XX-FEF04-28
June 2005
1 pages
Original
28.0kB
view
download
Document:
AN-039
Order Number:
XX-FEF04-28
Revision:
0
Pages:
1
Original Filename:
AN-039.pdf
OCR Text
CHARON-VAX application note AN-039 Remote Management of CHARON-VAX Author: Ralf van Diesen Applies to: CHARON-VAX products for the Windows platform Date: 3 June 2005 Many CHARON-VAX system managers are not located close to their CHARON-VAX host system but yet they are able to manage their CHARON-VAX systems remotely. At first this seems impossible as CHARON is protected in such a way that it resists starting and will stop and display "Error 38" that means "Terminal Server / Citrix Winframe found." This message appears when you try to start the emulator with a remote desktop connection. Solution To overcome this, login to the windows host locally first, then you can take the system over with a Remote desktop connection. However if you reboot the system you will need to login to the windows host first. If you need to manage the pc remotely use VNC instead or use the /console option with the remote desktop. Implementation VNC can be downloaded as freeware : http://vnc.com/download.html [30-18-039] ©2005 Software Resources International. This document is provided for information only and is not a legally binding offer. Software Resources International reserves the right to change the product specifications without prior notice or retire the product. The CHARON name and its logo are a registered trademark of Software Resources International.