Digital PDFs
Documents
Guest
Register
Log In
EK-356KB-UG-C01
March 1997
38 pages
Original
0.2MB
view
download
Document:
StorageWorks 16-Bit Pedestal (BA356-Series) User's Guide
Order Number:
EK-356KB-UG
Revision:
C01
Pages:
38
Original Filename:
OCR Text
DIGITAL StorageWorks 16-Bit Pedestal (BA356-Series) User's Guide Part Number: EK-356KB-UG. C01 March 1997 This guide describes the procedures to install, and operate a deskside expansion pedestal (BA356−K series). Digital Equipment Corporation Maynard, Massachusetts March 1997 While DIGITAL believes the information included in this publication is correct as of the date of publication, it is subject to change without notice. Digital Equipment Corporation makes no representations that the interconnection of its products in the manner described in this document will not infringe existing or future patent rights, nor do the descriptions contained in this document imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. FCC ID: AO9–BA356 ___________________NOTE ________________________ This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modifications made to this equipment may void the users authority to operate this equipment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ____________________________________________________________________ © Digital Equipment Corporation 1995, 1997 All Rights Reserved. Printed in the United States of America. The following are trademarks of Digital Equipment Corporation: CI, DEC, DIGITAL, Digital, DSA, DSSI, HSC, RZ, StorageWorks, VAX, and the DIGITAL logo. The following are third-party trademarks: Adobe and PostScript are registered trademarks of Adobe Systems, Incorporated. Helvetica and Times are registered trademarks of Linotype Co. Hewlett-Packard is a registered trademark of Hewlett-Packard Company Sun Microsystems is a registered trademark of Sun Microsystems, Inc. Microsoft and MS-DOS are registered trademarks and Windows is a trademark of Microsoft Corporation. UNIX is a registered trademark of American Telegraph and Telephone Company. All other trademarks and registered trademarks are the property of their respective holders. Word for Windows 6.0 is a trademark of Microsoft Corporation. This document was produced using Word for Windows 6.0 ii Contents Preface Intended Audience............................................................................................................... v Structure .............................................................................................................................. v Documentation Conventions ................................................................................................ v Related Documents............................................................................................................. vi 1 Introducing the StorageWorks Pedestal Product Description ......................................................................................................... 1–2 Features ........................................................................................................................... 1–2 Product Specifications ..................................................................................................... 1–4 StorageWorks Building Blocks (SBBs)............................................................................ 1–5 Power .............................................................................................................................. 1–6 Cooling............................................................................................................................ 1–8 2 Installing a Pedestal Planning the Installation .................................................................................................. 2–1 Selecting the Installation Area ......................................................................................... 2–2 SCSI Cables..................................................................................................................... 2–3 Installing the SCSI Cables ............................................................................................... 2–3 Installing the Power Cord ................................................................................................ 2–5 Installing SBBs................................................................................................................ 2–6 Checking Pedestal Operation ........................................................................................... 2–6 Connecting the Controller................................................................................................ 2–7 Moving the Pedestal ........................................................................................................ 2–7 3 Operating a Pedestal Operational Status............................................................................................................ 3–1 Replacing SBBs and Power Supplies ............................................................................... 3–2 Replacing a Blower Assembly ......................................................................................... 3–5 Disassembling a Pedestal ................................................................................................. 3–6 Glossary iii Figures Figure 1–1 Typical Deskside Expansion Pedestal............................................................ 1–1 Figure 1–2 Typical 16-Bit SBB Shelf.............................................................................. 1–2 Figure 1–3 Pedestal Dimensions ..................................................................................... 1–4 Figure 1–4 Typical 3.5-Inch SBB.................................................................................... 1–5 Figure 1–5 Typical 5.25-Inch SBB.................................................................................. 1–5 Figure 1–6 Typical 3.5-Inch SBB.................................................................................... 1–6 Figure 1–7 Power Distribution Unit—Rear View ............................................................ 1–6 Figure 1–8 Typical 3.5-Inch SBB.................................................................................... 1–7 Figure 1–9 Power Distribution Unit—Rear View ............................................................ 1–7 Figure 1–10 Blower Assemblies Locations ..................................................................... 1–8 Figure 2–1 Typical Device Certification Label ............................................................... 2–1 Figure 2–2 Pedestal Installation Dimensions ................................................................... 2–2 Figure 2–3 SCSI Cables—Primary Path .......................................................................... 2–3 Figure 2–4 SCSI Cables—Alternate Path ........................................................................ 2–4 Figure 2–5 16-Bit Expander I/O Module......................................................................... 2–4 Figure 2–6 16-Bit SBB Shelf I/O Module ....................................................................... 2–4 Figure 2–7 8-Bit SBB Shelf I/O Module ......................................................................... 2–4 Figure 2–8 Power Cord Routing...................................................................................... 2–5 Tables Figure 1–1 Typical Deskside Expansion Pedestal............................................................ 1–1 Figure 1–2 Typical 16-Bit SBB Shelf.............................................................................. 1–2 Figure 1–3 Pedestal Dimensions ..................................................................................... 1–4 Figure 1–4 Typical 3.5-Inch SBB.................................................................................... 1–5 Figure 1–5 Typical 5.25-Inch SBB.................................................................................. 1–5 Figure 1–6 Typical 3.5-Inch SBB.................................................................................... 1–6 Figure 1–7 Power Distribution Unit—Rear View ............................................................ 1–6 Figure 1–8 Typical 3.5-Inch SBB.................................................................................... 1–7 Figure 1–9 Power Distribution Unit—Rear View ............................................................ 1–7 Figure 1–10 Blower Assemblies Locations ..................................................................... 1–8 Figure 2–1 Typical Device Certification Label ............................................................... 2–1 Figure 2–2 Pedestal Installation Dimensions ................................................................... 2–2 Figure 2–3 SCSI Cables—Primary Path .......................................................................... 2–3 Figure 2–4 SCSI Cables—Alternate Path ........................................................................ 2–4 Figure 2–5 16-Bit Expander I/O Module......................................................................... 2–4 Figure 2–6 16-Bit SBB Shelf I/O Module ....................................................................... 2–4 Figure 2–7 8-Bit SBB Shelf I/O Module ......................................................................... 2–4 Figure 2–8 Power Cord Routing...................................................................................... 2–5 iv Preface The DIGITAL StorageWorks 16-Bit Pedestals (BA356–K Series) User’s Guide describes the BA356 pedestals and compatible StorageWorks components. This guide discusses some of the basic pedestal applications. The information in this document supplements, but does not replace, the information in the SBB shelf user’s guides. Intended Audience This document is for use by personnel responsible for designing, configuring, assembling, installing, and operating pedestals. Structure The organization of this publication is as follows: Chapter 1 An introduction to the pedestals that includes product description, features, shelves, building blocks, power, blower assemblies, and product specifications. Chapter 2 Detailed procedures for installing a pedestal including planning the installation, selecting and routing SCSI cables, pedestal power and cooling, and testing the pedestal. Chapter 3 Procedures for determining pedestal and SBB operational status and basic replacement procedures Documentation Conventions The documentation conventions used in this publication are as follows: boldface type Boldface type indicates the first instance of terms being defined in the te both. italic type Italic type indicates emphasis and complete guide titles. Italic type in the glossary indicates a cross-reference. Related Documents The following is a list of other StorageWorks user documents that are applicable to pedestals. Document Title vi Order Number 16-Bit SBB User’s Guide EK-SBB16-UG StorageWorks Solutions BA356 16-Bit Shelf and SBB User’s Guide EK–BA356–UG StorageWorks Solutions SBB Shelf I/O Module User’s Guide EK-SBBIO-UG StorageWorks Solutions SBB User’s Guide (8-Bit) EK-SBB35-UG 1 Introducing the StorageWorks Pedestal This chapter is a general description of the StorageWorks™ BA356-series 16-bit pedestal. This description includes features, components, StorageWorks building blocks (SBBs), power, cooling, and specifications. Subsequent chapters describe installation and operation. Figure 1–1 Typical Deskside Expansion Pedestal CXO-4371A-MC ™ Trademark of Digital Equipment Corporation DIGITAL StorageWorks 16-Bit Pedestals 1–1 Introducing the StorageWorks Pedestal Product Description The pedestal (see Figure 1–1) encloses a StorageWorks building block shelf (SBB shelf). This low-cost, mass storage solution enables you to design an extremely flexible storage array to meet both your current and future needs. The basic component of the deskside expansion pedestal is a 16bit, single ended SCSI bus shelf (see Figure 1–2). Figure 1–2 Typical 16-Bit SBB Shelf 7 6 5 4 3 2 1 0 CXO-4319A-MC This shelf can accommodate either 3.5-inch or 5.25-inch StorageWorks building blocks (SBBs) in various combinations to create a storage array specifically suited to your needs. You have the option of using any StorageWorks compatible disk drive, tape drive, CD-ROM, or other SBB storage device. However, the SCSI bus controller capabilities and the pedestal physical limitations can restrict the number of SBBs, the SBB types, and the combination of SBB types you install in a pedestal or on a single SCSI bus. The shelf capability determines the following: • Possible SCSI bus configurations • Maximum SCSI cable lengths • Device address range The 16-bit shelf has both CE-Mark and FCC Class B certification. The SBB FCC certification therefore determines the pedestal location. You can use an SBB with FCC Class B certification in a home environment. When you install Class A certified SBBs in pedestal you can only use the pedestal in a commercial environment. __________________ Caution _______________________ There is no provision for installing a controller shelf in a pedestal. DIGITAL neither supports nor recommends such a configuration. ____________________________________________________________________ Features All StorageWorks pedestals have the following features: • Locking front and rear bezels that prevent unauthorized removal of SBBs. • Flexibility to design a storage array subsystem that meets your specific needs. • An ac distribution unit with switch-controlled ac outputs. • You can connect, or “daisy-chain,” the ac power from one pedestal to another. The shelf and SBB features include the following: 1–2 DIGITAL StorageWorks 16-Bit Pedestals Introducing the StorageWorks Pedestal • You can mix 3.5-inch and 5.25-inch SBBs in a single pedestal. • You can install a second shelf power supply, the redundant power option. • Redundant blower assemblies, either one of which can cool the pedestal should the other blower fail. • You can “daisy-chain” the ac power to multiple pedestals. • The power supply SBBs provide a visual display of shelf status (power, cooling). • The device SBB LEDs provide a visual display of storage device status (operation, fault). Table 1–1 is a synopsis of the basic features of the 16-bit pedestal. Table 1–1 16-But SBB Shelf Features Feature SCSI Buses Supported Description 8-Bit Single Ended 16-Bit, Single Ended Device Address 0-15 SCSI Cable I/O Module Connectors Two 16-bit shelf expander I/O module 68-pin, high-density (VHDCI) Two 16-bit shelf I/O module 68-pin, high-density (SCSI “P”) Two 8-bit shelf I/O module 50-pin, high-density (SCSI “A”) SCSI Bus Configurations Single Bus Split Bus SCSI Bus Configuration Control Terminator Board (BA35X-ME) Jumper Board (BA35X-MF) 16-Bit SBB Shelf Expander I/O Module, Single Ended (BA35X-FA, BA35X-FB) 16-Bit SBB Shelf I/O Module (BA35X-MH) 8-Bit SBB Shelf 1/O Module (BA35X-MG) Supported Storage Devices 3.5-Inch SBB 5.25-Inch SBB Supported Shelf Power Supplies ac input Blower Assemblies Dual Speed (BA35X-MD) __________________ Note__________________________ The pedestal does not support either dc power supplies or 5.25-inch tape drives with a loader. ____________________________________________________________________ DIGITAL StorageWorks 16-Bit Pedestals 1–3 Introducing the StorageWorks Pedestal Product Specifications Figure 1–3 and Table 1–2 show the basic pedestal specifications. Figure 1–3 Pedestal Dimensions 0.8 m (2.5 ft) 1m (3.3 ft) 1.9 m (6.3 ft) CXO-4406A-MC Table 1–2 Typical Pedestal Specifications Dimension Metric English Dimensions (Without Service Areas) Height 0.6 m 2 ft Width 0.3 m 1 ft Depth 0.4 m 1.3 ft Weight (No SBBs) 17 kg 37 lb Door Clearance (Front and Rear) 0.3 m 1 ft Ventilation (Front and Rear) 0.3 m 1 ft Dimensions (Including Service Areas) Height 1m 3.3 ft Width 0.8 m 2.5 ft Depth 1.9 m 6.3 ft Power—150 W Power Supply Nominal Output Voltages Disk spinup interval 1–4 DIGITAL StorageWorks 16-Bit Pedestals +5 V dc @ 8.4 A +12 V dc @ 9.0 A 4 second (minimum) Introducing the StorageWorks Pedestal StorageWorks Building Blocks (SBBs) The following factors determine the compatible storage devices: • The individual SBBs that the SCSI controller supports (see the controller release notes). • The combinations of SBBs on the same SCSI bus that the SCSI controller supports (see the controller release notes). • You cannot install tape storage devices with a loader (for example, the TLZ7L–VA cartridge tape drive) in a pedestal. Figure 1–5 Typical 5.25-Inch SBB Figure 1–4 Typical 3.5-Inch SBB CXO-4379A-MC CXO-4380A-MC DIGITAL StorageWorks 16-Bit Pedestals 1–5 Introducing the StorageWorks Pedestal Power The power distribution unit distributes ac power to shelf SBB power supplies and other pedestals. The ac distribution unit has the following features: • Universal ac input (100–240 V ac, 50–60 Hz) • Switch controlled ac outputs Two 2.0 amp shelf power cords (see Figure 1–8) One 4.0 amp power cord for second pedestal (see Figure 1–9) • User-selected, country-specific power cords (see Table 1–3) Figure 1–7 Power Distribution Unit—Rear View Figure 1–6 Typical 3.5-Inch SBB AC INPUT RECEPTACLE 0 I SECOND UNIT POWER CORD CXO-4418A-MC POWER SWITCH SHELF POWER CORDS CXO-4417A-MC ___________________ Note _________________________ For proper operation of a pedestal, you must have either one of the recommended country-specific power cords listed in Table 1–3 or an equivalent. ____________________________________________________________________ 1–6 DIGITAL StorageWorks 16-Bit Pedestals Introducing the StorageWorks Pedestal Table 1–3 Recommended Country-Specific AC Power Cords V ac A Connector Type M Ft Part No. Australia Country 250 10 IEC 320 C13, C14 AS3112-1981 Plug Type 2.5 8.2 BN19H-2E Central Europe 250 10 IEC 320 C13, C14 CEE 7/7 (Schuko) 2.5 8.2 BN19C-2E Denmark 250 10 IEC 320 C13, C14 Afsnit 107 2.5 8.2 BN19K-2E India 250 10 IEC 320 C13, C14 BS 546 2.5 8.2 BN19S-2E Ireland 250 10 IEC 320 C13, C14 BS 1363 2.5 8.2 BN19A-2E Israel 250 10 IEC 320 C13, C14 SI 32 2.5 8.2 BN18L-2E Italy 250 10 IEC 320 C13, C14 CEI 213-16/VII 2.5 8.2 BN19M-2E Japan 125 15 IEC 320 C13, C14 NEMA 5-15 3.0 9.8 BN27S-03 New Zealand 250 10 IEC 320 C13, C14 AS3112-1981 2.5 8.2 BN19H-2E South Africa 250 10 IEC 320 C13, C14 BS 546 2.5 8.2 BN19S-2E Switzerland 250 10 IEC 320 C13, C14 SEV 1011 2.5 8.2 E0-BN19H-2E United Kingdom 250 10 IEC 320 C13, C14 BS 1363 2.5 8.2 BN19A-2E United States 125 15 IEC 320 C13, C14 NEMA 5-15 3.0 9.8 BN27S-03 Figure 1–9 Power Distribution Unit—Rear View Figure 1–8 Typical 3.5-Inch SBB AC INPUT RECEPTACLE 0 I SECOND UNIT POWER CORD CXO-4418A-MC POWER SWITCH SHELF POWER CORDS CXO-4417A-MC DIGITAL StorageWorks 16-Bit Pedestals 1–7 Introducing the StorageWorks Pedestal Cooling The two dual speed, 7200 RPM blower assemblies on the back of the SBB shelves cool the pedestal by moving air from the front of the pedestal, through the SBBs and the shelf, and out the rear. The air flow control baffles in the base and in the top prevents the exhaust air from circulating within the pedestal. DIGITAL recommends you replace a defective blower immediately, even though one blower provides enough air flow to keep the devices operating. A safety screw and two “press-to-release” mounting tabs secure each blower assembly to the shelf. Figure 1–10 Blower Assemblies Locations BLOWER ASSEMBLY CXO-4414A-MC 1–8 DIGITAL StorageWorks 16-Bit Pedestals 2 Installing a Pedestal This chapter describes the procedures for installing a pedestal. Subjects include planning the installation; initial installation procedures; storage device security; replacing storage devices; testing the pedestal; connecting the SCSI cables; and connecting the power cables. Planning the Installation Planning the installation involves the following processes: • Determining the approved installation environment (commercial or home) • Selecting an area that provides sufficient space • Considering the SCSI bus restrictions The location of the pedestal depends upon the SBBs used. The pedestal and shelves are Class B devices, and can be installed in a home environment. However, installing a Class A certified device, such as an RRD45-VA CD-ROM restricts installation to a commercial or office environment. The device certification label (see Figure 2–1) lists the device certification. Figure 2–1 Typical Device Certification Label CXO-5000A-PH • All SBBs meet FCC Class A standards for use in a commercial environment. • You can install FCC Class B SBBs in a home environment. • Use in a home environment requires that all SBBs be FCC Class B certified. The user is responsible for installing the pedestal in the approved environment. DIGITAL StorageWorks 16-Bit Pedestals 2–1 Installing a Pedestal Selecting the Installation Area As shown in Figure 2–2, the pedestal requires an area: • 1.9 m (6.3 ft) deep • 0.8 m (2.5 ft) wide • 1 m (3.3 ft) high Figure 2–2 Pedestal Installation Dimensions 0.8 m (2.5 ft) 1m (3.3 ft) 1.9 m (6.3 ft) CXO-4406A-MC In addition to the space requirements, you should also consider the following factors: • The locations of SCSI controller or host. • The maximum bus length. • The length of the SCSI bus cable. • The routing of the SCSI bus cable. • The location of the ac power source 2–2 DIGITAL StorageWorks 16-Bit Pedestals Installing a Pedestal SCSI Cables Selecting a SCSI cable requires you to: • Determine the maximum cable length based upon the: Bus type (single ended or differential) bus speed • Shelf connectors Refer to the following publications for detailed information about the SCSI buses and cables. • StorageWorks Solutions BA356–SB 16-Bit Shelf and SBB User’s Guide • StorageWorks Solutions Shelf and SBB User’s Guide (8-bit shelves) Once you have selected the cable you must determine the best path for the cable from the controller to the pedestal. In some cases it may be necessary to relocate the pedestal. __________________ Note__________________________ Remember that as much as 1 m (3 ft) of the SCSI cable can be within the pedestal. ____________________________________________________________________ Installing the SCSI Cables The SCSI cables connect to the SBB shelf I/O module connectors. You can install the cable either through the rear of the pedestal (the primary path, see Figure 2–3) or through the side of the bezel (the alternate path, see Figure 2–4). The cable path you use depends on the SCSI bus cable length. The primary path is longer and requires you to insert the cables into the air flow baffle in the top. Figure 2–3 SCSI Cables—Primary Path JA1 JB1 To host CXO4374A DIGITAL StorageWorks 16-Bit Pedestals 2–3 Installing a Pedestal The alternate path is approximately 1 m (3.3 ft) shorter. To use it, remove one of the bezel clips from the top of the front bezel. Figure 2–4 SCSI Cables—Alternate Path 0.3 m (1 ft) 0.6 m (2 ft) .4 m (1.3 ft) CXO-4404A-MC The SCSI cables attach to one the I/O shown in Figure 2–5, Figure 2–6, or Figure 2–7. Figure 2–6 16-Bit SBB Shelf I/O Module Figure 2–5 16-Bit Expander I/O Module ON 1 2 3 4 5 6 7 Channel A connector Upper mounting tab Channel B connector Lower mounting tab CXO5710A JA1 JB1 CXO-4415A-MC 2–4 DIGITAL StorageWorks 16-Bit Pedestals Installing a Pedestal Figure 2–7 8-Bit SBB Shelf I/O Module CXO-4821A-MC Installing the Power Cord As shown in Figure 2–8, the pedestal input power cable connects to the rear of the distribution unit. Figure 2–8 Power Cord Routing INPUT POWER CORD TO SECOND UNIT TO AC OUTLET INPUT AC POWER CORD CXO-4375A-MC DIGITAL StorageWorks 16-Bit Pedestals 2–5 Installing a Pedestal Installing SBBs The basic rules for installing SBBs are as follows: • You always install the primary ac power supply SBB in the bottom shelf slot, Slot 7. • You can install either a redundant power supply, or a storage SBB in Slot 6. • You can install storage device SBBs in any of the remaining slots (Slots 0 through 5). ___________________ Note _________________________ To increase stability, DIGITAL recommends that you install SBBs starting at the bottom of the pedestal (slot 6). ____________________________________________________________________ The combinations of the SBB guides, shelf slots, and backplane connectors preclude installing an SBB incorrectly. Each 3.5-inch SBB occupies one shelf slot; each 5.25-inch SBB occupies three shelf slots. Removing or replacing any SBB requires that you remove the front bezel. You may need a key to unlock the bezel. When you insert an SBB in a slot and fully seat it, the two tabs on the front panel expand and engage the shelf, thereby securely mounting the SBB. To remove an SBB you press the two tabs in and remove the SBB. Checking Pedestal Operation After you assemble the pedestal you must test its basic functionality. __________________ Caution _______________________ You should complete the pedestal test before connecting the SCSI cable to the host or SCSI controller to avoid causing SCSI bus problems. ____________________________________________________________________ Table 2–4 To Check Pedestal Operation 1. Open the front door and turn on the pedestal power. Observe the status light emitting diodes (LEDs) on the shelf power supply in Slot 7 (bottom slot). • The power supply status LED (on the right) lights immediately. • The shelf status LED (on the left) is on when both blowers are at the proper speed. SHELF STATUS LED POWER SUPPLY STATUS LED CXO-4377A-MC 2–6 DIGITAL StorageWorks 16-Bit Pedestals Installing a Pedestal 2. Observe the LEDs on each SBB. • The green activity LEDs initially flash on, and then go OFF • The amber fault LEDs should remain OFF.. ACTIVITY LED (GREEN) FAULT LED (AMBER) CXO-4378A-MC 3. Once the initial “spin-up” is complete, the device activity LEDs should flash only when the controller is addressing the device 4. Turn off the pedestal power before connecting controller SCSI bus cable. Connecting the Controller The final phase of the installation is connecting the pedestal to the SCSI controller. _________________ Caution ________________________ Connecting SCSI cables with power applied to either the pedestal or the controller can generate signals that will “hang” the SCSI bus. Therefore, always turn off the power on the pedestal and the host controller before connecting the host SCSI bus cable. ____________________________________________________________________ Once you have connected the pedestal to the controller, apply power to the pedestal and the controller, and use the SCSI controller to test all devices for proper operation. Moving the Pedestal It may be necessary to move the pedestal for servicing. The rules for moving a pedestal are as follows: ________________ WARNING _______________________ Use two people to move pedestal since it weighs more than 18 kilograms (40 pounds) with SBBs and power supplies installed. ____________________________________________________________________ 1. Disable the SCSI bus at the controller. _________________ Caution ________________________ Always turn the pedestal off and allow the devices allowed to spin down before moving the pedestal. This will prevent damaging the storage devices. ____________________________________________________________________ 1. When necessary, disconnect the pedestal power cord and the SCSI cables. 2. Do not lift the pedestal by the bezel or the door. DIGITAL StorageWorks 16-Bit Pedestals 2–7 3 Operating a Pedestal This chapter describes the procedures for operating a pedestal to include detecting, isolating, and eliminating malfunctions. This description does not include configuring the RAID subsystem. The controller documentation includes the complete a complete description of these procedures. The pedestal has only one component that can fail—the ac distribution unit. All the replaceable components are part of the shelf and the associated SBBs. It is possible, but unlikely, that there would be a failure of the SCSI cables or the ac power cords. The following sections describe error indications and the possible causes. For a detailed description of possible problems and recommended solutions, please refer to your shelf user’s guide. Operational Status LEDs on the SBB bezels indicate the operational status of the shelf power and cooling and the storage device SBBs. Open the front door for a better view of the LEDs. For a detailed description of the SBB status LED, refer to either the SBB User’s Guide (8-bit SBBs) or the 16-Bit SBB User’s Guide. Table 3–1 Status LEDs To determine the status of a power supply or the blowers 1. Observer the power supply status LEDs 2. When the ac power is missing, or either the +5 V dc or the +12 V dc power supply voltages are incorrect, both the shelf status and the power status LEDs are off. 3. When either blower assembly fails, the shelf status LED on the power SBB is off and the power supply status LED is on. 4. When there is an error indication, complete the procedures in Table 3–4. SHELF STATUS LED POWER SUPPLY STATUS LED CXO-4377A-MC DIGITAL StorageWorks 16-Bit Pedestals 3–1 Operating a Pedestal ___________________ Note _________________________ The LED positions and functions are identical for both the 3.5-inch and the 5.25-inch SBBs. ____________________________________________________________________ Table 3–2 Status LEDs (Continued) To determine the status of the SBBs 1. Observe the individual SBB green activity LED and the amber fault LED. 2. Normally the green activity LED is flashing the and amber fault LED is off. 3. When there is an error indication complete the procedures in 4. The power supply certification label lists the power supply model number and power rating. ACTIVITY LED (GREEN) FAULT LED (AMBER) CXO-4378A-MC CXO-4380A-MC Replacing SBBs and Power Supplies The procedure for replacing either a storage device SBB or a power supply is almost identical. Complete the procedure in Table 3–3 to replace an SBB. To replace a power supply, complete the procedures in Table 3–4. __________________ Caution _______________________ The SCSI controller determines the correct procedure for removing and replacing (“swapping”) an SBB. Check your SCSI controller documentation to determine the procedures supported. Unless the controller supports removing or installing an SBB while the SCSI bus is active, a hot swap, you may corrupt or lose the data. DIGITAL controllers, such as the HSZ-series, have switches for deactivating (quiescing) individual buses. Quiescing the bus without turning the SBB shelf power off to replace an SBB is a warm swap. ____________________________________________________________________ 3–2 DIGITAL StorageWorks 16-Bit Pedestals Operating a Pedestal Table 3–3 To Replace an SBB 1. If your controller supports hot swap go to Step 2. If your controller does not support hot swap, quiesce the SCSI bus. If you cannot quiesce the SCSI bus, turn the controller off. 2. Open the door and unlock the bezel. 3. Grasp the bezel at the bottom. Rotate the bezel out and away until the locking tabs disengage the base. 4. Press the SBB mounting tabs together and remove the defective SBB. CXO-4376A-MC 5. Check the SBB label on the front of both SBBs and verify that items identical. 1 2 M, N, R, S, T, and U are RZ29B-VA 4.3 GB 3 LUN # 4 ID # 5 CH # 9 10 F10 N 6 8 N/W 7 CXO-5370A-MC Transcribe the item O, P, and Q information to the replacement SBB label. 6. Insert the replacement SBB and press it firmly into the slot until it is fully seated and the bezel mounting tabs engage the shelf. 7. Carefully engage the bezel bottom locking tabs with the base. 8. Carefully rotate the top of the bezel in towards the pedestal until it mates with the top. 9. Firmly seat the bezel and ensure that the top and bottom of the bezel are the same distance from the edge of the shelf. DIGITAL StorageWorks 16-Bit Pedestals 3–3 Operating a Pedestal 10. Lock the bezel. 11. Apply power, start the SCSI bus, and check that the pedestal is operating correctly. 12. Check the SBB status LEDs for proper operation. __________________ Caution _______________________ StorageWorks ac power supplies are available in wide range of power ratings (watts). You can replace a lower rated supply with a higher rated supply. For example, you can replace a 150 W supply with a 180 W supply. The reverse is not true. DIGITAL does support replacing a higher rated supply with a lower rated supply. The power supply certification label lists the power supply model number and power rating. ____________________________________________________________________ Table 3–4 To Replace a Power Supply 1. Turn the pedestal power off. Open the door and unlock the bezel. 2. Grasp the bezel at the bottom. Rotate the bezel out and away until the locking tabs disengage the base. 3. Disconnect the shelf power cords. 4. Press the power supply bezel mounting tabs together and remove the power supply. 5. Observe the power supply certification label on both the defective and replacement power supply and ensure that they are the same model. 6. Install the replacement power SBB. 7. Connect the shelf power cord. 8. Carefully engage the bezel bottom locking tabs with the base. 9. Carefully rotate the top of the bezel in towards the pedestal until it mates with the top. 10. Firmly seat the bezel and ensure that the top and bottom of the bezel are the same distance from the edge of the shelf. 11. Lock the bezel. 12. Apply power, start the SCSI bus, and check that the pedestal is operating correctly. 13. Turn on the SCSI bus. 3–4 DIGITAL StorageWorks 16-Bit Pedestals Operating a Pedestal Replacing a Blower Assembly Failure of either blower assembly turns OFF the power supply green shelf status LED; the green power supply status LED remains ON. Complete the following procedure to replace a defective blower: Table 3–5 To Replace a Blower Assembly 1. Turn off power to the pedestal. 2. Unlock the rear bezel. Grasp the rear bezel at the bottom. Rotate the bezel out and away until the locking tabs disengage the base. 3. Locate the blower that is not running and remove the safety screw. Safety screw Warning label Locking tab (2) Connector CXO4405A 4. Press in on the two mounting tabs and remove the blower assembly. 5. Align the connector guide on the replacement blower assembly with the connector on the shelf. 6. Push in on the blower assembly to fully seat it and the locking tabs engage the shelf. 7. Install the safety screw. 8. Carefully engage the bezel bottom locking tabs with the base. 9. Carefully rotate the top of the bezel in towards the pedestal until it mates with the top. 10. Firmly seat the bezel and ensure that the top and bottom of the bezel are the same distance from the edge of the shelf. 11. Lock the bezel. 12. Turn on the power. The blower begins operating and both shelf status LEDs are on. DIGITAL StorageWorks 16-Bit Pedestals 3–5 Operating a Pedestal Disassembling a Pedestal Almost all maintenance procedures require you to remove and replace the pedestal bezel. The procedure in Table 3–6 is the same whether you are removing the front or rear bezel. Table 3–6 Removing and Installing a Bezel 1. Open the door and unlock the bezel. 2. Turn the bus off either at the controller or by turning off the pedestal power. 3. Grasp the bezel at the top. Rotate the bezel out and down from the pedestal until the bottom locking tabs disengage from the base. 4. Once you have removed the bezel, you can remove SBBs, install cables, or complete all other maintenance procedures 5. Carefully engage the bezel bottom locking tabs with the base. 6. Carefully rotate the top of the bezel in towards the pedestal until it mates with the top. 7. Firmly seat the bezel and ensure that the top and bottom of the bezel are the same distance from the edge of the shelf. 8. Lock the bezel. 9. Apply power, start the SCSI bus, and check that the pedestal is operating correctly. 10. Close the front door. Table 3–7 To Replace a Shelf 1. Turn off power for both the pedestal and the controller. 2. Open the pedestal door and unlock the bezel. 3. Grasp the bezel at the top. Rotate the bezel out and down from the pedestal at the bottom of the bezel disengage from the base. 4. Disconnect all power cords: 5. Record the slot location of each SBB. 6. Remove all SBBs. 7. Disconnect the SCSI cables. ___________________ Note _________________________ The shelf fits tightly into the base and top. You must pull hard to remove the top from the shelf or the shelf from the base. ____________________________________________________________________ 8. Hold the shelf in place and lift up on the front of the top to disengage it from the shelf. 9. Hold the base in place and lift up on the shelf to disengage it from the base. 10. Carefully align the replacement shelf mounting slots with the base dimple strips at the REAR of the base and fully seat the shelf. 11. Carefully align the dimple strips at the rear of the top with the shelf mounting slots and fully seat it. 12. Connect the SCSI cables to the shelf. 13. Install the shelf power supply. 14. Install the SBBs. 15. Connect the power cords. 3–6 DIGITAL StorageWorks 16-Bit Pedestals Operating a Pedestal 16. Install the front and rear bezel. 17. Apply power and check pedestal operation. 18. Start the SCSI controller and check that both the controller and the SBBs are operating properly. DIGITAL StorageWorks 16-Bit Pedestals 3–7 Glossary ac distribution The method of distributing ac power in a cabinet. ac distribution unit The deskside expansion pedestal ac input device. ac power supply See shelf power supply. adapter See SCSI signal bus converter. backplane The electronic printed circuit board mounted in the rear of the shelf. This board contains the SBB, power supply, and terminator connectors. blower assembly An airflow device mounted in a StorageWorks shelf. building block shelf See SBB shelf. carrier See modular carrier. certified device A storage device that has been tested and found to be in compliance with either an FCC or a CE certification standard. channel Another term for a SCSI bus. cold swap Glossary 1 Glossary A method of device replacement that requires that power be removed from one or more shelves in a cabinet thereby affecting other devices therein. User applications that are not dependent upon the devices being swapped continue to function. Use this method when you cannot use either the "warm swap” or the “hot swap” method. Usually, you use this method only when installing or upgrading a StorageWorks subsystem. See also warm swap and hot swap. compatible device A storage device that has been tested in a specific enclosure and found to be compatible. controller A hardware–firmware device that manages communications on behalf of host systems over the SCSI bus to devices, such as the HSC–series, HSJ–series, and HSZ–series controllers. Controllers typically differ by the host interface type and provide functions beyond those the devices support. controller shelf A StorageWorks shelf containing a maximum of two controller with cache memory modules and two shelf power supplies. For example, a BA350–M series shelf. CE-Mark A European Economic Community (EEC) certification label that identifies electronic devices authorized for sale within member nations. CE-Mark Class A Similar to, but more stringent than the FCC Class A certification, this certification label appears on electronic devices that can only be used in a commercial environment. You can also use a CE-Mark certified device in the United States. CE-Mark Class B Similar to, but more stringent than the FCC Class B certification, this certification label appears on electronic devices that can only be used in either a home or a commercial environment. You can also use a CE-Mark certified device in the United States. daisy chain A common method of connecting ac power or SCSI buses from the source through a shelf or enclosure to another shelf or enclosure. dc power supply See shelf power supply. deskside expansion unit An enclosure, commonly referred to as a pedestal, that houses a StorageWorks shelf in a vertical position. You can assemble a pedestal with a pedestal kit, and a user supplied SBB shelf, storage SBBs, and an ac power cord. The factors that determine the number of devices you can use, the SCSI buses supported, and the pedestal location are the SBB shelf type, the storage SBBs, and the SCSI controller. disk A storage device supporting random access to fixed size blocks of data. 2 Glossary- Glossary dual power configuration See redundant power configuration. DWZZB The 16-bit single ended compatible SCSI bus signal converter. See also SCSI bus signal converter. electromagnetic interference See EMI. electrostatic discharge See ESD. EMI Electromagnetic interference. The impairment of a signal by an electromagnetic disturbance. ESD Electrostatic discharge is the discharge of a potentially harmful static electric voltage as a result of improper grounding. FCC Federal Communications Commission. The federal agency responsible for establishing standards and approving electronic devices within the United States. FCC Class B This certification label appears on electronic devices that can only be used in either a home or a commercial environment within the United States. . A CE-Mark certified device can be used in the United States in the same environment as the equivalent FCC certification.. host The primary or controlling computer (in a multiple computer network) to which you attach storage systems. host computer See host. hot swap A method of device replacement whereby the complete system remains on-line and active during device removal or insertion. The device being removed or inserted is the only device that cannot perform operations during this process. See also cold swap and warm swap. IEC International Electrotechnical Committee. An organization that develops and publishes electronic and mechanical standards. initiator A SCSI device (usually a host system) that requests by another SCSI device (a target) to perform an operation. Glossary- 3 Glossary International Electrotechnical Committee See IEC. logical bus A single ended, physical bus connected to a differential, physical bus by a SCSI bus signal converter. logical units A group of devices addressable as a virtual unit. modular carrier The StorageWorks compatible plastic container in which you can install storage devices or power supplies to form SBBs. Modular carriers are available in both 3.5-inch and 5.25-inch form-factors. pedestal The common name for a deskside expansion unit. See also deskside expansion unit. pedestal kit A kit for converting a customer-supplied StorageWorks shelf into a deskside expansion unit or pedestal. physical bus Two SCSI terminators separated by cables, connectors, and backplane circuitry. port (1) A logical route for data in and out of a controller. A port can contain one or more channels, all of which contain the same type data. (2) The hardware and software that connects a host controller to a CI, SCSI, or SDI bus. qualified device See supported device. quiesce To make a bus inactive or dormant. For example, you must quiesce SCSI bus operations when warm swapping an SBB. quiescent Inactive or still, dormant. radio frequency interference See RFI. RAID Redundant array of independent disks. A set of storage techniques devised to increase the performance and availability of a storage subsystem. redundant power configuration 4 Glossary- Glossary A capability of StorageWorks cabinet and shelves to ensure there is no single point of power failure. (1) For a cabinet two ac power sources and two CDUs distributed primary and redundant ac power to shelf power supplies. (2) For a shelf, the primary and redundant shelf SBB power supplies ensure the dc power is available even when there is a failure of one supply, one ac source, or one CDU. Implementing the redundant power configuration provides protection against the loss or corruption of data. RFI Radio frequency interference. The impairment of a signal by an unwanted radio signal or radio disturbance. SBB StorageWorks building block. The basic building block of the product line. Any device conforming to shelf mechanical and electrical standards installed in either a 3.5-inch or 5.25-inch carrier is considered to be an SBB, whether it be a storage device, a power supply, or other device. SBB shelf The common name for a StorageWorks storage device shelf. This shelf also contains shelf power supply SBBs. SCSI Small computer system interface. This ANSI interface defines the physical and electrical parameters of a parallel I/O bus used to connect computers and a maximum of seven devices. The StorageWorks subsystem implementation uses SCSI–2, for the synchronous transfer of 8-bit data at rates of up to 10 MB/s. SCSI bus signal converter Sometimes referred to as an adapter. (1) A connecting device that permits the attachment of accessories or provides the capability to mount or link units. (2) The device that connects a 16-bit, differential SCSI bus operating in the 8-bit mode to an 8-bit, single ended SCSI bus. (3) The device that connects a 16-bit, differential SCSI bus operating in the 8-bit mode to an 16-bit, single ended SCSI bus. SCSI busing connection A connection in the SCSI bus between two terminators such as the SBB shelf SCSI input connector. SCSI device A host computer adapter, a peripheral controller, or an intelligent peripheral that can be attached to the SCSI bus. SCSI device ID The bit-significant representation of the SCSI addressing referring to one of the signal lines numbered 0 through 7 for an 8-bit bus or 0 through 15 for a 16-bit bus. Also referred to as “target ID”. Glossary- 5 Glossary SCSI device-side device address The 8 (0 through 7) or 16 (0 through 15) device addresses (target IDs) assigned to the SCSI controller and the devices it controls. See also SCSI host-side device address. SCSI end-bus position The physical location of a controller, a SCSI bus controller, or a device that contains the bus terminator. SCSI host-side device address The eight device addresses (target IDs) assigned to the host device and the SCSI controllers and the devices it controls. See also SCSI device-side device address. SCSI midbus position The physical location of a controller or a device that the SCSI bus passes through enroute to the controller or device that contains the SCSI bus termination. SCSI port (1) Software: The channel that controls communications to and from a specific SCSI bus in the system. (2) Hardware: The name of the logical socket at the back of the system unit to which a SCSI device is connected. SCSI stubbing connection A connection in the SCSI bus path between a terminator and a connector, such as a trilink connector, that is used to place a controller in the midbus position. SCSI–A cable A 50-conductor (25 twisted pair) cable used for single ended, SCSI–2 bus connections. SCSI–P cable A 68-conductor (34 twisted pairs) cable used for differential bus connections. shelf power supply The power supply that provides +5 V dc and +12 V dc to the StorageWorks shelves. These supplies can be either ac input (120 V ac) or dc (48 V dc). signal converter See SCSI bus signal converter. single ended SCSI bus A bus in which each signal’s logic level is determined by the voltage of a single wire in relation to ground. Small Computer System Interface See SCSI. split bus 6 Glossary- Glossary A single SBB shelf SCSI bus that is configured as two individual buses (a four-device bus and a three-device bus) is commonly referred to as a split bus. spin down The process that begins when power is removed from a storage device and data transfer halts, and ends when the device is stopped and can be moved. In the case of disk drives, the heads are retracted and the media is stopped. spin up The process that begins when power is applied to a storage device, and ends when the device is determined to be operational and ready for data transfer operations. storage array An integrated set of storage devices. storage array subsystem See storage subsystem. storage sets A grouping of disk drives that make up a new distinct container. storage subsystem The controllers, storage devices, shelves, cables, and power supplies that form a mass storage subsystem. StorageWorks The DIGITAL set of enclosure products that allows customers to design and configure their own storage subsystem. Components include power, packaging, and interconnections in a StorageWorks shelf. SBBs and array controllers are integrated therein to form storage subsystems. System-level enclosures to house the shelves and standard mounting devices for SBBs are also included. StorageWorks building block See SBB. subsystem array strategy A strategy, including packaging, devices, and controllers, that provides an integrated storage subsystem solution. supported device (1) A device that has been fully evaluated in an “approved” StorageWorks configuration (that is, shelf, cabinet, power supply, cabling, and so forth) and is in complete compliance with countryspecific standards (for example, FCC, CE-Mark, CSA, TÜV, VDE, and so forth) and with all DIGITAL standards. (2) A device supported by a controller or host operating system. tape A storage device supporting sequential access to variable sized data records. tape controller See controller. Glossary- 7 Glossary target A SCSI device that performs an operation requested by an initiator. target ID See SCSI device ID. UL Underwriters Laboratories. An organization that tests and certifies electrical devices. Underwriters Laboratories See UL. universal ac input power supply See shelf power supply. warm swap A method of device replacement whereby the complete system remains on-line during device removal or insertion. The system bus may be halted for a brief period of time, during device insertion or removal. No booting or loading of code is permitted except on the device being inserted. User applications that are not dependent upon the devices on the “affected SCSI bus” are not noticeably impacted. See also cold swap and hot swap. 8 Glossary-
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies