after the self-test diagnostic is complete (about 30 seconds) and loopback testing starts. – If the FDDI port fault does not light, the problem is probably external to the bridge. Check the interface cable and the device connected to the other end of the cable. – If the FDDI port fault indication (FI_BAD) still exists (SOLID RED) and the AP_BAD LED is flashing, the problem is in the bridge. It may indicate the FI module is bad. Verify that the FI module is properly installed. If the module is installed properly, refer to the DECbridge 500/600 Series Problem Solving manual for more information on troubleshooting. 3. Observe the NI_BAD indicator on the NI or NI(3) module. 5.1.2.3 – If the NI_BAD indicator turns off, the problem is external to the bridge. Check the interface cable and the device connected to the other end of the cable. – If the NI_BAD indicator lights (the NI_BAD LED on the NI module flashes; the NI_BAD LED on the NI(3) module is SOLID RED) and the AP_BAD LED is flashing, the problem is in the bridge. It may indicate the NI module is bad. Verify that the NI or NI(3) module is properly installed before consulting the DECbridge 500/600 Series Problem Solving manual for more information on troubleshooting. Returning to Normal Operation When you have completed loopback testing of the ports, perform the following five steps to return the bridge to normal operation: 1. Disconnect the power cord from the ac outlet. 2. Set the Enable External Loopback switch (switch 7) to the OFF (up) position. 5–12 DECbridge 500/600 Series Installation and Upgrade 3. Remove the NI loopback connector(s) and reconnect the NI interface cable(s). Refer to Chapter 3 if necessary. 4. Remove the FDDI loopback connector(s) and reconnect the FDDI interface cable(s). Refer to Chapter 3 if necessary. 5. Reconnect the power cord to the ac outlet to resume normal operation. Solving Problems 5–13 A DECbridge 500/600 Series Models The models for the DECbridge 500/600 Series of bridges are listed in Table A–1. The table includes a description of the modules and interface for each model. Note that the U.S./Canada versions (for example, DEFEB-AC) are the only versions that ship with a power cord included. The versions for other countries (for example, DEFEB-AD) require a separate power cord kit designed for specific country installations. These power cord kits are ordered separately. Table A–2 lists the power cord kits. A–1 Table A–1: DECbridge 500/600 Series Models Model Number Part Number* Description and Modules DECbridge 500 DEFEB-AA/AB Single Attachment Station unit with AP module, NI1 module, FI module with multimode optics, and QM module DECbridge 500 Series A–2 DECbridge 510 DEFEB-AC/AD Single Attachment Station unit with AP3 module, NI1 module, FI module with multimode optics, and QM module DECbridge 518 DEFEB-AS/AT Single Attachment Station unit with AP3 module, NI1 module, FI module with single-mode optics, and QM module DECbridge 520 DEFEB-DA/DB Dual Attachment Station unit with AP3 module, NI1 module, FI module with multimode optics and control for optical bypass relay, and QM module DECbridge 524 DEFEB-DM/DN Dual Attachment Station unit with AP3 module, NI1 module, FI module with single-mode (Port 1 A)/ multimode optics (Port 1 B), and QM module DECbridge 526 DEFEB-DP/DQ Dual Attachment Station unit with AP3 module, NI1 module, FI module with multimode (Port 1 A)/single-mode optics (Port 1 B), and QM module DECbridge 528 DEFEB-DS/DT Dual Attachment Station unit with AP3 module, NI1 module, FI module with single-mode optics, and QM module DECbridge 500/600 Series Installation and Upgrade Table A–1 (Cont): DECbridge 500/600 Series Models Model Number Part Number* Description and Modules DECbridge 600 Series DECbridge 600 DEFEB-UA/UB Multiport Ethernet bridge with AP3 module, NI(3) module, Null FI module (no FI port), and QM module DECbridge 610 DEFEB-TA/TB Single Attachment Station unit with AP3 module, NI(3) module, FI module with multimode optics, and QM module DECbridge 618 DEFEB-TS/TT Single Attachment Station unit with AP3 module, NI(3) module, FI module with single-mode optics, and QM module DECbridge 620 DEFEB-LA/LB Dual Attachment Station unit with AP3 module, NI(3) module, FI module with multimode optics and control for optical bypass relay, and QM module DECbridge 624 DEFEB-LM/LN Dual Attachment Station unit with AP3 module, NI(3) module, FI module with single-mode (Port 1 A)/multimode optics (Port B), and QM module DECbridge 626 DEFEB-LP/LQ Dual Attachment Station unit with AP3 module, NI(3) module, FI module with multimode (Port 1 A)/single-mode optics (Port 1 B), and QM module DECbridge 628 DEFEB-LS/LT Dual Attachment Station unit with AP3 module, NI(3) module, FI module with single-mode optics, and QM module *Part numbers indicate U.S./Canada model designations followed by the designations for other countries (for example, DEFEB-AC is designated for U.S./Canada and DEFEB-AD is designated for all other countries). DECbridge 500/600 Series Models A–3 A.1 DECbridge Modules The DECbridge units contain four modules that control the functions of the bridge: the AP module, NI module, FI module, and QM module. The AP module (versions AP, AP2, and AP3) controls the transmission and reception of the IEEE 802.3/Ethernet packet flow, and coordinates various bridge-management tasks such as the spanning tree process. The NI module provides the interface to the IEEE 802.3/Ethernet network. An NI module in the DECbridge 500/600 Series can have one or three AUI connectors, depending on the model. With three AUI connectors, there is no ThinWire connector. The FI module provides a SAS or DAS connection to the FDDI network. The DAS connection is multimode, single-mode, or both. The DAS multimode version of the FI module also provides control for an optical bypass relay. The optical bypass relay helps maintain FDDI ring integrity if a bridge within the FDDI ring breaks down or is powered down. The bypass, if used, is automatically activated on a broken bridge within an FDDI ring, continuing communication. The QM module services packets received from and transmitted to an FDDI network. The four module locations on the bridge are shown in Figure A–1. The module slots are labeled to help identify modules. NOTE The DECbridge 500 uses an AP module; all other models in the DECbridge 500/600 Series use an AP2 or AP3 module. NOTE You need bridge firmware version 1.3 or higher when using an AP3 module. A–4 DECbridge 500/600 Series Installation and Upgrade Figure A–1: DECbridge 500/600 Series Modules NI module NI 500 Series NI(3) 600 Series AP NI FI QM FI module Model Null 600 SAS multimode 500,510 610 SAS, single-mode 518, 618 DAS multimode 520, 620 DAS single-mode (A), multimode (B) 524, 624 DAS multimode (A), single-mode (B) 526, 626 DAS single-mode 528, 628 LKG-4855-93I DECbridge 500/600 Series Models A–5 Table A–2: Power Cord Kits Order Code Country BN20A-2E* United States, Canada BN20B-2E Japan BN20C-2E Australia, New Zealand BN20D-2E Belgium, Finland, France, Germany, Holland, Norway, Spain, Sweden BN20E-2E United Kingdom, Ireland BN20F-2E Switzerland BN20H-2E Denmark BN20J-2E Italy BN20K-2E India, South Africa BN20L-2E Israel *This kit ships with U.S./Canada models only. Power cord kits for units shipped to other countries are required for installation and must be ordered separately. A–6 DECbridge 500/600 Series Installation and Upgrade B Switches and Indicators The switches and indicators for the DECbridge 500/600 Series of bridges are located on the I/O panel of the bridge. Figure B–1 shows the switches and indicator LEDs on a bridge. Section B.1 and Section B.2 describe the switches and indicators and their functions. B.1 Configuration Switches The eight configuration DIP switches on the DECbridge 500/600 Series unit are located on the AP3 module (see Figure B–1). Switch 1 is the leftmost switch (as you face the I/O panel). These switches are set during installation of the bridge and control several settable functions of the bridge. B–1 Figure B–1: Configuration Switches and LED Indicators Off Configuration switches On 1 2 3 4 5 6 7 8 AP NI FI QM LED Indicators AP3 NI R R R Y R G G 2 G AUI G G G 2 NI(3) Null FI SAS DAS QM Y 3 G Y 4 G Y G R R 1 Y G R 1 Y G PHY 1 G PHY 1 A G PHY 2 B G R LKG-7324-92I B–2 DECbridge 500/600 Series Installation and Upgrade The configuration switches for the bridge (listed in Table B–1) have the following functions: • Manufacturing mode switch (Switch 1) — This switch should always be in the OFF (up) position for normal operating mode. Manufacturing mode is only for use in a manufacturing environment or repair station. The firmware reads this switch only during initialization. • Restore default parameters switch (Switch 2) — This switch is normally in the OFF (up) position. Turning it ON resets all parameters defined by bridge management and replaces them with the default factory settings. The firmware reads this switch only during initialization; therefore, you must recycle power to the bridge whenever you change the switch setting or wish to load default settings. • Write access switch - Port 1 (Switch 3) — When this switch is ON, network stations connected to Port 1 (the IEEE 802.3/Ethernet port) that have bridge management capabilities are allowed to read and write (modify) bridge-management parameters. When this switch is OFF, those stations are allowed to read but cannot write bridge management parameters. The firmware checks the state of this switch whenever a write access to the bridge is attempted through Port 1. On the DECbridge 500 unit, this switch controls access to Port 2. • Write access switch - Port 2 (Switch 4) — Performs the same function as described for switch 3, but for Port 2 (FDDI port connectors A and B). On the DECbridge 500 unit, this switch controls access to Port 1. • Write access switch - Port 3 (Switch 5) — The setting for this switch applies only when a three-port NI(3) module is installed. It performs the same function as described for switch 3 (Port 1), but for Port 3. • Write access switch - Port 4 (Switch 6) — The setting for this switch applies only when a three-port NI(3) module is installed. It performs the same function as described for switch 3 (Port 1), but for Port 4. Switches and Indicators B–3 • • External loopback enable switch (Switch 7) — This switch should be OFF during normal bridge operation. Turning it ON allows the self-test diagnostics to perform external loopback tests on both Ports 1 and 2 (providing the external loopback connectors are in place). It also applies to Ports 3 and 4 when a three-port NI(3) module is installed. Since the firmware reads this switch only during initialization, you must recycle power to the bridge whenever you change the switch setting. AUI/ThinWire switch (Switch 8) — The settings for this switch apply when a one-port NI module is installed. They do not apply when a three-port NI(3) module is installed. When a one-port NI module is installed, this switch must be in the ON (down) position if Port 2 is connected to an AUI interface, or in the OFF (up) position if Port 2 is connected to a ThinWire interface. The firmware checks the state of this switch on a regular basis; therefore, changing this switch setting does not require recycling power to the bridge. Table B–1: Configuration Switches Factory Setting Switch Name 1 Manufacturing OFF mode Restore default OFF parameters Write access OFF (Port 1)1 Write access OFF (Port 2)1 Write access OFF (Port 3)2 Write access OFF (Port 4)2 External OFF loopback enable AUI/ThinWire 3 OFF 2 3 4 5 6 7 8 ON (Down) OFF (Up) Select manufacturing Select normal mode operating mode Restore default Use current parameters on power up parameters Allow management write No management write access on Port 1 access on Port 1 Allow management write No management write access on Port 2 access on Port 2 Allow management write No management write access on Port 3 access on Port 3 Allow management write No management write access on Port 4 access on Port 4 Enable External Loopback Normal operation Test Select AUI connection for Port 2 Select ThinWire connection for Port 2 1 These switches are reversed on the DECbridge 500 unit. Switch 3 is for Port 2; Switch 4 is for Port 1. Also, Switches 5 and 6 are not used on the DECbridge 500 unit. 2 Not applicable when one-port NI module installed. 3 Not applicable when three-port NI(3) module installed. B–4 DECbridge 500/600 Series Installation and Upgrade B.2 Bridge LED Indicators The DECbridge 500/600 Series LED indicators are visible from the outside of the unit. Table B–2 describes the LEDs for all DECbridge 500/600 Series modules. The LEDS are located on each module to indicate functions associated with each module. The LEDs have the following meanings: • A Green LED indicates the presence of power and also shows port state. • A Red LED indicates a fault. • A Yellow LED indicates the presence of activity on the communication link. When the DECbridge 500/600 Series is first powered on (ac power cord plugged in), all LEDs light momentarily for a lamp check. The bridge then performs testing and the LEDs are turned off and on according to the testing sequence. Table B–2: LED Indicators LED Symbol Color Normal Description AP BAD Red Off On Off Blink -- Self-test failed -- Self-test passed -- Incompatible firmware loaded FAN BAD Red Off On Off -- Fan failure -- Fan OK MODE Green On On Off Blink -- Bridge operational -- Self-test in progress -- Downline load in progress DC OK Green On On Off -- DC power OK -- DC power failure Red Off On Off Blink -- Self-test failed -- Self-test passed -- Incompatible firmware loaded AP3 or AP Module: QM Module: QM BAD Switches and Indicators B–5 Table B–2 (Cont): LED Indicators LED Symbol Color Normal Description Red Off On Off Blink -- Self-test failed -- Self-test passed -- Incompatible firmware loaded Yellow On/Off On Off -- NI port(n) carrier present -- NI port(n) carrier not present Green On On Blink Off -- NI port(n) in forwarding state -- NI port(n) in broken state -- NI port(n) not forwarding, not broken (in preforwarding or backup state) AUI SELECT AUI Green (DECbridge 500 Series only) On/Off On Off -- NI port AUI interface selected -- NI port ThinWire interface selected EXT PWR OK On On -- AUI transceiver power OK (In DECbridge 500 Series, not affected by AUI/ThinWire switch) -- AUI transceiver power failure NI or NI(3) Module: NI BAD ACTn (n= 2, 3, or 4) n FWDn Green Off FI Module: (Note: FI Null Module has only the FI BAD indicator) FI BAD ACT1 FWD1 B–6 1 Red Off On Off Blink -- Self-test failed -- Self-test passed -- Incompatible firmware loaded Yellow On/Off On Off -- Valid traffic present -- Not transmitting/receiving valid packets Green On On Blink Off -- FDDI port in forwarding state -- FDDI port in broken state -- FDDI port not forwarding, not broken (in preforwarding or backup state) DECbridge 500/600 Series Installation and Upgrade Table B–2 (Cont): LED Indicators LED Symbol Color Normal Description PHY 1 (A) PHY 1 On On Blink On Green Green Red Red Blink Off Blink Red/green PHY 2 (B) PHY 2 (Only on DAS models) Green Green Red Red On On Blink On Blink Off -- PHY connection complete -- PHY connection in progress -- Broken port or Link Confidence Test (LCT) failure retry loop -- Illegal topology -- Port disabled via management -- Standby mode for this port when in a dual-homing connection to a concentrator -- PHY connection complete -- PHY connection in progress -- Broken port or Link Confidence Test (LCT) failure retry loop -- Illegal topology -- Port disabled via management B.3 Circuit Breaker The circuit breaker provides overcurrent protection for the bridge. If an overcurrent condition causes the circuit breaker to trip, the white center portion of the breaker pops out as a visual indication of the overcurrent condition. When this occurs, ac power is cut off from the bridge. Reset the circuit breaker by pushing in the white center portion of the breaker. B.4 Port Addressing The DECbridge 500/600 Series port addresses are listed on the AP3 module and are assigned as follows: • Address 1 — FDDI (Port 1) • Address 2 — Ethernet (Port 2, either connector on the NI module; left connector on the NI(3) module) • Address 3 — Ethernet (Port 3, middle connector on the NI(3) module) • Address 4 — Ethernet (Port 4, right connector on the NI(3) module) Switches and Indicators B–7 B.5 Optical Bypass Connector The optical bypass relay feature on the bridge maintains FDDI dual ring integrity if the bridge breaks or is powered down. The optical bypass connector is available only on the DAS multimode version of the FI module. Figure B–2 shows the bypass connector and provides a description of the connector pins. Refer to this information when selecting optical bypass devices. WARNING ! To prevent personal injury or equipment damage, do not insert telecommunications cables into the optical bypass relay connector. Figure B–2: Optical Bypass Control Signals FI DAS module R 1 Y A PHY 1 G G B PHY 2 G Pins 654 321 Modular jack (Shielded RJ12) Pin Description 1,2 3,4,6 5 Relay drive; +5V @ 200 mA (max.) Return; grounded internally Bypass present; must be externally grounded to pin 3,4, or 6 LKG-5186-93I B–8 DECbridge 500/600 Series Installation and Upgrade B.6 FDDI Connector Keying The connectors used on DECbridge 500/600 Series bridges for FDDI network connection are: • Media Interface Connectors (MIC) for multimode connections • FC/PC for single-mode connections The MIC connectors are designed to align the fiber cable properly with the transmit and receive optics — that is, they are keyed and must be aligned properly. The three types of connectors used on the bridge are MIC A and MIC B for DAS versions of the bridge and MIC S for SAS versions of the bridge (see Figure B–3). Note that the DECbridge units connect to a MIC M type connector on the DECconcentrator 500. Figure B–3: DECbridge 500/600 Series MIC Receptacle Keying Plugs A B M S B M S Receptacles A Connector keying: MIC A Primary in/secondary out–DAS A port MIC B Primary out/secondary in–DAS B port MIC M Concentrator M port MIC S SAS S port LKG-6859-92I The position of the keyway on the MIC plug determines the type of receptacle to which it connects. A MIC S plug fits all receptacles. The other MIC plugs and receptacles (type A and B) must match for proper installation. The FC/PC single-mode connectors are not keyed but are identified by transmit ( ) and receive ( ) icons. Switches and Indicators B–9 B.7 FDDI Connection Rules The FDDI connection rules are defined in Figure B–4. The table defines which port types (A, B, M, S) may be interconnected into legal topologies. In the figure, This Node is the reference point for all connection decisions. Figure B–4: FDDI Connection Rules Matrix This Node PHY port A A Other Node B M S No Rule 1 Yes Yes B Rule 2 No Yes Yes M Rule 3 Yes Note 1 No Yes S Yes Yes Yes Yes Yes = Accepts this connection No = Does not accept this connection LKG-4810-91I Rule 1: PHY B of This Node accepts connection to PHY A of Other Node if: • PHY A of This Node is not connected, or • PHY A of This Node is connected to PHY B or PHY S of another node. Rule 2: PHY A of This Node accepts connection to PHY B of Other Node if: • PHY B of This Node is not connected, or • PHY B of This Node is connected to PHY A or PHY S of another node. • See Note 2. B–10 DECbridge 500/600 Series Installation and Upgrade Rule 3: PHY A of This Node accepts the connection to PHY M of Other Node if: • PHY B of This Node is not connected, or • PHY B of This Node is connected to PHY A or PHY S of another node. • See Note 2. Note 1: Backup tree connection (dual homing) The connection of PHY B of This Node to PHY M of Other Node always takes precedence over the connection of PHY A of This Node to PHY M of another node. A connection between PHY A of This Node and a PHY M or PHY B of another node is disabled when PHY B of This Node connects to PHY M of Other Node. If the connection breaks between PHY B of This Node and PHY M of Other Node, the connection is reestablished between PHY A of This Node and PHY M of another node. Note 2: Tree connections are preferred over dual ring connections Tree connections are preferred over dual ring connections when only one of two connections can be accepted. The connection of PHY A or B of This Node to PHY M of Other Node always takes precedence over the connection of the remaining PHY (A or B) of This Node to PHY A or PHY B of another node. The connection is disabled between the remaining PHY (A or B) of This Node and PHY A or PHY B of another node when PHY A or PHY B of This Node connects to PHY M of Other Node. Switches and Indicators B–11 C Specifications C.1 Specifications Specifications for the DECbridge 500/600 Series of bridges are divided into the following categories and described in Table C-1 through Table C-5: physical, electrical, environmental, acoustic, and cable. The DECbridge 500/600 Series is designed to operate in a satellite equipment room (SER), mounted on a table or desktop, or in a standard 48-centimeter (19-inch) rack. CAUTION ! The air inside a rack can be hotter than the ambient room temperature. Make sure the air entering the bridge does not exceed the maximum inlet temperature of 50° C (122° F). C–1 Table C–1: Physical Specifications Dimension Value Height 17.68 cm (6.96 in) Width 44.20 cm (17.40 in) Depth 36.53 cm (14.38 in) Weight 14.51 kg (32 lbs) Table C–2: Electrical Specifications Parameter Value Voltage 88 to 264 Vac, single-phase, 3-wire Frequency 47 Hz to 63 Hz Input power 390 W (maximum) Heat dissipation 1330 BTU/hr (maximum) Amperage 3.9 at 100 V 1.7 at 240 V Table C–3: Environmental Specifications Parameter Value Operating Environment Temperature (at sea level)* 5° C to 50° C (41° F to 122° F) Relative humidity 10% to 95% (non-condensing) Wet-bulb temperature 32° C (90° F) maximum Altitude Sea level to 2.4 km (8000 ft) Inlet air temperature 50° C (122° F) maximum Nonoperating Environment Temperature -40° C (-40° F) to 66° C (151° F) Relative humidity 10% to 95% (noncondensing) Altitude Sea level to 9.1 km (30,000 ft) *Reduce the maximum operating ambient temperature by 1.8° C per 1000 meters (1.0° F per 1000 ft) for operation at high-altitude sites. C–2 DECbridge 500/600 Series Installation and Upgrade Table C–4: Acoustic Values* Product Sound Power Level LWAd, B Sound Pressure Level LpAm, dBA (bystander positions) DECbridge 500/600 Series Idle/Operate 6.6 Idle/Operate 52 * Declared values per ISO 9296 and ISO 7779. Current values for specific configurations are available from your Digital Services representative. (1 B = 10 dBA) C.1.1 Cable Specifications Table C–5 lists some of the specifications for the power cable, IEEE 802.3/Ethernet cable, and FDDI cable. For more information on cables, refer to the Networks Buyer’s Guide. Table C–5: Cable Specifications Item Power AC power cord length Value U.S. -- 1.83 m (6 ft) Others -- 2.5 m (8.2 ft) IEEE 802.3/Ethernet AUI Interface Transceiver cable length 50 m (164 ft) maximum IEEE 802.3/Ethernet ThinWire Interface ThinWire cable length Specifications 185 m (606 ft) maximum C–3 Table C–5 (Cont): Cable Specifications Item Value Recommended Multimode Fiber Interface Cable Cable length 2 km (6561 ft) maximum Nominal core diameter 62.5 ± 3.0 µm Cladding diameter 125.0 ± 2.0 µm Numerical aperture 0.275 ± 0.015 Modal bandwidth minimum 500 MHz• km at 1300 nm, 160 MHz• km at 850 nm Maximum attenuation rate 1.5 dB/km at 1300 nm, 3.5 dB/km at 850 nm Power budget 11.0 dB at 1300 nm (for FDDI), varies by product at 850 nm Fiber optic connector types Approved MIC plug types A, B, and S; maximum attenuation is 1.0 dB. Alternate Multimode Fiber Interface Cable 100/140 50/125 Cable length 2 km (6561 ft) maximum 2 km (6561 ft) maximum Nominal core diameter 100 µm* ± 4.0 µm 50 µm* ± 3.0 µm Cladding diameter 140 µm* ± 6.0 µm 125 µm* ± 2.0 µm Optical wavelength 1300 nm 1300 nm Numerical aperture 0.290 ± 0.015 0.200 ± 0.015 Modal bandwidth minimum 500 MHz• km @ 1300 nm 500 MHz• km @ 1300 nm Power budget for FDDI 9.0 to 13.0 dB 6.0 to 7.0 dB Maximum distance 1.6 km (.96 mi) 2 km (1.2 mi) (*Power budget contingent on core and cladding tolerances) C–4 DECbridge 500/600 Series Installation and Upgrade Table C–5 (Cont): Cable Specifications Item Value Recommended Single-mode Fiber Interface Cable Cable length 40 km (24.8 miles) maximum Mode field diameter 8.2 µm to 10.5 µm Cladding diameter 125 µm (+ 2.0 µm) Fiber cladding noncircularity 2% maximum Core to cladding concentricity error 1 µm maximum Nominal operating wavelength 1300 nm Fiber cutoff wavelength 1270 nm maximum Zero dispersion wavelength 1300 to 1322 nm Zero dispersion slope 0.095 ps/(nm2km) maximum Optical power attenuation ≤0.40 dB per km at 1310 nm Minimum power budget 22 dB at 1300 nm Minimum required loss 12 dB at 1300 nm Fiber optic connector types Approved FC/PC plug types Recommended Out-of-Band Management Cable For VT100 or VT200 Series Terminals BC22D-xx cables with 25-pin connectors at each end. If you use P/N BC16E-xx cables, use a passive adapter (P/N H8575A) at each end of the cable. For VT300 or VT400 Series Terminals Use the standard six-pin modular jack (MJ6) connector cable P/N BC16E-xx. Use the passive adapter H8575A on the bridge end of the cable. Specifications C–5 D Hardware Upgrade Options You can upgrade the DECbridge 500 unit (as well as other models in the DECbridge 500/600 Series) to another model in the DECbridge 500/600 Series. To upgrade, you add new modules to your existing unit. The three upgrade kits available from Digital provide modules that allow you to upgrade your DECbridge unit in one of the following ways: • Upgrade from a DECbridge 500 (one FDDI connection and one AUI or ThinWire connection) to a DECbridge 610 (one FDDI connection and three AUI connections, no ThinWire connection). The kit used to perform this upgrade (P/N DEFEB-UG) contains: – AP3 module – NI(3) module – AUI testing loopbacks (2) – QC kit including release notes, license, software product description, and Configuring the SNMP Agent manual – Documentation kit (P/N DEFEB-DK) that includes: • Label sheet with new model numbers • Upgrade procedures (includes FDDI registration card) D–1 • Upgrade from a DECbridge 510 (one FDDI connection and one AUI or ThinWire connection) to a DECbridge 520 (two FDDI connections and one AUI or ThinWire connection), upgrade from a DECbridge 600 to a DECbridge 620, and upgrade from a DECbridge 610 to a DECbridge 620. The kit used to perform these upgrades (P/N DEFEB-UP) contains: – FI DAS module (two FDDI connectors) – One multimode testing loopback (two loopbacks required when upgrading from a DECbridge 600 to DECbridge 620) – Documentation kit (P/N DEFEB-DK) that includes: • Label sheet with new model numbers • Upgrade procedures (includes FDDI registration card) • Combine the two upgrade kits (DEFEB-UG and DEFEB-UP) and upgrade from a DECbridge 500 (one FDDI connection and one AUI or ThinWire connection) to a DECbridge 620 (two FDDI connections and three AUI connections, no ThinWire connection). • Upgrade for a DECbridge 500/600 Series unit to a DECbridge 500/600 Series unit with out-of-band management. The kit used to perform this upgrade (P/N DEFEB-UR) contains: – AP3 module with OBM – QC kit including release notes, license, software product description, and Configuring the SNMP Agent manual – Documentation kit (P/N DEFEB-DK) that includes: • Label sheet with new model numbers • Upgrade procedures (includes FDDI registration card) NOTE The AP3 module ships with DECbridge version 1.3 firmware. Ensure that if you reload the AP3 module with firmware at a future date that the version is version 1.3 or higher. D–2 DECbridge 500/600 Series Installation and Upgrade E Related Documents Additional information on the DECbridge and FDDI can be found in the following documents: • Bridge and Extended LAN Reference (Order No. EK-DEBAM-HR) Describes how bridges are used to create extended local area networks (LANs). Includes information on LAN interconnections, overall bridge operation, spanning tree, bridge management, and possible solutions to bridgerelated problems in a network. • Configuring the SNMP Agent for DECconcentrator 500, DECbridge 500/600 Series, and LAN Bridge 200 Products (Order No. AA-PR84A-TE) Describes how to configure the DECconcentrator 500, DECbridge 500/600 Series, and LAN Bridge 200 products as SNMP agents. It also includes troubleshooting information and tests to verify the configuration. • DECbridge 500/600 Series Problem Solving (Order No. EK-DEFEB-PS) Explains how to troubleshoot and service the DECbridge 500/600 Series units. Information includes a product overview, problem-solving methods, removal and replacement procedures for field-replaceable units (FRUs), and configuration guidelines. E–1 • DECconcentrator 500 Installation (Order No. EK-DEFCN-IN) Explains how to install a DECconcentrator 500 wiring concentrator and how to check its installation and operational status. • DECconcentrator 500 Problem Solving (Order No. EK-DEFCN-PS) Explains how to troubleshoot and service the DECconcentrator 500 unit. Information includes a product overview, problem-solving methods, and removal and replacement procedures for field-replaceable units (FRUs). • DECconnect System Satellite Equipment Room Installation Guide (Order No. EK-DECSY-SR) Provides all the steps and procedures for installing the satellite equipment room. • DECconnect System Fiber Optic Planning and Configuration (Order No. EK-DECSY-FP) Provides an overview of Digital’s structured wiring network along with guidelines for planning, configuring, and designing fiber optic subsystems within the network. • DECconnect System Fiber Optic Installation (Order No. EK-DECSY-FI) Contains guidelines for installing fiber optic cables and passive equipment in a DECconnect System fiber optic structured wiring network, along with test procedures for certifying the installation. • DECconnect System Planning and Configuration Guide (Order No. EK-DECSY-CG) Contains planning requirements and guidelines for configuring DECconnect System networks and other networks that use DECconnect System products. E–2 DECbridge 500/600 Series Installation and Upgrade • DECconnect System Facilities Cabling Installation Guide (Order No. EK-DECSY-FC) Provides procedures for properly installing Ethernet coaxial cables, twisted-pair cables, and ThinWire cables within a DECconnect System site. • DECmcc Bridge Access Module Use (Order No. AA-PD1BC-TE) Describes how to use the DECmcc (Digital Management Control Center) Bridge Access Module to manage bridges. • DEFEB DECbridge 500/600 Series (Order No. EK-DEFEB-IP) Contains the illustrated parts breakdown for the DECbridge 500/600 Series units. • FDDI System Level Description (Order No. EK-DFSLD-SD) Describes Digital’s Fiber Distributed Data Interface (FDDI) implementation, how it works, and the role of the individual FDDI components. The manual also discusses Digital’s approach to network management and the facilities provided by network management software and ring-wide configuration issues. • Fiber Distributed Data Interface Network Configuration Guidelines (Order No. EK-DFDDI-CG) Describes the guidelines for connecting devices to an FDDI network. It also includes network configurations and examples. • Networks Buyer’s Guide Describes Digital’s networking products. Contact your local Digital sales office to receive a copy. Related Documents E–3 Index C D Dual homing, B–11 Circuit breaker, B–7 Connecting communications cables, 3–1 AUI, 3–4 FDDI with multimode connectors, 3–7 with single-mode connectors, 3–9 OBM, 3–11 ThinWire, 3–2 to the end of a segment, 3–3 to the middle of a segment, 3–3 Connecting the LCM/OBM cable, 3–11 Connectors AUI, 3–6 FDDI multimode and FDDI singlemode, 3–10 Location of ThinWire, AUI, and FDDI, 3–2 ThinWire, 3–4 Contents, upgrade kit DEFEB-UG, 2–3, 2–4 DEFEB-UP, 2–2 F FDDI connection rules, B–10 FDDI connection rules matrix, B–10 I Installation, Placement Desktop, 1–7 Rackmount, 1–8 Tabletop, 1–7 Installing a new module to upgrade the bridge, 2–1 L Labels, updating, 2–9 LED Indicators, description, B–5 LED states after power up, 3–14 Local Console Management (LCM) Accessing, 4–2 Using, 4–1 Index–1 M S MIB Bridge, 1–2 FDDI, 1–2 Models, DECbridge 500/600 Series, A–2 Modules AP, A–4 description, A–4 FI, A–4 NI, A–4 QM, A–4 Optical bypass connector, B–8 Out–of–Band Management, 4–4 Service, 1–5, 2–5 Shipping package, content, 1–6 Site Preparation, 1–3 Checklist, 1–4 Checklist for upgrades, 2–5 Site Preparation for upgrades, 2–4 SLIP mode, 4–4 Specifications, C–1 Acoustic, C–3 Cable, C–3, C–4, C–5 Electrical, C–2 Environmental, C–2 Physical, C–2 Station management, 1–2 Switches configuration, B–1 setting, 1–7 P T Port addressing, B–7 Power Cord Kits, A–6 Powering Up, 3–13 Preparing for upgrade, 2–5 Problem Solving Basic troubleshooting, 5–1 Symptoms and corrective actions, 5–2 Tools required for upgrade, 2–6 R V Rate limiting, 1–2 Removing a DECbridge Module, 2–6 Replacing a DECbridge module, 2–8 Verifying bridge operation, 3–1 procedure, 3–13 Voltage, automatic setting, 1–7 O Index–2 U Unpacking and inspecting upgrade kits, 2–2 Upgrading, Overview, 2–1 HOW TO ORDER ADDITIONAL DOCUMENTATION DIRECT TELEPHONE ORDERS In Continental USA call 1-800-DIGITAL (1-800–344-4825) In Canada call 800–267–6215 In New Hampshire, Alaska or Hawaii call 603–884–6660 ELECTRONIC ORDERS (U.S. ONLY) Dial 800-dec-demo with any VT100 or VT200 compatible terminal and a 1200 baud modem. If you need assistance, call 1-800-DIGITAL (1-800-344-4825) DIRECT MAIL ORDERS (U.S. and Puerto Rico*) DIGITAL EQUIPMENT CORPORATION P.O. Box CS2008 Nashua, New Hampshire 03061 DIRECT MAIL ORDERS (Canada) DIGITAL EQUIPMENT OF CANADA LTD. 940 Belfast Road Ottawa, Ontario, Canada K1G 4C2 Attn: A&SG Business Manager INTERNATIONAL DIGITAL EQUIPMENT CORPORATION A&SG Business Manager c/o Digital’s local subsidiary or approved distributor Internal orders should be placed through Publishing and Circulation Services (P&CS), Digital Equipment Corporation, 444 Whitney Street, NRO2, Northboro, Massachusetts 01532-2597 *Any prepaid order from Puerto Rico must be placed with the Local Digital Subsidiary: 809–754–7575 DO NOT CUT – FOLD HERE AND TAPE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY LABEL FIRST CLASS PERMIT NO. 33 MAYNARD MASS. POSTAGE WILL BE PAID BY ADDRESSEE Telecommunications and Networks Publications 550 King Street Littleton, MA 01460–1289 DO NOT CUT – FOLD HERE DECbridge 500/600 Series Installation and Upgrade EK-DEFEB-IN. C01 Please return this card. Your comments and suggestions will help us improve the quality and usefulness of our documentation. Did you use the manual as a reference or as a step by step procedure to install the device? _______________________________________________________________________________ Were the instructions easy to follow?_________________________________________ Were the instructions complete?_____________________________________________ Were they in the proper sequence?__________________________________________ Which chapters or sections were most helpful?_________________________________ _________________________________________________________________________________ Did you use the appendices? Which ones?____________________________________ _________________________________________________________________________________ Were the illustrations helpful? ______ All?______ Some?______ Which ones?________ _________________________________________________________________________________ Were some illustrations unnecessary?___________ Which ones?___________________ Do you think the manual needs more illustrations?_________ Please give an example. _________ _________________________________________________________________________________ Thank you. Name Date Title Department Organization City Street State/Country Zip Code TM Printed in U.S.A.
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies