Digital PDFs
Documents
Guest
Register
Log In
EK-LSIFS-SV-PRE
August 1981
610 pages
Original
12MB
view
download
Document:
LSI-11 Systems Service Manual
Order Number:
EK-LSIFS-SV
Revision:
PRE
Pages:
610
Original Filename:
LSI-11_Systems_Service_Manual_Aug81.pdf
OCR Text
lSI-11 Systems Service Manual FOR INTERNAL USE ONLY Preliminary, April 1978 1st Edition, March 1979 1st Edition (Rev), September 1979 2nd Edition, November 1980 3rd Edition, August 1981 Copyright© 1978, 1979,1980,1981 by Digital Equipment Corporation All Rights Reserve.d The material in this manual is for informational purposes and is subject to change without notice. Digital Equipment Corporation assumes no responsibility for any errors which may appear in this manual. Printed in U.S.A. This document was set on DIGITAL's DECset-8000 computerized typesetting system. The following are trademarks of Digital Equipment Corporation: DIGITAL DEC PDP DECUS UNIBUS DECLAB DECsystem-10 DECSYSTEM-20 DIBOL EduSystem VAX VMS 3/82/14 MASS BUS OMNIBUS OS/8 RSTS RSX lAS MINC-11 CONTENTS SYSTEMS CONFIGURATIONS GENERAL CONFIGURATION RULES GENERAL CONFIGURATION RULES ................................................. 3 Backplanes ........................................................................... 3 Configuring Single Backplane Systems ................................ 3 Configuring Multiple Backplane Systems ................................................................................4 Power Supplies ..................................................................... 4 Possible Problems Installing the 70-08612 or BC03Y-XX Cables ............................................. 7 Possible Problems Installing BC05L. ..................................... 7 MEMORY ..........................................................................................8 Memory Refreshing Rules ..................................................... 8 DMA Refresh Configuration .................................................. 8 Configuration Examples .................................... , ................... 9 REFRESH CONFIGURATION PROCEDURE ..................................... 13 PDP-11V03 AND PDP-11T03 SYSTEMS PDP-11 V03 ..................................................................................... 23 Modules Included in the Basic System ............................... 27 PDP-11 V03-A/E Module Utilization .................................... 28 PDP-11 V03-F IH Module Utilization .................................... 30 PDP-11 T03 ......................................................................................31 Modules Included in the Basic System ............................... 34 Module Utilization ...............................................................35 PDP-11T03-L AND PDP-11V03-L SYSTEMS PDP-11 T03-L ..................................................................................37 PDP-11 T03-L Operator Switch Panel ............................................. 38 RLO 1 Disk Drives ............................................................................41 PDP-11 V03-L ..................................................................................42 11 V03-L System (LE, LH, and LJ) ................................................... 46 '11 V03-L Early Systems (LA, LC, and LD) ...................................... .4 7 PDP-11V23 AND PDP-11T23 SYSTEMS PDP-11 V23 SYSTEM ...................................................................... 51 PDP-11 V23 Operator Switch Panel .................................... 52 PDP-11T23 SYSTEM .......................................................................61 PDP-11 T23 Operator Switch PaneL .................................... 62 RLO 1 Disk Drives ................................................ ,............... 64 iii CONTENTS (CONT) COMMERCIAL SYSTEMS 0322 ...............................................................................................69 Modules Included in the Basic System ............................... 73 Optional Modules for Recommended Expansion ........................................................................... 75 0324 ...............................................................................................80 Modules Included in the Basic System ............................... 83 Optional Modules for Recommended Expansion ...........................................................................84 0325 ...............................................................................................90 Modules Included in the Basic System ............................... 92 D333C .............................................................................................93 Compatible Options ............................................................ 94 D335C .............................................................................................95 Modules Included in the Basic System ............................... 95 D336C .............................................................................................97 Modules Included in the Basic System ............................... 98 TELEPHONE COMPANY SYSTEM CC1A PDP-11V03 SYSTEM .......................................................... 101 CC# 1A Diagnostic Check List ..................................................... 102 LABORATORY SYSTEMS PDP-11 L03 .................................................................................... 123 Modules Included in the Basic System .............................................................................. 128 Additional Modules Included in Optional Systems ......................................................... 129 Module Utilization Notes ................................................... 130 PDP-11/03-BASED MINC/DECLAB-11/MINC SYSTEMS MODULAR INSTRUMENTATION COMPUTER (MINC) .................... 135 System-Level Diagnostics ................................................ 141 DECLAB-11/MNC SySTEM .......................................................... 144 System-Level Diagnostics ................................................ 148 Modules in the Basic System ............................................ 149 PDP-11/23-BASED MINC/DECLAB-11 /MINC SYSTEMS MINC ............................................................................................. 155 Systo,n-Level Diagnostics ................................................ 161 Modules in the Basic System ............................................ 162 iv CONTENTS (CONT) DECLAB-11/MNC PDP-11 /23-BASED SySTEM ........................... 166 System-Level Diagnostics ............................................... ,169 Modules Included in the Basic PDP-11/23 System ....................................... 172 CPU/OPTIONS GENERAL MODULE INFORMATION ........................................................ 179 AO 12 ADV 11-A ANALOG-TO-DIGIT AL CONVERTER ................................. 180 A6001 AAV11-A DIGITAL-TO-ANALOG CONVERTER ............................... 185 BA 11-M ..................................................................................................... 190 BA 11-N ......................................................................................................202 DLV11-KA EIA TO 20 MA CONVERTER .................................................... 223 G653/H223 MMV 11-A CORE RAM MEMORy ........................................... 229 H780 POWER SUPPLIES .......................................................................... 232 M7264-XX LSI-11 PROCESSOR MODULES ............................................. 237 M7269 BUS INTERFACE FOR RKV11-D DISK DRIVE CONTROLLER ....................................................................... 250 M7270 LSI-11 /2 PROCESSOR MODEL DESIGNATIONS .......................... 266 M7940 DLV11 SERIAL LINE UNIT ............................................................. 270 M7941 DRV11 PARALLEL LINE UNIT ........................................................ 280 M7942 MRV 11-AA READ-ONLY MEMORy ............................................... 286 M7944 MSV 11-B READ/WRITE MEMORY ................................................ 290 M7946 RXV11 FLOPPY DISK INTERFACE ................................................ 293 M7948 DRV 11-P FOUNDATION MODULE ................................................. 302 M7949 LAV11 PRINTER INTERFACE ........................................................ 315 v CONTENTS (CONT) M7950 DRV 11-B GENERAL PURPOSE DMA INTERFACE ......................... 320 M7951 DUV 11-DA SYNCHRONOUS SERIAL LINE INTERFACE .............. 324 M7952 KWV 11-A PROGRAMMABLE REAL TIME CLOCK ......................... 336 M7954 IBV11-A LSI-11/INSTRUMENT BUS INTERFACE ......................... 346 M7955 MSV 11-C MOS READ/WRITE MEMORY ....................................... 352 M7957 DZV 11 ASYNCHRONOUS MULTIPLEXER ..................................... 357 M8012 BDV11 BUS TERMINATOR, BOOTSTRAP, AND DIAGNOSTIC ROM ............................................................................ 368 M80 13, M80 14 RLV 11 CONTROLLER ...................................................... 384 M8016 .......................................................................................................397 M80 17 DL V 11-E ASYNCHRONOUS SERIAL LINE INTERFACE ............... .402 M80 18 KUV 11-AA WRITABLE CONTROL STORE ..................................... 415 M8021 MRV 11-BA UV PROM-RAM ........................................................... 420 M8027 LPV 11 LP05/LA 180 INTERFACE MODULE ................................... 430 M8028 DL V 11-F ASYNCHRONOUS SERIAL LINE INTERFACE .............. .437 M8029 RXV21 FLOPPY DISK CONTROLLER ........................................... 450 M8043 DL V 11-J SERIAL LINE UNIT ......................................................... .464 M8044/45 MSV11-D, -E MOS READ/WRITE MEMORY ........................... .487 M8047 MXV11-AA/AC MULTIFUNCTION MODULE .................................. 493 M8048 MRV 11-C READ-ONLY MEMORY (ROM) MODULE ..................... 517 M8049 DRV 11-J GENERAL PURPOSE PARALLEL LINE INTERFACE ......................................................................................529 M8186 KDF 11-AX 11/23 MiCROCOMPUTER ........................................... 543 M9400-XX REV 11, TEV 11, AND BCV 1X .................................................... 555 vi CONTENTS (CONT) RK05 .........................................................................................................565 RLO 1/RL02 ...............................................................................................571 RX01 .........................................................................................................575 RX02 ......................................................................................................... 578 APPENDIX A ............................................................................................. 583 APPENDIX B ..............................................................................................601 vii SYSTEMS CONFIGURATIONS GENERAL CONFIGURATION RULES GENERAL CONFIGURATION RULES The rules and considerations discussed in this section apply to all LSI-11 systems. Refer to subsequent sections for requirements peculiar to specific systems. Backplanes LSI-11 systems can be divided into two types: those that use only one backplane, and those that have multiple backplanes. Single backplane systems are viewed as lumped capacitance. Multiple backplane systems are regarded as transmission line systems. The characteristics of the two types differ enough to require separate sets of configuration rules. The rules are given in terms of power consumption, dc bus loading, and ac bus loading. DC loading is a measure of the leakage current a module's bus signal lines draw when high (undriven). One dc load is nominally 105 JlA. AC loading is a measure of the capacitance a module adds to the bus signal lines. One ac load is 9.35 pF. Backplanes also add ac loading to the bus. The power consumption, dc loading, and ac loading is listed for each module in the "CPU/Options" section. Configuring Single Backplane Systems 1. The bus can support up to 20 ac loads before additional termination is required. The processor has on-board termination for one end of the bus, and after 20 ac loads, the other end of the bus must be terminated with 120 Q. 2. A terminated bus can support up to 35 ac loads. 3. The bus can support up to 20 dc loads. 4. The bus signal lines on the backplane can be up to 35.6 cm (14 in) long. The preceding rules apply only to single backplane systems. The bus cannot be extended off the backplane in any way. If it is, the system is considered a multiple backplane system. 3 Configuring Multiple Backplane Systems 1. a. Up to three backplanes may be connected together. b. The signal lines on each backplane can be up to 25.4 cm (10 in) long. 2. Each backplane can have up to 20 ac loads. Unused ac loads from one backplane may not be added to another backplane if the second backplane loading will exceed 20 ac loads. It is desirable to load backplanes equally or with the highest ac loads in the first and second backplanes. 3. Total dc loading of all three backplanes combined can be up to 20 loads. 4. Both ends of the transmission line should be terminated with 120 Q. This means that the first backplane should have impedance of 120 Q, and the last backplane should have a termination of 120 Q. 5. a. The cable connecting the first two backplanes should be at least 1.83 meters (6 ft) long. b. The cable connecting the second backplane to the third backplane must be at least 1.22 m (4 ft) longer or shorter than the cable connecting the first and second backplanes. c. The combined length of the cables should not exceed 4.88 m (16 ft). d. The cables used must have a characteristic impedance of 120 Q. Power Supplies The "CPU / Options" section lists the typical power requirements for each module. For reliable operation, the sum of all typical current requirements should be less than 70 percent of the maximum rated current of the power supply. Refer to the appropriate power supply section for voltage and current ratings. 4 MASTER SUPPLY t--_ _ _ _ _+-_____--1 DCOK M94()()'YE 70-08612-6A (2) BC05L-06 M9401 SLAVE SUPPLY TEV11 M94()().YB MR-0759 A Typical System Configuration Using BA 11-M Boxes Showing Cables Needed for Expansion NOTE Expander boxes are normally shipped with W1 installed. This enables the slave power supply to be powered up and down without being cabled to the master supply. For system applications, however, it Is recommended that W1 be removed. This will ensure that the slave supply does not power up unexpectedly if the cable Is loosened. Business Products systems (0322 and 0324) do not use a POP11/03-J slave console. The two power supplies are connected by a cable (DEC part number (PN) 70-13371-00). No slave board is needed. In a standalone device, such as the RKV11-0 disk drive controller, the W1 jumper must be installed and is not removed if it Is added to a system. 5 LSI-llCPU t-------+-----t 0 0 r-__________+-__________~DCOK GGa MASTER SUPPLY M9400-YE (2) BC05L-06 BCV1B-061 BC03Y-16 ~----~~--~----------~--~ M9401 SLAVE 1 SUPPLY M9400-YD BCV1A-l0--1r-____ L-~ (~2-)-B-CO- 5L- -l-0- ~ ~ __ M9401 SLAVE 2 SUPPLY TEVll M9400-YB ~--------~----------~--~~~--~ NOTE: THE TWO (2) BC05L-XX CABLE LENGTHS BETWEEN THE FIRST AND SECOND BOX SHOULD DIFFER FROM THE BC05L-XX CABLE LENGTHS BETWEEN THE SECOND AND THIRD BOX BY AT LEAST FOUR FEET BECAUSE OF LSI-ll BUS REFLECTIONS. Typical System Configuration Using Three BA 11-M Boxes Showing Cables Needed for Expansion 6 Master /Slave Interface Cables Length 10.2 cm 15 cm 22.9 cm 27.5 cm 35.6 cm 45.7 cm 124 cm 61.0cm 1.83 m 3.05 m DECPN (4 in) (6 in) (9 in) (11 in) (14 in) (18 in) (49 in) (2 ft) (6 ft) (10ft) 70-08612-00 70-08612-0F 70-08612-0K 70-08612-0M 70-08612-1 B 70-08612-1 F 70-08612-4A 70-08612-02 70-08612-6A 70-08612-10 Possible Problems Installing the 70-08612 or BC03Y-XX Cables On a two box system, connect the remote sockets on the master console and the slave console with a 70-08612-XX cable. NOTE Some of the 70-08612 cables have been found with a connector on backwards. If the DCOK LED on the slave box does not come on when the master Is turned on, the cable may be reversed. If RT-11's clock does not update, the 70-08612 cable may be In upside down. The cable should be connected pin 1 to pin 1. The red line should be on the left of both J2 connectors. Possible Problems Installing BC05L Some BC05L-XX cables may have the "This Side Up" stickers on the wrong side of one end. The cables should be connected as follows. • M9400-YE or YO pin AA (J 1) to BC05L-XX pin 1 • BC05L-XX pin 1 to M9401 pin AA (J1) The pin markings on the BC05L cables are on the connector. The cables should be flat when run around the POP-11 /03 cable trays, and not twisted. If the BC05L-XX is plugged in upside down, the bus OCOK line is grounded. The processor will not power up with this condition. Reverse the cables and try again. 7 MEMORY Memory Refresh'ng Rules All dynamic MOS RAM must be refreshed. Neither CORE RAM nor ROM / PROM memories need refreshing. Refreshing is available by three means: processor microcode, Direct Memory Access (DMA), and self-refreshing memory modules. Processor Microcode Refresh - With processor microcode refresh, the processor must be strapped to enable the microcode refresh, and the memory module farthest from the processor on the bus must be configured to reply to refresh cycles. All other memory modules, including memory on the processor board itself, must have memory reply disabled. If only the 4K of RAM on the processor is being used, then that RAM must be strapped to respond to reply. NOTE Only quad-sized processor modules have microcode refresh capabilities. Double-sized processor modules do not. With double-sized processors, either DMA refresh or self-refreshing memory must be used. DMA Refreshing - The REV 11-A or REV 11-C modules may be used to provide DMA memory refreshing. When using the REV11 to refresh memory, the REV 11 refresh capability must be enabled via a strap on the REV 11 board, and the processor microcode refreshing must be disabled. The memory module farthest from the REV 11 should have reply to refresh enabled. If a quad-sized processor module with on-board RAM is used, usually that RAM will be the one strapped to reply to the refresh because it will be the farthest from the REV 11 option. DMA memory refreshing can be done by a customer's own module if that module makes sufficient memory accesses within the required time. Self-Refreshing Memory - Self-refreshing memory does not use the bus to accomplish refreshing; therefore, no memory module need be strapped to reply to a memory refresh cycle. Self-refreshing memory can be combined with nonself-refreshing memory on the same bus; however, when this is done, other refreshing techniques similar to processor microcode or DMA must be used to refresh the conventional memory. If an MSV 11-C is used with a KD 11-F or an MSV 11-8, configure the MSV 11-C for external refresh. DMA Refresh Configuration In systems that use a REV 11-C for refresh and a TEV 11 for bus termination, the REV 11-C should be placed immediately after the memory modules. 8 ORV 11-B or RKV 11-0 modules should follow the REV 11-C in order to be lower in OMA priority. Systems that use a REV 11-A for both refresh and termination must have it in the last slot. No open slots are permitted between the processor and the far-end bus terminator. The OMA and interrupt priority scheme is indicated in the following figure. The arrow indicates decreasing priority. B A C D PROCESSOR 2 3 I I I I 4 ,r I 3 4 I I I TERMINATOR _ MR-0761 Q-Q Backplanes OMA / Interrupt Priority Scheme Configuration Examples If an LSI-11 system must be configured with memories other than the MSV 11-CO, try to use one of the following engineering-approved examples. Ex. 1 M7264-0, -AB, -BB CPU M7944 MSVll-B 4K MEMORY M7940DLV11 SLU M7944 MSVll-B 4K MEMORY M9400-YA REVll-A BOOT/TERMINATOR MR-0798 In this type of configuration, use the M9400 (REV 11) to perform refresh operations. 9 Jumpers would be as follows. M7264 M7944 M9400-YA W4 W9 W10 W4 W2 IN OUT OUT IN (both modules) IN Ex. 2 Disable CPU controlled refresh. Enable reply from CPU memory. Enable CPU reply during refresh. Disable reply during refresh. Enable DMA refresh. M7264-0. -AB. -BB CPU M7955-YD MSV11-CD 16K MEMORY M9400-YA REV11-A BOOT/TERMINATOR M7944 MSV 11-B 4K MEMOR Y MR-0799 In this type of configuration, use REV 11 to control refresh operations. Jumpers would be as follows. M7264 M7955 M9400-YA W4 W9 W10 W7 W6 W2 IN OUT OUT OUT IN IN Ex.3 Disable internal refresh. Disable reply during refresh. M7264-YA. -YB CPU M7955-YD MSV11-CD 16K MEMORY M9400-YA REV11-A BOOT/TERMINATOR M7944 MSV11-B 4K MEMORY MR-0800 In this type of configuration, use REV 11. Jumpers would be as follows. M7264 M7955 M7944 M9400-YA W4 W9 W10 W7 W6 W4 W2 IN IN OUT OUT OUT IN IN Disable CPU refresh. Disable reply from CPU memory. This is a "don't care" (if W9 is in). Disable internal refresh. Enable reply during refresh. Disable reply during refresh. Enable DMA refresh. 10 Ex.4 M7264-0. ·AB. ·BB CPU M7955-YD MSV11·CD 16K MEMORY MA·0801 In this type of configuration, use CPU refresh. Jumpers would be as follows. W4 W9 W10 W7 W6 M7264 M7955 Enable CPU refresh. Enable reply from CPU memory. Disable CPU reply during refresh. Disable internal refresh. Enable reply during refresh. OUT OUT IN OUT OUT Ex.5 M7264·0. ·AB • .aB CPU M8018 KEV11·WA WCS M7t55-YD MSV11-CD 16K MEMORY ........ M7944 MSV11·B 4K MEMORY M9400·YE BUS JUMPER BCV1B M9401 BUS JUMPER M94()()'YC BOOT/TERMINATOR M7952 KWV11-A REAL TIME CLOCK M7950 DRV11·B DMA INTERFACE M7940 DLV11 SLU M94()()'YD BUS JUMPER BCV1A M8028 DLV11·F SLU M9401 BUS JUMPER M7962 RCV' 1-0 ~~~~RFACE M94()()'YB ~~~~~NATOR MA·0802 11 In this type of configuration, use the REV11-C (M9400-YC) to provide refresh. Jumpers would be as follows. M7264 M7955 M7944 M9400-YC W4 W9 W10 W7 W6 W4 W2 IN OUT OUT OUT IN IN IN Disable CPU controlled refresh. Enable reply from CPU memory. Enable CPU reply during refresh. Disable internal refresh. Disable reply during refresh. Disable reply during refresh. Enable DMA refresh. Do not use any configuration with DMA devices between the CPU and a REV 11 performing DMA refresh. The BDV 11 (M80 12) is always at end of the bus. The preferred order of modules in systems is: CPU WCS Memory DMA refresh Real time clock INT fastest 1 slowest DMA fastest 1 slowest Program transfer (ROMs, D / As, etc.) Terminator 12 REFRESH CONFIGURATION PROCEDURE Is this CPU a KD 11-H (M7264-Y A)? YES NO ! ! 2 Go to step 6 Does the system contain an MSV 11-8 (M7944) memory? YES NO ~ • The CPU should have jumpers W10 and W4 installed. • If the system has a REV 11-A (M9400-Y A) or a REV 11-C (M9400-YC), jumper W2 should be removed. • If the system has MSV 11-CD (M7955) memories, jumpers W6 and W7 should be installed in the MSV 11-CD. • If the system has: MSV11-DA M8044-YA MSV11-D8 M8044-Y8 MSV 11-DC M8044-YC or MSV 11-DD M8044-YD there are no refresh configuration requirements for this module. 3 Does the system contain a DMA device other than the REV 11-A (M7900-YA) or a REV11-C (M9400-YC), such as an RKV11-D (M7969) or DRV 11-8 (M7950)? YES NO ~ • Does the system contain a REV 11-A (M9400-Y A) or REV 11-C (M9400-YC)? YES NO ! Is the CPU a DI80L processor (40-pin chip with 2 dies)? 13 NO YES ~ • 1 • You cannot configure this system without a REV11. The CPU (M7264-YA) should control refresh; jumper W4 removed and W10 installed. • The MSV 11-B (M7944) farthest from the CPU will reply; jumper W4 removed. • All other MSV11-B memories should have W4 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-0A M8044-Y A MSV11-0B M8044-YB MSV11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. • The REV11-A (M9400-YA) or REV11-C (M9400-YC) should control refresh; jumper W2 on the M9400 should be installed. • The MSV 11-B (M7944) farthest from the REV 11 should reply to refresh; W4 removed. • All other MSV11-B memories should have W4 installed. • The CPU should not control refresh; jumpers W4 and W10 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-0A M8044-Y A MSV 11-0B M8044-YB 14 4 MSV 11-DC M8044-YC or MSV11-DD M8044-YD l there are no refresh configuration requirements for this module. Does the system contain a REV 11-C (M9400-YC)? NO YES ~ • The REV 11-C (M9400-YC) should control refresh; W2 installed. • The MSV 11-B (M7944) farthest from the REV 11 should reply to refresh; jumper W4 removed. • All other MSV 11-B (M7944) memories should have W4 installed. • There should not be a DMA device placed between the CPU and REV11-C (M9400-YC). • If the system has MSV 11-CD (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-DA M8044-Y A MSV11-DB M8044-YB MSV 11-DC M8044-YC or MSV 11-DD M8044-YD there are no refresh configuration requirements for this module. 5 Is the CPU a DIBOL processor (40-pin chip with 2 dies)? NO YES • • 1 • You cannot configure refresh on a system without a REV11-C. The CPU (M7264-Y A) must control refresh; jumper W 10 installed and W4 removed. 15 • If a REV11-A (M9400-YA) is present, its refresh must be disabled. This means jumper W2 must be removed. • The MSV 11-8 (M7944) farthest from the CPU should respond to refresh; jumper W4 removed. • All other MSV 11-8s (M7944) should have W4 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-0A M8044-Y A MSV11-08 M8044-Y8 MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. FROM 1,5 6 Does the system contain a REV 11-A (M9400- Y A) or REV 11-C (M9400YC)? YES NO ! Is the CPU a 0180L CPU (40-pin chip with 2 dies)? NO YES ~ • You cannot configure this system without a REV11. 1 • Does the system contain an MSV 11-8 (M7944)? YES NO ~ • The CPU (M7264) must control refresh and reply to refresh; jumpers W4 and W10 removed. • The MSV 11-8 (M7944) farthest from the CPU should reply to refresh; jumper W4 removed. • All other MSV 11-88 (M7944) should have jumper W4 installed. 16 • If the system has: MSV11-DA M8044-YA MSV11-DB M8044-YB MSV11-DC M8044-YC or MSV 11-DD M8044-YD there are no refresh configuration requirements for this module. • The CPU must control refresh; jumper W4 removed and W10 installed. • The MSV 11-B (M7944) farthest from the CPU should reply to refresh; jumper 4 removed. • All other system MSV 11-Bs (M7944) should have jumper W4 installed. • If the system has MSV 11-CD (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV11-DA M8044-YA MSV11-DB M8044-YB MSV11-DC M8044-YC or MSV 11-DD M8044-YD there are no refresh configuration requirements for this module. 7 Does the system contain a DMA device other than that of the REV 11-A (M9400-Y A) or a REV 11-C (M9400-YC), such as RKV 11-B (M7969) or DRV11-B (M7950)? YES NO + • YES Does the system contain MSV 11-B (M7944) memory? NO ~ • The REV 11-Y A (M9400-Y A) or REV 11-C (M9400YC) should control refresh; jumper W2 installed. 17 • The CPU should reply to refresh; jumper W4 installed and W10 removed. • All MSV11-B (M7944) memories should have jumper W4 installed. • If the system has MSV 11-CO (M955) memories, jumpers W6 and W7 should be installed. If the system has: MSV 11-0A M8044-Y A MSV 11-0B M8044-YB MSV11-0C M8044-YC or MSV11-00 M8044-YO there are no refresh configuration requirements for this module. • The REV 11-A (M9400-Y A) or' REV 11-C (M9400-YC) should control refresh; jumper W2 installed. • The MSV 11-B (M7944) farthest from the REV 11-A (M9400-Y A) or REV 11-C (M9400-YC) should reply to refresh; jumper W4 removed. • The CPU should not reply to refresh; jumper W4 installed and W10 installed. • All remaining MSV11-B memories should have W4 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV11-0A M8044-YA MSV11-0B M8044-YB MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. 18 8 • Does the system contain a REV 11-C (M9400-YC)? YES NO + • Is the CPU a OIBOL processor (40-pin chip with 2 dies)? NO YES ~ • You cannot configure this system without a REV11. 1 • Does the system contain MSV 11-B (M7944) memory? YES NO •• The CPU (M7264) should control refresh and reply; jumpers W4 and W10 removed. • If the system has a REV11-A (M9400-YA); jumper W2 should be removed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV11-0A M8044-YA MSV 11-0B M8044-YB MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. • The CPU (M7264) should control refresh; jumper W4. • The MSV 11-B (M7944) farthest from the CPU should reply to refresh; jumper W4 removed. • All remaining MSV11-Bs (M7944) should have jumper W4 installed. • If the system has a REV11-A (M9400-YA), jumper W2 should be removed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. 19 • If the system has: MSV 11-0A M8044-Y A MSV 11-0B M8044-YB MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. 9 Does the system have MSV 11-B (M7944) memory? YES NO ~ • The REV11-C (M9400-YC) should control refresh; jumper W2 installed. • The CPU (M7264) should reply to refresh; jumper W 10 removed and W4 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-0A M8044-Y A MSV 11-0B M8044-YB MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. 10 Is the CPU an M7264-EB, -FB, -HB, or -JB? YES NO ~ • The REV 11-C (M9400-YC) should control refresh; jumper W2 installed. • The CPU should reply to refresh; jumper W10 removed and W4 installed. • All MSV11-B (M7944) memories should have jumper W4 installed. 20 • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV11-0A M8044-YA MSV11-0B M8044-YB MSV 11-0C M8044-YC or MSV 11-00 M8044-YO there are no refresh configuration requirements for this module. • The REV 11-C (M9400- YC) should control refresh; jumper W2 installed. • The MSV 11-B (M7944) farthest from the REV 11-C should reply to refresh; jumper W4 removed. • All other MSV 11-Bs (M7944) should have jumper W4 installed. • The CPU should have jumpers W4 and W10 installed. • If the system has MSV 11-CO (M7955) memories, jumpers W6 and W7 should be installed. • If the system has: MSV 11-0A M8044-Y A MSV11-0B M8044-YB MSV 11-0C M8044- YC or MSV11-33 M8044-YO there are no refresh configuration requirements for this module. 21 PDP-11V03 PDP-11V03 AND PDP-11T03 SYSTEMS PDP-11V03 The PDP-11V03 includes a PDP-11 /03 computer, an RX01 dual floppy disk drive, and either a VT52 DECscope or an LA36 DECwriter II. Early models have 8K of memory, while later models have 16K. All models are configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the models, specifications, and components. llV03 CABINET MR-0835 PDP-11 V03-E / H 23 PDP-11V03 IIIIIIIIII:!:::::: 1111111I11:111111111:11111!11 11111111::1111111111 11111111 11111111 1111111111:11111111 1111111::::1111111:::111111111 11111111111111111 11111111 VT52 DECSCOPE llV03 CABINET MA-0836 PDP-11 V03-A / F OJ r®i 0 ~ ° AC LINE (J15V,20A, 230V,lOAI ° MATE-N-LOK CONNECTOR c==:J~c==:J~c::=::J~ -------~ Fr=====0 BN52B-7F FROM VT52 OR BC05F-15 FROM LA36 MR-0837 24 PDP-11V03 LA36 VT52 8K words EA ED AA AD 16K words HA HB HC FA FB FC PDP-11 V03 System Model Designations 8K System Component Model Designations PDP-11 V03 System Model Designations System Requirements AA AD EA ED Input Power (V) 115 230 115 230 Frequency (Hz) 60 50 60 50 PDP-11 /03 Computer EA EB EA EB DE OJ LA36 VT52 AA AB RXV11 (RX01 Floppy with Interface) BA BD BA BD H984 (Cabinet) BA BB BA BB 25 PDP-11V03 16K System Component Model Designations PDP-11V03 System Model Designations System Requirements FA FB FC HA HB HC Input Power (V) 115 230 115 115 230 115 Frequency (Hz) 60 50 50 60 50 50 POP-11 /03 Computer KA KB KA KA KB KA DE OJ OH LA36 VT52 AA AB AC RXV11 (RXO 1 Floppy with Interface) BA BO BC BA BO BC H984 (Cabinet) BA BB BA BA BB BA 115V POWER CONNECTOR 50/60 Hz RECEPTACLE wi I GJ) o @ NEMA #5-15P DEC # 90-08938 5-15R 12·05351 CPU CABINET 50Hz 230 V PLUG ~W PLUG RECEPTACLE -~ ~ ~c::::I NEMA #6·15P DEC # 90-08853 LA36 VT52 CPU CABINET 6·15R 12·11204 LA36 VT52 AMPERAGE TYPICAL MAXIMUM 9.6 10.8 2.0 1.0 4.7 5.3 1.0 0.5 WATTAGE TYPICAL MAXIMUM 800 940 160 118 118 820 960 160 300 300 118 118 BTU/HOUR TYPICAL MAXIMUM 2730 3210 550 1020 400 400 2800 3280 550 1020 400 81.6 Kg 1180 Ib,) 46.3 Kg 11021bs) 20.0 Kg 144lbs) 81.6 Kg 11801bs) 46.3 Kg 11021bB) 20.0 Kg 144 lb.) WEIGHT 400 MR·0838 Specifications 26 PDP-11V03 Modules Included in the Basic System Processor KD11-F (M7264) in PDP-11V03-A/E Resident memory addressed as bank 0 CPU refresh disabled Powers up to 173000 KD11-R (M7264-YA) in PDP-11V03-F/H No resident memory CPU refresh disabled Powers up to 173000 Memory MSV 11-B (M7944) in PDP-11 V03-A I E 4K RAM Refreshed by REV 11-A Addressed as bank 1 MSV 11-CD (M7955-YO) in PDP-11 V03-F I H 16K RAM Internal refresh Addresses start at bank 0 Part of the KD 11-R processor option Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 300 baud in PDP-11V03-E/H (LA36) 9600 baud in PDP-11 V03-A I F (VT52) 20 rnA active transmitter and active receiver One stop bit, eight data bits, no parity Framing error (BREAK) asserts BHAL T 27 PDP-11V03 Floppy Disk Interface RXV 11 (M7946) First device address (disk 0) 177170 First vector 264 Second device address (disk 1) 177150 Second vector 270 Bootstrap I Diagnostic ITermlnator REV11-A (M9400-YA) Bootstrap enabled Diagnostics enabled Refresh enabled in PDP-11 V03-A / E Refresh disabled in PDP-11 V03-F / H 120 g terminator PDP-11V03-A/E Module Utilization A CD 0 ® ® NOTE: C D ® 0 ® CD M7264 PROCESSOR (KD11-F) M7944 (MSVll-B) M7940 (DLVll) M7946 FLOPPY CONTROL (RXV11) M9400-YA (REVll-A) EMPTY EMPTY CIRCLED NUMBERS (DTHROUGH INTERRUPT PRIORITY SEQUENCE. ® REFER TO DMA AND Basic 8K System C A CD @ M7264 PROCESSOR (KDll-F) M7944 4K MEMORY (MSVll-B) M7944 4K MEMORY (MSVll-B) D CD 0) M7940 SERIAL LINE UNIT (DLV11) M7944 4K MEMORY (MSVll-B) ® ® M9400-YA BOOT/TERMINATOR (REVll-A) M7946 FLOPPY DISK CONTROLLER (RXV11) (}) ® NOTE: CIRCLED NUMBERS (j) THROUGH ® REFER TO DMA AND INTERRUPT PRIORITY SEQUENCE. MA·0939 16K System 28 PDP-11V03 CD 0 ® CPu (KDllF) M7946 FLOPPY (RXVll) M7944 4K RAM (MSVll-B) M7940 SLU (DLVll) M7944 4K RAM (MSVll-B) ® M7944 4K RAM (MSVll-B) (j) JUMPER/CABLE TERMINATOR OPTION (BCVl B-XX) M7944 4K RAM (MSVll-B) @ M7944 4K RAM (MSVll-B) M7944 4K RAM (MSVll-B) @ M9400-YA DIAGNOSTIC/BOOT (REVll-A) EXPANDER BOX NOTE: CD CIRCLED NUMBERS THROUGH INTERRUPT PRIORITY SEQUENCE. @ REFER TO DMA AND 11-3720 One-User 28K System CD ® ® CPU (KDllF) + EIS/FIS (KEVll) M7940 SLU (DLV11) M7946 FLOPPY (RXV11) M7940 SLU (DLV11) M7940SLU (DLV11) JUMPE R/CAB LE TERMINATOR OPTION BCVl B-XX ill ® ® M7940SLU (DLV11) (j) M7944 4K RAM (MSVll-B) @ @ M7944 4K RAM (MSVll-B) M7944 4K RAM (MSVll-B) @ @ M7944 4K RAM (MSV11-B) M7944 4K RAM (MSV11-B) @ @ M9400-YA DIAGNOSTIC/BOOT (REV11-A) M79444K RAM (MSVll-B) @ EXPANDER BOX NOTE: CD THROUGH CIRCLED NUMBERS INTERRUPT PRIORITY SEQUENCE. @ REFER TO DMA AND 11- 3719 Four-User 28K System with EIS / FIS 29 PDP-11V03 PDP-11V03-F/H Module Utilization A B (M7264-YA) CD 0 CD ® M7946 FLOPPY DISK CONTROLLER (RXV11) ® 3 + KDll-R PROCESSOR (M7955-YD) ® M7940 SERIAL LINE UNIT (DLVll) SPARE ® NOTE: D C M9400-YA BOOT/TERMLINATOR (REV11-A) 0 CIRCLED NUMBERS (DTHROUGH INTERRUPT PRIORITY SEQUENCE. 4 @ REFER TO DMA AND MR·0840 Basic 16K System A CD 0 ® B D C CD (M7264-YA) + KDll-R PROCESSOR CD (M7955·YD) ® M7955-YD 16K MEMORY (MSV11-CD) ~ / / / / / / / / / / / / /~ / / / / ;ij1M7946 FLOPPY DISK CONTROLLER (RXV11)0 4 ) BCV1 B-XX JUMPER/CABLE TERMINATOR OPTION ~ ( v////////////////////.;: M7940 SERIAL LINE UNIT (DLV11) @ M9400-YA BOOT/TERMINATOR (REV11-A) SPARE @ SPARE @ M7940 SERIAL LINE UNIT (DLV11) NOTE: CD SPARE SPARE @ @ @ @ 4 @ CIRCLED NUMBERS THROUGH REFER TO DMA AND INTERRUPT PRIORITY SEQUENCE. Two-User 28K System 30 MA-591B PDP-11T03 PDP-11T03 The PDP-11T03 comprises a PDP-11 /03 computer, two RK05 disk drives, and an LA36 DECwriter II. The basic system includes 16K of memory. The system may be ordered without the LA36. A" models are configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the models, specifications, and components. SYSTEM CONTROL SWITCHES RK05J DISK DRIVE (REMOVABLE DISK CARTRIDGES) RK05F DISK DRIVE (FIXED DISK) B61 POWER CONTROLLER 31 LA36 DECwriter" TERMINAL PDP-11T03 AC LINE SWITCH AND FUSE TERMINAL CONNECTOR MR-0140 32 PDP-11T03 System Component Model Designations PDP-11 T03 System Model Designation System Requirements AA AB AC AD BA BB BC BD Input Power (V) 115 230 115 230 115 230 115 230 Frequency (Hz) 60 60 50 50 60 60 50 50 PDP-11/03 Computer KA KB KA KB KA KB KA KB LA36 DE DF DH DJ RKV11-D A B A B A B A B RK05 AA AB BA BB AA AB BA BB Specifications LA36 CPU CABINET PLUG POWER CONNECTORS 115V 50/60 HZ RECEPTACLE @o o@ NEMA # L5.3OP DEC # 12·11193 L5·30R 12·11194 @o o@ y 230 V 50/60 HZ ~ IJ y NEMA # L6-2OP DEC # 12·11192 L620R 1211191 PLUG RECEPTACLE wll © @Uw NEMA #5·15P DEC #90-08938 5-15R 12·05351 Cd -- ~ D c:::::Jt::::I NEMA # 6-15P DEC # 90-08853 6-15R 12·11204 WATTS 860 300 BTU/HOUR 2940 1020 WEIGHT 294.8 KG 46.4 (850 LBSt (102 LBst MR·0764 33 PDP-11T03 Modules Included in the Basic System Processor KD11-S (M7264-YA) No resident memory KEV 11 EIS / FIS option included CPU refresh disabled Powers up to 173000 Memory MSV11-CD (M7955-YD) 16K RAM Internal refresh Addresses start at bank 0 The memory is part of the KD 11-R processor option Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 300 baud 20 rnA active transmitter and active receiver One stop bit, eight data bits, no parity Framing error (BREAK) asserts BHAL T Disk Drive Interface RKV 11-D (M7269 plus box) First device address (drive 0/ 1) 177170 First vector 264 Second device address (drive 2) 177150 Second vector 270 34 PDP-11T03 Bootstrap I Diagnostic ITerminator REV11-A (M9400-YA) Bootstrap enabled Diagnostics enabled Refresh disabled 120 Q terminator Module Utilization I A D M7264-YA CPU (KD11-R) AND ARITHMETIC OPTION (KEV11) 0 KD11-S PROCESSOR ® M7955-YD 16K MEMORY (MSV11-CD) 0 CD M7940SERIAL LINE UNIT (DLV11) M7269 BUS INTERFACE CD 0 SPARE M9400-YA BOOT/TERMINATOR (REV11-A) 0 CD NOTE: CIRCLED NUMBERS THROUGH INTERRUPT PRIORITY SEQUENCE· ® REFER TO DMA AND 0 Basic 16K System M9400-YE A M7940 SERIAL LINE UNIT (DLV11) M9400-YA BOOT/TERMINATOR M7940 SERIAL LINE UNIT (DLV11) (REV11-A) SPARE SPARE SPARE SPARE M9401 CD THROUGH NOTE: CIRCLED NUMBERS INTERRUPT PRIORITY SEQUENCE. @ REFER TO DMA AND Two-User Expanded 28K System 35 @ @ @ @ 2 3 4 PDP-11T03-L PDP-11T03-L AND PDP-11V03-L SYSTEMS PDP-11 T03-L The PDP-11T03-L is a general purpose computer system that can be used for developing and executing programs in a variety of applications. RT-11 software provides a single user foreground and background system; it can support a real time application job execution in the foreground and an interactive or batch program development job in the background. RT-11 is also available for a single job configuration. The PDP-11 T03-L system consists of the following equipment. PDP-11 /03-LC (115 Vac) or PDP-11 /03-LD (230 Vac) minicomputer with: KD 1 '1-H microcomputer plus 16K words (32K bytes) of MOS memory (MSV11-CD) BA 11-NC (-ND) box with an H9273 backplane and an H786 power supply BDV11-AA bootstrap/diagnostic/terminator and ROM option. MSV 11-CD configured as an additional 12K words (24K bytes) of MOS memory KEV 11 Extended Instruction Set / Floating Point Instruction Set (EIS / FIS) RLV11 disk controller RLO 1 five-megabyte dual disk drive units and cartridges DL V 11-F serial line unit H9612-AC cabinet Power controller 871-A 871-B 871-C 110 V 220V 110 V 12 A 8A 16 A 50/60 Hz 50/60 Hz 50/60 Hz 37 PDP-11T03-L In addition to the preceding items, one RT -11 system software kit and one RLOP + diagnostic kit are shipped with the system. The following optional terminals are available for the system. LA36 OECwriter VT52 OECscope (with or without copier) VT100 Alphanumeric Video Terminal PDP-11T03-L Operator Switch Panel Communication between the user and the processor is provided by switches on the front panel of the POP-11 /03-L or by the terminal connected to the system. The operator switch panel contains three switches: AUX ON/OFF, HALT, and RESTART. The functions and positions of the switches are as follows. Switch Position Function AUX ON / OFF OFF As configured at the factory, this switch, when turned off, removes ac power to the system. ON As configured at the factory, it turns on ac power. If the automatic bootstrap is selected and the HALT switch is up, the system boots. Up (Enable) This enables the processor to run. Down (HALT) This halts the processor, which responds to console OOT commands. Refer to the Microcomputer Processor Handbook, EB18451-20, for OOT instructions. RESTART (Momentary Switch) When this switch is activated, the processor carries out a power-up sequence. As shipped, the system presents the bootstrap dialog as: HALT RESTART 28 START? The HALT switch must be up (enable). 38 PDP-11T03-L The switch panel also contains two indicators that provide the following information. LED Condition Indication PWR OK ON This LED lights when the proper dc output voltages are being generated by the H786 power supply. RUN ON This LED lights when the processor is in the run state. It goes out when the processor is not executing instructions. ----.:::~~c:::-CARTRIDGE ACCESS DOOR _-+-11-- RLOI DISK DRIVE 11/03-L MICROCOMPUTER --+-1t-- RLOI DISK DRIVE STABI LlZE R FOOT PDP-11 T03-L Computer System 39 PDP-11T03-L CIRCUIT BREAKER FROM DLVll FROM DRIVE 0 BOTTOM DRIVE 0 PWR CORD BC06R FROM RLVll FROM PWR CONTROL (Jl) TO DRIVE 0 TOP TOP BOTTOM (TERMINATOR) DRIVE 1 PWR CORD C-:7'7----~f.i!...-LCI RCUIT BREAKER EXPANDER BOX (IF REQUIRED) TO J2 ON 11/03-L FRONT PANEL MONITOR LAMP FROM RLOl DRIVE 1 AC CI RCU I T -+--tH--::=!I~loH1 BREAKER PDP-11T03-L (Rear Panel Removed) 40 PDP-11T03-L LED INDICATORS SPARE PWR OK RUN RESTART CONTROL SWITCHES HALT ON AUX OFF Front Panel Switches and Indicators RL01 Disk Drives The RLO 1 disk drive is a random access mass storage device with a removable, top-loading disk cartridge. Access to the disk is provided by a lift-up cover. The RL01 has four indicators on its front panel. Their functions are as follows. Indicator Function LOAD (Push Button) Lights to indicate that the spindle has stopped and a cartridge may be loaded. UNIT SELECT (READY) Lights to indicate that drive 0 or 1 is ready to read, write, or receive controller commands. FAULT Lights to indicate that a drive error condition exists. WRITE PROT (Push Button) Lights to indicate that the cartridge currently mounted is protected from having data written on it. 41 PDP-11V03-L LOAD UNIT SE[.ECT (READY) MR·1860 RL01 Disk Drive (Front View) PDP-11V03-L The PDP-11 V03-L includes a PDP-11 /03-L computer and an RX02 dual floppy disk system. The system also has 64K bytes or 32K words of RAM memory. Earlier systems have 32K bytes or 16K words of RAM memory that is expandable to 32K words. The system has the following optional terminals. LA36 DECwriter VT52 DECscope VT 100 DECscope The figures and tables that follow describe the models, specifications, and components. 42 PDP-11V03-L lolGITAL IIV03-L J Idigital PDP III03-q [(~ ©J©J~) )) Idigital RX021 I I w ill PDP-11 V03-L System 43 PDP-11V03-L POWER SUPPLY BA11-N BACKPLANE AND MODULES ---+--++-i-PDP 11/03-L ....--+-+--+-t-R X02 _-++-+--+~::~~SION OF REQUIRED) POWER CORD PDP-11 V03-L System (Backpanel Removed) 44 PDP-11V03-L LOCAL POWER POWER CONTROLLER RECEPTACLE PLUG 871·A 871·A 115V 15A 5O/60HZ @ o ©•• I} NEMA#5·15P DEC # 90·08938 5·20R 12·12265 871-B 871·B 230V 10A 50/60HZ 8-- Cd c:::I c:::I NEMA#6·15P DEC # 90·08853 6·15R 12·11204·01 871-C 871·C 115V 20A 50/60HZ © -. HUBBELL # 5366·C DEC # 12·15183 @ o I? NEMA#5·20R 12·12265 MA·24011 Power Connectors 45 PDP-11V03-L 16K System Components System Requirements LA Models LC LD Input Power (V) 115 115 230 Frequency (Hz) 60 50 50 POP-11 /03-L Computer -LC -LC -LO RX02 Floppy Disk -BA -BC -BO Power Controller 871-A 871-A 871-B 32K System Components System Requirements LE Models LH LJ Input Power (V) 115 115 230 Frequency (Hz) 60 50 50 POP-11 /03-L Computer -LK -LK -LL RX02 FloppyDisk -BA -BC -BO Power Controller 871-A 871-A 871-B 11V03-L System (LE, LH, and LJ) The POP-11 V03-L system consists of the following equipment. A POP-11 /03LK-LL microcomputer consisting of: K011-HA (M7270) a microcomputer board MSV 11-00 (M80440) a 32K word RAM BA 11-N a mounting box with an H9273 backplane and an H786 power supply BOV11-A a bootstrap / diagnostic / terminator with expandable ROM space for the user (M8012-YA). 46 PDP-11V03-L KEV11 A chip, mounted on the KD 11-H microcomputer, that provides the system with the Extended Instruction Set (EIS) and Floating Point Instruction Set (FIS) features. RXV21 The RX02 floppy disk controller module (M8029) interfaces the RX02 disk to the LSI-11 bus. DLV11-J The asynchronous four-channel line interface module (M8043) interfaces the terminal to the LSI-11 bus. RX02 The dual floppy disk system. H9610 The cabinet in which the hardware is mounted. 871 The primary power controller for the 11 V03-L system. Floppy Disks The operational and diagnostic software programs are stored on floppy disks and are shipped as part of the system. 11V03-L Early Systems (LA, LC, and LD) The PDP-11 V03-L system consists of the following equipment. A PDP-11 /03LC-LD microcomputer consisting of: KD11-R a KD11-H (M7264-YC) microcomputer board and a MSV 11-CD (M7955) 16K MOS memory board SA 11-N a mounting box with an H9273 backplane and an H786 power supply SDV11-A a bootstrap/diagnostic/terminator with expandable ROM space for the user (M8012-YA). KEV 11 A chip mounted on the KD 11-H microcomputer that provides the system with the Extended Instruction Set (EIS) and Floating Point Instruction Set (FIS) features. RXV21 The RX02 floppy disk controller module (M8029) interfaces the RX02 disk to the LSI-11 bus. DL V 11-F The asynchronous line interface module (M8028) interfaces the terminal to the LSI-11 bus. RX02 The dual floppy disk system. 47 PDP-11V03-L H9610 The cabinet in which the hardware is mounted. 871 The primary power controller for the 11 V03-L system. Floppy Disks The operational and diagnostic software programs are stored on floppy disks and are shipped as part of the system. C/O BUS (FOR INTERCONNECTING) Q-BUS A KDll-R { MICRO COMPUTER C B CD KDll-H(M7264-YC) (3) MSVll-CD (M7955) 0 CD RXV21 (M8029) 3 0) DLVll-F (M80281 4 CD 5 ® 6 CD ® ® 8 9 BDVll-AA (M8012-YA) ® NOTE: CIRCLED NUMBERS CDTHROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. MR-2022 PDP-11 V03-LA, -LC, and -LD Configuration 48 PDP-11V03-L Q-BUS A C/D BUS (FOR INTERCONNECTING) C B D <D M7270 CPU (KDll-HA) AND OPTION (KEVll) EMPTY 0 M8044D 32K MEMORY (MSVll-DD) EMPTY 2 ® M8029 RX021NTERFACE (RXV21) EMPTY 3 0M8043 SERIAL LINE UNIT (DLV11-J) EMPTY 4 ® OPTION 5 EMPTY 5 ® OPTION 6 EMPTY 6 (2) OPTION 7 EMPTY 7 ® OPTION 8 EMPTY 8 ® M8012-YA BOOTSTRAP/DIAGNOSTIC/TERMINATOR (BDVll-AA) 9 @ NOTE: CIRCLED NUMBERS (DTHROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL LEVELS. MR-2407 PDP-11 V03-LE, -LH, and -LJ Backplane Configuration 49 PDP-11 V03-L Q-BUS C/D BUS (FOR INTERCONNECTING) (1) KD 11-HA (M7270) EMPTY ® ® 0 MSV11-DD (MB044D) EMPTY RXV21 (MB029) EMPTY DLV11-J (MB043) EMPTY ® ® CD ® M9400-YE OPTION 5 OPTION 6 OPTION 7 OPTION 8 LLLLLLLL .- LLLA ~ L..:: EMPTY ~ BCV1 B-XX JUMPER/CABLE BC05L-XX TERMINATOR OPTION M9401 --...V EMPTY @ OPTION 11 @ @ OPTION 12 @ @ OPTION 14 OPTION 15 @ OPTION 16 @ @ OPTION 17 OPTION 13 BDV11-AA DIAGNOSTIC/BOOTSTRAP/TERMINATOR CD @ THROUGH REFER TO THE DMA PRIORITY NOTE: CIRCLED NUMBERS SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. MR-2408 PDP-11 V03-LE, -LH, and -LJ System Expansion 50 PDP-11V23 PDP-11V23 AND PDP-11T23 SYSTEMS PDP-11V23 SYSTEM The PDP-11 V23 is a general purpose computer system that can be used for developing and executing programs for a variety of applications. Optional hardware and software is available for applications such as highlevel language program development support, foreground / background real time support, multiprogramming, and the ability to monitor and control equipment. The PDP-11 V23 can support a real time application job execution in the foreground and an interactive or batch program development in the background. RT-11 is also available for a single job configuration. The PDP11 V23 system contains the following equipment. A PDP-11 /23 minicomputer with: KDF 11-AA microprocessor module (M8186) contained on a doubleheight module MSV 11-DD (M8044D) two double-height modules with 128K bytes of MOS RAM (on two modules) expandable to 256K bytes (four modules) BA 11-N mounting box with an H9273 backplane, an H786 power supply, and H403-A ac input box and a front bezel panel (54-12985) BDV 11-AA bootstrap / diagnostic / terminator with ROM option (M80 12-VA). expandable user DL V 11-J Asynchronous four-channel serial line interface unit (M8043). (Must be CS revision "E" or higher.) RXV21 The RX02 floppy disk controller module (M8029) interfaces the RX02 to the LSI-11 bus. (Must be at CS revision "E 1" or higher.) RX02 The dual drive floppy disk system. H9610 Free-standing 76.8 cm (30 in) high cabinet. 51 PDP-11V23 Power controller 871-A • 871-8 871-C· 120Vac 12A 230 Vac 8A 120 Vac 20 A 50/60 Hz (early 120 Vac systems) 50/60 Hz 50/60 Hz (later 120 Vac systems) In addition to the preceding configuration, the following items are shipped with the PDP-11 V23 system. RT -11 system software package DYDP + diagnostic kit Floppy disk set. Disks contain the RT -11 operating system software and DYDP diagnostic programs. Option terminals available for the system configuration include the following. LA38 DECwriter IV LA 120 DECwriter III VT100 Alphanumeric Video Terminal PDP-11 V23 Operator Switch Panel Three control switches on the front of the PDP-11 123 provide a communication link between the operator and the microcomputer system. The switches labeled AUX ONIOFF, HALT, and RESTART provide power, stop, and bootstrap control for the PDP-11 123. The switch functions are defined as follows. Switch Position Function AUX ON I OFF OFF In the normal factory configuration, turning this switch off removes ac power from the system. ON In the normal factory configuration, turning this switch on applies ac power to the system. If the HALT switch is up, the system is automatically booted. • Systems built before April 1980 use 871-A power controllers. Systems built after April 1980 use 871-C power controllers. 52 PDP-11V23 HALT RESTART Up (Enable) This switch enables the processor to run. Down (HALT) The HALT switch, when down, halts the processor, which responds to console OOT commands. Refer to the Microcomputer Processor Handbook, EB18451-20, for OOT instructions. RESTART (Momentary Switch) When this switch is activated, and when the HALT switch is up, the processor carries out a power-up sequence and displays the bootstrap dialog as: 28* START? HMHH3.tJ • The BOV 11 software automatically sizes the available memory in the system and prints the number 28. The 28 is the present limit for the BOV 11 ROM software. The actual available memory maximum is 124K words. The user should be aware of the actual memory and not depend on the printout. The memory-sizing software will be updated and eventually print out the actual memory size up to the addressing limit of the CPU. 53 PDP-11V23 C A BAll-N BOX D 1 KDFll-AA (M8186) EMPTY 2) MSVll-DD (M8044D) EMPTY 3 MSVll-DD (M8044D) EMPTY 4 RXV21 (M8029) • EMPTY 5 DLVll-J (M8043)** 4 5 6 7 7 8 M9400-YE -a 8 OPTION ///L//L/LJ///LL~ EMPTY 9 i4--- BCVl B-XX JUMPER/CABLE BC05L-XX TERMINATOR OPTION M9401 _17/ ~ 11 BAll-N EXPANSION BOX 12 OPTION 3 13 OPTION 4 14 OPTION 15 OPTION 16 OPTION OPTION 17 M9400-YD -~ / /////////////~ BA11-M BOX 'NOTE: •• NOTE: -~ - 9 j4-BCV1A-XX JUMPER/CABLE TERMINATOR OPTION BC05L-XX M9401 EMPTY OPTION ////// / ~ 20 1(22 21 2 103 24 3 25 4 26 BDV11-AA (M8012-YA) MUST BE AT CS REVISION 'El' OR HIGHER MUST BE AT CS REVISION 'E' OR HIGHER @ NOTE: CIRCLED NUMBERS G)THROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS PDP-11 V23 System Expansion Example 54 PDP-11V23 The PDP-11 /23 front switch panel also contains two indicators that provide the following information. LED Function PWR OK Illuminated when the proper dc output voltages are being generated by the microcomputer system. RUN Illuminated when the processor is operating; turned off when the processor is not executing instructions. The following is an expanded PDP-11 V23 configuration example using both the BA 11-N and BA 11-M boxes. LED INDICATORS SPARE RESTART PWR OK RUN CONTROL SWITCHES HALT ON AUX OFF MR 4891 Front Panel Switches and Indicators 55 PDP-11V23 POWER SUPPLY BA11-N BACKPLANE AND MODULES -----t---+l-t-PDP 11/23 ----+-r-+~~RX02 EXPANSION --++--t--t- SPACE (I F REQUI RED) POWER CORD PDP-11 V23 with Backpanel Removed 56 PDP-11V23 CIRCUIT BREAKER REMOTE POWER SWITCH A.C. POWER MONITOR ~----POWERCORD Power Controller (Rear View) " 115 VAC/230 VAC SWITCH POWER CONNECTOR FUSE PDP-11 /23 Microcomputer (Rear View) 57 REMOTE POWER CONNECTORS PDP-11V23 C/D BUS (FOR INTERCONNECTING) Q-BUS A C B D CD KDFll-AA (M8l86) (3) MSVll-DD (M8044D) 2 ® MSVll-DD (M8044D) 3 0 ® RXV2l (M8029) * 4 DLV11-J (M8043) ** 5 ® 6 0) 7 1------ ® ® 8 BDVll-AA (M8012-YA) *NOTE: MUST BE AT CS REVISION 'El' OR HIGHER **NOTE: MUST BE AT CS REVISION 'E' OR HIGHER 9 ® NOTE: CIRCLED NUMBERS G)THROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. MR4873 PDP-11 V23 Module Configuration 58 PDP-11V23 A BAll-N BOX J B C 1) KDFll-AA (M8186) D 2) MSVll-DD (M8044D) 2 3 MSVll-DD (M8044D) 3 4 MSVll-DD (M8044D) 4 5 MSVll-DD (M8044D) 5 6 RXV21 (M8029) * 6 7 DRVll-J (M8049) 7 DLVll-J (M8043) ** 8 1(8 M9400-YD --.~////////////////~ :.-- BCV1A-XX JUMPER CABLE TERMINATOR OPTION BC05L-XX M9401 BAll-M BOX --+~/////////////// ~ --- 9 11 13 (12 2 14 (15 3 16) 4 BDVll-AA (M8012-YA) 17 *NOTE: MUST BE AT CS REVISION 'E l' OR HIGHER **NOTE: MUST BE AT CS REVISION 'E' OR HIGHER CD @ NOTE: CIRCLED NUMBERS THROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. MR-4875 PDP-11 V23 Expansion Example 59 PDP-11V23 POWER CONTROLLER LOCAL POWER RECEPTACLE PLUG 87l-A l15V l5A 50/60HZ ,, © 87l-A @ o [> NEMA # 5-l5P DEC # 90-08938 5-20R 12-12265 871-B 871-B 230V lOA 50/60HZ -~ == ~ NEMA # 6-l5P DEC # 90-08853 6-15R 12-11204-01 871-C 871-C 115V 20A 50/60HZ -, © HUBBELL # 5366-C DEC # 12-15183 @ o [? NEMA # 5-20R 12-12265 MR-2405 System Requirements AA Model AC Input Power (V) Frequency Current PDP-11 V23 Computer RX02 Floppy Disk Power Controller 120 60 12 AA BA 871-A • or 871-C 120 50 12 AA BC 871-A • or 871-C AD 240 50 8 AB BD 871-B • Systems built before April 1980 use 871-A power controllers. Systems after April 1980 use 871-C power controllers. 60 PDP-11T23 PDP-11T23 SYSTEM The PDP-11 T23 is a general purpose computer system that can be used for developing and executing programs for a variety of applications. Optional hardware and software are available for applications such as highlevel language program development, foreground Ibackground real time support, multiprogramming, and equipment monitoring and control capability. PDP-11 T23 can support a single user with a foreground I background system. It can support a real time application job execution in the foreground and an interactive or batch program development in the background. RT -11 is also available for a single job configuration. The PDP-11T23 system contains the following equipment. A PDP-11 123 minicomputer with: KDF 11-AA microprocessor module (M8186) contained on a doubleheight module MSV 11-DD (M8044D) two double-height modules with 128K bytes of MOS RAM (on two modules) expandable to 256K bytes (four modules) BA 11-N mounting box with an H9273 backplane, an H786 power supply, and H403-A ac input box and a front bezel panel BDV 11-AA bootstrap I diagnostic I terminator with ROM option (M80 12-Y A). expandable user DL V 11-J Asynchronous four-channel serial line interface unit (M8043). (Must be at CS revision "E" or higher.) RLO 1 Five-megabyte dual disk drive units and cartridges H9612 105 cm (42 in) high cabinet Power controller 871-A • 871-B 871-C· 120 Vac 230 Vac 120 Vac 12 A 8A 16 A 50/60 Hz 50/60 Hz 50/60 Hz In addition to the preceding configuration, the following items are shipped with the system. 1 RT -11 or RSX -11 M system software kit 1 DLDP + diagnostic kit • Systems built before April 1980 use 871-A power controllers. Systems built after April 1980 use 871-C power controllers. 61 PDP-11T23 Optional terminals available for the system include the following. LA38 DECwriter IV LA 120 DECwriter III VT100 Alphanumeric Video Terminal PDP-11 T23 Operator Switch Panel Three control switches on the front of the PDP-11 T23 provide a communication link between the operator and the microcomputer system. The switches labeled AUX ON/OFF, HALT, and RESTART provide power, stop, and bootstrap control, respectively. The switch functions are defined as follows. Switch Position Function AUX ON / OFF OFF In the normal factory configuration, this removes ac power from the system. ON In the normal factory configuration, this applies ac power to the system. If the HALT switch is up, the system is automatically booted. Up (Enable) This enables the processor to run. Down (HALT) This halts the processor, which will respond to console odt commands. Refer to the Microcomputer Processor Handbook, EB-18451-20, for ODT instructions. RESTART (Momentary Switch) When this switch is activated, and when the HALT switch is up, the processor carries out a power-up sequence and displays the bootstrap dialog as: HALT RESTART 28* START? *The BDV11 software automatically sizes the available memory in the system and prints the number 28. The 28 is the present limit for the software. The actual available memory maximum is 124K words. The user should be aware of the actual memory and not depend on the printout. The memorysizing software will be updated and eventually print out the actual memory size up to the addressing limit of the CPU. 62 PDP-11T23 Ilooooij I I II digital 11T23 11 I I 1 digital PDP 11/231 II (c:) ~~g ) II .[1000011 I I I I 0 1 o ----- ---- PDP-11 T23 Computer System 63 I PDP-11T23 LED INDICATORS SPARE PWR OK RUN RESTART CONTROL SWITCHES HALT ON AUX OFF MR-4B91 Front Panel Switches and Indicators The PDP-11 T23 front switch panel also contains two indicators that provide the following information. LED Function PWR OK Illuminated when the proper dc output voltages are being generated by the microcomputer system. RUN Illuminated when the processor is operating; turned off when the processor is not executing instructions. RLO 1 Disk Drives The RLO 1 disk drive is a random access mass storage device with a removable, top-loading disk cartridge. Access to the disk is provided by a lift-up cover. The RL01 has four indicators on its front panel. Their functions are as follows. Indicator Function LOAD (Push Button) Lights to indicate that the spindle has stopped and a cartridge may be loaded. UNIT SELECT (READY) Lights to indicate that drive 0 or 1 is ready to read, write, or receive controller commands. 64 PDP-11T23 FAULT Lights to indicate that a drive error condition exists. WRITE PROT (Push Button) Lights to indicate that the cartridge currently mounted is protected from having data written on it. The following is an example of the PDP-11 T23 microcomputer with an expanded configuration using both the BA 11-N and BA 11-M boxes. System Requiremp-nts AA Input Power (V) Frequency Current PDP-11 T23 Computer RL01 Disk Power Controller 120 50/60 12 A AA AK 871-A • or 871-C Models AB AC 240 50/60 8A AB AK 871-B 120 50/60 16 A AA AK 871-COO .. Systems built before April 1980 use 871-A power controllers. Systems built after April 1980 use 871-C power controllers. LOAD UNIT SELECT (READY) FAULT RLO 1 Disk Drive (Front View) 65 PDP-11T23 FROM DLV11-J FROM DRIVE 0 BOTTOM DRIVE 0 PWR CORD BC06R FROM RLV11 FROM PWR CONTROL (J1) TO DRIVE 0 TOP 11/23 PWR CORD TOP BOTTOM (TERMINATOR) DRIVE 1 PWR CORD ~-~::7-------k..iJ--.JLCI RCUIT BREAKER EXPANSION BOX (IF REQUIRED) TO J2 ON 11/23 FRONT PANEL MONITOR LAMP FROM RL01 DRIVE 1 AC CIRCUIT~-+I-t-"..~~ BREAKER PDP-11T23 (Rear Panel Removed) 66 PDP-11T23 115 VAC/230 VAC SWITCH POWER CONNECTOR CIRCUIT BREAKER PDP-11 /23 Microcomputer (Rear View) C/D BUS (FOR INTERCONNECTING) Q-BUS A C B D CD KDFll-AA (M8186) @ 2 MSVll-DD (M8044D) CD MSVll-DD (M8044D) RLVll (M8013) DISK CONTROL 0 ® CD 3 4 RLVll (M8014) BUS CONTROL 5 DLV11-J (M8043) * 6 CD ® @ *NOTE: 7 8 9 BDVll-~A (M8012-YA) MUST BE AT CS REVISION 'E' OR HIGHER NOTE: CI RCLED NUMBERS (i) THROUGH (g)'REFER TO THE DMA PRIORITY SEQUENCE AND TH'E"'PHYSICAL IN'fERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. MR-4877 Typical PDP-11 T23 Module Configuration 67 PDP-11T23 A CD <V @ @ BA11-N BOX B C EMPTY MSV11-DD (MB044D) EMPTY MSV11-DD (MB044D) EMPTY DLV11-J (MB043)' EMPTY 6 EMPTY B 9 OPTION ® OPTION M9400-YE _~LL/L L ~ /1////// r-- BC05L-XX BCV-XX JUMPER/CABLE TERMINATOR OPTION OPTION -~ ~///////////// ~ @ OPTIONS @ r- -@ 14 OPTIONS M9400-YD _ r - - - @ OPTION --- BC05L-XX -BCV1A-XX M9401 _ r - - " ~ @= @- 3 4 JUMPE R/CAB LE TERMINATOR OPTI ON EMPTY @ @) BA11-N BOX 4 RLV11 (MB014) BUS CONTROL (i) M9401 3 RLV11 (MB013) DISK CONTROL ® ® BA11-M BOX D KDF11-AA (MB1B6) OPTION ® OPTION -® @ ®-- =-® 4 OPTION 5 OPTION 6 OPTION 7 OPTION B BDV11-AA (MB012-YA) 9 ® "NOTE: MUST BE AT CS REVISION 'E' OR HIGHER CD ® NOTE: CI RCLED NUMBERS THROUGH REFER TO THE DMA PRIORITY SEQUENCE AND THE PHYSICAL INTERRUPT PRIORITY ON EACH OF THE INDIVIDUAL INTERRUPT LEVELS. PDP-11 T23 Module Expansion Example 68 0322 COMMERCIAL SYSTEMS 0322 The standard Datasystem 322 includes the following. • Desk-like cabinet • Central processor with 32K bytes of MOS memory • One RXO 1 dual floppy disk unit with 512K bytes of data storage • VT52 video/keyboard transaction terminal Options include: • Additional memory up to a total of 56K bytes • Additional dual floppy disk unit in the same cabinet • Choice of printers (30 cps up to 300 Ipm) • Cartridge disk drives (2.5 million bytes removable; 5.0 fixed) • Up to three video or hard-copy terminals • 2780 communications package and CTS-300 DICAM, providing both batch and interactive communication capabilities. Further information may be found in the DEC Datasystem 320 Family Service Manual, EK-DDS03-SV. 69 0322 VT52 (OPTIONAL RX01) Basic 322 System 70 0322 MR-0781 Optional Cabinet and Printer 71 0322 Basic 0322 System, Rear View with Door Removed 0322 System Model Designations Model Designation D322AInput Power / Frequency Software Category 0322H9820RXV11PDP-11/03VT52LAV11- • DS3RKH967RKV11- AA 115/60 A A W DA JA AE PA AA HK DA ·Model AA + LAV11 = Model BA Model AD + LAV 11 = Model BD Model AY + LAV11 = Model BY Model AZ + LA V 11 = Model BZ 72 AD 230/50 A B W DO JB AF PO AD HL DB AY 115/60 C AZ 230/50 C t t same as AA column same as AD column ~ 0322 0322 SPECIFICATIONS· SEE 0324 SPECS FOR PRINTER SPECS BASIC 322 116V 60HZ POWER CONNECTOR 230V 50 HZ OPTIONAL CABINET 115V 60HZ 230V 50HZ G. G. 16© G. G. 15© --WI I 16~ WI I 16~ NEMANO. DEC PIN 5-15P 90·08938 6-15P 90-08853 6·15P 90'()8938 6·15P 90'()8853 AMPERAGE 12 AMPS 6 AMPS 12 AMPS 6 AMPS BTU/HOUR 3400 3400 1400 1400 HEAT DISSIPATION 1000W 1000W 400W 400W SHIPPING WEIGHT (APPROXIMATEI 400 LBS 182 KG 400 LBS 182 KG 300 LBS 136 KG 300 LBS 136KG ·SPECIFICATIONS HAVE BEEN FIGURED ON THE MAXIMUM CONTAINED IN EACH UNIT. MR-0782 Modules Included In the Basic System Processor KD 11-P (M7264-BB) Resident memory addressed as bank 0 CPU refresh disabled Powers up to 173000 Or KD11-Q (M7264-YB) No resident memory CPU refresh disabled Powers up to 173000 Memory MSV 11-B (M7944) 4K RAM Three in basic system with KD 11-P Addresses start at bank 1 Refreshed by REV 11-C Or 73 0322 MSV 11-C (M7955-YO) 16K RAM One in basic system with KD 11-0 Addresses start at bank 0 Internal refresh Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 9600 baud EIA One stop bit, eight data bits, no parity RX01 Floppy Disk Interface RXV 11 (M7946) First device address (disk 0) 177170 First vector 264 Second device address (disk 1) 177150 Second vector 270 Bootstrap / Diagnostic REV 11-C (M9400-YC) Bootstrap enabled Diagnostics enabled Refresh enabled for MSV 11-B Refresh disabled for MSV 11-C Terminator lEV 11 (M9400-YB) 120 n terminator 74 0322 Optional Modules for Recommended Expansion LA 180 Printer Interface LA V 11 (M7949) Device address 177510 Vector 200 Or LPV 11 (M8027) Device address 177510 Vector 200 RK05 Disk Interface RKV11-D Interfaced to computer by M7269 See the "CPU / Options" section for more detailed information. Communications Interface DUV11 (M7951) Device address 160010 Vector 440 DL V 11 (M7940) Device address: console 177560 second terminal 176500 Vector: console 60 second terminal 300 75 D322 A B D C KD11-P (M7264-BB) CPU BACKPLANE 2 MSV11-B (M7944) REV11-C (M9400-YC) FRAME 1 3 MSV11-B (M7944) DLV11 (M7940) (M9400-YE) MSV11-B (M7944) 4 ~v,.-xx ........ { BC05L-XX ....RXV11 (M7946) (M9401) EXPANSION BACKPLANE FRAME 2 ~V'A-XX - - 3 - - 4 BCV1A-02 (M94CJO.YD) - 2 BC05L-XX { - (M9401) EXPANSION BACKPLANE FRAME 3 3 4 - - - - TEV11 (M9400-VB) * -MR-0783 -IN MOST CASES M9400 MODULES ARE PLACED IMMEDIATELY FOLLOWING THE LAST MODULE IN THE SYSTEM. THE TEV11, HOWEVER, IS AN EXCEPTION TO THE GENERAL RULE. IN THE BUSINESS PRODUCTS SYSTEMS IT IS PLACED IN THE LAST SLOT OF THE LAST BACKPLANE IN ORDER TO MINIMIZE NOISE. 0322 Module Utilization Drawing for Basic System Using PDP-11 /03-JA or - JB CPU Box 76 0322 A B D C KD11-P (M7264-BBI CPU BACKPLANE FRAME 1 2 MSV11-B (M79441 REV11-C (M94OC)..VCI 3 MSV11-B (M79441 DLV11 (M79401 (M9400-YEI MSV11-B (M79441 4 - BC05L-XX DCV'D-XX { (M94011 RXV11 (M79461 EXPANSION BACKPLANE 2 MSV11-B (M79441 LAV11 (M79491 FRAME 2 3 MSV11-B (M79441 MSV11-B (M79441 4 (M9400-VD) DLV11 (M79401 BCOSL-XX RXV11 (M79461 (M94011 EXPANSION BACKPLANE FRAME 3 2 - 3 .. - 4 TEV11 (M9400-VBI - RKV11 (M7269) MR-0784 0322 Module Utilization Drawing for Recommended Expanded Systems Using PDP-11 /03-JA or -JB CPU Box 77 0322 A B o C KD11-Q IM7264-YBI CPU BACKPLANE FRAME 1 MSV11-C IM7965-YDI 2 3 4 REV11-C IM9400-YCI DLV11 IM79401 IM9400--YEI RXV11 1M79481 ---t BC05L-XX IM94011 EXPANSION BACKPLANE FRAME 2 ~"-xx 2 -- 3 - 4 IM9400-YDI { BC05L-XX IM94011 EXPANSION BACKPLANE FRAME 3 3 -- 4 TEV11 IM9400-YDI MR-0786 0322 Module Utilization for Basic System Using POP-11 /03-JC or -JO CPU Box 78 0322 B A D C KDll.Q (M7264-YB) CPU BACKPLANE FRAME 1 2 MSVll-C (M7965-YD) 3 MSVll-C (M7965-YD) (M9400-YE) 4 REVll-C (M9400-YC) ~ BC05L-XX 8CVI8-XX { 1""""'"'1 EXPANSION BACKPLANE FRAME 2 BCV1A-XX (M9401) DLV11 (M7940) 2 DLVll (M7940) RXVll (M7946) 3 RXVll (M7946) LAV11 (M7949) 4 (M9400-YD) RXVll (M7946) { BC05L-XX ........ RKVll (M7269) (M9401) EXPANSION BACKPLANE FRAME 3 2 - - 3 - - 4 - TEVll (M9400-YB) MR-0786 0322 Module Utilization for Recommended Expanded Systems Using POP- 11 /03-JC or -JO CPU Box 79 0324 0324 The standard Datasystem 324 includes the following. • Stylized cabinet and desk • Central processor with 32K bytes of MOS memory • One RK05J removable disk drive with a capacity of 2.4 million bytes of data • One RK05F fixed disk drive with a capacity of 4.S million bytes of data • VT52 video / keyboard transaction terminal Options include additional memory up to a total of 56K bytes. Further information may be found in the DEC Datasystem 320 Family Service Manual, EK-DDS03-SV. VT52 TABLE CPU Basic 324 System so 0324 RK05J o DO IIlrn'IOOOI iI!jj/,IOODD 111111111111111111111111111111111111111111111111111111 Optional Cabinet and Printer 81 0324 0324 System Model Designations Model Designation D324AInput Power / Frequency Software Category 0324H9602RKV11PDP-11/03H970VT52LAV11-RXV11-Model AA + LAV11 Model AD + LAV11 Model AY + LAV11 Model AZ + LAV11 AA 115/60 AD 230/50 A A A B CD DB JB DA AF PO DO CC DA JA DA AE PA DA AY 115/60 C AZ 230/50 C t t same as AA column same as AD column {- {- Model BA Model BD Model BY Model BZ D324 SPECIFICATIONS' PRINTER LA180 115V 60HZ 15 A POWER CONNECTOR NEMA NO. DEC PIN 230V 50HZ 15A RK05 CABINET 230V 50HZ CPU CABINET 115V 60HZ 115V 60HZ 30AW 30AW 30AW 15·30 P 12-11193 15·30 P 12-11193 15·30 P 12-11193 230V 50HZ 20A X VT52 DESK 115V 60HZ 15A 230V 50HZ 15A II -II -- @G@ @@ ©~ ©~ 5·15 P 90-08938 6·15 P 90-08853 AMPERAGE 3A 1.5A 24A 6A BTU/HOUR 1023 1023 1400 1400 66·20 P 12-11192 5·15 P 90-08938 6-15 P 90-08853 24A 6A 1A .5 A 3400 3400 400 400 HEAT DISSIPATION 300W 300W 400W 400W loo0W 1000W 118W 118W SHIPPING WEIGHT (APPROXIMATE) 120 LBS 55 KG 120 LBS 55 KG 300 LBS 136 KG 300 LBS 136 KG 400 LBS 182 KG 400 LBS 182 KG 225 LBS 102 KG 225 LBS 102 KG • SPECIFICATIONS HAVE BEEN FIGURED ON THE MAXIMUM CONTAINED IN EACH UNIT. 82 MR·0790 0324 Modules Included in the Basic System Processor KD 11-P (M7264-BB) Resident memory addressed as bank 0 CPU refresh disabled Powers up to 173000 Or KD11-Q (M7264-YB) No resident memory CPU refresh disabled Powers up to 173000 Memory MSV 11-B (M7944) 4K RAM Three in basic system with KD 11-P Addresses start at bank 1 Refreshed by REV 11-C Or MSV 11-C (M7955-YD) 16K RAM One in basic system with KD 11-Q Addresses start at bank 0 Internal refresh Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 9600 baud EIA One stop bit, eight data bits, no parity 83 0324 Disk Drive Interface RKV11-D Interfaced to computer by M7269 Device address 177400 Vector 220 Bootstrap / Diagnostic REV11-C (M9400-YC) Bootstrap enabled Diagnostic enabled Refresh enabled for MSV 11-B Refresh disabled for MSV 11-C Terminator TEV 11 (M9400-VB) 120 n terminator Optional Modules for Recommended Expansion LA 180 Printer Interface LAV 11 (M7949) Device address 177510 Vector 200 Or LPV 11 (M8027) Device address 177510 Vector 200 84 0324 RX01 Floppy Disk Interface RXV 11 (M7946) First device address (disk 0) 177170 First vector 264 Second device address (disk 1) 177150 Second vector 270 Communications Interface DUV11 (M7951) Device address 160010 Vector 440 DL V 11 (M7940) Device address: console 177560 second terminal 176500 Vector: console 60 second terminal 300 85 0324 A B o C KD11-P IM7264-8BI CPU 2 MSVll-B IM79441 REV11-C IM9400-YCI BACKPLANE FRAME 1 3 MSV11-B IM79441 DLVll IM79401 4 IM9400-YEI MSVll-B IM79441 OCV1B-XX { EXPANSION BACKPLANE FRAME 2 - IM94011 RKV111M72691 -- -- 3 -- -- 4 IM9400-YD) -- BC05L-XX OCV1A-XX { EXPANSION BACKPLANE FRAME 3 BC05L-XX IM9401) - 2 - -- 3 -- -- 4 TEV11 IM9400-YBI * -MR-0791 *IN MOST CASES M9400 MODULES ARE PLACED IMMEDIATELY FOLLOWING THE LAST MODULE IN THE SYSTEM_ THE TEVll, HOWEVER, IS AN EXCEPTION TO THE GENERAL RULE_ IN THE BUSINESS PRODUCTS SYSTEMS IT IS PLACED IN THE LAST SLOT OF THE LAST BACKPLANE IN ORDER TO MINIMIZE NOISE_ 0324 Module Utilization Drawing for Basic System Using PDP-11 /03-JA or - JB CPU Box 86 0324 A B D C KD11·P (M7264-BB) CPU BACKPLANE 2 MSV 11·B (M7944) REV11-C (M940O-VC) FRAME 1 3 MSV11·B (M7944) DLV11 (M7940) (M9400-VE) MSV11·B (M7944) 4 ...... BC05L-XX --1 (M9401) RKV11 (M7269) 2 MSV11·B (M7944) LAV11 (M7949) 3 MSV11·B (M7944) MSV11·B (M7944) 4 (M9400-VD) DLV11 (M7940) EXPANSION BACKPLANE FRAME 2 BC05L-XX OCV'A-XX { (M9401) DLV11 (M7940) RXV11 (M7946) EXPANSION BACKPLANE 2 - FRAME 3 3 .. - 4 TEV11 (M9400..VB) MR-0793 0324 Module Utilization Drawing for Recommended Expanded Systems Using PDP-11 /03-JA or -JB CPU Box 87 0324 A B o C KD11.Q (M7264·YBI CPU 2 MSV11-C (M7955·YDI BACKPLANE FRAME 1 4 BCV1B-XX { REV11-C (M9400-YCI DLV11 (M79401 (M9400-YEI RKV11 (M72691 BC05L-XX - (M94011 - 2 EXPANSION BACKPLANE FRAME 2 - 3 -~V1A-XX 4 { .. (M9400-VD) BC05L-XX (M9401) EXPANSION BACKPLANE FRAME 3 4 TEV11 (M9400·YB) MR·0792 0324 Module Utilization for Basic System Using POP-11 /03-JC or -JO CPU Box 88 0324 A B o C KD11-Q IM7264-YBI CPU BACKPLANE 2 MSV11-C IM7955-YDI FRAME 1 3 MSV11-C IM7955-YDI IM9400-YEI 4 ~V'B-XX REV11-C IM9400-YCI BC05L-XX { ..EXPANSION BACKPLANE FRAME 2 ~V'A-XX EXPANSION BACKPLANE FRAME 3 IM94011 DLV111M79401 2 DLV11 IM79401 RKV111M72691 3 DLV11 IM79401 LAV111M79491 4 IM9400-VDI RXV111M79461 BC051.-XX { IM9401) - 2 - - 3 - - 4 -- TEV11IM9400-YBI MR-0794 0324 Module Utilization for Recommended Expanded Systems Using POP-11 /03-JC or -JO CPU Box 89 0325 0325 The D325 system, with DIGITAL's fully supported CTS-300 software license and DIBOL instruction set, includes the PDP-11 /03 central processor, 64K bytes of MOS memory, bootstrap loader, serial line interface, and VT52 CRT console terminal. There is an RLV 11 controller with dual five-megabyte removable disk drives (RL01) for use as a system device and as a primary backup and load device. This configuration is arranged in an H9602 cabinet and an H9532-AA desk. Space is reserved in this configuration for a printer. Any of the following may also be added: additional RLO 1 disk drives plus cabinet, dual floppy disk unit, choice of four printers, up to three video or hard-copy terminals and / or a 2780 communication package and CTS-300 DICAM (a software package). CPU LA180 OPTIONAL PRINTER 0325 System 90 0325 Model Designation D325A Input Power / Frequency H9602 PDP-11/03 RL01 H9532 VT52 LA180· NE PA ·ModelAA + LA180 Model AD + LA 180 Model BA, Model BD. AA 115/60 AD 230/50 CM NC CN ND AK AA AK AA NF PD 0325 SPECIFICATIONS PRINTER LA 180 115V 60HZ 15A POWER CONNECTOR NEMA NO 230V 50HZ 15A RL01 CA61NET 115V 60HZ 230V 50HZ 30A W 30A W CPU CABINET 115V 60HZ 30AW 230V 50HZ 20A X VT52 DESK 115V 60HZ 15A 230V 50HZ 15A WI. ~ WI. --- @,@ @@ ©© © 5-15 P 6-15 P 15-30 P 15-30 P 15-30 P 66-20 P 5-15 P 6-15 P DEC PIN 90-08938 90-08853 12-11193 12-11193 12-11193 12-11192 90-08938 90-08853 AMPERAGE 3A 1.5A 2.6A 1.3A 8A 4A 1A .5A BTU/HOUR 1023 1023 1100 1100 3400 3400 400 400 HEAT DISSIPATION 300W 300W 300W 300W 960W 960W 118W 118W SHIPPING WEIGHT (APPROXIMATE) 120 LBS 55 KG 120 LBS 55 KG 275 LBS 125 KG 275 LBS 125 KG 350 LBS 159 KG 350 LBS 159 KG 2~ LBS 225 LBS 102 KG 91 102 KG D325 Modules Included In the Basic System Processor KD11-Q (M7264-YB) No resident memory CPU refresh disabled Powers up to 173000 Memory MSV 11-DD (M8044) 64K byte MOS RAM One in basic system Addresses start at bank 0 Internal refresh Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 9600 baud EIA One stop bit, eight data bits, no parity Disk Drive Interface RLV11 (M8013 and M8014) Device address 174400 Vector 160 Bootstrap BDV 11-AA (M80 12) Bootstrap enabled Real time clock enabled (switch B5) 92 D333C LA 180 Printer Interface LPV 11 (M8027) Device address 177514 Vector 200 C/D BUS FOR Q-BUS A INTERCONNECTING D C B KDll-Q (M7264-YB) 2 MSV11-DD(M8044-DA) 3 RLV11 (M8013) 4 RLV11 (M8014) 5 DLV11 (M7940) EMPTY 6 LPV11 (M8027) EMPTY OPTION 8 OPTION 9 BDVll-AA (M8012-YA) MR-4884 0325 Module Configuration Using PDP-11 /03-NC or PDP-11 /03-ND Box D333C The D333C data system with DIGITAL's fully supported CTS-300 software license and DIBOL instruction set includes the PDP-11 /23 microcomputer with 128K bytes of MOS memory, a four-channel serial line interface with bootstrap/terminator and a VT100 CRT console terminal. There is an RXV21 controller for a dual RX02 floppy disk storage medium. This configuration is arranged in an H9642 system cabinet and an H9532 work table. This system can be expanded for greater storage capacity. Model Designation D333C Input Power 1 Frequency H9652 PDP-11/23 VT100 LA180 RX02 AA AD 115/60 230/50 AA NA PA BA AB NB 93 PO BC D333C Compatible Options • An additional 128K bytes memory • Additional video or hard-copy terminals for a total of four • Additional storage medium Second dual floppy disk (1 megabyte storage) • Choice of printers • BATCH or interactive communication software languages: DICAM - Data System Interactive Communications Access Method (for IBM 360/370 hosts) DIBOL - DIGITAL Business-Oriented Language RDCP - 2780/3780 BATCH Communication Package. CONNECTOR 1 CONNECTOR 2 r---------~A--------~'rr---------AA---------, SLOT A PROCESSOR MODULE OPTION 1 HIGHEST PRIORITY SLOT B SLOT C SLOT D ~ ~ ~ ROW 1 KDFll·AA (M8186) ROW 2 MSVll·DD (M8044D) OPTION 2 ROW3 MSVll·DD (M8044D) OPTION 3 ROW 4 RXV21 (M8029) • OPTION 4 ROW 5 DLVll·J (M8043)" OPTION 5 ROW6 LPVll (M8027) OPTION 6 ROW 7 OPTION 7 ROW8 OPTION 8 (LOWEST PRIORITY) ROW9 BDVll (M8012) VIEW IS FROM MODULE SIDE OF BACKPLANE 'NOTE: MUST BE AT CS REVISION 'El' OR HIGHER. "NOTE: MUST BE AT CS REVISION 'E' OR HIGHER. D333 Module Configuration 94 D335C D335C The D335C data system, with DIGITAL's fully supported CTS-300 software license and DIBOL instruction set, includes the PDP-11 /23 microcomputer with 128K bytes of MOS memory, a four-channel serial line interface with bootstrap/terminator, and a VT100 CRT console terminal. There is an RL V 11 controller with 10-megabyte removable RLO 1 dual disk drives for use as a system device and a primary backup and load device. This configuration is arranged in an H9642 system cabinet and an H9532 work table. Space is available in this configuration for a printer. Model Designations D335C Input Power / Frequency H9642 PDP-11/23 RL01 H9532 VT100 LA180· AA 115/60 AD 230/40 AA AK AB AB AK AB NB PD NA PA ·Optional Modules Included in the Basic System Processor KDF 11-AA (M8186) Memory management standard KEF 11-A floating point (optional) Memory MSV 11-DD (M8044) 64K bytes MOS RAM (two in basic system) Addresses start at bank 0 Internal refresh 95 D335C Serial Line Interface DLV 11-J (M8043) (Must be at CS revision "E" or higher.) Console device address 177560 Vector address 60 9600 baud EIA RS423 and RS-232C One stop bit, eight data bits, no parity Disk Drive Interface RLV11 (M8013 and M8014)/RL01 Device address 174400 Vector address 160 Bootstrap BDV 11-AA (M80 12) Bootstrap enabled Real time clock enabled (switch B5) LA 180 Printer Interface LPV 11 (M8027) Device address 177514 Vector address 200 96 D336C CONNECTOR 1 CONNECTOR 2 r-----------------~H~--------~A~--------SLOTA PROCESSOR MODULE OPTION 1 (HIGHEST PRIORITY SLOTB SLOTC SLOT D ~ ~ ~ ROW 1 KDFll·AA (M8l86) ROW2 MSVll·D (M8044D) OPTION 2 ROW3 MSVll·D (M8044D) OPTION 3 ROW4 RLV11 (M8013) OPTION 4 ROW5 RLVll (M80l4) OPTION 5 ROW6 DLVll·J (M8043) * OPTION 6 ROW7 LPVll (M8027) OPTION 7 ROW8 OPTION 8 (LOWEST PRIORITY) ROW9 BDVll·AA (M80l2·YA) VIEW IS FROM MODULE SIDE OF BACKPLANE *NOTE: MUST BE AT CS REVISION 'E' OR HIGHER. MA48B6 0335 Module Configuration D336C The D336C data system, with DIGITAL's fully supported CTS-300 software license and DIBOL instruction set, includes the PDP-11 /23 microcomputer with 128K bytes of MOS memory, a four-channel serial line interface with bootstrap/terminator, and a VT100 CRT console terminal. There is an RL V 11 controller with 20-megabyte removable dual RL02 disk drives for use as a system device and a primary backup and load device. This configuration is arranged in an H9642 system cabinet and an H9532 worktable. Space is available in this configuration for added expansion such as a printer, a serial line interface, synchronous communication, memory, floppy control, etc. 97 D336C Model Designations 0336C Input Power / Frequency H9642 POP-11/23 RL02 H9532 VT100 LA180· AA 115/60 AD 230/50 AA AK AB NA PA AB AK AB NB PO ·Optional Modules Included in the Basic System Processor KOF 11-AA (M8186) Memory management standard KEF 11-A floating pOint (optional) Memory MSV 11-00 (M8044) 64K bytes MOS RAM (two in basic system) Addresses start at bank 0 Internal refresh Serial Line Interface OLV 11-J (M8043) (Must be at CS revision "E" or higher.) Console device address 177560 Vector address 60 9600 baud EIA RS423 and RS-232C One stop bit, eight data bits, no parity 98 D336C Disk Drive Interface RLV 11 (MBO 13 and MBO 14) / RL02 Device address 174400 Vector address 160 Bootstrap BDV 11-AA (MBO 12) Bootstrap enabled Real time clock enabled (switch B5) LA 180 Printer Interface LPV 11 (MB027) Device address 177514 Vector address 200 CONNECTOR 1 CONNECTOR 2 r---------~------~"r---------A--------~ SLOT A PROCESSOR MODULE OPTION 1 (HIGHEST PRIORITY SLOT B SLOTC SLOT 0 ~ ~ ~ ROWl KDFll-AA (M8l86) ROW2 MSVll-D (M8044D) MSVll-D (M8044D) OPTION 2 ROW3 OPTION 3 ROW4 RLVlll(M80l3) OPTION 4 ROW 5 RLVll (M80l4) OPTION 5 ROW6 DLVll-J (M8043) * OPTION 6 ROW 7 LPVl i (M8027) OPTION 7 ROW8 OPTION 8 (LOWEST PRIORITY) ROW9 BDVll-AA (M80l2-YA) VIEW IS FROM MODULE SIDE OF BACKPLANE *NOTE: MUST BE AT CS REVISION 'E' OR HIGHER. MR-4BB7 0336 Module Configuration 99 D336C FRONT VIEW ~18"-. (46 em) r 42" DISK EXPANSION RL01/2 CPU EXPANSION CPU DISK EXPANSION RL01/2 ~ ~ (3815"em) t TABLE - 22" 22" 1'--(56 em)--- ~(56 em)" (Optional) 27" (69 em) 48" (122 em) ~ (BASIC SYSTEM) TOP VIEW ~ Y15ft (4.6 m) ~15ft l' OPTION CABINET CPU CABINET 867 Watts 2948 Btu/hr 370 Ibs (168 kg) 918 Watts 3121 Btu/hr 370 Ibs (168 Kg) -.:r t 30" (76 em) ~ (4.6 m) CRT 150 Watts • 14" 51~5BI~:hr (36 em) (16 kg) + t 30" (76 em) I • MR4BBB 0325, 0335, and 0336 Oata Systems 100 TELEPHONE COMPANY SYSTEM TELEPHONE COMPANY SYSTEM CC1A PDP-11V03 SYSTEM A non-DIGITAL terminal is used with this system. The terminal is a Tektronix'M 4023 AN. The Tektronix terminal must be an "AN" version and is configured for 9600 baud and checked out by the Western Electric Company (WECO) representative. For installation, a null modem is provided by DIGITAL Field Service. Use of an H312 null modem will cause receive status errors, therefore a BC03M-L cable is recommended for installation checkout. The terminal will be connected through the null modem directly to the DL V 11, by-passing the Bell interface cabinet located on top of the PDP-11 V03 cabinet. After system check, the WECO representative will connect the Bell interface. When running the Tektronix terminal after the screen is full, the first seven characters will be scrambled owing to terminal and software incompatibilities. Hit the ERASE key or change the baud rate on the back of the terminal (rotary SW) and DL V 11 interface to 2400 baud. The diagnostics will run at this lower speed. Remember to return the system to 9600 for the customer. Step 4 of the installation procedure asks the DIGITAL Field Service engineer to show that the floppy disk will boot from drives 0 and 1. Other versions of the monitor would only boot from drive 0, but recent shipments of this system should contain the newer floppies that will boot from both drives. Step 4 also asks the DIGITAL engineer to demonstrate the clock diagnostic VKAHAO for at least 10 minutes. After several passes, the "TIME" printout must have incremented to indicate that the clock is running. The clock is unlike most PDP-11 real time clocks in that it is only a line "BEVNT" which goes to the CPU causing an interrupt. If it is not working, check the "LTC" switch on front panel and items in FA&T checklist, sheets 15 and 16. For troubleshooting, the two backplanes can be separated by removing the M9400-YE in slot 4 and switching DRV 11 No. 1 and DL V 11 (see sheet 11 of configuration). This will allow the BA 11-MA to function as a system without the BA 11-"ME connected. Remember to reconfigure to the original condition when finished. 101 TELEPHONE COMPANY SYSTEM DRV 11 No. 1 and DRV 11 No.2 must be set up properly for the slot position where they are located or the wrong lines may be connected to them. The PDP-tt / V03 System Manual, EK-11 V03-TM, should be available to the Field Service engineer for 11 V03 and diagnostic information. The Microcomputer Handbook is also a good source of technical PDP-11 V03 information. CC# 1A Diagnostic Check List RXDP Diskettes 0#1 0#2 0#7 0#10 0#15 0#25 0#26 0#30 SPECIAL DECX 4 o o 11 V03 o o o o o o o o o o VKAAAO VKABAO VKACBO VKADBO 1-VKAHAO DL V 11 M7940 - - VKAEB 1 DRV11 M7941- 2 - VKAFBO MSV 11 CD M7955 - ZKMADO RXV11 M7946 - 3 - ZRXBEO ZRXAEO REV M9400-Y A - - ZM9ADO Basic Inst. Test EIS FIS TRAPS TIME #25 #25 #25 #25 #25 #25 #25 #25 #15 #15 #10 1. Run two passes minimum, approximately 10 minutes and check that "TIME" printout is incrementing. 2. Use a BC08R-1 loopback cable for testing. Diagnostic will come up testing DRV 11 No.2; therefore, after several passes, halt CPU and change address and vector information as shown: 102 TELEPHONE COMPANY SYSTEM $DXO DZaUJ-C 21-JUL-76 R .R VKAFBO } TESTING OF DRV11 ENII OF PASS END OF PASS END OF PASS 004410 @1200/167770 167760 ) 001202/167772 167762 001204/167774 167764 001206/167773 167763 001210/000300 310 001212/000302 312 001214/000304 314 001216/000306 316 001220/167770 @200GEND OF PASS END OF PASS 2 MODIFICATION OF PROGRAM ADDRESS AND VECTORS FOR DRV11 1 TYPE L.F. AFTER ENTRY ONLY. TYPE C.R. ON LAST ENTRY. TYPE 200G. TESTING OF DRV11 1 004402 @ 3. Run ZRXBEO before running ZRXAEO. 4. Special DECX map: .MAP CF'AFO AT CPBIO AT FF'AFO AT DHCHO AT BMCMO AT RXArtO AT 017752 STAT 040020 021502 STAT 040020 023242 STAT 040020 024522 STAT 040020 025430 STAT 040020 030054 STAT 140000 5. Diagnostics available on single floppy. NOTE This is not an official software package and is intended for field use only. ENTRYt FILNAM.EXT 000001 000002 000003 000004 000005 000006 000007 000010 000011 000012 000013 000014 000015 000016 000017 000020 RXDP .BIN UF'D2 .BIN XTECO .BIN VKAAAO.BIC VKABAO.BIC VKACBO.BIC VKADBO.BIC VKAEB1.BIC VKAFBO.BIN ZKMAB1.BIC ZKMADO.BIC ZRXBEO.BIC ZRXAEO.BIC ZM9ADO.DIC VKAHAO.BIC CHAIN .CCC DATE LENGTH START 7-MAR-78 7-MAR-78 7-MAR-78 7-MAR-78 7-MAR-78 7-MAR-78 7-MAR-78 10-MAR-78 10-MAR-'78 10-MAR-'78 10-MAR-78 10-MAR-78 10-MAR-7S 10-MAR-78 4-APR-78 5-APR-78 17 30 26 17 17 16 12 7 6 9 9 17 20 7 17 1 000050 000071 000127 000161 000202 000223 000243 000257 000266 000274 000305 000316 000337 000363 000372 000413 103 TELEPHONE COMPANY SYSTEM CC # 1A Module Jumper Information Module Option Jumpers Microcomputer Handbook Page M7264 CPU W4, W6, W91N 243,236 M7955 M7955 MSV11CD MSV11CD 1-5 ON, 6-8 OFF 3, 6, 7, 8 OFF, others ON 244 244 M7941 DRV11 No.1 A3, A121N [A = 767760] V4, V51N V = 310 M7941 DRV11 No.2 A 12, V3, V4, V51N [A = 767770] 290 V = 300 290 M9400-YA REV11-A Remove W2 380 M7940 Refer to Micro Handbook 259 DLV11 104 TELEPHONE COMPANY SYSTEM DIGITAL EQUIPMENT CORPORATION MAYNARD, MASSACHUSETTS DATE 14 JUN 78 MANUFACTURING SPECIFICATION TITll sees cnmn COro..£ 00, lA (CC ~O, lA) COflCiJPATlOO REVISIONS jcHG NO REV DESCRIPTION A DLV1l is current ly being shi[lped wi th system due to unava il ab i 1ity of DLVll-F. Change package to reflect DLVll instead of DLVll-F. ORIG -'A 105 APPD BY DATE J. Tomaswick /14/78 J. Tomaswick 6/14/7E SIZE ICODE EN-olO'l· J6-N1721JI2) DATE NUMBER MFGENG-O CONF -0004 I REV A TELEPHONE COMPANY SYSTEM - MANUFACTURING SPECIFICAnON TITLE CONTINUATION SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION INDEX PAGE ECO REV 1 A 1 Index 2 Configuration Approvals 3 Users Page. 4 System Description. 1 A 5 Configuration Notes 1 A 6 Configuration Notes 7 Equipment List. 1 A 1 A * * * 8 Installation Procedure. 9 Cabinet Layout. 10 Cabinet Modification. 11 Box Layout. 1 A 12 Bus Sequence. 1 A * * * 13 Cab 1e Layout. 14 Device Address Assignment 15 Telco FA&T 11V03WA Checkl ist. 16 Telco FA&T 11V03WA Checklist. 17 Change Page 1 A * 1 A * I"i I I MFGENG~~'t:~~r-0004 J E ~c 11-11.11-10....... 71 CODE R:V SHEET -L. OF --1L- 106 TELEPHONE COMPANY SYSTEM - MANUFACTURING SPECIFICAnON TITLE SCCS CONTROL CONSOLE NO. lA CONTINUATION SHEET (CC NO. lA ) CONFIGURATION CONF IGURATION APPROVALS Olgihl Account Representative Digital ProJ ect Manager Olgltal Manufacturing Engineering Manager 01 gHa' Quality Control Manager tHgita' F1e1d Service Product Support 0igital TELCO Engineering Ofagnostlc Englneering Production Manager * CONFIGURATION REVIEWED Be" La6s Representative Western Electric Purchasing *Any review of these specifications by any Bell System representative shall be for general arrangement of the work and shall in no case relieve you in any way of your responsibilities as defined by our purchase orders. I -A SIZE ICODEI DEC It-(J.ZHOU-HI7Z HUMBER MFGENG-O CONF-0004 SHEET _2_ OF 107 1* REV 1L- TELEPHONE COMPANY SYSTEM - MANUFACTURING SPECIFIC AnON TITLE CONTINUATION SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION TO THE USERS OF THIS DOCUMENT: This is a Digital Manufacturing Specification for a DEC system purchased by Western Electric. Configuration approvals are included 1n order to assure that a system is manufactured in accordance with the latest known requirements. The information conta1ned herein 1s consistent w1th the 1nformat10n included 1n: Bell Telephone Laboratories - SOli lP039-01 Western Electric J-Drawing JlC016K-l DEC Standard Price L1st * It is imperat i ve that the Bell Laboratori es and/or Western El ectri c Purchas i ng s i gnat or ies contact the Di gi ta 1 Account Representat i ve in the event of changes to the SO and/or J-drawing. Should these changes aff~ct the contents of this document, the Digital Account Representative shall contact the Digital Project Manager who, in turn, shall have this document updated. Conversely, no changes sha 11 be made to the product manufactured under thi s spec i fi cat ion without written notification to and expressed approval of the Bell System signatories. When Digital issues a new price list, the Digital Account Representative shall assure that all requ; site equ i pment cont; nues to be offered under the DEC codes listed herein. If any of these items is no longer listed, either of the following procedures shall apply. 1) 2) The Digital Account Representative shall notify the Bell Laboratories and Western Electric signatories of changes to nomenclature and packaging in order to include the then current equipment lists in the next issued SO and J-drawi ng. -orThe Digital Project Manager shall convene a configuration review committee meeting (attended by all the signatories of this document or thei r des i gnated represent at i ves) for the purpose of 1dent Hying the alternate equipment to be used for this project configuration. At such a t1me, the short-term requirements and avallabil it1es of the equ i pment 1i sted herei n shall be determi ned and the appropri ate trans1tion plans shall be made. Digital Field Service shall adhere to the information contained in this document. If the end-user wishes anything different, the end-user should be told to contact the appropriate Western Electric Regional Office. This specification is included with all shipments of DEC equipment for this project. I S,}E1CODEl Me: l"(III.·lOl~"J 108 A NUMBER I REV I MFGENG-O COOF -0004 * SHEET --L- OF ...l1_ TELEPHONE COMPANY SYSTEM - MANUFAcruRING SPECIFICATION TITLE CONTINUATION SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION SYSTEM DESCRIPTION The PDPllV03-WA configuration is a subsystem of the switching control center system's control console No. lA. The control console No. lA is used to provide remote maintenance, alarm, surviellance and control of unattended electronic telephone switching offices. Its most important function is to provide remote control capabilities to restore the telephone switching office to service after certain types of failures. The reliability and availability of the control console are extremely important due to its potential use during cr.itical periods where telephone service in a particular telephone switchin9 office has been interrupted. It may be used in continuous service (24 hr/day) application. The microcomputer is connected via the DLVll to a CRT for display of alarm data as well as input of remote control requests. The connect ion is accomplished via a null mOdem cable to provide the proper handshak i ng and data interchange. A telemetry data network is driven via a DRVll and is the primary link from the control console to the remote telephone switching office. Another DRVll sends data to a circuit that drives a local alarm display. The microcomputer configuration carries a Western Electric designation of JIC016K-1. The telemetry equipment, local alarm interface and cables (including a null modem cable) have a designation of JIC016L-1. The CRT is designated JIC016M-1. I SI]E ICODEI DeC I~ltll 1011..... 71 A NUMIER IMFGENG-O CONF oi()004 SHEET 109 I REV A -L OF -!l..- TELEPHONE COMPANY SYSTEM - MANUFAcnJRING CONTINUATION SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION TmE CONFIGURATION NOTES 1. This is a fixed configuration. There is no optional equipment. 2. DiagnostiC media is RXDP diskette. 3. The DLVll will be configured as follows: EIA, 9600 BAUD, 8 data bits. 1 stoP. no parity, framing error halt strap ...... removed. Other options not specified here shall be set to DEC Standards. 4. The REVll will be configured as follows: ROM enabled. 5. At the time of installation or service call. a working 9600 BAUD terminal compatible with the system must be made available by the customer. 6. Warranty is 90 days from date of in~tallation or six months from ship date, whichever comes first. 7. The clock operation must be verified by running MD-11-DVKAH-XX a minimum of two passes. See 1tem 7 on page 15. B. The abil1ty of the system to boot MAINOEC 11 - DZQUJ'",DO from both drive 10 and 11 must be demonstrated. 9. System enviromenhl requirements will be in accordance with Bell System BSP - Section 760-251-150. "Site Prep and Enviromental Considerations for Minicomputers in Standard Systems". 10. For installation testing. a null modem is required between the DLV11-F serial 11ne unit and the 9600 BAUD terminal. DEC shall provide th1s null modem during installation testing of PDP 11 V03/WA. 11. Installer will remove DRV11 11 and #2 and visually ver1fy the vector address on each per the Device Address Assignment Sheet. Us1ng DEC diagnostic MD-llDVKAF-B only one DRVll will be run at a time. 12. Max1mum current limitat 10n on power strip for use by customer 1s four (4) amps. 13. The DRVll's will have a label placed on the handle on side 2 dep1ct1ng the address and vector of the DRVll as per the follow1ng example: VECT 310 DRVll 11 ADD 767760 or VECT 300_ DRVll 12 ADD 767770 DMA refresh disabled. l "I" I "ZE CODE I Me 11-(...'·101 ..... " 110 NUMBER IA SHEET _5_ OF --.!Z.. IMFGENG-O CONF -0004 REV TELEPHONE COMPANY SYSTEM - MANUFACl'URlNG SPECIFICATION TITLE CONTINUATION SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION CONFIGURATION NOTES (cont.) 14. In order to assure a higher quality level, pages 15 and 16 (Telco FA&T llV03WA, SCCS Control Console NO. lA (CC NO. lA) Configuration Checkl1st) is to be completed by the PSI personnel for each system. Their initials wl1l signify that they have completed or verified each indicated procedure. ICODEI NUMBER 1RI:V A MFGENG-O CONF -0004 * I '~E IHEET ~ 0' -!L 111 TELEPHONE COMPANY SYSTEM - MANUFAcnJRING TlTLI CONTINUATION IHIET SCCS CONTROL CONSOLE NO. 1A (CC NO. 1A) CONFIGURATION EQUIPMENT LIST One (1) llV03WA composed of the following: ill!1 .9ll DE SCR I PTI ON 1 1 1l/03-KA consisting of: -MSVll-CD -KEVllA -KDll-R -BAll-MA 2 2 DRVll 3 1 DLVll 4 1 MSVll-CD 5 1 REVll-A 6 1 BAll-ME 7 1 BCVIB-06 8 1 H984-DA 9 1 BC05C-25 10 1 RXVll-BA IS'IE JCODEI MFGENG~N~BIF~ooo41lEV DeC Ifo<lIIll..._7, 112 TELEPHONE COMPANY SYSTEM - MANUFAcruRING IPEClFlCAnClN CONTINUATION IHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION TITLE INSTALLATION PROCEOURE The control console No. lA consists of: -DEC Processor, JIC016K-l -Interface Unit, JIC016L-l -Tektronix model 4023AN CRT Terminal, JIC016M-l After the above equipment has arrived at the site storage loc"ation, the following procedures and guidelines shall be followed •. 1. The Western Electric (WECO) installer shall verify that the CRT terminal is operat iona 1. 2. The WECO ins ta 11 er sha 11 make arrangement s for the DEC representat i ve to be at the job location and will secure permission for movement of the DEC processor from the storage location to the job site. 3. At the job site, WECO installation shall provide all labor required for unpacking and placing the equipment',in the desired location. The DEC representative will supervise the unpacking and placement of DEC equipment and verify any evident damages for subsequent claims. 4. After the WECO installer has mounted the interface unit on the processor and lowered the interconnect cab 1es to the processor area, the DEC i nstaller will run diagnostics on the processor. The DEC installer will provide the null modem cable to interconnect the DLVll to the CRT terminal for testing. In addition to DEC diagnostics, the DEC installer shall demonstrate the capability to boot from drive 0, Drive 1 and demonstrate that the system clock is operat iona 1. 5. Upon successful completion of the diagnostics, the DEC installer shall connect the following cables, previously lowered by the WECO installer, to the processor. "JI-DRV(2) .side up" "J2-DRV(2). side up" "J-DLV.side up" "JI-DRV(l).side up" "J2-DRV(1).side up" AC Power Plug 6. The DEC installer shall demonstrate that the removal and reinsertion of processor boards for cable connection did not affect processor operation. 7. Upon successful completion, the WECO installer will accept the DEC processor and initiate control console No. lA diagnostics. "1E ICODE I 1" 113 I REV A· IHEET _8_ OF ...!L NUIilIER I MFGENG-O CONF-0004 TELEPHONE COMPANY SYSTEM - MANUF At"I'lJlUNG TITLE SCSS CONTROL CONSOLE NO. CONTINUATION SHEET lA (CC NO. lA) CONFIGURATION CAB I NET LAYOUT digital rxtil IIIII~ IIIII {I1II ~ 11111 digital pdp 11/03 I<L!)~I ~ I;J 111E ICODEIMFGENG~u~eN~~0004 IR~V IHEET ..2- OF -1.L 114 TELEPHONE COMPANY SYSTEM CONTINUATION SHEET TITLE SCCS CONTROL CONSOLE NO. lA ( CC NO. lA) CONFIGURATION II, II,' •• ,,' 1:1 .·/I/vli"! IJI?, l'rJ lie I"..." II. 1'I~ ..".rn'li/." wilL ItI('I","', IV/ex. I"H· ....~I".IX. 2" ~L·O,.." 51/)(;. D~ BOX SHEET 115 REV * ..l2.- OF .17 _ FGENG-O CONF ·0004 TELEPHONE COMPANY SYSTEM - MANUF At7URIN TITLE SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONTINUATION SHEET CONFIGURATION CABINET LAYOUT A • M7264-YA M7955 M7955 4 M9400-YE (KDII-H) (MSVll-CD) (MSVll-CQ.L 1 M7941 (ORVll 11) REV DEC: 1~1I'l-l"J""71 SHEET 116 -l.L OF --E. TELEPHONE COMPANY SYSTEM - MANUFAcnJRING SPECIFICA 0 TITLE SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONTINUATION SHEET CONFIGURATION BUS SEQUENCE REV A SHEET 117 -.JL OF _ TELEPHONE COMPANY SYSTEM - MANUF ACI'lJRING SPECIFICAnON TITLE sees CONTROL CONSOLE NO. lA (ee NO. lA) CONTINUATION SHEET CONFIGURATION CABLE LAYOUT RXOIBA ID BAll-MA 9 ...j U'l 0 U CXl c:( "r ID N 0o ID -' co U'l0 00 uo CXl ..... J BAll-ME J 1 'IE CODEl NUMBER Io1FGENG-O eOnF -0004 1* REV SHEET lL- OF ...Q. DEC 16o{JIlI-101''''I7' 118 -4 VEe DES I G';A.TIm. DRVll II WECO ['IESIGNATION Parallel 1 REGI5"J1:R ADDRESS 767760 VECTOR ArmRESS 310 PRIORITY 1 KlUNTING CODE +SVf)( 2 Slots BUS LOADS > CO~"'E"'TS Parallel 2 767770 300 3 2 Slots 1 DLVll Serial 777560 60 2 2 Slots 1 RXVll Di sk-Cont 777170 264 4 2 Slots 1 !:j c: l! z 0 1 DRVll 12 1 ~ ...~ ..,c>z DEV ICF ADDRESS ASS IIiN~lErn SO ~ 9600 BAUD ;; ;:; ~0 Z -f m r m co I-- 0 I '" n ~~ r-o'" NOTE: PRIG ~ITY DETERMIN D BY DEVI E CLOSES TO THE (IPU. SEE B S SEQUENCf : PRIOR TY 1 = HIGHEST 0 ~ CIt :z: '"'".... ~ 0 Z :z ~ 'P 0 z C • n ~ 0 ~ 0 0 o ... ~ ... .". I z lit % 0 III I-~:II III < -4 "'C :E: o Z m o o 3: "'C » Z -< en -< en -f m 3: TELEPHONE COMPANY SYSTEM - MANUF ACTlIRlNG SP.."..,.·... •....... N TITLE CONTINUATION SHEET sees CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION TELCO FAn 11V03-WA sees CONTROL CONSOLE NO. lA (CC NO. \A) CHECKLIST INITIAL 1 .) The cab fan power cord shou 1d be plugged into the rear plug of the dual receptacle. (Mounted on side of cab). 2.) DRVll's should have a sticker on the module, side 2 under the cable, giving address, vector and DRVl1 number 1 or 2. 3.) Cables for DRVll should be installed ribbed side up. 4.) Check for a green wire on the console board between TP2 and W4. 5.) All ribbon cables should have the red strip on the right. 6.) Cable from J2 (console board) should be routed behind the switch pane 1. 7.) Run diagnostic VKAHAO as shown. If the time is 000000, the clock is not running. Write the time printed for pass number 2: (it takes 5 minutes per pass). tnxo _.. __ ~ -2.1.=...lUI..-:..2• .~ VK~_ ~L"__. • _ __ __ .B.Uf-. ~---UllLUO 1 ....ltQIIIUOR...2BK ' ___ __ ___ .. _._ . j DVKAH-A J1£tt.QRY·~:5UZ6 _ PASS-oGOOOl ERRQR-OOOOOO RXERROR-OOOOOO TI"E-044416 PASS-000002 ERROR-OOOOOO ~XERROR-OOOOOO TI",-110101 8.) DLVll should be set up for EIA before software is run. (NOTE: Do not ship 70-08360 cable). 9.) 74-16240-0-0 stickers on 11V03 and BAll-ME should be filled out as shown. Note that DRVll '1 is addressed at 767760, vector 310 and is in the llV03 box. DRVl1'2 is addressed at 767770, vector 300 and is in the BAll-ME box. lA S~E1CODE' DEC 1"(~'.)·10l1""71 120 NUMBER I MFGENG-O CONF -0004 'REV * SHEET -15.... OF -1L TELEPHONE COMPANY SYSTEM - MANUFAcruRING SPECIFICAnON tm.I CONTINUAT'ON SHEET SCCS CONTROL CONSOLE NO. lA (CC NO. lA) CONFIGURATION fCPu . .OT MODULE NUMBER A 8 2 3 . 1 2 3 .. , I MODULE NUMBER D -~- H * cs ETCH REV MODULE NUMBER C D BCVIB-06 Rx V II I'¥ I~ DLVII MODULE NUMBER A 8 REV ~- ETCH REV ** ~ * cs REV * *' DR. vII ....z RE~II-A .... .... CS REV C MSV I L MSV I - C l> 8C.VIS-06 ~ DRVII -1 CPU . .OT , -en L<-.D 1 ETCH REV CS REV ETCH REV t~ I~ M *" ~ * • Current Revision INITIAL 10.) Check that the red light (01) on the console board goes off when DC power 1S turned off. -- 11.) Check that drive (I and drive 1 will boot, load and run RXDP diagnostics (Rev D required). -- DEC' IS'ZE ICODEII -" ORe 16-(111)-101_172 NUMSER HFGENG-O CONF-0004 SHEET 121 1 REV A -ll... OF --E Date , 6/14/ 8 1 Change ... 1&.1 III x Requested By Effective Date** J. Tomaswick 6/14/78 III Production Natcrial ~Ianagcr ~Ianager I'agcs Affected Final Approval Change Descript ion 1,4,5,7,8 J. Tomaswic 11,12,14,6 z 0 i= "'z III'" ~I Q" o > ~ DLVll is currently being shipped with system due to unavailabilty of DlVll-F. Change Document to reflect DLVll instead of DLV11-F. 0 ... ~z ~I 0 u J 9 i= <!) z l5 <!) 0 u ~ III 0 0 ~ ffl :E ~~ III m ---- LIJ ~ U) w U) < Cl. > z> c.!) UJ C) Z < a. 0 j: o o U 11.1 LIJ C o ::J :E Z :J: a. < u C .:.. II) Z Ci2 z -« 0 IIll: -z c.!) u.. 0 t U .< "::> LIJ :=;: ~ ~ u ::l LIJ ..J z ~ < ... ;::: Z *- All ships on or !lfter this date must have change incorporated. NOTE: These changes wi 11 be incorporated in the next release cycle. C\I C\I PDP-11L03 LABORATORY SYSTEMS PDP-11L03 The OECLAB-11 103 (11 L03) system includes a POP-11 103 computer, an RXO 1 dual floppy disk drive, and a terminal. The terminal is normally an LA36 OECwriter II or a VT55 OECscope, although some custom systems may have a VT52. Each system also includes some combination of OECLAB modules and an H322 distribution panel to facilitate user I I 0 connections. All models are configured to boot on power-up and halt on BREAK. Early systems have 20K of memory, while later versions use a 16K memory. The figures and tables that follow describe the models, specifications, and components. RX01 11111111 1111111111111111 1IIIIIIiilllllllll::::IIII!11 111111111111111111 1111111 11111111 1111111111:11111111 11111111:::11111111::111111111 111111111111111111 111111111 11 L03 CABINET MR-0767 OECLAB-11/03-CA, -CC, -CO, -GO, -HA, -HC, -HO, -MA, -MC, -MO, -KA 123 PDP-11L03 11 L03 CABINET VT52/vT55 DECSCOPE OECLAB-11 /03-0A, -DC: -~O, -GC, -JA, -JC, -JD, -NA, -NC, -NO, -LA OJ ~ ~ 0 o AC LINE (1t5V,20A; 230V,10Al H322 DISTRIBUTION PANEL nn n n n n n n n U U_UU_UU_UU- -,.L- -LIU MATE-N-LOK II----- c:::::::::Jc:::::::::Jc:::::::::J ____ 1 C~N~ ~ CABLE FROM DECWRITER OR DEC SCOPE MR-0769 124 PDP-11L03 DJ12 ".~ OJ13 DJ14 H322 /" 7014090 /" C..:r I"" A6001 ic AAV11·A J6 P2 ~, M7952 A012 ADV11·A KWV11·A MR·0851 Analog Cable Connections H322 DJ12 DJ13 J10 ~~ 7014060 DJ14 DRV11 MR·0852 Digital Cable Connections 125 ~ DECLAB-11 /03 System Model Designations ~ System Requirements CA CC CD GO DA DC DO GC HA HC Input Power (V) 115 115 220 115 115 115 220 115 115 115 220 Frequency (Hz) 60 50 50 60 60 50 50 60 60 50 50 PDP-11V03 HA HC HD HA JA JC JD JA HA HC HD LA36 DE DH DJ DE DE DH DJ en FA FC FS FA HD RXV11 SA SC SD SA SA SC SD SA SA SC SD H984 (Cabinet) SA SA BB SA SA SA SS SA SA SA BB SA 11 Extension Sox ME ME MF ME ME ME MF ME ME ME MF ADV11 (AD12) KWV 11 (M7952) AAV11 (A6001) DRV 11 (M794 1) ISV11 (M7954) ........ rI VT55 I\:) C 0 W DECLAB-11/03 System Model Designations (Cont) System Requirements CA CC CD GO DA DC DO GC HA HC HD PDP-11V03 JA JC JD HA HC HD JA JC JO HA JA Input Power (V) 115 115 220 115 115 220 115 115 220 115 115 Frequency (Hz) 60 50 60 50 50 60 60 DE OH OJ 50 LA36 ..... I\) "'-.J VT55 FA FC FB RXV11 BA BC BD BA BC H984 (Cabinet) BA BA BB BA BA BA 11 Extension Box ME ME MF 50 50 60 DE FA FC FB FA BO BA BC BO BA BA BB BA BA BB BA BA ME ME ADV11 (A012) KWV 11 (M7952) AAV11 (A6001) " " C ..... ..... I DRV11 IBV 11 (M7954) r0 (,,) PDP-11L03 Specifications 116V POWER CONNECTOR 230 V 60/60 HZ 60HZ PLUG RECEPTACLE PLUG RECEPTACLE wi I ~ @ -~ ~ D OW 6-15R 12·05361 NEMA #6-16P DEC #90-08938 CPU CABINET LA36 VT56 AMPERAGE TYPICAL MAXIMUM 10.1 11.3 2.0 WATTAGE TYPICAL MAXIMUM 860 1340 2730 3210 87.3 182 c:::::Ic::::I 6-16R 12.11204 NEMA #6-16P DEC # 80-08853 CPU CABINET LA36 VT56 2.4 4.8 6.5 1.0 1.2 300 1000 1380 160 300 300 300 550 1020 500 1000 2800 3280 560 1020 500 1000 46.3 102 2&.8 57 87.3 192 46.3 102 2&.8 67 160 BTU/HOUR TYPICAL MAXIMUM WEIGHT KG LBS MA·0770 Modules Included In the Basic System Processor KD 11-F (M7264) in systems purchased prior to Oct. 1, 1977. Resident memory addressed as bank 0 CPU refresh disabled Powers up to 173000 KD11-R (M7264-YA) in systems purchased after Oct. 1, 1977. No resident memory CPU refresh disabled Powers up to 173000 Memory MSV 11-8 (M7944) in systems purchased prior to Oct. 1, 1977. 4K RAM Refreshed by REV 11-A Addressed as bank 1 128 PDP-11L03 MSV 11-CD (M7955-YD) in systems purchased after Oct. 1, 1977. 16K RAM Internal refresh Addresses start at bank 0 Part of the KD 11-R processor option Serial Line Interface DL V 11 (M7940) Device address 177560 Vector 60 300 baud in systems using LA36 DECwriter II terminals 9600 baud in systems using VT55 DECscope 20 rnA active transmitter and active receiver One stop bit, eight data bits, no parity Framing error (BREAK) asserts BHAL T Floppy Disk Interface RXV 11 (M7946) First device address (disk 0) 177170 First vector 264 Second device address (disk 1) 177150 Second vector 270 Bootstrap / Diagnostic / Terminator REV 11-A (M9400-Y A) Bootstrap enabled Diagnostics enabled Refresh enabled in PDP-11 V03-A / E Refresh disabled in PDP-11 V03-F / H 120 Q terminator Additional Modules Included in Optional Systems· Analog-to-Digital Converter ADV11-A (A012) • For configuration details refer to the "CPU / Options" section. 129 PDP-11L03 Digital-to-Analog Converter AAV11-A (A6001) Programmable Real Time Clock KWV 11-A (M7952) Parallel Line Unit DRV11 (M7941) IEEE Instrument Bus Interface IBV 11-A (M7954) Module Utilization Notes 1. Systems purchased before Oct. 1, 1977 have four MSV 11-8 4K memory boards instead of one MSV 11-CD module. They also have a KD 11-F processor instead of a KD 11-H. 2. KD11-R = KD11-H + MSV11-CD KD11-S = KD11-R + KEV11-A 3. All models of PDP-11L03 include the KEV11 EIS/FIS option. A B 1 I C 0 ~ M7264-YA PROCESSOR (KD11·H + KEV111 2 M7965-YD 16K MEMORY (MSV11-CDI 3 M7940SLU (DLV111 4 M94O().YA BOOT! (REVll.AI TERMINATOR M7946 ~'!"~:::ACE (RXV111 M7964 ~~~TI~~~~~!CE IIBV11·AI MR-0771 PDP-11 L03-MA, -MC, -MD, -NA, -NC, -NO 130 PDP-11L03 B A I o C M7264-YA PROCESSOR (KD11·HI + KEV11 2 M7952 PROGRAMMABLE REAL TIME CLOCK (KWV11·AI 3 A012 AID CONVERTER (ADV11·AI 4 I ~~VE~~INATO" M7946 ~N~:~~ACE (RXV111 CPU BOX BCV1B I I I M9401 BUS CONNECTOR M7940SLU (DLV111 A6001 D/A CONVERTER (AAV11.AI 3 4 M7955·YD 16K MEMORY (MSV11·CDI M940()"YA I ~~~~NATOR (REV11·AI M7941 PLU (DRV111 MR-0772 POP-11 L03-KA, -LA A B I I C I 1 M7264-YA PROCESSOR (KD11·HI + KEV11 2 M7952 PROGRAMMABLE REAL TIME CLOCK (KWV11·AI 3 A012 AID CONVERTER (ADV11·AI 4 OCOO~~VE ~~~INATO" M7946 o ~~~:~~ACE (RXV111 CPU BOX BCV1B I 1 M9401 BUS CONNECTOR 2 3 4 I M7940SLU (DLV111 M7955·YD 16K MEMORY (MSV11·CDI M94OQ.YA ~~~~NATOR (REV11·AI EMPTY EMPTY EMPTY EXPANDER BOX MR-0773 POP-11 L03-HA, -HC, -HO, -JA, -JC, -JO 131 PDP-11L03 A B I C J I o M7264-YA PROCESSOR IKDll-HI + KEV11 M7962 PROGRAMMABLE REAL TIME CLOCK IKWV"-AI A012 AID CONVERTER IADV"-AI 3 4 BCV1B OC05~xrE ~'NATOR M7946 ~~~:~:ACE IRXV111 CPU BOX I I M9401 BUS CONNECTOR M7940 SLU IDLVll) M7966-YD 16K MEMORY IMSV"-CDI 3 M7941 PLU IDRV111 4 EMPTY M9400-YA ~~~~NATOR IREV"-AI EMPTY EXPANDER BOX MA-0774 PDP-11 L03-CA, -CC, -CD, -GO, -DA, -DC, -DO, -GC A B I C I I 0 KD"-F PROCESSOR IM72MI 2 KWVll-A PROGRAMMABLE REAL TIME CLOCK IM79621 3 ADV"-A AID CONVERTER (A0121 4 I (M9400-YEI RXV"-A ~;~:~:ACE IM79Ml CPU BOX I I M9401 MSV1'-B 4K MEMORY IM79441 2 MSVll-B 4K MEMORY IM79441 MSVll-B 4K MEMORY IM79441 3 DLVll SLU IM79401 REVll-A~~~~~NATOR IM9400-YAI 4 EMPTY EMPTY EXPANDER BOX MA-0775 Early 16K PDP-11 L03-CA, -CC, -CD, -DA, -DC, -DO Systems 132 PDP-11L03 A B I C -.l -.l 1 KD11-F PROCESSOR IM72641 2 KWV11-A PROGRAMMABLE REAL TIME CLOCK IM79521 3 DRV11 PLU IM79411 4 IM9400-YEI DLVll SLU IM79401 RXV11-A ~N~:~~ACE IM79461 ~~L_X~ BCV1B D CPU BOX I ..L IM9401 I MSVll-B 4K MEMORY IM79441 MSVll-B 4K MEMORY IM79441 MSV11-B 4K MEMORY (M79441 AAVll-A D/A CONVERTER (A60011 EMPTY REVll-A ~~~~NATOR(M9400-YAI EXPANDER BOX MA-0776 Early 16K PDP-11 L03-HA, -HC, -HD, -JA, -JC, -JD Systems A B I C I I 1 KDll-F PROCESSOR IM72641 2 KWVll-A PROGRAMMABLE REAL TIME CLOCK (M79621 3 ADVll-A D/A CONVERTER IA60011 4 IM9400-YEI ~05L_~ BCV1B RXVll-A ~N~:~~ACE IM79461 CPU BOX I .l 1 D 2 I DLVll SLU (M79401 IM94011 MSV11-CD 16K MEMORY IM7955-YDI 3 REVll-A ~~~~NATOR IM9400-YAI EMPTY 4 EMPTY EMPTY EXPANDER BOX MA-0777 Early 20K PDP-11 L03-CA, -CC, -CD, -DA, -DC, -DD Systems 133 PDP-11L03 A B I C I I 1 KD11·F PROCESSOR (M72641 2 KWV11·A PROGRAMMABLE REAL TIME CLOCK (M7952) 3 AAV11·A AID CONVERTER (A0121 (M9400·YEI 4 BC05L_X~ BCV1B RXV11·A ~~~::~ACE (M79461 CPU BOX I 1 D I I DLV11 SLU (M79401 (M94011 2 MSV11-CD 16K MEMORY (M7955-YDI 3 DRV11 PLU (M79411 REV11·A ~~~::'NATOR (M940().YAI 4 EMPTY EMPTY EXPANDER BOX MA-0778 Early 20K POP-11 L03-HA, -HC, -HO, -JA, -JC, -JO Systems 134 11/03-BASED MINC PDP-11/03-BASED MINC/DECLAB-11 IMINC SYSTEMS MODULAR INSTRUMENTATION COMPUTER (MINC) The Modular INstrumentation Computer (MINC) is a real time operating system featuring on-line data storage and BASIC software with graphics, scientific, and laboratory subroutine packages. Each system consists of a MINC chassis, an RX02 dual floppy disk drive, and a VT 105 terminal mounted on a roll-around cart. The MINC chassis houses a power supply, CPU and related modules, and up to eight MINC laboratory options. The physical components of a MINC system are grouped into two categories: items common to all MINC systems, and those that can be purchased as options either when the system is first acquired or at some later time as add-ons. Each MINC system is configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the modules, specifications, and components. All PDP-11 /03 MINC systems include the following standard items. MINC cart, which provides support and transport for: 1. Dual diskette drive (RX02M) 2. MINC chassis (MNCBA) with power supply (H786). This contains: KD11-NA MSV11-DD RXV21 DLV11-J IBV11-A BDV11-A - LSI-11 processor with EIS / FIS - Memory (64K bytes) single board - Diskette drive interface - Four-channel serial ASCII interface - IEEE bus interface - Bus terminator / diagnostic / bootstrap module. 3. VT105 terminal with built-in graphics capability. MINC systems can include some or all of the following lab modules. Analog-to-digital converter (MNCAD) Preamplifier (MNCAG) Dual multiplexer (MNCAM) Clock (MNCKW) 135 11/03-BASED MINe Digital-to-analog converter (MNCAA) Digital input unit (MNCDI) Digital output unit (MNCDO) MINC systems can also include: Dot matrix printer (LA35) Isolation transformer (MNCIT) 110 baud, 20 mA serial line interface (DLV11-KC). VT105 TERMINAL POWER SWITCH FUSE (3AG 3 A SLOW BLOW, 250 V) RX02 FLOPPY DISK MINC System 136 MNCIT (WHEN INSTALLED) 11/03-BASED MINe MINC System Model Designation System Requirements MNC11 -AA -BA Input Power (V) Frequency (Hz) 115 60 MNC11Chassis MNC BA KD 11-NA (M7270) MSV 11 0 (M8044) RXV21 (M8029) IBV11-A (M7954) BDV11-A (M8012) MINC Cart RX02 VT105 LA35 -BC -BD -CA -CC -CD 115 60 1 AA 115 50 1 AA 230 50 115 60 1 AA/BA 115 60 1 115 50 AA/AC BID 1 MA MA 1 MC MA 1 MD MB 1 1 MA MA HE 1 1 MC MA HH 1 1 MC MB HS MNC11-AB MNCAD MNCAA MNCAM MNCDI MNCDO MNCKW MNCAG Cable Console Interface Software Kit (English) Blank Control Panel (MNCBL) • User's options • • As required to fill MNCBA plus one extra 137 11j03-BASED MINe IEEE BUS CONNECTOR (IBV11) CABLE CONSOLE INTERFACE 7015790-0-0 OR 1700211 (LATER MODELS) ~ LINE CORD (115V) \ 1700156-0 ~J/ ~~--=-----I ~~ - (3) LINE CORD DEC TO IEC 17001500 I POWER LINE OUTLET CABLE RX02 INTERFACE 7015574-0 MINC System Cable Connections 138 11/03-BASED MINe 33 31 28 25 22 19 16 13 10 7 6 5 4 3 2 1 ,... N ,... N,... N A N N l? l? ~ 0a: 0 ;~ ~:2 :2~ ; g :2 :2 0 a: N iI ::;: ::;: Q BUS ~ ~ « u« Cl u f- z fZ l? l? ~ ~ ~ Cl '--y---' PDP-11 /03 Module Utilization (MINe) 139 N « ~ ~ ~ ~:2 ;;>! CO INTERCONNECTIONS SLOTS 10 THROUGH 31 MINC OPTION EXPANSION AREA (SEE MNC11- C SYSTEM) C? <} Q BUS OPTION EXPANSION AREA > ~ OECLAB / MINC Specifications ~ ......... 115 V, 50/60 Hz Receptacle Plug 5-15R 12-05351 NEMA No. 6-15P DEC No. 90-08853 RX02 VT105 LA35 MINC Chassis RX02 3.75 3.0 2.0 8 1.75 Plug Power Connector NEMA No. 5-15P DEC No. 90-089 38 MINC Chassis· Amperage Typical Maximum 19 Wattage Typical Maximum 500 1200 Btu/Hour Typical Maximum Weight Kilograms Pounds 460 300 250 225 34.02 75 16.3 36 o 230 V, 50 Hz W I Receptacle 6-15R 12-11204 VT105 LA35 1.5 160 300 460 550 1020 225 46.3 102 34.02 75 * Includes MNCBA chassis with MINC lab modules and RX02 and VT 105. 1.0 250 300 160 550 1020 16.3 36 46.3 102 m l> (J) m c 3C z o 11/03-BASED MINe NOTE MINe option expansion area Is to be used only for MINe lab module add-ons. No Qbus add-ons should be Inserted in this expansion area. No backplane expansion of the MINe system is possible. All Qbus add-ons must be inserted in either slot 5 or 6 (A and B only for double-height options). System-Level Diagnostics Two diagnostic chains are contained on the diagnostic floppy for system troubleshooting. The diagnostic chain MINC 11.CCC provides the required diagnostics for testing the CPU and related modules including the BDV 11, the VT105 option, and MINC lab modules. This chain requires turnaround connectors on SLU 0, SLU 1, SLU 2. For detailed operational information, refer to Book 7, Working with MINe Devices, AA-D572A-TC. The contents of file MINC11.CCC is as follows. R VMNF??I 1 R VKAA??I 1 R VKAB??I 1 R VKAC??I 1 R VKAL??I 1 R VIBB??I 1 R VDLA?? 11 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R ZVTN??I 1 R VMNG??I 1 MINC-AA option sizer program CPU test Extended instruction test Floating pOint instruction set test Traps test IBV11 test DLV11-J test Clock test MNCDI test MNCOO (digital out) diagnostic DI A test AID test VT105 test Termination program The second diagnostic chain MNC 11.CCC provides the required diagnostics for performing a quick check of the MINC lab modules only. The contents of file MNC 11.CC are listed below. R VMNF??I 1 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R VMNG??I 1 Startup I sizer program Floating point instruction set test MNCDI test MNCDO test DI A test AID test Termination program Both programs are stored on the MINC diagnostic disk, available from the Software Distribution Center (SDC). Kit No. ZJ281 - RZ (hard-copy documents) ZJ281 - PX (RX02 floppy) ZJ281 - RX (hard-copy I RX02 floppy kit) 141 11/03-BASED MINe Modules In the Basic System MNC11-AA (115 V, 60 Hz) and MNC11-AB (230 V, 50 Hz) Processor KD11-NA (M7270) With Extended Instruction Set / Floating Point Instruction Set (KEV 11-A, 23003B5) Jumper W 1 installed - crystal clock Jumper W3 removed - enable event line Jumper W6 installed - } ower-u to 173000 (BDV 11) Jumper W5 removed - p p Memory - MSV11-DD (M8044) 64K byte MaS RAM without parity On-board memory refresh Jumper configuration Jumper Jumper State Pin 1 to 3 Pin 1 to 2 OUT} IN Enable 2K I/O page option W2 IN Enable normal system power (+ 5 V) W3 IN Enable normal system power (+ 12 V) W4 OUT Disable battery power (+ 12 V) W5 OUT Disable battery power (+ 5 V) Pin 10 to 14 Pin 16 to 15 IN IN S 1 through S5 ON } Function Implemented Select memory size of 64K bytes Starting address bank 0 142 11j03-BASED MINe Serial Line Interface - DLV11-J (M8043) Number of serial lines: 4 Factory-set address and vector switches Device Address Vector Baud Rate Console SLU 2 SLU 1 SLU 0 777560 776520 776510 776500 9600 300 1200 9600 60 320 310 300 CONSOLE MINC Terminal Distribution Panel 143 11/03-BASED MINe Bus Terminator IDlagnostlc/Bootstrap BDV11-A (M8012) Diagnostic / bootstrap conditions are factory-selected using switch packs. Switch A (E15) RX02 Bootstrap A1 A2 A3 A4 A5 A6 A7 A8 ON ON OFF OFF OFF ON OFF OFF Switch B (E21) RX02 Bootstrap 81 82 83 84 85 OFF OFF OFF OFF ON IEEE Bus Interface - IBV11-A (M7954) Address and vector switch settings: Address 171420 82-1,4 and 5 = ON only Vector 420 8-1 and 5 = ON only Floppy Disk Interface - RXV21 (M8029) Address and vector switch settings: Address 177170 A7 and A8 = OUT only Vector 264 V3, V6 and V7 = OUT only 144 DECLAB-11/MNC DECLAB-11/MNC SYSTEM The DECLAB-11 / MNC is a real time operating system featuring on-line data storage, and FORTRAN software with graphics, scientific, and laboratory subroutine packages. Each system contains as its main components an MNC chassis, dual RL01 disk drives, and a terminal (VT105 or LA36). The MNC chassis houses a power supply, CPU, and related modules, and up to eight MNC- series options. The physical components of the DECLAB system are grouped into two categories: items common to all MNC systems, and those that can be purchased as options, either when the system is first acquired or at some later time. Each DECLAB system is configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the modules, specifications, and components. All DECLAB systems include the following standard items. Mass storage device containing two RLO 1 disk drives MNC chassis (MNCBA) with power supply (H786). This contains: KD11-NA MSV11-DD RLV11 DLV11-J IBV11-A BDV11-A - LSI-11 processor with EIS / FIS Memory (32K word) single board Controller (disk) Four-channel serial ASCII interface IEEE bus interface (optional) Bus terminator / diagnostic/bootstrap module. VT105 terminal with built-in graphics capability DECLAB systems can include some or all of the following lab modules. Analog-to-digital converter (MNCAD) Preamplifier (MNCAG) Dual multiplexer (MNCAM) Clock (MNCKW) Digital-to-analog converter (MNCAA) Digital input unit (MNCDI) Digital output unit (MNCDO) DECLAB systems can also include: Dot matrix printer (LAV 11 + LA 180 or LA35) 110 baud, 20 rnA serial line interface (DLV11-KC). 145 DECLAB-11/MNC MNC CHASSIS ~~!!,!!!!!!~L??/,\ rr~ ;;=~:~~~ :--~'jijji;~,,", II I: I' I, I, I' 11...... EXPANSION I'''''::,~_>-=~~:'-L...J I: CABINET I - - ~ II (H9612) DISK DRIVE : :- - _ _ I UNIT 0 CJ II ----J~ I, I DISK DRIVE UNIT 1 II 11--ll __ ~ -- MASS STORAGE DEVICE CABINET H9610 VIDEO DISPLAY TERMINAL MA·228' DECLAB-11 / MNC System with Optional Units 12 A 115 VAC FAST BLOW FUSE 50/60 HZ 10 A ACINPuT CABLE FROM VT100 OR VT105 115/230 VAC INPUT VT105 OR LA36/LA3B CONSOLE CABLE CABLE FROM RLVll, SLOT 3 AC POWER CABLE TO MNCBA CHASSIS DD~ DD~ MAX ACOUT 3A@230V 6A@115V D DECLAB-11 / MNC Cable Connections 146 DECLAB-11/MNC DECLAB-11/MNC System Model Designation System Requirements MNC11 -0 Input Power (V) 115 Frequency (Hz) 60 Cabinet I Power Controller (H961 0) MNC11Chassis (MNCBA) KD 11-NA (M7270) MSV 11 D (M8044) Dl V 11-J (M8043) IBV 11-A (M7954) BDV11-A (M8012) RlV11- (M8013) RlV11- (M8014) lAV11-lA 180 Printer VT105 Terminal lA36 RlO 1 Disk Drive -J -K -L 115 60 115 60 115 60 BB/BC D BB/BC D MA HE 2 MNC11-AD MNC11-AA MNC11-AM MNC11-DI MNC11-DO MNC11-KW MNC11-AG Cable Console Interface Software Kit (English) Blank Control Panel (BNCBl) Installation Kit (MNCIK) * User's options • • As required to fill MNCBA plus one extra 147 2 K DECLAB-11/MNC 33 31 28 19 13 7 6 5 4 3 2 --------------------------------------- - - - - - -- 25 22 16 10 1 N A ~ ::; OBUS CD INTERCONNECTIONS - - -- -- ------------------------------------ - - ; g SLOTS 10 THROUGH 31 DECLAB-MNC OPTION EXPANSION AREA (FRONT VIEW) DECLAB MODULE UTI LlZATION • REPLACE THESE OPTIONS WHEN NOT REOUI RED WITH MB659 GRANT CARD OR G7272 PDP-11 103 DECLAB Module Utilization NOTE DECLAB-MNC option expansion area Is to be used only for MNC-serles module add-ons. No Qbus add-ons should be installed In this expansion area. No backplane expansion of the MNC system Is possible. System-Level Diagnostics Two diagnostic chain files are contained on the RLO 1 diagnostic disk for system troubleshooting. The diagnostic chain MNC 11 A.CCC provides the required diagnostics for testing the CPU and related modules and MNCseries modules. This program does not test the BDV 11 or VT 105 options. The contents of file MNC11A.CCC are as follows. R VMNF??I 1 R VKAA??I 1 R VKAB??I 1 R VKAC??I 1 R VKAL??I 1 MINC-11 option sizer program CPU test Extended instruction test Floating point instruction set test Traps test 148 DECLAB-11/MNC R VIBB??I 1 R VDLA?? 11 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R ZVTN??I 1 R VMNG??I 1 IBV11 test DLV11-J test Clock test MNCDI test MNCOO (digital out) diagnostic AID test VT105 test Terminator program The second diagnostic chain MNC11.CCC provides the required diagnostics for performing a quick check of the MNC-series modules only. The contents of file MNC 11.CCC are as follows. R VMNF??I 1 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R VMNG??I 1 Start-up I sizer program Floating point instruction set test MNCDI test MNCDO test DI A test AI D test Termination program Both programs are stored on the MNC diagnostic disk, Software Distribution Center (SDC) kit no. AX-E380EMC. Modules in the Basic System MNC11-AA (115 V, 60 Hz) and MNC11-AB (230 V, 50 Hz) Processor KD 11-NA (M7270) With Extended Instruction Set I Floating Point Instruction Set (KEV 11-A 23003B5). Jumper W 1 installed - crystal clock Jumper W3 removed - enable event line Jumper W6 installed - } Jumper W5 removed _ power-up to 173000 Memory - MSV11-DD (M8044) 64K byte MOS RAM without parity On-board memory refresh Jumper configuration 149 DECLAB-11/MNC Jumper Jumper State Pin 1 to 3 Pin 1 to 2 OUT IN Enable 2K 110 page option W2 IN Enable normal system power (+ 5 V) W3 IN Enable normal system power (+ 12 V) W4 OUT Disable battery power (+ 12 V) W5 OUT Disable battery power (+ 5 V) Pin 10 to 14 Pin 16 to 15 IN IN Select memory size of 64K bytes S 1 through S5 ON Starting address = bank 0 Function Implemented Serial Line Interface - DLV11-J (M8043) Number of serial lines: 4 Factory-set address and vector switches Device Address Vector Baud Rate Console SLU 2 SLU 1 SLU 0 777560 776520 776510 776500 300 1200 9600 60 320 310 300 9600/300· ·Varies depending on type of terminal. 150 OECLAB System Specifications 115 V, 50/60 Hz Power Connector Plug Receptacle Plug Receptacle NEMA No. 5-15P DEC No. 90-08938 5-15R 12-05351 NEMA No. 6-15P DEC No. 90-08853 6-15R 12-11204 VT105 LA36 OECLAB/ MNC System RL01 VT105 LA36 2.0 19 2.5 1.5 1.0 160 300 500 1200 150 200 150 160 300 OECLAB/ MINC System· RL01 Amperage Typical Maximum 19 3.5 Wattage Typical Maximum 500 1200 150 200 3.0 150 c Btu/Hour Typical Maximum Weight Kilograms Pounds 230 V, 50 Hz 550 1020 600 600 550 1020 m or- l> ...... DJ I 134 295 34.02 75 16.3 36 46.3 102 134 295 34.02 75 16.3 36 46.3 102 ........... i: z ·Includes MNCBA chassis with MNC-series module and two RLO 1 drives. o DECLAB-11/MNC CONSOLE MINe Terminal Distribution Panel 152 DECLAB-11/MNC Bus Terminator/Diagnostic/Bootstrap BDV11-A (M8012) Switch A (E15) RL01 Bootstrap A1 A2 A3 A4 A5 A6 A7 A8 ON ON OFF OFF OFF OFF ON OFF Switch B (E22) RL01 Bootstrap 81 82 83 84 85 OFF OFF OFF OFF ON IEEE Bus Interface - IBV11-A (M7954) (Optional) Address and vector switch settings: Address 171420 82-1,4 and 5 = ON only Vector 420 81-1 and 5 = ON only Disk Interface - RLV11 (M8014, M8013) Address and vector switch settings on M80 14 bus module: Address 174400 Vector 160 153 DECLAB-11/MNC MBO 14 Switch Setting Switch Position Function Bus Address (174400) ON ON OFF OFF ON OFF OFF OFF OFF OFF A 12 (MSB) A 11 A10 A09 Vector Switch OFF (160) OFF ON ON ON OFF OFF AOa A07 A06 A05 A04 A03 (LSB) va (MSB) V7 V6 V5 V4 V3 V2 (LSB) NOTE Additional MINC/DECLAB Information can be found in the following manuals. MINCIDECLAB Service Manual EK-MNC11-SV DECLAB-11IMNC User's Guide EK-MNC11-UG 154 11/23-BASED MINC PDP-11/23-BASED MINC/DECLAB-11 IMINC SYSTEMS MINC The Modular INstrumentation Computer (MINC) is a real time operating system featuring on-line data storage, and BASIC software with graphics, scientific, and laboratory subroutine packages. Each system consists of a MINC chassis, an RX02 dual floppy disk drive, and a VT105 terminal mounted on a roll-around cart. The MINC chassis houses a power supply, CPU and related modules, and up to eight MINC laboratory options. The physical components of a MINC system are grouped into two categories: items common to all MINC systems, and those that can be purchased as options, either when the system is first acquired or at some later time as add-ons. Each MINC system is configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the modules, specifications, and components. All PDP-11 123 MINC systems include the following standard items. MINC cart, which provides support and transport for: Dual diskette drive (RX02M) MINC chassis (MNCBA) with power supply (H786). This contains: KDF11-AB MSV11-DD RXV21 DLV11-J IBV11-A BDV11-A - LSI-11 processor with memory management EIS I FIS Memory (64K words) on two modules Diskette drive interface Four-channel serial ASCII interface IEEE bus interface Bus terminator I diagnostic Ibootstrap module. VT105 terminal with built-in graphics capability. MINC systems can include some or all of the following lab modules. Analog-to-digital converter (MNCAD) Preamplifier (MNCAG) Dual multiplexer (MNCAM) Clock (MNCKW) Digital-to-analog converter (MNCAA) Digital input unit (MNCDI) Digital output unit (MNCDO) 155 11/23-BASED MINe MINC systems can also include: Dot matrix printer (LA35) Isolation transformer (MNCIT) 110 baud, 20 rnA serial line interface (DLV11-KC). VT105 MASTER SYSTEM 11t---r-+---CI RCUIT BREAKER TERMINAL POWER SWITCH FUSE (3AG 3 A SLOW BLOW, 250 V) RX02 FLOPPY DISK MINC System 156 MNCIT (WHEN INSTALLED) 11/23-BASED MINe MINC System Model Designation System Requirements MNCFA -AA -BA Input Power (V) Frequency (Hz) 115 60 MNCFAChassis MNC BA KDF11-AB (M8186) MSV 11 D (M8044) RXV21 (M8029IBV 11-A (M7954) BDV11-A (M8012) MINC Cart RX02 VT105 LA35 -BC -BD -CA -CC -CD 115 60 1 AA 115 50 1 AA 230 50 115 60 1 AA/BA 115 60 1 AA/AC 115 50 1 MA MA 1 MC MA 1 MD MB 1 MA MA HE 1 MC MA HH 1 MC MB HS BID 1 2 MNCFA-AB MNCAD MNCAA MNCAM MNCDI MNCDO MNCKW MNCAG Cable Console Interface 1 Software Kit (English) Blank Control Panel (MNCBL) • User's options • • As required to fill MNCBA plus one extra QJV35-AX (RX02) diagnostic package supplied 157 11/23-BASED MINe IEEE BUS CONNECTOR (IBV11) CABLE CONSOLE INTERFACE 7015790-0-0 (3) LINE CORD DEC TO IEC 1700150-0 POWER LINE OUTLET INTERFACE 7015574-0 MINC System Cable Connections 158 - 33 31 28 25 19 22 16 13 10 8 6 5 4 3 2 1 ~ ~ N A <.:J <.:J '<t '<t <0 II: ~ en N '<t '<t <Xl 0 0 0 0 ~ <Xl <Xl <Xl OJ en en :2 L!) L!) :2 :2 :2 :2 :2 (') '<t 0 <Xl 0 <Xl :2 II: 0 <0 <Xl <0 <Xl :2 :2 OBUS - --- -- -- --- ----- ----- ----- ----- ----- ----- 0 II: -, 0 II: « « u u l- I- z z ~ ;;: « « ;;: > II: II: ....J 0 C1l CO <.:J <.:J ~ C « CD INTER· CONNECTIONS ~ ;;: 0 co D y SLOTS 10 THROUGH 31 MINC OPTION EXPANSION AREA (SEE MNC11· C SYSTEM) 'NOTE: MUST BE AT CS REVISION 'E' OR HIGHER. "NOTE: MUST BE AT CS REVISION 'E1' OR HIGHER. PDP-11 V23 MINC Module Configuration ~ a BUS OPTION EXPANSION AREA 0 0 (/) (/) 9 9 N ;;: ;;: X II: :2 :2 co ~ u.. 0 ~ ~ MINC System Specifications ~ .......... 115 V, 50/60 Hz N 230 V, 50 Hz ~ I Plug Receptacle Plug Receptacle aJ l> CIJ NEMA No. 5-15P DEC No. 90-08938 5-15R 12-05351 MINC Chassis' RX02 VT105 Amperage Typical Maximum 19 4.0 Wattage Typical Maximum 500 1200 460 Power Connector NEMA No. 6-15P DEC No. 90-08853 6-15R 12-11204 LA35 MINC Chassis RX02 VT105 2.0 8 2.0 3.0 LA35 1.5 1.0 0) o Btu/Hour Typical Maximum Weight Kilograms Pounds 250 300 225 16.3 36 160 300 460 550 1020 225 46.3 102 'Includes MNCBA chassis with MINC lab modules and RX02 and VT 105. 250 300 160 550 1020 16.3 36 46.3 102 m c 3: z o 11/23-BASED MINe NOTE MINe option expansion area Is to be used only for MINe lab module add-ons. No Qbus add-ons should be inserted in this expansion area. No backplane expansion of the MINe system is possible. All Qbus add-ons must be Inserted in either slot 5 or 6 (A and B only for double-height options). System-Level Diagnostics Two diagnostic chain files are contained on the diagnostic floppy for system troubleshooting. The diagnostic chain MNC 11 F .CCC provides the required diagnostics for testing the CPU and related modules including the BDV11, the VT105 option, and MINC lab modules. This chain requires turnaround connectors on SLUs 0, 1, and 2. For detailed operational information, refer to Book 7 of Working with MINe Devices, AA-D572A-TC. The contents of file MNC11F.CCC are as follows. R VMNF??I 1 R JKDA?? 11 R JKDB??I 1 R JKDC??I 1 R JKDD??I 1 R VIBB??I 1 R VDLA?? 11 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R ZVTN??I 1 R VMNG??I 1 MINC-11 option sizer program CPU test Extended instruction test Floating point instruction set test Traps test IBV11 test DLV11-J test Clock test MNCDI test MNCOO (digital out) diagnostic DI A test AID test VT105 test Termination program The second diagnostic chain MNCFA.CCC provides the required diagnostics for performing a quick check of the MINC lab modules only. The contents of file MNCFA.CC are listed below. R VMNF??I 1 R VMNC??I 1 R VMNB??I 1 R VMNE??I 1 R VMND??I 1 R VMNA??I 1 R VMNG??I 1 Start-up I sizer program Floating point instruction set test MNCDI test MNCDO test DI A test AID test Termination program Both programs are stored on the MINC diagnostic disk, available from the Software Distribution Center (SDC). Kit No. QJV35 - RZ (hard-copy documents) QJV35 - AX (RX02 floppy) ZJ281 - RX (hard-copy / RX02 floppy kit) 161 11/23-BASED MINe Modules in the Basic System MNC11F-AA (115 V, 60 Hz) and MNC11F-AB (230 V, 50 Hz) Processor (KDF11-AB) M8186 With warm floating pOint instruction set (KEF 11-A) and memory management. Jumper W 1 installed Jumper W4 removed Jumper W5 removed Jumper W6 installed Jumper W7 removed Jumper wa installed - crystal clock - enable event line = } power-up to 773000 (BDV 11) - enter console ODT on HALT - power-up with PC at 173000a (bootstrap) Memory - MSV11-DD (M8044-D) 64K bytes MaS RAM without parity On-board memory refresh Jumper configuration Jumper Jumper State Pin 1 to 3 Pin 1 to 2 IN } OUT Disable memory I/O page options W2 IN Enable normal system power (+ 5 V) W3 IN Enable normal system power (+ 12 V) W4 OUT Disable battery power (+ 12 V) W5 OUT Disable battery power (+ 5 V) Pin 10 to 14 Pin 16 to 15 IN IN } Select memory size of 64K bytes Function Implemented 162 11/23-BASED MINe MSV11-DDSwitch Settings Position 1st Module Switch Bank 0-7 Position 2nd Module Bank 10-17 Position 3rd Module Bank 20-27 Position 4th Module Bank 30-37 8-1 ON ON OFF OFF 8-2 ON OFF ON OFF 8-3 ON ON ON ON 8-4 ON ON ON ON 8-5 ON ON ON ON Serial Line Interface - DLV11-J (M8043) Must be at C8 revision "E" or higher. Number of serial lines: 4 Factory-set address and vector switches Device Address Vector Baud Rate Console 8LU 2 8LU 1 8LU 0 777560 776520 776510 776500 60 320 310 300 9600 300 1200 9600 163 11/23-BASED MINe CONSOLE MINe Terminal Distribution Panel 164 11/23-BASED MINe Bus Terminator/Diagnostic/Bootstrap BDV11-A (M8012) Diagnostic/bootstrap conditions are factory-selected using switch packs. Switch A (E15) RX02 Bootstrap A1 A2 A3 A4 A5 A6 A7 A8 ON ON OFF OFF OFF ON OFF OFF Switch B (E21) RX02 Bootstrap 81 82 83 84 85 OFF OFF OFF OFF ON Floppy Disk Interface - RXV21 (M8029) A12 I 1 Wll All Al0 A9 A8 A7 A6 A5 A4 I I I I I I I I I A3 1 1 1 0 0 1 1 1 1 Wl0 W9 W8 W7 W6 W5 W4 W3 W2 V8 V7 V6 V5 V4 V3 V2 I I I I I I I I 0 1 0 1 1 0 1 W18 W17 W16 W15 W14 W13 W12 1= JUMPER IN 0= JUMPER OUT RXV21 Address and Switch Settings 165 I I DEVICE ADDRESS 77717X VECTOR 264 DECLAB-11/MNC 11/23 DECLAB-11/MNC PDP-11 123-BASED SYSTEM The DECLAB-11 / MNC is a real time operating system featuring on-line data storage, and FORTRAN software with graphics, scientific, and laboratory subroutine packages. Each system contains as its main components, an MNC chassis, dual RL01 disk drives, and a terminal (VT105 or LA36). The MNC chassis houses a power supply, CPU, and related modules, and up to eight MNC- series option. The physical components of the DECLAB system are grouped into two categories: items common to all MNC systems, and those that can be purchased as options, either when the system is first acquired or at some later time as add-ons. Each DECLAB system is configured to boot on power-up and halt on BREAK. The figures and tables that follow describe the modules, specifications, and components. All DECLAB systems include the following standard items. Mass storage device containing two RLO 1 disk drives MNC chassis (MNCBA) with power supply (H786). This contains: KDF11-AB - MSV11-DD RLV11 DLV11-J IBV11-A BDV11-A - LSI-11 processor with memory management, floating pOint (KEF 11-A) Memory (128K byte: two modules) Controller (disk) Four-channel serial ASCII interface IEEE bus interface (optional) Bus terminator / diagnostic / bootstrap module. VT105 terminal with built-in graphics capability DECLAB systems can include some or all of the following lab modules. Analog-to-digital converter (MNCAD) Preamplifier (MNCAG) Dual multiplexer (MNCAM) Clock (MNCKW) Digital-to-analog converter (MNCAA) Digital input unit (MNCDI) Digital output unit (MNCDO) DECLAB systems can also include: Dot matrix printer (LAV 11 + LA 180 or LA35) 110 baud, 20 rnA serial line interface (DLV11-KC). 166 DECLAB-11/MNC 11/23 MNC CHASSIS ~~~!--0'\ r,::"-; ~ --~ ~_~---r - ~~~~~~ IIII I: II I, I I' I 1.-;,:/~~,~-=_~~-----J L. EXPANSION I: II CABINET (H9612) I c::::J ' I DISK DRIVE l:-__ - - ---J UNIT 0 [:] II I II II 11--- ~ I DISK DRIVE UNIT 1 ll __ ~ --- MASS STORAGE DEVICE CABINET H9610 VIDEO DISPLAY TERMINAL DECLAB-11 / MNC System with Optional Units 12 A 115 VAC 50/60 HZ FAST BLOW FUSE 10 A ACINPUT CABLE FROM VT100 OR VT105 115/230 VAC INPUT VT105 OR LA36/LA38 CONSOLE CABLE CABLE FROM RLV11.SLOT3 AC POWER CABLE TO MNCBA CHASSIS DO[§] DD~ MAX AC OUT 3A@230V 6A@115 V D DECLAB-11 / MNC Cable Connections 167 DECLAB-11/MNC 11/23 DECLAB-11/MNC System Model Designation System Requirements MNCFA -K -J Input Power (V) Frequency (Hz) Cabinet I Power Controller (H961 0) MNC11Chassis (MNCBA) KDF 11-AB (M8186) MSV11D (M8044) Dl V 11-J (M8043) IBV11-A (M7954) BDV11-A (M8012) RlV11- (M8013) RLV 11- (M80 14) 115 60 BB/BC D 115 60 BB/BC D 1 2 1 1 2 1 lAV 11-lA 180 Printer VT105 Terminal lA36 RlO 1 Disk Drive QJV35-AR Diagnostic Package (RlO 1) MNC11-F-AD MNC11-F-AA MNC11-F-AM MNC11-F-DI MNC11-F-DO MNC11-F-KW MNC11-F-AG Cable Console Interface Software Kit (English) Blank Control Panel (BNCBl) Installation Kit (MNCIK) • User's options • • As required to fill MNCFA 168 MA HE 2 1 2 1 DECLAB-11/MNC 11/23 33 2B 31 25 22 19 16 13 10 9 13 7 6 5 4 3' 2 1 N A g ::;; OBUS - ------------------------------------- -- - -- --- « CD INTER· ~ CONNECTIONS:; - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~ • NOTE: MUST BE AT CS REVISION 'E' OR HIGHER SLOTS 10 THROUGH 31 DECLAB·MNC OPTION EXPANSION AREA (FRONT VIEW) DECLAB MODULE UTILIZATION •• REPLACE THESE OPTIONS WHEN NOT REOUI RED WITH MB659 GRANT CARD OR G7272 . PDP-11 123 DECLAB Module Configuration NOTE DECLAB-11/MNC option expansion area Is to be used only for MNC-serles module add-ons. No Qbus add-ons should be installed in this expansion area. No backplane expansion of the MNC system is possible. System-Level Diagnostics Two diagnostic chain files are contained on the RLO 1 diagnostic disk for system troubleshooting. The diagnostic chain MNC11F.CCC provides the required diagnostics for testing the CPU and related modules and MNCseries modules. This program does not test the BDV 11 or VT 105 options. This chain requires turnaround connectors on SLUs 0, 1, and 2. For detailed operational information, refer to Book 7 of Working with MINe Devices, AA-D572A-TC. The contents of file MNC11F.CCC are as follows. R VMNF??I 1 R JKDA??I 1 R JKDB??I 1 MINC-11 option sizer program CPU test Extended instruction set 169 DECLAB-11/MNC 11/23 R JKDC??/1 R JKDD??/1 R VIBB??/1 R VDLA??/1 R VMNC??/1 R VMNB??/1 R VMNE??/1 R VMND??/1 R VMNA??/1 R ZVTN??/1 R VMNG??/1 Floating point instruction set test Traps test IBV11 test DLV11-J test Clock test MNCDI test MNCDO test (digital out) 01 A test AID test VT105 test Termination program The second diagnostic chain MNC11F.CCC provides the required diagnostics for performing a quick check of the MNC-series modules only. The contents of file MNC 11 F .CCC are as follows. Start-up I sizer program Floating point instruction set test MNCDI test MNCDO test 01 A test AID test Termination program R VMNF??/1 R VMNC??/1 R VMNB??/1 R VMNE??/1 R VMND??/1 R VMNA??/1 R VMNG??/1 Both programs are stored on the MNC diagnostic disk, Software Distribution Center (SOC) kit no. BA-FO 18· -MC. LOCAL POWER POWER CONTROLLER PLUG RECEPTACLE 871-B 230V 10A 50/60HZ -~ @ NEMA # 6-15P DEC # 90-08853 6-15R 12-11204 == 871-C 115V 20A 50/60HZ © -. HUBBELL # 5366-C DEC # 12-15183 @ o IP NEMA# 5-20R 12-12265 MR-5383 DECLAB/MINC and MINC RL01 Add-On Power Requirements 170 Specifications 115 V, 50/60 Hz Power Connector 230 V, 50 Hz Plug Receptacle Plug Receptacle NEMA No. 5-15P DEC No. 90-089 38 5-15R 12-05351 NEMA No. 6-15P DEC No. 90-08853 6-15R 12-11204 VT105 DECLAB/ MNC System VT105 DECLAB/ MINC System· RL01 Amperage Typical Maximum 19 3.5 Wattage Typical Maximum 500 1200 150 200 LA36 RL01 3.0 250 300 LA36 1.5 2.0 2.5 160 300 150 200 1.0 250 300 160 300 C m or l> m Btu/Hour Typical Maximum 600 550 1-020 600 550 1020 I ~ ~ '- 3: Weight Kilograms Pounds 134 295 34.02 75 16.3 36 46.3 102 134 295 • Includes MNCBA chassis with MNC-series module and two RLO 1 drives. 34.02 75 16.3 36 46.3 102 z o DECLAB-11/MNC 11/23 Modules Included in the Basic PDP-11 123 System MNC11F-AA (115 V, 60 Hz) and MNC11F-AB (230 V, 50 Hz) Processor (KDF11-AB) M8186 With warm floating point instruction set (KEF 11-A) and memory management. Jumper W 1 installed Jumper W4 removed Jumper W5 removed Jumper W6 installed Jumper W7 removed Jumper W8 installed - crystal clock - enable event line = } power-up to 773000 (BDV 11) - enter console ODT on HALT - power-up with PC at 1730008 (bootstrap) Memory - MSV11-DD (M8044) 64K byte MaS RAM (without parity) On-board memory refresh Jumper configuration Jumper Jumper State Function Implemented Pin 1 to 3 Pin 1 to 2 IN } OUT Disable memory I/O page option W2 IN Enable normal system power (+ 5 V) W3 IN Enable normal system power (+ 12 V) W4 OUT Disable battery power (+ 12 V) W5 OUT Disable battery power (+ 5 V) Pin 10 to 14 Pin 16 to 15 IN IN } Select memory size of 64K bytes 172 DECLAB-11/MNC 11/23 MSV11-DD Switch Settings Position 1st Module Switch Bank 0-7 Position 2nd Module Bank 10-17 Position 3rd Module Bank 20-27 Position 4th Module Bank 30-37 8-1 ON ON OFF OFF 8-2 ON OFF ON OFF 8-3 ON ON ON ON 8-4 ON ON ON ON 8-5 ON ON ON ON Serla! Line Interface - DLV11-J (M8043) Must be at C8 revision "E" or higher. Number of serial lines: 4 Factory-set address and vector switches Device Address Vector Baud Rate Console 8LU 2 8LU 1 8LUO 777560 776520 776510 776500 60 320 310 300 9600 300 1200 9600 173 DECLAB-11/MNC 11/23 CONSOLE MINe Terminal Distribution Panel Bus Terminator/Diagnostic/Bootstrap BDV11-A (M8012) Diagnostic I bootstrap conditions are factory-selected using switch packs. RL01 Bootstrap ON ON OFF OFF OFF OFF OFF ON OFF Switch A (E15) A1 A2 A3 A4 A5 A6 A7 A7 A8 174 DECLAB-11/MNC 11/23 Switch B (E21) Rl01 Bootstrap B1 B2 B3 B4 B5 OFF OFF OFF OFF ON IEEE Bus Interface - IBV11-A (M7954) optional Address and vector switch settings: Address 171420 S2-1, 4 and 5 = ON only Vector 420 S-1 and 5 = ON only Disk Interface - RlV11 (M8013, M8014) Address and vector switch settings as shown in the following. M8014 Switch Settings Switch Position Function Bus Address (174400) ON ON OFF OFF ON OFF OFF OFF OFF OFF A 12 (MSB) A 11 A10 A09 Vector Switch OFF (160) OFF ON ON ON OFF OFF 175 AOa A07 A06 A05 A04 A03 (lSB) va (MSB) V7 V6 V5 V4 V3 V2 (lSB) CPU/OPTIONS GENERAL MODULE INFORMATION GENERAL MODULE INFORMATION This section lists LSI-11 modules alphanumerically by module number. The tables below list modules by option designation for cross-referencing. All modules are (or will be) covered in Microcomputer Processor Handbook, EB-20175-20, (CPUs and memories) or the Minicomputer Interfaces Handbook, EB-18451-20. The following conventions are used in presenting module data. Registers The base address is listed first. This is normally the address of a control status register. Abbreviations containing "CS" or "CSR" are for control status registers. Abbreviations containing "DB," "DBR," or "BUF" refer to data buffer registers. Switches Switches are labeled "S 1, S2, S3, ... " although they may be located in the same DIP switch pack. Rocker switch states are selected by pressing the side closest to the label of the state desired. For example, to select the ON position, press the side of the rocker closest to the edge of the switch on which "ON" is printed; disregard the red line on the end of the rocker. Jumpers "I" indicates that a jumper is inserted. "R" indicates that it is removed. "X" indicates a "don't care" condition. Location drawings show jumpers installed, for clarity, although they may not actually be installed for the standard configuration. Tables define the jumper states. Jumpers are shown as a solid line if they are normally installed. NOTE Jumpers are not always installed for a 1 and removed for a 0; on some modules the reverse is true. See Appendix A for XXDP + diagnostic names, functions, and multimedia assignments. 179 A012 A012 ADV11-A ANALOG-TO-DIGITAL CONVERTER Amps +5 2.0 Bus Loads +12 0.45 AC 3.25 DC 1 Cables BC04Z BC04R BCV11 BC08R used with H322 Standard Addresses CSR DBR 170400 170402 Vectors AID Done Error 400 404 Diagnostic Programs Refer to Appendix A. NOTE CVADA?? and CXADC?? tests require wraparound connector PN 70-12894. Related Documentation ADV11-A, KWV11-A AAV11-A, DRV11 User's Manual (EK-ADV 11-0P) Field Maintenance Print Set (MPOO 193) Microcomputer Interfaces Handbook (EB-20 175-20) 180 SI NGLE-ENDED JUMPER LUGS ADDRESS BIT 2 SWITCHES c~_~~noo OFFSET-./ ADJ '- S2 W3 ](/) BIT 11 pWcrU BIT3 VECTOR BITS SW ITCHES S C 0 TAB C (CLOCK OVERFLOW IN) TAB S (EXTERNAL START) ~~~N co 11-4322 A012 Jumper W3 is inserted for single-ended operation, and removed for quasidifferential operation. 15 14 13 12 11 09 08 07 06 05 04 03 02 01 00 02 01 00 I I I I I I STANDARD VECTOR CONFIGURATION (400) 10 ON VECTOR SWITCH (:il) OFF OFF OFF OFF OFF I t t t ttl 1 8 ....... _____________ CSR ADDRESS FORMAT 15 14 13 12 11 10 09 08 07 06 05 04 03 111111111010101110101010101010101 I I I I I I I I I I STANDARD ADDRESS CONFIGURATION OFF OFF OFF (170400) ON OFF OFF OFF OFF OFF OFF + + + + ! ! ! ! ! ! 11 10 CSR ADDRESS SWITCH (S2) • ERR INT ENA 1 . AD DONE elK START ENA ID ENA ADV 11-A Control/Status Register (CSR) 182 NOT USED A012 CSR Bit Definition Bit Function 15 A/D Error (read/write) - The A/D Error may be program set or cleared and is cleared by the processor initialize. It is set by any of the following: a. attempting an external or clock start during the transition interval b. attempting any start during a conversion in progress c. failing to read the result of a previous conversion before the end of the current conversion. 14 Error Interrupt Enable (read/write) - When set, enables a program interrupt upon an error condition (A/D Error). Interrupt is generated whenever bits 14 and 15 are set, regardless of which was set first. 13-12 Not used. 11-8 Multiplexer Address (read/write) - Contain the number of the current analog input channel being addressed. 07 A/D Done (read) - Set at the completion of a conversion when the data buffer is updated. Cleared when the data buffer is read, and by the processor initialize. If enabled interrupts are requested simultaneously by bits 07 and 15, bit 07 has the higher priority. 06 Done Interrupt Enable (read/write) - When set, enables a program interrupt at the completion of a conversion (A/D Done). Interrupt is generated when bit 07 and bit 06 are both set, regardless of sequence. 05 Clock Start Enable (read/write) - When set, enables conversions to be initiated by an overflow from the clock option. 04 External Start Enable (read/write) - When set, enables conversions to be initiated by an external signal or through a Schmitt trigger from the clock option. 03 10 Enable (read/write) - When set, causes bit 12 of the data buffer register to be loaded to a 1 at the end of any conversion. 183 A012 CSR Bit Definition (Cont) Bit Function 02 Maintenance (read/write) - Loads, when set, all bits of the converted data output equal to multiplexer address LSB (bit 08) at the completion of the next conversion. Cleared by the processor initialize. Used for "all Os" and "all 1s" tests of A/D conversion logic. 01 Not used. 00 A/D Start (read/write) - Initiates a conversion when set. Cleared at the completion of the conversion and by the processor initialize. . VERNIER DIA (WRITE) I" " "I" I I "I I . I I . I I . I I . I I . I • MSB 15 W ~~M~S~B 0' 0' 0' 0' 0' " LSB 01 00 02 __________________~.__________________~LS~B. ID CONVERTED DATA (READ) ADV 11-A Data Buffer Register (DBR) DBR Bit Definition The DBR is actually two separate registers: one read only, the other, write only. Bit Function Read Only (Cleared at processor initialize.) 15-13 Not used. Should read as O. 12 ID (read) - When ID Enable (bit 03) of the CSR has been set, BDR bit 12 will be loaded to a 1 at the end of conversion. 11-00 Converted Data (read) - These bits contain the results of the last A/D conversion. Write Only (Set to 200 at processor initialize.) 15-08 Not used. 07 -00 Vernier D/ A (write) - These bits provide a programmed offset to the converted value (scaled 1 D/ A LSB = 1/50 A/D LSB). The hardware initializes this value to 200 (mid-range). Values greater than 200 make the input voltage appear more positive. 184 A6001 A6001 AAV11-A DIGITAL-TO-ANALOG CONVERTER Amps +5 1.5 Bus Loads -12 AC 0.4 1.91 Cables DC BC04Z BC04R BC11V BC08R used with H322 Standard Addresses DAC1 DAC2 DAC3 DAC4 170440 170442 170444 170446 Vectors None. The AAV-11 does not cause interrupts. Diagnostic Programs Refer to Appendix A. Related Documentation ADV11-A, KWV11-A, AAV 11-A, DRV11 User's Manual (EK-ADV 11-0P) Field Maintenance Print Set (MPOO 186) Microcomputer Interfaces Handbook (EB-20 175-20) 185 » 0) o c Jl 1 DO DO DODD ~34 ~5 Rf (GAIN) (OFFSET) Ris (GAIN)(GAIN) DAC 1 DAC 2 II ~ ~~ ~ 0---0 0---<1 0---<1 WG W4 we W9 II i\ \37 (GAIN) (OFFSET~R49 (OFFSET) ~~ II .,..........,.,.........., W13 o o ..... DAC3 DAC 1 Ri (OFFFET) DAC 0 DAC2 DAC0 W14 DAC 3 ~~ -W17 WIG MODE / LEVEL STRAPS co m BIT 11 BIT 3 \ SI / Ir--~I (ADDRESS) 11-4319 AAV 11-A Address Switches (Set for 17044n) A6001 111 14 13 12 11 10 09 08 07 06 06 04 03 02 01 00 STANDARD ADDRESS CONFIGURATION (1704401 ~~~RESS SWITCH I. ~I 1_ 5 _9......'_8......'_7___'......6_... _.'_4-,,_3-,,'_2......'_1 LOGICAL 1 • ON LOGICAL O. OFF MA-0855 AAVll-A ADDRESS WORD " I " I "I" I 1 15 1. 1 1 • 0 10 09 0 o "0 • 0 : WORD OR LOW BYTE "0' 1 : HIGH BYTE 0' 1I I o . 1 0 " 2 "I 0 0 0 1 0 ADDRESS DAC MODE 170440 170441 170442 170443 170444 170445 170446 170447 0 0 WORD OR LOW BYTE HIGH BYTE WORD OR LOW BYTE HIGH BYTE WORD OR LOW BYTE HIGH BYTE WORD OR LOW BYTE HIGH BYTE 1 2 2 3 3 N "I 0 04 03 02 01 00 0" • "I o DAC 0 1 11-4313 AA V 11-A Address Decoding 187 A6001 Jumper Configurations for Bipolar Operation (as Shipped) ±2.56 V ±5.12 V ± 10.24 V DAC1 W3 W4 W5 W6 IN IN OUT OUT OUT OUT OUT IN IN DAC2 W7 W8 W9 W10 IN IN OUT OUT OUT OUT OUT IN IN DAC3 W11 W12 W13 W14 IN IN OUT OUT OUT OUT OUT IN IN DAC4 W15 W16 W17 W18 IN IN OUT OUT OUT OUT OUT IN IN IN IN IN IN IN IN IN IN 188 IN IN IN IN A6001 Jumper Configurations for Unipolar Operation o V - +5.12 V o V - + 10.24 V DAC1 W3 W4 W5 W6 IN OUT IN OUT IN OUT OUT OUT DAC2 W7 W8 W9 W10 IN OUT IN OUT IN OUT OUT OUT DAC3 W11 W12 W13 W14 IN OUT IN OUT IN OUT OUT OUT DAC4 W15 W16 W17 W18 IN OUT IN OUT IN OUT OUT OUT AAV11-A Input Code/Output Voltage Relationship Input Code Unipolar Bipolar 0000 4000 7777 0V 1/2 FS +FS - 1/2 LSB -FS 0V +FS - 1/2 LSB 189 BA 11-M BA11-M Mounting Box: Physical Specifications I a.9CM (3.5INI !-=================:::::::I~ 14-------~1';31~~---J 34.3 CM 14 - - - - - - - ( 1 3 . 5 I Nl-------.l-I 1 POWER SUPPLY AIR AIR } '--- FRONT PROCESSOR MEMORY AND DEVICES SA 11-M Assembly Unit 190 BA11-M Electrical (These specifications reflect the characteristics of the H780 power supply.) Input Voltage (Continuous: see Note 1.) 100 Vac-127 Vac (H780-C, -H, -K) 200 Vac-254 Vac (H780-D, -J, -L) Temporary Line Dips Allowed 100% of voltage, 20 ms max. AC Inrush Current 70 A at 127 V 60 Hz (8.33 ms) 25 A at 254 V 50 Hz (10 ms) Input Power (Fans Included) 340 W at full load max. 290 W at full load typical EMI (Emission and Susceptibility) Per DEC STD 102.7 and VDE N-12 limits Input Protection H780-C, -H, -K (100 Vac-127 Va c) fast blow, 5 A fuse H780-D, -J, -L (200 Vac-254 Vac) fast blow, 2.5 A fuse Hi-Pot 2 kV for 60 seconds from input to output, or input to chassis Output Power (Combinations not to exceed 110 W.) +5V, 1.5A- 18A + 12 V, 0.25 A - 3.5 A Maximum DC Current Under Fault Conditions +5 V bus = 28 A + 12 V buS = 9.5 A +5 V Output Total regulliltion Line regulation Load regulation Stability Thermal drift Ripple Dynamic load regulation 5 V ± 3% ±0.5% ± 1.0% 0.1 %/ 1000 hours 0.025%;0 C (See Note 2.) 150 mV p-p (1 % for f<3 kHz) ± 1.2% di/dt = 0.5 A/J.ls t:.L = 5 A 191 BA11-M Noise 1% peak at 5 > 100 kHz (noise is superimposed on rippl'e) Interaction due to + 12 V ± 0.05% + 12 V Output Total regulation Line regulation Load regulation Stability (See Note 2.) Ripple Dynamic load regulation 12 V ± 3% ±0.25% ±0.5% O. 1%/ 1000 hours 0.025%;0 C above 25 0 C 350 mV p-p (1 % for f <3 kHz) ±0.8% di/dt = 0.5 A/J.Ls f<500 Hz 6L = 3 A Noise 1% peak f > 100 kHz (Noise is superimposed on ripple.) Interaction due to + 5 V ±0.2% Overvoltage Protection +5V + 12 V Adjustments +5 V output + 12 V output Controls Rear panel 6.3 V nominal 5.65 V min. 6.8 V max. 15 V nominal 13.6 V min. 16.5 V max. 4.05 V-6.8 V Guarantee range 4.55 V -5.65 V 10.6 V-16.5 V Guarantee range 11.7 V -13.6 V AC ON/OFF switch Front console DC ON/OFF switch HALT/ENABLE switch (Master only) LTC ON/OFF switch 192 BA 11-M Console Indicators DC ON RUN (master) SPARE (master only) Backplane Signals BPOK H } BDCOK H Transmitted BEVNT L BHALT L SRUN L Received (master only) Mechanical Cooling Two self-contained fans provide 0.7140 m 3 /min (30 ft 3 /min) air flow. Size 13.97 cm w X 8.43 cm h X 37.15 cm I (5-1/2 in w X 3-1/3 in h X 14-5/8 in I) Weight 5.90 kg (13 Ib) Environmental Temperature Ambient Storage 5°-50° C (41°-122° F) -40°-70° C (-40°-158° F) Humidity 90% maximum without condensation NOTES 1. Operation from ac lines below 100 V may cause the power supply to overheat because of decreased air flow from the cooling fans. 2. Thermal drift parameters apply after five minutes of warmup and are measured with an averaging meter at the processor backplane terminal block under system loading. 193 BA 11-M Option Variations BA 11-MA Consists of a BA 11-MC mounting box with H9270-A backplane and H780A power supply for 115 Vac, 60 Hz. BA 11-MB Consists of BA 11-MC mounting box with H9270-A backplane and H780-B power supply for 230 Vac, 50 Hz. BA 11-MC Consists of 3.5 inch high mounting box with no backplane or power supply. BA 11-ME Consists of BA 11-MC mounting box with H9270-A backplane and H780-E power supply for 115 Vac, 60 Hz. BA 11-MF Consists of BA 11-MC mounting box with H9270-A backplane and H780-F power supply for 230 Vac, 50 Hz. Power Supply Models 115 Vac H780-A H780-B H780-C H780-D H780-E H780-F H780-H H780-J H780-K H780-L H780-M H780-N H780-P H780-R 230 Vac Line Cord Console Fans Type X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 194 Master Master None None Slave Slave Master Master Slave Slave Note 1 Note 1 Note 2 Note 2 BA 11-M NOTES 1. The H780-M and -N have no control panel on the basic option. The Business Products 320 line uses a control panel that has two DC ON indicators (PN 54-12695). This control panel is carried as part of the 11 /03-J computer. 2. The H780-P and -R also use the 54-12695 control panel. They differ from the -M and -N in that the basic power supply option includes the control panel, a line cord, and fans. 3. The 115 Vac options operate on 100 Vac-127 Vac at either 50 or 60 Hz. The 230 Vac options operate on 200 Vac-254 Vac at either 50 or 60 Hz. Power Supply/Control Panel Interface Cables Cable DECPN DC output cable Power supply status cable (logic cable) Power supply console cable 7011584-0-0 7011411-0K-0 7008612-0M-0 BLACK WHITE GREEN 1-= } 115 VAC CHASSIS GROUND TERMINAL BLOCK (TB1) 115 Vac Terminal Block Wiring BROWN BLUE } GREENIYELLOW 1 CHASSIS -= GROUND TERMINAL BLOCK (TB1) 230 Vac Terminal Block Wiring 195 230 VAC BA11-M Cable Interconnections J4 12-PIN CONNECTOR (SIDE 2 OF PC BOARD) H780 POWER SUPPLY AC LINE CORD '- B CONSOLE SIGNAL/POWER CABLE (11 in.) I--~-+-+-.---......-r-r-_--J (70-08612- OM-O) 1 2 SIGNAL CABLE (10 in.) ( 70-11411-0K-0) 3 4 5 6 7 B 9 10 BPOK H BEVNT L SRUN L (KEY) GROUND CL3 L CS3 L SPARE BHALT L DCOK H I 2 3 4 5 6 7 8 SIGNAL .!:!..!'!. +5A DC ON H SRUN L 9 +5A 10 SPARE II SPARE 12 GROUND 13 GROUND 14 DC OK LED H 15 SPARE 16 B HALT L iiEVNT[ GROUND CL3 CS3 SPARE SIGNAL CONNECTOR PINS ON H9270 P.C. BOARD '0 _BDCOK H L~~:::LTL H9270 BACK PLANE REAR V I EW (P.C. BOARO SlOE 2) ""'~SRUN L STRIP +5VB BPOK H TERMINAL BLOCK H780 to H9270 Backplane Connections Master jSlave Interface Cables Length 10_2 em 15_0 em 22.9 em 27_5 em 35_6 em 45.7 em 124.0 em 61.0 em 1.83 m 3.05 m 4.88 m DEC PN (4 in) (6 in) (9 in) (11 in) (14 in) (18 in) (49 in) (2 ft) (6 ft) (10ft) (16 ft) 7008612-00 7008612-0F 7008612-0K 7008612-0M 7008612-1B 7008612-1 F 7008612-4A 7008612-02 7008612-6A 7008612-10 BC034-16* * Refer to the "Systems Configurations" section for applications using this cable. 196 BA11-M + 12 V Adjustment Perform the following procedure when adjusting the + 12 Vdc output. 1. Apply power to the LSI-11 or PDP-11 /03 system and allow a five minute warm-up period. 2. Using a DVM, measure the + 12 V output at the LSI-11 or PDP-11/03 backplane terminal block. 3. Using a small screwdriver, adjust RB7 until the DVM indicates + 12.0 V (+ 11.64 V to + 12.36 V acceptable range). Turning RB7 CW (clockwise) decreases the + 12 V output, while turning CCW (counterclockwise) increases the output. NOTE If R87 is turned too far CCW, the + 12 V output will crowbar and drop to approximately 0 V. This will occur between + 13.0 V and + 16.5 V. Do not allow the supply to crowbar as this may blow the internal fuse (F 1) protecting the + 12 V regulator. 4. Using an oscilloscope, measure the ripple on the + 12 V output at the backplane terminal block. The ripple should not be greater than 350 mV peak-to-peak. + 5 V Adjustment Perform the following procedure when adjusting the + 5 Vdc output. 1. Apply power to the LSI-11 or PDP-11 /03 system and allow a five minute warm-up period. 2. Using a DVM, measure the + 5 V output at the LSI-11 or PDP-11 /03 backplane terminal block. 3. Using a small screwdriver, adjust RBB until the DVM indicates + 5.0 V (+ 4.B5 V to + 5.15 V acceptable range). Turning RBB CW decreases the + 5 V output, while turning CCW increases the output. NOTE If R88 is turned too far CCW, the + 5 output will crowbar and drop to approximately 0 V. This will occur between +5.6 Vand + 6.8 V. Do not allow the supply to crowbar as this may blow the internal fuse (F2) protecting the +5 V regulator. 4. Using an oscilloscope, measure the amplitude and frequency of the ripple on the + 5 V output at the backplane terminal block. The ripple should not be greater than 150 mV peak-to-peak with a period from BO I1s-140 I1S. If the ripple period is not within BO I1S-140 I1S, adjust R96. Turning R96 CW decreases the ripple period, while turning CCW increases the period. After adjusting the ripple period, recheck the + 5 V output (steps 2 and 3). 197 BA11-M MEASURE HERE H9270 BACKPLANE REAR V I EW (P.C. BOARD SIDE 2) TERMINAL BLOCK MR-076& Backplane Terminal Block +12 V OUTPUT ACAJUST (RS7) CCItJ - INCREASE CW - DECREASE 0 I +5 V FREQUENCY ADJUST (R69) CCW - INCREASE CW - DECREASE I @ +5 V OUTPUT ADJUST (RSS) CCW - INCREASE CW DECREASE L r @ HEAT SINK FAN FAN L Locations of H780 Adjustments 198 SA 11-M Controls and Indicators BA 11-M/H780 Controls and Indicators Control! Indicator Type Function DC ON LED Indicator Illuminates when the DC ON/OFF toggle switch is set to ON and proper dc output voltages are being produced by the H780. + + If either the 5 or 12 V output from the H780 is faulty, the DC ON indicator will not illuminate. This is the only indicator on the H780-K and -L slave supplies. RUN LED Indicator Illuminates when the processor is in the run state (see ENABLE/HALT). SPARE LED Indicator Not used by the H780 or processor. The H780 contains circuitry for driving this indicator for user applications. DC ON/OFF Two-Position Toggle Switch When set to ON, enables the dc outputs of the H780. The DC ON indicator will illuminate if the H780 dc output voltages are of proper values. If a slave supply is connected to a master, the slave DC ON indicator will light if the slave dc output voltages are of proper value. When set to OFF, the dc outputs from the H780 are disabled and the DC ON indicator is extinguished. If a slave supply is connected to a master, the slave DC ON indicator will also extinguish. ENABLE/HAL T Two-Position Toggle Switch When set to ENABLE, the BHAL T L line from the H780 to the processor is not asserted and the processor is in the run mode (RUN indicator illuminated). 199 BA 11-M BA 11-M/H780 Controls and Indicators (Cont) Control! Indicator Type Function ENABLE/HAL T Two-Position Toggle Switch When set to HALT, the BHAL T L line is asserted, allowing the processor to execute console OOT microcode (RUN indicator extinguished). LTC ON/OFF Switch Two-Position Generation When set to ON, enables the toggle of the line time clock (LTC) BEVNT L signal by the H780. When set to OFF, disables the H780 line time clock. AC ON/OFF (Rear Panel) Two-Position Toggle Switch When set to ON, applies ac power to the H780. When set to OFF, removes ac power from the H780. FUSE (Rear Panel) 5 A or 2.5 A Fast Blow Protects H780 from excessive current. H780-C, -H, and -K use a 5 A fuse. H780-0, -J, and -L use a 2.5 A fuse. ROWS A o C PROCESSOR (HIGHEST PRIORITY LOCATION) PROCESSOR OR OPTION 1 OPTION 3 OPTION 2 OPTION 4 OPTION 5 OPTION 7 (LOWEST PRIORITY LOCATION) OPTION 6 SLOTS VIEW FROM MODULE SIDE OF BACKPLANE H9270 Option Positions 200 4 BAll-M J2 Jl ,-... 14 ~ 14 0 C DCON H 2 C DCON H 16 0 0 3 3 0 0 B 1 +5A 9 0 Gi D L 1 TP4"" 9 TPI .n. --0 5 13 CL3 13 6 CS3 6 7 4 4 r PIN 1 = CUT ETCH CON· ~1l~I~~;~~~ _~1 00 CUT IT SUCH THAT THE GAP CAN BE EASI L Y ~~P~l~oW~~~ 0 STORE THE GROUND PATH. Cl 01 .rlI ~ C SPARE 3 TP 10 C SPARE 4 11 12 C SPARE 5 12 15 C SPARE 6 15 11 TP3' W2 (ETCH CUT) 0 10 01 DC Q B C SPARE 1 0 5 r, q>~ 2 16 THIS ETCH CU T IS MADE WHEN THE BALL·M IS USED AS AN EXPAN DER BOX ON 11 03-L SYSTE MS. (BALL·N AND BOVIll ~ '-' -= H780 Slave Console Modification H780 Slave Console Modification The slave console (54-12143) for the H780 (in the SA 11-ME/F 3.5 inch PDP-11/03 expander box) contains an etch that applies a ground signal to pin 4 (and others) on J 1. This is desirable except when the SA 11-M is used as an expander box and contains a line clock, such as with the SDV 11 or when a SA 11-M is used to expand an PDP-11 /03-L system. In this case, the SDV 11 requires the SEVNT signal to generate line clock interrupts. If this etch is present, the signal SEVNT L is asserted (reference H780 sheet 3 schematic), turning off the SEVNT signal. To correct this unwanted condition, it is necessary to cut an etch on the 54-12143 slave console board. This etch is made only for the reason described above. ECO no. 54-12143-PN002 has been written to document this change. In the ECO, the etch cut is referred to as W2. Pay particular attention to this when adding a SA 11-M as an expander box, or when replacing the power supply/slave console assembly (H780-E/F /K/L) or the slave console board. 201 BA11-N BA 11-N Mounting Box: Physical Specifications I...--I 57,BCm _ _ _-------l! (22,7 in) • AC INPUT PANEL "'C AIR AIR o ~ ::tI BACKPLANE ASSEMBLY en C "'C ~ -< BA 11-NE and BA 11-NF Assembly Unit 202 BA 11-N Power Supply Specifications Item Specification Current Rating 5.5 A at 115 Vrms 2.7 A at 230 Vrms Inrush Current 100 A peak for one-half cycle at 128 Vrms or 256 Vrms Apparent Power 630 VA Power Factor The ratio of input power to apparent power shall be greater than 0.6 at full load and low input voltage. Output Power +5 Vdc, ± 250 mV at 22 A. (A minimum of 2 A of +5 Vdc power must be drawn to ensure that the + 12 Vdc supply regulates properly.) + 12 Vdc, ±600 mV at 11 A. Power-Up/Power-Down Characteristics Static Performance Power-up BOCOK H goes high: 75 Vac BPOK H goes high: 90 Vac Power-down BPOK H goes low: 80 Vac BOCOK H goes low: 75 Vac Oynamic Performance Power-up 3 ms (min.) from dc power within specification or to BOCOK H asserted. 70 ms (min.) from BOCOK H asserted to BPOK H asserted. Power-down 4 ms (min.) from ac power off to BPOK H negated. 4 ms (min.) from BPOK H negated to BOCOK H negated. 5 microseconds (min.) from BOCOK H negated to dc power as of specifications. 203 SA 11-N Option Variations BA 11-NC Consists of 13.2 cm (5.2 inch) mounting box with metal cover, H9273 backplane, and H786 power supply with console, for 115 Vac, 60 Hz. BA 11-ND Consists of 13.2 cm (5.2 inch) mounting box with metal cover, H9273 backplane, and H786 power supply with console, for 230 Vac, 50 Hz. BA 11-NE Consists of 13.2 cm (5.2 inch) mounting box with metal cover, H9273 backplane, and H786 power supply without console, for 115 Vac, 60 Hz. BA 11-NE Consists of 13.2 cm (5.2 inch) mounting box with metal cover, H9273 backplane, and H786 power supply without console, for 230 Vac, 50 Hz. CONFIGURATION Jumpers and Switches Backplane Jumper Positions - There are three jumper positions on the H9273 backplane: W 1, W2, and W3. Jumpers are installed in all three positions when the backplane is manufactured. The conditions under which jumpers should be inserted or removed are described in the "Backplane Jumpers" table. The jumper in position W 1 is involved with CPU event interrupts. These interrupts can be initiated in two ways. First, a signal source external to the BA 11-N can be used to pull the LSI-11 bus BEVNT L line low; in this case, the jumper of W 1 of each H9273 backplane in the system would have to be removed. Second, the LTC signal generated in the H786 power supply can be used to pull the BEVNT L line low, thereby initiating vectored interrupts at a rate that depends on the BA 11-N line frequency. W 1 connects the LTC signal to the BEVNT L line; hence, in this case, the jumper would be left in position W 1 of the H9273 backplane. In a multiple-box system, the box containing the M8012 module (i.e., the last box in the system) must be the source of the LTC signal; thus, the W 1 jumper must be inserted in the backplane of this box and must be removed from the backplane of the other box(es). The jumper in W2 connects CK 1 to CL 1 in row 1, while the jumper in W3 connects DK 1 to DL 1, also in row 1. These jumpers must be inserted whenever a quad KD 11 CPU resides in row 1 of the first box. 204 SA 11-N All three of these jumpers can be inserted and removed without any need for disassembly, other than removing the logic box base from the cover. However, if it ever becomes necessary to have clear access to the backplane, follow the instructions given for removal of the logic assembly in the BA 11-N Mounting Box Technical Manual, EK-BA 11N-TM. Backplane Jumpers Jumper Position Jumper(s) In Jumper(s) Out W1 When the H786 power-supply generated LTC signal is used to assert the LSI-11 bus BEVNT L signal. When it is not desired to have line time clock (LTC) sourcing BEVNT L, such as when an external source is used instead. W2, W3 When a processor module (KD 11 or KDF 11) is inserted in row 1 of the backplane. When any other module is installed in row 1; that is, when the backplane is part of an expander box. NOTE In multiple backplane systems, only the one backplane can have jumper W1 installed. If a BDV11 module is used, install the jumper in the backplane containing the BDV11 module. 205 SA 11-N Backplane JUmpers 206 Bezel Assembly Jumper Positions - There are four jumper positions, W 1, W2, W3, and W4, on the printed circuit board of the bezel assembly. When the board is manufactured, jumpers are inserted in positions W 1, W2, and W4; position W3 is left blank. If it is necessary to remove the bezel assembly printed circuit board for any reason, follow the instructions for removal of the bezel assembly given in the BA ll-N Mounting Box Technical Manual, EK-BA11N-TM. Bezel Assembly Jumpers Jumper Position Jumper In Jumper Out W1, W2 When the bezel AUX ON/OFF switch is used to control the power-supplygenerated LTC signal. (When the switch is in the AUX ON position, L TC-initiated interrupts are possible). When the bezel AUX ON/OFF switch is used to turn the system power controller on and off. W3 When the bezel is to be mounted on the expander box. (W3 permits the HALT switch to light the RUN indicator.) When the bezel is part of the main box; that is, the CPU is mounted in this bezel's backplane. W4 When the bezel is part of the main box. (W4 enables the S RUN L signal to light the RUN indicator.) When the bezel is mounted on an expander box. 207 BA11-N SIDE 2 0 W1 0---0 0 0 W20---00 0 0---<>----0 W3 W4 0 0 0 0 0 0 0 0 0 ~" -- SWITCH CONTACTS (S3, S2, Sl) IT} 0 0 0 0 LED CONTACTS (RUN, PWR OK) BEZEL PRINTED CIRCUIT BOARD 12-12985 NOTES: 1. VIEW IS FROM THE REAR OF THE BEZEL WHEN THE BOARD IS MOUNTED ON THE BEZEL. 2. JUMPERS ARE MOUNTED ON SIDE 1. BEZEL ASSEMBLY JUMPERS JUMPER POSITION JUMPER IN JUMPER OUT W1,W2 WHEN THE BEZEL AUX ON/OFF SWITCH IS USED TO CONTROL THE POWER SUPPLY GENERATED LTC SIGNAL (WHEN THE SWITCH IS IN THE AUX ON POSITION, LTC·INITIATED INTERRUPTS ARE POSSIBLE). WHEN THE BEZEL AUX ON/OFF SWITCH IS USED TO TURN THE SYSTEM POWER CONTROLLER ON AND OFF. W3 WHEN THE BEZEL IS TO BE MOUNTED ON THE EXPANDER BOX (W3PERMITSTHE HALT SWITCH TO LIGHT THE RUN INDICATOR). WHEN THE BEZEL IS PART OF THE MAl N BOX, I.E., THE CPU IS MOUNTED IN THIS BEZEL'S BACKPLANE. W4 WHEN THE BEZE L IS PART OF THE MAIN BOX (W4 ENABLES THE S RUN L SIGNAL TO LIGHT THE RUN INDICATOR). WHEN THE BEZEL IS MOUNTED ON AN EXPANDER BOX. Bezel Printed Circuit Board 208 REAR OF BACKPLANE rT---I~~~~-:o:;----------Jf1 • o 1 +12 VDC 18) I 2 +12VDC SLOT D SLOT C SLOT B SLOT A BBl - W - l - - B POK H BR1-BEVE:rF~ ~~T~. : 3 GND +12 VDC I 4 GND +5 VDC • IROW 1) I I BACKPLANE P2-1 P2-2 2 P2-3 P2-4 BLANK PIN H9273 LOGIC ASSEMBL Y j.------'---b<i" 5 +5 VDC Pl 11 GND • GND • P2-5 P2-6 P2-7 ~~. - - - +5 VDC P2-8 6 +5 VDC IB) I-----+-+O~ I 7 GND +5 VDC I I I c=::=:::::J c=::=:::::J c:::===::::J c::==:=J L __ __ 8 +5 VDC GND GND ~ ~ L....----------' APl - - - B HALT L • 19 BAl - - - B DCOK H • 10 P2-9 P2-10 RO:"+-tr-+ _______ :J ~~ Jl0 J9 CABLE SIGNAL H786 CONTROL BOARD DC POWER HARNESS 7014091 H786 POWER J: " u "> ~ ~ '" I\) o (0 J r. J7-2 - 6 +12 VDC !'-=-":""':"-f-(i" 5 GND +12V IHGFEDCBI' 7011411 I MONITOR BOARD u u "" ~ "> ~ u a" >~ s! s! f- LKJIHGFEDCBA J2'-_ _ _ _ _ _ _---J -f-T--!l+ ±frfrfra-~rBBB~~~~~~ ~ h~~~~ ~ ~ ~ ) JS. 4 GND +5V ~,,-+-f-(i~ I 3 ~~-f-(i" GND +5V J: ...J 5~ 2 +5 VDC g~ !'-'-'--'-t--!><i~ I 1 +5 VDC ( '" '" "">~ a " " a L _____________________ _ SA 11-N Unit Interconnection (Sheet 1 of 2) ...J z ::;) 0: " u 0 ~ ~ ) N( AC POWER HARNESS 7014093 A*! A~I A) 0 SA 11-N BRN YELlGRN BLU LINE CORD, 115 VAC, 1700083-02 ~ LlNECORD,230VAC, 1700090-00 115/~OUT r-- -- -- -- -- -- ')- --, IJ3~ I J23~1 I I ...J Cl UJ AC INPUT BOX (H403-A) <! z Z l=<!J:::; I ~~ ~UJ ~ ~~ ~2 ~~~~~~~~~~ ~ ~ .:..: :..: . . . . . . :..:~ 1 I UJ ~~ Z I I ; ~~ ; ~ ~~ ~ ~~~ ~ 12 11 10 2 1 1 Pl IGA~.;-1I 115VAC ~ L_:..J AC POWER HARNESS 7014093 P3 Pl-l Pl-2 Pl-3 Pl-4 1 • ~I • LTC • S RUN L Pl-6 Pl-7 Pl-8 BLANK PIN GND GND ~ 1 •• +5 VDC • SPARE • B HALT L 10 • B DCOK H 1 :I Pl-9 Pl-l0 P2 ~J_l _ ( 1 2 0 o ______ SA 11-N Unit Interconnection (Sheet 2 of 2) 210 I I I I I B POK H :I • Pl-5 CABLE SIGNAL 7011411 , IFRONTPANEi:AsSv- 0 )J21 _.J BA 11-N Adjustments DC Voltage Measurement - The +5 Vdc and + 12 Vdc regulated voltages can be measured at J7 of the backplane or, preferably, at the tip jacks on the M8012 module. The pins of J7 are numbered, and the wires connected to them are color coded. + 12 Vdc and +5 Vdc are assigned the following pins and colors. + 12 Vdc - pin 2, purple wire + 12 Vdc ground -; pin 3, black wire +5 Vdc - pin 5, red wire +5 Vdc ground - pin 4, black wire The tip jacks on the M80 12 module are color coded and labeled as follows. + 12 Vdc - J3, purple +5 Vdc ground - J2, red - J 1, black Use a calibrated digital voltmeter to measure the voltages under normal load conditions. NOTE Do not measure the dc voltages without a load on the power supply; incorrect readings will result. The +5 Vdc output should be +5 V ± 250 mV, while the + 12 Vdc output should be + 12 V ± 600 mV. If either voltage is out of tolerance, adjust the appropriate potentiometer on the control board. R 1 varies the + 12 Vdc output and R22 varies the 5 Vdc output. The potentiometers are identified in the figure that follows. The correct output should be achieved when a potentiometer is near its mid-range position. If a potentiometer must be turned to near an extreme position to achieve tolerance limits, there is perhaps a problem somewhere in the regulator. If the output cannot be brought within limits, replace the entire control board. + 211 BA 11-N R22 +5 VDC ADJUSTMENT R1 +12 VDC ADJUSTMENT Power Supply Adjustments 212 BA 11-N Controls and Indicators Operation - The SA 11-N can have a blank front panel or one equipped with three switches and three indicators. In addition to the front panel switches and indicators, there is an ON/OFF switch and a primary voltage selection switch, both on the ac input box. The ON/OFF switch remains in the ON position when a power controller is used to apply primary .power to the SA 11-N; if a power controller is not used, the switch can be used to turn power on and off. BA 11-N Front Panel Switches and Indicators Switch Indicator AUX ON/OFF Function Can be used for any desired function (switch is rated at 48 V, 1 A dc). Two functions are explained below. If the SA 11-N is wired to control system power, the AUX switch turns the power on and off; if the SA 11-N is not wired to control system power, the switch can control the LTC signal, disabling the signal when the switch is in the OFF position. HALT In the down position, the HALT switch forces the CPU to suspend normal program execution, enables console ODT microcode operation, and permits single-instruction execution. To resume program execution, return the HALT switch to the up position and enter a P command from the console terminal (providing that the contents of register R7 were not changed). Refer to the Microcomputer Processor Handbook, ES-18451-20, for a description of console ODT command usage. In an expander box, the HALT switch can be used to light the RUN indicator. When the momentary RESTART switch is activated, the CPU automatically carries out a power-up sequence; thus, the CPU can be rebooted at any time from the front panel. RESTART PWR OK The PWR OK indicator lights when the power supply dc voltages are present. RUN The RUN indicator lights when the CPU is executing programs. 213 BA11-N AC Voltage Selection - The BA 11-N can be used with line voltage of either 115 Vac or 230 Vac. Only the ac line cord is different for the two voltages. However, a voltage selecting switch must be set to a position that corresponds to the line voltage being used. This switch is located on the rear of the ac input box, above the circuit breaker. The switch lever protrudes through a plate that is attached to the box. If the line voltage being used is 115 Vac, the designation" 115 Vac" should be printed on the plate above the switch lever. If the printing on the plate is 230 Vac, remove the plate. Flip the plate over and notice that 115 Vac is printed on the opposite side; also, notice that the switch lever itself is imprinted with 230 Vac. Move the switch lever down; 115 Vac should appear on the top of the lever. Replace the plate over the switch lever so that the printing on the outside of the plate reads" 115" Vac. (When the plate is on, the printing on the switch lever cannot be seen.) The plate is fabricated so that the screw holes in the plate and the input box line up only when the switch position corresponds to the printing on the outside of the plate. VOLTAGE SELECT SWITCH @ ~~8:'" TYPE 11 BA 11-N Voltage Select Switch 214 BA 11-N Backplanes J8 J7 <01 +12 VDC(8) e 2 +12 VDC (9 GND +12VDC <0 4 GND +5VDC SIGNAL CONNECTlONS •• • ••• ••• J9 e 5 +5VDC GND (9 6 +5VDC(8) <0 7 GND +5VDC e 8 +5VDC -12V H9273-A Power Connections A81 BR1-B BPOK H EVENT L AFl (ROWl) LTC SRUN L GND GND BA2,DA2 +5VDC APl BHALT L BAl BDCOK H H9273-A Signal Connections 215 BA11-N CONNECTOR 1 CONNECTOR 2 r---------~~--------~, (~-----------'----------~ SLOT A SLOT B SLOT C SLOT D ~ ~ ~ W1 ROW 1 (PROCESSO:R (OR M9401) ROW2 OPTIPN 1 ROW3 OPTI:ON 2 ROW4 OPTI:ON 3 ROW5 OPTI:ON 4 ROW6 OPTIPN 5 ROW 7 OPTI:ON 6 ROW8 OPTIPN 7 ROW9 OPTIPN 8 W2 W3 CD INTERCONNECT IN THESE SLOTS VIEW IS FROM MODULE SIDE OF CONNECTORS. BACKPLANE JUMPERS JUMPER POSITION JUMPER(SIIN JUMPER(SIOUT W1 WHEN THE H786 POWER SUPPLY GENE RATED LTC SIGNAL IS USED TO ASSE RT THE LSll1 BUS BEVNT L SIGNAL. WHEN IT IS NOT DESIRED TO HAVE LINE TIME CLOCK (LTCI SOURCING BEVNT L, SUCH AS WHEN AN EXTERNAL SOURCE IS USED INSTEAD. W2, W3 WHEN A CPU MODULE IS INSERTED IN ROW 1 OF THE BACKPLANE. WHEN ANY OTHER MODULE IS INSTALLED IN ROW 1, I.E., WHEN THE BACKPLANE IS PART OF AN EXPANDE R BOX. H9273-A Backplane Connectors 216 BA 11-N CO Bus Signals - The CO bus signals are supplied by slots C and O. The + 5 V supply voltage is bused to all rows on pin A2 of slots C and 0 (that is, pins CA2 and OA2). Likewise, ground connections on pins CC2, CT 1, OC2, and OT 1 are bused to all rows. All other pins connect only to an adjacent row. For example, pin CF2 of any row connects only to pin CF 1 of the adjacent higher-numbered row. Pins on side 2 of the slot (B2, C2, etc.) connect to the adjacent higher-numbered row (except OT2, which connects to CT2 of the adjacent lower-numbered row), while pins on side 1 of the slot (B 1, C 1, etc.) connect to the adjacent lower-numbered row (except pin A 1, which connects to C 1 of the adjacent higher-numbered row). Thus, each row, except 1 and 9, has 33 signal connections (other than + 5 V and ground) to both the adjacent higher-numbered row and the adjacent lower-numbered row. To facilitate references to these two groups of 33 signals, group 1 is defined as the group of signals connecting a row (row X) to its adjacent lower-numbered row (row X-1). Group 2 is defined as the group of signals connecting a row to its adjacent higher-numbered row (row X+ 1). Generally, group 1 signals are found on side 1 pins, while group 2 signals are found on side 2 pins. BA 11-M/BA 11-N Expansion Configuration • The LTC is sourcing the BEVNT L in the BA 11-MA box. (BOV 11 is not being used.) • Power is controlled by the 861 C power controller ON/OFF switch. NOTES 1. If a BOV 11, with E21 switch 5 "on," is used as the last module in the BA 11-WE, install W1 in the BA 11-NE backplane. Turn off LTC switch (must remain off) in the BA 11MA. 2. BCV1B-XX' configuration: M9400 KE in first A-B slot after options in BA 11-MA backplane. M9400 KO in first A-B slot in BA 11-NE backplane. * XX denotes cable length. 217 CD » ... ... ROW1 PROCESSOR ROW2 OPTION ROW3 OPTION (AC IN) "\ ./ r \. '\ ./ ROW4 Z OPTION OPTION BAll-MA BOX OPTION ) OPTION I-- I 861-C POWER CONTROLLER MAX. CABLE LENGTH 3_05 M (10 FT) SWITCHED OUTPUTS (2)BC05 - L !---BCV1B - XX (NOTE 2) rROW 1 J3AC OUT J2 (AC IN) NOTE LEAVE DC SWITCH POSITIONED ON_ ROW 2 OPTION ROW3 OPTION ROW4 OPTION ROW 5 OPTION ROW 6 OPTION ROW 7 OPTION ROW 8 OPTION ROW9 BAll - NE BOX BA11-NE BACKPLANE JUMPERS TERMINATOR (NOTE1) W1 - OUT W2 -OUT W3- OUT VIEW IS FROM MODULE SIDE OF CONNECTORS_ BA 11-MA to an NE Box Expansion MR.4973 BA 11-N . . CONNECTOR 2 CONNECTOR 1 SLOT A. J3ACOUTROW 1 AUX ON/OFF SWITCH IBEZE L PANEL) SLOT B SLOT C SLOT D ~ ~ ~ PROCESSOR ROW2 OPTION 1 ROW3 OPTION 2 ROW4 OPTION 3 ROW5 OPTION 4 BAllNC J2 AC IN ROW 6 OPTION 5 ROW7 OPTION 6 ROWS OPTION 7 ROW9 I '-- MAX. CABLE LENGTH 3.05 M 11 OFT) S61C (2) BC05· L _BCV1S·XX ~ ROW 1 AC IN ROW2 OPTION ( ROW3 OPTION \. "\ .J OPTION OPTION OPTION "TERMINATOR ROW4 "AN ECO MUST BE INSTALLED IN THE SLAVE BOARD I FA BDV11 IS USED IN A SA 11·M BOX. SA 11-NC to an ME Sox Expansion SA 11-NC backplane jumpers: W1 - IN W2 -IN W3 -IN (If M7264 or M7264-YA CPU is present. If not, remove jumper.) SA 11-NC bezel jumpers: W1 - OUT W2 - OUT When bezel AUX ON/OFF switch is used to turn system power controller on or off; otherwise IN. W3 - OUT W4 - IN NOTES 1. If a BDV11, with E21 switch 5 "on," is used as the last module in the BA 11-ME, install ECO (see Appendix B) in backplane of BA 11-ME. Remove W1 from the backplane of BA11-NC. 2. BCV1B-XX configuration: see BA 11 MA/NE configuration figure. 219 BA11-N . . CONNECTOR I SLOT A 861C POWER CONTROLLER SWITCHED OUTPUT I I SLOT B SLOTC SLOT D ~ ~ ~ PROCESSOR ROWI i CONNECTOR 2 ROW2 OPTION I ROW 3 OPTION 2 ROW4 OPTION 3 ROW5 OPTION 4 ROW6 OPTION 5 ROW 7 OPTION 6 ROW8 OPTION 7 J2 AC IN BAlI BOX NC ROW9 "MAX. CABLE LENGTH 3.05 M (I OFT) (2) BC05· L ROWI 6--~ r- WI J3 AC OUT"ii"O'WT OPTION J2 AC IN ROW 3 OPTION ROW4 OPTION ROW5 OPTION ROW6 OPTION ROW7 OPTION ROW8 !---BCVIB. XX BAll· NE BOX OPTION TERMINATOR ROW9 BA 11-N to Another N Box Expansion NOTES 1. If a BDV 11, with E21 switch 5 "on," is used as the last module in the BA 11-NK, install W1 in the BA 11-NK backplane. Remove W1 from the BA 11-NC backplane. 2. BCV 1B-XX· configuration: M9400 KE in first A-B slot after options in BA 11-NC. 9400 KD in first A-B slot of BA 11-NK• .. XX denotes cable length. 220 BA 11-N BA 11-NC backplane jumpers: W1 I W21 W3 I If using CPU M7264 or M7264-YA; otherwise R. BA 11-NC bezel jumpers: W1 I W21 W3R W41 BA 11-NE backplane jumpers: W1 R W2R W3R CAUTION Do not attempt to source ac power for the BA 11-N mounting box from the BA 11-N box ac outlet, because the current rating of the BA 11-N box will be exceeded and severe damage may occur. Also, do not attempt to provide ac power to three BA 11N boxes from one 861 C power controller. 221 BA 11-N (AC IN) ROW 1 PROCESSOR ROW2 OPTION ROW3 OPTION '\ .J r OPTION -- \. ROW4 OPTION 1 1 .. OPTION -----1 '-- MAX. CABLE LENGTH 1.83 M ( 6 FTI (2) Wl ;- o~--o ROW 1 ~u~CRl5W2 B61C PWR CTRL. SWITCHED OUTPUT ,~ I J2 (AC IN) I+----- BCV 1B XX BC05·L OPTION ROW3 OPTION ROW4 OPTION ROW5 OPTION ROW6 OPTION ROW7 OPTION ROW8 OPTION BAll BOX ROW9 '-- MAX. CABLE LENGTH 3.05 M (1 OFT) (2) I+----- BCV 1A XX BC05L ;- ROW 1 AC IN -~ ROW2 OPTION ROW3 OPTION J ~ \ \ TERMINATOR ROW4 OPTION OPTION OPTION (NOTE 1) ·AN ECO MUST BE INSTALLED IN THE SLAVE BOARC IF A BDVl 1 IS USED IN A BAl 1-M BOX BAll·NE BACKPLANE JUMPERS Wl - OUT (NOTE 1) W2 - OUT W3 - OUT BA 11-MA to an ME Box Expansion NOTES 1. If a BOV11, with E21 switch 5 "on," is used as the last module in the BA 11-ME, install ECO (see Appendix B) in the BA 11-ME backplane. Remove W1 from this BA 11-NE backplane. Turn off LTC switch (must remain off) on BA 11MA. 2. BCV1B-XX' configuration": BCV1A-XX; M9400 YO in first AB slot after options in BA 11-NE; M9401 in first A-B slot in BA 11-ME backplane. • XX denotes cable length. • • See BA 11-MA to an NE Box Expansion figure. (See Appendix B for ECO information.) 222 NE DLV11-KA DLV11-KA EIA TO 20 MA CONVERTER Amps +S o Bus Loads -12 0 AC N/A DC N/A Cables BC21 A-03 EIA BCOSF-XX 20 rnA + 12 V@ 0.27S max. (supplied by EIA SLU interface module). Standard Addresses and Vectors, Diagnostic Programs None Related Documentation DLV11-KA ElA to 20 mA Installation Guide (EK-DLVKA-IN) DL V 11-KA Maintenance Print Set (MP00694) Microcomputer Interfaces Handbook (EB-2017S-20) CONFIGURATION General The DL V 11-K requires the configuration of 11 jumper wire connections and 1 capacitor connection. The configurations and functions of these jumpers are shown in the following table. DLV11-KB Jumper Configurations Function Jumper In Jumper Out Passive 20 mA Receiver Active 20 rnA Receiver" Passive 20 rnA Transmitter Active 20 rnA Transmitter" 110 Baud Enabled" 110 Baud Disabled Noise Suppression W7,W9 W6, W8, W10 W2,W4 W1, W3, WS W11 W6, W8, W10 W7,W9 W1, W3, WS W2,W4 See following Note. "Factory configuration 223 W11 See following Note. DLV11-KA NOTE For use with an ASR-33 Teletype™, insert a 0.047 JLFaxial ceramic capacitor (DEC PN 10-12784-00) in the location designated C. This capacitor is inserted for the factory configuration. For any other terminal there is nothing inserted in this location. For proper operation of Teletype ASR-33 with DEC-supplied paper tape software, the SLU should be configured for eight data bits, two stop bits, and no parity. The Teletype models can be L T33-DC, L T33-DD, L T33-DE, or an ASR-33 Teletype with the LT33-MB modification kit installed. J1 0--011 O--OC 60--0 0--01 70--0 O--OB , L - - - - - - - l 90--0 r-----,,----' 4 0--03 5 g:::g 20--0 0--0 10 NOTE: THE NUMBER 2 INDICATES THAT IT IS THE W2 JUMPER WI RE. DL V 11-KB Jumper Locations Installation Requirements The DL V 11-KA option can be installed in a system that requires conversion from EIA RS-232 standard to a 20 rnA current loop. The DL V 11-KA option consists of a DL V 11-KB converter box and a BC21 A-03 interface cable as shown in the preceding illustration. The BC21A-03 is a 0.9 m (3 ft) cable that interconnects the DL V 11-KB to an EIA SLU interface module. The smaller connector (2 X 5 pin) connects to the SLU module and the larger connector (2 X 7 pin) connects to the DL V 11-KB box. Keying is provided on both connectors, and cable retention is provided by "locking pins" on the SLU connector. To disengage, pull back on the connector shell and the connector will slide free. However, if the cable is pulled, the locking pins will hold the connector firmly in place. A BC05F-XX cable can be used to connect the DL V 11-KB converter box to DEC 20 rnA terminals including the DEC-modified ASR-33 Teletype. 224 DLV11-KA Cabling Cables other than the DEC BC05F-XX can be used when installing the DLV 11-KA option. However, any other cable must conform to the following parameters to meet the baud rate versus cable length specification. 1. Resistance - NMT 30 Q/305 m (1000 ft) (NL T 22 AWG) 2. Capacitance to ground - NMT 50 pF /ft 3. Capacitance wire-to-wire - NMT 35 pF /ft The BC05F-XX cable meets the above requirements. If the user desires to use shielded cable, the shield should be grounded to the chassis at the entry point and not to the DL V 11-KB converter box. The user can fabricate custom cables for the 20 mA interface by using DEC connector, PN 1209340-01 (AMP PN 1-480460-0), and pins PN 1209378-03 (AMP PN 350079-4). Baud Rate The DL V 11-KA option will operate up to a maximum of 9600 baud, provided that the interface module can accommodate these rates. However, the maximum operational baud rate is also limited by the length of cable. Maximum recommended cable lengths for the specific baud rates are given in the following table. These recommendations are conservative and will yield satisfactory operation for almost all applications. These guidelines may be exceeded, but this should only be done after reviewing the DLV 11-KA specifications, the severity of the operating environment, and the error rate that can be tolerated. Baud Rate vs Cable Length Baud Rate Max. Cable Length 9600 4800 2400 1200 600 300 110 30 m (100 ft) 76 m (250 ft) 152 m (500 ft) 305 m (1000 ft) 610 m (2000 ft) 1220 m (4000 ft) 1220 m (4000 ft) 225 DLV11-KA Terminal Recommendations DIGITAL Terminals orSLUs Active DLV11-KA Max. Cable Length (22 GA) DLV11 DLV11-F DLV11-KA M598 LA36 VT52 LA180S LA120 VT100 LA120 Teletype ASR-33 1220 m (4000 tt) 1220 m (4000 tt) 1220 m (4000 tt) 1220 m (4000 tt) 457 m (1500 tt) 1220 m (4000 ft) 1220 m (4000 tt) 1220 m (4000 tt) 1220 m (4000 ft) 1220 m (4000 tt) 305 m (1000 ft) Passive DLV11-KA Max. Max. Max. Cable Baud Length Baud Rate (22 GA) Rate ·· ··.. ·· ·. ·. 9600 9600 300 9600 NA 9600 9600 110 NA 9600 9600 NA 9600 9600 300 9600 1220 m (4000 tt) 457 m (1500 tt) ·· ·. ·. NA 671 m (2200 tt) · Operation at 9600 baud only recommended tor benign environments. Operation with more than 8 m (25 ft) ot cable is not recommended. PASSIVE RECEIVER ACTIVE TRANSMITTER CURRENT SOURCE XMIT + 1 T - IN TERFA CE CABLE REC - " I A'. XMIT I I CURRENT DETECTOR I RCVR I RECEIVED DATA I " REC - _ _ _ _ _ _ _ _ ...J 20MA LOOP I + TRANSMITTEO DATA ACTIVE RECEIVER RECEIVED DATA ----------. PASSIVE TRANSMITTER I 1 T CURRENT SOURCE I CURRENT I I DETECTOR I XMIT REC + - " 1 ... XMIT REC - + Standard Current Loop Interface 226 20MA LOOP XMTR TRA NSMITTED OAT A DLV11-KA DLV11-KA OPTION BC21A-03 CABLE BC05F-XX CABLE ,----A----... P1 +12 VDC P2 10) 1 ( < 2 2 ( < 3 3 ( SIG GND 9 ) EIA OUT 8 ) SIG GND EIA SLU INTERFACE MODULE SUCH AS THE DLV11-J (4 7 ) SIG GND 5 ) I I 6~I 4 ) KEY < 5 ~6 4 ( DLVll-KB EIA TO 20mA CONVERTER BOX I READER PLS f 2 X 5 PIN AMP CONN READER CL OUT + 5 ( READER + CL IN + 7 ( < 8 B~(---- (NC) f SIG GND < 9 MATE 'N' LOK CONN 110BAUD 1 ) CL IN- < 7 EIA IN 2 ) CL OUT- 6 ( I 3 ) (NC) J2 J1 < 1 <10 f 2 X 5 PIN BERG CONN TO 20mA DEVICE J2 MATE 'N' LOK CONNECTOR KEY (NO PIN) J1 BERG CONNECTOR DLV 11-KA Typical Installation 227 DLV11-KA DLVll-J TO 20 MA TERMINAL . ~ ,\~~ LT33-DC/DD/DE OR ASR33 WITH LT33-MD MODIFICATION KIT_ DLVll-KA PRISOl A A NOTE 1. PRISOI IS A SERIAL LINE PAPERTAPE LOADER. Typical Installation 228 ~- '. G653/H223 G653/H223 MMV11-A CORE RAM MEMORY Amps +5 Stby. Act. 3.0 7.0 + 12 0.2 0.6 Bus Loads Cables AC 1.91 None DC Standard Address Not applicable Vectors None Diagnostic Programs Refer to Appendix A. Related Documentation Microcomputer Processor Handbook (EB-18451-20) 11 V03 Field Maintenance Print Set (MP00094) NOTE Because of addressing limitations, this module is not compatible with PDP-11 /23 systems with more than 64K bytes of memory. 229 G653/H223 Backplane Jumpers When installing the MMV 11-A in any slot but the last slot in a backplane, two jumpers must be inserted on the backplane to maintain the interrupt and DMA daisy-chain grants. If the MMV 11-A is placed in an even-numbered slot, the jumpers must connect as follows. in the option slot preceding MMV 11-A to the option slot following MMV 11-A CN2 CS2 CM2 CR2 If the MMV 11-A is placed in an odd-numbered slot, the jumpers must connect as follows. in the option slot preceding MMV 11-A in the option slot following MMV 11-A AN2 AS2 AM2 AR2 NOTE The MMV11-A cannot be used in the BA 11-N mounting box, in the H9273 backplane, or in any other backplane that does not have the LSI-11 bus pinning in the "C" and "0" slots. 230 G653/H223 ~ SWl SW2 SW3 SW4 (NOT USED) G653/H223 ~m-15 14 ADDRESS WORD 13 L 1 J I L I 1 I I J 1 I L -----y I 4096 LOCATION ADDRESS SW3 SW2 SWI BANK ON ON ON ON OFF OFF OFF OFF ON ON OFF OFF ON ON OFF OFF ON OFF ON OFF ON OFF ON OFF 0 1 2 3 4 5 6 7 o - 17776 37776 57776 77 776 117776 137776 157776 177776 MMV 11-A Addressing 231 J 1 BYTE POINTER ADDRESSES 20000 40000 60000 100000 120000 140000 160000 - 1 NOTE Bank 7 is norma Ily reserved for peripherals. H780 H780 POWER SUPPLIES H780 Power Supplies Models, specifications, and basic adjustments are presented in this section. For more detailed technical information, refer to H780-C,-D,-H,-J, -K,-L Power Supply User's Manual, EK-H780C-OP-00 1, or to Microcomputer Handbook, EB0794853. H780 Specifications Input Voltage 100 Vac-127 Vac (H780-A, -C, -E, -H, -K, -M, -P) 200 Vac-254 Vac (H780-B, -D, -F, -J, -L, -N, -R) Operation from ac lines below 100 V may cause the power supply to overheat because of decreased air flow from the cooling fans. Temporary Line Dips Allowed 100% of voltage, 20 ms max. AC Inrush Current 70 A @ 127 V, 60 Hz (8.33 ms) 25 A @ 254 V, 50 Hz (10 ms) Fuses 5.0 A fast blow for 115 Vac options 2.5 A fast blow for 230 Vac options Input Power (Fans Included) 340 W @ full load max 290 W @ full load typical EMI (Emission and Susceptibility) Per DEC STD. 102.7 and VDE N-12 limits Output Power (Combinations not to exceed 110 W) +5V1.5A-18A + 12 V 0.25 A-3.5 A 232 H780 +5 V Output Total regulation Line regulation Load regulation Ripple Dynamic load regulation Noise Interaction due to + 12 V + 12 V Output Total regulation Line regulation Load regulation Ripple Dynamic load regulation Noise Interaction due to + 5 V Overvoltage Protection +5V + 12 V Adjustments +5 V output + 12 V output 5 V ±3% ±0.5% ± 1.0% 150 mV p-p (1% for f <3 kHz) ± 1.2% di/dt = 1.5 A/s .61=5A 1% peak at f > 100 kHz (noise is superimposed on ripple) ±0.05% 12 V ±3% ±0.25% ±0.5% 350 mV p-p (1% for f < 3 kHz) ±0.8% di/dt = 0.5 A/ s f < 500 Hz .61=3A 1% peak f > 100 kHz (noise is superimposed on ripple) ±0.2% 6.3 V nominal min. = 5.65 V max. = 6.8 V 15 V nominal min. = 13.6 V max. = 16.5 V 4.05 V-6.8 V guarantee range 4.55 V-5.65 V 10.6 V-16.5 V guarantee range 11.7 V - 13.6 V Backplane Signals BPOK H BDeOK H BEVNT L BHALT L SRUN L 233 H780 Size 13.97 em w X 8.43 em h X 37.15 em 1 (5-1/2 in w X 3-1/3 in h X 14-5/8 in I) Weight 5.90 kg (13 Ibs) +5 V F REOUENCY ADJUST (R96) CW - DECREASE CCW - INCREASE +-12 V OUTPUT ADJUST (R87) ccw - INCREASE CW - DECREASE '---- --- . +5 V OUTPUT ADJUST (R88) CCW - INCREASE CW - DECREASE - ~ .-~ .... H780 Voltage Adjustments 234 H780 H780 Controls and Indicators Control! Indicator Type Function DC ON LED Indicator Illuminates when the DC ON/OFF toggle switch is set to ON and proper dc output voltages are being produced by the H780. If either the + 5 V or + 12 V output from the H780 is faulty, the DC ON indicator will not illuminate. This is the only indicator on the H780-K and -L slave supplies. RUN LED Indicator Illuminates when the LSI-11 or PDP-11 /03 processor is in the run state (see ENABLE/HAL T). SPARE LED Indicator Not used by the H780 or processor. The H780 contains circuitry for driving this indicator for user applications. DC ON/OFF Two-Position Toggle Switch When set to ON, enables the dc outputs of the H780. The DC ON indicator will illuminate if the H780 dc output voltages are of proper values. If a slave supply is connected to a master, the slave DC ON indicator will light if the slave dc output voltages are of proper value. When set to OFF, the dc outputs from the H780 are disabled and the DC ON indicator is extinguished. If a slave supply is connected to a master, the slave DC ON indicator will also be extinguished. ENABLE/HALT Two-Position Toggle Switch When set to ENABLE, the BHAL T L line from the H780 to the LSI-11 bus is not asserted and the processor is in the run mode (RUN indicator illuminated). When set to HALT, the BHAL T L line is asserted, allowing the processor to execute console ODT microcode (RUN indicator extinguished). 235 H780 H780 Controls and Indicators (Cont) Control/ Indicator LTC ON/OFF Type Function Two-Position Toggle Switch When set to ON, enables the generation of the line time clock (LTC) by the H780. When set to OFF, disables the H780 line time clock. AC ON/OFF (Rear Panel) Two-Position Toggle Switch When set to ON, applies ac power to the H780. When set to OFF, removes ac power from the H780. FUSE (Rear Panel) 5 A or 2.5 A Fast Blow Protects H780 from excessive current. H780-C, -H, and -K use a 5 A fuse. H7800, -J, and -L use a 2.5 A. 236 M7264-XX M7264-XX LSI-11 PROCESSOR MODULES Processor option designations and processor module numbers do not have a one-for-one correspondence. This section describes processors both in terms of option designations (KD 11-X) and module numbers (M7264-XX). When replacing chip sets, check both the number on the handle and etch revision on the board. The jumpers are defined in this section; however, the "Systems Configurations" section presents the general rules for configuring refresh reply. For details of differences between various revisions of the processor modules, refer to Appendix B of the Microcomputer Processor Handbook, EB-18451-20. For all commercial products systems, refer to the DEC Datasystem 320 Family Service Manual, EK-DDS03-SV-001, available in hard copy or microfiche. Processor Model Designations KD 11-F Processor with 4K RAM: M7264 Mostek 4096 M7264-AB Intel® 2104 M7264-CB Fujitsu 8224 M7264-DB Intel 2104-A M2264-EB Mostek 4027 M7264-FB DEC 4027 M7264-HB Motorola 4027 M7264-JB Fujitsu 8227 KD 11-H (M7264- Y A) Processor without 4K RAM EIS/FIS option can be added: Etch Revs C and D use KEV 11 Etch Rev D uses KEV 11-B (EIS only) Etch Revs E and Fuse KEV 11-A KD 11-L Processor with on-board 4K RAM and EIS/FIS: Etch Rev C or D KD11-F plus KEV11 or Etch Rev E or F KD11-F plus KEV11-A 237 M7264-XX KD 11-N Processor without on-board 4K RAM and with EIS/FIS: Etch Rev C or 0 KD11-H plus KEV11 or Etch Rev E or F KD11-H plus KEV11-A KD11-P Processor with on-board 4K RAM and with DIS: Etch Rev E or F M7264-BB plus KEV 11-CA KD11-Q Processor without on-board 4K RAM and with DIS: Etch Rev E or F M7264-YB plus KEV11-CA ... M7264 Specifications Size: Quad-height module 26.6 cm (10.5 inches) X 22.8 cm (8.9 inches) Power: +5V ±5%, 1.8 A + 12V ± 5%,0.8A Bus Loads: AC - 2.4 unit loads DC - 1 unit load Environment: DEC STD 102 Class C Related Documentation Microcomputer Processor Handbook (EB-18451-20) KD 11-F Field Maintenance Print Set (MP-00049-00) KD 11-H Field Maintenance Print Set (MP-00050-00) KD 11-P Field Maintenance Print Set (MP-00264-00) KD11-Q Field Maintenance Print Set (MP-00357-00) KD 11-WA Field Maintenance Print Set (MP-00569-00) LSI-11 Maintenance Card (EK-LSI11-MC) 238 M7264-XX E41 E47 :r: --' f- 0 ~ 0:: f- « « Cl z f- 0 U M7264 ETCH REV. C, D (W7 . W11 NOT USED) W8 mm[H 'W1O I II E58 --' E53 :r: 0 f- f- « f« Cl 0:: z 0 U ~ I r I W1 • W2 • W11 • W3 • W4 Y • JUMPERS PRESENT ONLY WHEN ON·BOARD MEMORY IS PRESENT NOTE M7264 ETCH REV E AND AFTER 239 M7264-XX E53 IW1* I I I GG l- ~ W2* <{ l- <{ Cl Wll' I W3* wlO*I I W4 • JUMPERS PRESENT ONLY WHEN ON-BOARD MEMORY IS PRESENT. M7264-BB DIBOL Processor Jumper Function W1 Insert to select resident memory bank 1. W2 Insert to select resident memory bank O. W3 Remove to enable event line (LTC) interrupt. W4 Remove to enable processor controlled memory refresh. W5,} Power-Up Modes W6 Mode o 1 2 3 Jumpers W6 W5 R R I I R I R I Mode Selected PC at 24 and PS at 26, or halt mode ODT microcode. PC at 173000 for user bootstrap Special processor microcode (not implemented). 240 M7264-XX Jumper Function W7 Factory-selected biasing voltage. Installed for VDATA = VROM. W8 Factory-selected biasing voltage. Installed for VCTL = VROM. W9 Remove to enable reply from resident memory. W 10 Remove to enable reply from resident memory during refresh. W11 Enable on-board memory select. Processor Module Jumper States (LSI-11 Without On-Board Memory) (LSI-11 With 4K On-Board Memory) Jumper KD11-F, -L KD 11-P KD 11-H, -J, -M, -R, -S, -U KD11-Q W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 W11 R I R R R R R I R I R I R R R I R R R R R I R I R R I R R I I R R I R R * May vary with ECO level. Do not alter. 241 M7264-XX Diagnostic Programs The following diagnostic programs are for use with LSI-11 processors except for the limitations noted. VKAA?? LSI-11 basic instruction test VKAB?? LSI-11 Extended Instruction Set (EIS) test. This program can only be run on LSI-11 CPUs with the KEV 1"1 (EIS/FIS) or KEV 11-CA (OIBOL instruction set) options installed. VKAC?? LSI-11 Floating Point Instruction (FIS) test. This runs only on LSI-11 CPUs that have the KEV 11 (EIS/FIS) option (2300385). NOTE The KD 11-P (or Q) supports DIS (DIBOL Instruction Set) and EIS (Extended Instruction Set) but not FIS (Floating Instruction Set). Therefore, FIS test (-VKACAO) will not run on a D322 or D324. VKAO?? LSI-11 traps test. This diagnostic auto-sizes for the EIS, FIS, and OIBOL options. • Older versions (Rev B 1 and below) require the setting of a bit in the software switch register if EIS, FIS, or OIBOL is present. • Rev A diagnostics will not run on 0322 or 0324 systems because of the DIS instructions. NOTE See Appendix A for XXDP + multimedia aSSignments. VKAH?? Basic system exerciser. Tests serial line unit, memory, processor, EIS/FIS, clock, and both flQPpy disks under various conditions. Software switch register must be set for options. VKAI?? DIS move and string instruction tests. This diagnostic tests the OIBOL instruction set. The CPU must have KEV 11-CA (DIS) option installed. Ref 0322, 324. VKAJ?? DIS decimal instruction tests. This diagnostic tests the 01BOL instruction set. The CPU must have the KEV 11-CA (DIS) option installed. Ref 0322, 324. 242 M7264-XX ~ ________________________~607~H________ 1 TYPICAL CIRCUIT SCHEMATIC REVISION IDENTIFIER (EG. CS-M7264 REV. H) N W Cl iii M ":- TYPICAL ETCH REVISION ~-IOENTIFIER (EG. ETCH REV. 0) M7264 Revision Identifiers M7264-YA Etch Rev C V BB Comments Chip Vendor Number DEC Number DATA CONTROL MICROM-O MICROM-1 CP 1611 8-51 CP 1621 8-451 CP 1631 8-3006 CP 16318-3010 CP 1631 8-3007 2 1-11549-00 23-001 C2-0 1 23-086A5-0 1 23-088A5-0 1 23-087 A5-0 1 -5.1 -5.1 2004 pattern -5.1 Without ECO 2 -5.1 With ECO 2 -5.1 EIS/FIS (if present) KEV11 CP16318-3015 23-091 A5-0 1 -5.1 RAMs M7264 M7264-YA Mostek None 21-11749 -9 243 Without ECO 2A With ECO 2A M7264-XX M7264-AB, M7264-YA Etch Rev D Chip Vendor Number DEC Number Vaa Comments DATA MICROM-O MICROM-1 CP 1611 8-51 CP 1631 8-3010 CP 1631 8-3007 2111549-00 23-088A5-0 1 23-087 A5-0 1 -5.1 -5.1 -5.1 2004 pattern EIS/FIS (if present) KEV11 CP 1631 8-3015 23-091 A5-0 1 -5.1 KEV11-8 (EIS only) CP 1631 8-12 12-090A5-0 1 -3.9 RAMs M7264 M7264 M7264-A8 M7264-YA Mostek Mostek 4096 Intel 2104 None 21-11749 21-12726-00 21-12958-01 -9 -5.1 -5.1 Without ECO 4 With ECO 4 With ECO 4 Not present M7264-AB, M7264-YA Etch Rev E Comments Chip Vendor Number DEC Number Vaa DATA CP 1611 8-39 PO 1611 H 21-11549-01 21-15579-00 -3.9 -3.9 With ECO 21 CP 1621 8-173 CP 1621 8-439 23-002C4 23-001C3 -3.9 -3.9 With ECO 12 Without ECO 12 MICROM-O MICROM-1 CP 1631 8- 103 CP 1631 8-073 23-00185 23-00285 -3.9 -3.9 EIS/FIS (if present) KEV11-A CP 1631 8 23-00385 -3.9 RAMs M7264 M7264-A8 M7264-YA Mostek 4096 Intel 2104 None 21-12726-00 21- 12958-01 -5.1 -5.1 CONTROL 2004 pattern Not present 244 M7264-XX M7264-BB, M7264-YB Etch Rev E Chip Vendor Number DEC Number Vee Comments DATA CP 1611 8-51 CP 1611 8-39 PO 1611 H 21-11549 21-11549-01 21-15579-00 -5.1 -3.9 -3.9 Without ECO 5 With ECO 5 With ECO 21 CP 1621 8-451 23-001 C2-0 1 -5.1 With ECO 5 2007 pattern CP 1621 8-439 CP 1621 8-173 CP 1621 8 23-001C3 23-002C4 23-003C3 -3.9 -3.9 -3.9 Without ECO 12 With ECO 12 With ECO 21 * MICROM-0/1 CP 1631 8-3010 23-00BA5-0 1 23-00186 23-00286 23-00386 -5.1 -3.9 -3.9 -3.9 Without ECO 10 With ECO 10 With ECO 12 With ECO 16 23-00485 23-00585 -3.9 -3.9 3025 pattern 3026 pattern 21-12726-00 -5.1 CONTROL 2004 pattern DIS (KEV11-CA) DIS 2 DIS 3 RAMs M7264-88 M7264-Y8 Mostek 4096 None Not present *This part of ECO 21 applies to M7264-88 and -Y8 variations only. 245 M7264-XX M7264-CB, M7264-DB Etch Rev E Chip Vendor Number DEC Number V BB DATA CONTROL MICROM-O MICROM-1 CP 1611 8-39 PO 1611 H CP 1621 8-173 CP 16318-103 CP 1631 8-073 2 1- 11549-01 21-15579-00 23-001C4 23-00185 23-00285 -3.9 -3.9 -3.9 -3.9 -3.9 EIS/FIS (if present) KEV11-A CP 1631 8 23-00385 -3.9 RAMs M7264-C8 M7264-D8 Fujitsu 8224 Intel 2104A 21-13787-01 21-13795-01 -3.9 -3.9 Comments With ECO 21 2007 pattern M7264, M7264-AB, -CB, -DB, -EB, -FB, -HB, -JB Etch Rev F Chip Vendor Number DEC Number V BB DATA CONTROL MICROM-O MICROM-1 CP 1611 8-39 PO 1611 H CP 1621 8-173 CP 1631 8-103 CP 1631 8-073 2 1- 11549-01 21-15579-00 23-002C4 23-00185 23-00285 -3.9 -3.9 -3.9 -3.9 -3.9 EIS/FIS (if present) KEV11-A CP 1631 8-135 23-00385 -3.9 RAMs M7264 M7264-A8 M7264-C8 M7264-D8 M7264-E8 M7264-F8 M7264-H8 M7264-J8 Mostek 4096 Intel 2104 Fujitsu 8224 Intel 2104A Mostek 4027 DEC 4027 Motorola 4027 Fujitsu 8227 21-12726-00 21-12958-01 21-13787-01 21-13795-01 21-13735-01 2 1- 12914-01 21- 14114-01 2 1- 14475-01 246 -3.9 -3.9 Comments With ECO 21 2007 pattern 350 ns 350 ns 350 ns 350 ns 200 ns 200 ns 200 ns 200 ns M7264-XX M7264-BB, M7264-YB Etch Rev F Chip Vendor Number DEC Number Vaa Comments DATA CP 1611 B-39 PO 1611 H CP 1621 B-173 With ECO 21 CONTROL MICROM-O MICROM-1 CP 1631 B-101 -3.9 -3.9 -3.9 -3.9 -3.9 With ECO 21 Not present DIS KEV11-CA DIS 2 DIS 3 RAMs M7264-BB M7264-YB 21-11549-01 21-15579-00 23-002C4 23-003C3 23-003B6 Mostek 4096 None 23-004B5 23-005B5 -3.9 -3.9 21-12726-00 -5.1 350 ns Not present Circuit Schematic/ECO History Etch Rev CS Rev ECO No. C C C D 1 Change value of C8 in clock pulse generator circuit from 150 pF to 47 pF. C E 2 1. Logic changed to clock BRPL Y into reply flipflop with an earlier timing signal. Change (Basic model) 2. Logic changed to disable BBS7 L for the duration of BDMG L or BSACK L assertion. 3. SRUN L signal decoded and applied to backplane. 4. ECO 2A created M7264-Y A. D F 3 Logic changes for etch Rev C boards. D H 4 Circuit changes implemented to provide -5 V. Documentation updated by ECO 4A. 247 M7264-XX Circuit Schematic/ECO History (Cont) Etch Rev CS Rev ECO No. E J 5 New module layout. (OM A synchronization logic changed.) Add jumpers for resident memory reply and refresh reply. Add factory jumpers for Vaa selection. Logic change to allow external selection of resident memory. Add factory adjustment (R 15) for setting refresh clock to 1.6 ms. Terminate bus lines AA1, AB1, AC1, AD1, and BP1. Replace E53, E58, E63, E70 with -3.9 V chips. E K 6 1. Change DMA synchronization logic. 2. Terminate E45-12, -13 to +3 V. E L 7 Correct documentation errors. E M 8 Change R44 from 22n to 27n. Change R45 from 10n to 22n. C 01 ,E 1 9 Logic change implemented to inhibit BBS7 L during memory refresh. 0 F1,H1 Canceled by ECO 9A. E N C 0 E D2,E2 10 F2,H2 P Change 1. Logic change implemented to inhibit BBS7 L during memory refresh. 2. Removed scheme. OM A/refresh alternate cycle 3. Changed M7264-BB to -3.9 V LSI chips. 4. Documentation corrrected by ECOs 10A and 10B. E R 11 Created M7264-YB. E S 12 Phased out 23-001 C3 control chip and replaced it with 23-002C4. E T 13 Replaced 23-001B6 microm with 23-002B6. E u 14 1. Created M7264-CB, -DB. 248 M7264-XX Circuit Schematic/ECO History (Cont) Etch Rev CS Rev ECO No. E U 14 2. Operating frequency changed to 2.5 MHz min.-2.631 MHz max. E V 15 Routed IF CLR to pin AF 1 from CH 1. E W 16 Replaced 23-002B6 microm with 23-003B6. F V 17 1. Released etch Rev F. Change 2. Refresh 625 ± 20 Hz adjustment. 3. Pins 22 and 24 of E75 tied to phase 2 and phase 4 for WCS. 4. SRUN buffered to CH 1, AF 1. 5. BPOK line deglitched. 6. Chip set changes (see data sheets). 7. Documentation updated by ECO 17 A. C D3,E3 18 F3,H3 Added resistors R24, R25, R26, and R27 to D pull up BDAL 16 and BDAL 17 (formerly BAD 16 and BAD 17). This ECO is normally required in systems using DRV 11-Bs or MSV 11-Ds. F z 19 Created M7264-EB, -FB, -HB, and -JB. F AA 20 Create M7264-VC document changes. 1. Delete R50. 2. Add R60. F AB 21 Use 1611 H (21-15579-00) data chip instead of 1611 A (21-14549-01). Use 23003C3 control chip instead of 23002C4. Change R45 from 22Q to 15Q and clock frequency to 2.47 MHz for -VB and -BB only. 249 M7269 M7269 BUS INTERFACE FOR RKV11-D DISK DRIVE CONTROLLER Amps Bus Loads Cables +5 + 12 1.8max. 0 AC DC 1.93 (2) BC05L + M993- Y A Standard Address RKDS RKER RKCS RKWC RKBA RKDA RKDB (Drive Status) (Error) (Control/Status) (Word Count) (Bus Address) (Disk Address) (Data Buffer) 177400 177402 177404 177406 177410 177412 177416 Vector 220 Diagnostic Programs Refer to Appendix A. NOTE The logic test programs should be run first, then the dynamic test, and finally the performance exerciser. Related Documentation RKVII-D Disk Drive Controller User's Manual (EK-RKV11-0P-001) RKVII-Disk Drive Controller Technical Manual (EK-RKV11-TM-001) Field Maintenance Print Set (MP00223) RK05/RK05J/RK05F Disk Drive Maintenance Manual (EK-RK5JF-MM-00 1) RK05/RK05J Disk Drive Preventive Maintenance Manual (EK-RK05J-PM- 001) RK05F DEC Disk Drive Preventive Maintenance Procedure (ED-RK05F-PM- 001) Microcomputer Interfaces Handbook (EB-20 175-20) 250 M7269 c c 1 1 Jl J2 JUMPER SETTINGS INSTALLEO - Wl, W2, W3, W6, W7, Wll, W17 REMOVED - W4, W5, W8, W9, Wl0, W12, W13, W14, W15, W16 INTERRUPT VECTOR JUMPERS NOTE: NORMALLY INSTALLED JUMPERS ARE SHOWN AS SOLID LINES. 251 M7269 7 0 0 ~ .---~--~ ----~--- ---~~~--. ~ 15 14 13 12 11 10 09 08 07 06 05 04 03 I I I I I I I I I ::::~ULE ~ T wr wr TTTiT CONFIGURED ~ I ADDRESS (177400) I I I I R 02 01 00 I· INSTALLED R. REMOVED Wr R R R DEVICE ADDRESS MR-0803 I • INSTALLED R· REMOVED VECTOR ADDRESS MR-0804 Jumper settings on the three RKV 11-0 modules are identical to those in the standard RK 11-0 configuration. A breakdown is given below for reference. There are no jumpers on M7268. Module Installed Removed M7254 * M7255* * M7256 W1, W4, W6, W7 W1, W2, W6 W2, W5, W7 W2, W3, W5 W3, W4, W5 W1, W3, W4, W6, W8 Interrupt priority jumper (BR4-7) in socket E8 is not required since the RKV 11-0 was designed for only single-line interrupt scheme. 2.88 MHZ crystal used OEC PN 18-10694-3. 252 M7269 ~oW20 W7 0--0 M7254 253 M7269 W3 ~ W5 ~W6 W4 M7255 MR·08in 254 M7269 W1 00 W3 00 W4 roo W7 o W2 00 W8 o M7256 255 M7269 RKV 11-0 Module Utilization M7254 STATUS CONTROL M7255 DISK CONTROL M7256 DATA PATHS M7268 BUS ADAPTER H780POWER SUPPLY MR-0762 Drive Status Register (RKDS) Address = 177400 NOTE This register is a read-only register, and contains the selected drive status and current sector address. Bit Definitions Bit Function 00-03 Sector Counter (SC) - These four bits are the current sector address of the selected drive. Sector address 00 is defined as the sector following the sector that contains the index pulse. 04 Sector Counter Equals Sector Address (SC = SA) - Indicates that the disk heads are positioned over the disk address currently held in the sector address register. 05 Write-Protect Status (WPS) - Sets when the selected disk is in the write-protected mode. 06 Read/Write/Seek Ready (R/W /S ROY) - Indicates that the selected drive head mechanism is not in motion, and that the drive is ready to accept a new function. 07 Drive Ready (DRY) - Indicates that the selected disk drive complies with the following conditions. 256 M7269 Bit Definitions (Cont) Bit Function 1. 2. 3. 4. 5. 6. 7. The drive is properly supplied with power. The drive is loaded with a disk cartridge. The disk drive door is closed. The LOAD/RUN switch is set to RUN. The disk is rotating at a proper speed. The heads are properly loaded. The disk is not in a DRU (bit 10 or RKDS) condition. 08 Sector Counter OK (SOK) - Indicates that the sector counter operating on the selected drive is not in the process of changing, and is ready for examination. If this bit is not set, the sector counter is not ready for examination, and a second attempt should be made. 09 Seek Incomplete (SIN) - Indicates that due to some unusual condition, to seek function cannot be completed. Can be accompanied by RKER 15 (drive error). Cleared by a drive reset function. 10 Drive Unsafe (DRU) - Indicates that an unusual condition has occurred in the disk drive, and it is unable to properly perform any operations. Reset by setting the RUN/LOAD switch to LOAD. If, when the switch is returned to RUN, the condition recurs, an inoperative drive can be assumed, and corrective maintenance procedures should begin. Can be accompanied by RKER 15 (drive error). 11 RK05 Disk on Line (RK05) - Always set, to identify the selected disk drive as RK05. 12 Drive Power Low (DPL) - Sets when an attempt is made to initiate a new function, or if a function is actively in process when the control senses a loss of power to one of the disk drives. Can be accompanied by RKER 15 (drive error). Reset by a BUS INIT or a control reset function. 13-15 Identification of Drive (ID) - If an interrupt occurs as the result of a hardware poll operation, these bits will contain the binary representation of the logical drive number that caused the interrupt. 257 M7269 Error Register (RKER) Address = 177402 NOTE This is a read-only register. Bit Definitions Bit Function 00 Write Check Error (WCE) - Indicates that an error was encountered during a write check function as a result of a faulty bit comparison between disk data and memory data. Clears upon the initiation of a new function. This is a soft error condition. 01 Checksum Error (CSE) - Sets while performing a read function as a result of a faulty recalculation of the checksum. Cleared upon the initiation of any new function. This is a soft error condition. 02-04 Unused. The remaining bits of the RKER are all hard errors, and are cleared only by a BUS INIT or a control reset function. Bit Definitions Bit Function 05 Nonexistent Sector (NXS) - Indicates that an attempt was made to a sector address greater than 138 . 06 Nonexistent Cylinder (NXC) - Indicates that an attempt was made to initiate a transfer to a cylinder address greater than 312 8 . 07 Nonexistent Disk (NXD) - Indicates that an attempt was made to initiate a function on a nonexistent drive. 08 Timing Error (TE) - Indicates that a loss of timing pulses for at least 5 JiS has been detected. 258 M7269 Bit Definitions (Cont) Bit Function 09 Data Late (OL T) - Sets during a write or write check function when the multibuffer file is empty and the operation is not yet complete. Sets during a read function when the multibuffer file is filled and the operation is not yet complete. 10 Nonexistent Memory (NXM) - Sets if memory does not respond with a RPL Y within 20 jlS of the time when the RKV 11-0 becomes bus master during a OMA sequence. Because of the speed of the RK05 disk drive, it is possible that NXM will be accompanied by RKER 09 (data late). 11 Programming Error (PGE) - Indicates that RKCS 10 (format) was set while initiating a function other than read or write. 12 Seek Error (SKE) - Sets if the disk head mechanism is not properly positioned while executing a normal read, write, read check, or write check function. The control checks 16 times before flagging this error. A simple jumper change will force the control to check just once. 13 Write Lockout Violation (WLO) - Sets if an attempt is made to write on a disk that is currently write protected. 14 Overrun (OVR) - Indicates that during a read, write, read check, or write check function, operations on sector 138, surface 1 of cylinder address 3128 were finished, and the RKWC has not yet overflowed. This is essentially an attempt to overflow out of a disk drive. 15 Drive Error (ORE) - Sets if a function is either initiated or in process, and a. one of the drives in the system senses a loss of either ac or dc power; or b. the selected drive is not ready, or is in some error condition. 259 M7269 Control Status Register (RKCS) Address = 177404 UNUSED UNUSED CP·3139 Bit Definitions Bit Function 00 Go - This bit can be loaded by the operator and causes the control to carry out the function contained in bits 01-03 of the RKCS (functions). Remains set until the control actually begins to respond to go, which may take from 1 /-ts to 3.3 ms, depending on the current operation of the selected disk drive (to protect the format structure of the sector). Write only. 01-03 Function - The function register, or function bits, are loaded with the binary representation of the function to be performed by the control when a GO command is initiated. These bits are loaded by the program and cleared by BUS INIT. Read/write. The binary codings are as follows. 04, 05 Bit 3 Bit 2 Bit 1 Operation 0 1 0 1 0 1 0 0 0 0 0 0 () 1 0 0 Control Reset Write Read Write Check Seek Read Check Orive Reset Write Lock Unused. The RK 11-0 uses these bits. Since the POP-11 /03 bus structure has no provision for extended addressing, no connection is made to the bus from these bits on the RKV11-0. They will respond as two unused read/write bits in the status re~ister; but, like the RK 11-0 they, will increment should the RKBA overflow. 260 M7269 Bit Definitions (Cont) Bit Function 06 Interrupt on Done Enable (IDE) - When set causes the control to issue a bus request and interrupt to vector address 220 if: a. b. c. d. a function has completed activity a hard error is encountered a soft error is encountered and bit 08 of the RKCS (SSE) is set RKCS 07 (ROY) is set and go is not set. Read/write. 07 Control Ready (ROY) - Indicates that the control is ready to perform a function. Set by INIT, a hard error condition, or by the termination of a function. Cleared by go being set. Read only. 08 Stop on Soft Error (SSE) - If a soft error is encountered when this bit is set: a. all control action will stop at the end of the current sector if RKCS 06 (IDE) is reset, or b. all control action will stop and a bus request will occur at the end of the current sector if RKCS 06 (IDE) is set. Read/write 09 Unused. 10 Format (FMT) - FMT is under program control, and must be used only in conjunction with normal read and write functions. Used to format a new disk pack or to reformat any sector erased due to control or drive failure. Alters the normal write operation, under which the header is rewritten each time the associated sector is rewritten, in that the head position is not cbecked for proper positioning before the write. Alters the normal read operation in that only one word, the header word, is transferred to memory per sector. For example, a three-word read function in format mode will transfer header words from three consecutive sectors to three consecutive memory locations for software checking. Read/write. 11 Inhibit Incrementing the RKBA (IBA) - Inhibits the RKBA from incrementing during a normal transfer function. This allows data transfers to occur to or from the same memory location throughout the entire transfer operation. Read/write. 12 Unused. 261 M7269 Bit Definitions (Cont) Bit Function 13 Search Complete (SCP) - Indicates that the previous interrupt was the result of some seek or drive reset function. Cleared at the initiation of any new function. Read only. 14 Hard Error (HE) - Sets when any of RKER 05-15 are set. Stops all control action, and processor reaction is dictated by RKCS 06 (IDE), until cleared, along with RKER 05-15, by INIT or a control reset function. Read only. 15 Error (ERR) - Sets when any bit of the RKER sets. Processor reaction is dictated by RKCS 06 and RKCS 08 (IDE and SSE). Cleared if all bits in the RKER are cleared. Read only. Word Count Register (RKWC) Address = I 15 WC16: · 177406 14 12 ; 10 09 07 08 08 05 ; : 04 03 02 01 :wcoo : : I CP-3140 Bit Definition Bit 00-15 Function WCOO-WC15 - The bits in this register contain the 2's complement of words to be affected or transferred by a given function. The register increments by 1 after each word transfer. When the register overflows (all WC bits go to 0), the transfer is complete and RKV 11-0 operation is terminated at the end of the present disk sector. However, only the number of words specified in the RKWC are transferred. Read/write. Current Bus Address Register (RKBA) Address = 177410 13 Bit 00-15 09 08 07 05 04 03 02 01 Bit Definition Function BAOO-BA 15 - The bits in this register contain the bus address to or from which data will be transferred. The register is incremented by two at the end of each transfer. Read/write. 262 M7269 Disk Address Register (RKDA) Address = 177412 NOTE This register will not respond to commands while the controller is busy_ Therefore, RKDA bits are loaded from the bus data lines only in the control ready (ROY - bit 07 of the RKCS) state, and are cleared by BUS INIT and control reset. The RKDA is incremented automatically at the end of each disk sector. Bit Definitions Bit Function 00-03 Sector Address (SA) - Binary representation of the disk sector to be addressed for the next function. The largest vaJid address (or number) for the sector address is 138 . 04 Surface (SUR) - When set, enables the lower disk head so that operation is performed on the lower surface; when reset, enables the upper disk head. 05-12 Cylinder Address (CYL ADDR) - Binary representation of the cylinder address currently being selected. The largest valid address or number for the cylinder address is 312 . 13-15 Drive Select (DR SEL) - Binary representation of the logical drive number currently being selected. 263 M7269 Data Buffer Register (RKDB) Address = 177416 10 : : : : 09 DB 07 06 (15 04 03 02 01 : : : : : : Bit Definition Bit Function 00-15 D800-D815 - The bits of this register work as a general data handler in that all information transferred between the control and the disk drive must pass through this register. Loaded from the bus only while the RKV 11-0 is bus master during a OMA sequence. Read only. NOTE Address 177414 is unused. 264 M7269 TOM993·YA tRK05} TO M7269 tLSI·" BUS} M7268 M993·YA TOP GROOVE ~ ~~----------------------~~'=::JD30WN \-CTJ ~ TOP~I____________________~ M7268 M7259 ~--------~~-.~~ TOP GROOVE SIDE BC05L BC05L TOP~ __________________ ~ MR·0763 RKV 11-0 Cable Connection 265 M7270 M7270 LSI-11/2 PROCESSOR MODEL DESIGNATIONS KD11-HA KD11-HB KD11-HC KD11-HD KD11-HF KD11-HJ KD11-HU Dual-height LSI-11 processor without memory KD 11-HA + MSV 11-DB 8K word memory KD 11-HA + MSV 11-DC 16K word memory KD 11-HA + MSV 11-00 32K word memory KD 11-HA + MSV 11-DA 4K word memory KD 11-HA + MMV 11-A 4K word core memory KD11-HA + MRV11-BA KD11-XA KD11-XB KD11-XC KD11-XD KD11-XH KD11-XJ KD 11-HA, 2 MSV 11-ED 64K word memory KD 11-HA, 4 MSV 11-ED 128K word memory KD 11-HA, 9 MSV 11-ED 288K word memory KD11-HA, 3 MSV11-DD KD11-HA, 3 MSV11-DC KD11-HA, 3 MSV11-DB M7270 Specifications Size: Double-height module Dimensions: 13.34 cm (5.25 in) X 22.8 cm (8.9 in) Power: +5 Vdc ±5%, 1 A + 12 Vdc ± 5%, .22 A Bus Loads: AC - 1.7 unit loads DC - 1 unit load Related Documentation Microcomputer Processor Handbook (EB-18451-20) KD 11-HA Print Set (MP-00495) LSI-11 Maintenance Card (EK-LSI11-MC) 266 (Heathkit) (Heathkit) (Heathkit) (Heathkit) (Heathkit) (Heathkit) M7270 EVNTINTERRUPT INSTALLED DISABLE REMOVED = ENABLE W3 Wl >(KEVll OP~~6N SOCKETlI \> MASTER CLOCK ENABLE (ALWAYS INSTALLED) MICROM 1 12 MICROM 0 12 CONTROL I? DATA PATH ~~}- .------------------------~ POWER·UP MODE SELECT NOTE TO DISABLE WAKEUP CIRCUIT, REMOVE CAPACITOR Cl WHEN USED WITH SEQUENCER POWER SUPPLIES. (BAll·MAND BAll·N) M7270 Jumpers and Socket Locations 267 M7270 Jumper W1 Always installed - master clock enabled. W3 Removed - external event interrupt (line clock) enabled. Installed - external event interrupt disabled. W6 W5 Mode Selected PC at 24 and PS at 26, or halt mode (mode 0). ODT microcode (mode 1). PC at 173000 for user bootstrap (mode 2). Special processor microcode; not implemented (mode 3). R· R R R I I R I Diagnostic Programs The following diagnostic programs are for use with LSI-11 processors except for the limitations noted. VKAA?? LSI-11 basic instruction test. VKAB?? LSI-11 Extended Instruction Set (EIS) test. This program can be run only on LSI-11 CPUs with the KEV 11 (EIS/FIS) or KEV 11-CA (DIBOL instruction set) options installed. . VKAC?? LSI-11 Floating Point Instruction (FIS) test. This runs only on LSI-11 CPUs that have the KEV 11 (EIS/FIS) option (23-00385). VKAD?? LSI-11 traps test. This diagnostic auto-sizes for the EIS, FIS, and DIBOL options. a. Older versions (Rev B 1 and below) require the setting of a bit in the software switch register if EIS, FIS, or OIBOL is present. b. Rev A diagnostics will not run on 0322 or 0324 systems because of the DIS instructions. NOTE See Appendix A for XXDP + multimedia assignments. VKAH?? Basic system exerciser. Tests serial line unit, memory, processor, EIS/FIS, clock, and both floppy disks under various conditions. Software switch register must be set for options. • R = jumper removed; I = jumper installed. 268 M7270 Chip Vendor Number DEC Number Vee DATA CP 16118-39 CONTROL MICROM-O MICROM-1 CP 1621 8-173 CP 16318-103 CP 1631 8-073 2 1-11549-01 21-15579-00 23-002C4 23-00185 23-00285 -3.9 -3.5 -3.9 -3.9 -3.9 EIS/FIS (if present) KEV11-A CP 1631 8-135 23-00385 -3.9 Comments With ECO 6 2007 pattern ECOs for Etch Rev E CS Rev ECO No. A Change 1. Remove blanking pulse. 2. Generate clock driver Vee from + 12 V. 3. Move K 1 MST8 L from E34-3 to E34-4. 4. Relayout board. 8 2 Change C31 10- 10279-0. and C32 from C 3 Change Augat socket to 8urndy socket. F 3A Allow customer to remove C81. H 4 Change R18 from 13-10317 to 13-10522. J 5 Alternate part 19-14282-01 may be used to replace E37. K 6 Change part E30 from 21-11549-01 to 21-15579-00. 269 10-12312-01 to M7940 M7940 DLV11 SERIAL LINE UNIT Amps Bus Loads +5 + 12 1.0 (1.6 max.) 0.18 (0.25 max.) AC 2.48 Cables DC BC05M for 20 rnA BC05C for Bell 103 modem and EIA Be05C plus H312A or H308 for EIA terminal Standard Addresses RCSR RBUF XCSR XBUF Console Second Terminal Modem (Auto Mode) 177560 177562 177564 177566 176500 176502 176504 176506 175610 175612 175614 175616 Vectors Receiver Interrupt Transmitter Interrupt Console Second Terminal Modem 60 64 300 304 300 304 Diagnostic Program Refer to Appendix A. 270 M7940 NOTE The DECX module DLA? requires a wraparound connector to run. The connector is not available and must be made up from the following parts: Berg connector Berg pins No. 22 AWG wire PN 12-10918-15 PN 12-10089-07 PN 90-07350-00. Connect the following pins: F to J M to E Related Documentation Field Maintenance Print Set (MP00055) Microcomputer Interfaces Handbook (EB-20175-20) 271 M7940 TP1 i •• J •• ,'T·, TP2 b « H INSERT .005J..1F CAPACITOR (PN10·01765) WHEN THE SERIAL LINE DEVICE IS A TE LETYPEWR ITE R (L T33 OR L T35) I.LI I'-UlIOVIfl >_NID 1.LI1D1D1f)1L »»> ILZZNZ II111 11111 1111111111 GlOlO:;::N «««« ««;;(<(<( IflVIOUI ::r I.LI 10.. CP- leol 272 BDAl BITS ..-:1=-5__r_-------r------~.:..-----_r_-----__r_-------':......., I I 1 I 1 I I '-----------... BBS7l ' l(U ~ ~ q: ~ ~ ~ ~ ~ ~ : ADDRESS JUMPERS: IN STA llED ,0 REMOVED' 1 lJl X I O~ CSR } 1 - DATA BUFFER ~: ~~~~I~~~TER (PART OF FUNCTION DECODING) RANGE' 160000. -177776. DL V 11 Address Bits BDAl BITS 8 15 0 0 0 0 0 0 0 7 0 0 0 I I"- ,> I <D > I II'l > I <t > VECTOR JUMPERS: INSTAllED=O REMOVED = 1 I r<l > 1 I 0 L 0 = RECEIVER 1 = TRANSMITTER RANGE =0- 3748 Cp-1803 DL V 11 Interrupt Vector Bits M7940 DLV11 SLU Factory Jumper Configuration Jumper Designation Jumper Status A3 A4 A5 A6 A7 A8 A9 A10 A 11 A12 I R R R I R R R R R This arrangement of jumpers A3 through A 12 implements the octal device address 17756X, which is the assigned address for the console device SLU. The least significant digit is hardwired on the module to address the four SLU device registers as follows: V3 V4 V5 V6 V7 I R R I I This jumper arrangement implements the interrupt vector addresses 60 for received data and 64 for transmitted data. NP 2SB NB2 NB1 R R R R No parity. Two stop bits (installed on 0322 and 0324). Eight data bits. PEV FEH R I EIA R Even parity if NP installed. Halt on framing error (removed on 0322 and 0324). 12 V EIA operation disabled (installed on 0322 and 0324). FRO FR1 FR2 FR3 R R R R CL1 Function x = 0, RCSR address X = 2, Receive data register address X = 4, XCSR address X = 6, Transmit data register address. 110 baud rate selected. 20 rnA current loop active receiver and transmitter selected. CL2 CL3 CL4 274 M7940 Number of Data Bits 5 6 7 8 NB1 NB2 Installed Removed Installed Removed Installed Installed Removed Removed Number of Stop Bits Transmitted 2SB installed = one stop bit. 2SB removed = two stop bits. Parity Transmitted NP removed = no parity bit. NP and PEV installed = odd parity. NP installed and PEV removed = even parity. Framing Error FEH installed = halt on framing error (console). FEH removed = do not halt on framing error. Unit Address Jumpers Address A12 A11 Console 177560 First Option 176500 Second Option 176510 Third Option 176520 175610 Modem Unit Console First Option Second Option Third Option Modem Vector 60 300 310 320 300 R R R R R R R R R R A10 A9 A8 A7 A6 A5 A4 A3 R R R R I R I I I R I I I I R R R R R R R R R R I R I I I I R I I R I I I R I R Vector Jumpers V7 V6 V5 V4 V3 I R R R R I R R R R R I I I I R I I R I I I R I I 275 ~ M7940 Baud Rate Selection Baud Rate FR3 FR2 FR1 FRO 50 75 110 134.5 150 200 300 600 1200 1800 ·2400 ·2400 4800 9600 I I I I R R R I R R R R R R R R R R R I I I R R I R I R R R R I I R I I I I R R I R R R R I I I R I R I R I • Either configuration may be used. Use second configuration for D322 and D324. :! w o o Active transmit = CL3 and CL4 installed. Active receive = CL 1 and CL2 installed. NOTE CL2 and CL3 are 180 Q resistors. 276 M7940 USE BC05M CABLE L-.-r~-==~_1 ~ Hj y-6-1] .. 0 \ 00 o o Passive transmit = CL3 and CL4 as in preceding figure. Passive receive = CL 1 and CL2 as in preceding figure. NOTE When configured for passive operation, the (+) and (-) lines are reversed. Use a BC05F cable. USE BCOlv OR BC05C CABLE I Jumper EIA must be inserted for EIA operation. Jumpers CL 1 through CL4 do not have to be removed when EIA is inserted. RECE IVER INTERRUPT ENABL E (READ/WRITE) Receiver Control/Status Register (RCSR) 277 M7940 RCSR Bit Definitions Bit Function 15 Dataset Status - Set when CARRIER or CLEAR TO SEND and DATA SET READY signals are asserted by an EIA device. Readonly. 14-08 Not used. Read as O. 07 Receiver Done - Set when an entire character has been received and is ready for input to the processor. This bit is automatically cleared when RBUF is addressed or when the BDCOK H signal goes false (low). A receiver interrupt is enabled by the DL V 11 when this bit is set and receiver interrupt is enabled (bit 6 is also set). Read-only. 06 Interrupt Enable - Set under program control when it is'desired to generate a receiver interrupt request when a character is ready for input to the processor (bit 7 is set). Cleared under program control or by the BINIT signal. Read/write. 05-01 Not used. Read as O. 00 Read Enable - Set by program control to advance the paper tape reader on a teletypewriter device to input a new character. Automatically cleared by the new character's start bit. Write only. 15 (NOT USED) DATA AND PARITY (5-7 BIT DATA IS RIGHT JUSTIFIED. PARITY IS BIT 7. NO PARITY BIT IS PRESENT WHEN 8-BIT DATA IS USED.I Receiver Buffer Register (RBUF) RBUF Bit Definitions Bit Function 15-08 Not used. Read as 0, 07-00 Contains five to eight data bits in a right-justified format. MSB is the optional parity bit. Read only. 278 M7940 XCSR TRANSMIT INTERRUPT ENABLE (READ/W RITE) Transmitter Control/Status Register (XCSR) XCRS Bit Definitions Bit Function 15-08 Not used. Read as O. 07 Transmit Ready - Set when XBUF is empty and can accept another character for transmission. It is also set during the powerup sequence by the BOCOK H signal. Automatically cleared when XBUF is loaded. When transmitter interrupt is enabled (bit 6 also set), an interrupt request is asserted by the OL V 11 when this bit is set. Read only. 06 Interrupt Enable - Set under program control when it is desired to generate a transmitter interrupt request when the OL V 11 is ready to accept a character for transmission. Reset under program control or by the BINIT signal. Read/write. 05-01 Not used. Read as O. 00 Break - Set or reset under program control. When set, a continuous space level is transmitted. BINIT reset this bit. Read/write. 15 XBUF~I ~ ~~~~ ~ ~ ~ ~~ ~ ~ ~ ~~ ~ ~ __ __ __ __ __ __ __ __ __ __ __ __ ~ •• ----~---------------"---------- (NOT USED) DATA Transmitter Buffer Register (XBUF) XBUF Bit Definitions Bit Function 15-08 Not used. 07-00 Continuous five to eight right-justified data bits. Loaded under program control for serial transmission to a device. Write only. 279 M7941 M7941 DRV11 PARALLEL LINE UNIT Amps +5 0.9 (1.6 max.) Bus Loads + 12 0 AC 2.80 DC 1.0 Cables (2) BC07D (2) BC08R Standard Addresses DRCSR DROUTBUF DRINBUF First Device Second Device MINC/ DECLAB 167770 167772 167774 167760 167762 167764 171770 171772 171774 300, 304 310 314 370 374 Vectors Interrupt A Interrupt B Diagnostic Programs Refer to Appendix A. NOTE Full testing requires a BC08-R wraparound cable for VKAF?? and ORA? Related Documentation ADVll-A, KWVll-A, AAVll-A, DRVll User's Manual (EK-ADV11-0P) Field Maintenance Print Set (MP00054) Microcomputer Interfaces Handbook (EB-20 175-20) 280 M7941 c c U J1 U J2 I V~;R--:U-;;~--' I I I V4---VS I I I I I I V3---V6 I L ___ -:::-:..V?J i ~DDRESS:;UMPERS- i I I A3-A4-- --A9 --Al0 SLl \, SL2 o---7t---o I I :LA...!=-::. H= _____ ==ta:...J OPTIONAL EXTERNAL CAPACITOR "R-oaoe 281 M7941 I ~--' I I ~ BBS7 L "!L1 ~: 4 ~ ~ ~ ~ ~ ~----------------.-.-~~----~~----.---' ADDRESS JUMPERS 'NSTALLED -0 REMOvED " L I L BYTE SELECT "h,qhbY'.!S-'51 0, 'ow by'.! 0 -7 I REGISTE R OOX ' DRCSR 0' X - DROUTBUF 'OX'DR'NBUF , , X ' NO RESPONSE '5 ~ ~ J h1 L ~-------' (DRCSR-151 REQUEST I NG DEVICE 0' REQ A 1 • REO B VECTO R JUMPERS: INSTALLED·O REMOVED -, DRV11 PLU Factory Jumper Configuration Jumper Designation Jumper State A3 A4 A5 A6 A8 A9 A10 A 11 A12 R R R R R R R R I I This arrangement of jumpers A3 through A 12 assigns the device address 16777X to the PLU. This address is the starting address of a reserved block in memory bank 7 which is recommended for user device address assignments. The least significant digit X is hardwired on the module to implement the -three PLU device addresses as follows: V3 V4 V5 V6 V7 I I I R R This factory-installed jumper configuration implements the two interrupt vector addresses 300 and 304 for use as defined by application requirements. SL1 SL2 R R These jumper posts are provided for the installation of an external capacitor. A7 Function X = 0, DRCSR address X = 2, Output buffer address X = 4, Input buffer address. 282 M7941 External Capacitor The pulse width of NEW DATA READY and DATA TRANSMITTED may be modified by installing an external capacitor. Note that the trailing edge of one of these two pulses must be used to clear interrupt requests. Capacitor (}1F) Pulse Width (ns) None (as shipped) 350 750 1550 2330 3150 .0047 .01 .02 .03 NOTE Any system containing a REV11 and a DRV11 that has a capacitor to extend NEW DATA READY and DATA TRANSMITTED greater than 1800 ns may cause the REV 11 to hang the system unless the REV 11 is at ECO 5 level or greater (Circuit Schematic Rev K). DRCSR CSRO (READ/WRITE) Control/Status Register DRCSR Bit Definitions Bit Function 15 REQUEST B - This bit is under control of the user's device and may be used to initiate an interrupt sequence or to generate a flag that may be tested by the program. 14-08 Not used. Read as O. 07 REQUEST A - Performs the same function as REQUEST B (bit 15) except that an interrupt is generated only if INT ENB A (bit 06) is also set. When the maintenance cable is used, the state of REQUEST A is identical to that of CSRO (bit 00). Cleared by INIT when in maintenance mode. Read-only. 283 M7941 DRCSR Bit Definitions (Cont) Bit Function 06 INT ENB A - Interrupt enable bit. When set, allows an interrupt request to be generated, provided REQUEST A (bit 07) becomes set. 05 INT ENB B - Interrupt enable bit. When set, allows an interrupt sequence to be initiated, provided REQUEST B (bit 15) becomes set. 04-02 Not used. Read as o. Can be loaded or read by the program. Cleared by INIT. Read/write. 01 CSR 1 - This bit can be loaded or read (under program control) and can be used for a user-defined command to the device (appears only on connector no. 1). When the maintenance cable is used, setting or clearing· this bit causes an identical state in bit 15 (REQUEST B). This permits checking operation of bit 15 which cannot be loaded by the program. Can be loaded or read by the program. Cleared by INIT. Read/write. 00 CSRO - Performs the same functions as CSR 1 (bit 01) but appears only on connector no. 2. When the maintenance cable is used, the state of this bit controls the state of bit 07 (REQUEST A). Cleared by INIT. Read/write. DROUTBUF o 15 DATA OUT (R EADI WRITE) MR-Oatt Output Data Buffer Register (DROUTBUF) DROUTBUF Bits 15-00 Output Data Buffer - Contains a full 16-bit word or one or two 8-bit bytes: high byte = 15-8; low byte = 7 -0. Loading is accomplished under a program-controlled DATO or DATOB bus cycle. It can be read under a program-controlled DATI cycle. 284 M7941 DRIN8UF o 15 DATA IN (READ ONLY) Input Data Buffer Register (DRINBUF) DRINBUF Bits 15-00 Input Data Buffer - Contains a full 16-bit word or one or two 8-bit bytes. The entire 16-bit word is read under a program-controlled DATI bus cycle. 285 M7942 M7942 MRV11-AA READ-ONLY MEMORY Amps WIO PROMs (0.6 max.) With PROMs (4.1 max.) +5 0.4 -12 0 2.8 0 Bus Loads Cables AC 1.84 none DC 1.0 Standard Addresses Module is shipped with all jumpers installed, selecting bank 0 addresses (0-1777). Vectors, Diagnostic Program, Exerciser Program None Related Documentation Field Maintenance Print Set (MP00066) Microcomputer Processor Handbook (EB-18451-20) NOTES 1. Jumpers W8-W14 select chip set types (512 or 256). 2. Any row not populated with PROMs must have the BRPL Y L jumper (WO-W7) removed. 286 M7942 MRV11-AA Address Word Formats Bank Select Bank W15 W16 W17 0 I I I I I I I R R I R R R R I I R R R R 2 3 4 5 6 7 R R ~ ~ NOTE Because of addressing limitations, this module is not compatible with PDP-11/23 systems with more than 64K bytes of memory. 512X4 PROM/ROM CHIPS ~15~ I I ________~______~________. -______~______~ I I '-;".........""'7""""'-7-':::======::':==~=======::'::::::711 W~5 4096 - LOCATION ADDRESS BYTE W16 (WB-W10 INSTALLED; W11-W14 REMOVED) POINTER I wh ~ 4K ADDRESS SPACE JUMPERS 15 256 X 4 PROM/ROM CHI PS '----.l...--"-----'-""T""".l---'---.l---'---"'----'-__-'----'-__-'----'-__-'-----'-~ W16 ~ 4K ADDRESS SPACE JUMPERS HIGH/LOW 2K SELECT W13 INSTALLED: LOW 2K (0-7777) W14 INSTALLED: HIGH 2K (1000-17777) MRV 11-A Address Word Format 287 M7942 12-15 8-11 4-7 3-0 c=J c=J F I CE7 c=J ~ § I CE6 c=J c=J F I CE5 c=J c=J P I CE4 c=J c=J E I CE3 c=J c=J L=:==J CE2 c=J c=J p i C E 1 c=J c=J F I CEO L--------l L-------.-I L-------.-I L-------l L-P L-P _-----1 _-----1 L--------l L--.-----l M7942 ETCH REV. 0 M7942 Etch Rev D 288 M7942 512 by 4-Bit PROM Addresses Bank Address Jumpers W15 W16 W17 I I I I I I I R R I R R R R I I I R R I R R R R Word/Byte Address Physical Row BRPLY L Jumper 0-1777 2000-3777 4000-5777 6000-7777 10000-11777 12000-13777 14000-15777 16000-17777 CEO CE1 CE2 CE3 CE4 CE5 CE6 CE7 WO W1 W2 W3 W4 W5 W6 W7 256 by 4-Bit ROM Addresses Bank Address Jumpers Word/Byte Address W15 W16 W131nstalled W17 W14 Removed W13 Removed W14 Installed Physical BRPLY L Row Jumper I I I I I I R R R R R R R R I I I R R I 0-7776 10000-17776 20000-27776 30000-37776 40000-47776 50000-57776 60000-67776 70000-77776 100000-107776 110000-117776 120000-127776 130000-137776 140000-147776 150000-157776 160000-167776 170000-177776 CEO CE2 CE4 CE6 CE1 CE3 CE5 CE7 I I R R BRPL YL Select Empty Row Remove Jumper CEO CE1 CE2 CE3 CE4 CE5 CE6 CE7 WO W1 W2 W3 W4 W5 W6 W7 289 WO W2 W4 W6 W1 W3 25 W7 M7944 M7944 MSV11-B READ/WRITE MEMORY Amps +5 + 12 0.6 (1.12 max.) 0.3 (0.7 max.) Bus Loads Cables AC DC 1.89 1.0 none Standard Addresses Module is shipped with all jumpers installed, selecting bank 0 (0-17776). Vectors, DEC/X 11 Exerciser Program None Diagnostic Programs Refer to Appendix A. Related Documentation Field Maintenance Print Set (MP00067) Microcomputer Processor Handbook (EB-18451-20) NOTES 1. Only one dynamic memory module in a system is needed to reply to the refresh bus functions initiated by the processor. The module selected should be the one with the longest access time (usually the module electrically farthest from the refreshing device). 290 M7944 NOTES (Cont) 2. If a REV11 (M9400YA or YC) provides refresh, only the processor-resident memory (if present) should reply to refresh. If the processor board has no resident memory, the memory module electrically farthest from the REV11 should reply. 3. Refer to the Refresh Configuration Procedures in the 1/ Systems Configurations" section. '<t~ s:s: 1111 M7944 ETCH REV B M7944 Etch Rev B 291 M7944 BDAL BITS 15 13 o 12 4096 LOCATION ADDRESS Wl W2 W3 BYTE POINTER 4K ADDRESS SPACE JUMPERS / Bank WI W2 NOTE: W3 No. I:: Installed, Address Range Octal Address RAnge OAK 48K a·12K 12·16K 16·20K 2O·24K 2428K 28·32K 000000·017776 020000·037776 040000·057776 060000·077776 100000·117776 120000·137776 140000·157776 160000·177 776 A = Removed MR·5429 MSV 11-8 Address Format! Jumpers NOTE Because of addressing limitations, this module is not compatible with PDP-11 /23 systems with more than 64K bytes of memory_ MSV11-B Address Format/Jumpers Reply to Refresh Function W4 Reply Don't reply R I 292 M7946 M7946 RXV11 FLOPPY DISK INTERFACE Amps +5 1.5 max. + 12 0 Bus Loads Cables AC 1.74 BC05L DC Standard Addresses RXCS RXDB Vector First Device Second Device 177170 177172 264 177150 177152 270 Diagnostic Programs Refer to Appendix A. NOTE Run DZRXB before DZRXA. Related Documentation RXV11 User's Manual (EK-RXV11-0P-001) Field Maintenance Print Set (MP00024) Microcomputer Interfaces Handbook (EB-20 175-20) 293 3: ...... co ~ 0 0 0 I' 1 0 0 0 0 1 C _WI _w> Wl _ _ _ _ _ _ W3 W2 ........... _____ ws w.e...-..... ....-....W6 _ _ _ W13 WB.....-4 _____ W14 W16 .......... _ _ _ wg _W4 _ws _ _ W1 W1~ _we W10 _ _ _ _ _ _ W17 W l 1 - - " _ _ _ W15 ......--.Wl1 ____ W12 ETCH REV B . MACHINE INSERTED JUMPERS W13 .......... ....._W16 W1 ........... ....._W17 ETCH REV C· WIRE·WRAP JUMPERS 0 -8-. 0) DEVICE ADDRESS FACTORYCONFIGURED _ _ R ADDRESS RXCS' 177170 RXDB'I77172 Device Address I\) <0 01 DAL BITS_15 VECTOR ADDRESS I I : 0 0 00 07 0 : 0 I 0 : 0 : 0 I 0 .JUMPER ON _ M7946 MODULE : 0 I I I I I I I I I I I I W6 FACTORY-CONFIGURED - R VECTOR ADDRESS=264 W5 W4 W3 W2 WI R R I R : 0 I NOTE: 1= Jumper inslalled' Logical" R' Jumper removed = Logica I 1 X' Don'l care MR-OBI4 Vector Address Unit Address Address Jumpers W17 W16 W15 W14 W13 W12 W11 W10 W9 W8 First 177170 (Drives 0, 1) R R R R R R R Second 177150 (Drives 2, 3) R R R R R R Unit Vector R R Vector Jumpers W6 W5 W4 W3 First 264 (Drives 0, 1) R R R Second 270 (Drives 2, 3) R R R W2 W1 R R W7 M7946 NOTES 1. When inserting the cable in the RXV11 interface module, the red edge of the cable should be at the center of the module (near the pin A end of J 1). 2. BUS INIT - Install W18 to pass bus INIT to the RX01 as initialize. 15 14 13 12 11 10 09 07 OS 1 I ERROR NOT USED I TR RX INIT 05 06 I I I I DONE lNT ENB 04 03 I I 01 02 I I 00 I I ~ I UN1T SEL FUNCTION ~ 000 001 010 011 100 101 110 11, I GO FILL SUFFER EMPTY BUFFER WRITE SECTOR READ SECTOR NOT USED READ STATUS WRITE DELETED DATA SECTOR READ ERROR REGISTER Receiver Control/Status Register (RCSR) Bit Definitions Bit Function o Go - Initiates a command to RXO 1. Write only. 1-3 Function Select - These bits code one of the eight possible functions. Write only. 4 Unit Select - This bit selects one of the two possible disks for execution of the desired function. Write only. 5 Done - This bit indicates the completion of a function. Done will generate an interrupt when asserted if interrupt enable (RXCS bit 6) is set. Read only. 6 Interrupt Enable - This bit is set by the program to enable an interrupt when the RXO 1 has completed an operation (done). The condition of this bit is normally determined at the time a function is initiated. This bit is cleared by the LSI-11 bus initialize (BINIT L) signal, but it is not cleared by the RXV 11 initialize bit (RXCS bit 14). Read/write. 297 M7946 Bit Definitions (Cont) Bit Function 7 Transfer Request - This bit signifies that the RXV 11 needs data or has data available. Read only. 8-13 Unused. 14 RXV 11 Initialize - This bit is set by the program to initialize the RXV 11 without initializing all of the devices on the LSI-11 bus. Write only. CAUTION 1. Loading the lower byte of the RXCS will also load the upper byte of the RXCS. 2. Setting this bit (BIS instruction) will not clear the interrupt enable bit (RXCS bit 06). Upon setting this bit in the RXeS, the RXV 11 will negate done and move the head position mechanism of drive 1 (if two are available) to track O. Upon completion of a successful initialize, the RXO 1 will zero the error and status register, set initialize done, and set RXES bit 7 (DRV RDY) if unit 0 is ready. It will also read sector 1 of track 1 and drive o. 15 Error - This bit is set by the RXO 1 to indicate that an error has occurred during an attempt to execute a command. This readonly bit is cleared by the initiation of a new command or by setting the initialize bit. When an error is detected, the RXES is automatically read into the RXDB. The RXDB register serves as a general purpose data path between the RXO 1 and the RXV 11 interface. It may represent one of five RXO 1 registers according to the protocol of the command function in progress. The RXO 1 registers include RXDB, RXTA, RXSA, RXES, and RXER. CAUTION Violation of protocol in manipulation of this register may cause permanent data loss. Refer to RXV11 User's Manual. 298 M7946 RXDB-RX Data Buffer - All information transferred to and from the floppy media passes through this register and is addressable only under the protocol of the function in progress. 15 14 13 12 II 10 09 08 07 06 05 04 03 02 0I 00 ----v NOT USED READ/WRITE DATA RXDB Format RXTA-RX Track Address - This register is loaded to indicate on which of the 114 tracks a given function is to operate. It can be addressed only under the protocol of the function in progress. Bits 8 through 15 are unused and are ignored by the control. 15 14 13 12 11 10 09 08 07 06 05 04 I I 03 02 01 00 0 i ~--------~i--------~ NOT USED 0-114. RXTA Format RXSA-RX Sector Address - This register is loaded to indicate on which of the 32 sectors a given function is to operate. It can be addressed only under the protocol of the function in progress. Bits 8 through 15 are unused and are ignored by the control. 15 14 13 12 11 10 09 08 07 06 05 04 03 0:.1 01 00 I I I I 0 0 0 L - -_ _ _ _ _ _~--------~ NOT USED RXSA Format RXES-RX Error and Status - This register contains the current error and status conditions of the drive selected by bit 4 (unit select) of the RXCS. This read-only register can be addressed only under the protocol of the function in progress. The RXES is located in the RXDB upon completion of a function. 15 14 13 12 11 . 10 09 08 07 I~~~ I 06 DD 05 04 . NOT USED NOT USED RXES Format 299 03 M7946 RXDB Bit Definitions Bit Function o CRC Error - A cyclic redundancy check error was detected as information was received from a data field of the diskette. The RXES is moved to the RXDB, and error and done are asserted. Parity Error - A parity error was detected on command or on address information being transferred to the RXO 1 from the LSI-11 bus interface. A parity error indication means that there is a problem in the interface cable between the RXO 1 and the interface. Upon detection of a parity error, the current function is terminated; the RXES is moved to the RXDB, and the error and done are asserted. 2 Initialize Done - This bit is asserted in the RXES to indicate completion of the initialize routine, which can be caused by RXO 1 power failure, system power failure, or programmable or LSI-11 bus initialize. 3-5 Unused. 6 Deleted Data Detected - During data recovery, the identification mark preceding the data field was decoded as a deleted data mark. 7 Drive Ready - This bit is asserted if the unit currently selected exists, is properly supplied with power, has a diskette installed correctly, has its door closed, and has a diskette up to speed. NOTES 1. The drive ready bit is valid only when retrieved via a read status function or at completion of initialize when it indicates status of drive O. 2. If the error bit was set in the RXCS but error bits are not set in the RXES, then specific error conditions contained in the RXER can be accessed from the RXDB via a read error register function. RXER-RX Error - This register is located in the RXO 1 and contains specific RXO 1 error information. This information is normally accessed when the RXCS error bit 15 is set but RXES error bits 0 and 1 are not set. This is e read-only register. 300 M7946 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 ~------~~----------~ NOT USED RXER Format Octal Code Error Code Meaning 0010 0020 0030 0040 0050 0060 0070 Drive 0 failed to see home on initialize. Drive 1 failed to see home on initialize. Found home when stepping out 10 tracks for INIT. Tried to access a track greater than 77. Home was found before desired track was reached. Self-diagnostic error. Desired sector could not be found after looking at 52 headers (two revolutions). More than 40 microseconds and no SEP clock seen. A preamble could not be found. Preamble found but no I/O mark found within allowable time span. eRe error on a header; no flag. The header track address of a good header does not compare with the desired track. Too many tries for an 10 address mark. Data mark not found in allotted time. eRe error on reading the sector from the disk. No code appears in the ERREG. Parity error on some word from interface. 0110 0120 0130 0140 0150 0160 0170 0200 0210 301 M7948 M7948 DRV11-P FOUNDATION MODULE Amps Bus Loads DC +5 +12 AC 1.0 2.08 1.0 Plus user's logic Cables BC07A BC07D BC08R BC04Z Standard Addresses No standard designated. Configurable within the range of 760000- 777776. May conflict with DEC standard device addresses. Vectors None assigned. Configurable within the range of 0-374. May conflict with DEC standard device vectors. Diagnostic Program None Related Documentation DRVll-P Foundation Module User's Manual (EK-DR 11-0P) Field Maintenance Print Set (MPOO 119) Microcomputer Interfaces Handbook (EB-20 175-20) 302 +5V WIRE-WRAP PIN UPPER RIGHT PIN OF FIRST FIVE MOUNTING AREAS GROUND WIRE-WRAP PIN UPPER LEFT PIN OF FIRST FIVE MOUNTING AREAS FH JK •• • LM ~ o ::: WIRE-WRAP PINS FOR INTERCONNECTING USERIC'S .~ '"o ~ N <0 ... . ", ':11: rt)lLJ •• ~. • ii ii 1 -i~-- h-l 4 +5V WIRE-WRAP PIN LOWER RIGHT PIN OF All MOUNTING AREAS. DESIGNATED BY PLUS (+) SIGN. GROUND WIRE-WRAP PIN LOWER lEFT PIN OF All MOU"ITiNG AREAS. DESIGNATED BY MINUS (-) SIGN. +- REMOVE TO DISABLE VECTOR ADDRESSING (SEE TEXT) USER WIRE-WRAP 60~ 3~ [ill] USER WIRE-WRAP PINS FOR CONNECTING USER lOGIC TO "C" AND "0" DRVll-P MODULE FINGERS +3V WIRE-wRAP PIN FOR PULLING-UP UNUSED GATE INPUTS, ETC. _----1- ~~~~:iD FROM n~-~i--it--t-~ ~f~ \:.@D .. 1 TH ROUGH 120 illIJ •• [lli] •• [ill] -~:~.::. :;~~~:::~~ ~~::.:~.~~~~~~~~: i:i:woo ;;;:;:;;~~~.; BIAKI l - BIAKO l CONTINUITY JUMPER. REMOVE ONLY WH EN USING THE CN2 AND CM2 MODULE FINGERS. iii:=i ;;j:u;~iL:ZiJr; i~wou iii:i BDMGI l - BDMGO l CONTINUITY JUMPER. REMOVE ONt Y WHEN USING THE CR2 AND CS2 MODULE FINGERS. +3V WIRE-WRAP PIN FOR PULLING-UP UNUSED GATE INPUTS, ETC. BDMGI l - BDMGO l CONTINUITY JUMPER. REMOVE ONLY WHEN DMA GRANT ARBITRATION lOGIC IS CONSTRUCTED ON DRVII-P MODULE. SPLIT LUGS TO ACCOMMODATE EXTERNAL CAPACITOR (C3.) WHEN ADJUSTING DELAY BETWEEN BDIN l, BDOUT l, AND BETWEEN VECTOR H INPUTS AND BRPlY l. M7948 Device Address Selection The DRV 11-P will respond to up to four consecutive addresses in the bank 7 area (addresses between 160000 and 177776). The register addresses are sequential by even numbers and are as follows. Register 1 Octal Address BBS7 1xxxxO 1xxxx2 1xxxx4 1xxxx6 2 3 4 DECODED BY BBS7 DECODED FOR I OF 4 REGI STERS SELECTED BY WIRE - WRAP PINS r-------~~-------,,~----------------~----------------__,,~ WIRE- WRAP TO A GROUND WP FOR "ZERO" BITS IN THE ADDRESS DRV 11-P Device Address Select Format Vector Address Selection To cause separate vectors for an interrupt A and an interrupt B, wirewrap WP5 to WP21. 1 ST OCTAL DIGIT LEAST SIGNIFICANT OCTAL PREASSIGNED DIGIT AS (0 OR 4) ZEROS 2 ND OCTAL DIGIT ,.-----A------. ~ oa alT oa AVAILABLE 07 0!5 04 03 I 02 • 01 00 r--- FORA;~Jis~~g - - -...: SEE TEXT. L ___ ~r-~'-~-r~~~-..-~.-~--~--~ WIRE-WRAP TO A GROUND WP FOR "ZERO" -----<. BITS IN THE ADDRESS (SEE TEXT) WP 74 ~fL WP 76 DRV11-P Vector Address Select Format 304 FROM INTERRUPT LOGIC M7948 Bus Reply The BRPl Y l signal is normally issued within 85 ns (max.) of receiving either BOIN l or BOOUT l, depending on the bus cycle. If the user's interface requires more time before ending the bus cycle, the BRPl Y l signal can be delayed up to a maximum of 10 by adding capacitor C39 across the split lugs in the BRPl Y delay circuit. The amount of capacitance required for various delays is given in the following table. C39 R-C Delays for BRPL Y Resistor Capacitance (Constant) (C39 Option) 680Q 680Q 680Q 680Q 680Q 680Q 680 Q o pF 100 pF 120 pF 470 pF 560 pF 680 pF 1200 pF Delay (Typical)" 50 ns 75 ns 80 ns 165 ns 185 ns 210 ns 340 ns *Typical BRPl Y delay with respect to OBOUT and BOIN. Maximum DRV11-P IC Density (All Areas) IC Type Max ICs 6 pin 8 pin 14 pin 16 pin 18 pin 20 pin 22 pin 24 pin 40 pin 122 97 61 52 44 43 6 5 3 305 M7948 User Wirewrap Pins Wirewrap Pin Function WP 1 SPARE 0 - Spare input to the vector address multiplexer. This input can be used to read part of a control/status register. WP2 SPARE 3 - See WP1. WP3 Ground for vector address bit V3. See WP23. WP4 SPARE 1 - See WP1. WP5 V2 - Vector address bit 02. WP6 ENB CLK A H - ENB CLK A H is the clock input to the enable A flip-flop of the A interrupt logic. When ENB CLK A H goes high, ENB DATA A is clocked into the enable A flip-flop. WP7 SPARE 2 - See WP1. WP8 ENB B ST H - ENB B ST H is the status output from the enable B flip-flop of the B interrupt logic. When ENB B ST H is high, the enable B flip-flop is set. WP9 IAKI L - Test point for the BIAK I bus signal. BIAKI L is the processor's response to BIRQ L and is daisy-chained such that the first requesting device blocks the signal propagation. Nonrequesting devices pass the signal on as BIAKO l. The leading edge of BIAKI L causes BIRQ L to be unasserted by the requesting device. WP10 001 L - Test point for data/address bit one. Useful when testing the protocol logic. DO 1 is latched in the protocol logic at the asserted edge of BSYNC l. DO 1 and 002 are decoded to produce the SEL OEV outputs. WP 11 BWTBT L - Test point for the BWTBT bus signal, while BOOUT L is asserted, BWTBT L indicates a byte or word operation: BWTBT L asserted indicates byte operation; BWTBT L unasserted indicates word operation. BWTBT L decoded with BOOUT Land BOAL 0 L forms OUT LB L or OUT HB l. WP 12 R C X X - Test point for monitoring the delay of BRPL Y. 306 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP13 BSYNC H - Test point for the BSYNC l bus signal. BSYNC l indicates that the address is valid. At the assertion of BSYNC l, address information is trapped in four latches. While unasserted, disables all outputs except the vector term of BRPl Y L. BSYNC l is held throughout the entire bus cycle. WP14 000 H - One of 16 data or address lines from the transceivers for user applications. Address bit 00 is used for byte selection: 0 = low byte; 1 = high byte. WP15 BOOUT l - Test point for the BOOUT l bus signal. BOOUT is a strobe signal to effect a data output transaction. BOOUT l is decoded with BWTBT land BOAlO to form OUT lB l and OUT HB L. BOOUT l also causes BRPl Y l to be issued through the delay circuit. WP16 IN WO l - In Word (IN WO) is used to gate input data from a selected register onto the lSI-11 bus. Enabled by BSYNC l and strobed by BOIN L. WP17 DO 1 H - One of 16 data or address lines from the transceivers for user applications. WP18 INIT 0 l - An initialize signal (asserted low) for user applications. WP19 INIT 0 H - An initialize signal (asserted high) for user applications. WP20 BRPl Y l - Test point for the BRPl Y l bus signal. BRPl Y l is generated by VECTOR H (vector term), or by BSYNC and ENB in combination with either BOIN l, or BOOUT L. Capacitor C37 can be added by the user to extend the delay. WP21 VEC RQST B H - Used to distinguish whether device A or device B is making a request. VECT RQST B H is asserted for device B requests and unasserted for device A requests. WP22 V3 - Vector address bit 03. WP23 is used to select the state of vector address bit 03. When not wrapped to a ground pin, vector address bit 03 is a 1. When wrapped to WP3, vector address bit 03 is a O. 307 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP24 ENB DATA A H - Interrupt enable A data line. The level on this line, in conjunction with the ENB ClK A H (see WP6) line, determines the state of the A interrupt enable flip-flop within the interrupt logic. WP25 BIAKO l - Test point for the BIAKO l bus signal. BIAKO l is the daisy-chained signal that is passed by all devices not requesting interrupt service (see WP9). WP26 ENB ClK B H - ENB ClK B H is the clock input to the enable B flip-flop of the B interrupt logic. When ENB ClK B H goes high. ENB DATA B is clocked into the enable B flip-flop. WP27 ENB DATA B H - Interrupt enable B data line. The level on this line, in conjunction with the ENB ClK B H (see WP 26) lines, determines the state of the B interrupt enable flip-flop within the interrupt logic. WP28 ROST B H - When RQST B H is asserted, the bus request flipflop for device B in the interrupt logic is enabled, and BIRO l becomes asserted if the interrupt enable flip-flop is set. WP29 VECTOR H - Test point for VECTOR H. This signal causes BRPl Y l (vector term) to be generated through a delay independently of BSYNC land ENB H. VECTOR H also gates the vector address onto the lSI-11 bus via the vector address generator. WP30 002 l - Test point for data/address bit 2. Useful when testing the protocol logic. 002 is latched at the asserted edge of BSYNC L. 002 and DO 1 are decoded to produce the SEl DEV outputs. WP31 ENB H - Test point for ENB H. This signal is the result of a comparison between the device address on the lSI-11 bus and the device address established by the user. When the addresses compare, ENB H is asserted and sent to the protocol logic. 308 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP32 SEL DEV 6 L - One of four select signals that is true as a function of BDAL 1 Land BDAL2 L if ENB H (see WP31) is asserted at the asserted edge of the BSYNC L. The four select signals indicate that a user's register has been selected for a data transaction. The select signals remain asserted until BSYNC L becomes unasserted. WP33 SEL DEV 4L - See WP32. WP34 SEL DEV 2L - See WP32. WP35 SEL DEV OL - See WP32. WP36 OUT LB L - Out Low Byte is used to load (write) data into the low byte of a selected user register. See WP37. WP37 OUT HB L - Out High Byte is used to load (write) data into the high byte of a selected user register. If used with OUT LB L, the higher, lower, or both bytes can be written. OUT HB L is enabled by BSYNC L and the decode of BWTBT Land BDALO L, and strobed by BDOUT L. WP38 BIRO L - Test point for the BIRO L bus signal. This signal is asserted by a device needing interrupt service. WP39 BDMGO L - This signal is generated by DMA devices as a result of arbitrating the BDMGI L line. Jumper W2 must be removed if the DRV 11-P is to be used for DMA service. WP40 BDMGI H - Used as a source for the BDMGI signal to drive the user's DMA request arbitration logic. See WP39. WP41 ENB A ST H - ENB A ST H is the status output from the enable A flip-flop of the A interrupt logic. When ENB A ST HA is high, the enable A flip-flop is set. WP42 A 12 - Used to select the user's device address along with WP45, 44, 43, 47, 48, 46, 51, 49, 50. When not wrapped to a ground pin, the particular device address bit will be a 1. When wrapped to a ground pin (WP62 for bit A 12), the particular bit will be a O. 309 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP43 A09 - User's device address bit 09. The associated ground pin is WP63. See WP42. WP44 A 10 - User's device address bit 06. The associated ground pin is WP64. See WP42. WP4S A 11 - User's device address bit 06. The associated ground pin is WP6S. See WP42. WP46 A06 - User's device address bit 06. The associated ground pin is WP66. See WP42. WP47 A08 - User's device address bit 06. The associated ground pin is WP67. See WP42. WP48 A07 - User's device address bit 06. The associated ground pin is WP68. See WP42. WP49 A04 - User's device address bit 04. The associated ground pin is WP69. See WP42. WPSO A03 - User's device address bit 06. The associated ground pin is WP70S. See WP42. WPS1 AOS - User's device address bit OS. The associated ground pin is WP 17. See WP42. WPS2 SPARE 4 - See WP 1. WPS3 V4 - Vector address bit 03. The associated ground pin is WP73. See WP 23. WPSS VS - Vector address bit OS. The associated ground pin is WP7S. See WP23. WPS6 V6 - Vector address bit 06. The associated ground pin is WP76. See WP23. WPS7 IN03 H - One of 16 data or address lines to the transceivers for user applications. 310 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP58 SPARE ENB 0 - SPARE ENB 0 and SPARE ENB 1 (WP59) both must be driven low to write data from SPARE inputs 0 through 7 to the LSI-11 bus via the transceiver. For 8-bit input applications, SPARE ENB 0 could be driven by one of the SEL OEV lines, while SPARE ENB 1 could be driven by IN WO L. WP59 SPARE ENB 1 - See WP58. WP60 INOO H - See WP57. WP61 009 H - See WP17. WP62 Ground for user's device address bit A 12. See WP42. WP63 Ground for user's device address bit A09. See WP42. WP64 Ground for user's device address bit A 10. See WP42. WP65 Ground for user's device address bit A 11. See WP42. WP66 Ground for user's device address bit A06. See WP42. WP67 Ground for user's device address bit A08. See WP42. WP68 Ground for user's device address bit A07. See WP42. WP69 Ground for user's device address bit A04. See WP42. WP70 Ground for user's device address bit A03. See WP42. WP71 Ground for user's device address bit A05. See WP42. WP72 004 H - See WP17. WP73 Ground for vector address bit V4. See WP23. WP74 Ground for vector address bit V5. See WP23. WP75 Ground for vector address bit V6. See WP23. WP76 Ground for vector address bit V7. See WP23. 311 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP77 BBS7 H - Test pOint for the bank 7 select (BBS?) bus signal. This line is asserted by the bus master when an address in the upper 4K bank (28K-32K range) is placed on the LSI-11 bus. WP78 SPARE 6 - See WP1. WP79 002 H - See WP17. WP80 IN 02 H - See WP57. WP81 015 H - See WP17. WP82 IN 13 H - See WP57. WP83 014 H - See WP17. WP84 013 H - See WP17. WP85 012 H - See WP17. WP86 IN 12 H - See WP57. WP87 003 H - See WP17. WP90 SPARE 7 - See WP1. WP91 010 H - See WP17. WP92 IN 09 H - See WP57. WP93 Not used. WP94 TRANS ENB C L - Enables user's data to be placed onto the LSI-11 bus. Both TRANS ENB C and A (WP94 and WP 120) and TRANS ENB 0 and B (WP95 and WP 100) must be driven low prior to the processor's read data time. WP95 TRANS ENB 0 L - See WP94. WP96 IN 01 H - See WP57. 312 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP97 VEe ENS H - Test point for VEe ENS H. This signal gates the vector address to the LSI-11 bus, provided that jumper W4 has not been removed. WP97 can be used as the source for VEe ENS H when adding an additional gate to the DRV 11-P for vector address expansion up to 774. WP98 IN 06 H - See WP57. WP99 IN 04 H - See WP57. WP 100 TRANS ENS S L - See WP94. WP101 IN 15 H - See WP57. WP102 IN 14 H - See WP57. WP103 Used to pull up the VEe ENS H line when jumper W4 is removed. WP 104 Not used. WP105 Not used. WP106 008 H - See WP17. WP107 006 H - See WP17. WP108 IN 11 H - See WP17. WP109 011 H - See WP57. WP 110 Not used. WP 111 Not used. WP112 SPARE 5 - See WP1. WP113 IN 08 H - See WP57. WP 114 Not used. 313 M7948 User Wirewrap Pins (Cont) Wirewrap Pin Function WP115 BSYNC H - Test point for BSYNC H. At the asserted edge of this signal, address information is trapped in four latches. BSYNC H is the inversion of BSYNC l. See WP 13. WP 116 Not used. WP117 D05 H - See WP17. WP118 IN 07 H - See WP57. WP119 IN 05 H - See WP57. WP 120 TRANS ENB A L - See WP94. +3 V There are two + 3 V source wirewrap pins on the DRV 11-P. Each + 3 V source can drive up to 13 TTL unit loads. These sources can be used for pulling up unused TTL inputs. 314 M7949 M7949 LAV11 PRINTER INTERFACE Amps +5 0.5 Bus Loads + 12 0 AC 1.8 DC 1.0 Cables BC11S (for LA 180) 7009087 (for Centronics line printer™ models 101, 101A, 1010, 102A, and 303) Standard Addresses LACS LADB 177514 177516 Vectors 200 Diagnostic Program Refer to Appendix A. Related Documentation LAV11 User's Manual (EK-LAV11-0P-001) Field Maintenance Print Set (MP00306) LA 180 DECprinter I Maintenance Manual (EK-LA 180-MM) Microcomputer Interfaces Handbook (EB-20 175-20) 315 M7949 CAUTIONS 1. Switching - Switching the LA 180 off-line while the operating system is running a program may result in the computer hanging and crashing the program. If this occurs, type P to continue. This problem does not occur if the LPV 11 is used in place of the LA V 11. 2. LA 180 to LAV 11 Cable - The only acceptable cable for use between the LA 180 and the LA V 11 is the BC 11 S. The end labeled P2 must attach to the LA 180. The end labeled P 1 must be attached to the LAV11. 3. LA180 Modifications - On the LA180 logic board (54-11023), jumper W6 must be inserted. This ensures + 5 Vdc sense will read the LAV11. Failure to do so will result in a continued error condition in the LAV11 LACS buffer. W6 is located between J2 and J3 on the 54-11023 module. 4. Miscellaneous Jumpers - For an LA 180, the following jumper configuration must be maintained. Jumper Condition Function if Inserted W1 Transmit parity on line +5 Vdc sense from LA 180 +5 Vdc sense from LAV11 DEMAND is asserted low DEMAND is asserted high P STROBE is asserted low P STROBE is asserted high W2 W3 W4 W5 W6 W7 5. I I R R I R I The field replacement for the LAV11 (M7949) is the LPV11 (M8027). 316 M7949 ST ANDARD CONFIGURATION F ADDRESS 1 SW3 J1 SW2 W2 j:3 WI' 1 2 3 4 4 5 VECTOR SWI 4 6 7 8 OFF OFF OFF OFF OFF OFF ON ON OFF ON ON ON ON ON ON OFF ON N.A. STANDARD ADDRESS = 17751 X VECTOR = 200 JUMPER LA180 CENTRONICS WI W2 W3 W4 W5 W6 W7 I I R R I R R I R I KEY: I = INSERT R. REMOVE 11- 4146 317 M7949 All 153-41 A12 (53-51 A9 (S3-21 Al0 (S3-31 A7 IS2-51 AS (53-11 A5 152-31 A3 IS2-11 A6 (52-41 A4 (52-21 V6 (Sl-51 V4 151-31 V7 ISl-61 V5 151-41 V2 (Sl-ll V3 ISl-21 VECTOR SWITCHES LOGIC 0 = SWITCH ON LOGIC 1 - SWITCH OFF MR 0815 02 01 00 LAV 11 Control/Status Register (LACS) LACS Bit Definitions Bit Function 15 Error - The error bit is asserted (1) when an error condition (i.e., torn or no paper) exists in the line printer. This is a read-only bit, which is reset only by manual correction of the error condition. 14-08 Unused. 07 Done - The done bit is asserted (1) when the printer is ready to accept another character. This is a read-only bit set by INIT. The done bit is cleared by loading the LADB register. An interrupt sequence is started if IE (interrupt enable, bit 06) is also set. 318 M7949 LACS Bit Definitions (Cont) Bit Function 06 IE - The interrupt enable bit is set or cleared (read or write bit) under program control. It is cleared by the INIT (initialize) signal on the LSI-11 bus. (lNIT is caused by programmed RESET instruction, console start function, or a power-up or power-down condition.) When IE is set, an interrupt sequence is started if either error or done is also set. 05-02 Unused. 01 On Line - The on line bit is asserted (1) when the LA 180 printer (only) is on-line. Read only. 00 Busy - The busy bit is asserted (1) when the LA 180 printer (only) is performing a print or paper advance operation. PRINTER DATA 15 08 07 06 05 04 03 02 01 00 NOT USED DATA BITS 06-00 LA V 11 Data Buffer Register (LADB) LADB Bit Definitions Bit Function 15-08 Unused. 07 Parity - The parity bit is loaded with the data word if the parity jumper is installed. Write only. 06-00 Data - The data comprises seven bits, with bit 06 being the most significant. This buffered 7-bit character will be transferred to the printer. These are all write-only bits. 319 M7950 M7950 DRV11-B GENERAL PURPOSE DMA INTERFACE Bus Loads Amps +5 1.9 + 12 o AC 3.3 DC 1.0 Cables Two BC04Z Two BC08R Standard Addresses MINC/ DECLAB Word Count Register (WCR) Bus Address Register (BAR) CSR DBR 772410 772412 772414 772416 171770 171772 171774 171776 Vector 124 370 Diagnostic Programs Refer to Appendix A. Related Documentation DRV11-8 General Purpose DMA Interface User's Manual (EK -DRV 1B-OP-OO 1) Field Maintenance Print Set (MPOO 160) Microcomputer Interfaces Handbook (EB-20 175-20) 320 M7950 J1 DEVICE ADDRESS SELECTION SWITCHES VECTOR ADDRESS SELECTION SWITCHES J2 -0 11 - 41~6 DECODED BY BBS? DECODED FOR 1 OF 4 REGISTERS SELECTED BY SWITCHES r---------A---------,~------------------~------------------~,~ OFF' "ZERO" ON- "ONE" DRV 11-8 Device Address Select Format 4 TH OCTAL DIGIT 10 OR 4) 1 ST OCTAL DIGIT 2 NO OCTAL DIGIT 3 RD OCTAL DIGIT I ,------A---.,~ I PREASSIGNED AS ZEROS ,---A--., 00 VECTOR ADDRESS SELECTION SWITCHES OFF' "ZERO" ON' "ONE" DRV 11-8 Interrupt Vector Address Select Format 321 M7950 NEX MAl NT STAT B CYCLE IE XAD 16 FNCT 2 GO LEGEND R = Read only R/W = Read / Wrlle R/WO· Read / Write '0 0 W = Write only Always reads as a 0 CSR Format (11-4186) CSR Bit Functions Bit Function 00 Go - Write only. Always reads as o. 01,02,03 1. Causes ready to be sent to the user's device, indicating that a command has been issued. 2. Allows DMA operation. FNCT 1, 2, 3 - Read/write. 1. 2. Three output. Cleared by INIT. 04, 05 XAD 16,17 - Read/Write. Two bits used for extended addressing. Bits 04 and 05 increment with the address count with the BAR wraps around to O. 06 IE - Read/write. 1. 2. Enables interrupts to occur when ready set. Cleared by INIT. 07 Ready - Read only. Indicates that the DRV 11-B is able to accept a new command. Set by INIT. WCOFLO, ERROR; cleared by go (bit 00). 08 Cycle - Read/write. Cycle eis used to prime a DMA bus cycle; set by CYCLE REQUEST, cleared during DMA cycle, INIT. 09, 10, 11 STAT A, B, C - Read only. Three device status input bits that indicate the state of the DSTAT A, B, and C user signals. 322 M7950 CSR Bit Functions (Cont) Bit Function 12 MAl NT - Read/write. Maintenance bit for use with the MAINDEC diagnostic. 13 ATTN - Read only. Indicates the state of the ATTN user user signal; sets ready, error. 14 NEX - Read/write to 0 bit. 15 1. Nonexistent memory; indicates that as bus master, the DRV 11-B did not receive BRPL Y or that a DA TID cycle was not completed. 2. Set error. 3. Cleared by INIT or by writing it to a O. Error - Read only. 1. Indicates one of the following special conditions. • • NEX (bit 14) ATTN (bit 130) 2. Sets ready (bit 7) and causes an interrupt if IE (bit 6) is set. 3. Cleared by removing the special condition as follows. a. b. NEX is cleared by writing bit 14 to a O. ATTN is cleared by the user device. 323 M7951 M7951 DUV11-DA SYNCHRONOUS SERIAL LINE INTERFACE Amps +5 0.86 Bus Loads + 12 0.32 AC 1.0 Cables DC 1.0 BC05C Standard Addresses Floating - Configurable in the range of 760000-777776. Refer to Appendix B. Vector Floating - Configurable in the range of 300-770. Refer to Appendix B. Diagnostic Programs Refer to Appendix A. Related Documentation DUV 11 Line Interface Technical Manual (EK-DUV 11-TM-OO 1) Field Maintenance Print Set (MP00297) Microcomputer Interfaces Handbook (EB-20 175-20) 324 M7951 TRANSMITTER CHIP RECEIVER CHIP ADDRESS/VECTOR ROCKER SWITCHES 325 M7951 Switch Assignment for Option Switch Pack E55 Switch Number Function SW1 Optional clear - Switch ON enables CLR OPT, which is used to clear RXCSR bits 03, 02, and 01. SW2 Secondary transmit - Switch ON enables secondary data channel between the modem and DUV 11. SW3 Secondary receive - Switch ON enables secondary data channel between the modem and DUV 11. SW4 Sync characters - Switch ON enables the receiver to synchronize internally upon receiving one sync character. The normal condition of receiving two sync characters exists when SW4 is off. SW5 Special feature - Switch ON allows external clock to be internally generated, used when a modem is not being utilized. SW6 Special feature - Optional feature is switched ON for program control of data rate selector. SW7 Maintenance clock - Switch ON enables the clock that is used for maintenance purposes only. SW8 Not used. OFF OFF OFF OFF OFF OFF OFF OFF OFF ON llllllllll SWITCH NO. \ 1 8 I ~ 5 E38 SWITCH LOGICAL 1 = ON LOGICAL 0 = OFF FACTORY ADORESS 1600 E39 SWITCH Device Address Selection 326 o RXCSR 1 TXCSR TXDBUF M7951 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 10101010101010111 0 10111 0 1 0 l x l o l o l ~ ~ ~ ~ ~ ~ L~ ~~~~ ON OFF OFF ON OFF OFF LOGICAL 1 = ON LOGICAL 0 = OFF ~ ~ ~ ~ ~ ~ SWITCH NO. FACTORY ADDRESS 440 3 4 ' 5 7 6 E39 SWITCH 8 I Interrupt Vector Selection Guide for Setting Switches to Select Device Address Module Switch No. Bit No. 1 2 12 11 E38 5 4 10 9 8 3 6 7 8 7 6 5 E39 2 1 4 3 Device Address ON 760010 ON 760020 ON ON 760030 ON 760040 ON ON 760050 ON ON 760060 ON ON ON 760070 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 760100 760200 760300 760400 760500 760600 760700 761000 762000 763000 764000 NOTE ON means switch closed to respond to logical 1 on the bus. 327 M7951 Guide for Setting Switches to Select Vector Address Switch No. Bit No. 3 8 E39 5 4 7 6 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 6 5 8 7 4 Vector Address 3 ON ON ON ON ON ON ON ON ON ON ON ON ON ON 15 14 13 12 ON ON ON ON ON 11 to 300 310 320 330 340 350 360 370 400 500 600 700 ON 09 08 07 06 05 04 03 02 Ot 00 Receiver Status Register (RXCSR) Receiver Status Register Bit Description Bit Function 15 Data Set Change (OAT SET CH) - When set, this bit indicates a modem status change. This bit is set by a transition of any of the following lines: • • • • • Ring Clear to send Carrier Secondary received data Data set ready. If bit 05 of this register is set, the setting of this bit will cause a RCVR interrupt. Read only; cleared by INIT, master reset, and the DTI SEL 0 (RXCSR read strobe). 328 M7951 Receiver Status Register Bit Description (Cont) Bit Function 14 Ring - This bit reflects the state of the modem ring line. When set, this bit indicates that a ring signal is being received from the modem. Read only. 13 Clear to Send (CLR TO SEND) - This bit reflects the state of the clear to send line from the modem. When set, this bit indicates that the modem is ready to accept data. 12 Carrier - This bit reflects the state of the modem carrier. When set, this bit indicates that the carrier is up. Read only. 11 Receiver Active (REC ACT) - When the internal synchronous mode is selected, this bit is set when the proper number of contiguous sync characters (either one or, normally, two) have been received. If external synchronous or isochronous mode is selected, this bit follows the state of the search sync bit (bit 04 of this register). Read only; cleared by INIT, master reset, and SCH SYNC (1) H (search sync) making 1 to 0 transition. 10 Secondary Receive Data (SEC RCV DAT) - This bit reflects the state of the secondary receive data line from the modem. This bit provides a receive channel for supervisory data from the modem to the processor. Read only. 09 Data Set Ready (DAT SET RDY) - This bit reflects the state of the data line from the modem. When set, this bit indicates that the modem is powered up and ready. Read only. 08 STRIP SYNC - This bit determines whether sync characters received from the modem are to be presented to the program for reading. When this bit is set, received characters that match the contents of the sync register do not cause a RCVR interrupt provided no errors are detected, i.e., bit 15 of the RXDBUF is clear. 07 Receiver Done (RX DONE) - This bit is set when synchronization has been achieved and a character has been loaded into the RXDBUF, provided the STRIP SYNC bit is not set. If the STRIP SYNC bit is set and the received character is a sync character without errors, i.e., bit 15 of the RSDBUF is clear, this bit will not be set. 329 M7951 Receiver Status Register Bit Description (Cont) Bit Function 06 Receiver Interrupt Enable (RX INTEB) - When set, allows a RCVR interrupt request to be generated when the RX done bit is set. Read/write; cleared by INIT and master reset. 05 Data Set Interrupt Enable (OAT SET INTEB) - When set, allows a RCVR interrupt request to be generated when the OAT SET CH bit is set. 04 Search Sync (SCH SYNC) - When set in the internal synchronous mode, enables the RCVR synchronization logic and causes the RCVR to start comparing incoming data bits to the contents of the sync register in an attempt to recognize a sync character. Read/write; cleared by INIT and master reset. 03 Secondary Transmit Data (SEC XMIT) - This bit reflects the state of the secondary transmit data line to the modem. This bit provides a transmit channel for supervisory data from the processor to the modem. 02 Request to Send (REO TO SO) - When set, this bit causes the request to send line to the modem to be reasserted. The request to send line is a control lead to the modem. This line must be asserted before the interface can transmit data to the modem. 01 Data Terminal Ready (DATA TERM ROY) - When set, this bit indicates that the interface is powered up, programmed, and ready to receive data from the modem. Setting this bit causes the data terminal ready line to the modem to be asserted. The data terminal ready line is a control lead for the modem communication channel. When asserted, it permits the interface to be connected to the channel. Read/write; optionally cleared by INIT and master reset. 330 M7951 11 • 08 .. 07 • NOT USED f----------- ·00 RCVR DATA READ ONLY ---------------1·1 Receiver Data Buffer (RXDBUF) Receiver Data Buffer Bit Description Bit Function 15 Receiver Error (RX ERR) - This bit is set whenever one of the three receiver error bits is set (logical OR of bits 14, 13, and 12). Read only; cleared only when bits 14, 13, and 12 are cleared. 14 Overrun Error (OVRN ERR) - When set, this bit indicates that the processor has failed to service the RX DONE flag within the time required to load another character into the RXDBUF, i.e., (1 /baud rate) X (bit/char) seconds. Hence, the previous character was overwritten (lost). This condition indicates the loss of at least one character. Read only; cleared by INIT, master reset, and DTI SEL 2 (RXDBUF read strobe). 13 Framing Error (FRM ERR) - When set, indicates that character received was not followed by a valid stop bit. This error only occurs in the isochronous mode of operation. Read only; cleared by INIT, master reset, and DTI SEL 2. 12 Parity Error (PAR ERR) - When set, indicates that the parity of the received character does not agree with the parity programmed (odd or even). If parity is not programmed, this bit is always cleared. 07-00 Receiver Data (RCVR DATA) - This register holds the received character for transfer to the program. The buffer is right justified for 5, 6, 7, or a bits. If parity is received it is also loaded into the buffer at the next vacant higher order bit position. Therefore, if a 5-bit character plus parity is framed by the RCVR, the parity bit would be loaded into bit position 05 in the RXDBUF and presented to the program for reading. If an a-bit character plus parity is framed, the parity bit would not be presented to the program for reading. Read only buffer; cannot be cleared; INIT or master reset sets the buffer to all 1s. Reading the RDXBUF causes the RXDONE bit in the RXCSR to clear. 331 M7951 15 14 13 12 II 10 09 08 07 4 .00 SYNC REGISTER 141.-----------WRITE ONLY----------_.! Parameter Status Register (PARCSR) Parameter Status Register Bit Description Bit Function 13,12 Mode Select (MODE SEL) - These bits control the mode of operation. Modes are selected as follows. Mode Bit 13 Internal Synchronous External Synchronous Isochronous Illegal (Not Used) 1 0 0 Bit 12 1 0 0 Write only. 11, 10 Word Length Select (WORD LEN SEL) - These bits control the length of characters received and transmitted by interface. Word length (not including parity) is selected as follows. Bit/Char Bit 11 Bit 10 5 6 7 8 0 0 1 0 1 0 Write only. 09 PAR ENB - If this bit is set, parity for each character will be (parity enable) generated by the XMTR and checked by the RCVR. If character length is fewer than eight bits, the parity bit for received data is loaded into the RXDBUF for reading by the program. If bad parity is detected at the RCVR, the parity error flag is set (bit 12 of the RXDBUF). Write only. 332 M7951 Parameter Status Register Bit Description (Cont) Bit Function 08 Parity Sense Select (PAR SEN SEL) - When the parity enable bit (bit 09 of this register) is set, the sense of the parity (odd or even) is controlled by this bit. When this bit is set, even parity is generated by the XMTR and checked for by the RCVR (the program does not have to provide a parity bit to the XMTR). When this bit is cleared, odd parity is generated and checked. Write only. 07-00 Sync Register - This register contains the sync character. The sync character is used by the RCVR to detect received sync characters and thereby achieve synchronization. The sync character is used as a fill character by the XMTR when operating in the synchronous mode. Fill characters are operating in the synchronous mode. Fill characters are transmitted when the program fails to provide characters to the XMTR fast enough to maintain continuous transmission, i.e., (1 /baud rate) X (bit/char) seconds - 1/2 (bit time). 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 Transmitter Status Register (TXCSR) Transmitter Status Register Bit Description Bit Function 15 Data Not Available (DNA) - This bit is set by the XMTR when a fill character is transmitted. This applies only to the synchronous mode of operation and is caused by late program response to a TX DONE interrupt request. The processor response to TX DONE must be within (16fbaud rate) - (bit/char) seconds - 1/2 (bit time). If not, the fill character is transmitted. If bit 05 of this register is set, setting this bit causes an XMTR interrupt request. Read only; cleared by INIT, master reset, and DTI SEL 4 (TXCSR read strobe). 333 M7951 Transmitter Status Register Bit Description (Cont) Bit Function 14 Maintenance Data (MAl NT DATA) - This bit is used in the internal loop and external loop maintenance. Read/write bit; cleared by INIT or master reset. 13 Single Step Maintenance Clock (SS ClK) - This bit is used in the internal loop and external loop maintenance modes by diagnostic program to simulate the XMTR and RCVR clocks. Read/write; cleared by INIT or master reset. 12, 11 Maintenance Mode Select 01 and 00 (MSO 1-MSOO) - These bits are used to select the normal mode of operation or one of three maintenance modes. Modes are selected as follows. Mode Bit 12 Bit 11 Normal Internal Maintenance loop External Maintenance loop System Test o o 0 1 o Read/write; cleared by INIT and master reset. 10 Receiver Input (RX INP) - This bit monitors the RCVR input in the internal loop and external loop maintenance modes. Read only. 08 Master Reset (MSTRST) - This bit is used to generate a ClR (clear) pulse, which initializes the registers and the XMTR and RCVR and inhibits the BRPl Y l (bus reply) signal. This bit remains at a 1 for only 3 J-Ls after being set. Read/write. 07 Transmitter Done (TX DONE) - This bit is set by INIT and master reset and when the first bit of the character contained in the XMTR register is placed on the XMTR output line. If bit 06 of this register is set when this bit is set, an XMTR interrupt request is generated. 06 Transmitter Interrupt Enable (TX INTEB) - When set, this bit allows an XMTR interrupt request to be generated by the TX DONE bit. 334 M7951 Transmitter Status Register Bit Description (Cont) Bit Function 05 Data Not Available Interrupt Enable (DNA INTEB) - When set, this bit allows a XMTR interrupt request to be generated by the DNA bit. 04 Send - When set, this bit enables the XMTR and transmission will start when a character is loaded into the TXDBUF. This bit must remain set until the entire message is transmitted. If not, transmission of the character currently in the XMTR register is completed and the XMTR will enter the idle state. Read/write; cleared by INIT and master reset. 03 Half Duplex (HALF DUP) - When this bit is set, operation will be in the half-duplex mode. In this mode, the RCVR is disabled whenever bit 04 of this register is set. 00 Break - When this bit is set, the serial XMTR output D5 SERIAL DATA OUT H is held in the space (constant low) condition; otherwise, operation is normal. This bit is used by the diagnostic program in the internal loop or external loop maintenance modes to inhibit the XMTR output while inputting data to the RCVR via bit 14 of this register. Read/write; cleared by INIT and master reset. 15 • • 08 07. NOT USED • 00 XMTR DATA 1 - - - - - - - - - - WRITE O N L y - - - - - - - - - - - - t · 1 Transmitter Data Buffer (TXDBUF) Transmitter Data Buffer Bit Description Bit Function 07-00 Transmitter Data (XMTR DATA) - This register is loaded by the program with the character to be transmitted. Character length is from five to eight bits. The character is right justified. If a parity bit is enabled, it is generated by the interface. Write only. INIT or master reset places all 1s in this register. 335 M7952 M7952 KWV11-A PROGRAMMABLE REAL TIME CLOCK Amps +5 1.75 Bus Loads + 12 0.01 AC 3.41 Cables DC BC04Z BC08R Standard Addresses CSR BufferIPreset Register (BPR) 170420 170422 Vector 440 Diagnostic Programs Refer to Appendix A. Related Documentation ADV11-A, KWV11-A, AAV11-A, DRV11 User's Manual (EK-ADV 11-0P) Field Maintenance Print Set (MP00200) Microcomputer Interfaces Handbook (EB-20 175-20) 336 o c J1 CLK STl 1 ~R18 ~R19 o 00 BIT 11 BIT 2 ADDRESS SWITCHES BIT 8 BIT 3 o VECTOR SWITCHES MR-OBI7 M7952 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 11 11 11 1 1 1 0 10 1 0 1 1 1 0 1 0 10 1 1 10 1 0 1 0 1 0 I :g~~I~~ STANDARD ADDRESS CONFIGURATION I I I I I I I I I I I I I I I I I I I I OFF OFF OFF ON (170420) I ADDRESS SWITCH (S1) OFF OFF OFF 1 ON OFF OFF 9 10 I MA-0868 KWV 11-A CSR Address Switches (Set for 170420) 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 o 1 0 1 1 0 1 0 1 0 1 0 1 1 10 1 0 11 1 0 1 1 0 1 0 10 I:g~~I~~ STANDARD VECTOR CONFIGURATION (440) VECTOR SWITCH (S3) I I I I I I Ii * * * * * I ON OFF OFF ON OFF OFF 1 7 KWV 11-A Vector Address Switches (Set for 000440) OFF~'ON TTL REFERENCE ------- I ~--------.--_--~--~~I (JI-L1 BOARD HANDLE + ________ ST LEVEL 2. ST SLOPE 1 (J'-Tl RIB BOARD FINGERS S2 KWV 11-A Slope/Reference Level Selector Switches and Controls NOTE The user should take care that both TTL and variable switches for either Schmitt trigger are not on simultaneously. This condition will not damage components, but will produce unpredictable reference levels. Note also that if no Signal is connected to a Schmitt trigger input, both threshold switches for that ST should be open for noise immunity. Alternatively, ST1 IN and ST2 IN can be grounded externally. 338 M7952 INT 2 FOR MAINT ose MAINT ST1 INT OV RATE MODE 1 1 GO 11-4310 CSR Bit Assignments CSR Bit Definitions Bit Function 15 ST2 Flag - Set by the firing of Schmitt trigger 2 or the setting of the MAINT ST2 bit in any mode while the go bit or the ST2 go enable bit is set. Cleared under program control. Also cleared at the 1-going transition of the go bit unless the ST2 go enable bit has previously been set. Must be cleared after servicing an ST2 interrupt to enable further interrupts. When cleared, any pending ST2 interrupt request will be canceled. If enabled interrupts are requested at the same time by bits 07 and 15, bit 07 has the higher priority. Read/write to O. 14 Interrupt on ST2 (lNT 2) - Set and cleared under program control. When set, the assertion of ST2 flag will cause an interrupt. If set while ST2 flag is set, an interrupt is initiated. When cleared, any pending ST2 interrupt request will be canceled. Read/write. 13 ST2 Go Enable - Set and cleared under program control. Also cleared at the 1-going transition of the go bit. When set, the assertion of ST2 flag will set the go bit and clear the ST2 go. enable bit. Read/write. 12 Flag Overrun (FOR) - Set when an overflow occurs and the overflow flag is still set from a previous occurrence, or when ST2 fires and the ST2 flag is already set. Cleared under program control and at the 1-going transition of the go bit. This bit provides the programmer with an indication that the hardware is being asked to operate at a speed higher than is compatible with the software. Read/write. 339 M7952 CSR Bit Definitions (Cont) Bit Function 11 Disable Internal Oscillator (010) - Set and cleared under program control. For maintenance purposes, this bit inhibits the internal crystal oscillator from incrementing the clock counter. Used in conjunction with bit 10 below. Read/write. 10 MAINT OSC - Set under program control. Clearing is not required. Always read as a O. For maintenance purposes, setting this bit high simulates one cycle of the internal 10 MHz crystal oscillator used to increment the clock counter. Write only. 09 MAINT ST2 - Set under program control. Clearing is not required. Always read as a O. Setting this bit simulates the firing of Schmitt trigger 2. All functions initiated by ST2 can be exercised under program control by using this bit. Write only. 08 MAINT ST 1 - Set under program control. Clearing is not required. Always read as a O. Setting this bit simulates the firing of ST 1. All functions initiated by ST 1 can be exercised under program control by using this bit. Write only. 07 OVFLO FLAG - Set each time the counter overflows. Cleared under the program control and at the 1-going transition of the go bit. If bit 6 is set, bit 7 will initiate an interrupt. Bit 7 must be cleared after the interrupt has been serviced to enable further overflow interrupts. If cleared while an overflow interrupt request to the processor is pending, the request is canceled. If enabled interrupts are requested at the same time by bits 07 and 15, bit 07 has the higher priority. Read/write to O. 340 M7952 CSR Bit Definitions (Cont) Bit Function 06 Interrupt on Overflow (INTO V) - Set and cleared under program control. When this bit is set, the assertion of OVFLO flag will generate an interrupt. Interrupt is also generated if bit 6 is set while OVFLO flag is set. If cleared while an overflow interrupt request to the procesor is pending tne request is canceled. Read/write. 05,04, 03 Rate - Set and cleared under program control. These bits select clock counting rate or source. 5 4 3 Rate 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 Stop 1 MHz 100 kHz 10 kHz 1 kHz 100 Hz ST1 Line (50/60 Hz) Read/write to O. 2, 1 Mode - Set and cleared under program control. Mode 0: Mode 1: Mode 2: Mode 3: 2 1 o o o 1 o Read/write. o Go - Set and cleared under program control. Also cleared when the counter overflows in mode o. Setting this bit initiates counter action as determined by the rate and mode bits. In modes 1, 2, and 3 it remains set until cleared. In mode 0 it clears itself when counter overflow occurs. Clearing bit 0 zeros and inhibits the counter. Read/write. 341 M7952 CSR Bit Settings for Mode 0, Single Interval Bit and CSR Name Bit Condition as Written by Processor 15-ST2 FLG 0 Will be set to 1 on ST2 event. Cleared by leading edge of go bit assertion except when ST2 GO ENA has previously been set. 14-INT2 x Set to 1 by program if interrupt on ST2 event is desired. 13-ST2 GO ENA x Set to 1 by program if go is to be set by external signal to ST2. Cleared by leading edge of go bit assertion. 12-FOR (0) 11-D10 0 10-MAINT OSC 0 9-MAINT ST2 0 8-MAINT ST1 0 7-0VFLO FLG (0) Will be set to 1 by counter overflow. Always cleared by leading edge of go bit assertion. 6-INT OV x Set to 1 by program for interrupt on counter overflow. 5-Rate 2 x 4-Rate 1 x Remarks See bit definitions. 3-Rate 0 x 2-Mode 1 0 Set by program to O. 1-Mode 0 0 Set by program to O. O-Go x Set by program to 1 unless ST2 GO ENA is set; remains 1 until written to o by program. Cleared when counter overflows. x = 0 or 1, depending on user requirements. (0) = automatically cleared by go bit assertion. 342 M7952 CSR Bit Settings for Mode 1, Repeated Interval Bit and CSR Name Bit Condition as Written by Processor 15-ST2 FLG 0 Will be set to 1 on ST2 event. Cleared by leading edge of go bit assertion except when ST2 GO ENA has previously been set. 14-INT 2 x Set to 1 by program if interrupt on ST2 event is desired. 13-ST2 GO ENA x Set to 1 by program if go is to be set by external signal to ST2. Cleared by leading edge of go bit assertion. 12-FOR (0) 11-010 0 10-MAINT OSC 0 9-MAINT ST2 0 8-MAINT ST1 0 7-0VFLO FLG (0) Will be set to 1 by counter overflow. Always cleared by leading edge of go bit assertion. 6-INT OV x Set to 1 by program for interrupt on counter overflow. 5-Rate 2 x 4-Rate 1 x 3-Rate 0 x 2-Mode 1 o Set by program to 1. x Same as for mode 0, except that bit is not cleared when counter overflows. Remarks See bit definitions. 1-Mode 0 O-Go x = 0 or 1, depending on user requirements. (0) = automatically cleared by go bit assertion. 343 M7952 CSR Bit Settings for Mode 2, External Event Timing Bit and CSR Name Bit Condition as Written by Processor 15-ST2 FLG o Will be set to 1 on ST2 event. Cleared by leading edge of go bit assertion except when ST2 GO ENA has previously been set. 14-INT2 x Set to 1 by program if interrupt on ST2 event is desired. 13-ST2 GO ENA x Set to 1 by program if go is to be set by external signal to ST2. Cleared by leading edge of go bit assertion. 12-FOR (0) 11-D10 0 10-MAINT OSC 0 9-MAINT ST2 0 8-MAINT ST1 0 7-0VFLO FLG (0) Will be set to 1 by counter overflow. Always cleared by leading edge of go bit assertion. 6-INT OV x Set to 1 by program for interrupt on counter overflow. Remarks x = 0 or 1, depending on user requirements. CO) = automatically cleared by go bit assertion. 344 M7952 CSR Bit Settings for Mode 2, External Event Timing (Cont) Bit and CSR Name Bit Condition as Written by Processor 5-Rate 2 x 4-Rate 1 x 3-Rate 0 x 1-Mode 0 o Remarks See bit definitions. Set by program to 2. O-Go Set by program to 1 unless ST2 GO ENA is set; remains 1 until written to o by program. Cleared when counter overflows. x = 0 or 1, depending on user requirements. (0) = automatically cleared by go bit assertion. Mode 3 (external event timing from 0 base) is identical to mode 2 except that the counter is zeroed after ST2 pulse. Counter continues to increment until go bit is set to O. 345 M7954 M7954 IBV11-A LSI-11/INSTRUMENT BUS INTERFACE Amps Bus Loads +12 AC +5 0.8 o 1.77 (1.5 max.) Cables DC 1.0 BN 11 A used from IBV 11-A to first instrument. BNO 1A used to any additional instruments. Addresses IBS (Instrument Bus Status Register) IBD (instrument Bus Data Register) Standard MINC 160150 160152 171420 171422 Vectors Error Service request Command and talker Listener 420 424 430 434 Diagnostic Program Refer to Appendix A. Related Documentation IBVtt-A LSI-tt/lnstrument Bus Interface User's Manual (EK-IBV11-TM) Digital Interface for Programmable Instrumentation (IEEE Std. 488-1975) Field Maintenance Print Set (MP00274) Microcomputer Interfaces Handbook (EB-20 175-20) 346 M7954 VECTOR ADDRESS SELECT SWITCHES 1511 DEVICE IIBS & IBD REGISTERS) ADDRESS SELECT SWITCHES IS21 IBV 11-A Address Bits 347 M7954 IBS REGISTER ADDRESS FORMAT 15 14 13 12 11 ",,~J~~2~,~~ :'~t.;~1T S2 INDIVIDUAL SWITCH NUMBERS I 10 09 08 07 06 05 04 03 02 01 IIIIIIIII 1 00 O'IBS REGISTER I ' IBD REGISTER NORMALLY 0 (RESERVED FOR FUTURE USE) 10 NOTES: 1. OFF' Logical 0; ON· Logical 1 2. Only tho IBS REGISTER ADDRESS I. configured via S2. The IBD REGISTER ADDRESS always equals tho IBS REGISTER ADDRESS +2. 15 12 13 10 09 08 07 06 05 04 03 02 01 00 INTERRUPT vECTOR o • ERROR I I " 'CONFIGURATION ' ' ' ' ' ,moo (000420) '''"'''.[ OFF OFF OFF I ' SERVICE REQUEST o • COMMAND AND TALKER ON ON ,DISABLE ERRI !~6~~~rTS . . . - ' ' - - _ L - _ . L - _ . L - _ . L -_ _ _ _ _...L-.... 51 INDIVIDUAL SWITCH NUMBERS OFF' NORMAL (ENABLE) '--_ _ _ _ _ _ _ _ _ _ _ _ _ _ _-' ERRI INTERRUPTS NOTES 1 OFF~LoglcoIO. 2 Only the VECTOR ADDRESS bits (8 4) ore conflQured ylO S1. hardware - selected for the functIons shown 3 51-8 OFF: IBV11-A 51 8 ON~Loc;jlcol IS 1 Bits :3 and 2 ore IBV11-A Ihe only system controller connected to the instrument busj ERR1 Inlerruptsenobled ON = Another system controller IS connected to the instrument bus; ERR1 interrupts disabled. IBV 11-A Interrupt Vector Addresses 08 15 IBS REGISTER I I I 1 0 1 0 1 I I 00 07 I I I I I I I I _ BIT I I I Lt:: TCS CR/W) EOPCR/W) REMCR/W) IBC CR/W) LON CR/W) TON (R/W) IE CR/W) ACC (R/W) LNR (R) TKR (R) CMD (R) (NOT USED) (NOT USED) ERI (R) ER2 (R) SRQ (R/W) * MR-0819 Instrument Bus Status Register 348 M7954 IBS Register Bits Description Bit Function 00 Take Control Synchronously (TCS) - Set and cleared under program control to enable or disable the IBV 11-A contro"er-incharge function by taking control synchronously or by negating ATN. Setting TCS wi" cause NRFD to be asserted for at least 500 ns before DAV is checked. ATN is then asserted when DAV is not asserted. NRFD must be unasserted and CMD is set 500 ns (minimum) after ATN is asserted. TCS is cleared by BINIT L and IFC. 01 End or Po" (EOP) - Set and cleared under program control to assert or unassert the EOI line. EOP is cleared by BINIT Land IFC. 02 Remote On (REM) - Set and cleared under program control to assert or unassert the REM line. REM is cleared by BINIT Land IFC. 03 Interface Bus Clear (lBC) - When set, the leading edge of IBC produces IFC for 125 (approximately). At the end of IFC, TCS is automatically asserted and IBC is automatically cleared. IBC is cleared by BINIT L. 04 Listener On (LON) - Set or cleared by the program to enable or disable the IBV 11-A listener function. When LON is set and the DAV line is asserted, the IBS LNR bit (bit 08) becomes set. When LON is cleared, the IBV11-A ignores DAV. LON is cleared by BINIT Land IFC. 05 Talker On (TON) - Set or cleared by the program to enable or disable the IBV 11-A talker function. TON is cleared by BINIT L and IFC. 06 Interrupt Enable (IE) - Set and cleared by the program to enable or disable the IBV 11- A talker function. TON is cleared by BINIT L and IFC. 07 Accept Data (ACC) - Set and cleared by the program. When ACC is cleared, reading a data byte from the DIO lines wi" automatica"y assert the DAC line and clear the LNR bit (bit 08). When ACC is set, the program must clear the low byte of the IBD register in order to clear the LNR status bit and assert the DAC line. 349 M7954 IB5 Register Bits Description (Cont) Bit Function 08 Listener Ready (LNR) - When set, LNR indicates that the IBV 11A has a data or command byte that is ready for reading from the low byte of the IBO. LNR is set when LON is set and the DAV line becomes asserted. LNR is cleared by reading the IBO low byte if ACC is cleared, or by clearing the IBO low byte if ACC is set. LNR is also cleared when LON is cleared by the program and by BINIT Land IFC. 09 Talker Ready (TKR) - When set, TKR indicates to the LSI-11 processor that the IBV 11-A is ready for the next data byte to betransmitted to the 010 lines via the low byte of the IBD register. 10 Command Done (CMD) - When set, CMO indicates to the LSI-11 processor that the IBV 11-A is ready for the next command byte to be transmitted to the 010 lines via the low byte of the IBD register. 11 Not used. Read as O. 12 Not used. Read as O. 13 Error 1 (ER 1) - Set whenever a conflict occurs between the instrument bus ATN, IFC, or REN lines and their IBV 11-A control hardware. When set, ATN H is cleared and cannot be set. This condition can only be cleared by clearing the cause of the error. ER 1 can occur when another system controller is connected to the instrument bus. The error can then be suppressed by setting the ER 1 inhibit switch (S 1-8) on the IBV 11-A module to the ON position. If the IBV 11-A is the only system controller, set S 1-8 to the OFF position. 14 Error 2 (ER2) - Set when the IBV 11-A tries to send a data or command byte while there is no active listener or command acceptor on the instrument bus. ER2 is cleared by clearing both the TON and TCS bits. 15 Service Request (SRO) - This bit always indicates the status of the instrument bus SRO line. It may be written (set and cleared) if the ER 1 inhibit switch is set. 350 M7954 OS 15 IBD REGISTER I I I I I I I I 07 I 00 I I I I I I - BIT I I I' NOTE: I 1 NDAC<S:I> (R/W) (DATA LINES) DAC (R) (NDAC INVERTED) DAV (R) RFD (R) (NRFD INVERTED) SRQ (R) REN (R) IFC (R) ATN (R) EOI (R) R/W = Read I Write Bit R • Read-Only Bit * May be written only if ERI inhibit switch is on. MR-082a Instrument Bus Data Register IBD Register Bit Description Bit Function 15-8 Instrument bus control line status. The program can monitor the signal status of all eight control signals by reading this byte. Note that DAC (bit 08) and RFD (bit 10) are inverted with respect to the actual instrument bus signal lines. 7-0 Instrument bus data input/output. The program can read or write via the register byte to receive or transmit command or data bytes over the instrument bus. Bits 7 -0 correspond to DIO lines 8-1. 351 M7955 M7955 MSV11-C MOS READ/WRITE MEMORY Module Model Description M7955-YA MSV 11-CA 4K by 16-bit read/write memory Amps Bus Loads Cables +5 + 12 1.1 0.54 (2.0 max.) (0.56 max.) AC 2.32 None DC 1 Standard Addresses Module is shipped configured to start at bank o. Vectors None Diagnostic Programs Refer to Appendix A. Related Documentation MSVll-C User's Manual (EK-MSV11-0P) Field Maintenance Print Set (MP00259) Microcomputer Processor Handbook (EB-18451-20) 352 M7955 Sl S2 S3 S4 S5 OFF~ON W14 W15 W12 W4 W6 W2 W1 W5 W3 M7955/MSV 11-C Jumpers NOTES 1. Only one dynamic memory module in a system is needed to reply to the refresh bus transactions initiated by the processor. The module selected should be the one with the longest access time. 2. If a REV11 (M9400-YA or M9400-YC) provides refresh, only the processor-resident memory (if present) should reply to refresh. If the processor board has no resident memory, the memory module electrically farthest from the REV11 should reply. 3. If MSV11-Cs are mixed with MSV11-Bs, the MSV11-Cs should use internal refresh. Again, the memory electrically farthest from the refreshing device should reply. Refer to the "Refresh Configuration Procedure" in the "Systems Configurations" section. 353 M7955 MSV11-C Jumper Configuration When Shipped Jumper Name W1 W2 W3 W5 Jumper State Function Implemented Battery backup power connected to system power. Battery backup power only. W1 W2 W3 W5 R I I R I R R I Battery backup power available but not desired for this MSV 11-C module. W6 W7 Internal refresh enabled. Reply to refresh disabled. W6 W7 R External refresh; no reply. External refresh; reply enabled. W4 W8 W12 W16 W14 R R Factory configured to enable the memory banks appropriate to the memory model. These are normally not changed except for: 1. Maintenance - Refer to chapter 4 of MSV11-C User's Manual, EK -MSV 11-0P. 2. Configuring for 28K system: Remove W16 to disable upper 4K. See configuration rules in the "Systems Configurations" section. Bus grant continuity provided. W15 • Memory bank enable jumpers when supplied. 354 M7955 Module Number Option Designation Memory Size W4 W8 W12 W16 M7955-YD M7955-YC M7955-YB M7955-YA MSV11-CD MSV11-CC MSV11-CB MSV11-CA 16K 12K 8K 4K I I I I I I I R I I I R R R R R MsV11-CD Addressing Summary Starting Address MsV11-CD Banks Address Range 0 20000 40000 60000 100000 120000 140000 160000 200000 220000 240000 260000 300000 320000 340000 360000 400000 420000 440000 460000 500000 520000 540000 560000 600000 620000 640000 660000 700000 720000 740000 760000 0-3 1-4 2-5 3-6 4-7 5-10 6-11 7-12 10-13 11-14 12-15 13-16 14-17 15-20 16-21 17-22 20-23 21-24 22-25 23-26 24-27 25-30 26-31 27-32 30-33 31-34 32-35 33-36 34-37 0-77777 20000-117777 40000-137777 60000-157777 100000-177777 120000-217777 140000-237777 160000-257777 200000-277777 220000-317777 240000-337777 260000-357777 300000-377777 320000-417777 340000-437777 360000-457777 400000-477777 420000-517777 440000-537777 460000-557777 500000-577717 520000-617777 540000-637777 560000-657777 600000-677777 620000-717777 640000-737777 660000-757777 700000-777777 x x x x-x x-x X.-x 355 Switch Setting 51 52 53 54 55 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M7955 NOTES 1. Switch setting: 1 = ON 0= OFF 2. Each memory bank = one 4K address space. 3. Switches 6, 7, and 8 are not used. NOTE When used in PDP-l1/23 systems, the MSV11-C memory cannot be configured in the 56K-64K byte (28K-32K word) range or in the 248K-256K byte (124K-128K word) range. 356 M7957 M7957 DZV11 ASYNCHRONOUS MULTIPLEXER Amps Bus Loads +5 + 12 1.15 0.39 AC 1.26 DC 1.0 Cables BC11-U Standard Addresses Floating - Configurable within the range of 160000-177770. Register Mnemonic Address Control and Status Register Receiver Buffer Line Parameter Register Transmitter Control Register Modem Status Register Transmit Data Register CSR RBUF LPR TCR MSR TOR 16XXXO 16XXX2 16XXX2 16XXX4 16XXX6 16XXX6 xxx = selected in accordance with floating device address convention. Refer to Appendix B. Vectors 300-777 in accordance with floating interrupt vector assignments. Refer to Appendix B. Diagnostic Programs Refer to Appendix A. 357 M7957 Related Documentation DZVll Asynchronous Multiplexer Technical Manual (EK-DZV11-TM) DZV 11 Print Set (MP-00462-00) Microcomputer Interfaces Handbook (EB-20 175-20) NOTES 1. Use H325 test connector to test individual lines. 2. Use H329 test connector to test module without cables. x x 15 ADDRESS SELECTION I I 1 X \~, r-A----.. 14 13 12 11 10 09 08 X 1 07 06 05 X X X 04 SWITCH E30 03 02 01 00 10 Address Switches r-"---.,...---'---., ~ ,,---"---., ~ .,---"'----, 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 VECTOR ADDRESS SWITCH E2 Vector Switches Modem Control Jumpers There are eight jumpers used for modem control. The jumpers labeled W 1 through W4 connect Data Terminal Ready (DTR) to Request To Send (RTS). This allows the DZV 11 to assert both DTR and RTS if using a modem that requires control of RTS. These jumpers must be installed to run the cable and external test diagnostic programs. The remaining four jumpers; W5 through W8, connect the Forced Busy (FB) leads to the RTS leads. With these jumpers installed, the assertion of an RTS lead places an ON or BUSY signal on the corresponding forced busy lead. The forced busy jumpers (W5 through W8) are cut out unless the modem requires them. 358 M7957 W5 WB -----..-C ~1 TE3 a:::: L-...-. L........--.-----,I ~?_---' W7 W6 ~---,I ~~_----' W1~ W4 ,...----W2 W12* W9' = ~W3 j T;1\ W13' W14' W15' W16' A12 VB A3 10000000000/ W10' V3 moooooom ADDRESS SWITCHES VECTOR SWITCHES 'NOTES: JUMPERS W9, W12, W13, W14, W15, AND W16 ARE REMOVED ONLY FOR MANUFACTURING TESTS_ THEY SHOULD NOT BE REMOVED IN THE FIELD_ JUMPERS W10 AND W11 MUST REMAIN INSTALLED WHEN THE MODULE IS USED IN A BACKPLANE THAT SUPPLIES LSI-11 BUS SIGNALS TO THE C AND D CONNECTORS OF THE DZV11 (SUCH AS THE H9270). WHEN THE MODULE IS USED IN A BACKPLANE THAT INTERCONNECTS THE C AND D SECTIONS TO AN ADJACENT MODULE, JUMPERS W10 AND W11 MUST BE REMOVED_ M7957 Jumper Locations Jumper Configuration Jumper Connection Line W1 W2 W3 W4 W5 W6 W7 W8 OTR to RTS OTR to RTS OTR to RTS OTR to RTS RTS to FB RTS to FB RTS to FB RTS to FB 03 02 01 00 03 02 01 00 359 M7957 CONTROL AND STATUS (CSR) CSR Bit Assignments CSR Bit Assignments Bit Function 00-02 Not used. 03 Maintenance - This bit, when set, loops all the transmitter's serial output leads to the corresponding receiver's serial input leads on a TTL basis. While operating in maintenance mode, the EIA received data leads are disabled. Normal operating mode is assumed when this bit is cleared. Read/write. 04 Master Clear - When written to a 1, this bit generates "initialize" within the DZV 11. A read-back of the CSR with this bit set indicates initialize in progress within the device. This bit is self-clearing. All registers, silos, and UARTS are cleared with the following exceptions. 1. Only bit 15 of the receiver buffer register (valid data) is cleared; the remaining bits, 00-14, are not. 2. The high byte of the transmitter control register is not cleared by master clear. 3. The modem status register is not cleared by master clear. 05 Master Scan Enable - This read/write bit must be set to permit the receiver and transmitter control sections to begin scanning. When cleared, transmitter ready (CSR 15) is inhibited from setting and the received character buffers (silos) are cleared. 06 Receiver Interrupt Enable - This bit, when set, permits setting CSR 07 or CSR 13 to generate a receiver interrupt request. Read/write. 360 M7957 CSR Bit Assignments (Cont) Bit Function 07 Receiver Done - This is a read-only bit that sets when a character appears at the output of the first-in/first-out (FIFO) buffer. To operate in interrupt-per-character mode, CSR 06 must be set and CSR 12 must be cleared. With CSR 06 and CSR 12 cleared, character flag mode is indicated. Receiver done clears when the receiver buffer register (RBUF) is read or when master scan enable (CSR 05) is cleared. If the FIFO buffer contains an additional character, the receiver done flag stays cleared a minimum of one microsecond before presenting that character. 08-09 Transmitter Line - These read-only bits indicate the line number whose transmit buffer requires servicing. These bits are valid only when transmitter ready (CSR 15) is set, and are cleared when master scan enable is cleared. Bit 08 is the least significant bit. 10-11 Not used. 12 Silo Enable Alarm - This is a read/write bit. When set, it enables the silo alarm counter to keep count of the number of characters stored in the FIFO buffer. The counter is cleared when the silo alarm enable bit is cleared. Conditioning of this bit must occur prior to any character reception. 13 Silo Alarm - This is a read-only bit set by the hardware after 16 characters have been entered into the FIFO buffer. Silo alarm is held cleared when silo alarm enable (CSR 12) is cleared. This bit is reset by a read to the receiver buffer register and does not set until 16 additional characters are entered into the buffer. If receiver interrupt enable (CSR 06) is set, the occurrence of silo alarm generates a receiver interrupt request. Reception with CSR 06 cleared, permits flag mode operation of the silo alarm bit. 14 Transmitter Interrupt Enable - This bit must be set for transmitter ready to generate an interrupt. Read/write. 361 M7957 CSR Bit Assignments (Cont) Bit Function 15 Transmitter Ready - This bit is read only and is set by the hardware. This bit sets when the transmitter clock stops on a line whose transmit buffer may be loaded with another character and whose associated TCR bit is set. The transmitter number, specified in CSR 08 and CSR 09, is valid only when transmitter ready is set. Transmitter ready is cleared by any of the following conditions: a. when master scan enable is cleared b. when the associated TCR bit is cleared for the line number pointed to in CSR 08 and CSR 09 c. at the conclusion of the load instruction of the transmit data register (low byte only). If additional transmit lines require service, transmitter ready reappears within 1.4 microseconds from the completion of the transmit data register load instruction. The occurrence of transmitter ready with transmitter interrupt enable set, generates a transmitter interrupt request. 362 M7957 RECEIVER BUFFER IRBUF) DATA VALID RX RX LINE B LINE A RBUF Bit Assignments RBUF Bit Assignments Bit Function 00-07 Received Character - These bits contain the received character, right justified. The least significant bit is bit 00. Unused bits are o. The parity bit is not shown. 08-09 Received Character Line Number - These bits contain the line number upon which the received character was received. Bit 08 is the least significant bit. 10-11 Not used. 12 Parity Error - This bit is set if the sense of the parity of the received character does not agree with that designated for that line. 13 Framing Error - This bit is set if the received character did not have a stop bit present at the proper time. This bit is usually interpreted as indicating the reception of a break. 14 Overrun Error - This bit is set if the received character was preceded by a character that was lost due to the inability of the receiver scanner to service the UART receiver holding buffer on that line. 15 Valid Data - This bit, when set, indicates that the data presented in bits 00- 14 is valid. This bit permits the use of a characterhandling program that takes characters from the FIFO buffer until there are no more available. This is done by reading this register and checking bit 15 until the program obtains a word for which bit 15 is o. 363 M7957 LINE PARAMETER (LPR) LPR Bit Assignments LPR Bit Assignments Bit Function 00-01 Parameter Line Number - These bits specify the line number for which the parameter information (bits 3-12) is to apply. Bit 00 is the least significant bit. 02 Not used. Must always be written as a 0 when specifying the parameter line number. Writing this bit as a 1 extends the parameter line number field into nonexistent lines. Parameters for lines 00-03 are not affected. 03-04 Character Length - These bits are set to receive and transmit characters of the length (excluding parity) as shown below. 04 03 0 0 0 1 0 5 bit 6 bit 7 bit 8 bit 05 Stop Code - This bit sets the stop code length (0 = 1 unit stop; 1 = 2 unit stop or 1.5 unit stop if a five-level code is employed). 06 Parity Enable - If this bit is set, characters transmitted on the line have an appropriate parity bit affixed, and characters received on the line have their parity checked. 07 Odd Parity - If this bit is set and bit 06 is set, characters of odd parity are generated on the line and incoming characters are expected to have odd parity. If this bit is not set, but bit 06 is set, characters of even parity are generated on the line, and incoming characters are expected to have even parity. If bit 06 is not set, the setting of this bit is immaterial. 364 M7957 LPR Bit Assignments (Cont) Bit Function 08-11 Speed Code - The state of these bits determines the operating speed for the transmitter and receiver of the selected line. 11 10 09 08 Baud Rate 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 0 0 1 0 1 0 1 50 75 110 134.5 150 300 600 1200 1800 2000 2400 3600 4800 7200 9600 Invalid 12 Receiver Enable - This bit must be set before the UART receiver logic can assemble characters from the serial input line. This bit is cleared following a BINIT or device master clear. 13-15 Not used. 365 M7957 15 12 11 10 09 08 07 04 TRANSMIT CONTROL (TCR) 03 02 01 I 00 I I I LINE LINE LINE LINE ENAB ENAB ENAB ENAB a 3 2 1 TCR Bit Assignments The TCR bits are represented in bits 00-03. These bits are read/write and are cleared by BINIT or device master clear. Bits 04-07 are not used and read as O. The high byte of the TCR register contains the writable modem control lead, the Data Terminal Ready (OTR). Bit designations are as follows. Bit 08 09 10 11 12-15 Name OTR line 00 OTR line 01 OTR line 02 OTR line 03 Unused; read as O. Assertion of a OTR bit puts an ON condition on the appropriate modem circuit for that line. OTR bits are read/write and are cleared only by BINIT. Jumpers have been provided to allow the RTS circuits to be asserted with OTR assertions. 07 12 15 MODEM STATUS (MSR) 04 NOT USED NOT USED MSR Bit Assignments Modem Status Register The Modem Status Register (MSR) is a 16-bit read-only register. A read to this register results in the status of the readable modem control leads, ring and carrier. The ON condition of a modem control lead is interpreted as a logical 1. Bits 04-07 and 12-15 are unused and read as a O. Remaining bit designations are as follows. Bit 00 01 02 03 04-07 Bit Name Ring line 00 Ring line 01 Ring line 02 Ring line 03 Unused; read as O. 08 09 10 11 12-15 366 Name Carrier line 00 Carrier line 01 Carrier line 02 Carrier line 03 Unused; read as O. M7957 15 TRANSMIT DATA 12 NOT USED (TOR) TOR Bit Assignments Transmit Data Register The Transmit Oata Register (TOR) is a byte- and word-addressable, writeonly register. Characters for transmission are loaded into the low byte. TOR bit 00 is the least significant bit. Loading of a character should occur only when transmitter ready (CSR 15) is set. The character that is loaded into this register is directed to the line defined in CSR bits 08 and 09. The high byte of the TOR is designated as the break control register. Each of the four multiplexer lines has a corresponding break bit for that line. TOR bit 08 represents the break bit for line 00, TOR bit 09 for line 01, etc. TOR bits 12 - 15 are unused. Setting a break bit forces that line's output to space. This condition remains until cleared by the program. This register is cleared by BINIT or device master clear. The break control register can be utilized regardless of the state of the device maintenance bit (CSR 03). 367 M8012 M8012 BDV11 BUS TERMINATOR, BOOTSTRAP, AND DIAGNOSTIC ROM Amps +5 1.6 Bus Loads + 12 .07 AC 2 Cables DC None Standard Addresses ROM Window Page Control Reg. Scratch Pad Reg. Option Select Reg. Display Reg. Line Clock CSR 173000-173776 177520 177522 177524 (read only) 177524 (write only) 177546 Standard Vectors Line Clock 100 Diagnostic Programs Refer to Appendix A. Related Documentation BDVII Bus Terminator, Bootstrap, Diagnostic ROM Technical Manual (EK-BDV 11-TM) Field Maintenance Print Set (MP00489) Microcomputer Interfaces Handbook (EB-20175-20) 368 M8012 PURPLE RED GREEN LED BLACK O~FF ~N __ 2 E15 SWITCH "A" DIAGNOSTIC/ BOOTSTRAP SWITCHES __ 3 __ 4 __ 5 __ 6 __ 7 -_B oDpN OFF 23-0046E2 E21 ~N ~ __ 2 SWITCH "B" -4 3 __ __ 5 DIAGNOSTIC/BOOTSTRAP SWITCHES, BEVNT SWITCH A D WITH ECO MB012-1-00D1 WITHOUT ECO L.::..:_ _--'-_ _ _---' BDV 11-A Switches and Indicators D4 D6 D3 D2 D1 S2 ~ooo [§""] GREEN LED RESTART SWITCH S1 rcn) HALT EN~BLE Diagnostic Light Display 777524 READ ONLY 12 15 11 07 OB 00 NOT USED SWITCH NUMBER ON = ONE OFF = ZERO ~ ______v-_ _ _ ~J'~ __- - - -_ _ _ ~ _ _ _ _ _ _ _ _J E21 E15 (SWITCH "8") (SWITCH "A") Switch Register 369 M8012 777524 WRITE ONLY 15 08 07 04 03 02 01 00 D4 D3 D2 D1 NOT USED LED LOAD "0" TO TURN ON LED Display Register 777546 07 15 06 05 00 NOT USED NOT USED 1 = LINE CLOCK ENABLE SWITCH "B5" MUST 8E "ON" FOR PROGRAM CONTROLLED LINE CLOCK Line Clock CSR 777520 08 15 ~ ______________ ~ ________________ -JI'~ 07 00 ________________ ~ ______________ ~ 1ST 128 WORDS 2ND 128 WORDS Page Control Register 777522 00 15 Read/Write Register 370 M8012 BDV11 Hardware Registers Register Function Bus Address Page Control Register (PCR) Controls mapping of ROM pages into physical ROM addresses. Cleared when power is turned on or when RESTART switch is activated. Sixteen bits. 177520. Word or byte byte addressable; can be read or written. Read/Write Register Maintenance register used for diagnostics. Cleared when power is turned on or when RESTART switch is activated. Sixteen bits. 177522. Word or byte byte addressable; can be read or written. Switch Register Used for maintenance and system configuration (selects diagnostic and/ or bootstrap programs for execution). Bits 0-11 of the register (corresponding to E 15-1 through E 15-8 and E21-1 through E21-4, respectively) are associated with BOAL <0: 11 > L, respectively. When an individual switch of the register is closed (on), the corresponding BOAL signal is low (1). Twelve bits. 177524. Read-only register. Display Register Controls the diagnostic light display. Bits 0-3 of the register control LEOs 01-04, respectively. When a bit is set, the corresponding LED is off; cleared (all lights on) when power is turned on or when RESTART switch is activated. Four bits. 177524. Word or byte addressable; writeonly register. 371 M8012 BDV 11 Hardware Registers (Cont) Register Function Bus Address Line Clock CSR When cleared. this register clamps the BEVNT signal low (if BEVNT switch is closed). This action permits program control of the LSI-11 line time clock (LTC) function. Register cleared when power is turned on or when RESTART switch is activated. One bit. 177546. Word or byte addressable; writeonly register. BDV11 (For ROMs 23-045E2 and 23-046E2 only) Switch Settings and Mnemonics For the discussion that follows. the M8012 switch E15 will be called "A" and E21. "B." Switches A 1 through B4 are defined as follows: A10N A2 ON A3 ON Execute CPU tests on power-up or restart. Execute memory test on power-up or restart. DECNET BOOT - A4. A5. A6. A7 are used as arguments. Device A4 AS A6 A7 DUV11 DLV11-E DLV11-F ON OFF OFF OFF ON ON OFF OFF OFF OFF OFF ON DLV11-E RCSR = 175610; DLV11-F RCSR = 176500. 372 M8012 A4 ON Console test and dialog (A3 OFF). A4 OFF Turnkey BOOT dispatched by switch setting (A3 OFF). Switches A5, A6, A7, A8, B1 are used as arguments. Device AS A6 A7 A8 81 Loop on Error RK05 RL01 RX01 RX02 BDV11 ROM OFF OFF OFF OFF OFF ON OFF OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF The BDV 11 ROM BOOT uses the following switches as arguments. (X = don't care.) ROM 82 83 84 Extended DIAG 2708s Program ROM ON OFF OFF X ON OFF X X ON All unused patterns or mnemonics will default to ROM BOOT if switch B2, B3, or B4 is ON. If an unrecognized mnemonic or switch setting (A5 through B 1) is encountered, the presence of additional ROM is checked (by checking B2, 3, 4) and if present, the ROM BOOT is envoked. If an unrecognized switch setting is encountered, a copy of the switches is placed in location 2 with bit 15 set. If no additional ROM exists, the switch checking routine will halt or the mnemonic routine will reprompt. If the console test is selected, the console test prompts with: ZZK Where ZZ is the decimal multiple of 1024. START? Words of RAM found in the system. Allowed responses are a two-character mnemonic with a one-digit octal unit number, or one of two special, single-character mnemonics. The response must be followed by a return. The special single-character mnemonics are: Y N Use switch settings to determine boot device; or, HALT. Enter microcode ODT. 373 M8012 The two-character mnemonics are as follows. "N" is a digit from 1 to 7 indicating the unit number of the device. DKN DLN DXN DYN RK05 bootstrap RLO 1 bootstrap RXO 1 bootstrap RX02 bootstrap BDV11 HALT/ENABLE, RESTART, AND BEVNT SWITCHES HALT /ENABLE Switch When this switch is in the ENABLE position, the LSI-11 CPU can operate under program control. If the switch is placed in the HALT position, the CPU enters the halt mode and responds to console OOT commands. While in the halt mode, the CPU can execute single instructions, facilitating maintenance of the system. Program control is re-established by returning the switch to the ENABLE position and entering a "P" command at the console terminal (providing the contents of register R7 were not changed). Refer to chapter 2 of the Microcomputer Handbook (1977 -1978) for a description of console OOT command usage. RESTART Switch When the RESTART switch is cycled, i.e., moved from one side to the other and back, the CPU automatically carries out a power-up sequence. Thus, the system can be rebooted at any time for maintenance purposes. BEVNT L Switch Contact 5 of dip-socket switch E21 is the BEVNT L switch. When the switch is off (open) the LSI-11 bus BEVNT L signal can be controlled by the powersupply-generated LTC signal. When the switch is on (closed), the LTC function is program controlled; i.e., a single-bit write-only register in the logic (address 177546, bit 6) clamps BEVNT L low when the register is cleared. (The register is automatically cleared when the power is turned on or when the RESTART switch is cycled.) The KW 11-L line time clock option also uses bit 6 as the enable bit. POWER OK LED and Tip Jacks This green LED is lighted when the + 12 Vdc supply voltage is greater than + 10 V and the +5 Vdc supply voltage is greater than +4 V. The + 12 Vdc voltage and the + 5 Vdc voltage can be measured at the tip jacks as indicated below. (Both J2 and J3 have a 560 Q resistor in series to prevent damage from a short circuit; use at lease a 20,000 Q V meter to measure the voltage.) 374 M8012 Jack Color Voltage J1 J2 J3 Black Red Purple Ground +5 Vdc + 12 Vdc Secondarily, the LED indicates the octal point for the diagnostic light display. The BDV11 (M8012) is the new bootstrap module for the PDP-11/03s. It is a quad module and it has 2K words of diagnostics in ROM installed on the board. The failures of these diagnostics are indicated by the HALT address in the ROM and by the state of the error lights on the board. The "Diagnostic LED Error Display" table provides a cross-reference between the indications in the error lights and the failing system function. The "BDV 11 Diagnostic Error Addresses" table provides a cross-reference between the HALT PC and the failing system function. (The HALT PC will be displayed on the console terminal.) 375 Diagnostic LED Error Display 04 06 03 02 01 Red Green Red DCOK Red Red Comments X OFF X X X + 12 Vdc or +5 Vdc is bad. OFF ON OFF OFF ON CPU test error or fault, or configuration error. OFF ON OFF ON OFF Memory test error; register R 1 points to bad location. OFF ON OFF ON ON Console serial line unit does not transmit. OFF ON ON OFF OFF Console terminal test waiting for response from operator on keyboard. OFF ON ' ON OFF ON Load device status error. OFF ON ON ON OFF Secondary bootstrap code incorrect. NOP instruction is not in location 000000; the medium is probably bad. OFF ON ON ON ON DECNET waiting for response from host computer. ON ON OFF OFF OFF DECNET received DONE FLAG set. ON ON OFF OFF ON DECNET message received. ON ON OFF ON OFF ROM BOOTSTRAP error. ON ON ON ON ON HAL T switch is ON, unable to run (check computer and BDV 11 HAL T switch); or power-up mode is wrong; or system is hung. M8012 04 06 03 02 01 Sl S2 02 000 1= 1= / GREEN LEO Diagnostic LED Error Display BDV11 Diagnostic Error Addresses Error Address Cause of Error 173022 Memory error 1. Write address into itself. 173040 Serial line unit switch selection incorrect; error in switches. 173046 Serial line unit error. CSR address for selected device in error. Check CSR for selected device in floating CSR address area. 173050 CPU error 1. Register RO contains address of error. 173052 Memory error 2. Data test failed. 173106 Memory error 3. Write and read bytes failed. 173202 ROM loader error. Checksum on data block. 173240 CPU error 4. RO contains address of error. 173366 ROM loader error. Checksum on address block. 173402 ROM loader error. Jump address is odd. 173532 RL device error. 173634 CPU error 3. RO points to cause of error. 173642 A "NO" typed in console terminal test. 173656 Switch mode HALT. A match was not made with switches. 173656 RK device error 173670 Console terminal test. No DONE flag. 173706 CPU error 2. RO points to cause of error. 173712 RX device error 377 M8012 o ,.....-v- 3: 3:3: 3: J2 Jl mTI o CONMCIlJ3 3:3:3:3:~ W12 ~ Wll OFF ON ~: =W13 W5 ~ ~ W6 OFF ON ~1 @J5 MR·l2QP BDV 11 Switch and Jumper Locations 378 M8012 00000 D1 D2 D3 D6 D4 OFF ON __ 1 __ 2 __ 3 __ 4 W13 __ 5 -c:::::J- __ 6 __ 7 __ B W5 ij W6 ~ E21 (DIAGNOSTIC/BOOTSTRAP SWITCHES, BEVNT SWITCH) E15 (DIAGNOSTI C/ BOOTSTRAP SWITCHES) BDV 11 Switches and Indicators Socket Selection Logic The socket selection logic determines which pair of sockets responds to the ROM address signals. (Although the ROMs in the sockets actually respond, it is said, for ease of explanation, that the sockets respond). Jumpers are inserted selectively in positions W 1-W4 and W9-W 12. These jumpers cause the PCR page numbers and the selection signals (and, therefore the sockets) to be related in definite ways. Group A in the "BDV 11 Selection Signals/Sockets" table indicates that PCR pages are assigned to specific ROM sockets. This is true within the confines of the BDV11 module shipped by DIGITAL. On such a module, jumpers W1-W4 and W9-W 12 are arranged as indicated under Group A in the table. Thus, the PCR pages 0-17, for example, cause selection signal SB 1 L to be asserted, and SB 1 L causes sockets XE53 and XE48 to respond to address signals A<O: 10> H. Other combinations of jumpers are possible, as indicated by Groups B through G in the table. Note that each selection signal always selects the same pair of sockets; however, the relation of PCR pages to selected sockets varies with jumper configuration. 379 peR Group W1 W2 W3 W4 W9 W10 W11 W12 Page Primary Selection Signal (A<O:14>H) Sockets Selected Addresses A R I I R I R R I SB1 L 0-17 20-37 SB2 L 40-47 SE1 L 50-57 SE2 L 360-377 SP1 L 340-357 SP2 L 320-337 SP3L 300-317 SP4L 260-277 SP5L 240-257 SP6L 220-237 SP7 L 200-217 SP8L OK-2K 2K-4K 4K-5K 5K-6K 30K-32K 28K-30K 26K-28K 24K-26K 22K-24K 20K-22K 18K-20K 16K-18K XE53jXE48 XE58jXE44 XE57jXE40 XE52jXE36 XE39jXE50 XE43jXE46 XE47 jXE42 XE51jXE38 XE55jXE37 XE60jXE41 XE59jXE45 XE54jXE49 B .. .. . .. I R I R 40-57 60-77 0-7 10-17 SB1 L SB2 L SE1 L SE2 L 4K-6K 6K-8K OK-1K 1K-2K XE53jXE48 XE58jXE44 XE57 jXE40 XE52jXE36 C .. . .. .. R I R I 200-217 220-237 240-247 250-257 SB1 L SB2 L SE1L SE2 L 16K-18K 18K-20K 20K-21K 21K-22K Ibid. 0 .. .. . . R I I R 240-257 260-277 200-207 210-217 SB1 L SB2 L SE1 L SE2 L 20K-22K 22K-24K 16K-17K 17K-18K Ibid . c.u CD o BDV11 Selection Signals/Sockets (Cont) Primary PCR Selection Addresses Signal (A<O:14>H) Group W1 W2 W3 W4 W9 W10 W11 W12 Page E I R I R · · · · F R I R I · · · · G I R R I · · · · I = inserted; R = removed. 270-277 250-257 230-237 210-217 260-267 240-247 220-227 200-207 Sockets Selected SP1L SP2 L SP3 L SP4 L SP5 L SP6 L SP7 L SP8L 23K-24K 21K-22K 19K-20K 17K-18K 22K-23K 20K-21K 18K-19K 16K-17K XE39/XE50 XE43/XE46 XE47/XE42 XE51/XE48 XE55/XE37 XE60/XE41 XE59/XE45 XE54/XE49 160-177 SP1 L 140-157 SP2 L 120-137 SP3 L 100-117 SP4 L 60-77 SP5 L SP6 L 40-57 SP7 L 20-37 SP8 L 0-17 14K-16K 12K-14K 10K-12K 8K-10K 6K-8K 4K-6K 2K-4K OK-2K Ibid. 70-77 50-57 30-37 10-17 60-67 40-47 20-27 0-7 7K-8K 5K-6K 3K-4K 1K-2K 6K-7K 4K-5K 2K-3K OK-1K Ibid. SP1 L SP2 L SP3 L SP4 L SP5 L SP6 L SP7 L SP8 L M8012 ROM Sockets Logic The following figure represents the ROM sockets and shows the address signals and enabling signals for each functional group of sockets. The diagnostic/bootstrap ROM sockets (which are selected by signals SB 1 Land SB2 L) are supplied with 11 address bits, since these sockets are reserved for 2K-word ROMs. The EPROM sockets (selected by signals SE 1 Land SE2 L) are reserved for 1K ROMs; therefore, these sockets are supplied with 10 address bits. The system ROM sockets can be occupied by either 2K ROMs or 1K ROMs; five jumpers on the BDV 11 module permit ROMs of either size to be used. W7 Al0 H -------o0ow;o----....-- ST2 +12 V =t:: ~ ~ W13 +5V - - - - - - - O : 5 = = r S T 1 ~ CB2 0 W6 ----,----()o ~ DB2 - - - - - ' CAUTION: IMPROPER CONFIGURATION OF THESE JUMPERS MAY CAUSE ROM DAMAGE. BE SURE OF ROM TYPE. The following figure shows how these five i'Jmpers control the selection signals for the system ROM sockets, and relates the jumpers to the types of ROM that can be used in the BDV 11. (If ROMs other than 8316E, 2716, and 2708 are used, do not alter configuration. See Caution.) CAUTION Improper configuration of these jumpers may cause ROM damage. Be sure of ROM type. 382 M8012 W7 Al0 H +12 V I 1 +5V J CB2~ ST2 ~~ W13 ~i i r DB2 ROM TYPE 1. 2 3. 4. ST1 JUMPERS INSERTED' W5 W6 W7 W8 W13 2708 2 R I R I R 2716 R R I R I 8316E3 I R I R R 8316E4 R R I R I I=INSERTED; R=REMOVED CB2 AND DB2 MUST BE SUPPLIED WITH EXTERNAL -5V POWER. CHIP SELECT SIGNALS MUST BE PROGRAMMED AS FOLLOWS: f.§.L ~ LOW LOW CS3 LOW CHIP SELECT SIGNALS MUST BE PROGRAMMED AS FOLLOWS: f.§.L LOW CS2 LOW 383 CS3 HIGH M8013/14 M8013, M8014 RLV11 CONTROLLER Amps +5 + 12 6.5 1.0 Bus Loads Cables AC 3.2 BC08R-XX 70-12122 (1 per drive) DC Transition Bracket Assembly Terminator 70-12415-00 70-12293-00 Standard Addresses CSR BAR DAR MPR 174400 174402 174404 174406 Standard Vectors 160 Diagnostic Programs Refer to Appendix A. 384 M8013/14 1 r--A--, , 15 14 13 I I I I 1 ADDRESS SWITCH 1 1 12 11 1 1 10 09 08 07 00 I I I I I 0 0 1 0 10 1 = SWITCH ON 0= SWITCH OFF Address Selection 0 ,~ 09 15 NOT USED 08 I I 0 07 06 0 1 I 05 04 1 1 03 02 01 0 o 0 00 I I I Io I HARDWIRED VECTOR SWITCH N SWITCH POSITION N =ON F = OFF Vector Selection Related Documentation RL V 11 Controller Technical Description Manual (EK-RL V 11-TO) RL V 11 Field Maintenance Print Set (MP00635) RL01 Field Maintenance Print Set (MP00347) RL02 Field Maintenance Print Set (MP00553) RLO 1 Disk Drive IPB (EK-ORLO 1-IP) RL02 Disk Drive IPB (EK-ORL02-IP) RL01jRL02 User's Guide (EK-RL012-UG) RLO 1jRL02 Pocket Service Guide (EK-RLO 12-PG) Microcomputer Interfaces Handbook (EB-20 175-20) NOTE The M8013 must be installed above the M8014. The RLV11 controllers can only be used in a backplane built as an H9273 (slots A and B = LSI bus and slots C and D = interboard bus). The BA 11-N box currently. is the only box that contains an H9273 backplane. 385 M8013/14 BC06R CABLE RED STRIPE W2 CABLE CONNECTOR TO DRIVE Q rn vco POT 15 KI GND TP o 0 VCI TP o VCO TP COMPONENT SIDE 1 RLV11 DRIVE BOARD MB013 JUMPERS W2 & W4 IN PLACE FOR E PROM USE JUMPERS W1 & W3 IN PLACE FOR MASKED ROM USE W1 o R~~D 0 Q OR W4 W3 EPROM o DV1 DA1 A CY1 CA1 BY1 BA1 NOTE JUMPERS ARE O-OHM COMPOSITION RESISTORS RL V 11 Drive Module (M80 13) 386 AY1 AA1 M8013/14 COMPONENT SIDE 1 RLV11 BUS INTERFACE BOARD M8014 MSBI BUS ADDRESS SWITCH LSB MSB~ VECTOR SWITCH LSB DAl A C D DYl CYl CAl BYl BAl AYl AAl RLV 11 Bus Interface Module (M80 14) CONTROL STATUS REGISTER (CSR) 774400 HCRC ~----R-EA~D~O~N-Ly----~A~------R-E-AD~ffl~R-'T-E-------~ ONLY Control Status Register 387 M8013/14 CSR Bit Definitions Bit Function o Drive Ready (DRDY) - When set, this bit indicates that the selected drive is ready to receive a command (no seek operation in progress). The bit is cleared when a seek operation is initiated and set when the seek operation is completed. 1-3 Function Code - These bits are set by software to indicate the command to be executed. F2 F1 FO Command 0 0 0 0 0 0 0 WRITE CHECK 0 0 0 MAINTENANCE MODE Octal Code 0 0 0 GET STATUS 2 SEEK 3 READ HEADER 4 WRITE DATA 5 READ DATA 6 READ DATA WITHOUT HEADER CHECK 7 Command execution starts when CRDY (bit 7) of the CSR is cleared by software. In a sense, bit 7 can be considered a negative go bit. 4-5 Bus Address Extension Bits (BA 15, BA 17) - Two most significant bus address bits. Read and written as bits 4 and 5 of the CSR, they function as address bits 16 and 17 of the BAR. 6 Interrupt Enable (IE) - When this bit is set by software, the controller is allowed to interrupt the processor at the assertion of CRDY. This occurs at the normal or error termination of a command. Once an interrupt request is posted on the LSI bus, it is not removed until serviced even if IE is cleared. 388 M8013/14 CSR Bit Definitions (Cont) Bit Function 7 Controller Ready (CRDY) - When cleared by software, this bit indicates that the command in bits 1-3 is to be executed. Software cannot set this bit because no registers are accessible while CRDY is O. When set, this bit indicates that the controller is ready to accept another command. 8-9 Drive Select (DSO, DS1) - These bits determine which drive will communicate with the controller via the drive bus. 10 Operation Incomplete (OP!) - When set, this bit indicates that the current command was not completed within the OPI timer period. 11 Data CRC (OCR C) or Header CRC (HCRC) or Write Check (WCE) - If OPI (bit 10) is cleared and bit 11 is set, the CRC error occurred on the data (DCRC). If OPI (bit 10) is set and bit 11 is also set, the CRC error occurred on the header (HCRC). If OPI (bit 10) is cleared and bit 11 is set and the function command was a write check, a write check error (WCE) has occurred. NOTE Cyclic redundancy checking is done only on the desired header. It is performed on the first and second header words, even though the second header word is always O. 12 Data Late (DL T) or Header Not Found (HNF Error) - When OPI (bit 10) is cleared and bit 12 is set, it indicates that a data late condition occurred on a read without header check operation. One of two conditions exists: Write Operation - The silo is empty, but the word count has not reached zero. (Bus request was ignored for too long.) Read Operation - The silo is full (word being read could not enter the silo and the bus request was ignored too long.) When OPI (bit 10) is set and bit 12 is also set, it indicates that a timeout occurred while the controller was searching for the correct sector to read or write (no header; compare [NHFJ). 389 M8013/14 eSR Bit Definitions (Cont) Bit Function Error Summary Error Bit 12 Bit 11 Bit 10 Comments OPI DCRC WCE 0 0 0 0 1 1 1 0 0 HCRC DLT HNF 0 1 1 1 0 0 1 0 1 200 ms timeout Function command is a write check. 13 Nonexistent Memory (NXM) - When set, this bit indicates that during a DMA data transfer, the memory location addressed did not respond within 14 ms. 14 Drive Error (DE) - This bit is buffered from the drive error interface line. When set, it indicates that the selected drive has flagged an error, the source of which can be determined by executing a GET STATUS command. To clear the drive error bit, execute a GET STATUS command with bit 3 of the DAR. 15 Composite Error (ERR) - When set, this bit indicates that one or more of the error bits (bits 10-14) is set. When an error occurs, the current operation terminates and an interrupt routine is initiated if the interrupt enable bit (bit 6 of the CSR) is set. BUS ADDRESS REGISTER (BAR) 774402 BA14 BA12 BA1D READIWRITE Bus Address Register BAR Bit Definitions The Bus Address Register (BAR) is a 16-bit word-addressable register with an address of 774 402. Bits 0 through 15 can be read or written; bit 0 should normally be written O. Expansion bits 16 and 17 are programmable via bits 4 and 5 of the GSA. 390 M8013/14 The bus address register indicates the memory location involved in the DMA data transfer during a read or write operation. The contents of the BAR are automatically incremented by 2 as each word is transferred between system memory and controller in either direction. Clear the BAR by executing a BUS INIT. Disk Address Register (DAR) The Disk Address Register (DAR) is a 16-bit read/write word-addressable register with an address of 774 404. Its contents can have one of three meanings, depending on the function being performed. Clear this register by executing a BUS INIT. DAR During a SEEK Command - To perform a seek function, it is necessary to provide address difference, head select, and head directional information to the selected drive. DAR DURING SEEK COMMAND 15 14 13 12 11 10 09 08 07 DAR SEEK Command Bit Definitions Bits Function o Marker (MRKR) - Must be a 1. Must be a 0, indicating to the drive that a SEEK command is being requested and that the remaining bits in the register will contain the seek specifications. 2 Direction (DIR) - This bit indicates the direction in which a seek is to take place. When the bit is set, the heads move toward the spindle (to a higher cylinder address). When the bit is cleared, the heads move away from the spindle (to a lower cylinder address). The actual distance moved depends on the cylinder address difference (bits 7 -14). 3 Must be a O. 4 Head Select (HS) - Indicates which head (disk surface) is to be selected. Set = lower; clear = upper. 5-6 Reserved. 7 - 14 Cylinder Address Difference (OF <8:0» - Indicates the number of cylinders the heads are to move on a seek. 15 Must be a O. 391 M8013/14 DAR During READ or WRITE DATA Command - For a read, write, or write check operation, the DAR is loaded with the address of the first sector to be transferred. Thereafter, as each adjoining sector is transferred, the DAR is automatically incremented by 1. If the DAR increments to the nonexistent sector address 50 s, an OPI timeout will occur. The drive must then seek to a new track if the transfer is to continue. DAR DURING READING OR WRITING DATA COMMANDS 15 14 13 12 11 10 09 08 07 DAR READ/WRITE DATA Command Bit Definitions Bit Function 0-5 Sector Address (SA<5:0» - Address of one of the 40 sectors on a track. (Octal range is 0 to 47.) 6 Head Select (HS) - Indicates which head (disk surface) is to be selected. Set = lower; clear = upper. 7-14 Cylinder Address (CA<8:0» - Address of one of the 256 cylinders. (Octal range is 0 to 377.) 15 Must be a o. DAR During a GET STATUS Command - After the GET STATUS command is deposited in the CSR, it is the DAR's responsibility to get the command transferred to the drive. Therefore, the DAR must also be programmed along with the CSR to do the GET STATUS command. DAR DURING GET STATUS COMMAND 15 7744041 x 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 0 0 0 0 RST 0 1 1 I x I x Ix Ix I x Ix Ix I I I I I I I I I DAR GET STATUS Command 392 M8013/14 For a GET STATUS command, the DAR register bits must be programmed as follows. DAR Register Bits for a GET STATUS Command Bit Function o Marker (MRKR) - Must be a 1. Get Status (GS) - Must be a 1, indicating to the drive that its status word is being requested. At the completion of the GET STATUS command, the drive status word is read into the controller multipurpose (MP) register (output stage of FIFO). With this bit set, bits 8-15 are ignored by the drive. 2 Must be a O. 3 Reset (RST) - When this bit is set, the drive clears its error register of soft errors before sending a status word to the controller. 4-7 Must be a O. 8-15 Not used. Multipurpose Register (MPR) The MPR is two registers bearing the same base address. When writing into that location, the word counter accepts the data. When reading from that location, the FIFO output buffer provides the data. MPR AFTER GET STATUS COMMAND 15 14 13 12 11 10 09 08 07 06 05 04 03 774406 SKTO MPR Status Word MPR After a GET STATUS Command - When a GET STATUS command is executed and a status word is returned to the controller, the contents of the MPR (FIFO output stage) are defined as follows. 393 M8013/14 Bits 0-2 - State<C:A) CST <C:A» - These bits define the state of the drive. Bits Definition C B A a a a a 1 a 1 a 1 a a a 1 a a a Load Cartridge Spin Up Brush Cycle Load Heads Seek Track Counting Seek Linear Mode (Lock On) Unload Heads Spin Down Bit Definitions Bit Function 3 Brush Home (BH) - Asserted when the brushes are not over the disk. 4 Heads Out (HO) - Asserted when the heads are over the disk. 5 Cover Open (CO) - Asserted when the cover is open or the dust cover is not in place. 6 Head Select (HS) - Indicates the currently selected head. 7 Drive Type (DT) - Set = clear = RLa 1. 8 Drive Select Error (DSE) - Indicates that multiple drive selection was detected. 9 Volume Check (VC) - vc is set every time the drive goes into load heads state. This asserts a drive error at the controller but not on the front panel. VC is an indication that the program does not really know which disk is present until it has read the serial number and bad sector file. (The disk might have been changed while the heads were unloaded.) 1a Write Gate Error (WGE) - Indicates that the drive sensed that write gate was asserted when sector pulse was asserted, or write gate was set with the drive not ready, or the drive was write locked. lower; clear = 394 upper. Set = RLa2; M8013/14 Bit Definitions (Cont) Bit Function 11 Spin Error (SPE) - Indicates that the spindle did not reach speed in the required time; or indicates over speeding. 12 Seek Time Out (SKTO) - Indicates that the heads did not come on track in the required time during a SEEK command or loss of "ready to read/write during lock on" mode. 13 Write Lock (WL) - Indicates write lock status of selected drive. Set = write protected. 14 Head Current Error (HCE) - Indicates that write current was detected in the heads when write gate was not asserted. 15 Write Data Error (WOE) - Indicates that write gate was asserted but no transitions were detected on the write data line. MPR DURING READ HEADER COMMAND 15 WcfRD 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 06 05 04 03 02 01 00 I I I I I I I I I I I I I I I I I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3RD WORD~~~-r~-L~~~~-.~-L~-.~~.-~-L~~ CRC14 CRC12 CRC10 CRC4 CRCO MPR Three Header Words MPR After a Read Header Command - When a READ HEADER command is executed, three words will be stored in the multipurpose register (FIFO output buffer). The first header word will contain sector address (SAO:SA5), head select (HS - set = lower; clear = upper), and cylinder address information (CAO:CA8). The second word will contain all Os. The third word will contain the header CRC information. All three words are readable by the main program. 395 M8013/14 MPR DURING READ/WRITE COMMANDS FOR WORD COUNT 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 774406 we11 MPR Used As Word Counter Bit Definitions Bit Function 0-12 Word Count (WC< 12:0» - 2's complement of total number of words to be transferred. 13-15 Must be a 1 for word count in correct range. MPR During READ/WRITE DATA Commands - When transferring data via DMA, the MPR functions as a word counter and is loaded by program with the 2's complement of the number of words to be transferred. It is then incremented by 1 by the controller as each word is transferred. The reading or writing operation generally is terminated when the word counter overflows. The word counter can keep track of from one data word to the full 40sector count of 5120 data words (decimal). The maximum number of words that can be transferred in a single operation is limited by the number of sectors available to be written in the track. NOTE The RL01/RL02 disk drive will not do spiral read/writes_ If data is to be transferred past the end of the last sector of a track, it is necessary to break up the operation into the following steps. 1. Program the data transfer to terminate at the end of the last sector of the track. 2. Program a seek to the next track. This can be accomplished either by a head switch to the other surface but the same cylinder, or a head switch to move to the next cylinder. 3. Program the data transfer to continue at the start of the first sector on the next track. 396 M8016 M8016 KPV11-A (M8016) POWER FAIL/LINE TIME CLOCK KPV11-B (M8016-YB) KPV11-A + 120 Q TERMINATOR KPV11-C (M8016-YC) KPV11-A + 250 Q TERMINATOR Amps 24 V Bus Loads Cables +5 +12 0.11 0.82 AC 1.6 70-12754 (for remote operation) DC 1.0 Standard Address LKS 177546 Standard Vector LTC 100 Diagnostic Programs Refer to Appendix A. Related Documentation Field Maintenance Print Set (MP00356) Microcomputer Interfaces Handbook (EB-20 175-20) Options to KPV11 DEC PN Description 54-11808 70-11656 70-08612 Console panel printed circuit board assembly Console bezel (dress panel) Console signal/power cable (required for optional console panel use) 397 M8016 EX CL REM DC + t2V o W14 J1 +5V GND W12 W13 R54** W15 o Wll E12 ~--+--+--+- E3 (KPV1-1-B, KPV11-C ONLY) [ E17 (KPV11-B KPV11-C ONLY) . ; MAY USE 4-40 HARDWARE •• = Remoye for 50 Hz operol ion 11-4836 398 M8016 KPV11 Factory Jumper Configuration Jumper Designation Jumper State Function Implemented W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 I I I I I R I I R R Sets address of line time clock status register (lKS) to 177546. W11 W12 Do not change. Must be installed for proper terminator function on KPV 11-8 and KPV 11-C. R Disables continuous or manual control of l TC interrupt request operation. Do not install when W 13 is installed. W13 l TC interrupt requests can be enabled and disabled by program. Do not install when W 12 is installed. W14 Console (optional) l TC ON/OFF switch enabled. W15 l TC signal occurs at the power line frequency. 399 M8016 NOTES 1. 2. 3. 4. Line Time Clock (LTC) controls Function W12 W13 disable LTC enable LTC and enable LTC program control enable LTC and disable LTC program control I R R R I R LTC Remote Console Switch Function W14 console switch enabled console switch disabled I R Select LTC Frequency Function W15 LTC signal occurs at line frequency LTC signal occurs at frequency inserted at EXT TIME REF I R External Transformer The user must supply a 24 Vac, 200 mA center tapped transformer to be connected to the two ac and the ground tabs on the top of the module. If a transformer capable of supplying more than 200 mA is used, current limiting in the form of a fuse must be used to protect the KPV11-A module. LKS (177546) IS 08 07 00 06 BIT 1· ENABLE O'DISABLE (READ/ WRITE BIT) MONITOR SET TO "1" BY LINE FREQUENCY CLOCK SIGNAL. CLEARED BY PROGRAM. (READ/WRITE [CLEAR-ONLY] BIT) Line Time Clock Status Register (lKS) 400 M8016 115vac.60HZ } TO SYSTEM POWER SUPPLY AND FANS * ~-,-------------'GND TO KPV11 24Vac INPUT TERMINALS * GND------------------~.-~ (A) 115V CONNECTIONS (TYPICAL) 230Vac.50Hz } TO SYSTEM POWER SUPPLY AND FANS * r-----~nJ~----... AC ~-,-----------"'GND * ~4_--~~------... TO KPVll 24Vac INPUT TERMINALS AC GND-------------------L~~ (8) 230V CONNECTIONS (TYPICAL) * 1 AMP FAST BLOW FUSES ARE RECOMMENDED ON THE AC INPUT LINES TO PROVIDE ADEQUATE PROTECTION TO THE KPVll. 11- 4839 Power Line Monitor Transformer Installation 401 M8017 M8017 DLV11-E ASYNCHRONOUS SERIAL LINE INTERFACE Amps + 12 t5 1.0 0.15 (0.20 max.) Bus Loads Cables AC 1.26 BC05C DC Standard Address RCSR RBUF XCSR XBUF 175610 175612 175614 175616 NOTE The DLV11-E is shipped configured for use with a modem. Standard Vectors Floating - Configurable within the range of 000-770. Refer to Appendix B. MINC/DECLAB Receiver Interrupt Transmitter Interrupt 300 304 330 334 Diagnostic Programs Refer to Appendix A. Related Documentation DL Vll-E and DLVll-F Asynchronous Line Interface User's Manual (EK-DL V 11-0P) Field Maintenance Print Set (MP00460) Microcomputer Interfaces Handbook (EB-20175-20) 402 M8017 MN ... OMN ... O 1-1-1-1-0:0:0:0: 1'~11111 I As 51 -Foll-FR C1 Ml IBG ---PB OO,...~lt)-.:tM »»» IIIIII IIIIIIIIII N ... OcnOO,...~lt)"'M :(::(::(c:(c:(c:(c(c(c(c( 1f cs- 403 yB H M8017 BDAL 08 5 BITS , ' , 1 07 00 I 1 I ~ BBS7 L ., ell o N ;;;: ;;;: o • CSR 1 • DATA BUFFER } o , LOW BYTE} _ _ _ _- ' 1 • HIGH BYTE RANGE' 1600008 - 1777768 DL V 11-E Addresses I I I I I I L SELECTED BY USER. ASSERTED L~~lbNlIWtu~~T '-\~_ _~ __ ~_-.:~_---=-~_...:..-~ VECTOR JUMPERS, INSTALLED' , REMOVED' 0 O· RECEIVER , • TRANSMITTER CONTROLLED BY INTERRUPT LOGIC CIRCUIT. RANGE' 0 - 7748 DLV 11-E Interrupt Vectors Unit Address Jumpers Address A3 A4 A5 A6 A7 A8 A9 A10A11 A12 Console First Option Second Option Third Option Modem 177560 176500 176510 176520 175610 R R I I I R R R I I R R R R R 404 I I I I R R R R I R R R I I I I R I I R M8017 Unit Vector Vector Jumpers V3 V4 V5 V6 V7 Console 60 First Option 300 Second Option 310 Third Option 320 Modem 300 R R I R R I R R I R I R R R R R I I I I va R R I I I I R R R R Jumper Configuration When Shipped Jumper Designation Jumper State Function Implemented A3 A4 A5 A6 A7 A8 A9 A10 A 11 A12 I R R R I I I R I I Jumpers A3 through A 12 implemented device address 17561 X. The least significant octal digit is hardwired on the module to address the four device registers as follows. V3 V4 V5 V6 V7 V8 R R R I I R This jumper selection implements interrupt vector address 300 for receiver interrupts and 304 for transmitter interrupts. RO R1 R2 R3 I R I I The module is configured to receive at 100 baud (see "Baud Rate Selection" table, which follows). TO T1 T2 T3 I R R R The transmitter is configured for 9600 baud if split slPeed operation is used. BG x = 0 RCSR X = 2 RBUF X = 4 XCSR X = 6 XBUF Break generation is enabled. 405 M80l7 Jumper Configuration When Shipped (Cont) Jumper Designation Jumper State Function Implemented P R Parity bit is disabled. E R Parity type is not applicable when P is removed. 2 R R Operation with eight data bits per character (see "Data Bit Selection" table, which follows). PB R Programmable baud rate function disabled. C C1 Programmable baud rate function disabled. Common speed operation enabled. S S1 R R Split speed operation disabled. H R Halt on framing error disabled. B R I Boot on framing error disabled. -B -FD The DATA TERMINAL READY signal is not forced continuously true. -FR The REQUEST TO SEND signal is not forced continuously true. RS The circuitry controlling the REQUEST TO SEND signal is enabled. FB R The FORCE BUSY signal is disabled. M M1 R R Factory test jumpers. Not defined for field use. 406 M8017 Baud Rate Selection Program Control Receive Jumpers Transmit Jumpers Bit Bit Bit Bit Bit 15 R3 T3 I I I I I I I I R R R R R R R 14 R2 T2 I I I I R R R R I I I I R R R 13 R1 T1 I I R R I I R R I I R R I I R 12 RO TO I R I R I R I R I R I R I R I 11 * Baud Rate 50 75 110 134.5 150 300 600 1200 1800 2000 2400 3600 4800 7200 9600 I = jumper inserted = program bit cleared. R = jumper removed = program bit set. *Bit 11 of the XCSR (write-only bit) must be set in order to select a new baud rate under program control. Jumper PB must be inserted to enable baud rate selection under program control. Data Bit Selection Jumpers Number of Data Bits 2 I I R R I R I R 5 6 7 8 407 M8017 Jumper Definitions Jumper Function A3- A 12 These jumpers correspond to bits 3-12 of the address word. When inserted, they will cause the bus interface to check for a true condition on the corresponding address bit. V3- V8 Used to generate the vector during an interrupt transaction. Each inserted jumper will assert the corresponding address bit on the LSI-11 bus. RO-R3 Receiver and transmitter baud rate jumpers selected during common speed operation. Receiver-only baud rate select jumpers used during split speed operation. TO-T3 Transmitter baud rate select jumpers used during split speed operation. Both receiver and transmitter baud rates used if maintenance mode is entered during split speed operation. BG Jumper is inserted to enable break generation. P Jumper is inserted for operation with parity. E Removed for even parity; inserted for odd parity. Receive checks for appropriate parity and transmitter inserts appropriate parity. 1, 2 These jumpers select the desired number of data bits. PB Jumper is inserted to enable the programmable baud rate capability. C, C1 These jumpers are inserted for common speed operation. (Note that Sand S 1 must be removed when C and C 1 are inserted.) 408 M8017 Jumper Definitions (Cont) Jumper Function S, S 1 Inserted for split speed operation. (Note that C and C 1 must be removed when Sand S 1 are inserted.) H This jumper is inserted to assert BHAL T L when a framing error is received, except when the maintenance bit is set. This places the LSI-11 in the halt mode. B, -B Jumper B is inserted to negate BDCOK H when a BREAK signal or framing error is received, except when the maintenance bit is set. This causes the LSI-11 to reload the bootstrap. (Jumper -B must be removed when B is inserted.) -FD Jumper is removed to force DATA TERMINAL READY signal on. -FR Jumper is removed to force REQUEST TO SEND signal on. RS This jumper is inserted to enable normal transmission of the REQUEST TO SEND signal. FB Inserted to enable transmission of the FORCE BUSY signal (for Bell model 103E data sets). M, M 1 These are test jumpers used during the manufacturing of the module. They are not defined for field use. 409 M8017 DLV11-E RCSR Bit Assignments Bit Function 15 DATA SET INT (Data Set Interrupt) - This bit initiates an interrupt sequence, provided that the DATA SET IN ENB, bit (05) is also set. This bit is set whenever CAR DET, CLR TO SEND, or SEC REC changes state; i.e., on a 0-to-1 or 1-to-0 transition of anyone of these bits. It is also set when ring changes from 0 to 1. Cleared by INIT or by reading the RCSR. Because reading the register clears the bit, it is, in effect, a "read-once" bit. 14 Ring - When set, indicates that a RINGING signal is being received from the dataset. Note that the RINGING signal is not a level but an EIA control with the cycle time as shown below. Read only. MR-0954 13 CLR TO SEND (Clear to Send) - The state of this bit is dependent on the state of the CLEAR TO SEND signal from the data set. When set, this bit indicates an ON condition; when clear, it indicates an OFF condition. Read only. 12 CAR DET (Carrier Detect) - This bit is set when the data carrier is received. When clear, it indicates either the end of the current transmission activity or an error condition. Read only. 11 RCVR ACT (Receiver Active) - When set, this bit indicates that the DLV 11-E's receiver is active. The bit is set at the center of the START bit, which is the beginning of the input serial data from the device, and is cleared by the leading edge of R DONE H. Read-only bit; cleared by INIT or by R DONE H (bit 07). 410 M8017 DLV11-E RCSR Bit Assignments (Cont) Bit Function 10 SEC REC (Secondary Received or Supervisory Received Data) - This bit provides a receive capability for the reverse channel of a remote station. A space (+ 10 V) is read as a 1. (A transmit capability is provided by bit 03.) Read only. 9-8 Not used. Reserved for future use. 07 RCVR DONE (Receiver Done) - This bit is set when an entire character has been received and is ready for transfer to the LSI11. When set, initiates an interrupt sequence, provided that RCVR INT ENB (bit 06) is also set. Cleared whenever the receiver buffer (RBUF) is addressed. Also cleared by INIT. Read only. 06 RCVR INT ENB (Receiver Interrupt Enable) - When set, allows an interrupt sequence to start when RCVR DONE (bit 07) sets. 05 DSET INT ENB (Data Set Interrupt Enable) - When set, allows an interrupt sequence to start when DATA SET INT (bit 15) sets. 04 Not used. Reserved for future use. 03 SEC XMIT (Secondary Transmitted or Supervisory Transmitted Data) - This bit provides a transmit capability for a reverse channel of a remote station. When set, transmits a space (+ 10 V). (A receive capability is provided by bit 10.) Read/write bit; cleared by INIT. 02 REO TO SEND - A control lead to the data set which is required for transmission. Ajumper on the DL V 11-E ties this bit to REO TO SEND or FORCE BUSY in the data set. Read/write bit; cleared by INIT. 01 DTR (Data Terminal Ready) - A control lead for the data set communication channel. When set,permits connection to the channel. When clear, disconnects the interface from the channel. Read/write bit; must be cleared by the program, not by INIT. The state of this bit is not defined after power-up. 00 Not used. Reserved for future use. 411 M8017 14 15 13 12 10 11 09 OS 07 06 RESERVED 05 04 03 02 01 00 RECEIVED DATA SITS DLV11-E RBUF Bit Assignments Bit Function 15 Error - Used to indicate that an error condition is present. This bit is the logical OR of OR ERR, FR ERR, and P ERR (bits 14, 13, and 12, respectively). Whenever one of these bits is set, it causes the error bit to set. This bit is not connected to the interrupt logic. Read-only bit; cleared by removing the error-producing condition. NOTE Error indications remain present until the next character is received, at which time the error bits are updated. INIT clears the error bits. 14 OR ERR (Overrun Error) - When set, indicates that reading of the previously received character was not completed (RCVR DONE not cleared) prior to receiving a new character. Read only; cleared by INIT. 13 FR ERR (Framing Error) - When set, indicates that the character that was read had no valid stop bit. 12 P ERR (Parity Error) - When set, indicates that the parity received does not agree with the expected parity. This bit is always 0 if no parity is selected. Read-only bit; cleared by INIT. 11-08 Not used. Reserved for future use. 07-00 Received Data Bits - Holds the character just read. If fewer than eight bits are selected, then the buffer is right-justified into the least significant bit positions. In this case, the higher unused bit or bits are read as Os. Read-only bits; not cleared by INIT. 15 14 13 12 11 10 09 OB 07 06 05 04 DL V 11-E XCSR Bit Assignments 412 03 02 01 00 M8017 DLV11-E XCSR Bit Assignments Bit Function 15-12 PBR SEL (Programmable Baud Rate Select) - When set, these bits choose a baud rate from 50-9600 baud. Write only. 11 PBR ENB (Programmable Baud Rate Enable) - This bit must be set in order to select a new baud rate indicated by bits 12 to 15. 10-08 Not used. Reserved for future use. 07 XMIT ROY (Transmitter Ready) - This bit is set when the transmitter buffer (XBUF) can accept another character. When set, it initiates an interrupt sequence provided XMIT INT ENB (bit 06) is also set. Read-only bit; set by INIT. 06 XMIT INT ENB (Transmitter Interrupt Enable) - When set, allows an interrupt sequence to start when XMIT ROY (bit 07) is set. Read/write bits; cleared by INIT. 05-03 Not used. Reserved for future use. 02 MAINT Used for maintenance function. When set, connects the transmitter serial output to the receiver serial input while disconnecting the external device from the receiver serial input. It also forces the receiver to run at transmitter baud rate speed when split speed operation is enabled. Read/write bit; cleared by INIT. 01 Not used. Reserved for future use. 00 Break - When set, transmits a continuous space to the external device. Read/write bit; cleared by INIT. 08 L 07 00 TRANSMITTER DATA BUFFER RESERVED DLV11-E XBUF Bit Assignments Bit Function 15-08 Not used or defined. Not necessarily read as Os. 07-00 Transmitter Data Buffer - Holds the character to be transferred to the external device. If fewer than eight bits are used, the character must be loaded so that it is right-justified in the least significant bits. Write-only bits; not necessarily read as Os. 413 M8017 Maintenance Aids The DL V 11 is sh ipped with an H315 modem test connector. This is plugged into the interface cable in place of a data set when maintenance programs are running. Maintenance Mode Logic In the maintenance mode, the DLV11-E and DLV11-F modules route their output data back to their input. To accomplish this, the computer program sets the maintenance bit in the XCSR. The latch holding this bit has two outputs. One goes to the break logic to prevent the generation of framing error signals during operation in the maintenance mode. The other output is applied to the maintenance mode data selector. The data selector normally routes the incoming data from the peripheral interface to the RBUF. In the maintenance mode, however, it switches its input to the output of the XBUF. This action loops the serial data out of the XBUF back into the RBUF and disconnects the peripheral interface's data. While in the maintenance mode, the serial output of the XBUF continues to go to the peripheral interface and out to the peripheral device. MAINTENANCE MODE DATA SELECTOR ~--t-"'S:=-ER,-,-,I.::..:.A=-L..:.;;IN:....:..:...H-..t RBUF MAINT H DAT02 H XCSR BIT 2 CO~~20L REGISTER SELECT MAINT L LOGIC Maintenance Mode Logic 414 M8018 M8018 KUV11-AA WRITABLE CONTROL STORE Amps +5 3 + 12 Bus Loads Cables AC 1.4 17 -00124-00 17 -00124-01 (maintenance) DC Standard Addresses CSR and RAM Address DATA I/O, bits 0-15 DATA I/O, bits 16-21 177540 177542 177544 Standard Vectors None Diagnostic Program Refer to Appendix A. Related Documentation LSI-tt WCS User's Guide (EK-KUV11-TM) KD 11-WA Maintenance Print Set (MP00571-00) NOTES 1. An M8018 can only be used with an M7264-YC LSI-11 processor. 2. To extend the M8018, the maintenance cable is required (17-00124-01 ). 415 M8018 Switch Configurations The range of microcode addresses to which the WCS will respond on the microinstruction bus (MIS) (when the CSR enable bit is a 1) is determined by an 8-wide DIP switch (SW 1) on the M8018 module. Set switches S 1 through S7 (S8 is not used) on SW 1 as shown in the "WCS Address Mode Switch Settings" table to select one of the four modes of operation described below. Mode I - The microcode is loaded from the LSI-11 bus into WCS RAM locations 0 to 1777. The WCS correspondingly responds to microaddresses 2000 to 3777 on the MIS. Mode II - The microcode is loaded from the LSI-11 bus into WCS RAM locations 0 to 1777. The WCS initially responds to MIS microaddresses 3000 to 3777 from the first 512 words of RAM. If bits 21-18 of the microinstruction are coded to a 7 (octal) then the next microinstruction will be accessed from the second 512 words of RAM. A second 7 (octal) will toggle back to the first 512 words of RAM. This swapping between 512 word blocks for the same microaddress range is called "paging" and allows 1024 words of microcode to be implemented when only 512 microaddresses are available. Mode III - This mode is the same as Mode I except that the two blocks of 512 words of RAM have been interchanged on the module. Addressing is identical to that of Mode I. Mode IV - The microcode is loaded from the LSI-11 bus into WCS RAM locations 0 to 1777. The WCS correspondingly responds to MIS microaddresses 0 to 1777. This microaddress space is identical to MICROMs 0 and 1, which contain the base PDP-11 microcode for the LSI-11. 5WITCH 5W1 MODE 51 52 53 54 55 56 57 I ON OFF OFF ON OFF ON OFF - II OFF ON OFF ON OFF OFF ON - 58 III OFF OFF ON ON OFF ON OFF - IV ON OFF OFF OFF ON ON OFF - WCS Address Mode Switch Settings 416 M8018 B wJ B S6 S7 S8 Address Mode Switch Location MODELS ITEM KUV11-UH KD11-WA 11/03-WC 11/03-WD KD11-H CPU X M8018 WCS MODU LE X X X X WCS CABLE Part NO 17-00124-00 X X X X X X X BDV11-AA BOOT MODULE X X BA11-NC BOX (115 V) X KD11-R CPU (Includes MSV11-CD memory) BAll-ND BOX (230V) X Items Supplied Per Configuration 417 M8018 M7264 WCS to CPU Installation LSI-11 Bus Address Decode and Control This logic does the LSI-11 bus interface, and responds to four device addresses which have the following meanings. LSI-11 Address Meaning 177540 Control/status register and RAM address. 177542 Data input/output for RAM data word bits 0-15, or output for trace stack. 177544 Data input/output for RAM data word bits 16-21 and data input/output for two user bits. 177546 Unused (but still responds) A DIN will read all Os. NOTE The address 177546 is the same address normally assigned to the KW 11-L clock status register. Read Back MUX The read back MUX selects the source of the data to be output to the LSI11 bus at the proper time during an LSI-11 DATAl bus cycle. Control Status Register The CSR consists of five control/status bits and a RAM address register. The control/status bits are described below. 418 M8018 eSR Bit Definition 15 When this bit is asserted, it resets the WCS module, in particular, the trace feature. 14, 13, 11 These bits control the trace mode of the WCS. 12 When this bit (the enable bit) is asserted, the WCS is enabled to respond to the MIB. When it is disabled, the WCS cannot respond to the MIB. After the enable bit is disabled in the CSR, the RAM can be accessed by writing an address (with enable bit = 0) to the CSR address. Then the lower 16 bits at that address of RAM (microcode bits 0-15) can be accessed (read or write) at the second device address, and the upper eight bits at the same address of RAM (the two user bits and microcode bits 16- 21) can be accessed (read or write) at the third device address. 177540 READIWRITE TRACE MODE RESET ENABLE BIT EXAMINE UNUSED RAM ADDRESS REGISTER UNDEFINED ENABLE (ALWAYS~O) Control/Status and RAM Address Register MICROCODE LOW WORD RAM Data Input/Output 177542 R EADIWR ITE IF 177540 BIT 14 = 1 1-.._L---L_--I..._...l.-.,...-L----L_--L.._...J...._.l....-----IL---L_....L._...l.-_L----L_-l WCS OUTPUT CYCLE 0= OUTPUT DISABLED 1 = OUTPUT ENABLED Output for Trace Stack 177544 READIWRITE USER BIT AND TRACE STOP RAM Data Input/Output, User Bits Data Input/Output LSI-11 Bit Assignments 419 M8021 M8021 MRV11-BA UV PROM-RAM Amps Cables Bus Loads +5 + 12 AC W/O PROM 0.58 (0.67 max.) 0.34 2.8 1.0 (0.41 max.) With PROMs 0.62 (0.744 max.) 0.5 DC None (0.6 max.) Standard Addresses RAMs PROMs 20000-20777 140000-157777 Standard Vectors None Diagnostic Programs Refer to Appendix A. Related Documentation MRV11-BA LSI-11 UV PROM-RAM User's Manual (EK-MRV11-TM) Field Maintenance Print Set (MP00354) Microcomputer Processor Handbook (EB-18451-20) Recommended PROM Types DEC MRV 11-BC Intel 2708 (DEC PN 23-00087-01) 1024 X 8-bit, MOS, tri-state, erasable ultraviolet (24-pin DIP) 420 M8021 0 HIGH BYTE PROMS ~~~SYTE - + 1ST 1K PROMS 3RD lK PROMS 2ND 1K PROMS 0 o 4TH 1K PROMS o[JG[J 0 oGG[J o-c:::l-O W22 o-c:::J-O W20 } RAM ADDRESS oc:::J-O W19 o-c:::ro W18 BANK 7 ENABLE PROM {o-e::J-o W17 ADDRESS o-e::J-oW16 :~~:LE{§En o-e::::ro W 11 ";;:~~L{E !mg' o-c::::ro W5 ~W4 o-c::roW3 PROM { o-e::::k> W2 ADDRESS o-c:J-o W1 o-c::J-o W21 MRV 11-BA RAM Addressing 421 M8021 W5 JUMPER_ WJ wa W6 W,9 W20 !!! !!!!!! CONF;~~:::~:~-{~ i !!! l! l! FACTORY I 1 R I I R CIRCUITS 1256,01377 BYTE POINTER IDATOB BUS CYCLES ONLYI 0= WRITE LOW BYTE (0,7 ) R 4K AND lK SELECT } , = WRITE HIGH DECODED BY ADDRESSING AND CONTROL LOGIC ~ R· , a l WORDSI 256WORD SELECT R=O 1. Factory configured address range"" 20000 - 20377 2. I ::II Jumper installed; A '" Jumper removed 3. Wl0 removed'" RAM ENABLE Wl0 Installed'" RAM DISABLE MRV 11-BA RAM Addressing 81 TS O_2 -,-_O'--r_O_O.., _~';...7...,.....~~'.:,.5-,-_-r-'...;;.J-,-_'.:,.2..,--,11-r-,-,--,-...;.09'--r_-r_O_7..,-..... 06'--r....;.;;..-,-...;;.04---,_0...,;3-r_ -l I I I I 111 11 l l ! l l ~~,""" {~ ill :g~~!~S '---r--" JUMPER _ W, W2 W,5 iACTORY CONFIGURATION - I I I W17 W'6 • L OECODED BY PROM INTEGRATED CIRCUITS PROM SIZE 11K WITHIN 4K BANKI DECODED BY ADDRESSING AND CONTROL LOGIC.'K SEGMENTS ARE ENABLED VIA Wll-W14, PROM SIZE JUMPER CONFIGURATION W12 W13 NOTES' 1. Factory configured address range'" 140000·157777 2. I '" Jumper Installed; A = Jumper removed MRV 11-BA PROM Addressing 422 W14 M8021 RAM Addressing Summary Memory Jumper Configuration (I = Installed; R = Removed) Address Range (Octal) 000000-000777 001000-001777 002000-002777 003000-003777 004000-004777 005000-005777 006000-006777 007000-007777 010000-010777 o1 1000 - 0 1 1777 012000-012777 013000-013777 014000-014777 015000-015777 016000-016777 017000-017777 020000-020777 021000-021777 022000-022777 023000-023777 024000-024777 025000-025777 026000-026777 027000-027777 030000-030777 031000-031777 032000-032777 033000-033777 034000-034777 035000-035777 036000-036777 037000-037777 040000-040777 041000-041777 042000-042777 043000-043777 044000-044777 045000-045777 046000-046777 047000-047777 Bank W3 W4 WS W6 W7 W8 W9 W19 W20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R R R R R R R R R R R R R R R R R R R R R R R R 2 2 2 2 2 2 2 2 423 I I I I I I I I I I I I I I I I I I I I R R R R R R R R I I I I I I I I I I I I I I I I R R R R R I I I I R R R I I I I I I I I R R R R R R R R R R R R R R R R I I I I R R R R R R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R I I I R R R R R R R R R R R R R R R R R R R R M8021 RAM Addressing Summary (Cont) Address Memory Jumper Configuration (I = Installed; R = Removed) Range (Octal) Bank W3 W4 W5 W6 W7 W8 W9 W19 W20 050000-050777 051000-051777 052000-052777 053000-053777 054000-054777 055000-055777 056000-056777 057000-057777 060000-060777 061000-061777 062000-062777 063000-063777 2 2 2 2 2 2 2 2 3 3 3 3 064000-064777 065000-065777 066000-066777 067000-067777 070000-070777 071000"'071777 072000-072777 073000-073777 074000-074777 075000-075777 076000-076777 077000-077777 100000-100777 101000-101777 102000-102777 103000-103777 104000-104777 105000-105777 106000-106777 107000-107777 110000- 110777 111000-111777 112000-112777 113000-113777 114000-114777 115000-115777 116000-116777 117000-117777 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 R R R R R R R R R R R R R R R R 424 R R R R R R R R I I I I I I I I R R R R R R R R I I I I I I I I R R R R I I I I I I I I R R R I I R I R R R R R R R R R R R R I I I I R R R R R R I I I I R R R R R R R R I I I I I I I I I I I I R R R R R R R R R R R R R R I I R I R I R R I R I I I R I R R R R R I I R I R R R R R R I I I I I I I I R R I R I I R R I I I I I I I I R R I R R R R R R I I I I R R R R I I I R R R I R R R R I R R M8021 RAM Addressing Summary (Cont) Address Memory Jumper Configuration (I = Installed; R = Removed) Range (Octal) Bank W3 W4 W5 W6 W7 W8 W9 W19 W20 120000-120777 121000-121777 122000-122777 123000-123777 124000-124777 125000-125777 126000-126777 127000-127777 130000-130777 131000-131777 132000-132777 133000-133777 134000-134777 135000-135777 136000-136777 137000-137777 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 R R R R R R R R R R R R R R R R 140000-140777 141000-141777 142000-142777 143000-143777 144000-144777 145000-145777 146000-146777 147000-147777 150000-150777 151000-151777 152000-152777 153000-153777 154000-154777 155000-155777 156000-156777 157000-157777 160000-160777 161000-161777 162000-162777 163000-163777 164000-164777 165000-165777 166000-166777 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 7" 7" 7" 7" 7" 7" 7" R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R I I R ~ I I I I R R R R R R R I I R R R R R R R R R I I I I R R I I I I R R I I I I ~ R R R R I I I I I I R R R R R R R R R I I I I I I R R R R R R R R R R R R I I I I I I I I I I I I I I I R R R R R R R I I I I R R R R R R R I I R R R I I R I I I R R R R I I R R R R I I R R R R I I R I R R I I R I I I I I I R "The bank 7 enable jumper W 18 is factory installed to allow addressing in bank 7. 425 M8021 RAM Addressing Summary (Cont) Address Memory Jumper Configuration (I = Installed; R = Removed) Range (Octal) Bank W3 W4 W5 W6 W7 W8 W9 W19 W20 167000-167777 170000-170777 171000-171777 172000-172777 173000-173777 174000-174777 175000-175777 176000-176777 177000-177777 7" 7" 7" 7" 7" 7" 7" 7" 7" R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R I I I I I I R R I I I I R R I R R R R I I R R R R I • The bank 7 enable jumper W 18 is factory installed to allow addressing in bank 7. 426 M8021 NOTE The following jumper configurations illustrate configuring the address range in banks above bank 7 (not implemented in present LSI-11 system configurations). W8, W9, W 19, and W20 can be configured as shown in the preceding pages to select the desired segment within the bank. Address Memory Jumper Configuration (I = Installed; R = Removed) Range (Octal) Bank W3 W4 W5 W6 W7 200000-217777 220000-237777 240000-257777 260000-277777 300000-317777 320000-337777 340000-357777 360000-377777 400000-417777 420000-437777 440000-457777 460000-477777 500000-517777 520000-537777 540000-557777 560000-577777 600000-617777 620000-637777 640000-657777 660000-677777 700000-717777 720000-737777 740000-757777 760000-777777 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 I I I I I I I I R R R R R R R R I I I I I I I R R I R R R R I I I R R I R R R R R R R R R R R R R R R R I I I I I I I I I I I I I I I R R I R R R R I I I R R I I I I I I I I R R I R R R R I I I 427 R R R R R R R R R R R R R R R R R R R R R I R M8021 PROM Addressing Summary Address Memory Jumper Configuration (I = Installed; R = Removed) Range (Octal) Bank 000000-017777 020000-037777 040000-057777 060000-077777 100000-117777 120000-137777 140000-157777 160000-177777 200000-217777 220000-237777 240000-257777 260000-277777 300000-317777 320000-337777 340000-357777 360000-377777 400000-417777 420000-437777 440000-457777 460000-477777 500000-517777 520000-537777 540000-557777 560000-577777 600000-617777 620000-637777 640000-657777 660000-677777 700000-717777 720000-737777 740000-757777 760000-777777 0 1 2 3 4 5 6 7* 10 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 30 31 32 33 34 35 36 37 W1 W2 W15 W17 W16 I I I I I I I I R R R R R R I I I I R R I I I I R R I I I I R R I I I I R R I I I I R R R R R R R R R R R R R R R R R R R R R R R R I I I I I I I I R R R R R R R R I I I I R R R R I I I I R R R R I I I I R R R R I I I I R R R R R R R R R R R R I R I I I R R I I I I R R I I I I *The bank 7 enable jumper W18 is factory installed to allow addressing in bank 7. 428 R R R R R M8021 PROM Addressing Address* Octal Binary 0 2 4 6 10 12 14 10090807060504030201 Address Bits 22 23 1 2 3 4 5 6 7 8 PROM Pins 00000000000 L 00000000010 L 00000000100 L 00000000110 L 00000001000 L 00000001010 L 3776 11111111110 H L L L L L L L L L L L L H H L L L L L L L L L L L L L L L L L L L L L L L L H H H H L L L L H H L L L H H L H H L L L H Actual Logic Levels Required (1024 10 Locations) H H H *Bus address bit 0 is not used. Therefore, only even-numbered addresses are shown. 429 M8027 M8027 LPV11 LP05/LA180 INTERFACE MODULE Amps +5 0.8 Bus Loads + 12 0 AC 1.4 I LPZS Cables DC BC 11 S-25 for LA 180 70-11212-25 for LP05 Standard Addresses LPCS LPDB 177514 177516 Standard Vector Done or error interrupt 200 Diagnostic Programs Refer to Appendix A. Related Documentation LP25 Line Printer Maintenance Guide (ER-OLP25-5V) LPVII Printer User's Manual (EK-LPV 11-0P) LA 180 DECprinter I User's Manual (EK-LA 180-0P) LA 180 Field Maintenance Print Set (MP-LA 180-00) LA 180 DECprinter I Maintenance Manual (EK-LA 180-MM) LP05 Technical Manual, Model 2230 Line Printer (Dataproducts Corporation) LPV 11-V Field Maintenance Print Set (MP00467) Microcomputer Interfaces Handbook (EB-20175-20) NOTE The LPV11 (M8027) is a direct replacement for the LAV11 (M7949). 430 M8027 I 1~~.'MN w6A !mH pI Ow, W14 Jl > > »» F+ V7 ~ 2. 2. 2. > »»> W4 W3 ~2~Y i :;::;::;:~ ~ bb6~ & ~ III V <1:<1: TI ~W7 W,} NOTE: i ~JHUE~:E~~R~~::pN J~~~ECRL;~~~L~NN~~I~:~~~RBEE ~ USED TO REPLACE PREVIOUSLY REMOVED FACTORY INSTALLED (W) JUMPERS (SHOWN INSTALLED). o =WIRE WRAP PIN. 431 W13 W12 Wll Wl0 W9 M8027 DEVICE ADD::: ~,."";';'-r-,;,;;"",r:""'''''';';'-,-''';;;''''-:~'''';;:'''''';';'''-r-;,;""r,.-=,.-~....==-r-=':'-r-''::'''' FDRMAT L-~--~~~~~~~~-r~~~-L'-~~~~~-r~~ FACTDRY CD~~U~~7~1~~ LPDa - 177518 R I t + t I I I t + t + + + + I I I I I AU All Al0 All AS A7 (W41 AS AS (W31 A4 (W2j I A3 JUMPER (FACTDRY INSTALLEDI I-INSTALLED-LDGICAL-O R-REMOVED-LOGICAL-l LPV 11 Interrupt Device Address Format and Jumpers BITS VECTOR ADDRESS FORMAT 15 II 0 14 09 0 FACTORY CONFIGURATIDN I-INSTALLED-LOGICAL 0 R-REMOVED-LOGICAL 1 07 0 1 I R 08 06 04 03 02 01 00 0 o 0 o o o I I I I I I I I I I I I I 1111111 l ! ! ! !! l 0 - 200 08 JUMPER (FACTORY INSTALLEDI VB (W141 0 I va V4 V5 V3 !W131 (W121 (Will (Wl01 V2 (wei LPV 11 Vector Address Format and Jumpers LPV 11 Jumper Definitions Jumper Designation Configuration When Shipped A12 A 11 A10 R R R R R I A9 AS A7 A6 A5 A4 A3 VS V7 V6 V5 V4 V3 V2 Function Jumper wires W2, W3, and W4 are factory installed to negate address bits 4, 5, and 7, respectively. This sets 177514 as the base address. R I I R I R I I I I I Jumper wires W9 through W 14 are factory installed to negate vector bits 2, 3, 4, 5,6, and S. This sets 200 as the interrupt vector. 432 M8027 LPV11 Jumper Definitions (Cont) Jumper Designation Configuration When Shipped D Function W 1 installed to delay BRPL Y L. T W7 R I Supports both uppercase and lowercase printing. For uppercase only, remove W7 and install T. Do not configure the module with both jumpers W7 and T installed. P R W8 I Configured to transmit parity (bit 07) to printer. Parity Option Jumper WS Jumper P Normal parity bit No parity, bit 07 low No parity, bit 07 high Installed Removed Removed Removed Removed Installed Do not configure the module with both jumpers W8 and P installed. NOTE If the LPV 11 interface module is used with an LP05 printer equipped with the Direct Access Vertical Form Unit (DAVFU), it is recommended that the user remove jumper WS. The LP05 interface module does not support the DAVFU Function. F- F+ R a W6 is installed at F + to enable error filter operation with the LP05. For operation without the error filter, remove W6 and install a jumper at F - . Do not configure the module with jumpers installed at both F + and F - . The I!A 180 automatically enables the error filter circuit regardless of the jumper configuration. 433 M8027 LPCS y (NOT USEDI ERROR (READONLVI y (NOT USEDI DONE (READ ONLVI ON LINE IREAD·ONL VI INTERRUPT ENABLE (READ/WRITEI BUSV (READ·ONL VI MR·0823 LPV 11 Control/Status Register (LPCS) LPCS Register Bit Functions Bit Function 15 Error - Asserted (1) whenever an error condition exists in the line printer. Error conditions include the following. LP05 errors: • • • • • • • Power off No paper Printer drum gate open Over-temperature alarm PRINT INHIBIT switch off Printer off-line Torn paper LA 180 errors: • • Fault (paper fault) ON-LINE switch (in OFF position) Reset by manual correction of error condition if LPCS bit 06 is not set. If bit 06 is set, bit 15 is reset by manual correction of the error and (1) reading the interrupt vector if the interface is "ready," or (2) after reading the LPCS if the interface is "not ready." Read only. 14-08 Not used. Read as Os. 434 M8027 LPCS Register Bit Functions (Cont) Bit Function 07 Done LP05 - Asserted (1) whenever printer is ready for next character to be loaded. Indicates that previous function is either complete or has been started and continued to a point where the printer can accept the next command. This bit is set by the LSI-11 processor asserting BINIT L; if bit 06 is also set, an interrupt sequence is initiated. Also set by the printer when on-line and ready to accept a character. Cleared by loading (writing into) the LPDB register. Inhibited when bit 15 is set. Read only. LA 180 - Asserted (1) when the printer is ready to accept another character. Done is set by the LSI-11 processor asserting BINIT L and is cleared by loading (output transfer to) the LPDB register. If the interrupt enable bit is set, setting done will initiate an interrupt request. 06 Interrupt Enable - Set or cleared by the program. Also cleared by the LSI-11 processor asserting BINIT L. When set, an interrupt sequence is initiated if either the error or done bit is set. 05-02 Not used. Read as Os. 01 On-Line - Not supported and not required by DEC software. 00 Busy - Not supported and not required by DEC software. The following information is for reference only. LA 180 - Set when the LA 180 prints a line or advances paper. LP05 - Not used. Read as O. 435 M8027 08 07 00 I I I I I I I I I I I I I I I LPoB y (NOT USEol \ PARITY 07 OR 08 (OR PAPER INSTRUCTION FOR LPOSl 05 06 04 03 02 01 . (REAOIWRITEl MA-0824 LPV 11 Data Buffer Register (LPDB) LPDB Register Bit Functions Bit Function 15-08 Not used. Read as Os. Data written into these bits is lost. 07 Parity or 08 - Optional use. Read as o. LA 180 - Optional parity bit. LP05 - Optional paper instruction bit. Not supported by the LPV 11 (read as 0). 06-00 Data - Seven-bit ASCII character register. Characters are sequentially output to the printer buffer via this register. Read as all Os. 436 M8028 M8028 DLV11-F ASYNCHRONOUS SERIAL LINE INTERFACE Amps +5 1.0 + 12 0.18 Bus Loa(is Cables AC 2.2 BC05M for 20 mA BC05C for EIA modem BC05C plus H312A for EIA terminal DC 1.0 Standard Addresses RCSR RBUF XCSR XBUF Second Console Terminal Modem MINC/DECLAB 177560 177562 177564 177566 175610 175612 175614 175616 176500 176502 176504 176506 175610 175612 175614 175616 Standard Vectors Floating - Configurable in the range of 000-770. Refer to Appendix B. Receiver Transmitter Second Console Terminal Modem MINC/DECLAB 60 64 330 334 300 304 300 304 Diagnostic Programs Refer to Appendix A. Related Documentation DL V 11-E and DL V 11-F Asynchronous Line Interface User's Manual (EK-DLV 11-0P) Field Maintenance Print Set (MP00461) Microcomputer Interfaces Handbook (EB-20175-20) 437 M8028 'III Ii C-___~ IEF I PB N~O ---cnCO""f.DIJ')'I::t'M rrrrnnn I lBG MT M.ql/)cD,...CO frnrr lH IB IB MR-2696 DL V 11-F Etch Rev B Jumper Locations 438 M8028 [ 1 J1 _4P _4A _3P _5A _R3 _R2 _Rl _RO _2P _2A _ _ lP -lA -B --B _H -----..Sl -----..TO -----..Tl -----..T2 -----..T3 _ _ Cl _EF _Ml _C _ S --E -----.. 1 _2 _P _A12 _All _ _ 3A _M _BG _MT _V5 -V _ _6 V7 _A7 --A6 -A5 -----..Al0 _A9 -----..A8 _V8 _A4 _A3 _V4 _V3 _PB _BPl _AAl _ABl DL V 11-F Etch Rev C Jumper Locations 439 M8028 BDAl BITS 15 \1 08 D7 00 II I I I o ;;; o • CSR I ,DATA BUFFER ) o • lOW BYTE) _ _ _-----.J I • HIGH BYTE RANGE· 1600008 - 1777768 DL V 11-F Addresses Address Jumpers Address Unit Console 177560 First Option 176500 Second Option 176510 176520 Third Option 175610 Modem A12 R R A 11 A10 A9 Aa A7 A6 AS A4 A3 I I R R R R I R R R I I R I I I I R R R R R I I I I I I R R R I I I I I R I Etch Rev C BD1 R AA1 R AB1 R Vector Jumpers Unit Vector va V7 V6 VS V4 V3 Console First Option Second Option Third Option Modem 60 300 310 320 300 R R I R R 440 I I R R R R R R R R I I I I I I I I I R R R R R R I I I I I I I I I I M8028 00 08 L 0, RECEIVER I 'TRANSMITTER VECTOR JUMPERS' INSTALLED'I REMOVED, 0 CONTROLLED BY INTERRUPT LOGIC CIRCUIT RANGE· 0 -7748 DLV 11-F Interrupt Vectors Jumper Configuration When Shipped Jumper Designation A3 A4 A5 A6 A7 A8 A9 A10 A 11 A12 Jumper State R I I I R Function Jumpers A3 through A 12 implement device address 17756X. The least significant octal digit is hardwired on the module to address the four device registers as follows. I x o RCSR I I I X X X 2 4 RBUF 6 XBUF V3 V4 V5 V6 V7 V8 I R R I I I This jumper selection implements interrupt vector address 60 for receiver interrupts and 64 for transmitter interrupts. TO I R R R The transmitter is configured for 9600 baud if split speed operation is used. P I R Break generation is enabled. Parity bit is disabled. E R Parity type is not applicable when P is removed. T1 T2 T3 BG XCSR 441 M8028 Jumper Configuration When Shipped (Cont) Jumper Designation Jumper State Function 1 2 R R Operation with eight data bits per character. (See "Data Bit Selection" table.) PB R Programmable baud rate function disabled. Common speed operation enabled. C C1 S S1 R R Halt on framing error enabled. H B B R Boot on framing error disabled. I 1A 2A 3A 1P 2P I I I 4A 5A 3P 4P I I The 20 rnA current loop receiver is configured as an active receiver. R R The 20 rnA current loop transmitter is configured for active operation. R R Error flags disabled. EF M M1 MT Split speed operation disabled. R R R Factory test jumpers. Not defined for field use. Maintenance bit disabled. 442 M8028 Baud Rate Selection Program Control Receive Jumpers Transmit Jumpers Bit Bit Bit Bit Bit 15 R3 T3 I I I I I I I I R R R R R R R R 14 R2 T2 I I I I R R R R I I I I R R R R 13 R1 T1 I I R R I I R R I I R R I I R R 12 RO TO I R I R I R I R I R I R I R I R 11 • Baud Rate 50 75 110· • 134.5 150 300 600 1200 1800 2000 2400 3600 4800 7200 9600 19200 I = jumper inserted = program bit cleared. R = jumper removed = program bit set. Bit 11 of the XCSR (write-only bit) must be set in order to select a new baud rate under program control. Also, jumper PB must be inserted to enable baud rate selection under program control. When configured for 110 baud, the UART is set for two stop bits. 443 M8028 Data Bit Selection Jumpers Number of Data Bits 2 I I R R I R I R 5 6 7 a Jumper Definitions Jumper Function A3-A 12 These jumpers correspond to bits 3-12 of the address word. When inserted, they will cause the bus interface to check for a true condition on the corresponding address bit. V3- va Used to generate the vector during an interrupt transaction. Each inserted jumper will assert the corresponding vector address bit on the LSI-11 bus. RO-R3 Receiver and transmitter baud rate jumpers selected during common speed operation. Receiver-only baud rate select jumpers used during split speed operation. TO-T3 Transmitter baud rate select jumpers used during split speed operation. Both receiver and transmitter baud rates used if maintenance mode is entered during split speed operation. BG Jumper is inserted to enable break generation. P Jumper is inserted for operation with parity. E Removed for even parity; inserted for odd parity. Receiver checks for appropriate parity and transmitter inserts appropriate parity. 1, 2 These jumpers select the desired number of data bits. PB Jumper is inserted in order to enable the programmable baud rate capability. 444 M8028 Jumper Definitions (Cont) Jumper Function C,C1 These jumpers are inserted for common speed operation. Note that Sand S 1 must be removed when C and C 1 are inserted. S, S1 Inserted for split speed operation. Note that C and C 1 must be removed when Sand S 1 are inserted. H This jumper is inserted to assert BHAL T L when a framing error is received, except when the maintenance bit is set. This places the LSI-11 in the halt mode. B,B Jumper B is inserted to negate BDCOK H when a BREAK signal or framing error is received, except when the maintenance bit is set. This causes the LSI-11 to reload the bootstrap. (Jumper B must be removed when B is inserted.) 1A,2A, 3A These three jumpers are inserted to make the 20 mA and 3A current loop receiver active. (Jumpers 1P and 2P are removed when 1A, 2A, and 3A are inserted.) 1P, 2P These jumpers are inserted to make the 20 mA current loop receiver passive. (Jumpers 1A, 2A, and 3A must be removed when 1P and 2P are installed.) 4A, 5A Inserted to make the 20 mA current loop transmitter active. (3P and 4P must be removed when 4A and 5A are inserted.) 3P, 4P Inserted to make the 20 mA current loop transmitter passive. (4A and 5A must be removed when 3P and 4P are inserted.) EF Jumper is removed to enable the error flags to be read in the high byte of the receiver buffer. MT When inserted, enables maintenance bit. M,M1 These are test jumpers used during the manufacturing of the module. They are not defined for field use. 445 M8028 1t - 4965 DL V 11-F RCSR Sit Assignments DLV11-F RCSR Bit Assignments Bit Function 15-12 Not used. Reserved for future use. 11 Receiver Active (RCVR ACT) - When set, this bit indicates that the DL V 11-F interface receiver is active. The bit is set at the center of the start bit, which is the beginning of the input serial data from the device, and is cleared by the leading edge of ROaNE H. 10-08 Not used. Reserved for future use. 07 Receiver Done (RCVR DONE) - This bit is set when an entire character has been received and is ready for transfer to the LSI11 bus. When set, initiates an interrupt sequence provided RCVR INT ENS (bit 06) is also set. Read-only bit; cleared whenever the receiver buffer (RSUF) is addressed or whenever RDR ENS (bit 00) is set. Also cleared by INIT. 06 Receiver Interrupt Enable (RCVR INT ENS) - When set, allows an interrupt sequence to start when RCVR DONE (bit 07) sets. Read/write bit; cleared by INIT. 05-01 Not used. Reserved for future use. 00 Reader Enable (RDR ENS) - When set, this bit advances the paper-tape reader in DIGITAL-modified TTY units (L T33-C; L T35-A, -C) and clears the done bit (bit 07). This bit is cleared at the middle of the start bit, which is the beginning of the serial input from an external device. Also cleared by INIT. Write only. 446 M8028 14 13 12 11 10 09 08 07 06 RESERVED 05 04 03 02 01 00 RECEIVED DATA BITS DLV11-F RBUF Bit Assignments Bit Function 15 Error - Used to indicate that an error condition is present. This bit is the logical OR of OR ERR, FR ERR, and P ERR (bits 14, 13, and 12, respectively). Whenever one of these bits is set, it causes the error bit to set. This bit is not connected to the interrupt logic. Read-only bit; cleared by removing the error condition. NOTE Error indications remain present until the next character is received, at which time the error bits are updated. INIT clears the error bits. 14 Overrun Error (OR ERROR) - When set, indicates that the reading of the previously received character was not completed (RCVR DONE not cleared) prior to receiving a new character. Read-only bit; cleared by INIT. 13 Framing Error (FR ERR) - When set, indicates that the character that was read had no valid stop bit. Read-only bit; cleared by INIT. 12 Parity Error (P ERR) - When set, indicates that the parity received does not agree with the expected parity. This bit is always 0 if no parity is selected. 11-08 Not used. Reserved for future use. 07-00 Received (Data Bits) - Holds the character just read. If fewer than eight bits are selected, then the buffer is right-justified into the least significant bit positions. Then, the higher unused bit or bits are read as Os. Read-only bits; not cleared by INIT. 447 M8028 iO 09 08 07 06 05 04 03 02 Ot 00 RESERVED RESERVED DLV11-F XCSR Bit Assignments Bit Function 15-12 Programmable Baud Rate Select (PBR SEL) - When set, these bits choose a baud rate from 50-9600 baud. Write only. 11 Programmable Baud Rate Enable (PBR ENB) - This bit must be set in order to select a new baud rate indicated by bits 12 to 15. Write only. 10-08 Not used. Reserved for future use. 07 Transmitter Ready (XMIT ROY) - This bit is set when the transmitter buffer (XBUF) can accept another character. When set, it initiates an interrupt sequence provided XMIT INT ENB (bit 06) is also set. 06 Transmitter Interrupt Enable (XMIT INT ENB) - When set, allows an interrupt sequence to start when XMIT ROY (bit 07) is set. Read/write bits; cleared by INIT. 05-03 Not used. Reserved for future use. 02 MAINT - Used for maintenance function. When set, connects the transmitter serial output to the receiver serial input while disconnecting the external device from the receiver serial input. It also forces the receiver to run at transmitter baud rate speed when split speed operation is enabled. Read/write bit; cleared by INIT. 01 Not used. Reserved for future use. 00 Break - When set, transmits a continuous space to the external device. Read/write bit; cleared by INIT. 448 M8028 08 15 07 00 TRANSMITTER DATA BUFFER RESERVED 11·5155 DLV11-F XBUF Bit Assignments Bit Function 15-08 Not used. Not. defined. Not necessarily read as Os. 07-00 Transmitter Data Buffer - Holds the character to be transferred to the external device. If fewer than eight bits are used, the character must be loaded so that it is right-justified into the least significant bits. 449 M8029 M8029 RXV21 FLOPPY DISK CONTROLLER Amps +5 1.8 + 12 Bus Loads Cables AC 3.0 BC05L-15 DC 1.0 Standard Addresses RXCS RXDB First Controller Second Controller 177170 177172 177200 177202 Standard Vectors 264 270 Diagnostic Programs Refer to Appendix A. Related Documentation RXV21 Field Maintenance Print Set (MP00628) RX02 Floppy Disk System User's Guide (EK-RX02-UG) RXO 1/RX02 Reference Card (EK-RX 102-RC) RX02 Technical Manual (EK-ORX02-TM) Minicomputer Interfaces Handbook (EB-20 175-20) RX02 Field Maintenance Print Set (MP-00629-00) CAUTION PDP-11/23 systems require the M8029 to be at CS revision E1 or higher. 450 M8029 BC05L-15 CABLE CONNECTION c 1 O--OA3 0--0 A 120--0 A4 0--0 V2 0--0 A5 o OV3 O--OA6 O--OV4 0 OAl O--OV5 0 OAB o OV6 O--OA9 0--0 Vl O--OA10 o OVB O--OA11 M8029 Module Address and Vector Jumpers 451 M8029 STANDARD ADDRESSES 15 14 12 11 10 1 : : 1 1 12 11 10 13 177170 DTHE R 177200 1 1 1 1 1 1 : : : : : : : : : : 0 0 1 1 STANDARD VECTOR ADDRESS 15 14 13 264 OTHER 270 RX2BA 177172 STARTING MEMORY ADDRESS OF DATA RXDB 177172 NOT USED DATA BYTE RXV21 Error Codes Error Reg Error Codes 15141312111098 7 Track addr sel DV DV DEN HD DEN SEL DV1 LD DVO 6 5 4 3 2 Target Sector Target Track Current Track DV 1 Current Track DVO Word Count Reg Error Code 1 0 DEN CMD The following sequence is used to get definitive error information following a bootstrap operation. (It is assumed that the bootstrap program has halted and the CPU is in ODT.) 1. Examine R5 (RF will contain RXES after an error). 2. Examine RXER by: • Loading the READ ERROR REGISTER command (777170/XXXXXX 17<CR». into RX2CS • Examining the four words of error information that will be transferred into locations 2000, 2002, 2004, and 2006. • Reading and decoding this information using the format shown below. The error code can be used to help identify the failing FRU. 452 M8029 DONE RX2CS Format RXV21 Bit Definitions Bit Function o Go - Initiates a command to RX02. Write only. 1-3 Function Select - These bits code one of the eight possible functions described below. Write only. Code Function 000 001 010 011 100 101 110 111 Fill Buffer Empty Buffer Write Sector Read Sector Set Media Density Read Status Write Deleted Data Sector Read Error Code 4 Unit Select - This bit selects one of the two possible disks for execution of the desired function. This bit is readable only when done is set, at which time it indicates the unit previously selected. Read/write. 5 Done - This bit indicates the completion of a function. Done will generate an interrupt when asserted if interrupt enable (RX2CS bit 6) is set. Read only. 6 Interrupt Enable - This bit is set by the program to enable an interrupt when the RX02 has completed an operation (done). The condition of this bit is normally determined at the time a function is initiated. Read/write; cleared by initialize. 7 Transfer Request - This bit signifies that the RXV21 needs data or has data available. Read only. 8 Density - This bit determines the density of the function to be executed. This bit is readable only when done is set, at which time it indicates the density of the function previously executed. Read/write. 453 M8029 Bit Definitions (Cont) Bit Function 9 Head Select - This bit selects one of two heads for double-sided operation, readable only when done is set. At that time the side that was previously selected is not valid. 10 Reserved for future use. Must be written as a o. 11 RX02 - This bit is set by the interface to inform the programmer that this is an RX02 system. Read only. 12-13 Extended Address - These bits are used to declare an extended bus address. Write only. 14 RXV21 Initialize - This bit is set by the program to initialize the RXV21 without initializing all devices on the UNIBUS. Write only. CAUTION Loading the lower byte of the RX2CS will also load the upper byte of the RX2CS. Upon setting this bit in the RX2CS, the RXV21 will negate done and move the head position mechanism of both drives (if two are available) to track o. Upon completion of a successful initialize, the RX02 will zero the error and status register, and set initialize done. It will also read sector 1 of track 1 on drive 0 into the buffer. 15 Error - This bit is set by the RX02 to indicate that an error has occurred during an attempt to execute a command. Read only; cleared by the initiation of a new command or an initialize. 15 14 13 12 11 10 09 08 07 06 05 I0 I t 04 03 02 01 00 . 0-114. NOT USED RX2TA Format (RXV21) RX2TA (RX Track Address) - This register is loaded to indicate on which of the 1148 (0-76 10 ) tracks a given function is to operate. It can be addressed only under the protocol of the function in progress. Bits 8- 15 are unused and are ignored by the control. 454 M8029 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 NOT USED RX2SA Format (RXV21) RX2SA (RX Sector Address) - This register is loaded to indicate on which of the 328 (1-26 10 ) sectors a given function is to operate. It can be addressed only under the protocol of the function in progress. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 1~lol RX2WC Format (RXV21) RX2WC (RX Word Count Register) - For a double-density sector, the maximum word count is 128 10 , For a single-density sector the maximum word count is 64 10 , If a word count is beyond the limit for the density indicated, the control asserts word count overflow (bit 10 of RX2ES). This is a writeonly register. The actual word count, and not the 2's complement of the word count, is loaded into the register. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 RX2BA and RX2DB Format (RXV21) RX2BA (RX Bus Address Register) - This register specifies the bus address of data transferred during fill buffer, empty buffer, and read definitive error operations. Incrementation takes place after a memory transaction has occurred. The RX2BA, therefore, is loaded with the address of the first data word to be transferred. This is a 16-bit, write-only register. RX2DB (RX Data Buffer) - All information transferred to and from the floppy media passes through this register and is addressable only under the protocol of the function in progress. RX2DB (Data Buffer Register [177172]) - This register serves as a general purpose data path between the RX02 and the interface. It may represent one of six RX02 registers according to the protocol of the function that is in progress. 455 M8029 This register is read/write if the RX02 is not in the process of executing a command; that is, it may be manipulated without affecting the RX02 subsystem. If the RX02 is actively executing a command, this register will only accept data if RX2CS bit 7 (TR) is set. In addition, valid data can only be read when TR is set. CAUTION Violation of protocol in manipulation of the data buffer register may cause permanent data loss. 15 14 13 12 11 DD WC OVFL DEN ERR HD SEL CRC SIDE 1 RDY RX2ES Format (RXV21) RX2ES (RX Error and Status) - This register contains the current error and status conditions of the drive selected by bit 4 (unit select) of the RX2CS. This read-only register can be addressed only under the protocol of the function in progress. The RX2ES is located in the RX2DB upon completion of a function. RXES bit assignments are as follows. Bit Definitions Bit Function o CRC Error - A cyclic redundancy check error was detected as information was retrieved from a data field of the diskette. The data collected must be considered invalid. The RX2ES is moved to the RX2DB, and error and done are asserted. It is suggested that the data transfer be tried up to 10 times, as most errors are recoverable (soft). Side 1 Ready - This bit, when set, indicates that a double-sided diskette is mounted in a double-sided drive and is ready to execute a function. This bit is valid only at the termination of an initialize sequence or a maintenance READ STATUS command. 456 M8029 Bit Definitions (Cont) Bit Function 2 Initialize Done - This bit is asserted in the RX2ES to indicate completion of the initialize routine which can be caused by RX02 power failure, system power failure, or programmable or bus initialize. 3 RX AC LO - This bit is set by the interface to indicate a power failure in the RX02 subsystem. 4 Density Error - This bit indicates that the density of the function in progress does not match the drive density. Upon detection of this error the control terminates the operation and asserts error and done. 5 Drive Density - This bit indicates the density of the diskette in the drive selected (indicated by bit 8). The density of the drive is determined during read and write sector operations. 6 Deleted Data - This bit indicates that in the course of recovering data, the "deleted data" address mark was detected at the beginning of the data field. The DRV DEN bit indicates whether the mark was a single- or double-density deleted data address mark. The data following the mark will be collected and transferred normally, as the deleted data mark has no further significance other than to establish drive density. Any alteration of files or actual deletion of data due to this mark must be accomplished by user software. 7 Drive Ready - This bit indicates that the selected drive is ready if bit 7 = 1 and all conditions for disk operation are satisfied, such as door closed, power OK, diskette up to speed, etc. The RX02 may be presumed to be ready to perform any operation. This bit is only valid when retrieved via a read status function or initialize. 8 Unit Select - This bit indicates that drive 0 is selected if bit 8 = O. This bit indicates the drive that is currently selected. 9 Head Select - This bit indicates which side of a double-sided drive performed the last operation. 10 Word Count Overflow - This bit indicates that the word count is beyond sector size. The fill or empty buffer operation is terminated and error and done are set. 11 Nonexistent Memory Error - This bit is set by the interface when a DMA transfer is being performed and the memory address specified in RX2BA is nonexistent. 457 M8029 Function Codes Following the strict protocol of the individual function, data storage and recovery on the RXV21 occur with careful manipulation of the RX2CS and RX2DB registers. The penalty for violation of protocol can be permanent data loss. A summary of the function codes is presented below. 000 001 010 011 100 101 110 111 Fill Buffer Empty Buffer Write Sector Read Sector Set Media Density Read Status Write Deleted Data Sector Read Error Code The following paragraphs describe in detail the programming protocol associated with each function encoded and written into RX2CS bits 1-3 if done is set. Fill Buffer (000) - This function is used to fill the RX02 data buffer with the number of words of data specified by the RX2WC register. Fill buffer is a complete function in itself: the function ends when RX2WC overflows, and if necessary, the control has zero-filled the remainder of the buffer. The contents of the buffer may be written on the disk by means of a subsequent WRITE SECTOR command or returned to the host processor by an EMPTY BUFFER command. If the word count is too large, the function is terminated, error and done are asserted, and the word count overflow bit is set in RX2ES. To initiate this function the RX2CS is loaded with the function. Bit 4 of the RX2CS (unit select) does not affect this function since no disk operation is involved. Bit 8 (density) must be properly selected since this determines the word count limit. When the command has been loaded, the done bit (RX2CS bit 5) goes false. When the TR bit is asserted, the RX2WC may be loaded into the data buffer register. When TR is again asserted, the RX2BA may be loaded into the RX2DB. The data words are transferred directly from memory and when RX2WC overflows and the control has zero-filled the remainder of the sector buffer, if necessary, done is asserted, ending the operation. If bit 6 RX2CS (interrupt enable) is set, an interrupt is initiated. Any read of the RX2DB during the data transfer is ignored by the interface. After done is true, the RX2ES is located in the RX2DB register. Empty Buffer (001) - This function is used to empty the contents of the internal buffer through the RXV21 for use by the host processor. This data is in the buffer as the result of a previous FILL BUFFER or READ SECTOR command. 458 M8029 The programming protocol for this function is identical to that for the FILL BUFFER command. The RX2CS is loaded with the command to initiate the function. (This function will ignore bit 4 RX2CS, unit select.) RX2CS bit 8 (density) must be selected to allow the proper word count limit. When the command has been loaded, the done bit (RX2CS bit 5) goes false. When the TR bit is asserted, the RX2WC may be loaded into the RX2DB. When TR is again asserted the RX2BA may be loaded into the RX2DB. The RXV21 assembles one word of data at a time and transfers it directly to memory. Transfers occur until word count overflow, at which time the operation is complete and done goes true. If bit 6 RX2CS (interrupt enable) is set, an interrupt is initiated. After done is true, the RX2ES is located in the data buffer register. Write Sector (010) - This function is used to locate a desired sector on the diskette and fill it with the contents of the internal buffer. The initiation of the function clears RX2ES, TR, and done. When TR is asserted, the program must load the desired sector address into RX2DB, which will drop TR. When TR is again asserted, the program must load the desired track address into the RX2DB, which will drop TR. TR will remain unasserted while the RX02 attempts to locate the desired sector. The diskette density is determined at this time and is compared with the function density. If the densities do not agree, the operation is terminated; bit 4 RX2ES is set, RX2ES is moved to the RX2DB, error (bit 15 RX2CS) is set, done is asserted, and an interrupt is initiated, if bit 6 RX2CS (interrupt enable) is set. If the densities agree but the RX02 is unable to locate the desired sector within two diskette revolutions, the interface will abort the operation, move the contents of RX2ES to the RX2DB, set error (bit 15 RX2CS), assert done, and initiate an interrupt if bit 6 RX2CS (interrupt enable) is set. If the desired sector has been reached and the densities agree, the RXV21 will write the 128 10 or 6410 words stored in the internal buffer followed by a CRC character which is automatically calculated by the RX02. The RXV21 ends the function by asserting done and, if bit 6 RX2CS (interrupt enable) is set, initiating an interrupt. CAUTION The contents of the sector buffer are not valid data after a power loss has been detected by the RX02. However, write sector will be accepted as a valid instruction and the (random) contents of the buffer will be written, followed by a valid CRC. NOTE The contents of the sector buffer are not destroyed during a write sector operation. 459 M8029 Read Sector (011) - This function is used to locate the desired sector and transfer the contents of the data field to the internal buffer in the control. This function may also be used to retrieve rapidly (5 ms) the current status of the drive selected. The initiation of this function clears RX2ES, TR, and done. When TR is asserted the program must load the desired sector address into the RX2DB, which will drop TR. When TR is again asserted, the program must load the desired track address into the RX2DB, which will drop TR. TR and done will remain negated while the RX02 attempts to locate the desired sector. If the RX02 is unable to locate the desired sector within two diskette revolutions for any reason, ·the RXV21 /RX211 will abort the operation, set done and error (bit 15 RX2CS), move the contents of the RX2ES to the RX2DB, and if bit 6 RX2CS (interrupt enable) is set, initiate an interrupt. If the desired sector is successfully located, the control reads the data address mark and determines the density of the diskette. If the diskette (drive) density does not agree with the function density the operation is terminated and done and error (bit 15 RX2CS) are asserted. Bit 4 RX2ES is set (density error) and the RX2ES is moved to the RX2DB. If bit 6 RX2CS (interrupt enable) is set, an interrupt is initiated. If a legal data mark is successfully located, and the control and densities agree, the control will read data from the sector into the internal buffer. If a deleted data address mark was detected, the control will set bit 6 RX2ES (DD). As data enters the internal buffer, a CRC is computed based on the data field and the CRC bytes previously recorded. A nonzero residue indicates that a read error has occurred and the control sets bit 0 RX2ES (CRC error) and bit 15 RX2CS (error). The RXV21 ends the operation by asserting done and moving the contents of the RX2ES into the RX2DB. If bit 6 RX2CS is set, an interrupt is initiated. If the desired sector is successfully located, the densities agree and the data is transferred with no CRC error; done will be set and if bit 6 RX2CS (interrupt enable) is set, the RXV21 initiates an interrupt. Set Media Density (100) - This function causes the entire diskette to be reassigned to a new density. Bit 8 RX2CS (density) indicates the new density. The control reformats the diskette by writing new data address marks (double or single density) and zeroing all of the data fields on the diskette. 460 M8029 The function is initiated by loading the RX2CS with the command. Initiation of the function clears RX2ES and done. When TR is set, an ASCII "I" (111) must be loaded into the RX2DB to complete the protocol. This extra character is a safeguard against an error in loading the command. When the control recognizes this character it begins executing the command. The control starts at sector 1, track 0 and reads the header information, then starts a write operation. If the header information is damaged, the control will abort the operation. If the operation is successfully completed, done is set and if bit 6 RX2CS (interrupt enable) is set, an interrupt is initiated. CAUTION This operation takes about 15 seconds and should not be interrupted. If for any reason the operation is interrupted, an illegal diskette will be generated which may have data marks of both densities. This diskette should be completely reformatted. Maintenance Read Status (101) - This function is initiated by loading the RX2CS with the command. Done is cleared. The drive ready bit (bit 7 RX2ES) is updated by counting index pulses in the control. The drive density is updated by loading the head of the selected drive and reading the first data mark. The RX2ES is moved into the RX2DB. The RX2CS may be sampled when done (bit 5 RX2CS) is again asserted and if bit RX2CS (interrupt enable) is set, an interrupt will occur. This operation requires approximately 250 ms to complete. Write Sector with Deleted Data (110) - This operation is identical to function 010 (write sector) with the exception that a deleted data address mark is written preceding the data rather than the standard data address mark. The density bit associated with the function indicates whether a single- or double-density deleted data address mark will be written. Read Error Code (111) - The read error code function implies a read extended status. In addition to the specific error code, a dump of the control's internal scratch pad registers also occurs. This is the only way that the word count register can be retrieved. This function is used to retrieve specific information as well as drive status information depending upon detection of the general error bit. The transfer of the registers is a DMA transfer. The function is initiated by loading the RX2CS with the command; then done goes false. When TR is true, the RX2BA may be loaded into the RX2DB and TR goes false. The registers are assembled one word at a time and are then transferred directly to memory. 461 M8029 FOLLOWING IS THE REGISTER PROTOCOl. 15 WORD 1 WORD COUNT REGISTER DEFINITIVE ERROR CODE CURRENT TRACK ADDR DRV 1 CURRENT TRACK ADDR DRV 0 TARGET SECTOR TARGET TRACK BAD TRACK SOFT STATUS 15 WORD 2 15 WORD3 15 WORD 4 Definitive Error Codes 10 Drive 0 failed to see home on initialize. 20 Drive 1 failed to see home on initialize. 40 Tried to access a track greater than 76. 50 Home was found before desired track was reached. 70 Desired sector could not be found after 52 tries. 110 More than 40 /-LS and no SEP clock seen. 120 A preamble could not be found. 130 A preamble found but no 10 mark found within allowable time. 150 The track address of a good header does not compare with desired track. 160 Too many tries for lOAM. 170 Data was not found in allotted time. 200 CRC on reading the sector from the disk. 220 Failed maintenance wraparound check. 230 Word count overflow. 462 M8029 240 Density error. 250 Incorrect key word on SET DENSITY command. Register Protocol Word 1<7:0> Word 1< 15:8> Word 2<7:0> Word 2<15:8> Word 3<7:0> Word 3< 15:8> Word 4<7> Word 4<5> Word 4<6><4> Word 4<0> Word 4< 15:8> Definitive error codes Word count register Current track address of drive 0 Current track address of drive 1 Target track of current disk access Target sector of current disk access Unit select bit· Head load bit· Drive density bit of both drives· Density of READ ERROR REGISTER command· Track address of selected drive· * RX02 Power Fail or Initialize When the RX02 control senses a loss of power within the RX02, it will unload the head and abort all controller action. The RXAC L line is asserted to indicate to the RXV21 that subsystem power has gone. The RXV21 asserts done and error and sets the RXAC L bit in the RXZES. When the RX02 senses the return of power, it will remove done and begin a sequence to: 1. Move each drive head position mechanism to track 0 2. Clear any active error bits 3. Read sector 1 of track 1, on drive 0 4. Assert initialize done in the RXES. Upon completion of the power-up sequence, done is again asserted. There is no guarantee that information being written at the time of a power failure will be retrievable; however, all other information on the diskette will remain unaltered. For DMA interfaces, the controller status soft register is sent to the interface at the end of the command. The four status bits are included in an 8-bit word. Unit select = bit 7; density of drive 1 = bit 6; head load = bit 5; density of drive 0 = bit 4; density of READ ERROR REGISTER command = bit o. The track address of the selected drive-error is only meaningful on a code 150 error. The register contains the address of the cylinder that the head reached on a seek error. 463 M8043 M8043 DLV11-J SERIAL LINE UNIT Amp Bus Loads +5V + 12 V AC 1.0 0.25 Cables DC BC21B-XX BC20N-XX (Refer to DLV 11-KA) BC20M-XX Standard Addresses Configuration No. 1 Channel 0 Channel 1 Channel 2 Channel 3 RCSR RBUF XCSR XBUF 176500 176502 176504 176506 176510 176512 176514 176516 176520 176522 176524 176526 177560 177562 177564 177566 176500 176502 176504 176506 176510 176512 176514 176516 176520 176522 176524 176526 176530 176532 176534 176536 300 304 310 314 320 324 60 64 Configuration No. 2 RCSR RBUF XCSR XBUF Standard Vectors Configuration No. 1 Receiver Transmitter 464 M8043 Configuration No. 2 Receiver Transmitter 300 304 310 314 320 324 330 334 Diagnostic Programs Refer to Appendix A. NOTE This test requires that four H3270-A loopback plugs be inserted into the DLV11-J module in order for the diagnostic to run. Related Documentation DL V11-J User's Guide (EK-OLV1J-UG) Field Maintenance Print Set (MP00586) Microcomputer Interfaces Handbook (EB-20 175-20) 465 M8043 RCSR RECEIVER DONE (READONLYI NOTE: ONE OF FOUR CHANNELS SHOWN. FORMAT THE SAME FOR ALL CHANNELS. RECEIVER INTERRUPT ENABLE (READIWRITEI RCSR Registers Bit Assignments Word Bit Function RCSR 8-15 Not used. On read = O. 7 Receiver Done - Set when an entire character has been received and is ready for input to the processor. This bit is automatically cleared when RBUF is read, when INIT is asserted (on power-up or reset instruction), or when reader enable bit is set. Read only. If receiver interrupt enable (bit 6) is set, the setting of receiver done starts an interrupt sequence. 6 Receive Interrupt Enable - Set under program control when it is desired to allow a receiver interrupt sequence to occur when a character is ready for input to the processor (signified by receiver done being set). Cleared under program control or by INIT. Read/write. 1-5 Not used. On read = O. o Reader Enable - Setting this bit advances the paper tape reader on an L T -33 terminal one character at a time and the setting of this bit clears receiver done (bit 7). Write only. The DL V 11-KA 20 rnA current loop option is required for operation of this bit. 466 M8043 RBUF NOT USED RECEIVE OATA (7,8 BIT DATA IS RIGHT JUSTIFIED.I IF BIT UNUSED ~ 0 (REAO ONLYI (READ ONLYI NOTE: ONE OF FOUR CHANNELS SHOWN, FORMAT THE SAME FOR ALL CHANNELS. RBUF Register Bit Assignments Word Bit Function RBUF 15 Channel Error Status - Logical OR of bits 14, 13, and 12. Read only. 14 Overrun Error - When set, indicates that the reading of the previously received character was not completed (RCVR done not cleared) prior to receiving a new character. The first character is "lost." Read only; cleared by INIT being asserted. NOTE When back-to-back characters are received, one full character time is allowed from the instant when receiver done (bit 7) is set to the occurrence of an overrun error. 13 Framing Error - When set, indicates that the character read had no valid stop bit. This indicates that the currently received character and the next character are invalid. Read only; cleared by INIT. 12 Parity Error - When set, indicates that the parity received does not agree with the expected parity. This bit is always 0 if no-parity operation is configured for the channel. Read only. NOTE Error bits remain valid until the next character is received, at which time the error bits are updated. 8- 11 Not used. On read = O. 0- 7 Data Bits - Contains seven or eight data bits in a right-justified format. Bit 7 = 0 when seven data bits are enabled. Read only. 467 M8043 TRANSMIT READY (READ ONLY) TRANSMIT BREAK (READ/WRITE) TRANSMIT INTERRUPT ENABLE (READ/WRITE) NOTE ONE OF FOUR CHANNELS SHOWN FORMAT THE SAME FOR ALL CHANNELS. XCSR Registers Bit Assignments Word Bit Function XCSR 8-15 Not used. On read = O. 7 Transmit Ready - Set when XBUF is empty and can accept another character for transmission. It is also set by INIT during the power-up sequence or during a reset instruction. If transmitter interrupt enable (bit 6) is set, the setting of transmit ready will start an interrupt sequence. Read only. 6 Transmit Interrupt Enable - Set under program control when it is desired to generate a transmitter interrupt request (when transmitter is ready to accept a character for transmission). The bit is cleared under program control, during power-up sequence, or reset instruction. Read/write. o. 1-5 Not used. On read = o Transmit Break - Set or reset under program control. When set, a continuous space level is transmitted. However, transmit done and transmit interrupt enable can still operate, allowing software timing of break. When not set, normal character transmission can occur. Read/write; cleared by INIT being asserted. 468 M8043 15 14 13 12 11 10 09 08 RCSR INOT USED) RECEIVER DONE IREAD ONLY) RECEIVER INTERRUPT ENABLE IREADIWRITE) 11 10 09 07 OB 06 05 04 03 02 01 00 RBUF . NOT USED 15 14 13 12 11 10 09 RECEIVE DATA 17.8 BIT DATA IS RIGHT JUSTIFIED.) IF BIT UNUSED = 0 IREAD ONLY) OB 05 04 03 02 01 XCSR INOT USED) INOT USED) TRANSMIT BREAK IREADIWRITE) TRANSMIT INTERRUPT ENABLE IREADIWRITE) XBUF 15 14 13 12 11 10 09 08 0 0 0 0 0 0 0 : I I : : : : : 07 06 05 04 03 02 01 00 0 INOT USED) TRANSMIT DATA 17. B BIT DATA IS RIGHT JUSTIFIED.) IWRITE ONL Y) ON READ = 0 NOTE ONE OF FOUR CHANNELS SHOWN. FORMAT THE SAME FOR ALL CHANNELS. DL V 11-J SLU Register Formats XBUF Register Bit Assignments XBUF 8-15 Not used. On read = O. 0-7 Data bits - Contains seven or eight right-justified data bits. Loaded under program control for serial transmission. Write only. 469 M8043 Jumper Configurations 2 X3 CHOAND{ CHl EIA SELECTION R R 3 MOe_ NOe _ e Mle_ Nle_ e Rl0 CHO ....c:::J-e CHO{ E f'i"l De_ S ri""I { De_ CHl w ::::i Z ~Ul «Il: ~.~ ::a:« ::a:1l: 0« uo.. pe_ CHl E'" ~[L Jl 1~~2:~ 2::t.: V 3~N }:-:!!":ATE x2 e_ e -_ _ eM2 eN2 eM3 eN3 } CH2 AND CH3 EIA SELECTION SELECTION ALWAYS IN LUT M CHl TERM RESISTOR CHO TERM RESISTOR CH2 TERM RESISTOR '-----CH3 TERM RESISTOR I S ... Pe_ CH2 Ef'i"l CH2{ De_ sf'i"l Pe_ CH3 Ef'i"l De_ S ...... pe_ o "X ADDRESS AND A5"-'1 A9 ...... A12e Al0e_ Alle_ Ase_ C2e Cle V5...... o1X VECTOR JUMPERS ~{A6_ A7. e e_ V6V7- BX H '--v-' BREAK SELECTION (CHANNEL 3) DLV 11-J Component and Jumper Factory Configuration Summary 470 M8043 Address Selection ~ j j j j j j j j ~~YTIE ~SELECT~ ~~~:~~DR~~SS ,~--e-~~= ~~~~ ! rI SELECTED III BANK IDEVICEI FACTORY SELECT POINTER . -. 1 I =176500 10=XCSR 11 = XBUF ---.J 3 WIRE WRAP POSTS IX. 1,01 ARE PROVIDED FOR EACH BIT. 2 WIRE WRAP POSTS ARE PROVIDED FOR EACH BIT. JUMPER X TO 1 = 1 JUMPE R X TO 0 = 0 NOTE: RANGE 16ooooB-1777708 NON EXTENDED ADDRESS 7600008 -777770 8 EXTENDED ADDRESS JUMPER IN = 1 JUMPER OUT = 0 00 = CHANNEL 0 01 = CHANNEL 1 10 = CHANNEL 2 11 = CHANNEL 3 Device Register Address Format It is possible to independently configure the last four addresses (channel 3) to the LSI-11 console device (addresses 177560-177566) when certain base addresses and console select jumpers· are installed. In this configuration, the preceding addresses (channels 0, 1, and 2) are not affected; they are normal offsets of the configured base device address as shown in the following table. General Device Register Address Assignments (Without Console Selected) Address Device Register Module Base Address (BA) BA + 2 BA + 4 BA + 6 BA + 10 BA + 12 BA + 14 BA + 16 BA + 20 BA + 22 BA + 24 BA + 26 BA + 30 BA + 32 BA + 34 BA + 36 Channel 0 RCSR Channel 0 RBUF Channel 0 XCSR Channel 0 XBUF Channel 1 RCSR Channel 1 RBUF Channel 1 XCSR Channel 1 XBUF Channel 2 RCSR Channel 2 RBUF Channel 2 XCSR Channel 2 XBUF Channel 3 RCSR Channel 3 RBUF Channel 3 XCSR Channel 3 XBUF * Console select jumpers C 1 and C2 installed select channel 3 as console device. 471 M8043 General Device Register Address Assignments (General Configuration With Console Selected) Address Device Register Module Base Address (BA) BA + 2 BA 4 BA + 6 BA + 10 BA 12 BA 14 BA + 16 BA 20 BA 22 BA + 24 BA + 26 177560 177562 177564 177566 Channel 0 RCSR Channel 0 RBUF Channel 0 XCSR Channel 0 XBUF Channel 1 RCSR Channel 1 RBUF Channel 1 XCSR Channel 1 XBUF Channel 2 RCSR Channel 2 RBUF Channel 2 XCSR Channel 2 XBUF Channel 3 * RCSR Channel 3 RBUF Channel 3 XCSR Channel 3 XBUF + + + + + * Channel 3 is enabled as a console device. 472 M8043 Specific Device Register Address Assignments (DLV11-J Configured With BA = 176500 and BV = 300 Without Console Selected) Address Register Vector 176500 176502 RCSR RBUF 300 176504 176506 XCSR XBUF 304 176510 176512 RCSR RBUF 310 176514 176516 XCSR XBUF 314 176520 176522 RCSR RBUF 320 176524 176526 XCSR XBUF 324 176530 176532 RCSR RBUF 330 176534 176536 XCSR XBUF 334 177560 177562 RCSR RBUF 60 177564 177566 XCSR XBUF 64 Channel Channel 0 Channel 1 Channel 2 Channel 3 Channel 3 Console Device NOTE All addresses are in octal notation. 473 M8043 Vector Selection When channel 3 is configured as the console device interface using console select jumpers C 1 and C2, the interrupt vectors of the channel become 60 and 64. This is true regardless of the configured base vector of the module. It should be noted that the preceding channels (0, 1, and 2) are not affected and their vectors are normal offsets of the base vector configured, as shown in the following table. General Vector Assignments (Without Console Selected) Vector Offsets Interrupt Vector Module Base Vector (BV) BA + 4 BA + 10 BA + 14 BA + 20 BA + 24 BA + 30 BA + 34 Channel 0 Receiver Channel 0 Transmitter Channel 1 Receiver Channel 1 Transmitter Channel 2 Receiver Channel 2 Transmitter Channel 3 Receiver Channel 3 Transmitter General Vector Assignments (With Console Selected) Vector Offsets Interrupt Vector Module Base Vector (BV) BA + 4 BA + 10 BA + 14 BA + 20 BA + 24 60 64 Channel 0 Receiver Channel 0 Transmitter Channel 1 Receiver Channel 1 Transmitter Channel 2 Receiver Channel 2 Transmitter Channel 3 Receiver· Channel 3 Transmitter· • Console selected 474 M8043 Specific Vector Assignments (DLV11-J Configured With BV = 300 Without Console Selected) Octal Vector Interrupt Vector 300 304 310 314 320 324 330 334 Channel 0 Receiver Channel 0 Transmitter Channel 1 Receiver Channel 1 Transmitter Channel 2 Receiver Channel 2 Transmitter Channel 3 Receiver Channel 3 Transmitter Specific Vector Assignments (F actory-Configured With BV = 300 With Console Selected) Octal Vector Interrupt Vector 300 304 310 314 320 324 60 Channel 0 Receiver Channel 0 Transmitter Channel 1 Receiver Channel 1 Transmitter Channel 2 Receiver Channel 2 Transmitter Channel 3 Receiver· Channel 3 Transmitter· 64 • Console selected 475 M8043 17 o '--y----J~ FACTORY-CONFIGURED BASE INTERRUPT VECTOR ADDRESS = 300 TWOWIREWRAP POSTS ARE PROVIDED FOR EACH BIT. JUMPER IN = 1 JUMPER OUT = 0 r. tJ CHANNEL 0 = RECEIVER REQUESTING INTERRUPT INTERRUPT 4 = TRANSMITTER (0-3) INTERRUPT 1 1 '-----y--l THREE WIRE WRAP POSTS ARE PROVIDED FOR BIT V5. JUMPER X TO 1 = 1 JUMPER X TO 0 = 0 WITH CONSOLE NO JUMPER = 0 WITHOUT CONSOLE OTE: RANGE 0-377B (040B NOT ALLOWED IN CONSOLE MODE) Console device jumpers are used to select channels as the console interface. These jumpers (C 1 and C2) will affect address and vector selection. Summary of Console Selection Jumper Configurations Label Console Selected Console Not Selected C1 Install jumper from wirewrap pins X to 1. Install jumper from wirewrap pins X to o. C2 Install jumper from wirewrap pins X to 1. Install jumper from wirewrap pins X to O. Configuring Channel Word Formats Each DL V 11-J SLU channel can be individually configured for number of data bits (7 or 8); even, odd, or not parity; 1 or 2 stop bits, and baud rate (described in the next section). A summary of possible character format jumper configurations is shown below. 476 M8043 Summary of Character Format Jumper Configurations UART Label Parameter X toO X to 1 Comments LSB is transmitted first D Number of data bits 7 bits 8 bits S Number of stop bits 1 bit 2 bits P Parity inhibit Parity generation and detection enabled Parity generation and detection disabled E Even parity enabled Odd parity enabled Even parity enabled Requires' P jumper connected from X to 0 NOTE E jumper must be connected to either 0 or 1, even if the parity bit is disabled. Two stop bits are generally used only with Teletype terminals. CAUTION To prevent hardware damage within the channel, the E jumper must ALWAYS be installed. This is true regardless of the configuration of the P (parity) jumper. Baud Rate Selection NOTE A 110 baud rate clock generator circuit is contained on the optional DLV11-KA 20 mA option. When 110 baud operation is desired, do not connect the baud rate jumper on the DLV11-J module for that particular channel. The 110 baud rate will be supplied by the DLV11-KA option through the interface connector. 477 M8043 Configure baud rates (except 110 baud) by connecting a jumper from an appropriate baud rate generator output wirewrap pin to the baud rate clock input pin (labeled 0-3); one jumper is required for each channel. Baud rate generator outputs are identified below. Baud Rate Generator Outputs Wirewrap Pin Label Baud Rate (Blt/S) U 150 300 600 1200 2400 4800 9600 19200 38400 T V W y L N K Z NOTE If more than one channel requires the same baud rate, the wirewrap jumpers may be daisy-chained. Channel 3 Break Response Channel 3 (normally used as the console device) can respond to a break condition on the receive line such as when an operator presses the BREAK key on the associated terminal. The BREAK key transmits a continuous space signal which is detected by the DL V 11-J circuits as a framing error. If no operation is desired, do not connect jumpers to the B, X, and H wirewrap pins. Channel 3 Break Operation Jumper Summary Break Response Operation Jumper Connection Boot Install jumper between wirewrap pins X and B. Halt Install jumper between wirewrap pins X and H. No response No jumper installed. 478 M8043 Summary of Serial Channel Signal Level Compatibility Configurations Serial Channel Signal Level Serial Channel Signal Level Modifiers 20 rnA Current Loop (Required DLV11-KA Option) EIA RS-422 EIA RS-232C and RS-423 MO-3 jumpers Connect wirewrap pins X and 2. Connect wirewrap pins X and 3. Connect wirewrap pins X and 3. NO-3 jumpers Connect wirewrap pins X and 2. Connect wirewrap pins X and 3. Connect wirewrap pins X and R for program-controlled paper tape reader functionality. Termination resistor (one per channel) Install a 100 Q, 1/4 W, non-wirewound, fusible resistor. No resistor installed. No resistor installed. Wave shaping resistor, one per channel pair (channel pairs 0 and 1; 2 and 3). Not required. Install resistor (see next table). 1/4 W non-wirewound. Install 22 K Q non-wirewound resistor. 479 M8043 EIA RS-422 - To configure an SLU channel for EIA RS-422 signal levels, connect the M(MO-M3) and N(NO-N3) jumper wirewrap pin X of the desired channel to the respective wirewrap pin 2. Install (solder) a 100 ohm, 1/4 W fusible resistor (non-wirewound) into the termination resistor mounting pads for the channel being configured. The resistor must be removed for any configuration other than EIA RS-422. EIA RS-423 and RS-232C - To configure an SLU channel to be compatible with both the EIA RS-423 and RS-232C (which on the DL V 11-J are met simultaneously), connect each M(MO-M3) and N(NO-N3) jumper X wirewrap pin of the desired channel to the respective wirewrap pin 3. Slew Rates - The signal rise and fall time may be controlled on EIA RS-423 and RS-232C SLU channel configurations by installing (soldering) an appropriate value of non-wirewound, 1/4 W resistor into the wave-shaping resistor pads provided (R 10 and/or R23). An appropriate resistor value can be selected by referring to the following table. The value of resistor R 10 determines the slew rate of both channels 0 and 1 which are simultaneously set to the same value. Similarly, R23 controls the slew rate of both channels 2 and 3. EIA RS-423 and RS-232C Wave-Shaping Resistor Values Baud Rate Wave-Shaping Resistor 38.4K 19.2K 9.6K 4.8K 2.4K 1.2K 600.0 300.0 150.0 110.0 22 kQ 51 kQ 120 kQ 200 kQ 430 kQ 820 kQ 1 MQ 1 MQ 1 MQ See Note. NOTE Determined by other channel of the two-channel pair. 480 M8043 20 rnA Current Loop - To configure an SLU channel for 20 rnA current loop operation, connect the M(MO-M3) jumper pin X to pin 3 for the desired channel. If the 20 rnA terminal contains a paper-tape reader that can be program-controlled (such as a DEC-modified L T-33 Teletype or Teletype ASR-33 with L T22-MD modification kit), connect wirewrap jumper N(NO-N3) pin X to the respective pin R. When the DL V 11-KA 20 rnA current loop option is connected to the channel interface connector, operating power for the option circuits is supplied by the DL V 11-J. To configure a channel for 110 baud operation, enable the 110 baud rate clock on the DL V 11-KA option and remove the baud rate selector jumper for the channel on the DL V 11-J module. The clock needed by the DL V 11-J is automatically supplied through the serial line connector cable. 481 M8043 DLV11-J TO MODEM OR ACOUSTIC COUPLER _gl tDLV11 J f f i - '50FT ~ 'm J BC20M-50~~~~~~J..g DLV11-J) DLV11-J TO LOCAL TERMINAL 14FT ~ -~-9FT~l!l (NOTE 2) NOTES: 1. MODEM USED IS A "MANUAL TYPE" SUCH AS BELL 103A WITH B04B. 2. DEC EIA RS·232C TERMINALS (VT52, LA36, LS120, ETC.) COME EQUIPPED WITH A 9 FT CABLE. NON-DEC EIA RS·232C TERMINALS ARE CONNECTED SIMILARLY EXCEPT 9 FT OF LENGTH MUST BE DEDUCTED FROM THE TOTAL CABLE LENGTH. DL V 11-J Cabling Summary 482 M8043 2 X 5 PIN AMP NO 87133-5 RECEPTACLE :1~ 8 10 STANDARD EIA RS-232C 25 PIN CONNECTOR ~-------------5FT------------~ (SEE NOTE) 7 9 L -_ _ _-L..-' NOTE: CABLE RETENTION IN DLV11-J CONNECTOR IS PROVIDED BY" LOCKING PINS". PULL BACK ON THE RECEPTACLE TO SLIDE OUT OF DLV11-J CONNECTOR. HOWEVER, IF THE CABLE IS PULLED, THE "LOCKING PINS" HOLD THE RECEPTACLE FIRMLY IN THE DLV11-J CONNECTOR. o GROUND SHIELD (ATTACH TO CHASSIS) INDEX KEY ( 5 ( - - , CLEAR TO SEND (CB) I I 4(--...1 REQUEST TO SEND (CA) RCV DATA - >7 6(--, DATA SET READY (CC) I I ~10>-l~-I---------------"";';;;"-'-I""'1\,I-<20(--...1 DATA TERMINAL READY (CD) +12 VDC RCV DATA + > 8 >--i!--+-----------------t--_t__( 3 < R ECE I V ED DATA (BB) XMIT DATA + > 3 >-I~-I---------------I-__I__< 2< TRANSMITTED DATA (BA) GAD> 2 >-1--1-------------11--+-< 7 < SI GNA L G ROUN D (AB) ,)J---------II--+-< 1 < DLVll-J MODULE CONNECTOR CABLE EIA RS-232C CONNECTOR PROTECTIVE GROUND (AA) MODEM BC21B-05 Peripheral Device Cable 483 M8043 BC21B-05 L-__________~~4r-----------5FT------------~--------~ NOHS: CD MODEM OR ACOUSTIC COUPLER. MODEMS SHOWN ARE "MANUAL" MODEMS SUCH AS BELL 103A DATA SETS WITH B04IB AUXILIARY SET. o =2NECTORS X 5 PIN AMP NO B7133-5 CON- ~ = EIA RS-232C 25 PIN MALE CONNECTORS ~ = EIA RS-232C 25 PIN FEMALE CONNECTORS DL V 11-J to Modem or Acoustic Coupler 484 M8043 TERMINAL .. BC20N-05 "NULL MODEM" CABLE ~4r-------9FT------~~1 TERMINAL NOTES TERMINALS SHOWN ARE DEC EIA RS-232C TERMINALS (SUCH AS VT52, LA36, LS120, ETC.) DEC TERMINALS ARE CONSTRUCTED WITH 9 FOOT CABLES, WHEN USING NON-DEC EIA RS-232C TERMINALS DEDUCT 9 FEET FROM THE TOTAL CABLE LENGTH. [6J = 2 X 5 PIN AMP NO 87133-5 CONNEC· TORS ~= EIA RS-232C 25 PIN MALE CONNECTORS ~= EIA RS-232C 25 PIN FEMALE CONNECTORS MR-1282 Local Terminal Cabling 485 M8043 CONNECT TO CHASSIS GROUND CONNECT TO CHASSIS GROUND 10 10 ~-------------50FT------------~ 2 X 5 PIN AMP NO 87133·5 RECEPTACLE INDEX KEY INDEX KEY NOTE BOTH CONNECTORS HAVE THE SAME CABLE RETENTION MECHANISM. CABLE RETEN· TION IS PROVIDED 8Y "LOCKING PINS". PULL ON RECEPTACLE TO RELEASE. BC20M-50 DL V 11-J to DL V 11-J Cable BCOlV-25 OR BC05C-25 o = 2 x 5 PIN AMP NO 87133·5 CONNECTORS ~ = EIA RS·232C 25 PIN MALE CONNECTORS ~ = EIA RS·232C 25 PIN FEMALE CONNECTORS ~ = 40 PIN BERG MALE CONNECTORS 8 = 40 PIN BERG FEMALE CONNECTORS DL V 11-J to SLU Module Cabling 486 M8044/45 M8044/45 MSV11-D, -E MOS READ/WRITE MEMORY Model Memory Capacity Module Parity Bits MSV11-DA MSV11-DB MSV11"DC MSV11-DD MSV11-ED 4K by 16 bits 8K by 16 bits 16K by 16 bits 32K by 16 bits 32K by 18 bits M8044-AA M8044-BA M8044-CA M8044-DA M8045-DA No No No No Yes Amps Bus loads Cables AC 2 None +5 2.0 + 12 0.41 DC Standard Addresses Module is shipped configured to start at bank O. Vectors None Diagnostic Programs Refer to Appendix A. NOTE DEC diagnostic will not check parity. Related Documentation MSVll-0, -£ User's Manual (EK-MSV1D-OP) Field Maintenance Print Set (MP00259) Microcomputer Processor Handbook (EB-18451-20) 487 M8044/45 Address Selection The MSV 11-D or MSV 11-E address can start at any 4K bank boundary. The address configured is the starting address for the contiguous portion of memory (4K, 8K, 16K, or 32K) contained on the module. SI ADDRESS SWITCHES {IJ~~=~ MEMORY ( SIZE 6. J 5" 7e1. SEE NOTE 1 S1-1 S1-4 ••• ••• S1-5 12 14 10 PARITY/NO PARITY OPERATION 17 15 16 SEE NOTE 2 NOTES: 1. JUMPER 1 TO 2 = 30K OPTION (MINC) 1 TO 3 FOR NO 30K OPTION 2. JUMPER 5 TO 7 FOR MSV11-D OR 5 TO 6 FOR MSV11-E MSV 11-D, MSV 11-E Switch and Jumpers M8044,45 Set the switches to the desired starting address as listed in the table. Note that the module is designated to accommodate a 128K system addressing capability. However, the present addressing capability of the LSI-11 system, including all PDP-11 /03, PDP-11 V03 and PDP-11 T03 systems, is 32K. PDP-11/23 systems, however, can address within the full 128K word range. By PDP-11 convention, the upper 4K address space is normally reserved for peripheral device and register addresses. Thus, with the present LSI-11 maximum addressing capability of 32K, bank 7 (address 160000-177777) normally should not be used for system memory. 488 M8044/45 Factory-configured modules will not respond to bank 7 addresses. In special applications that permit the use of the lower 2K portion of bank 7 for system memory (i.e., MINC), enable the lower 2K portion of bank 7 by removing the jumper from wirewrap pins 1 and 3 and connecting a new jumper from 1 to 2. NOTE If 30K option is enabled, some diagnostics may not run. Battery Backup Power MSV 11-0 and MSV 11-E modules are factory configured with power jumpers installed for normal system power only. If the system uses a battery backup power source, remove jumpers W2 and W3. Install new jumpers W4 and W5. (Two jumpers are removed and two new jumpers are installed.) Parity One jumper is factory installed for nonparity (MSV 11-0) or parity (MSV 11E) operation, depending on the model. 00 not reconfigure this jumper. Standard jumper configurations are listed below. • All MSV 11-0 models: jumper installed from pin 7 to pin 5. • All MSV 11-E models: jumper installed from pin 6 to pin 5. NOTE This memory parity feature is not supported by DEC diagnostics or CPUs. Memory Size Two jumpers are factory installed to configure addressing logic for memory size (number and type of memory-integrated circuits). 00 not reconfigure these jumpers. Standard jumper configurations are listed below. Models Jumpers (Two Installed) Memory· Select Pins Memory Range Pins MSV11-0A MSV11-0B MSV11-0C MSV 11-00, EO From 17 to 14 From 12 to 14 From 16 to 14 From 10 to 14 489 From 17 to 15 From 17 to 15 From 16 to 15 From 16 to 15 MSV11-D, MSV11-E Addressing Summary Switch Settings ~ co o MSV11-DA, MSV11-EA 4K Memory Bank(s) Selected MSV11-DB, MSV11-DC, MSV11-EB MSV11-EC MSV11-DD, MSV11-ED N F N F N 0 1 2 3 4 0-1 1-2 2-3 3-4 4-5 0-3 1-4 2-5 3-6 4-7 0-7 1-10 2-11 3-12 4-13 N F F N N F N F N F 5 6 7 10 11 5-6 6-7 7-10 10-11 11-12 5-10 6-11 7-12 10-13 11-14 5-14 6-15 7-16 10-17 11-20 N N F F F F F N N F N F N F N 12 13 14 15 16 12-13 13-14 14-15 15-16 16-17 12-15 13-16 14-17 15-20 16-21 12-21 13-22 14-23 15-24 16-25 F N N N N F N N F F F N F N F 17 20 21 22 23 17-20 20-21 21-22 22-23 23-24 17-22 20-23 21-24 22-25 23-26 17-26 20-27 21-30 22-31 23-32 Starting Address S1-1 S1-2 S1-3 S1-4 S1-5 0 20000 40000 60000 100000 N N N N N N N N N N N N N N F N N F F N 120000 140000 160000 200000 220000 N N N N N N N N F F F F F N N 240000 260000 300000 320000 340000 N N N N N F F F F F 360000 400000 420000 440000 460000 N F F F F F N N N N MSV11-D, MSV11-E Addressing Summary (Cont) MSV11-DA, MSV11-EA 4K Memory Bank(s) Selected MSV11-DB, MSV11-DC, MSV11-EB MSV11-EC MSV11-DD, MSV11-ED N F N F N 24 25 26 27 30 24-25 25-26 26-27 27-30 30-31 24-27 25-30 26-31 27-32 24-33 25-34 26-35 27-36 30-37 N F F N N F N F N F 31 32 33 34 35 31-32 32-33 33-34 34-35 35-36 31-34 32-35 33-36 34-37 X X X X X X F F N F 36 37 36-37 X X X X Switch Settings Starting Address S1-1 S1-2 S1-3 S1-4 S1-5 500000 520000 540000 560000 600000 F F F F F N N N N F F F F F N N N F F N 620000 640000 660000 700000 720000 F F F F F F F F F F N N N F F 740000 760000 F F F F F F NOTES 1. Switch settings: N = ON F = OFF 2. In unmapped systems, bank 7 cannot be selected as factory configured; however, the user can enable the lower 2K portion of bank 7. 3. X = Do not use. X 30~33 M8047 M8047 MXV11-AA/AC MULTIFUNCTION MODULE The MXV 11 is a multifunction option module used for the LSI-11, LSI-11 /2, or LSI-11 /23 systems. It contains read/write memory provisions for readonly memory, two asynchronous serial line interfaces and a 60 Hz clock derived from a crystal oscillator. Detailed technical information is beyond the scope of this document. Additional information can be found in the Microcomputer Processor Handbook, EB-18451-20. Model Designations • MXV11-AA contains 8K bytes of random access memory . • MXV 11-AC contains 32K bytes of random access memory. + Both models have two 24-pin sockets that provide for 5 V read-only memories in which 1K X 8, 2K X 8, or 4K X 8 ROMs may be used. These sockets may also be used for 256 words of bootstrap code. Amps +5 + 12 1.2 0.1 Bus Loads Cables AC 2 BC20M-XX BC20N-XX (Refer to DL V 11-KA) BC21B-XX DC 2 Standard Addresses RAM - Starts on any 8K boundary below 64KB. SLU Channel 0 176500 Channel 1 177560 Standard Vectors SLU 300 60 493 M8047 Diagnostic Programs Refer to Appendix A. Requires wraparound connectors to completely exercise SLU. Options MXV 11-A2 Boot ROMs for RX02, RXO 1, or TU58 PNs: 23-03901-00, 23-04001-00 ROMs Power: +5 V ± 5% Pins: 24-Pin DIP Access Time: Up to 450 nanoseconds Array Size: 1K X 8, 2K X 8, or 4K X 8 bits Type: Typical PROM types: UV PROMs Chip Array Size Memory Size Intel 2758 Intel 2716 Intel 2732 Mostek MK27 16 T.I. TMS 2516 T.I. TMS 2532 1K X 8 bits 2K X 8 bits 4K X 8 bits 2K X 8 bits 2K X 8 bits 4K X 8 bits 1K words 2K words 4K words 2K words 2K words 4K words 1K X 8 bits 1K X 8 bits 1K X 8 bits 2K X 8 bits 1K words 1K words 1K words 2K words Bipolar PROMs Intel 3628 Signetics 82S 2708 Signetics 82S 181 Signetics 82S 191 494 M8047 CHANNELl J66 J65 .A..A. J68.A. J67.A. /!t\~ J64 J63 J62 J6l J60 J59 .A.J58 .A. J57 .A. J56 .A.J55 .A.J54 .A.J53 .A.J52 .A.J5l .A. J50 .A. J49 .A.J48 .A.J47 .A.J46 .A.J45 .A. J44 .A. J43 .A. J42 .A. J41 .A.J40 .A. J39 .A.J38 .A.J37 .A. J36 .A.J35 .A.J34 .A.J33 .A.J32 .A.J3l .A.J30 .A. J29 .A. J28 .A.J27 .A. J26 .A.J25 .A.J24 .A.J23 .A. J22 .A. J2l .A.J20 .A.J19 .A.J18 .A.J17 .A.J16 .A.J15 .A.J14 .A.J13 .A. J12 .A.Jll .A.Jl0 .A.J9 .A.J8 J7 .A. .A..A. .A..A. J6 J5 J4 J3 A MXV 11-A Jumper Locations 495 M8047 MXV11-A Jumper Functions Pin Function Option J3 Clock L. Open collector output of the clock. Connected to pin AF 1 (SSpare 2). Wirewrap to J4 to implement the clock option. 60 Hz J4 BEVNT L. Event interrupt (pin BR 1) used for the clock option. 60Hz J5 BOCOK H. OCOK (pin BA 1) when high allows the processor to operate; when low initializes the system. Connected to J6 to use the boot option. Boot J6 Framing Error. Open collector output of framing error from serial line one. Connected to pin AE 1 (SSpare 1). Wirewrap to J5 to implement the boot option. Reset by bus initialize or reception of a valid character. Break J7 BHAL T L. Halt (pin AP 1) when low will stop program execution and cause the processor to enter OOT microcode. Connected to J6 to implement the halt option. Halt J8 GNO. A ground signal that can be used to disable ROM by wirewrapping to J21 or to disable a serial line by wirewrapping to an address input pin (J23 or J24 for serial line 0; or J25, J26, J27, or J28 for serial line 1). ROM J9 A 13 L. Address bit 13 asserted low. Wirewrap to J 11 to select bank 1 with the ROM address decoder. ROM J10 A 13 H. Address bit 13 asserted high. Wirewrap to J 11 to select bank 0 with the ROM address decoder. ROM J 11 A 13 M. Address bit 13 input to the ROM address decoder. See J9 and J 1O. Used only if J20 is wirewrapped to J21. ROM J12 A03 H. Address bit 03 asserted high. Wirewrapped to the serial line address decoders (J23 or J24 for serial line 0, J25, J26, J27 or J28 for serial line 1) when address bit 03 is to be decoded as a 1. SLU 496 M8047 MXV11-A Jumper Functions (Cont) Pin Function Option J13 A04 H. Address bit 04 asserted high. Wirewrapped to the serial line address decoders when address bit 04 is to be decoded as a 1. SLU J14 A05 H. Address bit 05 asserted high. Wirewrapped to the serial line one address decoder when address bit 05 is to be decoded as a 1. SLU J15 A09 H. Address bit 9 asserted high. Wirewrapped to the serial line one address decoder when address bit 09 is to be decoded as a 1. SLU J16 A09 L. Address bit 09 asserted low. Wirewrapped to the serial line one address decoder when address address bit 09 is to be decoded as a O. SLU J17 A05 L. Address bit 05 asserted low. Wirewrapped to the serial line one address decoder when address bit 05 is to be decoded as a O. SLU J18 A04 L. Address bit 04 asserted low. Wirewrapped to the serial line address decoders when address bit 04 is to be decoded as a O. SLU J19 A03 L. Address bit 03 asserted low. Wirewrapped to the serial line address decoders when address bit 03 is to be decoded as a O. SLU J20 ROM address. Output of the ROM address decoder. Connected to J21 when ROM is to be used in bank 0 or bank 1. ROM J21 ROM select. ROM address selection enable asserted high. Wirewrapped to J8 (GND) to disable ROM, to J20 for bank 0 or bank 1, or to J22 for bootstrap. ROM J22 Boot address. Output of the bootstrap address decoder. Connected to J21 when ROM is to be used in the bootstrap range from 173000-173776 (773000773776 for LSI-11 /23). BOOT J23 Serial line 0 address decoder input asserted high. May be wirewrapped to A03 H (J 12), A03 L (J 19), A04 H (J13), or A04 L (J18). SLU 497 M8047 MXV11-A Jumper Functions (Cont) Pin Function Option J24 Serial line 0 address decoder input asserted high. May be wirewrapped to A03 or A04, whichever bit is not wired to J23. May be wirewrapped to GND (J8) to disable serial line o. SLU J2SJ28 Serial line 1 address decoder input asserted high. Four address decoder inputs to be connected to address bits A03, A04, AOS, and A09. Whether the high or low assertion state of a bit is wirewrapped to an input determines if that bit is decoded as a 1 or a o. See J 12 through J 19. May be wirewrapped to GND (J8) to disable serial line 1. SLU J29 ROM address bit 09 input. Wirewrapped to A09 H (J 15) for normal ROM addressing and also for the MXV 11-A2 option when the TUS8 bootstrap is desired. Wirewrapped to A09 L (J 16) for the MXV 11-A2 option when the disk bootstrap is desired. ROM J30J32 RAM starting address selection. These pins are wirewrapped to J33 (logic 0) or J34 (logic 1) to select the RAM starting address (see the following). RAM J32 J31 J30 Bank Starting Address 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 2 3 4 5 6 7 000000 020000 040000 060000 100000 120000 140000 160000 J33 GND. Logic 0 level signal used for selecting the RAM starting address and for enabling some ROM IGs in the ROM sockets. RAM, ROM J34 +3 V. Logic 1 level signal used for selecting the RAM starting address and for enabling some ROM IGs in the ROM sockets. RAM, ROM 498 M8047 MXV11-A Jumper Functions (Cont) Pin Function Option J35 A 12 H. Address bit 12 asserted high. Used for addressing 4K X 8 bit ROMs. Wirewrapping to J37, J38 or J39, depending on the ROM used. ROM J36 A 11 H. Address bit 11 asserted high. Used for addressing 2K X 8 and 4K X 8 bit ROMs. Wirewrapping to J37, J38, or J39, depending on the ROM. ROM J37 Pin 18 on both ROM sockets. Used for addressing or enabling ROM. Wirewrapped to J33 for ground, to J34 for + 13 V, to J35 for A 12, or to J36 for A 11. ROM J38 Pin 19 on both ROM sockets. Used for addressing or enabling ROM. Wirewrapped to J33 for ground, to J34 for +3 V, to J35 for A 12, or to J36 for A 11. ROM J39 Pin 21 on both ROM sockets. Used for addressing or enabling ROM. Wirewrapped to J33 for ground, to J34 for + 3 V, to J35 for A 12 to J36 for A 11 or to J40 for +5 V. ROM J40 + 5 V. Used to power some ROMs on pin 21. ROM J41 Used for 150 baud. Wirewrapped to J45 for serial line 0, to J46 for serial line 1. (See following table.) SLU J42 Used for 1200 baud. SLU J43 Used for 300 baud. SLU J44 Used for 2400 baud. SLU J45 Clock O. The clock input for serial line 0 transmit and receive, 16 times the baud rate. Wirewrapped to either J41, J42, J43, J44, J47, J48, J49, or J50. SLU J46 Clock 1. The clock input for serial line 1 transmit and receive, 16 times the baud rate. Wirewrapped to either J41, J42, J43, J44, J47, J48, J49, or J50. SLU J47 Used for 4800 baud. SLU J48 Used for 9600 baud. SLU 499 M8047 MXV11-A Jumper Functions (Cont) Pin Function Option J49 Used for 19.2K baud. SLU J50 Used for 38.4K baud. SLU J51 Vector o. Vector enable for channel o. Used to drive vector bits that pass the test: logic 1 for channel 0, and logic 0 for channel 1. Wirewrapped to J53 for bit 03, to J54 for bit 04, to J55 for bit 05, to J56 for bits 06 and 07. SLU J52 Vector 1. Vector enable for channel 1. Used to drive vector bits that pass the test: logic 0 for channel 0 and logic 1 for channel 1. Wirewrapped to J53 for bit 03, to J54 for bit 04, to J55 for bit 05, to J56 for bits 06 and 07. SLU J53 Vector bit 03. Selects how bit 03 is to be driven for interrupt vectors. Wirewrapped to J51 if a logic 1 for channel 0 and a logic 0 for channel 1; to J52 if a logic 0 for channel 0 and a logic 1 for channel 1; to J57 if a logic 0 for both channel 0 and channel 1; or to J58 if a logic 1 for both channel 0 and channel 1. SLU J54 Vector bit 04. Selects how bit 04 is to be driven for interrupt vectors. Wirewrapped the same as J53. SLU J55 Vector bit 05. Selects how bit 05 is to be driven for interrupt vectors. Wirewrapped the same as J53. SLU J56 Vector bits 06 and 07. Selects how bits 06 and 07 are to be driven for interrupt vectors. Wirewrapped the same as J53. SLU J57 GND. Logic 0 signal for configuring vector bits. Wirewrapped to J53, J54, J55 and/or J56 when the corresponding vector bites) will be logical 0 for both serial line channels. SLU J58 +3 V. Logic 1 signal for configuring vector bits. Wirewrapped to J53, J54, J55 and/or J56 when the corresponding vector bites) will be logical 1 for both serial line channels. SLU 500 M8047 MXV11-A Jumper Functions (Cont) Pin Function Option J59 Seven bits parity, eight bits no parity, channel 1. Wirewrapped to ground (J65) for seven bits with parity or to + 3 V (J66) for eight bits with no parity. SLU J60 Two stop bits. Selects one or two stop bits for channel 1. Wirewrapped to ground (J65) for one stop bit or to + 3 V (J66) for two stop bits. SLU J61 Even parity. Selects odd or even parity for channel 1 when seven bits with parity (J59 wirewrapped to ground) is selected. Wirewrapped to ground (J56) for odd parity or to + 3 V (J66) for even parity. SLU J62 Seven bits parity, 8 bits no parity, channel O. Wirewrapped to ground (J65) for seven bits with parity or to + 3 V (J66) for eight bits with no parity. SLU J63 Two stop bits. Selects one or two stop bits for channel O. Wirewrapped to ground (J65) for one stop bit or to + 3 V (J66) for two stop bits. SLU J64 Even parity. Selects odd or even parity for channel 0 when seven bits with parity (J59 wirewrapped to ground) is selected. Wirewrapped to logic 0 (J65) for odd parity or to logic 1 (J66) for even parity. SLU J65 Logic O. Ground signal used for configuring serial line interfaces. SLU J66 Logic 1. + 3 V signal used for configuring line interfaces. SLU J67 Clock in. Clock input for baud rates, memory refresh and negative voltage generator. Wirewrapped to J68. Not a user option. SLU J68 Clock out. Crystal oscillator output at 19.6608 MHz. Wirewrapped to J67. Not a user option. SLU 501 M8047 Standard Factory Configuration Wirewrap From Pins To Wirewrap Level RAM Bank 0 J30 J32 J31 J31 J33 J32 L1 L1 L2 SLU Channel 0 Address 176500 J23 J24 J18 J19 L1 L1 SLU Channel 1 Address 177560 J28 J26 J25 J27 J19 J15 J14 J13 L2 L1 L1 L1 ROM Bootstrap (TU58) J37 J21 J34 J33 J29 J38 J22 J37 J39 J15 L1 L1 L2 L2 L2 SLU Vectors CHO (300) CH1 (60) J53 J54 J56 J54 J57 J52 J51 J55 L1 L1 L1 L2 SLU Parameters (8 Data Bits, No Parity, 1 Stop Bit) J59 J62 J60 J61 J59 J63 J61 J64 J63 J62 J66 J65 L1 L1 L2 L2 L2 Baud Rates CHO (38.4K) CH1 (9600) J45 J46 J50 J48 L1 Break Generation (Halt Option) J6 J7 L1 Crystal Clock J68 J67 L1 Function 502 L1 L1 M8047 Configuring the RAM The RAM can be configured to start on any 8KB boundary below 64KB. Because of this restriction, the MXV 11 (8KB version) is not usable for memory above 56KB. The MXV 11 can be used in 18-bit memory address systems, but it is restricted to being assigned to the memory area at or below 56KB. Five wirewrap terminals, J30 through J34, select the starting address. The following figure shows the jumper configurations required to obtain the desired starting addresses. 17 I a 16 a : 15 14 I 13 11 12 J3< J3< J30 10 09 08 07 06 05 04 03 02 01 00 I 1a 1a Ia _ FACTORY CONFIGURED 1 = CONNECT JUMPER TO J34 2 = CONNECT JUMPER TO J33 RAM Starting Address Selection Configuring the ROM Depending on the ROM type, the module's capacity is 1K, 2K, or 4K words using a pair of 1024 X 8-, 2048 X 8-, or 4096 X 8-bit ROMs respectively. The user configures jumpers on the module for the ROM type being used. The actual procedure for loading data into EPROMs, PROMs (or writing specifications for masked ROMs) will vary depending on the manufacturer, and is beyond the scope of this section. The user must refer to the manufacturer's data sheets and to the chapter, "Using PROMs" in the Microcomputer Processor Handbook, EB-18451-20. The user must be aware of the relationship of the EPROM, PROM, or ROM pins to the LSI-11 data bits, and the relationship of the pins to the memory address bits. Refer to the following figure for ROM socket pin assignments. All ROMs used on the MSV 11-A must conform to these pin assignments. The factory configuration allows for using the MSV 11-A2 bootstrap ROMs. Configuring the Bootstrap ROM - The ROM can be configured to operate in the I/O page to support bootstrap programs. The address area contains 256 words from 173000 to 173776 (773000 to 773776 for the LSI-11 /23). The MXV 11-A is configured at the factory to allow for using the MXV 11-A2 TU58 bootstrap. To reconfigure the MXV 11-A to use the disk bootstrap, remove jumper J29 to J 15 and install jumper J29 to J 16. 503 M8047 A08 H 23 [J------r.)(IJ29 A07 H A06 H 21 L J - - - - { ) ( ] J39 A05 H A04 H U---~)(]J38 A03 H A02 H 18 AOI H 17 (008 H) 000 H ~---f')(lJ37 16 (009 H) 001 H 10 (010 H) 002 H 11 GNO 12 15 NOTE: DATA OUT PINS SHOWN IN PARENTHESES REFER TO THE HIGH 8YTE SOCKET XE67. DATA OUT PINS 000 H THROUGH 007 H REFER TO THE LOW 8YTE SOCKET XE57. MXV 11-A ROM Socket Pin Assignment ROM Bank Selection - If the MXV 11-A sockets are used for program ROM instead of a bootstrap ROM, the memory must be selected by a jumper connecting J20 to J21. When main ROM memory is selected, the entire 4K word bank is enabled. If a 1K or 2K ROM is used, it will "wraparound" and give invalid data, depending on how the address lines are configured when the nonexisting ROM area is addressed. Main memory may be positioned in bank 0 or bank 1. To position the ROM in bank 0, jumper J 10 to J 11. To position the ROM in bank 1, jumper J9 to J 11. Configuring the Specific ROM Types - Additional jumpers must be connected depending on the type of ROM used. The "EPROM Address Jumpers" table describes the jumper configuration when using typical ROMs such as the Intel 2716 (2K X 8) or 2732 (4K X 8) EPROMs. The user must refer to the manufacturer's data sheets when configuring jumpers for other ROM types. The function of wirewrap pins J29, J38, J37, and J39 are shown in the following table. These pins are to be connected as required to pins J33 through J40. 504 M8047 EPROM Address Jumpers 2716 ROM Function Bank 0 From to Bank Enable Bit 09 Input Address or Enable Address or Enable Address or Enable J20 J29 J38 J37 J39 J21 J15 J36 J33 J40 2732 ROM Bank 1 BankO Bank 1 to to to J21 J15 J36 J33 J40 J21 J15 J36 J35 J33 J21 J15 J36 J35 J34 CONFIGURING THE SERIAL LINE UNITS Serial Line Register Address Selection Four device registers (RCSR, RBUF, XCSR, and XBUF) are provided for each of the two serial lines. Jumpers are configured to establish separate base addresses for each serial line as shown. • Serial port 0 may be assigned to one of the four starting addresses: 176500, 176510, 176520, 176530. • Serial port 1 may be assigned addresses in two ranges. The first range starts at 176500 and covers the eight starting addresses from 176500 to 176570. The second range starts at 177500 and also contains eight possible starting addresses, including the standard console address, 177560. Since several other standard DIGITAL devices use addresses in this second range, it is recommended that only the console address be used. The format of an SLU address is shown in the following figure. Note that bits 13- 17 are neither configured nor decoded by the MXV 11-A module. These bits are decoded by the bus master module as the bank 7 select (BBS7 L) bus signal. This signal becomes active only when the I/O page is accessed. Bit 0 is used as the byte pointer. 00 = RCSR 01 = RBUF 10 = XCSR 11 = XBUF 1 = RANGE 2 0= RANGE 1 . BAN K SE LECT 7 I NOTE: JUMPER POSTS ARE WIRED TO A HIGH ADDRESS LINE FOR A 1 AND TO A LOW ADDRESS LINE FOR A O. REFER TO TABLES 7 AND B FOR JUMPER CONFIGU· RATIONS. .----"----, SERIAL LINE 0 J26 SERIAL LINE 1 J2& MXV 11-A SLU Address Format 505 M8047 Bits 1 and 2 select one of the four device registers within the addressed serial line. Bits 3 and 4 are used to select one of four possible device addresses for serial line O. Bits 3, 4, 5, and 9 are used to select the device addresses in two ranges for serial line 1 (console). The following table describes the jumper combinations to select one of four device addresses for serial line 0 (I/O). Serial Line 0 Address Jumpers Address (Octal) Jumper Posts J23 to J24 to 176500 J 18 (Logic 0) J 19 (Logic 0) Factory Configuration 176510 J 18 (Logic 0) J 12 (Logic 1) 176520 J13 (Logic 1) J19 (Logic 0) 176530 J13 (Logic 1) J12 (Logic 1) NOTE Logic 1 J13 (A04 H) J12 (A03 H) Logic 0 J18 (A04 L) J19 (A03 L) Serial line 1 may have 16 possible device addresses in two ranges. The following table describes the jumper combinations to select the eight device registers available in range 1. Only one device address is used in range 2. Serial Line 1 Address Jumpers Address (Octal) Range 1 J26 to Jumper Posts J25 J27 J28 to to to 176500 176510 176520 176530 176540 176550 176560 176570 J16 J16 J16 J16 J16 J16 J16 J16 J17 J17 J17 J17 J14 J14 J14 J14 J18 J18 J13 J13 J18 J18 J13 J13 J19 J12 J19 J12 J19 J12 J19 J12 J15 J14 J13 J19 Range 2 177560 (See the following Note.) 506 M8047 NOTE Factory configurations use only one address in range 2 to avoid possible device conflicts. The remaining addresses are pre-assigned to other devices. Logic 1 J1S (A09 H) J14 (AOS H) J13 (A04 H) J12 (A03 H) Logic 0 J16 (A09 L) J17 (AOS L) J18 (A04 L) J19 (A03 L) Control/Status Register The MXV 11-A has two control/status registers (CSRs) for each of its two serial line units. The following figure shows the control/status registers and the read/write data registers. Transmitter control/status registers 0 and 1 (XCSRO and 1) and receiver control/status registers 0 and 1 (RCSRO and 1) operate with serial lines 0 and 1, respectively. Both serial line units have the same bit assignments. There are four registers for each serial line. They are sequential in this order: 0, receiver status; 2, receiver data; 4, transmitter status; and 6, transmitter data. All unused bits are read as O. 507 M8047 15 14 13 12 11 10 09 08 00 RCSR (NOT USED) RECEIVER DONE (READ ONLY) RECEIVER INTERRUPT ENABLE (READIWRITE) 07 06 05 04 03 02 01 00 RBUF RECEIVE DATA (7,8 BIT DATA IS RIGHT JUSTIFIED.) IF BIT UNUSED = 0 (READ ONLY) 15 14 13 12 11 10 09 08 05 04 03 02 01 XCSR (NOT USED) (NOT USED) TRANSMIT READY (READ ONLY) TRANSMIT BREAK (READIWRITE) TRANSMIT INTERRUPT ENABLE (READIWRITE) XBUF 15 14 13 12 11 10 09 08 0 0 0 0 0 0 0 : I I : : : : : 07 06 05 04 03 02 01 0 (NOT USED) TRANSMIT DATA (7, B BIT DATA IS RIGHT JUSTIFIED.) (WRITE ONLY) ON READ = 0 NOTE ONE OF FOUR CHANNELS SHOWN. FORMAT THE SAME FOR ALL CHANNELS, MXV11-A SLU CSR Formats 508 00 M8047 Bit Assignments for the Receiver Status Register Bit Function 6 Interrupt enable, read/write. A 1 enables receiver interrupts, a 0 disables interrupts. Cleared by initialize. 7 Receiver done, read only. A 1 indicates that the serial interface has received a character. If enabled by bit 6, receiver done will request an interrupt. Receiver done is cleared by reading the receiver data register or by initialize. 0-7 Data bits, read only. Bit 0 is the least significant bit and bit 7 is the most significant. If seven data bits plus parity is selected, bit 7 will always read as a o. 12 Parity error, read only. A 1 indicates that the word being read in bits 0 through 6 has a parity error. Bit 12 will always read 0 when eight data bits and no parity are selected. Cleared when read, or by initialize. 13 Framing error, read only. A 1 indicates that a start bit was detected, but there was no corresponding stop bit. A framing error will be generated when a break is received. Cleared when read, or by initialize. 14 Overrun error, read only. A 1 indicates that a word in the receiver buffer had not been read when another word was received and placed in the receiver buffer. Cleared when read, or by initialize. 15 Error, read only. A 1 indicates that one or more of bits 12, 13, and 14 are 1. Cleared when read, or by initialize. 509 M8047 Bit Assignments for the Transmitter Status Register Bit Function o Break, read/write. When set to a 1, bit 0 causes the serial output signal to go to a space condition. A space condition longer than a character time causes a framing error when it is received and is regarded as a break. Cleared by writing a 0, or by bus initialize. 6 Interrupt enable, read/write. A 1 enables transmitter interrupts; a o disables interrupts. Cleared by initialize. 7 Transmitter ready, read only. A 1 indicates that the serial interface is ready to accept a character into the transmitter data register. If enabled by bit 6, transmitter ready will request an interrupt. Transmitter ready is cleared when data is written into the transmitter data register. It is set by initialize. 0-7 Data bits, write only. Bit 0 is the least significant bit and bit 7 is the most significant bit. If seven data bits plus parity are selected, bit 7 will not be transmitted. The transmitter data register will read all Os. Interrupt Vector Selection Two consecutive interrupt vectors (one for receive and one for transmit) are provided for each of the two serial lines. The interrupt vector format is shown in the following figure. Each SLU port can be independently configured to operate in one of two ranges: 000 to 074, or 300 to 376. 17 16 15 14 13 12 11 10 09 NOTE BITS 3 THROUGH 7 MAY BE WIRED TO ONE OF FOUR WIREWRAP POSTS J51 (VEe 0), J52 (VEe 1), J57 (GNDI OR J58 (+3 VI 00 J56' J55 J54 J53 1 = TX 2 = Rev MXV 11-A Interrupt Vector Format The following table lists the vector addresses that may be assigned to the serial lines. Note that all vector addresses in the 000 to 074 range, except 060, are reserved vector locations. The jumper selectable bits are 3 through 7. Bits 6 and 7 are wired together. 510 M8047 Serial Line Vector Addresses Serial Line 1 (Console) Serial Line 0 (I/O) 000 010 020 DIGITAL Reserved 030 Do not use 040 050 060 Console 070 DIGITAL Reserved 300 310 320 330 340 350 360 370 The following example illustrates the procedure for configuring the vector addresses. Assume that 60 is the address for serial line 1 (console) and 310 is the address for serial line 0 (I/O). The example describes the relationship between the vector bases, vector address bits, and the jumper posts. The jumpers are configured using the following four rules. 1. If a bit = 1 in both vector bases, it is tied to J58 (logic 1). 2. If a bit = 0 in both vector bases, it is tied to J57 (logic 0). 3. If a bit = 1 for serial line (vector 1). and a 0 for serial line 0, it is tied to J52 4. If a bit = 0 for serial line (vector 0). and a 1 for serial line 0, it is tied to J51 Interface Connector Pins Two 10-pin connectors (one for each serial line) are provided on the MXV 11-A module. Connector pins and signal functions are described in the following table and shown in the following figure. TYPICAL INTERFACE CONNECTOR 1 OF 2 NO PIN (FOR CABLING INDEXING) MXV 11-A Connector Pins 511 TOP OF MXVll-A MODULE 1118047 MXV11-A I/O Connector Pin Functions 'in 2 3 4 5 6 7 8 9 o Signal Function UART CLOCK The baud rate clock appears on this pin. When an internal baud rate is selected, this pin is a TTL output. When no baud rate is selected on the module, this is an external baud rate input. The high level for the clock> 3.0 V. GND Transmitter output XMIT+ GND GND NC Key, pin not provided RCVReceiver input most negative Receiver input most positive RCV+ GND Power for the DL V 11-KA option + 12 V Current Loop rhe MXV 11-A module can interface with 20 rnA active or passive current oop devices when used with the DL V 11-KA option. This option consists of a DL V 11-KB (EIA to 20 rnA current loop converter) and a BD21 A-03 inter:ace cable. The MXV 11-A does not have the capability to support the reader-run portion of the DLV 11-KA option. The DLV 11-KA option is placed between the MXV 11-A serial line output and the 20 rnA current loop :>eripheral device. MXV11-A Interface Cables Cable Application Length 3C21B-05 EIA RS-232C modem cable to interface with modems and acoustic couplers (2 X 5-pin AMP female to RS-232C male). 1.5 m (5 ft) 3C20N-05 EIA RS-232C null modem cable to directly interface with a local EIA RS-232C terminal (2 X 5-pin AMP female to RS-232C female). 1.5 m (5 ft) BC20M-50 EIA RS-422 or RS-423 cable for high-speed transmission (19.2K baud) (2 X 5-pin AMP female to 2 X 5-pin AMP female). 15 m (50 ft) BC05D-10 Extension cable used in conjunction with BC21B-05. 3 m (10 ft) BC05D-25 Extension cable used in conjuntion with BC21B-05. 7.6 m (25 ft) BC03M-25 "Null modem" extension cable used in conjunction with BC21B-05. 7.6 m (25 ft) 512 M8047 NOTE "Strapped" logic levels are provided on Data Terminal Ready (DTR) and Request To Send (RTS) for operation of modems with manual provisions (such as Bell 103A data set with 804B auxiliary set). The MXV 11-A may operate with several peripheral device cables and options for flexibility when configuring systems. A variety of cables and options, as well as the primary application of each, are shown with the MXV11-A. 1. The receivers on the MXV 11 have differential inputs. Therefore, when designing an RS-232C or RS-423 cable, receive data (pin 7 on the 2 X 5-pin AMP connector) must be tied to signal ground (pins 2, 5, or 9) in order to maintain proper EIA levels (see the following figure). 2. To connect directly to a local EIA RS-232C terminal, it is necessary to use a null modem. To design the null modem into the cable, one must switch received data (pin 2) with transmitted data (pin 3) on the RS232C male connector as shown in the following figure. To mate to the 2 X 5-pin connector block, the following parts are needed: Cable Receptacle (OTY 1) AMP PN 87133-5 DEC PN 12-14268-02 Locking Clip Contacts (OTY 9) AMP PN 87124-1 DEC PN 12-14267-00 Key Pin (pin 6) (OTY 1) AMP PN 87179-1 DEC PN 12-15418-00 513 M8047 EIA RS232C MXV11 A < 5 f- -, CLEAR TO SEND ICBI I GND> 9 "- I RCV DATA> 7 I F1~10 f- ---l REQUEST TO SEND ICAI 6 f- 750D. 1/2W +12 VDV 4 --, DATA SET READY ICCI I 20 f- ---.J DATA TERMINAL READY ICDI 1A <RECEIVE DATA IBBI 2 <TRANSMITTED DATA IRAI 7 <SIGNAL GROUND lAB I 1 <PROTECTIVE GROUND IAAI "- 3 RCV DATA> B ,r XMIT DATA> 3 "- GRD> 2 J 0 CABLE MXV11-A CONNECTOR EIA RS·232C CONNECTOR 8218-05 Modem Cable 514 MODEM M8047 ~MXV"A~ - - --15.2 M (50 FT)----~ ~ -----IBC20M-50------ MXV11-A TO LOCAL TERMINAL ~~;.::...-----4.2M(14FT)----MXV11-A O BC20N-05 --~-2.7 M (9 FT) - (NOTE 2) ~ ~. EJ MXV11-AD "~----11.8 M (39 FT)----------_ --=---- -~~--_co_________co_BC21 B-05 BC03M-25 2.7 M NOTES: (9 FT) 1. MODEM USED IS A "MANUAL TYPE" SUCH AS BELL 103A WITH 804B. 2. DEC EIS RS-232C TERMINALS (VT52, LA36, LS120, ETC.) COME EQUIPPED WITH A 9 FT CABLE. NON-DEC EIA RS-232C TERMINALS ARE CONNECTED SIMILARLY EXCEPT 9 FT OF LENGTH MUST BE DEDUCTED FROM THE TOTAL CABLE LENGTH. 3. XX = CABLE LENGTH WHICH MUST BE SPECIFIED WHEN ORDERING. MXV 11-A EIA Cable Configurations 515 MB047 MXVll-A TO 20 MA TERMINAL WITH LT33-MD MODIFICATION KIT. OLVll-KA PRISOl A. A. NOTES: 1. PRISOI IS A SERIAL LINE PAPER TAPE LOADER. 2. MXVll-A WILL NOT SUPPORT DLVll-KA READER RUN CIRCUITS. 3. XX = CABLE LENGTH WHICH MUST BE SPECIFIED WHEN ORDERING. MXV 11-A 20 rnA Cable Configurations 516 M8048 M8048 MRV11-C READ-ONLY MEMORY (ROM) MODULE The MRV 11-C is a flexible, high-density ROM module used with the LSI-11 bus. The module contains 129 wirewrap pins and 16 24-pin ROM chip sockets that use a variety of user-supplied ROM chips. Masked ROMs, fusible link ROMs and ultraviolet erasable PROMs are acceptable to use. The .MRV 11-C is shipped without jumpers installed. Using 4K X 8 ROM chips, the total capacity of one M8048 module can be 64K bytes, accessible either by direct access or window mapping. Amps +5 0.8 + 12 Bus Loads Cables AC 2 None DC (plus ROM chip power) Standard Addresses Recommended window starting address 760000 Bootstrap starting address: 16-bit system 173000; 18-bit system 773000 Technical detailed information is beyond the scope of this manual. Additional information can be found in the Microcomputer Processor Handbook, EB-18451-20. 517 M8048 Compatible UV PROMs (Ultraviolet) UV PROMs Chip Array Size Maximum Memory Siz.e Intel 2758 Intel 2716 Intel 2732 Mostek MK2716 T.I. TM8 2516 T.I. TM8 2532 1K X 8 2K X 8 4K X 8 2K X 8 2K X 8 4K X 8 16K bytes 32K bytes 64K bytes 32K bytes 32K bytes 64K bytes Compatible PROMs PROM Chip Array Size Maximum Memory Size 16K bytes 16K bytes 16K bytes 32K bytes Intel 3628 1K X 8 8ignetics 828 2708 1K X 8 8ignetics 828 181 1K X 8 8ignetics 828 191 2K X 8 518 6~9 suonBoOl U!d dBJM9J!M 8- ~ ~ "Cll'\! E8O£-I:tW ·NOI.L'VOI~I.LN3al Nld d'VI::lM31::lIM I::lO~ 9t 3l8'V.L 33S tf$Y If Y £f Y Y-t>f Y-9f 06f-y "r-Y~"r Y £6f ~ or~Y Lf 8f Otf ltf t>tf 9tf 9lf Y Y Y Y /ttf er Y Y/£tf ~ ~;:::9tf Y Y Ltf Y~8tf ~_Olf 3.LA8 MOl L .L3S dlHO £l3X ~-llf Y======£lf \ t>lf ~Y9lf ~Y6lf ~Yl£f Y 3.LA8 Mal 9.L3S dlHO 6l3X 3.LA8 Mal 9.L3S dlHO 9£3X 3.LA8 Mal t> .L3S dlHO tt>3X 86f 66f Y Y Y ~Y9£f ~Y8£f It>f ~~t>t>f YY-9t>f ~~-8t>f 3.LA8 H91H L .L3S dlHO t>l3X 3.LA8 H91H 9.L3S dlHO O£3X 3.LA8 H91H 9.L3S dlHO 9£3X 3.LA8 H91H t> .L3S dlH::J It>3X YY:::::::09f Y 19f YY 99f Y yy_89f YY--09f ~~-l9f YY~99f L9f Y Y 89f 69f OLr tLr lLr t>Lr 9Lr 8Lf 08f l8f t>8f 9af t>6f 96f 96f L6f Y~6tf Y--tlf Ot>f tt>r £t>f 9t>f Lt>f 6t>f t9f £9f t>9f 99f L9f 69f t9f £9f 99f :3.LON Y Y Y Y Y Y Y Y Y 3.LA8 Mal £ .L3S dlH::J 9l3X 3.LA8 Mal l.L3S dlH::J t£3X 3.LA8 Mal t .L3S dlH::J L£3X 3.LA8 Mal o .L3S dlHO £t>3X 99f Y Y Y Y y Y Y. Y. y Y Y- Y. £Lr ~::::::9Lr y_LLf Y-6Lf 3.LA8 H91H £ .L3S dlH::J 9l3X Y ~-t8f Y Y............... £8f X Y~98f Y....... 89f Y'68f L8f 3.LA8 H91H t .L3S dlH::J 8£3X 3.LA8 H91H o .L3S dlH::J t>t>3X Y- y. y. Yy. Y. y. D~DD~D~ 8l'08W 3.LA8 H91H l.L3S dlH::J l£3X y Y 90tf 90tf LOtf 80tf 60tf Ot tf t t tf It tf £t tf t>t tf 9t tf 9t tf Lt tf 8t tf 6t tf Oltf tUf lltf £ltf t>ltf 9ltf 9ltf Lltf 8Uf 6ltf DALO-15 Jl13 All J22 I'"'D-B-1----Y-8-,51--.----..:...:..:..:.------o Jl12 Jl15 A12 Y84I--+-.---..:...:..:.=-------o J117 DB3 DRIVERS Y831--+-+-----, +5 VDC----<> J111 DB4 Y821--t-t----, Jl16 J24 +5 VDC -----<> J23 DB2 ~ 800T 085 All A12 ENABLE ~ J18 Y81 CSR ADDRESS Jl14 MEMORY BOOT ENABLE BIT 1 BIT 2 BIT 3 BIT 4 BIT 12 BIT 11 BIT 10 BIT 9 BIT 8 J17 J15 J13 J11 J12 JlO J9 J8 Ih~-rlj~..n).1 CONTROL 01 1"0 STATUS REG. J16 J14 DB1 DB2 HIGH BYTE YB5 Y84 BINARY DECODER DB3 DRIVERSYB11--t-t-..-I---t---l SELC CEO DB4 YB21-+-+-t---<.-t---i SELB CE1 085 YB31-+-+-+-I----<......, SELA CE2 CE3 J39 WINDOW ENABLE CE4 CE5 o J38 , . . . - - - - - - - - , DB1 LOW YB5 AD15 J37 DB2 !~6E YB4 DB3 DIRECT YB1 DB4 ADDRESS YB21------' DRIVERS DB5 YB31------' J34 WINDOW J69 ENABLE~ J71 DIRECT ---0 ENABLE MRV 11-C Configuration Interconnections J79 CE4 CE5 CE6 CE6 CE7 CE7 M8048 WINDOW MAPPING YES NO END MR·3879 Configuration Procedure 521 M8048 Wirewrap Pin Identification Wirewrap Pin Designation Function J1 J2 J3 J4 J5 J6 J7 J8 J9 J 10 J 11 J 12 J 13 J 14 J 15 J 16 J 17 J 18 J 19 J20 J21 J22 J23 J24 J25 J26 J27 J28 J29 J30 J31 J32 J33 J34 J35 J36 J37 J38 J39 J40 J41 J42 J43 RXCX pull-up resistor RXCX optional capacitor RXCX signal LMA TCH input for BDOUT control LMATCH for BDOUT control Window address enable ground Window address enable High byte chip enable bit A 11 CSR high byte bit 8 chip enable output High byte chip enable bit A 12 CSR high byte bit 9 chip enable output High byte chip enable least significant bit CSR high byte bit 10 chip enable output High byte chip enable intermediate bit CSR high byte bit 11 chip enable output High byte chip enable most significant bit CSR high byte bit 12 chip enable output Boot address chip enable bit A 11 Boot address chip enable bit A 12 Boot address chip enable least significant bit Boot address chip enable intermediate bit Boot address chip enable most significant bit Boot address chip enable ground reference Boot address chip enable 5 V reference Direct address bit 11 chip enable output Low byte chip enable A 11 bit CSR low byte bit 0 chip enable output Direct address bit 12 chip enable output Low byte chip enable A 12 bit CSR low byte bit 1 chip enable output Direct address bit 13 chip enable output Low byte chip enable least significant bit CSR low byte bit 2 chip enable output Direct address bit 14 chip enable output Low byte chip enable intermediate bit CSR low byte bit 3 chip enable output Direct address bit 15 chip enable output Low byte chip enable most significant bit CSR low byte bit 4 chip enable output Reserved for future DIGITAL use. Window address bit 15 compare ground Window address bit 13 compare input Window address bit 12 compare ground 522 M8048 Wirewrap Pin Identification (Cont) Wirewrap Pin Designation Function J44 J45 J46 J47 J48 J49 J50 J51 J52 J53 J54 J55 J56 J57 J58 J59 J60 J61 J62 J63 J64 J65 J66 J67 J68 J69 J70 J71 J72 J73 J74 J75 J76 J77 J78 J79 J80 J81 J82 . J83 J84 J85 J86 Window address bit 14 compare input Window address bit 14 compare ground Window address bit 15 compare input Window address bit 16 compare ground Window address bit 16 compare input Window address bit 13 compare ground Window address bit 17 compare input Window address bit 17 compare ground Window address bit 12 compare input Direct address 32K memory limit output Direct address 16K memory limit output Direct address memory limit input Direct address 8K memory limit output Direct address bit 17 compare ground Direct address bit 16 compare input Direct address bit 16 compare ground Direct address bit 17 compare input Direct address bit 15 compare ground Direct address bit 15 compare input Direct address bit 14 compare ground Direct address bit 14 compare input Direct address bit 13 compare ground Direct address bit 13 compare input CSR high byte bit 15 enable ground CSR high byte bit 15 enable input High byte chip enable window address function High byte chip enable direct address function High byte chip enable function select drivers Bit 7 chip select enable input Bit 7 chip enable decoder output Bit 6 chip select enable input Bit 6 chip enable decoder output Bit 5 chip select enable input Bit 5 chip enable decoder output Bit 4 chip select enable input Bit 4 chip enable decoder output Bit 3 chip select enable input Bit 3 chip enable decoder output Bit 2 chip select enable input Bit 2 chip enable decoder output Bit 1 chip select enable input Bit 1 chip enable decoder output Bit 0 chip select enable input 523 M8048 Wirewrap Pin Identification (Cont) Wirewrap Pin Designation Function J87 J88 J89 J90 J91 J92 J93 J94 J95 J96 J97 J98 J99 J100 J101 J102 J103 J104 J105 J106 J107 J108 J109 J110 J 111 J 112 J 113 J 114 J 115 J 116 J 117 J118 J119 J120 J121 J122 J123 J124 J125 J126 J127 J128 J129 Bit 0 chip enable decoder output Boot address enable ground Boot address enable DAL 4 CSR address select signal DAL 4 CSR address select ground DAL 1 CSR address select signal DAL 1 CSR address select ground DAL 2 CSR address select signal DAL 2 CSR address select ground DAL 3 CSR address select signal DAL 3 CSR address select ground Pin 18 input for chip set 5 Chip wirewrap interconnection for chip set 5 Pin 20 input for chip set 5 (chip enable 5) Pin 18 input for chip set 4 Chip wirewrap interconnection for chip set 4 Pin 20 input for chip set 4 (chip enable 4) Pin 18 input for chip set 6 Chip wirewrap interconnection for chip set 6 Pin 20 input for chip set 6 (chip enable 6) Pin 18 input for chip set 7 Chip wirewrap interconnection for chip set 7 Pin 20 input for chip set 7 (chip enable 7) Reserved for future DIGITAL use. ROM interconnection, ground reference Chip enable bit bus input Address bit A 11, used as chip input A 10 Chip interconnection loop (to wirewrap pins) Address bit A 12, used as chip input A 11 Chip interconnection loop for chip pin 21 ROM interconnection + 5 Vdc voltage reference Pin 18 input for chip set 0 Chip wirewrap interconnection for chip set 0 Pin 20 input for chip set 0 (chip enable 0) Pin 18 input for chip set 1 Chip wirewrap interconnection for chip set 1 Pin 20 input for chip set 1 (chip enable 1) Pin 18 input for chip set 2 Chip wirewrap interconnection for chip set 2 Pin 20 input for chip set 2 (chip enable 2) Pin 18 input for chip set 3 Chip wirewrap interconnection for chip set 3 Pin 20 input for chip set 3 (chip enable 3) 524 M8048 Control and Status Register Each MRV 11-C board uses one 16-bit control and status register located in the system I/O page to determine mapping of ROM segments into windows in the window mapped mode. The default address for this CSR is 177000 (777000 in the PDP-11 /23 system). The valid address range for CSRs is 177000 to 177036 (777000 to 777036 on PDP-11 /23s). The CSR contains a 5-bit read/write field for each window. The number stored in this field (0 to 31 10) selects the desired 2Kb region from the MRV 11-C board to be associated with the window in question. CSR bits 0 through 4 control the mapping of the low address window, window O. The low five bits of the upper byte (bits 8 through 12) control the mapping of window 1. The MRV11-C optionally provides a window enable/disable capability. When this option is selected, bit 15 of the CSR is used to enable or disable window response under program control. When bit 15 is a 0, the board will respond to references to the CSR or DATI or DA TIO references to either of the windows. When bit 15 is a 1, only the CSR will respond. If the enable/disable option is not selected, bit 15 of the CSR will be read only and will always be O. The enable/disable bit has no effect on direct mode addressing or the bootstrap window capability. If enable/disable option is used, bit 15 on system initializes, disabling the board. Control and Status Register Addresses CSR Address Bit 4 J90 to J91 Bit 3 J96 to J97 Bit 2 J94 to J95 Bit 1 J92 to J93 177000· 177002 177004 177006 177010 177012 177014 177016 177020 177022 177024 177026 177030 177032 177034 177036 R R R R R R R R I I I I I I I I R R R R I R I R I R I R = jumper removed. R I I R R R I I I I R I I R R R R R I I I I I I R R I I R R I R I R I R I I = jumper installed. • Default address NOTE Install J67 to J68 to allow the use of bit 15 of the CSR. 525 M8048 MRV11-C Direct Addressing Starting Address Starting Address Bit 17 Bank 57 to 60 Bit 16 59 to 58 Bit 15 61 to 62 Bit 14 63 to 64 Bit 13 65 to 66 0 20000 40000 60000 100000 120000 140000 160000 0 1 2 3 4 5 6 7 I I I I I I I I I I I I I I I I I I I I I I I R R I R R R R I I I R R I 200000 220000 240000 260000 300000 320000 340000 360000 10 11 12 13 14 15 16 17 I I I I I I I I R R R R R R R R I I I I I I I R R I R R R R I I I R R I 400000 420000 440000 460000 500000 520000 540000 560000 20 21 22 23 24 25 26 27 R R R R R R R R I I I I I I I I I I I I I I I R R I R R R R I I I R R I 600000 620000 640000 660000 700000 720000 740000 760000 30 31 32 33 34 35 36 37 R R R R R R R R R R R R R R R R I I I I I I R R I R R R R I I I R R I R = jumper removed. I = jumper installed. 526 R R R R R R R R R R R R I R R R R M8048 Using Multiple Boards Up to 16 MRV11-C boards may be configured in a single system. When multiple boards are present, each board has a unique control and status register address assigned in increasing order from 177000 (777000 in PDP11/23 systems). Each board can have a unique 4Kb area of the physical address space set aside for its windows, but it is also possible to share one 4Kb area of the address space among all MRV 11-C boards installed in the system. This is done by using the enable/disable capability discussed earlier. When enable/disable is implemented, the disable bit in the CSR will be set automatically by BINIT on the bus or by execution of the RESET instruction. Therefore, the initial state of the system will have all boards disabled. To access a particular segment of ROM in this multiboard configuration, the programmer first enables the desired board and maps the segment. When access to that segment is completed, the board is again disabled to allow another board to be selected some other time. Chip Enable Jumpers Sockets Enabled Chip Enable Signal Wirewrap Jumpered Pins XE43,XE44 XE37,XE38 XE31, XE32 XE25,XE26 XE41, XE42 XE35, XE36 XE29,XE30 XE23,XE24 CEO J86 to J87 J84 to J85 J82 to J83 J80 to J81 J78 to J79 J76 to J77 J74 to J75 J72 to J73 CE1 CE2 CE3 CE4 CE5 CE6 CE7 NOTE J40 and J110 are unused at this time. ROM Chips The ROM is provided by the user and consists of up to 16 chips that are inserted into prewired sockets. The chips will be either 1K X 8 bit, 2K X 8 bit, or 4K X 8 bit ROMs. When the MRV 11-C is fully populated, the result will be either 16K, 32K, or 64K bytes of memory. These ROMs can be supplied by a variety of vendors and the basic configuration for many of the ROMs is standardized except for pins 18, 19, 20, and 21. The configuration of these pins will vary depending upon the size of the ROM and the vendor who supplies them. The user should verify the vendor's specifications in order to determine if a particular ROM can be used on the MRV 11-C. 527 M8048 The MRV 11-C module is configured so that the user can select the signals that are applicable to pins 18, 19, and 21. The board provides wirewrap pins for the user to select the A 11, A 12, 5 Vdc or ground. There are three individual loops that interconnect all chips and three wirewrap pins available for each individual chip. Wirewrap pin J 112 interconnects pin 19 of all the chips and pin J 116 interconnects pin 21 of all the chips; these are normally designated as the A 10 or A 11 inputs to the chips. Wirewrap pin J 114 interconnects wirewrap pins that are individually associated with each chip. Pin 18 of each chip is individually wired to a wirewrap pin and chip pin 20 is wired to the chip enable signal. Chip pin 20 is also individually wired_ to a wirewrap pin. The user must determine from the vendor's specifications which signals apply to which pins and must install jumper wires as needed to configure an operational module. INTEL 2716 INTEL 2732 PIN CONFIGURATION PIN CONFIGURATION A7 24 Vee A7 A6 23 A8 A5 22 A9 A4 21 Vpp __ TO +5 VDC A3 20 A2 19 Al 24 VCC A6 23 A8 A5 22 A9 A4 21 All A3 20 OE/Vpp A l O - TO All H A2 19 18 I T - TOOE AID cr __ TOOE Al 18 ~ BE_ TOCE AD 17 AD 17 07 00 16 06 00 16 06 01 15 05 01 15 05 02 11 14 04 02 11 14 04 GND 12 13 03 GND 12 13 03 2K X 8 ROM 4K X 8 ROM MRV 11-C ROM Pin Configuration Sample 528 TO Al2 H TOCE _TOAll H 07 10 _ M8049 M8049 DRV11-J GENERAL PURPOSE PARALLEL LINE INTERFACE Amps +5 Bus Loads AC 2 + 12 1.BA DC 1 Cables BC02D-XX BCOBY-XX BC05W-XX (For loopback half-twist connection) Standard Addresses CSR DBR A B C 764160 764162 764164 764166 764170 764172 D 764174 764176 Standard Vectors Software programmable in the range 0000 8 -1774 8 , Diagnostic Programs Refer to Appendix A. NOTE Both the XXDP + diagnostics and the DEC/X 11 module require the installation of a BC05W-XX loop back cable. Related Documentation DRV 11-J Field Maintenance Print Set (MP-00B66-00) DRVII-J User Guide (EK-DRV11J-UG) Technical, detailed information is beyond the scope of this manual. Additional information can be found in the Microcomputer Interfaces Handbook, EB-20 175-20. 529 M8049 Device Address There are eight device registers on the M8049 module that can be individually addressed by the computer program. These registers are divided into four control status registers (CSR A, B, C, D), and four data buffer registers (DBR A, B, C, and D). Addresses for the module are selectable from location 760000 octal through 777600 octal address range. When more than one DRV 11-J is desired, the module's starting address must be assigned in descending order and separated by 20 octal addresses. Example: the first module will be 760060, the second 760040, and the third, 760020 octal. Nine address jumpers (W 1 through W9) are installed or removed to establish a base device register address. Note that address bits A 13 through A 15 are neither configured nor decoded by the module. These bits are decoded by the bus master module as the bank 7 select (BBS7L) bus signal. Address bit 0 is used by the program to select a high-byte or low-byte operation. Address bits 1 through 3 are used to select one of the eight device registers in the addressed module. '------v----' BBS7 L = 1 (LI '---v----' ADDRESS JUMPERS REGISTER SE LECTION BYTE SE LECT 1 = HI BYTE 0= LO BYTE INSTALLED = ALLOWS MATCH TO OCCUR WITH A 1 (LOW) ON THE CORRESPONDING BUS LINE. REMOVED = ALLOWS MATCH TO OCCUR WITH A a (HIGH) ON THE CORRESPONDING BUS LINE. DRV 11-J Device Address Format 530 M8049 DRV11-J Registers Mnemonic Description Address (Octal)" CSRA DBRA CSRB DBRB CSRC DBRC CSRD DBRD Control Status Register A Data Buffer Register A Control Status Register B Data Buffer Register B Control Status Register C Data Buffer Register C Control Status Register D Data Buffer Register D 7XXXXO 7XXXX2 7XXXX4 7XXXX6 7XXX10 7XXX12 7XXX14 7XXX16 • XXXX is jumper selectable between 60000 and 77760 octal in a modulas of 20 octal. Interrupt Vector Addresses The DRV 11-J may be programmed to operate in systems requiring either vectored interrupts or polled interrupts. If the DRV 11-J is used in a system that required vectored interrupts, the interrupt vector addresses must be programmed into a 64 X a-bit RAM (vector address memory) contained in two interrupt controller chips (E2 and E 10). Each interrupt controller chip may store a maximum of 32 interrupt vector addresses. CSRB bits D 07 -00 are used in conjunction with CSRA bits 07 -00 to program the 32 vector addresses for group 1 interrupt control. CSRD bits 07 -00 are used in conjunction with CSRC bits to program the 32 vector addresses for group 2 interrupt control. Note that vector address bits V9 through V2 are programmed by CSRB or CSRD bits D7 through DO, respectively. A total of 64 vector addresses in the 0000 through 1774 octal range may be stored in the vector address memory. To avoid device conflicts, refer to Appendix A of the Microcomputer Interfaces Handbook, EB-20 175-20, when assigning vector addresses. 15 14 13 12 11 10 09 0 V9 I I D7 I 08 07 V8 V7 I D6 06 , V6 I D4I D5 I 05 04 03 V5 V4 V3 I I D3 I I D2 T CSRB (GROUP 11 OR CSRD (GROUP 21 DRV 11-J Vector Address Format 531 I D1 02 I 01 I I DO 00 0 V2 I M8049 ( J2 ( Jl U PORT C AND D U PORT A AND B SOFTWARE CONTROLLED VECTOR INTERRUPT .J4~OO 00 B lBJ3c:=::::J Wl0 A DRV 11-J Jumper Locations 532 M8049 DRV11-J Factory Jumper Configuration Jumper Function Jumper State" W1 A12 R W2 A 11 I W3 A10 R W4 A9 R W5 A8 R W6 A7 R W7 A6 I W8 A5 I W9 A4 I CSRA DBRA CSRB DBRB CSRC DBRC CSRD DBRD I Reserved for future use. I DRV 11-J monitors group 2 vectored interrupts using port A I/O bits 11 -08 and USER RPL Y (A through D) signals (default configuration). W10 W11 Group Vector Interrupts Function This arrangement of jumpers W 1 through W9 assigns the device address 764160 octal to the first of eight addressable bus registers. With a starting address of 764160 octal, the remaining bus registers are automatically assigned the following contiguous addresses. • R = removed = o. I = installed = 1. 533 764160 764162 764164 764166 764170 764172 764174 764176 M8049 12 UNUSED CSRA Bit Assignments CSRA Bit Function and Description Bit Function 07-00 C/S7-C/SO - These bits are used in conjunction with CSRD bits (07 -00) to program interrupt control group 1. They contain status information when read, and command words when written. Unaffected by BINIT. Read/write. 08 Direction A (DIR A) - Used for controlling DBRA. This bit, in conjunction with the USER RDY signal, controls the direction of data transfer. When the DIR bit is cleared, the ORV 11-J ROY output signal is asserted and the ORV 11-J is the input device. When set and the USER ROY signal is asserted, the ORV 11-J is the output device. The negation of either OIR or USER ROY will cause the DRV 11-J outputs to remain in their high impedance state. Cleared by BINIT. Read/write. 09 Interrupt Enable (IE) - Enables the DRV 11-J to generate processor interrupts when set. Used to enable both group 1 and group 2 interrupts. Cleared by BINIT. Read/write. 14-10 Unused. Read as Os. 15 User Ready A (RDY A) - Used for controlling OBRA. When read, yields the state of the USER ROY signal. A 0 equals negated, and a 1 equals asserted. It is used in conjunction with the DIR bit to enable DRV 11-J output operations. The user device asserts this signal when it desires the ORV 11-J to output data. Unaffected by BINIT. Read only. 534 M8049 15 14 13 12 11 10 09 08 07 06 05 04 03 02 CSRB Bit Assignments CSRB Bit Function and Description Bit Function 07-00 D7 -DO - These bits are used in conjunction with CSRA bits (07 -00) to program interrupt control group 1. They contain information selected by the command word loaded through CSRA. The registers available are the IRR, ISR, ACR, IMR and the vector address memory. Unaffected by BINIT. Read/write. 08 Direction B (DIR B) - Used for controlling DBRB. This bit, in conjunction with the USER RDY signal, controls the direction of data transfer. When the DIR bit is cleared, the DRV 11-J RDY output signal is asserted and the DRV 11-J is the input device. When set and the USER RDY signal is asserted, the DRV 11-J is the output device. The negation of either DIR or USER RDY will cause the DRV 11-J outputs to remain in their high impedance state. Cleared by BINIT. Read/write. 14-09 Unused. Read as Os. 15 User Ready B (RDY B) - Used for controlling DBRB. When read, yields the state of the USER RDY signal. A 0 equals negated, and a 1 equals asserted. It is used in conjunction with the DIR bit to enable DRV 11-J output operations. The user device asserts this signal when it desires the DRV 11-J to output data. Unaffected by BINIT. Read only. 535 M8049 15 14 13 12 11 RgV 1 4 - - - - U N U S E D - - - - - t CSRC Bit Assignments CSRC Bit Function and Description Bit Function 07-00 C/S7-C/SO - These bits are used in conjunction with CSRD bits (07 -00) to program interrupt control group 2. They contain status information when read and command words when written. Unaffected by BINIT. Read/write. 08 Direction C (DIR C) - Used for controlling DBRC. This bit, in conjunction with the USER ROY signal, controls the direction of data transfer. When the DIR bit is cleared, the DRV11-J ROY output signal is asserted and the DRV 11-J is the input device. When set and the USER ROY signal is asserted, the DRV 11-J is the output device. The negation of either DIR or USER ROY will cause the DRV 11-J outputs to remain in their high impedance state. Cleared by BINIT. Read/write. 14-09 Unused. Read as Os. 15 User Ready C (ROY C) - Used for controlling DBRC. When read, yields the state of the USER ROY signal. A 0 equals negated, and a 1 equals asserted. It is used in conjunction with the DIR bit to enable DRV 11-J output operations. The user device asserts this signal when it desires the DRV 11-J to output data. Unaffected by BINIT. 15 14 13 12 11 10 09 08 07 06 05 D5 CSRD Bit Assignments 536 I 04 03 02 01 00 D41 D3 D2 D1 DO M8049 CSRD Bit Functions and Description Bit Function 07-00 07 -DO - These bits are used in conjunction with CSRC bits (07 -00) to program interrupt control group 2. They contain information selected by the command word loaded through CSRC. The registers available are the IRR, ISR, ACR, IMR and the vector address memory. Unaffected by BINIT. Read/write. 08 Direction 0 (DIR D) - Used for controlling DBRD. This bit, in conjunction with the USER ROY signal, controls the direction of data transfer. When the DIR bit is cleared, the DRV 11-J ROY output signal is asserted and the DRV 11-J is the input device. When set and the USER ROY signal is asserted, the DRV11-J is the output device. The negation of either DIR or USER ROY will cause the DRV 11-J outputs to remain in their high impedance state. Cleared by BINIT. Read/write. 14-09 Unused. Read as Os. 15 User Ready 0 (ROY D) - Used for controlling DBRD. When read, yields the state of the USER ROY signal. A 0 equals negated, and a 1 equals asserted. It is used in conjunction with the DIR bit to enable DRV 11-J output operations. The user device asserts this signal when it desires the DRV 11-J to output data. Unaffected by BINIT. Read only. 15 I· \: 14 13 12 11 1/0 BUS <15:8> HIGH BYTE READ 10 09 07 08 06 ·1· .1. 05 04 03 1/0 BUS <7:0> LOW BYTE READ WORD READIWRITE 02 01 00 ·1 :1 Data Buffer Register Bit Assignment Data Buffer Registers The data buffer registers (DBRA, DBRB, DBRC, and DBRD) are 16-bit wordaddressable registers that contain output data when written and input data when read. In an output mode, reading the input register will yield the output buffer contents. The output buffers DBRA through DBRD are not cleared by initialize. The bit assignment is the same for all four registers. 537 M8049 Programmed Data Transfer Input and output data transfers may be performed under program control by addressing the data buffer registers (DBRA, B, C, or D) and then reading or writing the data. Data is transferred on a 16-bit word-by-word basis by reading or writing the appropriate data buffer. Interfacing to User's Device Two board-mounted 50-pin male connectors (J 1 and J2) interface the DRV 11-J to the user device. Connector J 1 is used to interface the port A and port B signals, while J2 is used for the port C and port D signals. Location of the connector pins is shown below with the "interface signal names and their respective connector pins listed in the table that follows. DRV 11-J I/O Connector Pin Locations I/O Connector Pin Functions J1 J2 Signal Name Connector Pin Signal Name Connector Pin DRV11-J RDY A DRV11-J RPLY A USER RDY A USER RPLY A A I/O 15 A I/O 14 A I/O 13 A I/O 12 A I/O 11 A I/O 10 J1-29 J1-33 J 1-31 J1-27 J1-45 J1-46 J1-43 J1-49 J1-48 J 1-44 DRV11-J RDY D DRV11-J RPLY D USER RDY D USER RPLY D D I/O 15 D I/O 14 D I/O 13 D I/O 12 D I/O 11 D I/O 1C J2-29 J2-33 J2-31 J2-27 J2-45 J2-46 J2-43 J2-49 J2-48 J2-44 538 M8049 I/O Connector Pin Functions (Cont) Signal Name J1 Connector Pin Signal Name J2 Connector Pin A I/O 9 A I/O 8 A I/O 7 A 1/06 A I/O 5 AI/04 A I/O 3 A I/O 2 A I/O 1 A I/O 0 J1-50 J1-47 J 1-41 J1-36 J1-42 J1-35 J1-40 J1-38 J1-39 J1-37 01/09 01/08 01/0 7 01/0 6 01/0 5 01/04 01/03 01/02 01/0 1 01/00 J2-50 J2-47 J2-41 J2-36 J2-42 J2-35 J2-40 J2-38 J2-39 J2-37 GNO GNO GNO GNO GNO J 1-26 J1-28 J1-30 J1-32 J1-34 GNO GNO GNO GNO GNO J2-26 J2-28 J2-30 J2-32 J2-34 ORV11-J ROY B ORV11-J RPLY B USER ROY B USER RPLY B B I/O 15 B I/O 14 B I/O 13 B I/O 12 B I/O 11 B I/O 10 B I/O 9 B I/O 8 B I/O 7 B I/O 6 BI/O 5 B I/O 4 BI/O 3 BI/O 2 B I/O 1 B 1/00 GNO GNO GNO GNO GNO J1-20 J1-24 J 1-22 J 1-18 J1-6 J1-5 J1-8 J 1-2 J1-3 J1-7 J 1-1 J1-4 J 1-10 J 1-15 J1-9 J 1-16 J 1-11 J 1-13 J 1-12 J 1-14 J 1-17 J 1-19 J 1-21 J1-23 J1-25 ORV11-J ROY C ORV11-J RPLY C USER ROY C USER RPLY C C I/O 15 C I/O 14 C I/O 13 C I/O 12 C I/O 11 C I/O 10 C 1/09 C I/O 8 C I/O 7 C I/O 6 C I/O 5 C 1/04 C I/O 3 C I/O 2 C I/O 1 C 1/00 GNO GNO GNO GNO GNO J2-20 J2-24 J2-22 J2-18 J2-6 J2-5 J2-8 J2-2 J2-3 J2-7 J2-1 J2-4 J2-10 J2-15 J2-9 J2-16 J2-11 J2-13 J2-12 J2-14 J2-17 J2-19 J2-21 J2-23 J2-25 539 M8049 I/O Signal Functions Signal Name" Function DRV11J ROY [X] This signal is asserted by the DRV 11-J to inform the user that data may be placed on the I/O bus associated with the signal. It is asserted when the corresponding DIR bit is cleared. DRV11J RPL Y [X] This signal is asserted when the DRV 11-J has accepted data (DRV 11-J is the input device) by reading the corresponding data buffer with the associated DIR bit cleared, or when data is available for the user device (DR V 11-J is the output device) by writing the corresponding data buffer with the associated DIR bit set. [X] I/O < 15:00> These are the 16 three-state data buffer inputs and outputs. USER ROY [X] This signal is asserted by the user device to inform the DRV 11-J that it requires input data (DRV 11-J is the output device) and, in conjunction with the associated DIR bit, enables the DRV 11-J th ree-state outputs. USER RPL Y [Xl This signal is asserted by the user device when data is accepted (DRV 11-J is the output device) or when data is available (DRV11-J is the input device). • [Xl equals either A, B, C, or D. 540 M8049 Cables The three types of cable used to connect the DRV 11-J to a user device are described below. Cable Description Cable Type- Description Max_ Length-- BC02D-XX Flat, 50 wires, shielded connectors (DEC PN 12-11664) on both ends 1.83 m (6 ft) BC08Y-XX Round, 50-pin Berg to 50-pin Berg, 50 wires 1.83 m (6 ft) BC05W-XX Flat, 50 wires, shielded connectors (DEC PN 12-11664) on both ends 7.6 m (25 ft) I/O Signal Specifications All data buffer signals (I/O < 15:00» at the connectors (J 1 and J2) are defined as being asserted (1) high (+ 3 V) and negated (0) low (GND). All protocol signals (DRV11-J ROY, DRV11-J RPLY, USER ROY and USER RPL Y) at the connectors are defined as being asserted (1) low (GND) and negated (0) high (+3 V). I/O Signal Loopback Connections The DRV 11-J signal pin assignments are arranged to permit loopback operation when a BC05W-XX cable is installed with a half-twist connecting J 1-1 to J2-50. With the cable installed in this manner, the proper connections are made to loopback the DRV 11-J protocol signals. -xx in the cable denotes length in feet. For example, a 1.83 m (6 ft) BC02D cable would be ordered as BC02D-06. Maximum cable length is specified as being from DRV 11-J to DRV 11-J. 541 M8049 DRV11-J Loopback Signal Connections J1 Pin No. Port B Port A Signal Signal J2 Pin No . 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 20 22 24 ....... DI/09 50 B I/O 9 ....... D I/O 12 B I/O 12 49 ......... D I/O 11 B I/O 11 48 ....... DI/08 47 B I/O 8 B I/O 14 ....... DI/O 14 46 ....... D I/O 15 B I/O 15 45 ......... DI/O 10 B I/O 10 44 ......... D I/O 13 B I/O 13 43 ....... D1/05 42 Port D B I/O 5 ....... D I/O 7 41 B I/O 7 .......DI/03 40 B I/O 3 ....... D I/O 1 39 B I/O 1 ......DI/02 38 B I/O 2 ....... DI/OO 37 BI/OO .....D1/06 36 B I/O 6 ......D1/04 35 B I/O 4 USER RPLY B + - DRV11-J RPLY D 33 DRV 11-J RDY B--- USER RDY D 31 USER RDY B ------ DRV 11-J RDY D 29 DRV 11-J RPL Y B--' USER RPL Y D 27 27 29 31 33 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 USER RPLY A +-DRV11-J RPLY C 24 DRV 11-J RDY A-+ USER RDY C 22 USER RDY A -+-DRV11-J RDY C 20 DRV 11-J RPL Y A-+ USER RPL Y C 18 .....C I/O 4 16 A I/O 4 ...... C I/O 6 15 A I/O 6 ....... CI/OO 14 A I/O 0 ...... C I/O 2 13 A I/O 2 12 Port C A I/O 1 '-'CI/O 1 ....... CI/03 11 A I/O 3 10 A I/O 7 '-'C1/07 ......... C I/O 5 9 A I/O 5 ....... CI/O 13 8 A I/O 13 ....... C I/O 10 7 A I/O 10 ....... CI/O 15 6 A I/O 15 5 A I/O 14 '-'CI/O 14 ....... C1/08 4 A I/O 8 ...... CI/O 11 3 A I/O 11 2 +-+CI/O 12 A I/O 12 1 A I/O 9 '-'CI/09 Connector pins 17, 19, 21, 23, 25, 26, 28, 30, 32, 34 on J 1 and J2 are grounds. 542 M8186 M8186 KDF11-AX 11/23 MICROCOMPUTER The KDF 11-A is a 16-bit, double-height, multilayered, microcomputer module. The processor (microcomputer) uses the existing LSI-11 bus. The KDF 11 is backward-compatible with existing LSI-11 /2 processors and I/O interfaces. Memory management is included as a standard feature. The KEF 11-A option (not part of a standard system) is a floating point microcode extension chip that mounts to a socket on the KDF 11-A processor module. This chip option can execute the PDP-11 /34 (FP 11) floating point instruction set. These instructions supplement the integer arithmetic instructions (for example, MUL, DIV) in the basic instruction set. Four 40-pin chip sockets mounted on the KDF 11-A module are to accommodate the following chip functions. • Memory Management Unit (MMU) • Spare • Floating point (optional) • Data/control unit (the basic processor) KDF 11 Specifications Identification: M8186 Size: Double-height module Power Requirements: +5 V ± 5% 2.0 A + 12 V ± 5% 0.2 A Bus Loads: AC 2 unit loads DC 1 unit load Environmental: DEC STD 102 Class C 543 M8186 Diagnostic Programs The following diagnostic programs are used with the LSI-11/23 processor, except for the limitations noted. JKDBBO JKDABO CPU trap and EIS diagnostics Memory Management Unit (MMU) Requires KTF 11-A option (21-15542-00/01) installed in IC socket E57. JKDCAO Floating point diagnostic - Part 1 JKDDAO Floating point diagnostic - Part 2 The floating tests require the KEF 11 option to be installed on the board. These diagnostics expect the CPU to be fault free. Therefore, the JKDB?? diagnostic should be run before the floating point diagnostics. NOTE See Appendix A for multimedia assignments. Related Documentation Microcomputer Processor Handbook (EB-18451-20) KDF 11-A Field Maintenance Print Set (MP-00734-00) LSI-11, PDP-11 /23 Reference Card (EH-17898-20) KEF11-A (Floating Point Option Installation) The KEF-11 AA floating point option resides in two MOS/LSI chips contained on one 40-pin hybrid package (57-00001-01). The KEF11-AA requires the memory management chip to be present along with the base MOS/LSI chips, since all of the floating point accumulators and status registers are in the MMU chip. Chapter 10 in the Microcomputer Processor Handbook, EB-18451-20 covers the KEF 11 in detail. Early revision M8186s require an ECO (M8186-S-0007) to accommodate the KEF 11-AA option. Modules at hardware revision A5 (A etch) or C 1 (C etch) and below, require this change. Remove E57 (DEC PN 21-15542-00) Install E57 (DEC PN 21-15542-01) Remove E31 (DEC PN 57-00000-00) Install E21 (DEC PN 57-00000-01) NOTE Mark Rev A6 or C2 on the module handle to indicate the new revision, depending on original etch rev. 544 M8186 After the ECO is installed, install the KEF 11-AA option (57-00001-01) in IC socket position E39. KDF 11 Variations AA -LSI-11 /23 16-bit microcomputer with KTF 11-AA memory management (M8186) AB -KOF 11-AA with KEF 11-AA (floating point option) AC -KOF 11-AA without KTF 11-A GO -KOF11-AC with MXV11-AC and MSV11-CO (32K words) HO -KOF 11-AC with MSV 11-00 (32K words) HF -KOF 11-AA with two MSV 11-00 (64K words) HH -KOF 11-AA with three MSV 11-00 (96K words) HK -KOF 11-AA with four MSV 11-AA (128K words) RE -KOF 11-AA with MXV l1-AC, MSV 11-00 (48K words) and QJV 13-0Z (RT2 V 4.0, license only) RE -KOF 11-AA with MXV 11-AC, two MSV 11-00 (80K words) and QJV 13OZ RJ - KOF 11-AA with MXV 11-AC, three MSV 11-00 (112K words) QJV13-0Z and SE -KOF 11-AA with MXV 11-AC, MSV 11-00 (48K words) and QJ642-0Z (RSX 11-S V 2.2, license only) SG -KOF 11-AA with MXV 11-AC, two MSV 11-00 (80K words) and QJ642OZ SJ - KOF 11-AA with MXV 11-AC, three MSV 11-00 (112K words) QJ642-0Z XA -KOF 11-AA with two MSV 11-EO (64K word) (parity) XB -KOF 11-AA with four MSV 11-EO (128K word) (parity) 545 and M8186 Data/Control (DC302, DC303) Hybrid The data chip (DC302) contains the PDP-11 general registers, the processor status word (PS), several working registers, the arithmetic and logic unit (ALU), and conditional branching logic. The DC302 chip: • performs all arithmetic and logical functions • handles all data and address transfers with the LSI-11 bus (except relocation, which is handled by the MMU) • generates most of the signals used for interchip communication and external system control. Control Chip The control chip (DC303) contains the microprogram sequence logic and 552 words of microprogram storage in programmable logic arrays (PLA) and read-only memory (ROM) arrays. The control chip accesses the appropriate microinstruction in the PLA or ROM and sends it along the MIS to the data and MMU chips for execution. The control chip accesses only its local storage. MMU Chip The MMU chip serves two purposes. • It provides the memory management function. • It provides storage for the KEF 11-AA floating point accumulators and status registers. This chip provides user and kernel mode address relocation of 18 bits. Sixteen-bit virtual addresses are relocated via mapping registers (PARs) to the appropriate 18-bit physical address for the transmission to the external system bus. The MMU chip is controlled by information received on the microinstruction bus (MIS) from both the data chip and the control chip and by several discrete control inputs. The KDF 11-AA can operate without the MMU chip; however, the memory would be limited to 32K words and the floating point registers would not be available. 546 M8186 0--0 W18 Dl ~W19 E57 E48 G~ E39 (;J ::::1- E31 W17 -I -..0 <{a: <{z I-z <{- 1-1- -10- 00 00 u.. 0---<> u o--oW15 W14o---<> 0---<> Wl:l W120--0 0---<> Wl1 Wl 0 0---<> 0---<> W9 W8o---<> O--OW7 W6o---<> o--oW5 IWl I~ W2 0---<> W4 0---0 KDF 11-AA Rev A Jumpers 547 W3 M8186 M8186 (Etch Rev A) Jumper Configurations Jumper Name Function Factory Set W1 Master clock In - enabled In W2 Reserved for DEC use Removed - do not install Out W3 Reserved for DEC use Installed - do not remove In W4 Event line enabled Out - enabled In W5,W6 Power-up mode (. See footnote.) W5 -In W6 - Out W7 Halt/trap option In - traps to 108 on HALT In Out - enters console OOT on HALT W8 Bootstrap address In - powers up to bootstrap address 1730008 In Out - powers up to address specified by W9-W15 W9-W15 User-selectable W9-W 15 correspond to bootstrap address address bits 9 through 15, respectively, in mode 2 In = logic 1 Out = logic 0 Power-Up Mode Selection Mode Name W5 W6 0 PC@24 Console OOT Bootstrap Extended microcode Out In Out In Out Out In In 2 3 548 W9-W15-ln M8186 M8186 (Etch Rev A) Jumper Configurations (Cont) Jumper Name Function W16 Reserved for DEC use Factory-installed; do not remove. In W17 Reserved for DEC use Factory-installed; do not remove. In W18 Reserved for DEC use Factory-installed; do not remove. In Factory Set ~W18 L - E39 <.:I WI «- 1-1- -10.. 00 LL ~ -1 ~O 00 RED JUMPER WI RE 8YPASSES Dl E31 ~I f-z -""'------ «0: «z u o--oW15 W140---0 o---oWl~ W120--0 0---0 W1' Wl00---0 0---0 W9 W80---0 O--OW7 W60--0 o--oW5 W4 0--0 W30--0 W20--0 0 - - 0 W16 0 - - 0 W17 KDF 11-A Rev C Jumpers 549 M8l86 M8186 (Etch Rev C) Jumper Configurations Jumper Name Function Factory Set W1 Master clock In - Enabled In W2 Reserved for DEC use Removed - do not install Out· W3 Reserved for DEC use Installed - do not remove In • W4 Event line enabled Out - enabled In W5, W6 Power-up mode (. • See footnote.) W5 -In W6 - Out W7 Halt/trap option In - traps to 108 on HALT Out Out - enters console OOT on HALT Bootstrap address In - powers up to 1730008 W8 In Out - powers up to address specified by W9-W15 W9-W15 correspond to W9-W15 User-selectable bootstrap address address bits 9 through 15, respectively In = logic 1 Out = logic 0 • Refer to FCO M8186-ROO09 Mode Name W5 W6 0 PC@24 PS@26 Console OOT Bootstrap Extended microcode Out Out In Out In Out In In 1 2 3 550 W9-W15-ln M8186 M8186 (Etch Rev C) Jumper Configurations (Cont) Jumper Name Function Factory Set W16, W17 Reserved for DEC use Factory-installed; do not remove. W16, W17-ln W18 Out = disabled In = enabled In Wake-up circuit Hardware Revision System As other modules have the etch revision level coded into the etch and the circuit schematic revision level coded on the module handle, the M8186 has both codes stamped on the module handle. The revision identifier is a two-field alphanumeric designation. The first field indicates the etch revision. The second field indicates the modifications to this etch. A IDENTIFIES ETCH LEVEl-------Jt 0 t""---IDENTIFIES MODIFICATIONS M8186 Revision Identifiers The M8186 started as hardware revision AO, as shown above; that is, etch revision "A" with no modifications or work. As ECOs were released calling for rework (not a new etch), the hardware revisions were released and the etch revision field was incremented from A to B to C. No etch revision liB" for the M8186 modules was built so the revision level appeared to change from "A" to "C" via ECO no. 4. Etch revision "C" modules had ECO no. 5 incorporated on them before being released, therefore their hardware revision status did not change with ECO no. 5. 551 M8186 The hardware revision history of the M8186 is shown below. NOTE: ALL MODULES SHIPPED ARE AT REVISION A3 OR GREATER NEW ETCH REVISION "C" CREATED. NO REVISION "6" MODULES WERE BUILT CURRENT STATUS AS OF THIS WRITING RELEASE "AD" REWORK ECO NO 1 "Al" REWORK ECO NO 2 "A2" REWORK ECO NO 3 "A3" RELAYOUT ECO NO 4 ~ ~ ~ j~r REWORK ECO NO 5 "A4" "CO" REWORK ECO NO 6 "A5" ~ "Cl" REWORK ECO NO 7 "A6" ~ "C2" REWORK ECO NO 8 "A6" REWORK ECO NO 9 "A7" ~ ~ ~ ~ ~ "C2" ~ "C3" M8186 ECO Summary 552 NOTE: THE RELAYOUT INCORPORATED THE CHANGES FOR ECO NO 5 NOTE: THIS WAS A DOCUMENTATION CHANGE ONLY M8186 11/23 (M8186) ECO Summary The following table details the ECOs issued since the first M8186 shipment. These ECOs are coded "M8186-MlOOOX", where "X" is the ECO number shown below. ECO No. Problem Quick Verify 4 Too many wires and etch cuts, new etch needed. Note that the jumper locations change for etch revision "C". Module handle will be stamped "C?" (where "?" refers to the CS revision). 5 Possible parity errors when using parity memories (MSV 11-E, etc.) Check for etch cut to E7 pins 16 and 18. NOTE Implementation of this ECO impacts configurations. This ECO is discussed in detail below. 6 The internal wake-up circuit defeats the sequencing provided by standard DEC power supplies. This ECO should be installed when the M8186 is used with same. Red jumper wire is installed in parallel with 01. 7 CTl/DAT hybrid (57-00000-00) and MMU IC (21-15542-00) were not compatible with KEF 11-AA floating point option. The FP registers in the MMU were inaccessible, and the CTl/DAT data path caused intermittent errors in floating point instructions. CTl/DAT should be 57-00000-01 and MMU should be 21-15542-01 for floating point compatibility. Coordinate with ECO M8186-0009. 8 MMU (21-15542-01) was included as part of the M8186 module. It should have been specified as an option that could have added to the MMU from the M8186. ECO KDF 11 A-OOO 1 adds it back in at the option level (KDF11-AB, KDF11-AA). This is a documentation change only. Modules in systems may or may not have MMU, depending upon which option they represent. Spares, however, are ordered as modules and will not have MMUs. MMUs must be ordered separately. 553 M8l86 fCO No. Problem 9 1. No jumper table in print set (documentation change only). 1. Prints contain a jumper table. 2. Metal oscillator may short to adjacent components. 2. Oscillator has nylon spacer. Manufacturing change only. Do not retrofit in field! 3. Possibility of worst case MMU timing violations. Change configuration of W2 and W3 to adjust timing. This ECO must be installed: 3. Module will have W2 removed and W3 in. On etch Rev "A" modules, W3 is installed by soldering a jumper wire from E2 pin 5 to E2 pin 15. Quick Verify a. when ECO M8186-0007 is put in b. when a microcode option (i. e., KEF 11) is installed c. when a 40-pin IC (CTl/ OAT, MMU or KEF11) is replaced d. whenever unexplained system crashes occur. ECO No.5 A circuit was included in the KDF 11-A to compensate for a design limitation in the MSV 11-C and MRV 11-C. That is, these devices do not use BBS7 to deselect themselves. It is this limitation that causes the requirement to jumper-deselect memory in the 28K-32K range on lSI-11s; otherwise the MSV 11-C would respond to peripheral addresses. Unfortunately, the parity problem with MSV 11-E could not be fixed except by disabling this circuit. As a result, after this ECO is installed (hardware revision "A4" and above, and all etch revision "C"), the MSV11-C cannot be configured in the 28K - 32K (word) or in the 124K -128K (word) range. MRV 11-C cannot be configured in the 28K-32K (word) range on mapped systems when used in the "direct" or "window" addressed modes. On unmapped systems (11/03 and KDF 11-AC) it may be configured in the I/O page. 554 M9400 M9400-XX REV11, TEV11, AND BCV1X Bus Loads Amps Cables +5 + 12 AC DC M9400-YA (REV11-A) 1.64 (2.24 max.) 0 1.0 M9400-YB (TEV 11) 0.54 (0.70 max.) 0 M9400-YC (REV 11-C) 1.0 (1.85 max.) 0 2.21 1.0 M9400-YO (BCV 1A) 0 0 0 0 (2) BC05 L M9400-YE (BCV 1B) 0.29 0 0 0 (2) BC05 L 1.64 0 2.21 1.0 2.21 1.0 M9400-YF (REV 11-F) M9400-YH (REV 11-H) M9400-Y J (REV 11-J) (2) BC05 L M9400-YK (REV 11-K) M9400-YL (REV 11-L) M9400- YM (REV 11-M) M9400-YN (REV 11-N) 1.64 0 2.21 Related Documentation REV 11-A, C Field Maintenance Print Set (MP00073) REV 11-H Field Maintenance Print Set (MP00331) TEV 11 Field Maintenance Print Set (MP00074) Microcomputer Interfaces Handbook (EB-20175-20) 555 1.0 M9400 o o o 0 c W2 DMA REFRESH ENABLE I CONNECTORS PRESENT ONLY ON YO, YE, YJ, AND YK W4 BOOTSTRAP ROM ENABLE I DOD 0 E29 E25 E22 E19 W3 (ALWAYS INSTALLED) I M9400 Jumper Locations W 1: Installed to enable BDMG arbitration. Installed on -VB, -YO, and -YE modules. Not installed on -VA, -ye, -YF, -YH, -YK, and -YJ modules. W2: Install to enable DMA refresh. W3: Always installed. W4: Install to enable bootstrap ROMs. If REV 11 refresh is enabled, the memory electrically farthest from the REV11 must reply to refresh. Also, processor refresh must be disabled. 556 M9400 NOTES 1. If no memory replies to REV 11 refresh, the REV 11 may hang the processor. The problem will appear to be a nonfunctioning CPU. 2. If the REV11 is not up to ECO no. 5 level or greater, the same symptoms may occur if a DRV 11 is present that has an external capacitor to extend NEW DATA READY to greater than 1.8 J,LS. Ji/#MA "oQ: "oQ:! ~"'~'" ~ #' "oQ: ~ ~ II "'~!#' ~ ~ ~ ~ 8 # c:- $ VA· YB c:- $ x " X X YE YF* X YH* X YJ* YK* X X X X X X X ~ ~ ~'" ~ $ ~ I I I REVll·A I R I R TEVll R I I I REVll·C X I R I R BCV1A·XX X I R I R BCV1B·XX R I I I REVll·F R I I I REVll·H ** R I I I REVll·J R I I I REVll·K ** X YO ~ oQ: R x X YC* ~ X ;y tq $;:- ",'" ,f R" .# ~:~:~~ATI ON !rQ: ,l o~ l x I ~ x = FEATURE PRESENT I = JUMPER INSTALLED R = JUMPER REMOVED * FACTORY·SET POTENTIOMETER ** REMOTE BOOT M9400 Jumper Variations The jumper states indicated in the preceding figure are as they are shipped from the factory. BCV options also include M9401 backplane connectors and BC05L expansion cables. Certain rules for cable lengths and module locations must be observed. Refer to the "Systems Configurations" section for these configuration rules. 557 M9400 REV 11 ROM Program Commands Command Function 00 OOT (Halt). This allows the operator to examine and/or alter memory and register locations via the console device. Control can be returned to the REV 11 program by entering the ODT P (proceed) command if the PC has not been altered, and the console device will display the $ prompt character. If the PC has been altered, the operator can start program execution by entering the starting address 165006 and the G (go) commands as follows. @ 165006G $ The processor responds by displaying the $ prompt character on a new line and another REV 11 command can be entered. XM<CR> Memory Diagnostic program. After successfully completing the diagnostic, the prompt character ($) is displayed on the console device. Errors are indicated by the following displays on the console device. 1. 173732 @ This is an address test error. The expected (normal) data is in R3 and the invalid data is in the memory location pointed to by R2. If desired, continue diagnostic program execution by entering the ODT P command. 2. 173756 @ This is a data test error. The expected (normal) data is stored in R3 and the invalid data is in the memory location pointed to by R2. If desired, continue diagnostic program execution by entering the ODT P command. 3. 000010 @ A timeout trap has occurred in testing memory locations outside of the first (lowest) 4K memory. 558 M9400 REV 11 ROM Program Commands (Cont) Command Function 4. nnnnnn @ A timeout trap has occurred in testing memory locations within the first 4K memory. The nnnnnn displayed is an indeterminate number. The actual memory test consists of an address test and a data test. The address test first writes all memory locations with addresses; it then reads and verifies the addresses. The data test consists of two parts. An "all 1s" word is first walked through all memory locations, which are initially o. The second part consists of walking an all Os word through all memory locations which are all 1s. XC<CR> Processor Diagnostic program. This is a memory-modifying instruction test. Successful execution of the diagnostic program results in the prompt character ($) being displayed on the console device. Errors are indicated by the following. 1. The program halts when an instruction sequence is not correctly executed. 2. The program halts in the trap vector area for various traps. NOTE When a halt occurs, the console ODT M command can be used to determine how the halt mode was invoked. When the system fails to successfully execute the above diagnostics, maintenance diagnostic programs should be used to thoroughly test processor (and memory) functions. DX<CR> or RXV 11 floppy disk system bootstrap. Entering the DX <CR> command starts the memory-modifying CPU instruction test DXn<CR> and memory test execution (see the XC and XM commands). Successful test execution results in execution of the bootstrap program for disk drive 0, the system disk. Otherwise, specify the drive number (n) as 0 (drive 0) or 1 (drive 1). 559 M9400 REV 11 ROM Program Commands (Cont) Command Function Floppy disk bootstrap errors are: 1. The program halts and the console device displays the following. 165316 @ This indicates that the device done flag in the RXV 11 interface was not set within the required time (approximately 1.3 seconds). The bootstrap can be restarted by entering the P command; the $ is then displayed on the console device and the bootstrap command can be entered. 2. The program halts and the console displays the following. 165644 @ This indicates that a bootstrap error occurred. The RXV 11's error register contents are stored in R2. By examining the contents of R2 and using the information contained in the RXV11 User's Manual, the exact nature of the error can be determined. Examine the contents of R2 (nnnnnn) as follows. @ R2/nnnnnn<CR> @P $ After examining R2, the bootstrap can be restarted by the P command; enter the desired bootstrap command immediately after the $ prompt character. 3. The program halts in the trap vector for traps; a timeout trap returns the program to the $ prompt character. If a timeout trap occurs, first check for proper system cable connections and device interface module installation. Then, attempt to bootstrap the system by again entering the desired bootstrap command. 560 M9400 REV 11 ROM Program Commands (Cont) Command Function OK <CR> or DKn<CR> Disk Drive System Bootstrap. Entering the OK command starts the memory-modifying CPU instruction test and memory test execution (see the XC and XM commands). Successful test execution results in execution of the bootstrap program for disk drive 0, the system disk. Otherwise, specify the drive number n as (drive 0), 1 (drive 1), or 2 (drive 2). ° Disk bootstrap errors are: 1. The program halts and the console device displays the following. 165724 @ This indicates that the device done flag in the RKF 11-0 interface was not set within the required time (approximately 1.3 seconds). The bootstrap can be started by entering the P command; the $ is then displayed on the terminal and the bootstrap command can be entered. 2. The program halts and the console then displays the following. 165644 @ This indicates that a bootstrap error occurred. The RKV 11-0 error register contents are stored in R2. By examining the contents of R2 and using the information contained in the RKV11-D User's Guide, EK-RKV11-0P, the nature of the error can be determined. Examine the contents of R2 (nnnnnn) as follows: @R2/nnnnn<CR> @P $ After examining R2, the bootstrap can be restarted by the P command; enter the desired bootstrap command immediately after the $ prompt character. 561 M9400 REV11 ROM Program Commands (Cont) Command Function 3. AL<CR> The program halts in the trap vector for traps; a timeout trap returns the program to the $ prompt character. If a timeout trap occurs, first check for proper system cable connections and device interface module installation. Then, attempt to bootstrap the system by again entering the desired bootstrap command. Absolute Loader program, normal (absolute address) loading operation. Entering AL <CR> specifies that a paper tape is to be loaded via the console device (CSR address = 177560). However, another device can be specified by entering the appropriate CSR address. For example, to load paper tapes in absolute loader format via a device whose CSR address is 177550, enter the following command. $ AL 177550<CR> The program responds by first executing the memory-modifying CPU instruction test and memory test (refer to the XC and XM commands). Successful test execution results in execution of the Absolute Loader program. A successful program load is indicated when the console device displays the following. 165625 @ The loaded program automatically starts execution, or Absolute Loader errors are: 1. Checksum error, with the program halting and producing the following display. 165534 @ 2. Program halts in the trap vector area for traps other than a timeout trap. 3. Timeout trap occurs, causing the display of $ on a new line on the console device. 562 M9400 REV11 ROM Program Commands (Cont) Command Function AR<CR> Absolute Loader program, relocated loading operation. When this command is entered, the memory-modifying CPU instruction test and memory test are automatically first executed (refer to the XC and XM commands), followed by the Absolute Loader program. Successful execution of the tests results in the program halting with the following console display. 165412 @ The operator must then enter the appropriate "software switch register" contents in R4. To select relocated loading, which uses an address (bias) contained in the software switch register, enter the following commands. @ R4/ xxxxxx nnnnnn<CR> @P The value nnnnnn is a relocation value selected by the operator as directed in the PDP-II Paper Tape Software Handbook, 11-XPTSA-BO. Observe that the least significant lin" value entered must be an odd number; this sets the software switch register (R4) bit 0 to a logical 1, selecting the relocated loading mode. Note that the program being loaded must be in Position Independent Code (PIC) format for relocated loading. When large programs are contained on more than one tape, the program halts at the end of the first tape. Install the second tape in the reader and enter a "1" in R4 using the OOT command shown below; resume loading by entering the P command. @ R4/xxxxxx 1<CR> @P The six octal digits (xxxxxx) are the present contents of R4. Entering a value of 1 selects relocated loading for the next program tape, starting at the address following the end of the previous load operation. The P command allows the Absolute Loader program execution to continue the loading process once the software switch register value has been entered. 563 M9400 REV 11 ROM Program Commands (Cont) Command Function A successful program load is indicated when the loaded program automatically starts execution, or the console device displays. 165626 @ Absolute Loader errors are as described for the AL command. 564 RK05 RK05 RK05 Disk Drive The RK05-J disk drive uses a removable disk cartridge and the RK05-F uses a fixed, dual-density disk cartridge. Both drives are interfaced by the RKV11-D option. The RKV11-D is set at address 177400 and vector 220. Applicable diagnostic programs are found in Appendix A. Related Documentation RKV 11-D Field Maintenance Print Set (MP-00223-00) RK05-J Field Maintenance Print Set (MP-ORK05-0J) RK05-F Field Maintenance Print Set (MP-ORK05-0F) RKVll-D User's Guide (EK-RKV11-0P) Microcomputer Interfaces Handbook (EB-20 175-20) RK05 Disk Drive User's Guide (EK-ORK05-0P) RK05/05J/05F Maintenance Manual (EK-RK5JF-MM) RK05 Exercisor Maintenance Manual (EK-RK05X-MM) I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1I~1~lIl il l l~ l~ RK05 Disk Drive 565 RK05 Controls and Indicators for the RK05, RK05-J, and RK05-F Controls and Indicators Description RUN/LOAD (Rocker Switch) Placing this switch in the RUN position (provided that all interlocks are safe): a. b. c. d. locks the drive front door accelerates the disk to operating speed loads the read/write heads lights the RDY indicator. Placing this switch in the LOAD position: a. b. c. d. unloads the read/write heads stops the disk rotation unlocks the drive front door when the disk has stopped lights the LOAD indicator. CAUTION Do not switch to the LOAD position during a write operation; this results in erroneous data being recorded. WT PROT (Rocker Switch Spring-Loaded Off) Placing this momentary contact switch in the PROT position lights the WT PROT indicator and prevents a write operation; it also turns off the FAULT indicator, if that is lit. Depressing this switch in the WT PROT position a second time turns off the WT PROT indicator and allows a write operation. PWR (Indicator) Lights when operating power is present. Goes off when operating power is removed. RDY (Indicator) Lights when: a. the disk is rotating at the correct operating speed b. the heads are loaded c. no other conditions are present (all interlocks safe) to prevent a seek, read, or write operation. Goes off when the RUN/LOAD switch is set to LOAD. 566 RK05 Controls and Indicators for the RKOS, RKOS-J, and RKOS-F (Cont) Controls and Indicators Description ON CYL (Indicator) Lights when: a. the drive is in the ready condition b. a seek or restore operation is not being performed c. the read/write heads are positioned and settled. Goes off during a seek or restore operation. FAUL T (Indicator) Lights when: a. erase or write current is present without a write gate b. the linear positioner transducer lamp is inoperative. Goes off when the WT PROT switch is pressed, or when the drive is recycled through a run/load sequence. WT PROT (Indicator) Lights when: a. b. the WT PROT switch is pressed the operating system sends a WRITE PROTECT command. Goes off when the WT PROT switch is pressed a second time, or when the drive is recycled through a run/load sequence. LOAD (Indicator) Lights when the read/write heads are fully retracted and the spindle has stopped rotating. WT (Indicator) Lights when a write operation occurs. Goes off when the write operation terminates. RD (Indicator) Lights when a read operation occurs. Goes off when the read operation terminates. 567 RK05 Performance Specifications Storage Medium Type Single-disk magnetic cartridge (RK05, RK05J - removable; RK05F - nonremovable) Disk Diameter 5.51 cm (14 inches) Magnetic Heads Number 2 Bit Transfer Transfer Code Transfer Rate Double frequency, NRZ recording 1.44 m bit/s Electrical Requirements Voltage Power Starting Current 115/230 Vac @ 50/60 Hz ± .05 Hz 250 VA Power only: 1.8 A Start spindle: 10 A (for 2 seconds) Model Designation RK05-AA, RK05J-AA, RK05F-AA, RK05F-FA 95 - 130 Vac @ 60 ± 0.5 Hz RK05-AB, RK05J-AB, RK05F-AB, RK05F-FB 290 - 260 Vac @ 60 ± 0.5 Hz RK05-BA, RK05J-BA, RK05F-AC, RK05F-FC 95 - 130 Vac @ 50 ± 0.5 Hz RK05-BB, RK05J-BB, RK05F-AD, RK05F-FD 190 - 260 Vac @ 50 ± 0.5 Hz Dimensions and Weight Width: Depth: Height: Weight: 48 cm (19 in) 67 cm (26.5 in) 27 cm (10.5 in) 50 kg (110 Ib) 568 RK05 Unit Selection An RK05 disk drive may be configured to respond to a desired unit designation by selecting the appropriate setting on a rotary switch. The rotary switch is located on the second module in the card cage. The circuit cards are located behind the prefilter, and may be accessed by removing the rear cover panel on the bottom side of the disk drive unit. In the RK05-J, the rotary switch is on the M7700 module. In the RK05-F it is on the M7680. M7700 OR M7680 ~ r-- / "' "- ~ / "-- M7700 or M7680 Placement Bootstrap Program for RK05 If an RK05 is used in a system that has no hardware bootstrap module, the disk drive may be booted by entering the following program manually. @RO/OOOOOO OnOOOO<CR>· @R 1/000000 177404<CR> @1000/000000 000005<LF> 001002/000000 010061 <LF> 001004/000000 000006<LF> 001006/000000 012761 <LF> 001010/000000 177400<LF> 001012/000000000002<LF> 001014/000000 012711 <LF> 001016/000000 000005<LF> 001020/000000 105711 <LF> 001022/000000 100376<LF> 001024/000000 005007 <CR> @1000G • n = 0 for drive 0; 2 for drive 1; and 4 for drive 2. 569 RK05 o 0 00 DISK DRIVE UNIT NUMBER SELECTOR SWITCH Controller Switches 570 RL01/02 RL01/RL02 RL01/RL02 Disk Drive The RLO 1 is a 5,000,000 byte disk drive that uses a modified, removable, 5440-style cartridge (RL01K-DC). The RL02 is a dual-density version of the RLO 1. The RL02 uses an RL02K-DC cartridge. Both the RLO 1 and RL02 use the RL V 11 interface module. Up to four drives of either type in any combination can be connected to an RL V 11 interface. The RL V 11 is normally configured for a bus address of 77440X octal with a vector address of 160 octal. For more in-depth information, refer to the RL V 11 (M80 13/80 14) section. Additional information can be found in the following manuals. RLOI/RL02 Disk Drive Technical Manual (EK-RL012-TM) RL VII Technical Description (EK-RLV 11-TD) RLO 1/RL02 Pocket Service Guide (EK-RLO 12-PG) RLOI/RL02 Disk Subsystem User's Guide (EK-RL012-UG) RLO 1 Illustrated Parts Breakdown (EK-ORLO 1-IP) RL02 Illustrated Parts Breakdown (EK-ORL02-IP) RLO 1 Field Maintenance Print Set (MP-00527 -00) RL02 Field Maintenance Print Set (MP-00698-00) RL V 11 Field Maintenance Print Set (MP-00635-00) Microcomputer Interfaces Handbook (EB-20 175-20) SpeCifications RLO 1 /RL02 Medium Type: Single platter, top-loading cartridge (similar to IBM 5440). Embedded servo information. Capacity: RLO 1K-DC = 5.2 Mb RL02K-DC = 10.4 Mb Cylinders: RL01 = 256 RL02 = 512 Sectors: 40 Heads: 2 571 RL01/02 (A) LOAD SWITCH AND INDICATOR (B) UNIT SELECT PLUG/READY LIGHT (D) WRITE PROTECT AND SWITCH INDICATOR RLO 1jRL02 Controls and Indicators Data Transfer MFM (Miller coding) recording; 244 ns cell time; 4.1 megabytes/s (4.9 J,Ls/word). RL01/RL02 Bootstrap Ensure that the heads are over cylinder 0 and head 0 is selected by releasing the LOAD switch, waiting for the LOAD indicator to light, then depressing the LOAD switch. After the drive is ready, initialize the controller with a system initialize. Perform a bit status clear. Load the following program into memory. LOC Contents Comments 10000 10002 10004 10006 012737 000014 174400 000001 Load CSR Wait Start the program at 10000 and allow it to run for a few seconds, halt the program and restart at 00000. 572 RL01/02 RLO 1 /RL02 Controls and Indicators Switches Function Power ON/OFF Circuit Breaker (Located in the rear of the drive) In the OFF position, ac power is removed from the drive. (A) LOAD This is a PUSH/PUSH alternating action switch. When depressed, the RL01/RL02 begins a "cycle up" sequence, provided that: In the ON position, ac power is supplied to the drive. • • • • • • the RLO 1/RL02K cartridge is installed the cartridge cover is in place the access door is closed all ac and dc voltages are within spec the R/W heads are retracted the brushes are in the "home" position. When released, the RL01/RL02 will begin a "cycle down" sequence. (B) UNIT SELECT PLUG This is a cam-operated switch that is activated by inserting a numbered, cammed button. The switch contacts are binary encoded so that the drive assumes the logical unit number that is printed on the button. (D) WRITE PROTECT This is an alternating action PUSH/PUSH switch. When depressed, the drive assumes a write protect status (during a write operation). When released, the drive is no longer write protected. 573 RL01/02 RL01/RL02 Controls and Indicators (Cont) Indicators Function (A) LOAD (Yellow) Indicates that the drive is ready to have a cartridge loaded (or unloaded). The LOAD indicator will light when: • • • the spindle is stopped the R/W heads are "home" the brushes are "home." (8) READY (White) When lit, indicates a "drive ready" condition; i.e., the heads are loaded and detented. (C) FAULT (Red) Indicates when one of the following has occurred. • • • • • • • drive select error seek timeout error (1.5 second) write current in heads during "sector time" loss of system clock from RL V 11 write data error (no transitions) spin error (over speed or 40 sec timeout) write gate error (attempting to write when not ready, when write protected, or during sector time) (D) WRITE PROTECT Indicates that drive is write protected. That is, write (Yellow) operations to the cartridge will be inhibited (and the FAULT indicator will light). 574 RX01 RX01 RX01 Floppy Disk Drive The RXO 1 floppy disk drive is part of the RXV 11 floppy disk system, and is interfaced by the RXV 11 interface module (M7946). The disk system uses address 177170 and vector 264 for the first option, and address 177174 and vector 270 for a second option. [llmmll~lllllllli:lilil~IIIIIIIII~11 RXO 1 Floppy Disk Model Designations RXV 11-AA Single Drive System, 115 V /60 Hz RXV 11-AC Single Drive System, 115 V /50 Hz RXV 11-AD Single Drive System, 230 V /50 Hz RXV 11-BA Dual Drive System, 115 V /60 Hz RXV 11-BC Dual Drive System, 115 V /50 Hz RXV 11-BD Dual Drive System, 230 V /50 Hz 575 RX01 Related Documentation RXV11 User's Manual (EK-RXV11-00) RXO 1/RXB/RX11 Floppy Disk System Maintenance Manual (EK-RXO 1-MM) RXV 11 Field Maintenance Print Set (MP-00024-00) RXO 1 Field Maintenance Print Set (MP-00296-00) RXO 1/RX02 Reference Card (EK-RXO 1-RC) Microcomputer Interfaces Handbook (EB-20175-20) NOTE 50 Hz versions are available in voltages of 105, 115, 220, and 240 Vac by field-pluggable conversion. Refer to the RX01/RXB/RX11 Floppy Disk System Maintenance Manual for complete input power modification details. AC Power The RXV 11 floppy disk system is available in the following three ac voltage/model configurations. Models Voltage/Frequency RXV11-AA, -BA RXV11-AC, -BC RXV11-AD, -BD 100 Vac-132 Vac, 60 Hz 100 Vac-132 Vac, 50 Hz 180 Vac-264 Vac, 50 Hz, in one of two voltage ranges. The actual voltage range is user-selected by installing the appropriate power harness during system installation, as follows. Voltage Range Power Harness PN 180-240 200-264 70-10696-04 70-10696-03 Power Consumption RX01 RXV 11 interface (M7946) Power input (ac) 3 A at 24 V (dual), 75 W; 5 A at 5 V, 25 W Not more than 1.5 A at 5 Vdc 4Aat 115Vac 2 A at 230 Vac 576 RX01 Bootstraps for Manual Entry Full Length Version Abbreviated Version (Drive 0 Only) @1000/000000 12702<LF> 001002/0000001002n7<LF>* 001004/000000 12701<LF> 001006/000000 177170<LF> 001010/000000 130211<LF> 001012/000000 1776<LF> 001014/000000 112703<LF> 001016/0000007<LF> 001020/000000 101 OO<LF> 001022/000000 10220<LF> 001024/000000402<LF> 001026/000000 1271 O<LF> 001030/000000 1 <LF> 001032/000000 6203<LF> 001034/000000 103402<LF> 001036/000000 112711 <LF> 001040/000000 111 023<LF> 001042/000000 32011 <LF> 001044/000000 1776<LF> 001046/000000 100756<LF> 001050/000000 103766<LF> 001052/000000 105711 <LF> 001054/000000 100771 <LF> 001056/0000005000<LF> 001060/000000 2271 O<LF> 001062/000000 240<LF> 001064/000000 1347<LF 001066/000000 122702<LF> 001070/000000 247 <LF> 001072/000000 5500<LF> 001074/0000005007<CR> @1000/000000 5000<LF> 001002/000000 12701<LF> 001004/000000 177170<LF> 001006/000000 105711 <LF> 001010/000000 1776<LF> 001012/000000 12711 <LF> 001014/000000 3<LF> 001016/000000 5711<LF> 001020/000000 1776<LF> 001022/000000 100405<LF> 001024/000000105711<LF> 001026/000000 100004<LF> 001030/000000 116120<LF> 001032/0000002<LF> 001034/000000 770<LF> 001036/000000 O<LF> 001040/0000005007<CR> *n = 4 for unit 0 n = 6 for unit 1 <LF> = Line Feed <CR> = Carriage Return Starting address = 1000 577 RX02 RX02 RX02 Floppy Disk Drive The RX02 is part of the RXV11-XX floppy disk system. The RXV21-8X options use the RX02 in double-density mode with the RXV21 (M8029) interface module. The RXV21-DX options use the RX02 in single-density mode with the RXV 11 (M7946) interface module. mRtImo RX02 Front View of the Floppy Disk System The density mode of the RX02 is selected by switches on the M7744 controller module. This module is located in the RX02 floppy disk drive. The following switch settings define the mode of the RX02. Controller Configuration Switch Settings (Located on M7744 Module) Interface 51-1 51-2 RX211 jRXV21 RX8EjRX 11 jRXV 11 RX28 OFF ON OFF ON OFF OFF NOTE The subject of the RX02 as used in a PDP-8 system is beyond the scope of this document. Detailed configuration and diagnostic information is contained in this manual. Refer to the section covering the applicable interface (M7946 or M8029). 578 RX02 Related Documentation RX02 Floppy Disk System User's Guide (EK-ORX02-UG) RXO 1/RX02 Reference Card (EK-RX 102-RC) Microcomputer Interface Handbook (EK-20175-20) RX02 Print Set (MP-00629-00) Module Designations RXV21 -DA -DC -DD M7946 M7946 M7946 RX02-DA RX02-DC RX02-DD 115 V, 60 Hz 115 V, 50 Hz 230 V, 50 Hz -BA -BC -BD M8029 M8024 M8027 RX02-BA RX02-BC RX02-BD 115 V, 60 Hz 115 V, 50 Hz 230 V, 50 Hz Power Requirements The RX02 is designed to use either a 60 Hz Vac or a 50 Hz power source. The 60 Hz version will operate from 90 Vac-128 Vac, without modifications, and will use less than 4 A operating. The 50 Hz version will operate within four voltage ratings and will require field verification/modification to ensure that the correct voltage option is selected. The voltage ranges of 90 Vac-120 Vac and 184 Vac-240 Vac will use less than 4 A operating. The voltage ranges of 100 Vac-128 Vac and 200 Vac-256 Vac will use less than 2 A. Both versions of the RX02 will be required to receive the input power from an ac source (e.g., 861 power control) that is controlled by the system's power switch. Input Power Modification Requirements The 60 Hz version of the RX02 uses the H771-A power supply and will operate on 90 Vac-128 Vac, without modification. To convert to operate on a 50 Hz power source in the field, the H771-A supply must be replaced with an H771-C or -D and the drive motor belt and drive motor pulley must be replaced. The H771-C operates on a 90 Vac-120 Vac or 100 Vac-128 Vac power source. The H771-D operates on a 184 Vac-240 Vac or 200 Vac-256 Vac power source. To convert the H771-C to the higher voltage ranges or the H771-D to the lower voltage ranges, the power harness and circuit breaker must be changed. The appropriate jumper and circuit breaker are shown in the following figure. 579 RX02 JUMPER P1 SHIPPING RESTRAINT (RED) VOLTAGE (VAC) JUMPER CIRCUIT BREAKER 90-120 100-128 184-240 200-256 70-10696-02 70-10696-01 70-10696-04 70- 10696-03 3_5 A, 12-12301-01 3.5 A, 12-12301-01 1.75 A, 12-12301-00 1.75 A, 12-12301-00 RX02 (Rear View) Bootstrap for Manual Entry (ODT) RX02/RXV 11 (M7946) @1000/XXXXXX 1002/XXXXXX 1004/XXXXXX 1006/XXXXXX 1010/XXXXXX 1012/XXXXXX 1014/XXXXXX 1016/XXXXXX 1020/XXXXXX 1022/XXXXXX 1024/XXXXXX 1026/XXXXXX 1030/XXXXXX 1032/XXXXXX 1034/XXXXXX 1036/XXXXXX 1040/XXXXXX 1042/XXXXXX @1000G 5000<LF> 12701<LF> 177170<LF> 105711<LF> 1776<LF> 12711<LF> 3<LF> 5711<LF> 1776<LF> 100405<LF> 105711 <LF> 1000004<LF> 116120<LF> 2<LF> 770<LF> O<LF> 5000<LF> 110<CR> <LF> = Line Feed. <CR> = Carriage Return. XXXXXX = Original contents of location opened. 580 RX02 RX02/RXV21 (M8029) @2000/XXXXXX 2002/XXXXXX 2004/XXXXXX 2006/XXXXXX 2010/XXXXXX 2012/XXXXXX 2014/XXXXXX 2016/XXXXXX 2020/XXXXXX 2022/XXXXXX 2024/XXXXXX 2026/XXXXXX 2030/XXXXXX 2032/XXXXXX 2034/XXXXXX 2036/XXXXXX 2040/XXXXXX 2042/XXXXXX 2044/XXXXXX 2046/XXXXXX 2050/XXXXXX 2052/XXXXXX 2054/XXXXXX 2056/XXXXXX 2060/XXXXXX 2062/XXXXXX 2064/XXXXXX 2066/XXXXXX 2070/XXXXXX 2072/XXXXXX 2074/XXXXXX 2076/XXXXXX 2100/XXXXXX 2102/XXXXXX 2104/XXXXXX 2106/XXXXXX 2110/XXXXXX 2112/XXXXXX 2114/XXXXXX 2116/XXXXXX 2120/XXXXXX 2122/XXXXXX 2124/XXXXXX 12701<LF> 177170<LF> 12700<LF> 100240<LF> 5002<LF> 12705<LF> 200<LF> 12904<LF> 401 <LF> 12703<LF> 177172<LF> 10011 <LF> 1776<LF> 100440<LF> 12711<LF> 407<LF> 10011<LF> 1776<LF> 100433<LF> 110413<LF> 304<LF> 30011 <LF> 1776<LF> 110413<LF> 304<LF> 30011 <LF> 1776<LF> 100422<LF> 12711<LF> 408<LF> 10011 <LF> 1776<LF> 100415<LF> 10513<LF> 30011 <LF> 1776<LF> 100411 <LF> 10213<LF> 6052<LF> 60502<LF> 122474<LF> 120427<LF> 7<LF> 581 RX02 RX02/RXV21 {M8029){Con~ 2126/XXXXXX 2130/XXXXXX 2132/XXXXXX 2134/XXXXXX @2000G 3737<LF> 5000<LF> 5007<LF> O<CR> 582 APPENDIX A DIAGNOSTIC MEDIA AVAILABILITY Module Number Option Name M7264-XX KD11-F/ KD11-H/ KD11-HW (LSI-11) Diagnostic and DEC/X11 Diagnostic and File Names Notes DEC/X11 Module Titles VKAB??BI? VKAC??BI? 5 VKAD??BI? 5 VKAH??BI? VKAI??BI? 6 VKAJ??BI? 6 VKAL??BI? 5 XCPA??OBJ XCPB??OBJ (Listing) (Binary PT) (Listing) LSI-11 EIS Instruction Set Test (Binary PT) (Listing) LSI-11 FIS Instruction Set Test (Binary PT) (Listing) LSI-11 Traps Test (Binary PT) (Listing) LSI-11 4K System Exerciser (Binary PT) (Listing) LSI-11 DIS Move & String Test (Binary PT) (Listing) LSI-11 DIS Decimal Instructions (Binary PT) (Listing) LSI-11 Trap Test (30K + FIS) (Binary PT) DEC/X11 Processor Test Module (Listing) (Binary PT) (Listing) DEC/X 11 EIS Exerciser Module (Binary PT) LSI-11 Basic Instruction Test VKAA??BI? Listing and Paper Tape PNs AC-8186C-MC AK-8188C-MC AC-8190A-MC AK-8192A-MC AC-8194C-MC AK-8197C-MC AC-8198C-MC AK-8-IC-MC AC-8210A-MC AK-8212A-MC AC-8214A-MC AK-8217A-MC AC-8218A-MC AK-8221A-MC AC-FO 12A-MC AK-F014A-MC AC-E664G-MC AK-E665G-MC EC-E667 J-MC AK-E668J-MC R R R R R X X L L 0 0 5 1 2 0 1 2 0 K 0 4 13 18 19 20 4 13 18 19 20 4 13 18 19 20 4 13 18 19 20 4 13 18 1920 4 13 18 19 20 4 13 18 19 20 4 13 18 19 20 1 14 18 1920 Module Number Option Name Diagnostic and DECjX11 Diagnostic and File Names Notes DECjX 11 Module Titles M7269 RKV11-D ZRKH??BI? 7,8 ZRKI??BI? 7 ZRKJ??BI? 7 ZRKK??BI? 7,9 ZRKL??BI? 7,10 XRKA??OBJ 7 M7270 KD11-HA VKAA??BI? VKAB??BI? VKAC??BI? 5 VKAD??BI? 5 VKAH??BI? XCPA??OBJ XCPB??OBJ RK 11 jRK05 Performance Exerciser RK 11 Utility Package Listing and Paper Tape PNs (Listing) (Binary PT) (Listing) (Binary PT) (Listing) RK11 Basic Logic Test No.1 (Binary PT) RK 11 Basic Logic Test No.2 (Listing) (Binary PT) RK11jRK05 Dynamic Test (Listing) (Binary PT) DECjX 11 RK 11 Exerciser Module (Listing) (Binary PT) AC-9232G-MC AK-9235G-MC AC-9236F-MC AC-9239F-MC AC-9240E-MC AK-9243E-MC AC-9244F-MC AK-9247F-M1 AC-9248E-MC AK-9251E-MC AC-E676G-MC AK-E677G-MC LSI-11 Basic Instruction Test AC-8186C-MC AK-8188C-MC AC-8190A-MC AK-8192A-MC AC-8194C-MC AK-8197C-M1 AC-8198C-MC AK-820 1C-MC AC-8210A-MC AK-8212A-MC AC-E664G-MC AK-E665G-MC AC-E667 J-MC AK-E668J-MC (Listing) (Binary PT) (Listing) LSI-11 EIS Instruction Set Test (Binary PT) LSI-11 FIS Instruction Set Test (Listing) (Binary PT) LSI-11 Traps Test (Listing) (Binary PT) (Listing) LSI-11 4K System Exerciser (Binary PT) DECjX11 Processor Test Module (Listing) (Binary PT) DECjX 11 EIS Exerciser Module (Listing) (Binary PT) R R X X 0 R K 0 5 R R L L 1 0 2 2 13 18 1920 2 13 18 1920 2 13 18 19 20 2 13 18 19 20 2 13 18 1920 6 16 18 1920 4 13 18 19 20 4 13 18 1920 4 13 18 1920 4 13 18 1920 4 13 18 1920 1 14 18 1920 1 14 18 1920 0 1 0 2 Module Number Option Name Diagnostic Diagnostic and and DEC/X11 Notes DEC/X11 Module Titles File Names M7940 DLV11 VKAE??BI? 11a,12 DLV11 Test XDLA??OBJ 11a VKAF??BI? 13 DRV11 Test XDRA??OBJ 13 DEC/X11 DR11-A Exerciser Module M7941 01 ()) DRV11 Listing and Paper Tape PNs R R X X R R R K L L 0 0 0 5 1 0 2 1 0 2 4 13 18 1920 5 14 18 1920 4 13 18 1920 5 13 18 1920 13 18 19 20 (Listing) (Binary PT) DEC/X11 DL 11 Exerciser Module (Listing) (Binary PT) AC-8202B-MC AK-8205B-MC AC-E709J-MC AK-E710J-MC (Listing) (Binary PT) (Listing) (Binary PT) AC-8206D-MC AK-8208D-MC AC-E854D-MC AK-E855D-MC (Listing) (Binary PT) (Listing) (Binary PT) AC-8850F-MC AK-8854F-MC AC-9045F-MC AK-9048F-MC 4 (Listing) (Binary PT) (Listing) RX 11 Interface Diagnostic (Binary PT) DEC/X11 RX01 Exerciser Module (Listing) (Binary PT) AC-9334E-MC AK-9337E-MC AC-9339F-MC AK-9343F-MC AC-E736E-MC AK-E737E-MC 7 13 18 1920 7 13 18 1920 6 16 18 1920 M7942 MRV11-AA NA M7944 MSV11-B ZKMA??BI? 4a MOS/Core 0-124K Exerciser ZQMC??BI? 4b 0-124K Memory Exerciser (16K) ZRXA??BI? 7,14 RX11 System Reliability TEST ZRXB??BI? 7 XRXA??OBJ 7 01 M7946 RXV11 12 13 18 19 20 Module Number Option Name Diagnostic Diagnostic and and DECjX11 Notes DECjX 11 Module Titles File Names M7948 DRV11-P NA M7949 LAV11 ZLAE??BI? LA 180 Printer Diagnostic XLPA??OBJ M7950 DRV11-B VDRA??BI? 13,15 VDRB??BI M7951 DUV11-DA XDRF??OBJ 13 ZDUQ??BI? 16 ZDUR??BI? 16 ZDUS??BI? 16 ZDUT??BI? 16 ZDUU??BI? 16 ZDUV??BI? 16 XDUA??OBJ Listing and Paper Tape PNs (Listing) (Binary PT) DECjX 11 LP 11 Exerciser Module (Listing) (Binary PT) AC-8906B-MC AK-8908B-MC AC-E670F-MC AK-E671 F-MC DRV 11-B DMA Interface Diagnostic DRV 11-B Interprocessor Exerciser DECjX 11 DRV 11-B Exerciser Module (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) AC-8178A-MC AK-8180A-MC AC-8182A-MC AK-8184A-MC AC-E739C-MC AK-E740C-MC (Listing) (Binary PT) DUV 11 Off-Line Receiver Tests (Listing) (Binary PT) DUV 11 Off-Line Receiver Timing (Listing) (Binary PT) DUV 11 Off-Line Transmitter Tests (Listing) (Binary PT) DUV 11 Off-Line Timing & Interrupt (Listing) (Binary PT) DUV11 Off-Line Combined Tests (Listing) (Binary PT) DECjX 11 DU 11 Exerciser Module (Listing) (Binary PT) AC-8704C-MC AK-8707C-MC AC-8708B-MC AK-8711B-MC AC-8712B-MC AK-8715B-MC AC-8716B-MC AK-8719B-MC AC-8720B-MC AK-8723B-MC AC-8724B-MC AK-8727B-MC AC-E7181-MC AK-E7191-MC DUV11 Off-Line Logic Tests R R R R X X 0 0 1 2 K 0 5 R L L 0 0 1 2 7 13 18 1920 6 14 18 19 20 8 15 18 1920 8 15 18 1920 5 14 18 19 20 12 15 18 19 20 12 15 18 19 20 12 15 18 19 20 12 15 18 19 20 12 15 18 19 20 12 15 18 19 20 5 14 18 19 20 Module Number Option Name Diagnostic and DEC/X11 Diagnostic and File Names Notes DEC/X 11 Module Titles M7952 KWV11-A VKWA??BI? 17,18 19,20 21 XKWE??OBJ M7954 IBV11-A M7957 MSV11-C DZV11 DEC/X 11 KWV 11-K Exerciser Module IBV 11-A Diagnostic XIBA??OBJ 22,23 24 22,23 24 25 ZKMA??BI? 4a MOS/Core 0-124K Exerciser ZQMC??BI? 4b 0- 124K Memory Exerciser (16K) VDZA??BI? 26,27 VDZB??BI? 26,27 VDZC??BI? 26,27 DZV 11 4 Line Asynch MUX 1 OF 2 DZV 11 4 Line Asynch MUX 2 OF 2 DZV11 Cable and Echo Test VIBA??BI? VIBB??BI? M7955 KWV 11-A Diagnostic , IBV 11-A (30K) Diagnostic IBV 11-A Exerciser Module VDZD??BI? DZV 11 Overlay for ITEP XDZB??OBJ DEC/X 11 DZV 11 Exerciser Module Listing and Paper Tape PNs R R X X R R R K L L 0 0 5 1 0 2 0 1 0 2 (Listing) AC-8222C-MCM 4 13 18 19 20 (Binary PT) (Listing) AK-8225C-MC AC-E920B-MC 5 14 18 19 20 15 18 19 20 (Binary PT) AK-E921B-MC (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) AC-A880A-MC AK-A882A-MC AC-FO 15A-MC AK-F017A-M1 AC-E914D-MC AK-E915D-MC 8 5 14 18 19 20 (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) AC-8850F-MC AK-8854F-MC AC-9045F-MC AK-9048F-MC AC-A877 A-MC AK-A879A-MC AC-A938A-MC AK-A940A-MC AC-A941A-MC AK-A943A-MC AC-A935A-MC AK-A937 A-MC AC-E911 C-MC AK-E912C-MC 4 13 18 19 20 12 15 18 19 20 12 13 18 19 20 9 15 18 19 20 9 15 18 19 20 9 15 18 19 20 9 15 18 19 20 5 14 18 19 20 Module Number Option Name Diagnostic and DEC/Xll Notes File Names M8012 BDV11-AA VM8A??BI? 28,29 30 XBMD??OBJ M8013/ M8014 RLV11 Diagnostic and DEC/Xll Module Titles Listing and Paper Tape PNs BDV 11-AA Diagnostic (Listing) (Binary PT) DEC/X 11 LSI-11 BDV 11 Exerciser (Listing) (Binary PT) (Xl (Xl 8 13 18 1920 1 14 18 1920 AC-B 107B-MC AK-B109B-MC AC-F111B-MC AK-F 108B-MC AC-F 115B-MC 10 17 18 19 20 10 17 18 1920 10 17 18 1920 10 17 18 1920 10 17 18 1920 10 17 18 1920 11 17 18 1920 11 17 18 1920 11 17 18 1920 6 18 1920 RL 11 /RL V 11 Controller Test 1 ZRLH??BI? 7,32 33· RL 11 /RL V 11 Controller Test 2 ZRLI??BI? 7,34 RL01/02 Drive Test 1 (Binary PT) (Listing) AK-F 112B-MC AC-F 119C-MC (Binary PT) (Listing) (Binary PT) (Listing) AK-F116C-MC AC-F 123B-MC AK-F 120B-MC AC-F 127B-MC (Binary PT) RL01/02 Drive Compatibility Test (Listing) (Binary PT) (Listing) RL01/02 Bad Sector File Tool AK-F 124B-MC AC-F 131 B-MC AK-F 128B-MC AC-F 135B-MC ZRLJ??BI? 7,36 RL01/02 Drive Test 2 ZRLK??BI? 7,35 37 RLO 1/02 Performance Exerciser ZRLL ??BI? 7,35 ZRLM??BI? 7,35 38 ZRLN??BI? 7,39 40 ,. 7 XRLA??OBJ RL01/02 Drive Test 3 RL11/RLV11/RL01/RL02 Exerciser 0 0 0 5 1 2 AC-B061 C-MC AK-B063C-MC AC-F060C-MC AK-F061C-MC 7,31 35 • 0 0 2 ZRLG??BI? (]1 R R R K L L 1 (Listing) (Binary PT) (Listing) (Binary PT) (Listing) RLV11 RL01 Diskless Test VRLA??BI? R R X X (Binary PT) AK-F 132B-MC (Listing) AC-F843A-MC (Binary PT) AK-F844-MC (Listing) AC-E965D-MC (Binary PT) AK-E966D-MC 16 Listing and Paper Tape PNs R X 0 1 R X 0 2 (Listing) (Binary PT) AC-A883A-MC AK-A885A-MC 8 13 18 19 20 (Listing) (Binary PT) DEC/X 11 DL 11 Exerciser Module (Listing) (Binary PT) AC-B 150B-MC AK-B 152B-MC AC-E709J-MC AK-E710J-MC 8 13 18 19 20 5 14 18 1920 (Listing) (Binary PT) (Listing) (Binary PT) AC-E 102A-MC AK-E104A-MC AC-E992B-MC AK-E993B-MC 4 13 18 1920 5 14 18 1920 (Listing) (Binary PT) (Listing) (Binary PT) 0-124 K Memory Exerciser (16K) (Listing) (Binary PT) AC-B153A-MC AK-B 155A-MC AC-8850F-MC AK-8854F-MC AC-9045F-MC AK-9048F-MC 8 15 18 1920 4 13 18 1920 LA 180 Printer Diagnostic AC-8906B-MC AK-8908B-MC AC-E670F-MC AK-E671F-MC Module Number Option Name Diagnostic Diagnostic and and DEC/X11 File Names Notes DEC/X11 Module Titles M8016 KPV11-X VKPA??BI? 41,42 43 KPV 11-A Diagnostic M8017 DLV11-E VDVA??BI? llb DLV11-E Off-Line Test XDLA??OBJ llb VKUA??BI? 44 KUV 11-AA (LSI WCS) Diagnostic XKUA??OBJ 45 DEC/Xl1 KUVll-AA Exerciser Module M8018 KUV11-AA 01 ex> CO M8021 M8027 MRVll-BA LPV11 VMRA??BI? ZKMA??BI? 4a,46 ZQMC??BI? 4b,46 ZLAE??BI? XLPA??OBJ LSI-ll UVPROM-RAM (MRVll-BA) Test MOS/Core 0-124K Exerciser (Listing) (Binary PT) DEC/X 11 LP 11 Exerciser Module (Listing) (Binary PT) R R R K L 0 5 0 0 1 2 L 12 13 18 1920 7 13 18 1920 6 14 18 1920 Module Number Option Name Diagnostic and DECjX11 Diagnostic and File Names Notes DECjX 11 Module Titles M8028 DLVll-F VDVC??BI? lla XDLA??OBJ l1a ZRXC??BI? 7 ZRXD??BI? 7 ZRXE??BI? 7 ZRXF??BI? 7 XRXB??OBJ 7 VDLA??BI? 47,48 XDLA??OBJ 48 MSVll-DXj ZKMA??BI? MSVll-EX ZQMC??BI? 4a M8029 RXV21 (J1 co o M8043 M8044/ M8045 DLV11-J 4b DLVll-F Off-Line Test Listing and Paper Tape PNs ,(Listing) (Binary PT) DECjX 11 DL 11 Exerciser Module (Listing) (Binary PT) AC-E0068-MC AK-E008B-MC AC-E709J-MC AK-E710J-MC (Listing) (Binary PT) RX02 SS Performance Exerciser (Listing) (Binary PT) RX02 Formatter Program (Listing) (Binary PT) RX02 FCTNjLog (Listing) (Binary PT) DECjX 11 RX02 Exerciser Module (Listing) (Binary PT) AC-E509A-MC AK-E511A-MC AC-E512B-MC AK-E514B-MC AC-E622A-M2 AK-E624A-M2 AC-E625A-MC AK-E627A-M 1 AC-F098C-MC AK-Fl00C-MC (Listing) (Binary PT) DECjX 11 DL 11 Exerciser Module (Listing) (Binary PT) AC-E 188B-MC AK-E 19OB-MC AC-E709J-MC AK -E71 OJ-MC RX02 Utility Driver DLVll-J Test (Listing) AC-8850F-MC (Binary PT) AK-8854F-MC 0-124K Memory Exerciser (16K) (Listing) AC-9045F-MC (Binary PT) AK-9048F-MC MOS/Core 0-124K Exerciser R R R R R X X 0 0 1 2 K 0 5 L L 0 0 1 2 8 13 18 19 20 5 14 18 19 20 3 13 18 1920 3 13 18 1920 2 13 18 19 20 3 13 18 19 20 6 16 18 19 20 8 15 18 19 20 5 14 18 1920 4 13 18 1920 12 13 18 19 20 Module Number Option Name Diagnostic and DEC/X11 Diagnostic and File Names Notes DEC/X11 Module Titles M8047 MXV11-AX VMXA??BI? 48 ZKMA??BI? 4a ZQMC??BI? 4b XDLA??OBJ 48 MXV 11-AX Diagnostic (Listing) (Binary PT) (Listing) MOS/Core 0-124K Exerciser (Binary PT) 0-124K Memory Exerciser (16K) (Listing) (Binary PT) DEC/X11 DL 11 Exerciser Module (Listing) (Binary PT) AC-E656A-MC AK-E658A-MC AC-8850F-MC AK-8854F-MC AC-9045F-MC AK-9048F-MC AC-E709J-MC AK-E710J-MC (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) DCF11-AA Diagnostic (Listing) (Binary PT) KEF11-AA Diagnostic no. 1 (Listing) (Binary PT) KEF 11-AA Diagnostic no. 2 (Listing) (Binary PT) DEC/X11 Processor Test Module (Listing) (Binary PT) (Listing) DEC/X 11 EIS Exerciser Module (Binary PT) DEC/X11 FP11 Exerciser Module (Listing) (Binarv PT) M8048 MRV11-C NA M8049 DRV11-J VDRC??BI? 49 DRV11-J Diagnostic Test Part 1 VDRD??BI? 49 DRV11-J Diagnostic Test Part 2 JKDA??BI? 50 KTF 11-AA Diagnostic 0'1 co M81~9 KDF11-A II JKDB??BI? JKDC??BI? JKDD??BI? XCPA??OBJ XCPB??OBJ XFPA??OBJ 51 Listing and Paper Tape PNs R R X X R R R K L L 0 0 0 5 1 1 0 2 0 2 12 15 18 19 20 4 13 18 19 20 12 13 18 19 20 5 14 18 19 20 AC-F756AcM 1 AK-F757A-M1 AC-F759A-MC AK-F760A-MC 8 15 18 19 20 8 15 18 19 20 AC-F 138C-MC AK-F 136C-MC AC-F141C-M1 AK-F 139C-MC AC-F241B-MC AK-F240B-MC AC-F244B-MC AK-F243B-MC AC-E664G-MC AK-E665G-MC AC-E667 J-MC AK-E668J-MC AC-E742G-MC AK-E743G-MC 9 13 18 1920 9 13 18 19 20 9 13 18 19 20 9 13 18 19 20 1 14 18 19 20 1 14 18 1920 5 14 18 19 20 Module Number Option Name M9400/ M9401 REV11-X/ TEV11/ BCV1X ZM9A??BI? Bootstrap/Terminator Test XBMC??OBJ DEC/X11 Bootstrap/Terminator ADV11-A VADA??BI? 1 ADV 11 Performance Test XADC??OBJ 2,3 DEC/X 11 ADV 11 Exerciser Module A012 A6001 G653/ H223 AAV11-A MMV11-A Listing and Paper Tape PNs Diagnostic Diagnostic and and DEC/X11 File Names Notes DEC/X11 Module Titles VAAA??BI? AAV11 Diagnostic Test XAAC??OBJ DEC/X 11 AAV 11 Exerciser Module ZKMA??BI? 4a ZQMC??BI? 4b R R R K L L 0 0 0 0 0 1 2 5 1 2 AC-8954E-MC AK-8957E-MC AC-F057N-MC AK-F058N-MC 7 13 18 19 20 1 14 18 1920 (Listing) AC-8174C-MC (Binary PT) AK-8176C-MC (DOC/PT Kit' ZJ250-RB (Listing) ~C-E923B-MC (Binary PT) AK-E924B-MC 8 13 18 1920 1 14 18 1920 (Listing) AC-8169A-MC (Binary PT) AK-8172A-MC (DOC/PT Kit) ZJ248-RB (Listing) AC-E917B-MC (Binary PT) AK-E918B-MC 8 15 18 19 20 1 14 18 19 20 4 13 18 1920 (Listing) (Binary PT) (Listing) (Binary PT) (Listing) (Binary PT) 0-124K Memory Exerciser (16K) (Listing) (Binary PT) MOS/Core 0-124K Exerciser R R X X AC-8850F-MC AK-8854F-MC AC-9045F-MC AK-9048G-MC 12 13 18 1920 Notes 1. Wraparound test and auto-tests require Berg test connector 7012894-00. 2. Requires an analog ground on any channel to be tested. 3. May be run asynchronously if KWV 11 is present in system. If run asynchronously, XKWE??OBJ must be deselected from the DEC/X 11 run. 4a. Memory space under test should be contiguous and read/write. For systems having noncontiguous memory, the memory boundaries must be defined by the operator before running the program. This diagnostic requires 8K of memory space to run in. 4b. This test will run successfully only on an 11/23 processor with a minimum of 16K of memory. 5. LTC must be disabled. 6. VKAA??BI? and VKAD??BI? should be run on the CPU prior to running this test. 7. Scratch media must be mounted in drives to be tested before starting the diagnostic. 8. ZRKJ??BI?, ZRKK??BI?, ZRKL ??BI?, and ZRKI??BI? (if needed) should be run on subsystem before running this test. 9. ZRKJ??BI? should be run on the sybsystem before running this test. 10. ZRKJ??BI? and ZRKK??BI? should be run on the subsystem before running this test. 11 a. A wraparound test connector must be installed to run this test. The connector is not available from stock. The F.E. must make one up himself. The following instructions (excerpted from Tech Tip PDP-11 /03 TT-11) tell how this is done. The following items are required: 1 Berg connector 4 Berg pins #22 wire (12-10918-15) ( 12-10089-07) (90-07350-00). Crimp a short length of wire between two Berg pins. Make up two sets of these. Install one set from pin F to pin J, anQ one set from pin E to pin M of the Berg connector. ~-~-::593 11b. To completely exercise the modem control portion of the DLV11E, a special wraparound connector (H315) must be installed on the modem end of the I/F cable. This test connector loops back certain control lines as well as the data lines. 12. The test has baud rate dependent configuration requirements. Baud Rate No. of Stop Bits No. of Bits 110 All others 2 8 8 13. Requires BC08R test cable for full test of module's data lines. 14. ZRXB??BI? should be run on the subsystem before running this test. 15. If a REV 11 is in the system, DMA refresh must be disabled and CPU refresh must be enabled. 16. H315A connector required for external loopback testing. 17. If customer hardware is connected to the KWV 11 which could inject signals on ST 1, ST2 or slave in inputs, it must be disconnected from the inputs. 18. All switches in switch pack 2 should be left off unless you are instructed otherwise. 19. I/O signal test no. 1 (ST1 in, ST2 out); install a jumper between J 1-SS (ST2 out) to J 1-VV (ST 1 in). Switch Pack 2 Switch State 2 3 4 5 6 7 Off On Off Off On On Not used. Use a program starting address of 210. 594 20. I/O signal test no. 2 (clock overflow tests); install a jumper between J1-RR (clock overflow) to J1-TT (ST2 in). Switch Pack 2 Switch 2 3 4 5 6 7 State Off Off Off On Off On Not used. Use a program starting address of 214. 21. I/O signal test no. 3 (ST 1 out, ST2 in); install a jumper between J1-UU (ST1 out) to J1-TT (ST2 in). Switch Pack 2 Switch State 2 3 4 5 6 7 Off Off Off On On On Not used. Use a program starting address of 220. 22. Test may be run with a "known good module" in the system for comparison. The good module should be located second (electrically) on the bus, with a cable connecting it and the module under test. "known good module" address - 760160 "known good module" vector - 660 23. Starting restrictions: If a free-running clock, such as 60 Hz from the power supply, is attached to the BEVNT bus line on REV C/O/E systems, an interrupt to location 100 will occur when using the OOT "G" and "L" commands. This will happen prior to the program executing the first instruction. This program cannot disable the BEVNT bus line by inhibiting interrupts. 595 User systems reqUiring a free-running clock attached to the BEVNT bus line can temporarily avoid this situation by setting the PSW to 200, loading the PC with the starting address, and then using the lip" command, instead of using the starting address and the "G" command. Before using the ilL" command, the PSW can be set to 200 to inhibit interrupts after loading the absolute loader. 24. Possible program bombs: The first two tests check to see if the IBV 11-A responds to the address the program thinks it is at. If not, a bus error occurs. Bus errors may alter the preset contents of location 4 before the trap is executed. Program control may be transferred to an area of the program which is not set up to handle the trap. Or, control may be passed to some totally unknown and irrelevant piece of code residing accidently in memory. If this occurs, the program will most probably bomb, and it may also overwrite parts of itself. If this occurs, the program must be reloaded before proceeding. 25. If the IB-bus cable is not removed from the module under test, any errors which are detected could be from some device out on the IB-bus and not necessarily from the IBV 11-A. 26. If run in staggered maintenance mode, an H329 staggered turnaround connector is required. 27. If run in external maintenance mode, an H325 cable turn-around connector is required on all lines which have been selected to be tested. 28. This test assumes that the module under test resides in the same backplane where the line time clock is generated. 29. Test 3 assumes that switch no. 5 of E21 is in the ON position. 30. For the rocker switch test, the operator should specify the configuration for the module under test. 31. VRLA??BI? should be run on the subsystem before running this test. 32. VRLA??BI? and ZRLG??BI? should be run on the subsystem before running this test. 33. A KWV 11 programmable line clock is required to run test no. 7. 596 34. VRLA??BI?, ZRLG??BI?, and ZRLH??BI? should be run on the subsystem before running this test. 35. A KWV 11 programmable line clock is required for some tests. 36. VRLA??BI?, ZRLG??BI?, ZRLH??BI?, and ZRLI??BI? should be run on the subsystem before running this test. 37. VRLA??BI?, ZRLG??BI?, ZRLH??BI?, ZRLI??BI?, ZRLJ??BI?, and ZRLN??BI? should be run on the subsystem before running this test. 38. VRLA??BI?, ZRLG??BI?, ZRLH??BI?, ZRLI??BI?, ZRLJ??BI?, ZRLK??BI, and ZRLN??BI? should be run on the subsystem before running this test. 39. VRLA??BI?, ZRLG??BI?, ZRLH??BI?, ZRLI??BI?, and ZRLJ??BI? should be run on the subsystem before running this test. 40. A KWV 11 programmable line clock is required for tests 1 and 4. 41. To check the power fail circuitry, nonvolatile memory must be in the first 4K of memory. 42. Power up option no. 1 should be selected on the CPU module for power fail testing. 43. The module should be in the standard factory configuration. jumpers in: jumpers out: W1-W5, W7, W8, W11, W13-W15 W6, W9, W10, W12 44. If the test is to be run in all address modes, then an extender card and a special test cable (17-00124-01) are required. 45. The exerciser may be run with the module in address modes 1 or 3 only. 46. This test may be run only if RAM is present on the board. 47. All channels must be configured to the same bit-word length. 48. A wraparound connector (H3270) is required for the data wraparound tests for each of the lines to be tested. 49. Requires a BC05W-02 cable to be installed between the Berg connectors. The cable should have a half twist in it. 597 10. JKDB??BI? should be run on the first 16K of memory before running this test. 51. JKDC??BI? should be run on the module before running this test. 598 Media Availability 01 CO CO No. Media Package Identifier Title Notes Media PNs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CZZGG?? CZZGL?? CZZGO?? CZZGY?? CZZGZ?? CZZHD?? CZZHE?? CZZHG?? CZZHQ?? CZZHZ?? CZZID?? CZZIH?? CZZMC?? CZZMD?? CZZMT?? CZZMU?? CZZMZ?? CZZZD?? CZZLA?? CZZLN?? DXDP + 7 DEC/X 11 EXEC 1 DXDP+ 12 RC,RF,RK11 DXDP+ 15 RX11 DIAG DXDP + 25 LSI FLP 1 DXDP + 26 DEC/X 11 EXEC 2 DXDP + 30 DEC/X 11 EXEC 3 DXDP+ 31 LSI FLP 2 DXDP + 33 LSI FLP 3 DXDP + 43 LSI FLP 4 DXDP + 52 RL02 DIAG no. 1 DXDP + 56 RL02 DIAG no. 2 DXDP+ 60 LSI FLP 5 DYDP+ 3 LSI-11 no. 1 DYDP+ 4 DEC/X11 no. 1 DYDP + 20 LSI-11 no. 2 DYDP+ 21 DEC/X11 no. 2 DYDP + 26 LSI-11 no. 3 LSI-11 DKDP + Diagnostic PKG DLDP+ (RL01) Diagnostic PKG no. DLDP + (RL02) Diagnostic PKG 1 AS-9645?-M? AS-9650?-M? AS-9653?-M? AS-9663?-M? AS-9664 ?-M? AS-9668?-M? AS-9669?-M? AS-9671 ?-M? AS-C638?-M? AS-F547?-M? AS-F753?-M? AS-F804?-M? BA-F021 ?-M? BA-F022?-M? BA-F048?-M? BA-F049?-M? BA-F558?-M? AN-9696?-M? AX-E380?-M? BC-F916?-M? 1 1 1 1 1 1 1 1 1 2 2 2 2 2 Documentation Media Kit PNs ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RY ZJ271-RX ZJ271-RX ZJ271-RX ZJ271-RX ZJ271-RX ZJ278-RE ZJ278-RQ ZJ278-RH Notes 1. 2. Documentation/media kit ZJ271-RY contains all of these floppies as well as all of the applicable documentation. Documentation/media kit ZJ271-RX contains all of these floppies as well as all of the applicable documentation. APPENDIX B FLOATING ADDRESSES / VECTORS FLOATING ADDRESSES The conventions for the assignment of floating addresses for modules on . the LSI-11 bus are the same as UNIBUS devices. UNIBUS devices are used to explain the ranking sequence. The floating-address convention used for communications and for other devices that interface with the PDP-11 series of products assigns addresses sequentially starting at 760 010 (or 160 010) and proceeds upward to 763 776 (or 163 776). For the sake of compatibility with UNIBUS conventions, addresses are expressed as consisting of 18 bits (7XX XXX) rather than 16 bits (1 XX XXX). Floating addresses are assigned in the following sequence. Rank UNIBUS Device 2 3 4 5 6 7 8 9 10 DJ 11 DH11 DQ11 DU11 DUP11 LK11A DMC11 DZ11 KMC11 RL 11 (extras) LSI-11 Device DUV11 DZV11 RLV 11 (extras) FLOATING VECTORS The conventions for the assignments of floating vectors for modules on the LSI-11 bus will adhere to those established for UNIBUS devices. UNIBUS devices are used to explain the priority ranking for floa'ting vectors and are included in the subsequent table of trap and interrupt vector:s as a guide for the user. The floating-vector convention used for communications and for devices that interface with the PDP-11 series of products assigns vectors sequentially starting at 300 and proceeding upward to 777. (Some LSI-11 bus modules,. such as the DLV 11 and DRV 11, have an upper vector limit of 377.) The following table shows the sequence for assigning vectors to modules. It can be seen that the first vector address, 300, is assigned to the first DL V 11 in the system. If another DLV 11 is used, it would then be assigned to all the DL V 11 s (up to a maximum of 32); addresses are then assigned consecutively to each unit of the next highest-ranked device (DRV 11 or DLV 11-E, and so forth), then to the other devices according to their rank. 601 Ranking for Floating Vectors (Start at 300 and proceed upward.) , Rank UNIBUS 1 2 3 4 5 6 7 8 9 10 11 12 13 .14 15 16 17 18 19 20 DC11 KL 11, DL 11-A, -B DP11 DM 11-A DN11 DM11-BB DR 11-A DR 11-C PA611 Reader PA611 Punch DT11 DX11 DL 11-C, -D, -E DJ11 DH11 GT40 LPS11 DQ11 KW11-W DU11 602 LSI-11 Bus DL V 11, -F ,. -J DRV11-B DRV11 DLV11-E KWV11 DUV11
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies