Digital PDFs
Documents
Guest
Register
Log In
EK-2100A-UP-A02
January 1996
76 pages
Original
0.9MB
view
download
Document:
AlphaServer 2100 and 2100 RM Upgrade to AlphaServer 2100A
Order Number:
EK-2100A-UP
Revision:
A02
Pages:
76
Original Filename:
OCR Text
AlphaServer 2100 and 2100 RM Upgrade to AlphaServer 2100A Part Number: EK-2100A-UP. A02 Digital Equipment Corporation Maynard, Massachusetts January 1996 Revised, May 1966 Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. Possession, use, or copying of the software described in this publication is authorized only pursuant to a valid written license from Digital or an authorized sublicensor. © Digital Equipment Corporation 1996. All rights reserved. The postpaid Reader's Comments form at the end of this document requests your critical evaluation to assist in preparing future documentation. The following are trademarks of Digital Equipment Corporation: AlphaServer, Digital, OpenVMS, StorageWorks, the AlphaGeneration logo, and the DIGITAL logo. The following are third-party trademarks: UNIX is a registered trademark, licensed exclusively by X/Open Company Ltd. Windows NT is a trademark of Microsoft, Inc. All other trademarks and registered trademarks are the property of their respective holders. Table of Contents TABLE OF CONTENTS PREFACE 1 UPGRADE REQUIREMENTS Hardware Requirements .........................................................................................1–1 Software Requirements............................................................................................1–2 OpenVMS and Windows NT..................................................................................1–2 Digital UNIX .........................................................................................................1–2 Recording Customized Configurations....................................................................1–3 StorageWorks RAID Array Subsystem Firmware .................................................1–3 Upgrade Process.......................................................................................................1–4 2 UPGRADING THE PEDESTAL HARDWARE Upgrade Process.....................................................................................................2–1 KFPEx-AA Hardware Upgrade Kit........................................................................2–2 Tools .........................................................................................................................2–2 Before You Begin.....................................................................................................2–3 iii Hardware Disassembly............................................................................................2–3 Step 1: Perform a power shutdown........................................................................2–3 Step 2: Remove power supplies.............................................................................2–4 Step 3: Unplug cables. ..........................................................................................2–4 Step 4: Remove system bus option modules...........................................................2–4 Step 5: Remove all internal cabling.......................................................................2–5 Step 6: Reassemble wave guides and assemble cables............................................2–5 Step 7: Remove system backplane.........................................................................2–6 Hardware Upgrade Procedure ................................................................................2–7 Step 1: Enable the FSL update switch on the new backplane. ................................2–7 Step 2: Install the new system backplane...............................................................2–9 Step 3: Recable the system. .................................................................................2–10 Step 4: Install the SCSI bulkhead cover............................................................... 2–17 Step 5: Reinstall system bus option modules........................................................2–17 Step 6: Affix EISA/PCI slot ID label...................................................................2–18 Step 7: Reinstall PCI and EISA Modules. ........................................................... 2–19 Step 8: Reinstall power supplies and right and left panels. .................................. 2–19 Next Steps...............................................................................................................2–19 3 UPGRADING THE RACKMOUNT HARDWARE Upgrade Process ....................................................................................................3–1 KFPEx-BA Hardware Upgrade Kit........................................................................3–2 Tools .........................................................................................................................3–3 Before You Begin.....................................................................................................3–3 Hardware Disassembly............................................................................................3–4 Step 1: Perform a power shutdown........................................................................3–4 Step 2: Unplug cables. ..........................................................................................3–4 Step 3: Stabilize the cabinet and extend the system out. ........................................3–5 Step 4: Access the PCI/EISA compartment and remove modules...........................3–7 Step 5: Access the system bus compartment and remove modules. ........................3–9 Step 6: Disconnect the power supplies.................................................................3–10 Step 7: Disconnect the fan power cable. ..............................................................3–11 Step 8: Separate the front and rear halves of the enclosure. ................................. 3–13 Step 9: Remove the system backplane. ................................................................3–17 iv Hardware Upgrade Procedure ..............................................................................3–18 Before You Begin.................................................................................................3–18 Step 1: Assemble the new PCI/EISA compartment. .............................................3–18 Step 2: Enable FSL update switch on new system bus backplane. ........................3–18 Step 3: Install the new system bus backplane.......................................................3–19 Step 4: Install the new PCI/EISA backplane........................................................3–19 Step 5: Remove and replace floppy cable and SCSI bus cable..............................3–20 Step 6: Reconnect the fan power cable.................................................................3–22 Step 7: Reinstall the rear half of the enclosure.....................................................3–23 Step 8: Reattach power cables. ............................................................................3–23 Step 9: Reinstall system bus modules. .................................................................3–24 Step 10: Reinstall PCI/EISA modules..................................................................3–25 Step 11: Reattach the PCI/EISA compartment cabling. .......................................3–25 Step 12: Secure the PCI/EISA compartment door................................................3–25 Step 13: Reconnect external cables and power supply..........................................3–25 Step 14: Re-label the system................................................................................3–26 Next Steps...............................................................................................................3–26 4 UPDATING SYSTEM FIRMWARE Upgrade Process.....................................................................................................4–1 AlphaServer 2100A Firmware Update Procedure..................................................4–2 Step 1: Clear SRM and ARC NVRAM..................................................................4–2 Step 2: Update the SRM and ARC ROM images. ..................................................4–2 Step 4: Exit the loadable firmware utility. .............................................................4–4 Step 5: Update the fail-safe loader ROM image. ....................................................4–4 Step 6: Disable the fail-safe loader update switch. .................................................4–5 Next Steps.................................................................................................................4–5 5 UPDATING CONFIGURATION DATA Upgrade Process.....................................................................................................5–1 Rebuilding EISA Configuration Data......................................................................5–2 Step 1: Start the ECU............................................................................................5–2 Step 2: Correct your configuration data. ................................................................5–2 Step 3: Step through the ECU dialog boxes. ..........................................................5–3 v Updating the StorageWorks RAID Controller Firmware......................................5–4 Step 1: Create a standalone configuration utility floppy.........................................5–4 Step 2: Run the utility to set controller parameters. ...............................................5–5 Step 3: Update the RAID controller firmware........................................................5–6 Next Steps.................................................................................................................5–7 6 COMPLETING THE UPGRADE Upgrade Process ....................................................................................................6–1 Installing Digital UNIX .........................................................................................6–1 Restoring Custom Configurations ..........................................................................6–2 vi Preface Introduction This document provides information for upgrading the following AlphaServer 2100 systems to AlphaServer 2100A systems: • AlphaServer 2100 system in BA740 pedestal enclosure • AlphaServer 2100 RM system in BA741 rackmount enclosure Audience This document is for service persons and self-maintenance customers who are responsible for managing and upgrading AlphaServer 2100 or AlphaServer 2100 RM systems. Organization of This Document Chapter 1 explains the prerequisites for the upgrade. Chapter 2 describes the hardware removal and replacement procedure for upgrading a pedestal system. Chapter 3 describes the hardware removal and replacement procedure for upgrading a rackmount system. Chapter 4 explains how to upgrade the system firmware. Chapter 5 contains instructions on updating your configuration data. Chapter 6 explains how to complete the upgrade. vii Conventions The following table lists conventions used in this guide. Convention lowercase Meaning Console commands are shown in lowercase. However, you can enter console commands in uppercase or lowercase. Warning Warnings contain information to prevent personal injury. Caution Cautions provide information to prevent damage to equipment or software. boot Console commands are shown in this special typeface. italic type Italic type in command syntax indicates a variable. 1 2 3… In some illustrations, a numbered callout labels a part of the illustration. In text, it refers to a labeled part of a corresponding illustration. Symbols Pay particular attention to the following warning in this document. Warning CPU and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before handling these modules. viii For More Information The following table lists reference documents for the hardware upgrade. Document Title Part Number AlphaServer 2100/2100RM Series Service Guide EK-KN450-SV AlphaServer 2100 Illustrated Parts Breakdown EK-SY450-IP AlphaServer 2100 Owner’s Guide EK-KN450-OP AlphaServer 2100 RM Installation/Owner’s Guide EK-KN450-RM ix 1 Upgrade Requirements This chapter provides a brief overview of the requirements for upgrading an AlphaServer 2100 or AlphaServer 2100 RM system to an AlphaServer 2100A system. Hardware Requirements Be sure to note the following hardware requirements before proceeding with the upgrade. • The AlphaServer 2100A has no onboard Ethernet. An option card is needed. The DE435-AA Ethernet card, cables, and installation instructions are included in this upgrade kit. • The onboard SCSI could be connected externally on the AlphaServer 2100 system, within the SCSI limitations. The AlphaServer 2100A requires an additional controller for external expansion. • The AlphaServer 2100 system has 8 EISA slots and 3 PCI slots; the AlphaServer 2100A has 3 EISA slots and 8 PCI slots. Customers who have more than 3 EISA options need to transfer the functionality to PCI. 1–1 Upgrade Requirements • The following options are not supported on the AlphaServer 2100A: DE422-SA DE425-AA PB2HA-SA PB2SX-AA PBXGA-nn • DEC EtherWORKS EISA TP/BNC EISA, 32 Bit, B. M., PC NIC EISA to Fast SCSI Host Adapter EISA Prestoserve NVRAM Option ZLXp-E1 8-Plane or 24-Plane Adapter Before reinstalling EISA and PCI modules, consult the AlphaServer 2100A Hardware Release Notes (EK-2100A-CL), included with this upgrade kit. The release notes provide configuration guidelines and restrictions to assure optimal operation of options in PCI slots. Software Requirements OpenVMS and Windows NT You must update systems running either OpenVMS or Windows NT to the minimum revision level listed below before you begin the hardware upgrade. The operating system CD-ROM is shipped with the upgrade kit. Consult the operating system installation/upgrade documents for instructions on updating the operating system. Operating System Minimum Revision Level OpenVMS V6.2-1H1 Microsoft Windows NT V3.51, plus Hardware Support Disk Digital UNIX Minimum Revision You must install the Digital UNIX operating system, V3.2D-2 or higher, after you complete the hardware and firmware upgrades. The operating system CD-ROM is shipped with the upgrade kit. Consult the operating system installation/upgrade documents for instructions. Operating System Minimum Revision Level Digital UNIX V3.2D-2 1–2 Upgrade Requirements Recording Customized Configurations Before you upgrade the hardware, be sure to record any customized configuration information stored in the AlphaServer 2100 system NVRAM. Once you upgrade the hardware, any such customizations will be lost. It is recommended that you record the following items, as well as any others particular to the system you are upgrading. Refer to the AlphaServer 2000/2100/2100A Firmware Reference Guide shipped with this upgrade kit. System password (set password) Action on power-up (auto_action) Boot flags (boot_osflags) Boot device (bootdef_dev) Console display device (set console) Operating system type (os_type) Power-up/diagnostic display message (ocp_text) Nvram script (edit nvram) Once you complete the upgrade and restore any customized configuration parameters, certain devices may appear differently in the AlphaServer 2100A show config or show device displays. For example, the boot device may be named differently in the new displays. StorageWorks RAID Array Subsystem Firmware If your system is configured with a StorageWorks RAID controller, you may need to update the RAID controller firmware. The AlphaServer 2100A system requires firmware version 2.16 for EISA controllers and version 2.36 for PCI controllers. If your controller firmware is earlier than these levels, use the V3.11 standalone configuration utility to update it. Perform the RAID firmware update after you upgrade the hardware and update the system firmware. The V3.11 standalone configuration utility is provided on the Firmware Update CD-ROM in this upgrade kit. Refer to Chapter 5 for instructions. 1–3 Upgrade Requirements Upgrade Process The upgrade should be done in the following order. 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. 1–4 2 Upgrading the Pedestal Hardware This chapter describes the procedure for upgrading the AlphaServer 2100 BA740 enclosure hardware. You should be at step 3 of the following upgrade process. _________________________ Caution ___________________________ Before you upgrade the hardware, you must update the OpenVMS or Windows NT operating system to the minimum revision level listed in Chapter 1. Otherwise, the upgraded hardware will not support the operating system. Do not install the new version of Digital UNIX at this time. ____________________________________________________________ Upgrade Process 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. 2–1 Upgrading the Pedestal Hardware KFPEx-AA Hardware Upgrade Kit There are three variants of the KFPEx-AA hardware upgrade kit, as follows: • KFPEA-AA Items listed below and Digital UNIX operating system • KFPEY-AA Items listed below and OpenVMS operating system • KFPEN-AA Items listed below and Windows NT operating system KFPEx-AA Kit Contents Part Number Quantity 2100A system backplane 54-24129-01 1 34-conductor floppy cable 17-04229-01 1 50-conductor SCSI cable, self terminated 17-04193-01 1 Cable clamp 12-15843-02 1 SCSI bulkhead plate 74-48601-01 1 Blank plates for PCI/EISA window 74-42440-01 4 ID label for PCI/EISA slots 36-41957-02 1 Ethernet card DE435-AA 1 Ethernet cable: Shielded, 15-position D-sub BNE4C-02 1 Software kit containing: QZ-00SAA-EW 1 CD-ROM (Customer Firmware Kit) Digital UNIX and OpenVMS ECU diskette Windows NT ECU diskette QZ-003AA-E8 AK-Q2CR*CA AK-PYCJ*CA Operating system kit (one of the following): QB-23CAA-SA QA-MT4AA-H8 QA-MT1AG-H8 1 1 1 Upgrade manual (this document) EK-2100A-UP 1 AlphaServer 2100A Hardware Documentation QZ-00TAA-GC Windows NT Digital UNIX OpenVMS Hardware Release Notes Owner’s Guide Firmware Reference Guide EK-2100A-CL EK-2100A-OP EK-AXPFW-RM 1 1 1 Tools The hardware upgrade requires a Number 2 Phillips screwdriver. A powered screwdriver is recommended. You may also need a 7/32 nut driver to disassemble the cable wave guides. 2–2 Upgrading the Pedestal Hardware Before You Begin • If the system is running OpenVMS or Windows NT, do not begin the hardware upgrade until you have updated the operating system to the level listed in Chapter 1. • The hardware upgrade takes about an hour. • Check the contents of the upgrade kit to make sure you have all the items you need. • It is recommended that you have the system IPB, Service Guide, or Service Help File on hand to verify component removal and replacement. • Remove and replace FRUs in the order listed in this chapter. • Keep all cables and modules unless otherwise directed. • Keep all screws that you remove. You will be reusing the screws. _________________________ Caution ___________________________ System modules are static sensitive. Use an antistatic mat and wrist strap when handling modules. ____________________________________________________________ Hardware Disassembly Step 1: Perform a power shutdown. A. Perform an orderly shutdown of the operating system, as described in the operating system documentation. B. Set the DC power switch on the operator control panel to “off.” If necessary, refer to the system Owner’s Guide for the location of switches and power cords. C. Shut off AC power by setting the AC On/Off switch on each power supply to (O). D. Unplug the AC power cord for each power supply. E. Remove the front door, the panel from the right side, and the panel from the left side, as illustrated in the system Owner’s Guide. Warning CPU and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before handling these modules. 2–3 Upgrading the Pedestal Hardware Step 2: Remove power supplies. Remove the power supplies. There are 3 screws per supply. Step 3: Unplug cables. A. Unplug all external cables at the I/O area on the rear of the enclosure. B. Unplug internal cables from all EISA and PCI modules at the left of the enclosure. Step 4: Remove system bus option modules. A. Remove and discard the standard I/O module. B. Remove EISA and PCI modules. C. Remove CPU and memory modules, plastic filler plates, and card cage divider. Set aside the 6-32 screws for the card cage divider for reuse. Figure 2-1: Removing System Bus Modules MA00869A 2–4 Upgrading the Pedestal Hardware Step 5: Remove all internal cabling. A. Disconnect all internal power cables and I/O cables that pass through the 2 wave guides. The cables include: OCP cable (1) Floppy cable (1) Embedded SCSI cables (2) Internal SCSI controller cable (1 to 4) Fan power cable (1) Internal StorageWorks power cable (1 or 2) __________________________ Note_____________________________ If SCSI controller cables are installed, mark them to ensure proper reconnection. ____________________________________________________________ B. Remove the wave guides from the enclosure. Withdraw all cables through the internal card cage wall. C. Remove the nuts from the wave guides (4 nuts in each guide) and separate the wave guides. Some systems have wave guides without nuts. D. Withdraw the following cables and discard: Embedded SCSI cables 17-03872-01 17-03873-01 Floppy cable 17-03871-01 Step 6: Reassemble wave guides and assemble cables. _________________________ Caution ___________________________ All ferrite suppressers must be oriented to the inside of the card cage, as shown in Figure 2-2. ____________________________________________________________ 2–5 Upgrading the Pedestal Hardware Figure 2-2: Orientation of Ferrite Suppressers on Wave Guide Assembly MA00895 A. Assemble the following cables into one of the wave guides: New floppy cable (17-04229-01) OCP cable Fan power cable Internal StorageWorks power cable B. Assemble the following cables into the other wave guide: New embedded SCSI cable (17-04203-01) All remaining SCSI controller cables. C. Tighten all nuts and set aside the wave guide assemblies for later installation. Step 7: Remove system backplane Unplug the cables from the system backplane, and remove the backplane. There are 13 screws. Set aside the screws. This completes the hardware disassembly. You are ready to upgrade the hardware, as described next. 2–6 Upgrading the Pedestal Hardware Hardware Upgrade Procedure __________________________ Note_____________________________ Unless otherwise specified, install components by reversing the steps in the disassembly procedure. ____________________________________________________________ Step 1: Enable the FSL update switch on the new backplane. A. Locate the 2 fail-safe loader (FSL) switches on the new system backplane. 2–7 Upgrading the Pedestal Hardware B. Make sure the FSL enable switch (top switch) is pushed to the left (disabled). C. Using a small implement, set the FSL update switch (bottom switch) to the right (enabled). This will allow writes to the FSL. You will be updating the FSL as part of the firmware update described in Chapter 4. __________________________ Note _____________________________ For systems with redundant power supplies, install jumper W1 on the new system backplane, as shown in Figure 2-3. ____________________________________________________________ Figure 2-3: FSL Switches and W1 Jumper Fail-Safe Loader Switches OFF ON FSL Enable FSL Console Update W1 Redundant Power Jumper Jumper Installed Jumper Not Installed MA00892A 2–8 Upgrading the Pedestal Hardware Step 2: Install the new system backplane. Install the AlphaServer 2100A system backplane (54-24129-01), using the 13 screws you set aside when you removed the AlphaServer 2100 backplane. _________________________ Caution ___________________________ The backplane must be correctly aligned in order for modules to operate. To ensure correct alignment, start the top center screw just enough to support the module but still allow it to move freely. Start the bottom left screw and the top left screw. Tighten the bottom left screw first (1) and the top left screw second (2) to ensure correct module alignment. Then insert and tighten the remaining screws. ____________________________________________________________ Figure 2-4: Installing AlphaServer 2100A Backplane 2 1 MA00870 2–9 Upgrading the Pedestal Hardware Step 3: Recable the system. A. Install the wave guide assembly that contains the power cables and floppy cable by threading the cables through the rear cutout in the internal card cage wall. Note the proper orientation of the wave guide assembly (Figure 2-2). Reconnect all of the power cables and the floppy cable to storage devices and fans. B. Install the wave guide assembly that contains all of the SCSI cables by threading the cables through the front cutout in the internal card cage wall. Reconnect all of the SCSI cables to the appropriate connectors on the new system backplane. Refer to the following illustrations: Figure 2-5: Reconnection: Fan/Removable Media Cable Figure 2-6: Reconnection: Internal StorageWorks Power Cable Figure 2-7: Reconnection: Floppy Cable Figure 2-8: Reconnection: Embedded SCSI Cable Figure 2-9: Reconnection: OCP Cable Figure 2-10: Reconnection: Remote I/O Cable 2–10 Upgrading the Pedestal Hardware Figure 2-5: Reconnection: Fan/Removable Media Cable MA00862A 2–11 Upgrading the Pedestal Hardware Figure 2-6: Reconnection: Internal StorageWorks Power Cable MA00863A 2–12 Upgrading the Pedestal Hardware Figure 2-7: Reconnection: Floppy Cable MA00860C __________________________ Note_____________________________ Be sure to use the new floppy cable (17-04229-01) for this procedure. The location of pin 1 on the floppy connector depends on the device manufacturer. Therefore, you may need to flip the cable in order for the floppy to work. ____________________________________________________________ 2–13 Upgrading the Pedestal Hardware Figure 2-8: Reconnection: Embedded SCSI Cable MA00876A __________________________ Note _____________________________ Be sure to use the new SCSI cable (17-04193-01) for this procedure. Ensure that the self-contained terminator is fully seated at the end of the cable if it is not connected to the StorageWorks backplane. ____________________________________________________________ 2–14 Upgrading the Pedestal Hardware Figure 2-9: Reconnection: OCP Cable MA00866A 2–15 Upgrading the Pedestal Hardware Figure 2-10: Reconnection: Remote I/O Cable MA00867A __________________________ Note _____________________________ Install the cable clamp supplied in the upgrade kit next to the ferrite suppresser. ____________________________________________________________ This completes the cabling procedures. 2–16 Upgrading the Pedestal Hardware Step 4: Install the SCSI bulkhead cover. Install the SCSI bulkhead cover (74-48601-01) over the cut-out in the system chassis from which the connector of the old SCSI cable was removed. Step 5: Reinstall system bus option modules. A. Reinstall the card cage divider with the 6-32 screws you set aside earlier. B. Reinstall CPUs and memories. C. Reinstall plastic filler modules. _________________________ Caution ___________________________ Empty slots adjacent to populated slots require a plastic filler to be inserted. ____________________________________________________________ 2–17 Upgrading the Pedestal Hardware Step 6: Affix EISA/PCI slot ID label. Be sure the top of the new label is aligned directly on top of the old label. Figure 2-11: Slot ID Label EISA 3 EISA 2 EISA 1 PCI 0 PCI 1 PCI 2 PCI 3 PCI 4 PCI 5 PCI 6 PCI 7 MA00875 2–18 Upgrading the Pedestal Hardware Step 7: Reinstall PCI and EISA Modules. A. Reinstall PCI and EISA modules. B. Reconnect external cables into PCI/EISA modules. The AlphaServer 2100A backplane has 3 EISA slots and 8 PCI slots. The kit provides extra blank plates for PCI/EISA windows, if needed. __________________________ Note_____________________________ Before reinstalling EISA and PCI modules, consult the AlphaServer 2100A Hardware Release Notes (EK-2100A-CL) shipped with this document. The release notes provide configuration guidelines and restrictions to assure optimal operation of options in PCI slots. ____________________________________________________________ Step 8: Reinstall power supplies and right and left panels. After reinstalling these components, attach the AC power cords to the power supplies. Next Steps This completes the hardware upgrade. You now need to update the system firmware, as described in Chapter 4. 2–19 3 Upgrading the Rackmount Hardware This chapter describes the procedure for upgrading the AlphaServer 2100 RM BA741 enclosure hardware. You should be at step 3 of the following upgrade process. _________________________ Caution ___________________________ Before you upgrade the hardware, you must update the OpenVMS or Windows NT operating system to the minimum revision level listed in Chapter 1. Otherwise, the upgraded hardware will not support the operating system. Do not install the new version of Digital UNIX at this time. ____________________________________________________________ Upgrade Process 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. 3–1 Upgrading the Rackmount Hardware KFPEx-BA Hardware Upgrade Kit There are three variants of the KFPEx-BA hardware upgrade kit, as follows: • KFPEA-BA Items listed below and Digital UNIX operating system • KFPEY-BA Items listed below and OpenVMS operating system • KFPEN-BA Items listed below and Windows NT operating system KFPEx-BA Kit Contents Part Number Quantity 2100A RM system bus backplane 2100A RM PCI/EISA backplane PCI/EISA compartment 34-conductor floppy cable 50-conductor SCSI cable, self terminated Ethernet card Ethernet cables: Shielded, 15-position D-sub 54-24281-01 54-24283-01 70-32504-01 17-04085-01 17-04203-01 DE435-AA BNE4C-02 1 1 1 1 1 1 1 SCSI bulkhead plate Blank plates for PCI/EISA window 74-48601-01 74-42440-01 Model number conversion label 36-15946-02 1 4 1 Model number ratings label 36-17674-00 1 Software kit containing: QZ-00SAA-EW QZ-003AA-E8 AK-Q2CR*CA AK-PYCJ*CA 1 QB-23CAA-SA QA-MT4AA-H8 QA-MT1AG-H8 1 1 1 Upgrade manual (this document) EK-2100A-UP AlphaServer 2100A RM Installation/Owner’s Guide EK-2100A-RM 1 1 AlphaServer 2100A Hardware Documentation QZ-00TAA-GC CD-ROM (Customer Firmware Kit) Digital UNIX and VMS ECU diskette Windows NT ECU diskette Operating system kit (one of the following): Windows NT Digital UNIX OpenVMS Hardware Release Notes Owner’s Guide Firmware Reference Guide 3–2 EK-2100A-CL EK-2100A-OP EK-AXPFW-RM 1 1 1 Upgrading the Rackmount Hardware Tools The hardware upgrade requires the following tools: • Number 2 Phillips screwdriver. A powered screwdriver is recommended. • Number 1 Phillips screwdriver (for removing/replacing mass storage compartment cover). • Flat-blade screwdriver, 1/2-inch wide • Torque device capable of up to 20 inch-pounds, with extension and Number 2 Phillips tip. Before You Begin • The hardware upgrade takes approximately one hour. • Check the contents of the upgrade kit to make sure you have all the items you need. • It is recommended that you have the system Service Guide or Service Help File on hand to verify component removal and replacement. • Remove and replace components in the order listed in this chapter. • Keep all cables and modules unless otherwise directed. • Keep all screws that you remove. You will be reusing the screws. _________________________ Caution ___________________________ System modules are static sensitive. Use an antistatic mat and wrist strap when handling modules. ____________________________________________________________ 3–3 Upgrading the Rackmount Hardware Hardware Disassembly Step 1: Perform a power shutdown. A. Perform an orderly shutdown of the operating system, as described in the operating system documentation. __________________________ Note _____________________________ It is recommended that you back up the system disk prior to system shutdown. ____________________________________________________________ B. Set the DC power switch on the operator control panel to “off.” If necessary, refer to the system Owner’s Guide for the location of switches and power cords. C. Unplug the AC power cord for each power supply. Warning CPU and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before handling these modules. Step 2: Unplug cables. A. Unplug all external cables at the I/O area on the rear of the enclosure. B. Remove the cable management bracket from the system chassis. 3–4 Upgrading the Rackmount Hardware Step 3: Stabilize the cabinet and extend the system out. _________________________Warning ___________________________ To prevent serious personal injury and equipment damage, stabilize the cabinet as described in the cabinet documentation. Each system chassis weighs 45.4 kg (100 lb.). On a cabinet with multiple systems, ensure that only one system is extended out of the cabinet at any one time. Do not extend more than one slide assembly at a time; cabinet instability may result. ____________________________________________________________ A. After you stabilize the cabinet, remove the front door and any bezels that prevent access to the system chassis, if applicable. B. Remove the front panel of the system chassis. Figure 3-1: Removing Front Panel MLO-012265 3–5 Upgrading the Rackmount Hardware C. Remove the 4 screws and extend the system out until it locks. Figure 3-2: Extending System Chassis MLO-012266 ________________________ Warning ___________________________ Under some circumstances, you may decide to completely remove a system from the cabinet for easier access to components. Use sufficient personnel and equipment to prevent personal injury and equipment damage. ____________________________________________________________ 3–6 Upgrading the Rackmount Hardware Step 4: Access the PCI/EISA compartment and remove modules. A. Loosen the 2 captive screws and open the PCI/EISA compartment door. Figure 3-3: Accessing the PCI/EISA Compartment MLO-012269 3–7 Upgrading the Rackmount Hardware B. Unplug all cables mounted to modules and route them through the egress openings in the card cage. Most cables are routed through the right egress (Figure 3-4). C. Remove PCI/EISA boards and blank plates for PCI/EISA windows. D. Remove and discard the standard I/O module (Figure 3-4). Figure 3-4: Removing Cables and Standard I/O Module MLO-012270 3–8 Upgrading the Rackmount Hardware Step 5: Access the system bus compartment and remove modules. A. Loosen the 2 captive screws and lift off the cover (Figure 3-5). B. Remove CPU and memory modules and all plastic fillers and set them aside for later reinstallation. Figure 3-5: Accessing System Bus Compartment MA01103 3–9 Upgrading the Rackmount Hardware Step 6: Disconnect the power supplies. A. Loosen the quarter-turn captive fasteners and open the bottom access door. B. Remove the power control cable and 12V cable from their connectors beneath the system backplane. C. Unscrew the 3V and 5V leads from the power bus bars. Figure 3-6: Removing Power Control Cables Power Control Cable 12V Cable MLO-012275 3–10 Upgrading the Rackmount Hardware Step 7: Disconnect the fan power cable. A. Using a Number 1 Phillips screwdriver, loosen the 6 quarter-turn fasteners and remove the cover to the mass storage compartment. Figure 3-7: Removing Top Cover MA01106 3–11 Upgrading the Rackmount Hardware B. Remove the fan assembly. Figure 3-8: Removing Fan Assembly MLO-011800 C. Disconnect the fan power cable from the top connector on the EISA/PCI backplane. Refer to Figure 3-18. 3–12 Upgrading the Rackmount Hardware Step 8: Separate the front and rear halves of the enclosure. A. Remove and set aside the 4 screws and pull the rear half of the enclosure back until it separates from the front. Figure 3-9: Separating Enclosure MA01104 3–13 Upgrading the Rackmount Hardware B. Lift off the rear half of the enclosure (Figure 3-10) and set it down as shown in Figure 3-12. Figure 3-10: Lifting Off Rear Half MA01105 ________________________ Warning ___________________________ The rear half of the enclosure is heavy. Take precautions in lifting it and setting it down. ____________________________________________________________ 3–14 Upgrading the Rackmount Hardware C. Remove the 4 power bus bars (6 screws each). Figure 3-11: Removing Power Bus Bars +3V Red Cable Brackets 5V RTN Black Cable Brackets Power Supply 12V Cable 3V RTN Black Cable Brackets +5V Red Cable Brackets Power Supply Control Cable MA01107 3–15 Upgrading the Rackmount Hardware D. Separate the system bus compartment from the PCI/EISA bus compartment. The 8 screws are accessible from inside the system bus card cage. Figure 3-12: Separating Compartments MLO-012277 E. Discard the PCI/EISA bus compartment, along with the EISA-based backplane. 3–16 Upgrading the Rackmount Hardware Step 9: Remove the system backplane. A. Remove and set aside the 9 screws. B. Remove and discard the system backplane. Figure 3-13: Removing the System Backplane 2 3/16 1 MLO-012279 This completes the hardware disassembly. You are ready to upgrade the hardware, as described next. 3–17 Upgrading the Rackmount Hardware Hardware Upgrade Procedure __________________________ Note _____________________________ Unless otherwise specified, you can install components by reversing the steps illustrated in the disassembly procedure. ____________________________________________________________ Before You Begin Before you begin the installation, check that the speaker cable is still engaged in the remote I/O board. Step 1: Assemble the new PCI/EISA compartment. Assemble the new PCI/EISA compartment (70-32504-01) and attach it to the system card cage, reusing the 8 screws you reserved earlier. Step 2: Enable FSL update switch on new system bus backplane. A. Locate the 2 fail-safe loader (FSL) switches on the new system bus backplane. B. Make sure the FSL enable switch (top switch) is pushed to the left (disabled). C. Using a small implement, set the FSL console update switch (bottom switch) to the right (enabled). This will allow writes to the FSL. You will be updating the FSL as part of the firmware update described in Chapter 4. Figure 3-14: FSL Update Switch Fail-Safe Loader Switches OFF ON FSL Enable FSL Console Update MLO-011752 3–18 Upgrading the Rackmount Hardware Step 3: Install the new system bus backplane To install the new system bus backplane (54-24281-01), see Figure 3-13, and start the screws labeled 1 and 2 in the illustration first. Then start the remaining screws, but do not tighten them until the PCI/EISA backplane is installed. Step 4: Install the new PCI/EISA backplane. A. Attach the PCI/EISA backplane (54-24283-01) to the system bus backplane, making sure the 2 boards are firmly engaged. B. Start the screws labeled 1 and 2 in the illustration first. Start the remaining screws, and then tighten all 9 screws in the PCI/EISA backplane. C. Tighten the 9 screws in the system bus backplane. Figure 3-15: Installing PCI/EISA Backplane 2 1 MLO-011790 3–19 Upgrading the Rackmount Hardware D. See Figure 3-11 to reattach the 4 power bus bars into the system bus backplane. Using the screws you reserved, torque to 9.0 inch-pounds +/– 20%. ________________________ Warning ___________________________ To prevent serious personal injury and equipment damage, attach the power bus bars as shown in Figure 3-11. ____________________________________________________________ Step 5: Remove and replace floppy cable and SCSI bus cable. A. Remove the 34-conductor floppy drive cable and install the new floppy drive cable from the PCI/EISA backplane to the floppy. __________________________ Note _____________________________ The RX26-AA floppy drive circuit board has a notch that is not the key for the cable. Orient the cable with the key away from the circuit board. ____________________________________________________________ Figure 3-16: Installing New Floppy Cable (17-04085-01) MLO-011748 3–20 Upgrading the Rackmount Hardware B. Remove the 50-conductor SCSI cable and install the new SCSI cable from the PCI/EISA backplane to each removable media device (up to 2) and to each hard drive (up to 2). Refer to Figure 3-17. Figure 3-17: Installing New SCSI Cable (17-04203-01) MLO-011759 3–21 Upgrading the Rackmount Hardware Step 6: Reconnect the fan power cable. A. Reconnect the fan power cable to the top connector on the PCI/EISA backplane. Figure 3-18: Reconnecting Fan Power Cable MLO-011760 B. Replace the fan assembly. C. Replace the top cover and tighten the 6 quarter-turn fasteners. 3–22 Upgrading the Rackmount Hardware Step 7: Reinstall the rear half of the enclosure. A. Feed the OCP cable, remote I/O cable, SCSI cable, and floppy cable back through the PCI/EISA compartment. Avoid pinching the cables. B. Insert and tighten the 4 screws to reattach the rear half of the enclosure to the chassis. Step 8: Reattach power cables. A. Open the bottom door and attach the power control cable and 12V cable to their connectors beneath the new system backplane. B. See Figure 3-19 to reattach the 3V and 5V leads to the power bus bars. The screws you reserved are torqued to 19.6 inch-pounds +/– 20%. _________________________ Caution ___________________________ The power bus bars must be torqued properly or the system may not operate. ____________________________________________________________ C. Close the bottom door and tighten the quarter-turn fasteners. Figure 3-19: Reattaching 3V and 5V Leads +3V Thin Red Cable 3V RTN Thin Black Cable 5V RTN Thick Black Cable +5V Thick Red Cable MA01108 3–23 Upgrading the Rackmount Hardware Step 9: Reinstall system bus modules. A. Reinstall CPUs, memories, and plastic fillers. Figure 3-20: System Bus Module and Filler Installation CPU3 MEM3 MEM2 MEM1 MEM0 CPU1 4th CPU CPU0 CPU2 1st CPU 2nd CPU 3d CPU MA00898A _________________________Caution____________________________ Empty slots adjacent to populated slots require a plastic filler to be inserted. ____________________________________________________________ B. Replace the cover and tighten the 2 captive screws. 3–24 Upgrading the Rackmount Hardware Step 10: Reinstall PCI/EISA modules. The AlphaServer 2100A system backplane has 3 EISA slots and 8 PCI slots. The kit provides extra blank plates for PCI/EISA windows, if needed. __________________________ Note_____________________________ Before reinstalling EISA and PCI modules, consult the AlphaServer 2100A Hardware Release Notes (EK-2100A-CL) shipped with this document. The release notes provide configuration guidelines and restrictions to assure optimal operation of options in PCI slots. ____________________________________________________________ Step 11: Reattach the PCI/EISA compartment cabling. Plug the OCP cable, floppy cable, SCSI cable, and remote I/O cable into the PCI/EISA backplane. Step 12: Secure the PCI/EISA compartment door. A. Close the door and tighten the 2 captive screws. B. Slide the system back into the cabinet. Step 13: Reconnect external cables and power supply. A. Reconnect external cables into PCI/EISA modules. B. Plug in the power supply. 3–25 Upgrading the Rackmount Hardware Step 14: Re-label the system. A. Fill in the model number conversion label (36-15946-02): MODEL CHANGED FROM: BA741-A9 TO: BA744-A9 B. Fill in the power ratings label (36-17674-00): Model: Series BA744 SN Repeat BA741 serial number Hz W 50–60 1200 V ~ 100–120/220–240 A 10/5 C. Attach the labels to the system on the rear or left rear of the chassis. Next Steps This completes the hardware upgrade. You now need to update the system firmware, as described in Chapter 4. 3–26 4 Updating System Firmware This chapter provides instructions for updating the SRM and ARC console firmware and the fail-safe loader. You should be at step 4 of the following upgrade process. _________________________ Caution ___________________________ The fail-safe loader (FSL) update switch on the system backplane must be enabled before you can update the fail-safe loader. Refer to the hardware upgrade instructions in Chapter 2 or 3, as appropriate. ____________________________________________________________ Upgrade Process 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. 4–1 Updating System Firmware AlphaServer 2100A Firmware Update Procedure The firmware update procedure is the same for all AlphaServer 2100A models, except for the name of the bootfile: Model Bootfile Name 4/200, 4/233, 4/275 slupdate.exe 5/250, 5/300 glupdate.exe Step 1: Clear SRM and ARC NVRAM. A. Press the Halt button in, then power on the system. B. Clear SRM and ARC NVRAM: P00>>> clear_srm_nvram P00>>> clear_arc_nvram C. Set the operating system type to openvms. P00>>> set os_type openvms D. If you only have a graphics head, set the console environment variable to graphics: P00>>> set console graphics E. Press the Halt button to release it. Step 2: Update the SRM and ARC ROM images. A. Insert the firmware update CD-ROM. B. From the P00>> console prompt, enter the boot command, where dka600 represents the CD-ROM device name. P00>>> boot -fl 0,a0 dka600 . . . 4–2 Updating System Firmware C. After a series of initialization messages, a Bootfile: prompt is displayed. At the Bootfile: prompt, enter the bootfile name for your system. Bootfile: [alpha2100]slupdate.exe !bootfile for 4/nnn systems or Bootfile: [alpha2100]glupdate.exe !bootfile for 5/nnn systems After a series of messages, the loadable firmware update utility banner is displayed: ***** Loadable Firmware Update Utility ***** -------------------------------------------------------------Function Description -------------------------------------------------------------Display Displays the system's configuration table. Exit Done exit LFU (reset). List Lists the device, revision, firmware name, and update revision. Readme Lists important release information. Update Replaces current firmware with loadable data image. Verify Compares loadable and hardware images. ? or Help Scrolls this function table. -------------------------------------------------------------- D. At the UPD> prompt, enter the list command to list the current revision, firmware file name, and update revision. UPD> list E. Update the firmware. UPD> upd Confirm update on: arcflash srmflash [Y/(N)]y WARNING: updates may take several minutes to complete for each device. . . . UPD> 4–3 Updating System Firmware Step 4: Exit the loadable firmware utility. UPD> exit Answer yes to the following prompt: Do you want to do a manual update [y/(n)] y Step 5: Update the fail-safe loader ROM image. A. At the P00>>> prompt, enter the following: P00>>> update_fsl (update -path fslrom -target fslflash) new: <new_firmware_revision> old: <existing_firmware_revision> B. Enter Y at the “Do you really want to continue [Y/N]?:” prompt. FEPROM UPDATE UTILITY CAUTION: EXECUTING THIS PROGRAM WILL CHANGE YOUR CURRENT ROM! Do you really want to continue [Y/N]? : Y DO NOT ATTEMPT TO INTERRUPT PROGRAM EXECUTION! DOING SO MAY RESULT IN LOSS OF OPERABLE STATE. The program will take at most several minutes. Setting to all 0s… Setting to all 1s… Programming… Verifying… Update successful __________________________ Note _____________________________ If the update hangs at “Setting to all 0s,” you have probably forgotten to enable the FSL update switch. Refer to the instructions in Chapter 2 or 3, as appropriate. ____________________________________________________________ C. Press the On/Off switch to turn the system off. 4–4 Updating System Firmware Step 6: Disable the fail-safe loader update switch. To prevent accidental corruption of the fail-safe loader, it is recommended that you disable the fail-safe loader update switch. A. Make sure the system is turned off. B. Access the system backplane. C. Locate the fail-safe loader (FSL) switches on the system backplane. Refer to Figure 2-3 for pedestal system or Figure 3-14 for rackmount system. D. Make sure the FSL enable switch (top switch) is set to the left (disabled). E. Using a small implement, set the FSL console update switch (bottom switch) to the left (disabled). F. Replace doors and panels and turn on the system. Next Steps This completes the firmware update. You now need to update your EISA configuration, and your StorageWorks RAID controller firmware (if applicable), as described in Chapter 5. 4–5 5 Updating Configuration Data This chapter explains how to update your EISA configuration data, using the EISA Configuration Utility. If your system is configured with a StorageWorks RAID controller, you should also update your RAID controller firmware if your existing controller firmware is earlier than V2.16 for EISA controllers and V2.36 for PCI controllers. You should be at step 5 of the following upgrade process. __________________________ Note_____________________________ If the system is going to run Digital UNIX, install the operating system as the last step of the upgrade. ____________________________________________________________ Upgrade Process 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. 5–1 Updating Configuration Data Rebuilding EISA Configuration Data Use the EISA Configuration Utility diskette, minimum V1.8, provided with the upgrade kit, to rebuild EISA configuration data. _________________________Caution____________________________ There are 2 variants of the ECU, one for OpenVMS and Digital UNIX and another for Windows NT. Be sure to use the appropriate ECU diskette for your operating system. ____________________________________________________________ Step 1: Start the ECU Insert the ECU diskette in the drive. At the P00>>> console prompt, enter the ecu command. The ARC firmware will load and then the ECU will boot from the diskette. This process takes several minutes, at most. P00>>> ecu loading ARC firmware resetting all I/O busses . . When the load process is complete, an informational screen is displayed, telling you that you need to fix your configuration data. Then the ARC Boot menu is displayed. Boot menu: Boot Windows NT Boot an alternate operating system Run a program Supplementary menu... Use the arrow keys to select, then press Enter. Step 2: Correct your configuration data. Using the cursor control keys: A. From the Boot menu, select Supplementary menu. B. From the Supplementary menu, select: Set up the system. 5–2 Updating Configuration Data C. From the Setup menu, select each of the following choices in order. Set system time <Enter> Set default environment variables <Enter> Set default configuration <Enter> If you are running Digital UNIX or OpenVMS, choose the defaults by pressing <Enter> at all the prompts. If you are running Windows NT, select the options appropriate for your configuration. For example, set the system time. D. After you set the default configuration, select Run EISA configuration utility from floppy on the Setup menu. Step 3: Step through the ECU dialog boxes. The ECU displays a few dialog boxes. When these begin to appear do the following: A. At the Main Menu dialog box, press <Enter>. B. If an ID mismatch dialog box is displayed, press <Enter> and wait about 30 seconds. C. At the Main Menu dialog box, select STEP5: Save and Exit, and press <Enter>. D. Press <Enter> to save the configuration. E. Press <Enter> again to reboot the ARC console. The ARC firmware will reboot and display the Boot menu. F. If your system is configured with a StorageWorks RAID controller, go to the next section of this chapter. If you do not have a StorageWorks RAID controller, go to Chapter 6. __________________________ Note_____________________________ For information on configuring ISA devices, refer to the system Owner’s Guide. ____________________________________________________________ 5–3 Updating Configuration Data Updating the StorageWorks RAID Controller Firmware If your system is configured with a StorageWorks RAID controller with firmware earlier than V2.16 for EISA controllers and V2.36 for PCI controllers, it is strongly recommended that you update the controller firmware. Use the standalone configuration utility V3.11 supplied on the Firmware Update CD-ROM. Although the utility can be executed from the CD-ROM, the RAID configurations cannot be saved to CD-ROM. It is recommended that you create a utility floppy, as described in Step 1, below. For complete instructions on using the RAID standalone configuration utility, refer to the StorageWorks RAID Array 200 Subsystems Family Controller Installation and Standalone Configuration Utility User’s Guide. _________________________Caution____________________________ Using a version of the standalone configuration utility earlier than V3.11 will render your RAID controller inoperable. Before updating the RAID firmware, do a backup of the existing configuration for each RAID controller. Also record the setups currently in ECU. ____________________________________________________________ Step 1: Create a standalone configuration utility floppy. __________________________ Note _____________________________ Systems running Digital UNIX or OpenVMS will need to create a utility floppy (steps A, B, and C) on a PC equipped with a CD-ROM drive. ____________________________________________________________ A. Insert the Firmware Update CD-ROM into the CD-ROM drive. B. Insert a diskette into the diskette drive. C. At the DOS prompt, copy the RAID Standalone Configuration Utility for AXP Systems from the CD-ROM onto the diskette drive. c:> copy e:\utility\swxcrmgr\*.* a: 5–4 Updating Configuration Data Step 2: Run the utility to set controller parameters. A. On the AlphaServer system, load the ARC firmware. On systems configured for Windows NT, access the Boot menu. On systems configured for Digital UNIX or OpenVMS, enter the arc command at the console prompt. B. From the Boot menu, select Run a program. C. If you are running the utility from the floppy you created, enter the following at the Program to run: prompt: a:swxcrmgr Or, if you are running the utility from the CD-ROM, enter: cd:\utility\swxcrmgr\swxcrmgr.exe Note that if you run the utility from the CD-ROM, you cannot save the configuration unless you insert a FAT-formatted floppy in the floppy drive. __________________________ Note_____________________________ If you are installing a new controller or if the drives on the controller are marked as failed, enter a:swxcrmgr -o from the floppy or cd:\utility\swxcrmgr\swxcrmgr.exe -o from the CD-ROM. ____________________________________________________________ D. From the Main menu, select Controller Setup. The Edit/View Parameters menu is displayed. Use the arrow keys to step through the menu items. Set the Hardware Parameters and Data Parameters as shown in the table below. Set the SCSI Xfr Parameters and Startup Parameters using the values you previously recorded for these parameters. Hardware Parameters Battery-Backup Disabled (enabled if you have battery backup) StorageWorks Fault Management Enabled Data Parameters Default rebuild rate 50 Stripe size (K bytes) 8 Controller read ahead Disabled 5–5 Updating Configuration Data E. After you have set the controller parameters, press the Esc key. At the Save altered controller configuration? prompt, select Yes to save the parameters you have set. Note that if you ran the utility from the CD-ROM, you cannot save the parameters. F. Exit from the utility. You will be returned to the ARC firmware Boot menu. You are ready to update the RAID controller firmware, as described next. Step 3: Update the RAID controller firmware. B. From the Boot menu, select Run a Program. If you are running the utility from the floppy, enter the following at the Program to Run: prompt: a:swxcrfw filename.xxx Or, if you are running the utility from the CD-ROM, copy the firmware.xxx file to a FAT-formatted floppy. For example: c: copy CD:\utility\swxcrmgr\swxcrfwx.xxx a: Keep the floppy disk in the drive, then enter: cd:\utility\swxcrmgr\swxcrfw filename.xxx Filename.xxx is the firmware filename, and xxx is the firmware version you want to load. For multiple controllers, update EISA firmware files first, followed by PCI files. Review the following examples. Filename for Single EISA Controller swxcrfw swxcrfwa.216 Filename for Single PCI Controller swxcrfw swxcrfwp.236 Filenames for Multiple Controllers swxcrfw swxcrfwa.216 swxcrfwa.216 swxcrfwp.236 C. The system displays a series of messages. The final message asks you to cycle the system power. Press the Reset button. Access the Windows NT Boot menu. 5–6 Updating Configuration Data D. At the Program to Run: prompt, enter a:swxcrmgr from the floppy (or cd:\utility\swxcrmgr from the CD-ROM) to start the standalone configuration utility, and view the firmware version displayed on the Main menu to verify the update. • For a PCI controller, exit the utility and remove the standalone utility diskette from the drive. This completes the firmware update for PCI. • For an EISA controller that was V1.99 or earlier before the update, select the appropriate new .CFG file for your controller and copy it to the ECU diskette. The table that follows identifies the .CFG files. • Run the ECU again to load the new CFG file. .CFG Files !MLX0077.CFG 1-channel controller running Windows NT !MLX0075.CFG 3-channel controller running Windows NT AMLX0077.CFG 1-channel controller running Digital UNIX or OpenVMS AMLX0075.CFG 3-channel controller running Digital UNIX or OpenVMS __________________________ Note_____________________________ If you do not have a PC available to copy the .CFG file to your ECU diskette, do the following: 1. Run the ECU and delete the controller board. 2. Add the new controller board. 3. Remove the ECU diskette and insert the standalone utility diskette. 4. At the Add Configuration (CFG) file menu, select the appropriate choice and press Enter. 5. At the Destination Diskette prompt, remove the standalone utility diskette and insert the ECU diskette, making sure it is write-enabled, then press Enter. 6. At the confirmation prompt, press Enter, and at the highlighted slot, press Enter again. The board will now appear on the display. 7. When you have finished adding boards, press F10 to exit. ____________________________________________________________ Next Steps Go to Chapter 6 to complete the upgrade. 5–7 6 Completing the Upgrade This chapter describes how to complete the system upgrade. You should be at step 6 or step 7 of the upgrade process, depending on your operating system. Upgrade Process 1. Update the OpenVMS or Windows NT operating system. Skip this step for Digital UNIX systems. 2. Record any custom configuration information stored in NVRAM. 3. Upgrade the system hardware. 4. Update the system firmware and fail-safe loader. 5. Rebuild the EISA and PCI configuration, and update the RAID firmware, if necessary. 6. Install Digital UNIX. 7. Restore or set up any custom configuration information. Installing Digital UNIX If the upgraded system will be running Digital UNIX, install the Digital UNIX operating system at this time. The operating system CD-ROM is shipped with the hardware upgrade kit. Consult the operating system installation/upgrade documents for instructions on installing the Digital UNIX operating system. After you install Digital UNIX, go to the next section to complete the upgrade. 6–1 Completing the Upgrade Restoring Custom Configurations Use the custom configuration information you recorded prior to the hardware upgrade to restore any customizations to be stored in NVRAM. Refer to the AlphaServer 2000/2100/2100A Firmware Reference Guide for information on setting specific environment variables. 6–2
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies