Digital PDFs
Documents
Guest
Register
Log In
AA-HH45C-TE
June 1989
33 pages
Original
3.1MB
view
download
Document:
VAXELN Ada Installation Guide
Order Number:
AA-HH45C-TE
Revision:
0
Pages:
33
Original Filename:
AA-HH45C-TE_VAXELN_Ada_Installation_Guide_Jun89.pdf
OCR Text
VAXELN Ada Installation Guide OE 0080 somWare VAXELN Ada Installation Guide Order Number: June AA—HH45C-—TE 1989 This document contains instructions for installing VAXELN Ada on the VMS operating system. It also explains how to read the online release notes before or after installing the product. This document applies to VAXELN Ada Version 2.0 and all maintenance updates throughout that version. Revision/Update Information: This revised manual supersedes the VAXELN Ada Installation Guide (Order Number AA—HH45B-TE) Operating System and Version: VMS Version 5.0 or higher. VAXELN Version 3.1 or higher. Future maintenance releases may require higher versions. Software Version: VAXELN ITS CUR TESTING PROCEDURES digital equipment corporation maynard, massachusetts Ada Version 2.0 First Printing, February 1986 Revised, January 1987 Revised, June 1989 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Digital Equipment Corporation or its affiliated companies. © Digital Equipment Corporation 1986, 1987, 1989. All Rights Reserved. Printed in U.S.A. The postpaid Reader’s Comments forms at the end of this document request your critical evaluation to assist in preparing future documentation. The following are trademarks of Digital Equipment Corporation: ALL—IN-1 DEC DEC/CMS DEC/MMS DECmate DECnet EduSystem IAS MASSBUS PDP PDT P/OS RT ULTRIX UNIBUS VAX VAXcluster VAXELN DECSYSTEM-20 DECUS DECwriter Q-bus Rainbow RSTS VT Work Processor ™ DECsystem—10 DIBOL Professional RSX VMS SHERGED ZK5129 Contents Preface .. 0... ee Preparing to Install VAXELN Ada........... 2.00. cc ee Prerequisite Software .. 0... eee Accessing the Online Release Notes............ 000 0c cee ee ees Installation Procedure Requirements ......... 0.000 cee eee ee ee eee User Account Quotas and Privileges ............ 0.00 eee eee VMS License Management Facility .........0. 00.0 ee eee Using VMSINSTAL .. 2... ees Installing VAXELN Ada ....... 0.2... ee es Installing VAXELN Ada on a VAXcluster.. 0... es After the Installation... 1... 2.0... 0. es Running the Installation Verification Procedure.............. 000 ce eee Error ConditionS 1... 0... 0c ce ee Installing the VAXELN Remote Debugger as a Shared Image.................:. Maintenance Updates ........... 0.0 cee eee ee es Determining and Reporting Problems ............. 000: ee eee ee ns Sample Installation... .. 0... 0... 00. ee ee V 1 1 1 1 3 4 5 6 11 11 11 13 14 15 15 16 Preface This document describes how to install VAXELN Ada on the VMS operating system. It is intended for system managers. This document applies to VAXELN Ada Version 2.0 and all maintenance updates in that version. A major version number is represented by the digits to the left of the decimal point, and the maintenance update version number is indicated by the digits to the right of the decimal point. Keep this document with your distribution kit. You will need it to install maintenance updates or to reinstall VAXELN Ada for any other reason. At the back of this document are two Reader’s Comments forms. If you have any comments about this document, fill out one form and mail it; your comments will be considered for the next revision of the installation guide. For more information about installing VAXELN Ada on VMS systems, see your processor-specific installation/operations guide. The installation procedure is described step-by-step and is, for the most part, self-explanatory. The system prompts you to answer questions and to change volumes, and waits for you to tell it to continue. Defaults appear in brackets ([]) throughout the installation procedure. you type is indicated in red. Text Preparing to Install VAXELN Ada Your bill of materials (BOM) and indented bills report (BIL) specify the number and contents of your media. Be sure to check the contents of your kit against this information. If your kit is damaged or if you find that parts of it are missing, call your Digital representative. Prerequisite Software VAXELN Ada requires Version 5.0 or higher of the VMS operating system. It also requires VAX Ada Version 2.0 or higher and the VAXELN Toolkit Version 3.1 or higher. The VMS operating system comes with a variety of support options, or classes. Classes include such features as networking and RMS journaling. To use VAXELN Ada, your system should be running a version of VMS that includes the classes listed in the Software Support Addendum comes with the Software Product Description (SPD). (SSA), which Accessing the Online Release Notes VAXELN Ada provides online release notes. The prompt to display or print the release notes during the installation appears in step 4 of the installation procedure when you invoke VMSINSTAL with the OPTIONS N parameter. To obtain the release notes after the installation, type or print the file SYS$HELP:VAXELN_ADA02n.RELEASE_NOTES. The n represents the maintenance update of VAXELN Ada covered in the release notes. Thus, in the case of VAXELN Ada Version 2.0, the release notes are in the file SYS$HELP:VAXELN_ADA020.RELEASE_NOTES. Online HELP also directs you to the release notes file. After the installation, type the following command: $ HELP VAXELN ADA RELEASE NOTES Installation Procedure Requirements The installation takes approximately 15 minutes, depending on the type of e WORLD, media and your system configuration. Before installing VAXELN Ada, you must have the following privileges and resources: SETPRV privileges privileges, or CMKRNL, BYPASS, VAXELN Ada and SYSPRV Installation Guide 1 e 5000 blocks of free disk space, minimum, during installation. e If VAXELN Ada already exists on your system and the VAXELN Remote Debugger was specified as a known or shared image, VMSINSTAL automatically attempts to install the new version as a known or shared image. In this case, the installation will require the following number of global sections and global pages: Image Global Sections Global Pages SYS$SYSTEM:RDBG$RDEBUG.EXE 1 42 SYS$SHARE:RDBG$SHARE.EXE 2 186 SYS$MESSAGE:RDBG$SHAREMSG.EXE 1 68 Note that if you are running VAXELN Ada on a VAXcluster, VMSINSTAL automatically installs new versions as known or shared images only on the machine on which the installation is actually performed. You must manually install new versions as known or shared images on other machines using the VMS Install Utility. See the Installing the VAXELN Remote Debugger as a Shared Image section for more information. To determine the number of available global pages on your system, invoke the VMS Install Utility by typing the following commands: $ INSTALL $ INSTALL :== $INSTALL/COMMAND MODE Then type the following command: INSTALL> LIST/GLOBAL/SUMMARY Summary of 379 Global Sections INSTALL> EXIT When Local Memory Global Sections Used, 31922/39978 Global you enter the LIST/GLOBAL/SUMMARY Pages Used/Unused command, the system displays a summary of the number of global sections used, the number of global pages used, and the number of global pages unused. To exit from the VMS Install Utility, type the EXIT command. NOTE If the necessary number of global pages and global sections is not available, the DCL tables (SYS$LIBRARY:DCLTABLES.EXE) could be corrupted in some situations. 2 VAXELN Ada Installation Guide If there are fewer than the required number of global pages avail- able, you can delete an existing known image with the VMS Install Utility, or you can increase the GBLPAGES system parameter by edit- ing the file SYS$SYSTEM:MODPARAMS.DAT and then invoking the SYS$UPDATE:AUTOGEN command procedure. For more information on modifying system parameters and using AUTOGEN, see the Guide to Setting Up a VMS System. You can determine the number of available global sections by invoking SYSGEN as follows: $ RUN SYSS$SYSTEM: SYSGEN SYSGEN> USE CURRENT SYSGEN> SHOW GBLSECTIONS SYSGEN> EXIT Compare the maximum number of global sections with the number of global sections in use displayed by the VMS Install Utility. If the number of global sections used plus the number of global sections required for the remote debugger exceeds the maximum number of global sections, you must increase the number of available global sections before you can install the remote debugger as a shared image. number, you must increase the GBLSECTIONS To increase the system parameter by editing the file SYS$SYSTEM:MODPARAMS.DAT and then invoking the SYS$UPDATE:AUTOGEN command procedure. For more information on modifying system parameters and using AUTOGEN, see the Guide to Setting Up a VMS System. If the number of global sections used plus the number of global sections required for the remote debugger is less than the maximum number of global sections, you can exit from SYSGEN and continue. User Account Quotas and Privileges To use VAXELN Ada, each account must have TMPMBX privileges and the following requirements: e Enqueue quota (ENQLM): 60 (minimum) ¢ Open file quota (FILLM): 50 (minimum) e Paging file quota (PGFLQUOTA): e Subprocess creation quota (PRCLM): 2 (minimum) e Working set size (WSDEF): 750 pages (minimum) and NETMBX 17000 pages (minimum) VAXELN Ada Installation Guide 3 ¢ Working set quota (WSQUOTA): 1500 pages (minimum) ¢ Working set extent (WSEXTENT): 2500 pages (minimum) Use the VMS Authorize Utility (AUTHORIZE) to compare the current values of these quotas with the requirements for VAXELN Ada. The account used in the following example is the SYSTEM account: $ SET DEFAULT SYSSSYSTEM $ RUN AUTHORIZE UAF> SHOW SYSTEM To change the values of these quotas, use the VMS Authorize Utility’s MODIFY command. For more information, see the VMS Authorize Utility Manual. VMS License Management Facility The VMS License Management Facility (LMF) is available with Version 5.0 of the VMS operating system. Before installing VAXELN Ada, you should register and load your VAXELN Ada software license. The license registration information you need is contained in the Product Authorization Key (PAK) that is shipped with VAXELN Ada. The PAK is a paper certificate that contains information about the license you have to run a particular piece of software. During the installation, you are asked if you have registered the VAXELN Ada license and loaded the appropriate authorization key. You must register and load your license for VAXELN Ada before you run the Installation Verification Procedure (IVP) and use the software. To register a license under VMS Version 5.0, first log in to a privileged account. Digital recommends that you register and load the license from the system manager’s account. You then have a choice of two ways to perform the registration: e Invoke the SYS$UPDATE:VMSLICENSE.COM procedure. When it prompts you for information, respond with data from your Product Authorization Key (PAK). e 4 VAXELN Ada Enter the DCL LICENSE REGISTER command with the appropriate qualifiers that correspond to information on the PAK. Installation Guide Depending on the way in which you have registered the VAXELN Ada license, you also have a choice of two ways to load the license: ¢ Type YES in response to the appropriate question when you are running e Enter the DCL LICENSE SYS$UPDATE:VMSLICENSE.COM. LOAD Note that you need the CMKRNL, this command. command. SYSNAM, and SYSPRV privileges to use For complete information on using LMF, see the manual on the License Management Utility in the VMS documentation set. Using VMSINSTAL After you log in to a privileged account to install VAXELN Ada, invoke VMSINSTAL, the command procedure that installs this product. An example of this procedure is shown in steps 1 and 2 of the Installing VAXELN Ada section. The VMSINSTAL command procedure has the following syntax: S @SYSSUPDATE:VMSINSTAL VAXELN ADAO2n ddcu: [OPTIONS N] n Represents the maintenance update of VAXELN Ada. Refer to the label on the VAXELN Ada distribution kit or the bill of materials for the maintenance update number of your kit. For VAXELN Ada Version 2.0, the maintenance update is 0. You can also type an asterisk (*) in place of VAXELN_ADAO2zn. ddcu: Represents a device name where the distribution volumes will be mounted for the VAXELN Ada installation media, where dd is the device code, c is the controller code, and u is the unit number. It is not necessary to use the console drive to install VAXELN Ada. If you do use the console drive, you should replace any media you removed from the drive. MUAO: is the device name used in the examples in this document. OPTIONS N Is an optional parameter you should provide if you want to be prompted to display or print the release notes. If you do not include the OPTIONS N parameter, VMSINSTAL does not prompt you to display or print the release notes. VMSINSTAL permits the use of several other options. For more information on the other options, see your processor-specific installation/operations guide. VAXELN Ada Installation Guide 5 VMSINSTAL requires the product and device names. these parameters, VMSINSTAL prompts you for them. If you do not supply VMSINSTAL will also prompt you for the optional parameter that indicates whether or not you want the release notes displayed or printed. If you wish to be prompted for the product and device names and to display or print the release notes, type the following: 9 @SYSSUPDATE: VMSINSTAL When you invoke VMSINSTAL, it checks the following: e Whether you logged in to a privileged account. Digital recommends that you install software from the system manager’s default device and directory set to SYS$UPDATE. ¢ account with your Whether you have adequate quotas for installation. VMSINSTAL checks for the following quota values: —- ASTLM = 24 — BIOLM = 18 —- BYTLM - DIOLM = 18 —- ENQLM — FILLM = 20 = 18000 = 30 VMSINSTAL then checks whether the following conditions exist. If so, discontinue the conditions before resuming the installation procedure. e Whether DECnet is up and running e Whether any users are logged in to the system If VMSINSTAL detects either of these conditions, you will be asked whether you want to continue the installation. If you want to continue, type YES. If you want to stop the installation, press RETURN. Installing VAXELN Ada This section contains excerpts from the installation procedure and ex- plains each step. Defaults appear in brackets throughout the installation procedure. To abort the installation procedure at any time, press CTRL/Y. When you press CTRL/Y, the installation procedure deletes all files it has created up to that point and then returns you to DCL level. If you want to retry the installation procedure after pressing CTRL/Y, you must proceed from step 2. 6 VAXELN Ada Installation Guide Step 1: Log in to a privileged account and set your default device and directory to SYSS$UPDATE. Username: Password: SYSTEM $ SET DEFAULT SYSSUPDATE Step 2: Invoke VMSINSTAL. $ @VMSINSTAL VAXELN_ADAO2n VAX/VMS Software MUAO: OPTIONS Product Installation It is Enter dd-mmm-yyyy at hh:mm. a question mark (?) at any * you backup Are satisfied with the N time for of Procedure VX.xX help. your system disk [YES]? [RETURN| If you are satisfied with the backup of your system disk, press RETURN. Otherwise, type NO and press RETURN to discontinue the installation. Digital recommends that you back up your system disk before installing any software. Step 3: Insert the installation kit volume. Please mount * Are The you the ready? following VAXELN ADA first YES products volume of will processed: be the set on MUAO:. V2.n Beginning installation SVMSINSTAL-I-RESTORE, of VAXELN ADA V2.n at hh:mm Restoring product saveset A... To indicate that you want to continue the installation, mount volume YES, and press RETURN. 1, type Step 4: Select a release notes option. This step applies only if you specified OPTIONS N in step 2. Mm WN F Release 5. . . Notes Options: Display release notes Print release notes Both 1 and 2 Copy release notes to SYSSHELP Do or * Select not display, option print copy release notes [2]: If you select option 1, VMSINSTAL displays the release notes on line immediately. You can terminate the display at any time by pressing CTRL/C. VAXELN Ada Installation Guide 7 If you select option 2, VMSINSTAL prompts you for a queue name. Either type a queue name or press RETURN to send the file to the default output print device. * Queve name [SYSSPRINT]: If you select option 3, VMSINSTAL displays the release notes on line immediately. You can terminate the display at any time by pressing CTRL/C. VMSINSTAL then prompts you for a queue name. Either type a queue name or press RETURN to send the file to the default output print device. The VAXELN Ada release notes are then copied to SYS$HELP: VAXELN_ADA02n.RELEASE_ NOTES. If you select option 4, VMSINSTAL copies the release notes to SYS$HELP immediately. If you select option 5, VMSINSTAL does not display, print, or copy the release notes; typically you select this option when you want to terminate the installation. NOTE This version of the release notes file installed by VMSINSTAL is labeled with the current product name and version number. Take care not to delete release notes for previous versions of VAXELN Ada. Next, VMSINSTAL displays the following prompt: * Do you want to continue sVMSINSTAL-~I-RELMOVED, moved to SYSSHELP. The the installation?: product release Y notes [RETURN If you want to continue the installation, type YES you type NO or press RETURN, VMSINSTAL In either case, VMSINSTAL have been successfully and press RETURN. If discontinues the installation. moves the release notes to SYS$HELP. Step 5: Select installation options. * Do you want to purge files replaced by this installation [YES]? [RETURN] The directories SYS$EXAMPLES, SYS$HELP, SYS$LIBRARY, SYS$MANAGER, SYS$SYSTEM, SYS$TEST, and ELN$ may contain previous versions of VAXELN Ada files. These files are replaced during the installation with new files, but the old files are not automatically purged. Purging is recommended. In response to the purging prompt, press RETURN purge the files or type NO to keep them. 8 VAXELN Ada Installation Guide to Step 6: Respond to License Registration Queries. VAXELN Ada supports the VMS License Management Facility (LMF). The installation procedure displays license information about your product and then asks if you have registered and loaded your authorization key for VAXELN Ada. The following is an example of such information: Product: Producer: Version: Release Date: * Does this product VAXELN ADA DEC 2.n dd-mmm-yyyy have an authorization key registered and loaded? If you have not registered and loaded your authorization key, you must answer “NO” to this question. If you answer “NO”, the installation still continues. Step 7: Read informational messages. The VAXELN Ada installation procedure produces a number of informational messages that report on the progress of the installation. There are procedure no more questions. The will take approximately remainder of 10 minutes. the installation This kit contains an Installation Verification Procedure (IVP) to verify the correct installation of VAXELN ADA. It can be invoked after the conclusion of this procedure as follows: @SYSSTEST:VAXELN_ADASIVP .COM You must reinstall VAXELN Toolkit. VAXELN sVMSINSTAL-I-RESTORE, Providing VAXELN Ada VAXELN Restoring Remote IVP you install product Library Restoring SVMSINSTAL-I-RESTORE, Providing if Run-Time SVMSINSTAL-I-RESTORE, Providing Ada a new saveset B images and version of the objects. product saveset C product saveset D Debugger. Restoring files. SVMSINSTAL-I-SYSDIR, This product creates system disk directory VMISROOT: [SYSTEST.VAXELN ADA]. SCREATE-I-EXISTS, VMISROOT: [SYSTEST.VAXELN ADA] already exists Providing example Providing HELP program topic files. VAXELN Ada. The success of the installation is indicated by the following message: SVMSINSTAL-I-MOVEFILES, Files will now be moved to their VAXELN Ada target directories... Installation Guide 9 If the installation procedure is successful, the files created by the procedure are moved to their target directories. The following files are created or modified by the installation procedure: SYS$COMMON|[SYSTEST. VAXELN_ADA] and contents (new) SYS$TEST: VAXELN_ADA$IVP.COM (new) ELN$:ADA$DMATH.EXE (new) ELN$:ADA$FMATH.EXE (new) ELN$:ADA$GMATH.EXE (new) ELN$:ADA$HMATH.EXE (new) ELN$:ADA$ELNRTL.EXE (new) ELN$:ADA$ELNVMS.EXE (new) ELN$:RTLSHARE.OLB (modified) ELN$:RTL.OLB (modified) ELN$:RTLOBJECT.OLB (modified) ELN$:ERROR_HANDLING.ADA (new) ELN$:SQRT_SERVER.ADA (new) ELN$:SQRT_SERVER_TESTER.ADA (new) SYS$SYSTEM:RDBG$RDEBUG.EXE (new) SYS$SHARE:RDBG$SHARE. EXE (new) SYS$MESSAGE:RDBG$SHAREMSG.EXE (new) SYS$HELP:RDBG$HELPLIB.HLB (new) SYS$HELP:HELPLIB.HLB (new) SYS$HELP: VAXELN_ADA02n.RELEASE_NOTES (new) If you typed YES in response to the prompt that requests a file purge at step 5, previous versions of the VAXELN Ada files are now purged. Step 8: End the installation procedure. Installation VMSINSTAL $ LOGOUT SYSTEM of VAXELN ADA procedure logged out done at V2.n at completed at hh:mm hh:mm dd-mmm-yyyy hh:mm:ss.ss When the product installation procedure is complete, you can choose to install more products, or to log out (as shown here.) If you removed any media from the console drive before beginning the installation, you should replace it now. 10 VAXELN Ada Installation Guide VMSINSTAL deletes or changes entries in the process symbol tables during the installation. Therefore, if you are going to continue using the system manager’s account and you want to restore these symbols, you should log out and log in again. Installing VAXELN Ada on a VAXcluster If you want to run VAXELN Ada on multiple nodes of a VAXcluster, first check to see that you have the appropriate software license. Then, follow these steps after installing VAXELN 1. Ada: Enter the LICENSE LOAD command to activate the license on each node in the VAXcluster on which VAXELN Ada is to be executed, as described in the VMS License Management Utility Manual. 2. 3. Ifthe other nodes do not share a common system disk with the installation node, you must run a separate installation on each node. If previous versions of VAXELN Ada or remote debugger have been spec- ified as known or shared images, VMSINSTAL automatically attempts to install the new versions as known or shared images. However, if you are running VAXELN Ada on a VAXcluster, VMSINSTAL automatically installs new versions as known or shared images only on the node on which the installation is actually performed. You must manually install new versions as known or shared images on other nodes using the VMS Install Utility. After the Installation VAXELN Ada is now installed. The VAXELN Remote Debugger can be invoked with the DEBUG/REMOTE If VAXELN command. Ada will be used extensively on your system, you can reduce system overhead and memory requirements by installing it as a shared image using the VMS Install Utility. For more information, see the Installing the VAXELN Remote Debugger as a Shared Image section. Running the Installation Verification Procedure The VAXELN Ada installation procedure creates the files needed to run the Installation Verification Procedure (IVP) (see step 7 of the Installing VAXELN Ada section). VAXELN Ada Installation Guide 11 To run the IVP, execute the following command procedure: $ @SYSSTEST:VAXELN_ADASIVP.COM The procedure compiles, links, and builds a VAXELN Ada test program to verify that the packages and run-time library have been properly installed. First, the following message is issued: VAXELN Ada Version 2.n Installation Verification Procedure. Then, a temporary program library is created and defined to be the current program library; the VAX Ada predefined units just installed in ADA$PREDEFINED are entered into the program library. Messages like the following are issued: %ACS-I-CL_ LIBCRE, SACS-I-CL LIBIS, SYSSSYSROOT: Library Current SYSSSYSROOT: program [SYSUPD.ADAELNSIVP_LIB] library created is [SYSUPD.ADAELNSIVP_LIB] The IVP consists of two programs that are compiled, linked, and then built into two versions of a bootable VAXELN system. One version is suitable for copying to a disk; the other is suitable for downline loading. messages are issued: Compiling IVP programs. Linking IVP programs. SsACS-I-CL LINKING, Invoking SACS-I-CL LINKING, Invoking the the VMS VMS An Installation Verification Program type. Answer YES if you want an IVP NO is the default. QBUS - MicroVAX UBUS 62xx: 85xx,8700: 8800: MicroVAX The I, MicroVAX MicroVAX 3600: - 725, 730, 750: for for VAXELN VAXELN target target can be built for built for any of (KA630), KA620, each target CPU the following targets. MicroVAX 3500, 2000: Installation Verifying II Linker Linker The following Verification installation of Procedure VAXELN Remote is building the system... Debugger. Two bootable VAXELN Ada test systems have been provided for each target. They are in directory SYSSCOMMON: [SYSTEST.VAXELN ADA}. VAXELN ADASIVP_target_DISK.SYS is a disk or tape-bootable VAXELN ADASIVP_target_DOWNLINE.SYS is a downline-loadable specified system. system. Use the ELN$:COPYSYS.COM procedure to copy VAXELN ADASIVP_ target _DISK.SYS to a disk or tape and boot it on a target VAX, or use downline load procedures to boot VAXELN ADASIVP target DOWNLINE.SYS. See the VAXELN Ada User’s Manual for more details. 12 VAXELN Ada Installation Guide Any Ada the of these systems will verify that the execution environment of VAXELN has been correctly installed. Because the IVP system does not include Network Service, you cannot use the VAXELN Remote Debugger on these systems. VAXELN Ada Version 2.n Installation Verification Procedure has After you run the IVP, you will have two bootable VAXELN available for you to verify that the VAXELN completed. systems Ada execution environment is correct. SYS$COMMON:[SYSTEST. VAXELN_ADA]:VAXELN_ADAS$IVP__ target_DISK.SYS is a version that can be copied to a disk or tape using ELN$:COPYSYS.COM, and then booted on a target VAX processor; SYS$COMMON:ISYSTEST. VAXELN_ADA]:VAXELN_ADAS$IVP_target_ DOWNLINE.SYS is a version that can be downline-loaded. To verify that the VAXELN Ada execution environment is correct, you should boot one of these systems on a target VAX processor following the instructions in the VAXELN Ada User’s Manual. When you boot one of these systems, the following messages should be displayed on your system console terminal: VAXELN Ada IVP_OK - Job IVP OK IVP_OK IVP_OK - Test Test Test IVP_OK VAXELN Version - Job Ada 1 2.n Installation Verification Program Verification Program starting 2 starting task activated starting task finished Version 2.n Installation passed. If you do not see these messages, or other messages are displayed, the execution environment may be incorrect and you should contact Digital for assistance. Error Conditions If the VAXELN Ada installation procedure fails for any reason, a message like the following is displayed: SVMSINSTAL-E-INSFAIL, The installation of VAXELN ADA V2.n has failed. An error during the installation can occur if one or more of the following conditions exist: e Operating system version is incorrect. e Prerequisite software version is incorrect. ¢ Quotas necessary for successful installation are insufficient (see the Installation Procedure Requirements section). e Process quotas required by VMSINSTAL VMSINSTAL section). are incorrect (see the Using VAXELN Ada Installation Guide 13 e¢ The VMS HELP library is currently in use. e The product was registered incorrectly or not registered. For descriptions of the error messages generated by these conditions, see the VMS System Messages and Recovery Procedures Reference Volume, your processor-specific installation/operations guide, or the VMS License Management Utility Manual. If you are notified that any of these conditions exist, you should take the appropriate action as described in the message. You may need to change a system parameter or increase an authorized quota value. If the installation fails, you must restart the installation procedure from step 2. Installing the VAXELN Remote Debugger as a Shared Image If VAXELN Ada will be used extensively on your system, you can reduce the system overhead and memory requirements by installing the VAXELN Remote Debugger as a shared image. First, determine the number of available global pages and global sections on your system. See the Installation Procedure Requirements information on how to do this. section for Then, invoke the VMS Install Utility and install the remote debugger as a shared image by typing the following commands: $ RU SYSSSYSTEM: INSTALL INSTALL> REPLACE SYSSSYSTEM:RDBGSRUEBUG.EXE/OPEN INSTALL> REPLACE SYSSSHARE: _INSTALL>/SHARED/HEADER RESIDENT INSTALL> EXIT - RDBGSSHARE.EAE/OPEN/SHARED/HEADER RESIDENT | RETURN By using the /HEADER_RESIDENT qualifier, you save disk I/O on image activation (at the expense of a permanently allocated page of memory). By using the REPLACE command, you guarantee that the installation will work whether the images are newly installed or were previously installed. If a file has not been previously installed, you may get a warning message; however, you can ignore the message because the file wi!l be installed correctly. To ensure that the remote debugger is installed as a shared image each time the system is bootstrapped, include the following lines in SYS$MANAGER:SYSTARTUP_V5.COM 14 VAXELN Ada Installation Guide (the site-specific startup file): S$ INSTALL :== SINSTALL/COMMAND MODE S$ INSTALL REPLACE SYSSSYSTEM: RDBGSRDEBUG. EXE/OPEN/SHARED/HEADER RESIDENT REPLACE SYSS$SHARE:RDBGSSHARE.EXE/OPEN/SHARED/HEADER_ RESIDENT EXIT Maintenance Updates Digital may periodically issue maintenance updates of VAXELN Ada. Each update consists of an installation kit. You should install this kit as described in this document or in any documentation that may accompany the maintenance update. Each time a maintenance update is released, the version number changes. For example, if the current version is 2.0, the version number of the first maintenance update will be 2.1. In addition, each maintenance update includes new release notes. The release notes describe the changes that have been made to VAXELN Ada since the previous release. The update release notes are provided on line. You should read the release notes when you first install VAXELN Ada; they are also accessible at any time after the product is installed. For information on reading the release notes at the time that you install VAXELN Ada, follow the installation procedure through step 4. After VAXELN Ada is installed, display or print the file SYS$HELP: VAXELN_ADA02n.RELEASE_NOTES to locate the release notes (where n is the number of the current maintenance update), or type the following command: $ HELP VAXELN Ada Release Notes Determining and Reporting Problems If an error occurs while you are using VAXELN Ada and you believe that the error is caused by a problem with VAXELN Ada, take one of the following actions: e If you purchased VAXELN Ada within the past 90 days and you think the problem is caused by a software error, you can submit a Software Performance Report (SPR). e Ifyou have a Basic or DECsupport Software Agreement, you should call your Customer Support Center. With these services, you receive telephone support that provides high-level advisory and remedial assistance. For more information, contact your local Digital representative. e Ifyou have a Self-Maintenance Software Agreement, Software Performance Report (SPR). VAXELN Ada you can submit a Installation Guide 15 If you find an error in the VAXELN Ada documentation, you should fill out and submit a Reader’s Comments form from the back of the document in which the error was found. error was found. Include the section and page number where the When you prepare to submit an SPR, please take the following steps: 1. Describe as accurately as possible the state of the system and the circumstance when the problem occurred. Include in the description the version number of VAXELN Ada being used. Demonstrate the problem with specific examples. 2. Reduce the problem to as small a size as possible. 3. Remember to include listings of any command files, relevant data files, and so on. 4. Provide a listing of the program. 5. If the program is longer than 50 lines, submit a copy of the program on machine-readable media (floppy diskette or magnetic tape). If necessary, also submit a copy of the program library used to build the application. Use the VMS Backup Utility to copy the program library to the machinereadable media. answered. All media will be returned to you when the SPR is 6. Report only one problem per SPR. This will facilitate a more rapid response. 7. Mail the SPR package to Digital. Eixperience shows that many SPRs do not contain enough information to duplicate or identify the problem. Complete and concise information helps Digital give accurate and timely service to software problems. Sample Installation This section contains a sample installation of VAXELN Ada. Note that this is only a sample. Sometimes the installation procedure is modified in maintenance updates of this product. Because this installation guide is not usually revised for maintenance updates, be sure to read the Read Before Installing or Using VAXELN Ada letter before you install this product. This letter notes any significant changes in the installation that vary from this sample. 16 VAXELN Ada Installation Guide S$ S SET DEFAULT SYSSUPDATE @VMSINSTAL VAXELN ADAO20 VAX/VMS It is 25-APR-1989 Enter a * Are you The Software question following at 17:22. (?) Release Select * Do Notes This be want Ada of to [2]: 4 continue the , The requires Version installation that 5.0 to * you want to Checking for correct disk V2.0 at [YES]? [RETURN] see 17:23 A if following YES notes have been already be successfully products installed: higher, and 3.1 or higher. will now space files verify is these products software check completed by for are present. installation. this installation key registered [YES]? [RETURN | agreements. VAXELN-ADA DEC 2.0 15-MAR-1989 an that available replaced licensing have notes higher, Producer: Version: Release Date: Does this product loaded? YES release prerequsisite enough purge SYSSHELP or copy release Procedure Product: There are procedure system saveset installation? the or procedure Checking * VAXELN ADA product Installation SVAXELN ADA-S-PREREQ OK, Do help. of your product’s VAX Ada Version 2.0 or VAXELN Toolkit Version The V5.0 Options: V2.0-00 product VMS for Procedure processed: Restoring SVMSINSTAL-I-RELMOVED moved to SYSSHELP. VAXELN time Display release notes Print release notes Both 1 and 2 Copy release notes to Do not display, print option you any installation SVMSINSTAL-I-RESTORE, * Installation the backup will N V2.0 Beginning 1. 2. 3. 4 5 at with products OPTIONS Product mark satisfied VAXELN ADA MUAO: authorization no more questions. The will take approximately remainder of 10 minutes. the and installation This kit contains an Installation Verification Procedure (IVP) to verify the correct installation of VAXELN ADA. It can be invoked after the conclusion of this procedure as follows: @SYSSTEST:VAXELN ADASIVP.COM VAXELN Ada Installation Guide 17 You must VAXELN reinstall VAXELN Ada if you install a new saveset B version of the Toolkit. SVMSINSTAL-I-RESTORE, Restoring Providing Run-Time VAXELN Ada SVMSINSTAL-I-RESTORE, Providing VAXELN Restoring Remote sVMSINSTAL-I-RESTORE, Providing IVP product Library images and objects. product saveset C product saveset D Debugger. Restoring files. SVMSINSTAL-I-SYSDIR, This product VMISROOT: [SYSTEST.VAXELN ADA]. sCREATE-I-EXISTS, VMISROOT: Providing example program Providing HELP topic VMSINSTAL system [SYSTEST.VAXELN ADA] disk directory already exists files. VAXELN Ada. SVMSINSTAL-I-MOVEFILES, Installation creates Files will of VAXELN_ADA procedure done at now V2.0 be moved completed to their at 17:33 target directories... 17:34 $ @SYSS$TEST:VAXELN ADASIVP.COM VAXELN ADA Version tACS-I-CL_LIBCRE, 2.0 Installation Library Verification SYS$SYSROOT: Procedure. [SYSUPD.ADAELNSIVP_LIB] SACS-I-CL_LIBIS, Current program library is SYSSSYSROOT: [SYSUPD.ADAELNSIVP_LIB] Compiling IVP programs. Linking IVP programs. SACS-I-CL LINKING, Invoking the VMS Linker for VAXELN target SACS-I-CL_ VAXELN target LINKING, Invoking the VMS Linker An Installation Verification Program can be Answer YES if you want a system image built No is the default. QBUS - MicroVAX I, MicroVAX MicroVAX 3600: YES UBUS - 725, 730, 750: 62xx: 85xx, 8700: 8800: MicroVAX The (KA630), built for each for any of the KA620, MicroVAX target CPU type. following targets. 3500, [RETURN ] 2000: Installation Verification Q-bus IVP building System image size is System image size is Verifying II for created installation 520 520 of Procedure pages pages VAXELN (260K (260K is building the system... bytes) bytes) Remote Debugger. Two bootable VAXELN Ada test systems have been provided for each target. They are in directory SYSSCOMMON: [SYSTEST.VAXELN ADA]. 18 VAXELN Ada Installation Guide specified VAXELN_ADASIVP_target_DISK.SYS is a disk or tape-bootable VAXELN_ADASIVP_target_DOWNLINE.SYS is a downline-loadable Use the ELN$:COPYSYS.COM procedure to copy system. system. VAXELN_ADASIVP_target_DISK.SYS to a disk or tape and boot it on a target VAX, or use downline load procedures to boot VAXELN ADASIVP_target_DOWNLINE.SYS. See the VAXELN Ada User’s Manual for more details. Any of these systems will verify that the execution environment of VAXELN Ada has been correctly installed. Because the IVP system does not include the Network Service, you cannot use the VAXELN Remote Debugger on these systems. VAXELN ADA $ LOGOUT SYSTEM Version 2.0 logged Installation out at Verification 25-APR-1989 Procedure has completed. 17:45:05.61 VAXELN Ada Installation Guide 19 How to Order Additional Documentation Technical Support If you need help deciding which documentation best meets your needs, call 800-343-4040 before placing your electronic, telephone, or direct mail order. Electronic Orders To place an order at the Electronic Store, dial 800-DEC-DEMO (800-332-3366) using a 1200- or 2400-baud modem. If you need assistance using the Electronic Store, call 800-DIGITAL (800-344-4825). Telephone and Direct Mail Orders Your Location Call Contact Continental USA, 800-DIGITAL Digital Equipment Corporation P.O. Box CS2008 Nashua, New Hampshire 03061 Puerto Rico 809-754-7575 Local DIGITAL subsidiary Canada 800-267-6215 Digital Equipment of Canada Attn: DECdirect Operations KAO2/2 P.O. Box 13000 100 Herzberg Road Kanata, Ontario, Canada K2K 2A6 Alaska, or Hawaii International Local DIGITAL subsidiary or approved distributor Internal? SDC Order Processing - WMO/E15 or Software Distribution Center Digital Equipment Corporation Westminster, Massachusetts 01473 1For internal orders, you must submit an Internal Software Order Form (EN-01740-07). Reader’s Comments VAXELN Ada Installation Guide AA-HH45C-TE Please use this postage-paid form to comment on this manual. If you require a written reply to a software problem and are eligible to receive one under Software Performance Report (SPR) service, submit your comments on an SPR form. Thank you for your assistance. I rate this manual’s: Accuracy (software works as manual says) Completeness (enough information) Clarity (easy to understand) Organization (structure of subject matter) Figures (useful) Examples (useful) Index (ability to find topic) Page layout (easy to find information) Excellent Good Fair Poor LJ O LJ L O CL CO CJ LJ C O LJ LJ O C] C L) C C] CJ L) O CO CJ C C) L CJ C) O LJ LO I would like to see more/less What I like best about this manual is What I like least about this manual is I found the following errors in this manual: Page Description Additional comments or suggestions to improve this manual: I am using Version Name/Title of the software this manual describes. Dept. Company Date Mailing Address Phone sma - Do Not Tear - Fold Here and Tape ——————-—— = = No Postage Necessary if Mailed in the United States Se Pp BUSINESS REPLY MAIL FIRST CLASS PERMIT NO. 33 MAYNARD POSTAGE WILL BE PAID BY ADDRESSEE DIGITAL EQUIPMENT CORPORATION Corporate User Publications—Spit Brook ZKO1-—3/J35 110 SPIT BROOK ROAD NASHUA, NH 03062-9987 Do Not Tear - Fold Here Pe Pe MASS. ee pe pe Pp P| —— it Along Dotted Line - II -——- 47 3-7°7 Reader’s Comments VAXELN Ada Installation Guide AA-HH45C-TE Please use this postage-paid form to comment on this manual. If you require a written reply to a software problem and are eligible to receive one under Software Performance Report (SPR) service, submit your comments on an SPR form. Thank you for your assistance. I rate this manual’s: Accuracy (software works as manual says) Completeness (enough information) Clarity (easy to understand) Organization (structure of subject matter) Figures (useful) Examples (useful) Index (ability to find topic) Page layout (easy to find information) Excellent Good Fair Poor L OO O LJ LI LJ O LJ O CI CL] LJ C O CJ OJ O LJ CO LJ OJ LJ L L CJ CO CI C] OJ LJ O LJ I would like to see more/less What I like best about this manual is What I like least about this manual is I found the following errors in this manual: Page Description Additional comments or suggestions to improve this manual: I am using Version Name/Title of the software this manual describes. Dept. Company Date Mailing Address Phone - Do Not Tear - Fold Here and Tape CA EGan —————-—-——--—-—---— ~ Sa cs ec ee T™™ ia No Postage Necessary if Mailed in the United States BUSINESS REPLY MAIL FIRST CLASS PERMIT NO. 33 MAYNARD MASS. POSTAGE WILL BE PAID BY ADDRESSEE DIGITAL EQUIPMENT CORPORATION Corporate User Publications—Spit Brook ZKO1-3/J35 110 SPIT BROOK ROAD NASHUA, NH 03062-9987 Do Not Tear - Fold Here —-——-—-~—————————— — — — — — — — — — — ~~ — — — — —_ ‘ut Along Dotted Line -
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies