Digital PDFs
Documents
Guest
Register
Log In
XX-6F48F-B3
December 1969
4 pages
Original
3.7MB
view
download
OCR Version
2.5MB
view
download
Document:
PDP11 Price-List
Order Number:
XX-6F48F-B3
Revision:
Pages:
4
Original Filename:
PDP11_Price-List_19691215.pdf
OCR Text
Qo PORORBE oecenber 15, 1969 ‘\'\e PDP-11/10 Q? Computer Consisting of: (1) (1) (1) (1) (1) PDP-11/10-AA PDP-11/10-AB PDP-11/10-BA PDP-11/10-BB PDP-11/10-CA price list PDP-11/20 KA11 Central Processor 1K words 16-bit Read Only Memory 128 words 16-bit Read/Write Memory Turnkey Console Basic Mounting Box and Power Supply PDP-11/20 Computer Consisting of: (1) (1) (1) Programmer's Console Basic Mounting Box and Power Supply ASR-33 Teletype and Control Note 2 8350 A 3 3 110 - Note 2 Yes Above - rack mountable, slides included 115V 60 Hz Same except 230V 50 Hz Above - table top model, cover included 115V 60 Hz Same except 230V 50 Hz Above - rack mounted, slides and cabinet included 10,800 10,800 10,800 10,800 11,450 115V 60 Hz PDP-11/20-CB - 7700 7700 7700 7700 8350 None KA11 Central Processor 4K 16-bit Read/Write Memory 100 Yes PDP-11/10-CB (1) (1) (See Note1) RE Above - rack mountable, slides included 115V 50/60 Hz Same except 230V 50/60 Hz Above - table top model, cover included 115V 50/60 Hz Same except 230V 50/40 Hz Above - rack mounted, slides and cabinet included 115V 50/60 Hz Same except 230V 50/60 Hz PDP-11/20-AA PDP-11/20-AB PDP-11/20-BA PDP-11/20-BB PDP-11/20-CA A Same except 230V 50 Hz 11,450 CORE STORAGE MMI11-E 4K Words of 16-bit Read/Write PDP-11/10 Core Memory - 1.2 ps cycle time or 3500 B 1 0 25 150 Note 2 Yes PDP-11/20 MR11-A 1K Words of 16-bit Read-only . : PDP-11/10 or Core Memory - 500 nanoseconds access tim 1500 B;C ) 0 18 150 Note 2 Yes PDP-11/20 Reweaving of MR11-A MR11-A 350 B,GC' = - - - Includes braid and cores MWI11-A Note 2 Yes 128 Words of 16-bit Read/Write Memory - 2.0 ps cycle time PDP-11/10 or 750 BC - - 5 60 Note 2 Yes PDP-11/20 MEIL PK ~-o0M o1 YK KW11-L TS0 Y, oo CLOCKS v, 7 > and ZyvL Real Time Clock - Line Frequency. Causes interrupt PDP-11/10 each 16.6 ms (60Hz) or 20 ms (50Hz) 250 D 0 0 2 ~or PDP-11/20 50 Note 2 Yes PAPER TAPE PC11 High Speed Paper TupeAReader PDP-11/10 (300 cps) and Punch (50 cps) with control 115V 60 Hz PCI1-A or PDP-11/20 Same as PC11 except that it requires 115V 50Hz PDP-11/10 230V requires H-722 or PDP-11/20 TS e T e 3900 B 0 1 25 300 Note 2 Yes 3900 B 0 1 25 300 Note 2 Yes & o < P ‘\'\Q’ PR11 Q° High Speed Paper Tape Reader (300 cps) with Control PDP-11/10 115V 50/60 Hz 230V requires H-722 H-722 2400 B or PDP-11/20 Transformer 100 E (SeeNotel) 0 1 - - 15 150 Note 2 Yes -- - 230V to 115V 50/60 Hz required for 230V operation Note 2 Yes of PC11 and PR11 LT33-DC ASR-33 Teletype PDP-11/10 115V 60 Hz or 1500 - - - 30 120 No 1500 - - - 30 120 No 1200 - - - 25 80 No 1200 -- - - 25 80 No B 0 1 é 60 PDP-11/20 LT33-DD 8 ASR-33 Teletype PDP-11/10 230V 50 Hz or PDP-11/20 LT33-CC KSR-33 Teletype PDP-11/10 115V 60 Hz or PDP-11/20 LT33-CD KSR-33 Teletype PDP-11/10 230V 50 Hz or PDP-11/20 KL Teletype Control for LT33 PDP-11/10 400 or Note 1 Note 2 Yes PDP-11/20 INTERFACE EQUIPMENT DDI11-A BBI1 Peripheral Mounting Panel (includes UNIBUS Connector Module- M920) PDP-11/10 or Prewired System Unit for small peripheral controllers PDP-11/20 Blank Mounting Panel - Wired for bus and power None 178 B 1 - 90 B 1 - . - 50 - 50 Note 2 Yes Note 3 Yes (Does not include UNIBUS connector Module - M920) For custom interface design and mounting M783 UNIBUS Transmitter Module None 30 - - - UNIBUS to Device interface drivers (12) drivers M784 Note 3 Yes UNIBUS Receiver Module None 30 - - - - - Note 3 Yes UNIBUS to Device interface receivers (16) receivers M785 UNIBUS Transceiver Module None 35 - - - - - Note 3 Yes UNIBUS/Device interface drivers and receivers (8) receivers and (8) drivers M105 Address Selector Module (4 Addresses) None 65 - - - 2 - Note 3 Yes M782 Interrupt Control Module (2 interrupt capability) None 100 - - - 2 - Note 3 Yes M920 UNIBUS Connector Module None (Jumper module to interconnect System Units) BC11A UNIBUS Cable BC11A-2 BC11A-5 BC11A-8A BC11A-10 BC11A-15 BC11A-25 45 - - - - - g Length Note 3 L L 8'6" 10' 15' 25! Note 3 Yes 80 90 100 i 110 125 160 -- - - -- -- Yes MOUNTING BOXES AND POWER SUPPLIES BA11-EC BAT1-ES H720-A Extension Mounting Box with Table Top Cover -- 450 -- Extension Mounting Box with Tilt and Lock Chassis Slides -- 400 Power Supply 115V 50/60 Hz - 500 Includes a fan and BC11A-8A UNIBUS Cable Includes fans and BC11A-8A UNIBUS Cable (See Note 1) 3 60 - 3 60 - - - = = - - B - Note 2 Yes Note 2 Yes Note 2 Yes H720-B Power Supply 230V 50/60 Hz -- 500 B - - -- -- Note 2 Yes H960-CA Free Standing Base Cabinet - 650 - - - - -- Includes fans, power distribution panel, extension feet, front bezel panels H952-HA Free Standing Table Note 2 Yes B 120 -- - - -- -- with adjustable height legs for use with H960-CA cabinet Note 2 Yes SPARE PARTS SP11-KA KA1 Spare Parts PDP-11/10 2590 - - - - - or Note 2 Yes PDP-11/20 SP11-MM MMI11-E Spare Parts PDP-11/10 700 - - - - - or Note 2 Yes PDP-11/20 SP11-PS Spare Parts for H720 - 195 - - - - - Note 2 Yes MOUNTING CODES A - Mounts in Basic Mounting Box B - Mounts in Basic or Extension Mounting Box PC14 C - One MRII-A and one MWII-A mount in a single System Unit which is included with the purchase of the MRII-A option. Each MRII-A requires one System Unit of mounting space and provides space for one MWII-A, 3 D - Mounts in the KAIl Processor E - Mounts on rear door of H960-CA or similar cabinet READER/PUNCH PDP-11 CONTROL PANEL AND BASIC MOUNTING BOX TABLE (OPTIONAL) ALWAYS RESERVED FOR PDP-1{ EXTENSION MOUNTING BOX H960-CA BASIC CABINET Note | When ordering PDP-I| systems it is important that sufficient mounting hardware is ordered to accommodate each system. given to the number of DDII's required and whether a BAII-EC or BAII-ES Extension Mounting Box is needed. Particular attention should be DDIl's are System Units prewired to mount small peripheral controllers such as a Teletype control or a High Speed Paper Tape Reader/Punch control, Each DDII can hold four controllers and mounts in 1/6 of a Basic or Extension Mounting Box. To determine the number of DDIl's to order, total the products of the number of spaces required for each item ordered times the quantity ordered. Subtract four from this number and divide by four. Round up to the next whole number, if there is a remainder. Order this number of DDII's. # of "Spaces” used -4 = # of DDI|'s needed Note: 4 Round up to a whole number, = Six System Units will mount in either the Basic or the Extension Mounting Box. To determine whether to order an Extension Mounting Box, total the products of the number of System Units required for each item ordered times the quantity ordered. Include DDIl's and BBIl's, Add one and divide the new total by six and round up to the next whole number if there is a remainder. If the result is one, an Extension Mounting Box is not needed. If the result is two, order an Extension Mounting Box (BAII-ES or BAII-EC) and Power Supply (H720A or H720B). # of System Units used +| = # of Mounting Boxes Required 6 Note: Round up to a whole number, If the result is greater than one an Extension Mounting Box is needed. Note 2 Discountable under a PDP-I1 Discount Agreement. Note 3 Discountable under a Module Discount Agreement. All prices quoted are FOB Maynard, Massachusetts and apply in the continental United States only. prices and specifications are subject to change without notice. Federal, state, and local taxes are not included. dlilgliltlall DIGITAL EQUIPMENT CORPORATION, Maynard, Massachusetts, Telephone: (617) 897-5111 « ALABAMA, Huntsville « CALIFORNIA, Anaheim, Los Angeles, and Palo Alto « COLORADO, Denver » CONNECTICUT, New Haven ¢ DISTRICT of COLUMBIA, Washington (College Park, Md.) FLORIDA, Orlando* GEORGIA, Atlanta ILLINOIS, Chicago » MASSACHUSETTS, Cambridge and Waltham * MICHIGAN, Ann Arbor « MINNESOTA, Minneapolis, * MISSOURI, St. Louis « NEW JERSEY, Parsippany and Princeton « NEWMEXICO, Albuquerque « NEW YORK, Centereach (L.1.), New York City, and Rochester o NORTH CAROLINA, Chapel Hill ¢« OHIO, Cleveland and Dayton « PENNSYLVANIA, Philadelphia and Pittsburgh « TENNESSEE, Knoxville » TEXAS, Dallas and Houston « UTAH, Salt Lake City s WASHINGTON, Seattle « AUSTRALIA, Brisbane, Melbourne, Perth, and Sydney « CANADA, Edmonton, Alberta: Carleton Place, Ottawa, and Toronto, Ontario; and Montreal, Quebec « ENGLAND, London, Manchester, and Reading » FRANCE, Paris » GERMANY, Cologne and Munich « HOLLAND, The Hague ¢ ITALY, Milan o JAPAN, Tokyo « SWEDEN, Stockholm « SWITZERLAND, Ceneva Printed in U.S.A. All
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies