Digital PDFs
Documents
Guest
Register
Log In
EK-70TBA-T1-A01
May 1993
25 pages
Original
0.3MB
view
download
Document:
DEC 7000/10000 AXP Technical Bulletin Number 1
Order Number:
EK-70TBA-T1
Revision:
A01
Pages:
25
Original Filename:
OCR Text
DEC 7000/10000 AXP Technical Bulletin Number 1 Order Number EK–70TBA–T1. A01 This document accompanies the release of the OpenVMS AXP Version 1.5 operating system used on DEC 7000 and 10000 systems. Information is given that was not available when the DEC 7000/10000 AXP documents were first published. digital equipment corporation maynard, massachusetts First Printing, May 1993 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software, if any, described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software or equipment that is not supplied by Digital Equipment Corporation or its affiliated companies. Copyright © 1993 by Digital Equipment Corporation. All Rights Reserved. Printed in U.S.A. The following are trademarks of Digital Equipment Corporation: Alpha AXP AXP DEC DECchip DEC LANcontroller DECnet DECUS DWMVA OpenVMS ULTRIX UNIBUS VAX VAXBI VAXELN VMScluster XMI The AXP logo dT OSF/1 is a registered trademark of the Open Software Foundation, Inc. FCC NOTICE: The equipment described in this manual generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such radio frequency interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense may be required to take measures to correct the interference. Contents Section 1 1.1 Changes ................................................................................. 1-2 Section 2 2.1 2.2 Installation Console Load Devices ............................................................. 2-2 Expander Cabinet Installation — Connect the Power Control Cable ....................................................................................... 2-4 Section 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 Introduction User Information Booting OpenVMS AXP from an RRD42 .............................. 3-2 Booting OpenVMS AXP from an InfoServer ........................ 3-4 Booting LFU from an InfoServer .......................................... 3-6 Clear SEEPROM .................................................................... 3-8 Repeat ..................................................................................... 3-9 Set System_Variant ............................................................. 3-10 Set SEEPROM ..................................................................... 3-11 Show SEEPROM .................................................................. 3-12 Examples 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 RRD42 OpenVMS AXP Boot ................................................. 3-2 InfoServer OpenVMS AXP Boot ............................................ 3-4 InfoServer LFU Boot .............................................................. 3-6 Clear SEEPROM Command .................................................. 3-8 Repeat Command ................................................................... 3-9 Set System_Variant Command ........................................... 3-10 Set SEEPROM Command ................................................... 3-11 Show SEEPROM Command ................................................ 3-12 iii Figures 2-1 2-2 2-3 iv Accessing the Console Load Device ....................................... 2-2 Power Control Cable .............................................................. 2-4 Power Control Cable Routing ................................................ 2-5 Section 1 Introduction This technical bulletin provides information to update the DEC 7000/ 10000 documentation set. The OpenVMS AXP operating system, Version 1.5, now provides support for the following: • Symmetric multiprocessing • OpenVMScluster capabilities, including mixed architecture clustering • Booting from an InfoServer Introduction 1-1 1.1 Changes Alpha AXP systems and VAX systems may be clustered together using the CIXCD–AC adapter, which is now supported by OpenVMS AXP Version 1.5. OpenVMS AXP V1.5 supports clustering — of AXP systems and of AXP systems with VAX systems. Version 5.5-2 of the OpenVMS VAX operating system is required for mixed clusters. Mixed clusters also require that each type of system have its own system disk. Now supported: • Symmetric multiprocessing • CD-ROM booting of the operating system and running of the Loadable Firmware Update (LFU) Utility from an InfoServer LFU and console firmware are now distributed on the Alpha AXP Systems Firmware Update CD-ROM, part number AG-PTMW*- BE. This CD replaces the DEC 7000/10000 AXP Console CD, which has been discontinued. For more information: DEC 7000/10000 AXP System Release Notes VMScluster Software for OpenVMS AXP Version 1.5 Software Product Description 1-2 Introduction Section 2 Installation The installation of DEC 7000 and DEC 10000 systems is affected by the release of the OpenVMS AXP Version 1.5 operating system. A system can now be installed as a member of a cluster. That cluster can be composed of both VAX and Alpha AXP systems. The initial system load can be done from either an RRD42 in the system cabinet or from an InfoServer accessed over the Ethernet. Before the operating system is booted, however, some adjustments may need to be made to the hardware. The firmware on various modules may need to be updated, and this is done by running the Loadable Firmware Update (LFU) Utility. LFU is on the Alpha AXP Systems Firmware Update CD-ROM. For systems with expander cabinets, a change was made, for EMC qualification, in how the power control cable from the control panel on the system cabinet connects to the cabinet control logic (CCL) module in the expander cabinet. Section 2.2 supersedes Section 2.18 in the DEC 10000 AXP System VAX 10000 Installation Guide and Section 3.13 in the DEC 7000 AXP System VAX 7000 Installation Guide. With a DEC 7000, however, the first expander cabinet is to the right of the system cabinet, not to the left of the system cabinet as it is for the DEC 10000. When servicing systems, note that CCL modules prior to K04 included a pressure sensor. Revisions K04 and later do not include a pressure sensor. If the module has a pressure sensor, it should be disconnected or removed. Sections include: • Console Load Devices • Expander Cabinet Installation — Connect the Power Control Cable Installation 2-1 2.1 Console Load Devices The RRD42 compact disk (CD) drive in the cabinet or the InfoServer can serve as a console load device. During system installation the console load device is used to boot standalone backup. It is also used to boot the Loadable Firmware Update (LFU) Utility. Figure 2-1 Accessing the Console Load Device XMI KZMSA RRD42 XMI DEMFA InfoServer FDDI DECbridge 500 Ethernet XMI DEMNA InfoServer Ethernet BXB-0005E-92 2-2 Installation You may need to run the Loadable Firmware Update (LFU) Utility to upgrade the firmware on existing modules. You must run LFU to revise the firmware on the CIXCD module. LFU is on the Alpha AXP Systems Firmware Update CD-ROM. To boot LFU from the RRD42 compact disk drive, use the show device command to find the boot information and then boot LFU. P00>>> show device kzmsa* polling for units on kzmsa0, slot 1, xmi0... dka100.1.0.1.0 dka100 RRD42 P00>>> boot dka100.1.0.1.0 -flags 0,80 . . . Bootfile: [DEC7000]AXP7000_Vnn.APB # Or [DEC10000]AXP7000_Vnn.APB where Vnn is the LFU version number (such as V05). The correct file name for this version can be obtained from the Alpha AXP Systems Firmware Release Notes, released with this particular version of the CD-ROM. To boot LFU from the InfoServer, enter the following: P00>>> boot exa0 -file APB_015 -flags 0,80 . . . Bootfile: [DEC7000]AXP7000_Vnn.APB # Or [DEC10000]AXP7000_Vnn.APB 1. Enter 3 to select Choose Service from the Function menu. 2. Enter 1, to select Find Services from the Option menu. 3. Enter the number of the service with the volume label name (Update). 4. LFU starts, displays a summary of its commands, and issues its prompt (Function?). Installation 2-3 2.2 Expander Cabinet Installation — Connect the Power Control Cable Connect the power control cable from the control panel on the system cabinet to the filter board, which is connected to the cabinet control logic (CCL) module in the expander cabinet. Figure 2-2 Power Control Cable Left Expander Front System Right Expander Console Rear Expander BXB-0044i-92 2-4 Installation WARNING: Before beginning this procedure, power off each cabinet at the circuit breaker. 1. Plug one end of the power control cable into the jack marked Left Expander, located on the top right of the system cabinet as viewed from the front. If a second expander cabinet is installed, plug another power control cable into the jack marked Right Expander. 2. Route each power control cable through a cable routing channel to the rear of the system cabinet and into the top of the expander cabinet(s) as illustrated in Figure 2-3. 3. Remove the CCL module access plate on each expander cabinet. The access plate is located in the upper left (as viewed from the rear) of the expander cabinet. Remove the plate by removing the three screws. 4. Plug the other end of each power control cable into jack J1 located on the filter board at the upper right of the CCL module (see Figure 2-2). 5. Replace each CCL module access plate by replacing the three screws. Figure 2-3 System Cabinet Front Power Control Cable Routing System Cabinet Rear Expander Cabinet Rear BXB-0021E-92 Installation 2-5 Section 3 User Information The following pages give information not available when the user documents were published. When the books were published, the DEC 7000 and DEC 10000 systems had their own CD-ROM with firmware update code for those systems. Now there is a CD-ROM that includes firmware update code for all the Alpha systems. To run LFU, the directory and file name for the DEC 7000 and 10000 systems must be given. Topics discussed include: • Booting examples from the RRD42 and from an InfoServer • Booting LFU from an InfoServer • Console command language enhancements — Clear SEEPROM — Repeat — Set System_Variant — Set SEEPROM — Show SEEPROM User Information 3-1 3.1 Booting OpenVMS AXP from an RRD42 This section shows a sample boot of OpenVMS AXP from the RRD42 CD drive for DEC 7000 systems. The first step is issuing the show device command to determine the location of the RRD42. Example 3-1 RRD42 OpenVMS AXP Boot 1 >>> show device polling for units on kdm700, slot 1, xmi0... dua2.2.0.1.0 R2TDYC$DUA2 RF73 dua3.3.0.1.0 R2TDYC$DUA3 RF73 polling for units on kzmsa0, slot 2, xmi0... dka100.1.0.2.0 dka100 RRD42 2 >>> boot -flags 0,0 dka100.1.0.2.0 3 Booting... Connecting to boot device dka100.1.0.2.0 initializing HWRPB at 2000 initializing page table at 1ee000 initializing machine state jumping to bootstrap at 1fa000 OpenVMS AXP (TM) Operating System, Version V1.5 3-2 User Information 4 Insert the compact disk that contains the OpenVMS AXP operating system into the RRD42 CD drive. Example 3-1 shows how to boot the operating system. 1 Show device displays information about each I/O device. Polling checks the XMI bus for device configurations. The next line contains three columns. The first column contains the device type and unit number, node number, device channel number, XMI node number, and I/O channel number, separated by periods. The second column displays the name of the device given by the device controller. The third column shows the device type. 2 In the boot command, -flags indicates that additional command parameters follow, 0 is the system root of the boot device, 0 is the bootstrap option, dk is the device code of the boot device, a is the boot device controller designation, and 100 specifies the hexadecimal unit number of the boot device. The 1 is the node number, 0 is the channel number, 2 is the XMI node number, and 0 is the I/O channel number. 3 The system boots standalone backup from the RRD42. 4 The operating system banner appears. For more information: OpenVMS AXP Version 1.5 Upgrade and Installation Manual User Information 3-3 3.2 Booting OpenVMS AXP from an InfoServer This section shows a sample OpenVMS AXP boot from an InfoServer using the Ethernet. First issue the show network command, followed by the boot command. After the load is complete, choose the service for the operating system. Example 3-2 InfoServer OpenVMS AXP Boot >>> show network 1 polling for units on demna0, slot 3, xmi0... exa0.0.0.3.0 08-00-2B-0B-BB-ED >>> boot exa0.0.0.3.0 -file APB_015 -flags 0,0 2 Initializing... F E . . . . D . . . . C . . . . B . . . . A + . . . 9 . . . . 8 7 6 5 4 3 2 1 0 NODE # A o . o . + . M + . + . + . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P + E + E + E P + B + B + B TYP ST1 BPD ST2 BPD ST3 BPD + . . . . . . . . . . . . . . . . . . . + . . . . . . . + . . . . A0 .128 . . . . . . . . . . . . C0 XMI + C1 C2 C3 . . ILV 128MB Firmware Rev=V2.3-3276[A52] SROM Rev=V1.0-0 SYS SN=GAO1234567 Booting... Connecting to boot device exa0 Created boot device: exa0.0.0.3.0 Requesting MOP Assistance Volunteer..... MOP Assistance Volunteer found. Loading... ...................................... 4 Load complete! 3-4 User Information 3 Insert the compact disk that contains the OpenVMS AXP operating system into an InfoServer. Example 3-2 shows how to begin the boot process. 1 Show network displays information about network controllers. Polling checks the XMI bus for device configurations. Show network includes information such as the console device name of the network device with path information (exa0.0.0.3.0) and the Ethernet controller’s hardware address in hex (08-00-2B-0B-BB-ED). 2 The boot command specifies the console device name of the network device exa0, followed by the initial system load file name APB_015. To boot over the FDDI, the device mnemonic is fx rather than ex. 3 System self-test results are displayed if the environment variable boot_reset is set on. 4 After the load is complete, the Network Initial System Load Function menu is displayed. From the services listed, you choose the service for the operating system CD-ROM. For more information: Console Reference Manual OpenVMS AXP Version 1.5 Upgrade and Installation Manual User Information 3-5 3.3 Booting LFU from an InfoServer You use LFU to update module firmware to the version needed. Make sure the Alpha AXP Systems Firmware Update CD-ROM is mounted in an InfoServer. Example 3-3 InfoServer LFU Boot >>> boot exa0 -file APB_015 -flags 0,80 Booting... Connecting to boot device exa0 Created boot device: exa0.0.0.3.0 Requesting MOP Assistance Volunteer..... MOP Assistance Volunteer found. Loading... ................................. Load complete! Image size: 2144256 Host name: GALL Host address: aa-00-04-00-0c-74 bootstrap code read in base = 127e00, start = 0 boot device name = exa0.0.0.3.0 boot flags 0,0 boot device type = 69 controller ID = a unit number = 0 node ID = 0 channel = 0 slot = 14 hose = 2 jumping to bootstrap at 127e00 Bootfile: [DEC7000]AXP7000_Vnn.APB Network Initial System Load Function Version 1.1 FUNCTION ID 1 2 3 4 5 - FUNCTION Display Menu Help Choose Service Select Options Stop Enter a function ID value: 3 3-6 User Information OPTION OPTION ID 1 Find Services 2 Enter known Service Name Enter an Option ID value: 1 Working Servers found:: 3 Service Name Format: Service Number Service Name Server Name Ethernet ID #1 INFO4$RZ57 INFO4 08-00-2B-26-A6-98 #2 6000_DIAG_H INFO3 08-00-2B-16-04-D4 #3 UPDATE OPUS_ESS 08-00-2B-18-A9-75 Enter a Service Number or <CR> for more: 3 Copyright Digital Equipment Corporation 1991, 1992, 1993. All Rights Reserved. Loadable Environment Rev: V2.3-3359[A33B1] March 22 1993 12:58:47 ***** Loadable Firmware Update Utility ***** Version 8.3 18-Mar-1993 For more information on LFU: Operations Manual, Appendix C System Service Manual, Chapter 3 User Information 3-7 3.4 Clear SEEPROM The SEEPROM is a 2-Kbyte EEPROM on MS7AA, IOP, DWLMA, and DWLAA modules. These SEEPROMs are accessed using a serial protocol, which may take a minute or two for read and write accesses. The SEEPROMs are used to log diagnostic or operating system data and to record module serial numbers. The clear seeprom command clears a specific area in the module’s SEEPROM. Example 3-4 Clear SEEPROM Command P00>>> clear seeprom diag_tdd iop0 P00>>> # Clears the contents # of the DIAG_TDD area # of the IOP module. The clear seeprom command syntax is: cl[ear] see[prom] <option> <device> where option is diag_tdd (test-directed diagnostic area), diag_sdd (symptom-directed diagnostic area), or symptom (operating systemspecific symptom log), and device is iopn (serial EEPROM area on module iopn), ms7aan (serial EEPROM area on module ms7aan), dwlaan (serial EEPROM area on module dwlaan), or dwlman (serial EEPROM area on module dwlman). 3-8 User Information 3.5 Repeat The repeat command reexecutes the indicated command the number of times specified. Example 3-5 Repeat Command >>> repeat 5 ex seeprom:0/iop0 seeprom: 00000C00 AA5500FF seeprom: 00000C00 AA5500FF seeprom: 00000C00 AA5500FF seeprom: 00000C00 AA5500FF seeprom: 00000C00 AA5500FF >>> # Perform the specified # command five times. The repeat command syntax is: r[epeat] [count] [<command>] where count specifies the number of times to repeat the command and <command> is the console command to repeat. If no count is entered, the command will repeat until it is halted by Ctrl/C. User Information 3-9 3.6 Set System_Variant The default value for the system_variant environment variable is 0 (for a DEC 7000). After issuing a build EEPROM command on a DEC 10000 system, you must set the system_variant environment variable to a value of 1. Example 3-6 Set System_Variant Command P00>>> set system_variant 1 # Set system variant # to 1 for DEC 10000. P00>>> The set system_variant command syntax is: se[t] system_variant <value> where value is 0 for a DEC 7000 (default) or 1 for a DEC 10000. 3-10 User Information 3.7 Set SEEPROM The set seeprom command allows you to modify the selected serial EEPROM area. Example 3-7 Set SEEPROM Command >>> set seeprom man iop0 # Enter module serial please wait ~1 min, reading iop0 # number and unified Module Serial Number> SG01234567 # part number. Module Unified 2-5-2.4 Part Number> 19-12345-01.M001 please wait ~1 min, writing iop0 >>> The set seeprom command syntax is: se[t] see[prom] <option> <device> where option is diag_tdd (test-directed diagnostic area), diag_sdd (symptom-directed diagnostic area), manufacturing (module’s serial number area), field (content of field area), or symptom (operating systemspecific symptom log), and device is iopn (serial EEPROM area on module iopn), ms7aan (serial EEPROM area on module ms7aan), dwlaan (serial EEPROM area on module dwlaan), or dwlman (serial EEPROM area on module dwlman). User Information 3-11 3.8 Show SEEPROM The show seeprom command allows you to display information stored in a SEEPROM on a specified module. Example 3-8 Show SEEPROM Command >>> show seeprom diag_sdd iop0 please wait ~1 min, reading iop0 # Show diag_sdd # information. Diagnostic SDD Logging is enabled Logging Control Field value = 0000 Actions logged = 0 >>> The show seeprom command syntax is: sh[ow] see[prom] <option> <device> where option is diag_tdd (test-directed diagnostic information), diag_sdd (symptom-directed diagnostic information), manufacturing (module serial number), field (field service history), or symptom (operating system-specific symptom log), and device is iopn (serial EEPROM area on module iopn), ms7aan (serial EEPROM area on module ms7aan), dwlaan (serial EEPROM area on module dwlaan), or dwlman (serial EEPROM area on module dwlman). 3-12 User Information Index A Alpha AXP CD-ROM, 1-2 Show device command, 2-3, 3-2 Show network command, 3-4 Show SEEPROM command, 3-12 B Booting LFU, 3-6 OpenVMS AXP, 3-2, 3-4 Boot command, 3-2 C Clear SEEPROM command, 3-8 Console load devices, 2-2 E Expander cabinet cabling, 2-4 I InfoServer booting, 2-2 L LFU utility, 2-1, 2-2 P Pressure sensor, removed, 2-1 R Repeat command, 3-9 S Serial EEPROM (SEEPROM), 3-8 Set SEEPROM command, 3-11 Set system_variant command, 3-10 Index-1
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies