EK-OTM78-UG-001
May 1980
60 pages
Original
2.0MB
view
download
Document:
TM78 UsersGuide
Order Number:
EK-OTM78-UG
Revision:
001
Pages:
60
Original Filename:
TM78_UsersGuide.pdf
OCR Text
EK-OTM78-UG-OO 1 Magnetic Tape Formatter User Guide digital equipment corporation • maynard, massachusetts 1st Edition, September 1980 Copyright © 1980 by Digital Equipment Corporation All rights reserved. The material in this manual is for informational purposes and is subject to change without notice. Digital Equipment Corporation assumes no responsibility for any errors which may appear in this manual. Printed in U.S.A. This document was set on DIGITAL's DECset-8000 computerized typesetting system. The following are trademarks of Digital Equipment Corporation, Maynard, Massachusetts: DIGITAL DEC PDP DEeUS UNIBUS D ECsystem-1 0 DECSYSTEM-20 DIBOL EDUSYSTEM VAX VMS MASSBUS OMNIBUS OS/8 RSTS RSX lAS CONTENTS CHAPTER 1 GENERAL INFORMATION 1.1 1.2 1.2.1 1.2.2 1.3 1.3.1 1.3.1.1 1.3.1.2 1.3.1.3 1.3.1.4 1.3.1.5 1.3.1.6 1.3.1.7 1.3.1.8 1.3.1.9 1.3.1.10 1.3.1.11 1.4 1.5 Introduction ..'........................................................ 1-1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-1 Options ........................................................... 1-3 Physical Description ................................................ 1-4 Functional Description ................................................ 1-5 System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-6 Common Address Space (M8957) .................................. 1-6 Data Bus Interface (M8956) ....................................... 1-7 Write Micro/Byte Assembly (M8959) .............................. 1-7 Write Translator (M8958) ......................................... 1-7 System Microcomputer (M8960) ................................... 1-8 Tape Unit Port (M8955) .......................................... 1-8 Read Channel Module (M8950) . . . . .. . . . .. .. . .. . . .. . . . . . .. . . . . . .. .. 1-8 Read Path Controller (M8953) ..................................... 1-9 ECC Controller (M8951) ........................................ 1-10 Check Character Controller (M8952) .............................. 1-10 TM78 Maintenance Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-10 Related Documents .................................................. 1-11 Specifications ....................................................... 1-11 CHAPTER 2 PROGRAMMING INFORMATION 2.1 2.2 2.3 2.3.1 2.4 2.5 2.6 2.7 2.8 Introduction .................................... . . . . . . . . . . . . . . . . . . . . .. 2-1 Non-Data Transfers ................................................... 2-1 Data Transfers ........................................................ 2-2 Extended Sense (EXSNS) Command ................................. 2-6 TM78 Initiated Interrupts ............................................. 2-11 TM78 Hardware Control Registers .................................... 2-11 Dual Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-13 Channel Address Summary ........................................... 2-13 Interrupt Code Failure Code Cross-Reference and Summary .............. 2-15 CHAPTER 3 INSTALLATION 3.1 3.2 3.3 3.4 3.4.1 3.4.2 Site Planning and Considerations ....................................... 3-1 Unpacking ........................................................... 3-1 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-1 Installation Procedures ................................................ 3-3 MASSBUS Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-3 TU Bus Cabling .................................................... 3-4 iii 3.4.3 3.4.4 3.5 TM78-C Optional Dual Port Logic ................................... 3-4 Setting MASSBUS Drive Address .................................... 3-5 Acceptance Testing ................................................... 3-7 APPENDIX A EXTENDED SENSE COMMAND (73) DATA BYTES FIGURES 1-1 1-2 1-3 1-4 1-5 1-6 1-7 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 TM78/TU78 Tape Transport System Configuration ....................... 1-2 TM78-AB Subsysteln Configuration ..................................... 1-3 TM78-BB Subsystem Configuration ..................................... 1-3 TM78 Mounted in Master TU78 ....................................... 1-4 TM78 Front View .................................................... 1-5 TM78 System Configuration ........................................... 1-5 TM78 Simplified Block Diagram ....................................... 1-6 Non-Data Transfer Fields .............................................. 2-1 Sense Information Fields .............................................. 2-4 Data Transfer Fields .................................................. 2-5 Byte Assembly Modes and Associated Skip Counts ....................... 2-7 RHI0/20 EXSNS Data Byte Formatting ................................ 2-8 TM78 Initiated Interrupt Fields ....................................... 2-11 TM78 Hardware Control Register Fields ............................... 2-12 RHII and RH70 Address Summary ................................... 2-14 RHI0, RH20, and RH780 Addresses .................................. 2-15 Releasing TM78 Logic Gate ........................................... 3-1 Removing TM78 Logic Cover .......................................... 3-2 TM78 Module Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-2 MASSBUS Cable Terminator Connections .............................. 3-3 MASSBUS Cable Routing and Hardware ................................ 3-4 Radial TU Bus Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-5 TU Bus Cable Routing and Hardware ................................... 3-6 MASSBUS Port NB Drive Address Selector Switch ..................... 3-6 TABLES 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11 2-12 Non-Data Transfer Function Codes ..................................... 2-3 Non~Data Transfer Interrupt Codes ..................................... 2-4 Sense Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-5 Data Transfer Function Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-8 Data Transfer Interrupt Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-9 TM78 Initiated Interrupt Codes ....................................... 2-11 TM78 Hardware Control Register Error Bits ............................ 2-13 Interrupt Code to Failure Code ........................................ 2-16 Non-Data Transfer (NDT) Interrupts to NDT Commands ................ 2-24 Data Transfer (DT) Interrupts to DT Commands ........................ 2-25 TM78 Initiated Interrupts ............................................. 2-26 Host Responses ..................................................... 2-26 tV CHAPTERl GENERAL INFORMATION 1.1 INTRODUCTION The TM78 Magnetic Tape Formatter serves as an interface between a maximum of four TU78 Magnetic Tape Transports and any MASSBUS controller. It provides control, data, status, and error information between the MASSBUS controller and the standard 1.27 cm (0.50 in) TU78 Tape Transport, operating at 318 cm/sec (125 in/sec). The TM78 can read and write magnetic tape for information interchange at 1600 bits/in phase encoded (PE) or 6250 bits/in group-coded recording (GCR). It also has spacing and reverse read capabilities. The TM78 formats data from PDP-II family, DECsystem-IO, DECSYSTEM20 and VAX processors into tape frame characters, and performs the reverse during a data read operation. Aside from magnetic tape formatting, the TM78 offers the following features. 1. 2. 3. 4. 5. 6. 7. 8. 9. Automatic two-track error correction when reading GCR data Resident on-line microdiagnostics Full wraparound maintenance diagnostics Dual MASSBUS port capability Automatic transport velocity monitoring Programmable self-diagnosing facility Full data path parity checking Automatic single-track error correction when reading PE data Automatic error repositioning for retries 1.2 GENERAL DESCRIPTION Figure 1-1 illustrates a TM78/TU78 tape transport system configuration. Up to four TU78 tape transports can interface with one TM78 tape formatter. Each transport is independently cabled using a radial bus configuration. Thus, one or more transports can be removed while the others remain on-line. Each MASSBUS controller can control up to eight TM78 formatters. Thus, a maximum of 32 TU78 tape transports could interface with a single MASSBUS controller. 1-1 MASSBUS ,...----, ...---........ RADIAL BUS NETWORK TRANSPORT 2 TRANSPORT 3 TRANSPORT 1 ~ TRANSPORT 2 TRANSPORT 3 MA-6110 Figure 1-1 TM78/TU78 Tape Transport System Configuration 1-2 TU PO TM78 FORMATTER TU P1 MA-610e Figure 1-2 TM78-AB Subsystem Configuration PORT A TU PO TM78 FORMATTER PORT TU P1 B MA-6109 Figure 1-3 1.2.1 TM78-BB Subsystem Configuration Options The list below briefly describes all available TM78 options. Option No TM78 Configuration TM78-AB Single port TM78 capable of interfacing with single MASSBUS and up to four TU78s (Figure 1-2) TM78-BB Dual port TM78 capable of interfacing with two MASSBUSes and up to four TU78s (Figure 1-3) TM78-C Dual port adapter kit for TM78-AB 1-3 TU78 BASE ASSEMBLY TM78 TAPE FORMATTER MA-6155 Figure 1-4 TM78 Mounted in Master TU78 1.2.2 Physical Description Figure 1-4 shows the TM78 mounted within the master TU78 tape transport cabinet. An H7422-AB power supply provides power for the TM78, and is mounted in the rear of the master cabinet. Major subassemblies of the TM78 are the H7422-AB plus regulators (PN 70-17121) and TM78 tape formatter logic gate. Figure 1-5 shows the front view of the TM78. 1-4 MAINTENANCE PANEL LOGIC BACKPLANE MASSBUS CONNECTORS (4) MA-6156 Figure 1-5 MASSBUS CONTROLLER TM78 Front View TM78 FORMATTER PO P1 TO 1-7 OTHER DRIVES Figure 1-6 MA-6107 TM78 System Configuration 1.3 FUNCTIONAL DESCRIPTION The TM78/TU78 tape transport system (Figure 1-6) interfaces with the central processor unit (CPU) via the MASSBUS controller. However, the MASS BUS controller is almost transparent to the CPU; that is, the CPU operates as though it controls the drive directly. (Throughout this manual, drive refers to a complete tape subsystem, comprising a TM78 tape formatter and a TU78 tape transport.) The TM78 interfaces with the MASSBUS controller via the MASSBUS. The MASSBUS consists of an asynchronous control bus and a synchronous data bus, both with associated control lines. Transactions on the control bus control the drive and determine its status, while transactions on the data bus transfer data to or from the drive. Because the data and control buses operate independently, the MASSBUS controller can monitor drive status during a data transfer operation. 1-5 I'MS960 -MIC;;CO~E'R1 r - - - - , I < 8085 J.lp CONTROL BUS ~ WRITE ,. READ BUS BUS (5 TO 4) Figure 1-7 MA-6106 TM78 Simplified Block Diagram The TM78 can control up to four tape transports through its dual port/radial bus scheme. Each tape unit bus (radial bus) cable set is identical with one tape transport per cable set to the formatter. The bus consists of write data, read data, control and various transport status lines. 1.3.1 System Operation Figure 1-7 is a block diagram of the TM78, showing the major functional groups, control lines, and data paths. The following paragraphs describe these functional groups. While reading them, keep in mind that the word system implies the TM78 microcomputer system, and not some other portions (e.g., VAX, 11/70) or an overall computer system also run under microcode. 1.3.1.1 Common Address Space (M8957) - The common address space (CAS) interfaces the TM78 with the MASSBUS controller. It contains circuitry that decodes the drive select signals on the MASSBUS. Enabled by the proper drive select address code, the CAS module can carryon handshake operations with the MASSBUS controller, reading and writing TM78 registers. Two TM78 registers provide a direct path from the MASSBUS to TM78 hardware. These registers are used for initialization, loading and verification of diagnostic microcode, starting and stopping the microprocessor, and diagnostic register access. The most important parts of the two registers are internal address and internal data. 1-6 The system microcoITlputer decodes command information in CAS registers and generates appropriate control signals to the transport. The module/microcode (that is, the microcode within the module) also determines when to p(~rform a data transfer operation. When this is the case, it generates OCC (occupy) on the MASSBUS to notify the controller that it has occupied the data bus. 1.3.1.2 Data Bus Interface (M8956) - The data bus interface module interfaces the TM78 data paths with the MASSBUS c:ontroller. The data bus interfac,e is enabled for operation when the MASSBUS controller signal OCC is asserted. During a write operation, the MASSBUS controller places a data word on the data bus. When the data bus interface is ready to accept this data word, it asserts S CLK (sync clock) to the controller, which then replies with W CLK (write clock). After receiving W CLK, S CLK is negated and the data bus interface strobes in the I8-bit word on the data bus. After generating W CLK, the MASSBUS controller places the next data word on the data bus. When the data bus interface module completes transferring the previous data word to the byte assembly logic (M8959), it issw~s another S CLK, receives another W CLK, and strobes in the next data word for transfer. The process continues until all data has been transferred (providing there are no data errors or other failures). During a read operation, the data bus interface module receives an I8-bit word from the byte assembly logic. It is placed on the data bus, along with a parity bit (D PAR), and the data bus interface generates an S CLK pulse. When the MASSBUS controller receives S CLK, it strobes in the data on the data bus. The data bus interface module continues to receive I8-bit data words, and notifies the controller that a data word is available by generating S CLK. As in a write operation, the method of word/character assembly is under complete control of the system microcode. 1.3.1.3 Write Micro/Byte Assembly (M8959) - The write micro/byte assembly module is a ROM microcontroller dispatched on various tasks and monitored by the system microcomputer (M8960). In addition to allowing diagnostic data injection to the write logic during diagnostic testing, the write micro portion of the module functions in both write and read modes. Write Mode 1. 2. 3. 4. 5. 6. 7. 8. Receives data from MASSBUS data module Disassembles data for translator in one of seven formats Checks data parity from MASSBUS Generates data parity to translator CRC character calculation ECC character calculation (GCR) ACRC character calculation (GCR) Formats rel)idual and CRC data groups (GCR) Read Mode 1. 2. 3. 4. 5. Receives data from read logic Assembles data for MASSBUS in one of seven formats Generates data parity to MASSBUS Checks data parity from read logic Facilitates data byte skip count 1.3.1.4 Write Translator (M8958) - The write translator is a ROM microcontroller initialized by the system microcomput~~r (M8960). Once initialized, it is controlled by the write micro portion of the M8959 module. The write translator contains a microprogram ROM, subgroup buffers, translation 1-7 ROMs, and control logic required to translate 4-bit data bytes into the 5-bit characters required in GCR formatting. In general, during a GCR write operation, this module performs the following functions. 1. 2. 3. 4. 5. 6. 7. Generates preamble and postamble Performs 4 to 5 translation Generates resync burst Generates end mark Controls flux reversal rate Provides track enable/disable functions Writes all ones The module also performs the following functions during PE write operations. 1. 2. 3. Generates preamble and postamble Controls flux reversal rate Provides track enable/disable functions 1.3.1.5 System Microcomputer (M8960) - The system microcomputer module uses an 8085 microprocessor chip to act as the heart of the TM78 control bus (microbus). PROM space contains the operating system and diagnostic monitors. Specific diagnostic routines are loaded from the host computer system into 4K of additional RAM spaces before they are run. The microcomputer directs TM78 operation over the TM78 microbus. it interfaces with the host CPU through the data bus interface and the CAS (common address space). The microcomputer's addressable memory space extends to the CAS. In this context, they form a tightly coupled asymmetrical multiprocessor system. 1.3.1.6 Tape Unit Port (M8955) - The tape unit port module interfaces the TM78 formatter with the tape transport. Two tape unit port modules may be used in each TM78 formatter, each module interfacing with two TU78 tape transports. During a TM78 write operation, the tape unit port module accepts either GCR or PE formatted data from the M8958, and transmits it to the tape transport to be written onto tape. Under complete microprogram control, bits in a TU command word inform the tape transport as to what format the proceeding data is in. During TM78 read or write operations, the tape unit port module accepts either GCR or PE data. This time the data is to the TM78 from the tape transport. Again, the TU command word defines the data format. This module also performs the following functions when the TM78 is running in diagnostic mode. 1. 2. 3. 4. 5. 6. 7. Loops translator to microcomputer Loops translator to read path Loops microcomputer to read path Loops transport command register to transport status register Loops microcomputer to AMTIE (amplitude track in error) lines Loops AMTIE lines to microcomputer Loops read data to microcomputer 1.3.1.7 Read Channel Module (M8950) - Nine read channel modules are used in the TM78 formatter, one for each tape track. Read channels are ROM microcontrollers, dispatched and monitored by the read path microcontroller (M8953). Read information feeds through the read channels, read data path, byte assembly, and data bus interface to the MASSBUS, and on to the CPU. During the read-after-write portion of the write cycle, information goes only as far as read data path logic, where ECC and CRC/ ACRC checking are performed. 1-8 Basically, functions of the M8950 module during PE read/write operation are as follows. 1. 2. 3. 4. 5. Searches for preamble Passes data to ECC Deskews data Read revers Ie correction Verifies PE flux reversal The main function of 1the module during GCR read/write operation is to translate the 5-bit GCR formatted data back into the original 4-bit format. Additional functions are as follows. 1. 2. 3. 4. 5. 6. Searches for Mark 1 Passes data to ECC Deskews data Read revers~~ correction AMTIE signal detection TIE pointer generation 1.3.1.8 Read Path Controller (M8953) - The read path controller is a ROM microcontroller, dispatched and monitored by the system microcomputer. The read path dispatches and controls the nine read channel modules (M8950), and provides control information for the microcontrol portion of the ECC module. This module also serves as a central area of status reporting for the entire read electronics (read channels, ECC, and check character microcontroller parts). The basic module functions for the respective formatter operations are listed below. Write PE 1. 2. 3. 4. Tests IRG (iinter-record gap) Tests ID Burst Tests Tape ~v1ark Read-after-write WriteGCR 1. 2. 3. 4. 5. 6. Tests IRG Tests ID Tests Tape ~v1ark Tests ARA ][D Tests ARA Burst Read-after-write ReadGCR 1. 2. 3. 4. 5. Reads GCR forward Reads GCR reverse Samples density at BOT Detects ARA ID Detects Tape Mark Read PE 1. 2. 3. 4. Reads PE forward Reads PE reverse Samples density at BOT Detects Tap1e Mark 1-9 Diagnostic Mode 1. 2. 3. Self tests diagnostic Status register test Load/read FIFO data 1.3.1.9 ECC Controller (M8951) - The BCC (error correcting code) controller module is a ROM microcontroller initialized by the system microcomputer, and thereafter controlled by the read path (M8953). This microcontroller implements the error-correction algorithms in both GCR and PE data formats, and in both read and write modes. Read PE 1. Single track error correction Write/Read GCR 1. 2. Single track error correction always Double track error correction with pointers 1.3.1.10 Check Character Controller (M8952) - The check character (CRC and ACRC) controller module is a ROM microcontroller initialized by the system microcomputer, and thereafter controlled by the ECC controller (M89 51). This microcontroller performs check character algorithms in both read and write modes, PE and GCR data formats. WriteGCR 1. Verifies CRC and ACRC check characters Read GCR 1. 2. Verifies CRC and ACRC check characters Passes data to byte assembly logic (M8959) Write PE 1. Generates CRC verification character Read PE 1. Passes data to byte assembly logic (M8959) 1.3.1.11 TM78 Maintenance Panel - A maintenance panel, consisting of pushbuttons and LED indicators, is provided to enhance subsystem troubleshooting. The maintenance panel is tied to the resident microcomputer and permits inspection of the formatter and transport without disabling the host CPU. The panel keyboard/display is controlled exclusively by the TM78 microcode. The display remains blank until the ENA key is pressed, and recognized by the microcode; at that time, the LEDs display HELLO. The keyboard is enabled and all the keys may be used. Subsystem failures and keypad operator errors generate a failure code (number) indicatd by the LEDs. The failure codes and associated subcode listings define the particular error or problem. This aids maintenance personnel, permitting them to work with one transport off-line, while the rest of the system remains on-line. Refer to Paragraph 5.5 of the TM78 Technical Manual for detailed information. 1-10 1.4 RELATED DOCUMENTS The following list describes documents related to the TM78 formatter. Title Doc No Contents PDP-II Peripherals Handbook Register descriptions for RH MASSBUS controllers RH 10 MASSBUS Controller Maintenance Manual EK-RH IO-MM-002 Theory and maintenance of RHI0 MASSBUS controller RH20 MASSBUS Controller Unit Description EK-RH20-UD-00I Description of RH20 MASSBUS controller RH780 MASSBUS Adapter Technical Description EK-RH780-TD-00I Programming and theory of RH780 MASSBUS adapter TM78 Field Maintenance Print Set MPOI061 Engineering drawings and parts lists for TM78 mechanics and logic H7422 Field Maintenance Print Set Part of MPOI061 Engineering drawings and parts lists for TM78 power supply chassis H7441 Field Maintenance Print Set Part of MPOI061 Engineering drawings and parts lists for + 5 volt regulator H7476 Field Maintenance Print Set Part of MPOI061 Engineering drawings and parts lists for ± 15 volt regulator H7490 Field Maintenance Print Set Part of MPOI061" Engineering drawings and parts lists for - 5 volt regulator 1.5 SPECIFICATI()~NS Data Transfer Speed 780,000 char / sec maximum Error Detection PE Single track error correction GCR Maximum record leng.:h Single track error correction always; Double track error correction with pointers; CRC / ACRC check character verification 65,536 characters (PE and GCR) 1-11 Minimum record length Environment Operating Nonoperating Altitude Operating Nonoperating Shock Operating Nonoperating Vibration Operating Nonoperating Power Requirements DC AC 1 character (PE and GCR) 10° C (50 OF) to 40° C (104 OF) 10 to 90 percent relative humidity Wet bulb: 28° C (82 OF) maximum Dew point: 2° C (36 OF) minimum - 40 ° C ( - 40 ° F) to 66 ° C (151 ° F) oto 95 percent relative humidity 2.4 km (8000 ft) maximum 9.1 km (30,000 ft) maximum Withstands half-sine shock pulse of 10 G, peak with 10 ± 3 ms duration Withstands half-sine shock pulse of 40 G, peak with 30 ± 10 ms duration Withstands vibration of 0.051 mm (0.002 in) double amplitude (maximum) in the frequency range of 5 to 50 Hz Withstands vibration of 0.25 G, peak, in the frequency range of 50 to 500 Hz None Input voltage range Single phase Frequency Power consumption TM78 Logic Assembly Mechanical Specifications Height 40 cnl (15.7 5 in) Width 48.25 cm (19 in) Depth 27.3 em (10.75 in) Weight 5.9 Kg (25Ibs) 1-12 184-256 Vac 47-63 Hz 525 VA typical 700 VA maximum H7422 Power Supply Mechanical Specifications Height 13.3 em (5.25 in) Width 48.25 em (19 in) Depth 26.7 em (10.5 in) Weight 20.4 Kg (45 lbs) Data Reliability Established by error rate of transport as follows: Recoverable Nonrecoverable 1-13 GCR PE Read 1 in 109 1 in 109 Write 1 in 107 1 in 107 Read 1 in 10 10 1 in 10 10 CHAPTER 2 PROGRAMMING INFORMATION 2.1 INTRODUCTION This chapter contains the programming information required by a user for a system containing the TM78 formatter. The information applies only to the TM78; programming information for other system units can be found in the applicable documentation. The TM78 common address space (CAS)is used by the host CPU and the internal microcomputer. The CAS is located within the TM78, but is viewed as an extension to the memory address space of both the host CPU (except for DECsystem-l0 and DECSYSTEM-20) and TM78 microcomputer. Within this context, they form a tightly coupled, asymmetrical, multiprocessor system. This chapter defines the manner in which the different processes cooperate. This chapter also contains information about the use of the TM78 hardware control registers. These registers are used during subsystem initialization and diagnostic testing. The TM78 GCR/PE tape formatter is a MASSBUS device, and is subject to the same configuration rules as other MASS BUS devices (i.e., up to eight TM78s per bus). Each TM78 may connect with as many as four TU78 tape transports. The MASS BUS controller dictates how the TM78 is accessed by the program. Details of programming the MASS BUS controller and data channel (if any) are not provided. 2.2 NON-DATA TRANSFERS The non-data transfer interface consists of one command location per tape transport, a status location shared by all transports, and the ATTN bit (Figure 2-1). RH11/ RH70 RH20 15 16 4 0 36 13 FAI LURE CODE 40 14 42 14 13 12 11 10 • 9 BITS 8 7 .. 0 I ATTN ADR 6 5 4 3 2 0 ATTENTION BIT 0 0 INTERRUPT CODE COMMAND COUNT 0 0 0 FUNCTION CODE 0 GO 15 COMMAND COUNT 1 0 0 FUNCTION CODE 1 GO 44 16 COMMAND COUNT 2 0 0 FUNCTION CODE 2 GO 46 17 COMMAND COUNT 3 0 0 FUNCTION CODE 3 GO STATUS COMMAND NOTES: 1. RH11/RH70 COLUMN REFERS TO BASE ADDRESS (172400) PLUS NUMBER (OCTAL) INDICATED. 2. RH20 COLUMN REFERS TO REGISTER SELECT BITS. Figure 2-1 Non-Data Transfer Fields 2-1 MA-6102 The host CPU may have up to four comnlands active at any time. The ATTN bit corresponds to the TM78 drive address and is set when a command is completed. Then, the host reads the ATTN ADR to determine the tape unit that has finished, and the Interrupt Code corresponding to the interrupt-level action to take. If the Interrupt Code indicates a hardware fault condition, then the Failure Code contains additional information for the system error log. To allow for further interrupts, the host CPU must write a logical one into the ATTN Bit after reading the Status location. Command completion interrupts do not necessarily occur in the same order as command initiations. The Command Count specifies the number of times the command is to be repeated (octal 377 maximum). If the operation terminates prematurely, then the Command Count contains the number of operations not completed successfully. A COlnmand Count of 0 or 1 may be used to specify a single operation. The TM78 automatically performs all error recovery for non-data transfers. Unrecoverable errors and hardware faults are reported. The GO bits inform the TM78 that a new command has been loaded. They are not status bits because the readability is undefined. Non-data transfer function codes and interrupt codes are listed in Tables 2-1 and 2-2, respectively. Table 2-8 cross-references interrupt codes to failure codes. The Sense command may be used to obtain information about a specific tape transport. This information is available to the user during the time the ATTN bit is set for this command (Figure 2-2). Sense information is provided primarily for system initialization and error logging. It is not necessary for proper operation during non-error situations. Table 2-3 lists all the Sense information mnemonics. 2.3 DATA TRANSFERS The data transfer interface is shared by all four tape transports; therefore, only one transfer may be active at a time. The data transfer command is specified by the Function Code, Record Count, Format, Byte Count, Command Address, and Skip Count. Status information for read/write operations is presented through the Interrupt Code, Byte Count, Record Count, and Failure Code fields (Figure 2-3). The Function Code and GO bits are loaded after the three locations that define a command. It is not usually necessary to reload registers 2 and 5 in the RH20 (addresses 14 and 6 in the RH 11 /RH70) in order to repeat an operation (refer to Table 2-5). These locations must not be altered by the host CPU until the operation has finished. Command completion is signaled by a CMD (command done) interrupt in the RH20, and an RDY interrupt in the RH 11 /RH70. (The attention interrupt is not used for data transfers). The host CPU reads the Interrupt Code to determine which interrupt-level action to take. All Interrupt Codes, except DONE, are accompanied by the DEE bit (drive exception error) in the RH20 and the TRE bit (transfer error) in the RHll/RH70. The CMD ADR specifies the tape unit to be used. This may not be the address of a tape unit for which a non-data transfer command is active. 2-2 Table 2-1 Non-Data Transfer Function Codes Function Code (Go bit included) Name 03 NOOP Generate a unique NO OP interrupt code 05 Unload Unloads tape and interrupts immediately 07 Rewind II Sense 13 Data Security Erase 2 Erase remainder of tape and rewind 15 WTMPE 3 Writes phase encoded tape mark 17 WTMGCR 3 Writes GCR tape mark 21 SP FWD REC Spaces forward record, stops if tape mark 23 SP REV REC Spaces reverse record, stops if tape mark or BOT 25 SP FWD FILE Spaces forward file (to tape mark) 27 SP REV FILE Spaces reverse file (to tape mark) 31 SP FWD EITHER Spaces forward either record or file 33 SP REV EITHER Spaces reverse either record or file 35 ERGPE 3 Erases three inches of tape, sets PE 37 ERGGCR 3 Erases three inches of tape, sets GCR 41 Close File PE 3 Writes two tape marks, spaces reverse one, sets PE 43 Close File GCR 3 Writes two tape marks, spaces reverse one, sets GCR 45 SPACE LEOT 47 SPACE FWD FILE/LEOT Note 4 Description Rewinds tape and interrupts when done Puts status information into CAS Spaces forward until two tape marks, spaces reverse one 5 Spaces forward to tape mark, stops if two successive tape marks (logical end of tape) NOTES I. Sense registers are valid as long as the ATTN bit is set. 2. Erases at least 3.05 m (10 ft) beyond the EOT marker. 3. Recording format is ignored except when tape is at load point (BOT). It is specified by bit 1. 4. Sometimes intemlpts when rewind starts; always interrupts after tape motion has stopped. 5. Do not use after any reverse operation; the TM78 may skip over an LEOT located where direction was reve:rsed. 2-3 Table 2-2 Non-Data Transfer Interrupt Codes Interrupt Code Name Description 01 DONE Operation completed as expected 02 TM Unexpected tape mark 03 BOT Unexpected beginning of tape 04 EaT Tape positioned beyond end of tape marker (write) 05 LEOT Unexpected logical EaT (two tape marks) 06 NOOP NO OP completed 07 RWDING Rewind in progress; DONE interrupt follows when at BOT 10 FPT Write attempted on file protected tape 11 NOT RDY TU on-line; tape rewinding or loading, or DSE being performed from other port 12 NOT AVAIL TU not switched to this port, but is on-line 13 Off Line TU not switched on-line 14 NON EX TU does not exist or power is off 15 Not Capable 1. Incorrect ID Burst read 2. No record or tape mark detected 27 Bad Tape Tape position lost 30 TM FAULT A TM78 hardware has failed, or the CAS was loaded with incorrect command information (see failure code for details) 31 TUFAULT A Tape unit hardware has failed (see failure code for details) RH11/ RH70 RH20 15 14 13 26 6 1 1 0 20 7 ROY PRES ONL 30 10 BCD SN 12 11 10 9 0 DUAL MB 1 0 REW PE BOT EOT 3 BCD I SN 8 6 5 4 3 2 o DRIVE TYPE FPT AVAILl SHR lMAINTI DSE 0 0 2 BCD BCD SN SN 1 0 0 0 NOTES: 1. RH11/RH70 COLUMN REFERS TO BASE ADDRESS (172 400) PLUS NUMBER (OCTAL) INDICATED. 2. RH20 COLUMN REFERS TO REGISTER SELECT BITS. MA-6173 Figure 2-2 Sense Information Fields 2-4 Table 2-3 .Sense Information Name Definition DUALMB When set, TM78 has dual MASSBUS port option DRIVE TYPE Octal 101 for TU78 tape drives RDY Tape unit has tape mounted, is on-line, and is not rewinding or perfonning DSE PRES Tape unit has power applied ONL Tape unit is on-line and tape is mounted REW Tape unit is rewinding PE When set, tape unit is set for PE recording format; when clear, tape unit is set for GCR recording format BOT Tape is positioned at load point EOT Tape is positioned beyond end-of-tape marker FPT Tape unit is write protected AVAIL Tape unit is available to this MASSBUS SHR Tape unit is available to both MASSBUS ports (shared) MAINT Tape unit is in maintenance mode, and may not be used DSE Tape unit is performing erase portion of DSE command BCDSN Binary-coded-decimal serial number of the tape unit RH11/ RH70 RH20 15 14 13 12 11 10 o 0 0 +----+ 0 DVAI 0 14 2 SERI 6 5 12 FORMAT BITS 8 7 9 .. • SKIP COUNT 1 6 5 o I 4 3 2 FUNCTION CODE RECORD COUNT I o GO ICMD ADR BYTE COUNT FAILURE CODE I 1DP~ 0 0 o I INTERRUPT CODE NOTES: 1. RH11/RH70 COLUMN REFERS TO BASE ADDRESS (172 400) PLUS NUMBER (OCTAL) INDICATED. 2. RH20 COLUMN REFERS TO REGISTER SELECT BITS. Figure 2-3 Data Transfer Fields 2-5 MA-6103 The Record Count specifies the number of records to read or write, and may be any value in the range of 0 to 778. When it is not zero, it is decremented after every record correctly transferred. When it is zero, the TM78 transfers records until stopped by the MASSBUS controller. The RH20 has its own block counter and may be operated with the Record Count set to zero. For the RH 11 /RH70, a block of memory may be divided into multiple records by using the Record Count. Record Count is zero upon a normal termination, and after an error occurs indicates the number of records remaining to be transferred. It is not decremented during unsuccessful error retry operations, so that it does not have to be reloaded after an error, unless the TM78 issues a Read Opposite interrupt code. In this case, the Record Count should be set to zero. When writing, records are always started with byte A (Figure 2-4). Any unwritten bytes in the last word of a buffer are not written in the next record. The length of the record (or records) to be read or written is determined by the Byte Count. The entire record is always sent to the MASSBUS controller, even if it is longer than Byte Count indicates. If the record length differs from the Byte Count, the actual length is returned in Byte Count, unless the interrupt code is Read Opposite (refer to Table 2-8). In addition, the MASSBUS controller can detect record length errors when the TM78 transfers an unexpected number of bytes to the MASSBUS controller (or channel). A Byte Count of zero implies 2 16 bytes. If the TM78 detects an error that requires a retry, it positions the tape for the retry operation unless SER (suppress error repositioning) is set. If SER is not set, error recovery algorithms of the TM78 inform the host CPU of the next operation to perform via the interrupt code. A record is declared unreadable if repeated error recovery attempts fail. If a record cannot be written, the TM78 responds with BAD TAPE (Interrupt Code 27). The Format field (Figure 2-4) defines the manner in which tape bytes are assembled to/from the host CPU words. Skip Count is used during tape read operations to zero-fill the specified number of byte positions before reading the first data byte. These zero-filled bytes are transferred from the TM78 even if no data bytes are read (because of an error). 2.3.1 Extended Sense (EXSNS) Command The EXSNS command is used to read error log data from the TM78. This log data should be read and placed into the host system error log file whenever interrupt code host response J is executed (refer to Paragraph 2.8). This command functions in a manner similar to the READ FWD command, except that SER, Format, Skip Count, and Byte Count fields are ignored. The EXSNS command always sends 6010 (748) bytes of sense data over the MASSBUS data bus in the 11 Normal format. This produces an ordered string of bytes in an RHll, RH70 or RHII/780. In an RHI0/20, the CPU word is formatted as shown in Figure 2-5. The TM78 maintains separate log data for each of the four possible tape transports. The CMD ADR field selects which set of log data is read. Log data is updated whenever an interrupt code is presented to the host, and one of the following conditions is true. 1. The interrupt code is TM, BOT, EaT, FPT, NOT RDY, NOT AVAIL, Off Line, NON EX, Not Capable, Retry, READ OPP, Unreadable, Error, EaT ERROR, Bad Tape, TM FAULT A, orTU FAULT A. 2. The failure code is not zero. Both data transfer and non-data transfer errors cause log data to be updated. Log data is never cleared. Refer to Appendix A for a description of the extended sense data bytes. Data transfer function codes are listed in Table 2-4, and data transfer interrupt codes are listed in Table 2-5. 2-6 BYTE ASSEMBLY MODES FORMAT SKIP COUNTS ASSEMBLY ~ 8 7 15 000 11 NORMAL 001 15 NORMAL I I o I 10 COMPATIBLE 7 8 o 011 I 10 CORE DUMP 78 o WORD 1 tv I 100 10 HIGH DENSITY COMPATIBLE -.J I o WORD 2 I 7 8 A C B 3 4 DIE 2324 I 19 20 I G 31 32 I C 11 12 ElF 31 32 I 15 16 I D H 35 I 35 ~~~~S I 101 910 0 I A I 2728 I IMAGE PDP.ll/PDP. 15 1 WORDS 110 10 HIGH DENSITY DUMP I 0 15 SAME AS 10 HIGH DENSITY COMPATIBLE, EXCEPT IF A RECORD STARTS OR TERMINATES WITH BYTE E, THE WORD CONTAINING ONLY HALF OF BYTE E WILL NOT BE TRANSFERRED. Figure 2-4 B A B A D A E A I A I 1 B A B A B C B D B H B H 2 C B C C C G C G 3 D A D B D F D F E A E E E* E** 5 F* D** F* D** 6 G* C** G* C** 7 H* B** H* B** 10 1* A** 1* A** I B I WORD 1 IS NOT SENT WORD 2 IS NOT SENT 35 8 7 0 A 35 I 17 18 0 4 A WORD IS TRANSFERRED DURING A READ OPERATION ONLY IF IT CONTAINS DATA OR SKIPPED BYTES. WORDS THAT CONTAIN ALL SKIPPED BYTES ARE NOT SENT. o HIGH HIGH HIGH HIGH DENS DENS DENS DENS 15 15 11 11 10 10 10 10 ;KIP NORM NORM NORM NORM COMP COMP DUMP DUMP COMP COMP DUMP DUMP ;OUNT FWD REV FWD REV FWD REV FWD REV FWD REV FWD REV 1 I I 27 28 I 35 0 1 D 2324 I B I B 31 32 I C 15 16 I A 23 24 I B I 0 I A 1516 I A A 8 7 15 010 0 I B 0 A I NOTES: THIS CHART INDICATES THE LOCATION OF THE FIRST BYTE READ VERSUS THE SKIP COUNT. SKIPPED BYTES IN THE FIRST WORD CONTAIN ZEROS. UNDEFINED SKIP COUNTS RESULT IN A TM FAULT A INTERRUPT. Byte Assembly Modes and Associated Skip Counts ! 012 10101 17 18 19 20 910 BYTE A BYTE B II 10 a 35 27 28 BYTE D BYTEC ~ MA6100 Figure 2-5 RH 10/20 EXSNS Data Byte Formatting Table 2-4 Data Transfer Function Codes Function Code (Go bit included) Name Description 51 WRTCKFWD Write Check Forward. Tape subsystem reads one record in a forward direction. Data is checked in RH controller. 57 WRT CK REV Write Check Reverse. Tape subsystem reads one record in a reverse direction. Data is checked in RH controller. 61 WRITE PE* Write phase encoded records 63 WRITE GCR* Write group-coded records 71 READ FWD Read records forward 73 EXSNS Read extended sense error log 77 READ REV Read records reverse *The recording density format is ignored unless the tape is positioned at load point. At load point, the write command specifies the recording format of the entire tape. 2-8 Table 2-5 tv I \0 Data Transfer Interrupt Codes Int Code Name DeImition Tape Position Byte Count Record Count 01 DONE READ OR WRITE completed successfully As expected No change 0 02 TM Unexpected tape mark encountered during read operation, otherwise read correctly After tape mark No change Number of records left 03 BOT Unexpected BOT encountered during read reverse operation, no other errors At BOT No change Number of records left 04 EOT Write operation successfully completed beyond EOT marker As expected No change Number of records left 10 FPT Write attempted on file-protected tape No change No change No change 11 NOTRDY TU is on-line and switched to this port, but is rewinding or loading N/A No change No change 12 NOT AVAIL TU is on-line, but not switched to this port No change No change No change 13 OFF LINE TU is not on-line No change No change No change 14 NON EX TU does not exist, or power is off No change No change No change 15 NOT CAPABLE 1. Incorrect or no ID Burst detected 1. At BOT No change No change 2. No record or tape mark detected 2. Approx. 25 ft from previous position No change No change Actual record length Number of records left 20 LONG REC Last record read longer than initial Byte Count value, but otherwise read correctly After long record Table 2-5 Data Transfer Interrupt Codes (Cont) Int Code Name Definition Tape Position Byte Count Record Count 21 SHORT REC Last record read shorter than initial Byte Count value, but otherwise read correctly After long record Actual record length Number of records left 22 RETRY Error; initial operation should be repeated Positioned for retry Initial byte count Number of records left 23 READ OPP Read error; initial read should be performed in opposite direction After bad record Number of bytes to be read Number of records left 24 UNREADABLE Read retries have failed to read record After bad record Number of bytes transferred Number of records left 25 ERROR Error has occurred which requires a retry but SER is set (excludes length errors) After bad record Number of bytes transferred Number of records left 26 EOTERROR Write error has occurred beyond EOT marker, and SER is set After bad record Number of bytes transferred Number of records left 27 BAD TAPE Tape position has been lost, or write retries have failed to write record Undefined Number of bytes transferred Number of records left 30 TM FAULT A Hardware has failed, or software bug has been detected. (Failure Code contains more specific information) Unknown Unknown Unknown 31 TUFAULT A Tape unit has failed (Failure Code contains more specific information) Unknown Unknown Unknown tv I 0 NOTE In the above description, the "initial" operation or Byte Count is that of the command before any errors occurred (i.e., the user-specified operation). The "number of records left" is the sum of those records initially specified but not yet accessed and those records accessed but failed because of an unexpected condition. RH11/ RH70 RH20 15 14 16 4 0 • 36 13 13 12 11 10 9 8 • I FAILURE CODE BITS 7 6 ATTN ADR 5 4 3 2 0 o I INTERRUPT CODE NOTES: 1. RH11/RH70 COLUMN REFERS TO BASE ADDRESS (172 400) PLUS NUMBER INDICATED 2. RH20 COLUMN REFERS TO REGISTER SELECT BITS. Figure 2-6 Table 2-6 0 ATTENTION BIT 0 MA-6104 TM78 Initiated Interrupt Fields TM78 Initiated Interrupt Codes Code Name Note Definition 17 ON LINE 3 A tape unit has come on-line with a tape loaded or rewinding 32 TM FAULTB 1,2 The TM78 has detected an internal hardware failure 34 MB FAULT 1,2 MASSBUS error has occurred NOTES 1. ATTN ADR is not meaningful. 2. TM CLR operation must be performed. 3. Sense information is valid during the interrupt. 2.4 TM78 INITIATED INTERRUPTS The TM78 may initiate interrupts to the host CPU under certain conditions that are not the result of commands. Interrupts are sent via the non-data transfer status locations. An interrupt is initiated by the TM78 when a tape drive comes on-line (Figure 2-6). It is sent to the MASS BUS port (or ports) as determined by the port selection switch in the tape drive. The ATTN ADR indicates which drive has come on-line. (Refer to Paragraph 2.6 for more information about this switch.) If TM78 internal diagnostics detect a hardware faul~ during an idle period, a FAULT B interrupt is issued. The Failure Code contains specific information, possibly stored in the system error log, about the nature of the failure. This interrupt is sent to both MASSBUS ports. After a FAULT B interrupt, the TM78 does not respond to commands until a TM CLR (refer to Paragraph 2.5) is issued by the host CPU. Only one FAULT B interrupt can occur during each TM CLR operation. All MB FAULTS are similar, except they are sent only to the port in error. Table 2-6 lists all the interrupt codes initiated by the TM78. 2.5 TM78 HARDWARE CONTROL REGISTERS Two registers are implemented to provide a direct path from the MASSBUS to the TM78 hardware. These registers are used for initialization, loading and verification of diagnostic microcode, starting and stopping the microcomputer, and diagnostic access. (Internal addresses are described in Appendix B of the TM78 Technical Manual.) 2-11 HH11/ HH70 RH20 BITS 50 20 52 21 15 14 13 12 11 10 9 8 6 5 4 3 2 0 INTERNAL ADDRESS INTERNAL DATA HOLD NOTES: 1. RH11/RH70 COLUMN REFERS TO BASE ADDRESS (172400) PLUS (OCTAL) NUMBER INDICATED. 2. RH20 COLUMN REFERS TO REGISTER SELECT BITS. 3. * INDICATES A READ-ONLY BIT. Figure 2-7 MA 6105 TM78 Hardware Control Register Fields A TM78 may be initialized by a MASSBUS INIT or by setting TM CLR (Figure 2-7). In either case, microcomputer terminates any commands previously loaded. New commands may not be loaded until TM RDY is set; this occurs after microcode initialization. The Drive Type register is valid only when TM RDY is set. TM CLR turns itself off after a short time, and may be considered write-only. The microcomputer may be stopped by setting the Hold bit. The stopped condition is indicated by the hold acknowledged (HLDA) bit after a small delay. The microprogram may be continued by clearing Hold. NOTE Clearing Hold may set MC PE. Therefore, a TM CLR or MASS BUS INIT should be performed afterward. The internal MB SEL bit must be loaded before restarting (initializing) from the HOLD state. A MASSBUS INIT clears Hold, but TM CLR does not (except for this difference, the two functions are identical within the TM78). When HLDA is set, the internal address structure of the TM78 may be accessed via Internal Address and Internal Data. If HLDA is not set, the Internal Address contains the current internal address asserted by the microcomputer. NOTE When HLDA is not set, Internal Address bits are constantly changing. The contents, therefore, may be undefined, or a parity error may be detected by the MASSBUS controller. Once HLDA is asserted, Internal Address may be loaded with the address of the location to be accessed. The location is read or written by Internal Data. The remaining four bits indicate situations that may interfere with proper communication between the microcomputer and the host CPU. They are listed and defined in Table 2-7. 2-12 Table 2-7 TM78 Hardware Control Register Error Bits Name Definition MCPE Microcomputer ROM parity error has occurred ILR Reference has been made to nonexistent MASSBUS register address CPE Parity error detected as a result of write to some MASSBUS register address EVPAR Diagnostic bit causes even parity to be generated and checked for on the MASSBUS control bus ILR and CPE also cause MB FAULT interrupt. The interrupt occurs when the microcomputer notices the error, which may be some time after the bit actually sets. 2.6 DUAL PORT One or two MASSBUSes may be connected to a TM78. The DUAL MB sense bit indicates dual port hardware. Each TU78 tape transport can be switched to either zero, one, or both ports. These conditions are indicated by the MAl NT, AVAIL and SHR sense bits. A tape unit is always available (A V AIL) if DUAL MB hardware is not installed. NOTE If the dual port option is not present, the tape unit is AVAIL when the TU78 port select switch is in any position except MAINT. All four bits (DUAL MB, AVAIL, SHR and MAl NT) are intended for system configuration purposes and error logging. If a port attempts to use a tape unit not switched to it, a NOT A VAIL interrupt is generated. The TM78 makes no attempt to synchronize a shared tape unit between operations from two ports. If two commands are active at one time, they are executed in an unpredictable sequence. Interrupts are returned to the MASSBUS that issued the command, except FAULT B and On-Line, which return to both MASSBUSes in a shared configuration. It is expected that if two separate processes are sharing a tape unit, they have an external path of resource-sharing intercommunication. Synchronization is performed through this external path. Processes not synchronized should never read a shared tape. Not only will records be received in random order, but error recovery operations may fail. Records may be written in an unsynchronized fashion only if ordering is not important. The TM78 does not respond to the MASSBUS port request sequence used by some other MASSBUS devices. 2.7 CHANNEL ADDRESS SUMMARY RHII and RH70 addresses, relative to the TM78, are summarized in Figure 2-8. RHI0, RH20, and RH780 addresses, relative to the TM78, are summarized in Figure 2-9. 2-13 UNIBUS *** ADDRESS 15 BASE sc I TRE +0 13 14 MCPEI 12 11 0 DVA I PSEL 10 9 8 6 A17 A16 IE RDY I 4 BUS ADDRESS 6 BYTE COUNT DLT I WCE 12 14 UPE I NED NEM I PGE DT. FAILURE CODE SER J FORMAT 3 o 2 GO MXF MDPE 0 DPR OR I IR CLR I PAT BAI I UNIT 3 ** DT. INTERRUPT CODE 0 RECORD COUNT I CMD ADR ATTENTION BIT 0 RDY I PRES ONL I REW PE I BOT EOT 0 FPT AVAILI SHR MAINTI DSE DATA BUFFER 22 24 PRINT FLGS 26 NSA I TAP 30 BCD SN 3 AUX PRINT NR 34 3 ** ERROR MSC; NR 32 0 DUALI MB I DATA PATTERN NR 0 DRIVE TYPE (101) WCS BCD SN 2 NDT FAILURE CODE 1 * DIAG TEST NR BCD SN 1 LOOpl (J'i) 0 EXPECTED DIAG DATA 36 BCD SN 0 1 .. DIAG REO ICOMP 1 .. ACTUAL DIAG DATA ATTN ADR 0 0 NDT INTERRUPT CODE 40 COMMAND COUNT 0 0 0 NDT FUNCTION CODEO GO 42 COMMAND COUNT 1 0 0 NDT FUNCTION CODEl GO 44 COMMAND COUNT 2 0 0 NDT FUNCTION CODE2 GO 46 COMMAND COUNT 3 0 0 NDT FUNCTION CODE3 GO 50 52 2 INTERNAL ADDRESS ™ TMI RDY CLR MC I ILR PE EV HLDA HOLD CPE I PAR 15 13 11 14 3,1 3 ** SKIP COUNT 16 20 4 DT. FUNCTION CODE WORD COUNT 2 10 5 12 10 9 8 INTERNAL DATA 6 5 4 3 2 2 o TYPE -1. COMMON ADDRESS SPACE (CAS) 2. TM78 HARDWARE CONTROL REGISTERS 3. RH11/RH70 REGISTERS DIAGNOSTIC USE ONLY SEE PDP-l1 PERIPHERALS HANDBOOK UNIBUS BASE ADDRESS = 172400 Figure 2-8 MA.£176 RH 11 and RH70 Address Summary 2-14 REGISTER SELECT 20 21 22 o 23 24 0 25 I I FORMAT 2 SER 3 PRINT FLGS 29 28 I 30 0 33 34 35 I CMD ADR RECORD COUNT 0 ATTENTION BIT 1• BYTE COUNT l ILJM~Ll 0 7 RDY\ PRES \ ONL \ REW 10 BCD SN 11 AUX PRINT NR PE 0 DRIVE TYPE (101) \wCS \ \ BOT \ EOT \ FPT AVAIL SHR MAINT\ BCD SN 2 3 DATA PATTERN NR I LOOP OV 0 0 0 0 BCD SN 0 o I COMP EXPECTED DIAG DATA 1• DIAG REO ACTUAL DIAG DATA 1 ATTN ADR NOT FAILURE CODE DSE BCD SN 1 0 0 1• NOT INTERRUPT CODE 14 COMMAND COUNT 0 0 0 NOT FUNCTION CODE 0 GO 15 COMMAND COUNT 1 0 0 NOT FUNCTION CODE 1 GO 16 COMMAND COUNT 2 0 0 NOT FUNCTION CODE 2 GO 17 COMMAND COUNT 3 0 0 NOT FUNCTION CODE 3 GO 20 21 TM \ CLR TM \ MC ROY PE 15 14 TYPE GO DT INTERRUPT CODE 0 IDPR DIAG TEST NR NSAITAP 13 32 ERROR MSG NR 6 12 31 DT FUNCTION CODE SKIP COUNT 4 5 27 0 DT FAILURE CODE 1 26 OVA I 13 I ILR 2 INTERNAL ADDRESS CPE \ P~R \HLDA\ HOLD 12 11 10 9 8 INTERNAL DATA 6 5 4 3 2 2 o TYPE 1. COMMON ADDRESS SPACE 2. TM78 HARDWARE CONTROL REGISTERS * DIAGNOSTIC USE ONLY MA·6175 Figure 2-9 RH 10, RH20, and RH780 Addresses 2.8 INTERRUPT CODE FAILURE CODE CROSS-REFERENCE AND SUMMARY The tables which follow summarize the contents of this chapter. The list below describes each table. Table 2-8 2-9 2-10 2-11 2-12 Description Interrupt Code to Failure Code Non-data Transfer (NDT) Interrupts to NDT Commands Data Transfer (DT) Interrupts to DT Commands TM78 Initiated Interrupts Host Responses 2-15 Table 2-8 Interrupt Code to Failure Code Int Code Name Use Failure Code 01 DONE. NDTor DT 00 Extended sense data not updated 01 Extended sense data updated and contains something of interest 02 TM NDTor DT Always zero 03 BOT NDTor DT 01 Command was issued with tape at BOT 02 Saw BOT indicator after tape motion started 03 ARA ID detected 00 Extended sense data not updated 01 Extended sense data updated and contains something of interest 04 EOT NDTor DT 05 LEOT NDT Always zero 06 NOOP NDT Always zero 07 REWINDING NDT Always zero 10 FPT NDTorDT Always zero 11 NOT RDY NDTor DT 01 TU is on-line but not ready (Possible when TV is manually rewound or loading) 02 Fatal error has occurred and this command cannot be performed until error status has been presented and a TM CLEAR received 03 Access to TV is allowed but TV is either rewinding or doing a DSE from another MASSBUS or keypad command 12 NOT AVAIL NDTor DT Always zero 13 OFF LINE NDTorDT Always zero 14 NON EX NDTor DT Always zero 15 NOT CAPABLE NDTor DT 01 No record found within 25 ft (7.6 m) of tape 02 ID Burst neither PE or GCR 03 ARA ID not found 04 No GAP found after ID Burst (PE) or ARA ID Burst (GCR) 2-16 Table 2-8 Interrupt Code to Failure Code (Cont) Int Code Name Use Failure Code 17 ON LINE TM INIT Always zero 20 LONGREC DT 00 Extended sense data not updated 01 Extended sense data updated and contains something of interest 00 Extended sense data not updated 01 Extended sense data updated and contains something of interest 01 CRC error, ACRC error, pointer mismatch, un correctable or two track error set in ECCSTA register (This code generated by write GCR operations) 02 CRC error, ACRC error or un correctable set in ECCSTA register (This code generated by read GCR operations) 03 Un correctable error set in ECCSTA register (This code generated by read PE operations) 04 AMTIE, pointer mismatch, uncorrectable, two track error or single track error set in ECCSTA register (This code generated by write PE operations) 05 At least one bit set in ECCST A register 06 At least one Write Fail bit set in RPF AIL and RP ATH registers (This code generated by write PE operations) 07 More than one Write Fail bit set in RPF AIL and RPATH registers (This code generated by write GCR operations) 10 RST AT contains bad code 11 CRC characters from WMC and RMC do not match (This code generated by write PE operations) 12 MASSBUS data bus parity error 13 Record length incorrect during retry opposite attempt; invalid data has been transferred 21 22 SHORT REC RETRY DT DT 23 READ OPP DT Same as Int Code 22 24 UNREADABLE DT Same as Int Code 22 2-17 Table 2-8 Interrupt Code to Failure Code (Cont) Int Code Name Use Failure Code 25 ERROR DT Same as Int Code 22 26 EOT ERROR DT Same as Int Code 22 27 BAD TAPE NDTorDT Same as Int Code 22 30 TM FAULT A NDT or DT 01 Illegal command code 02 Data transfer command issued while non-data transfer command in progress on same tape unit 03 WMC error; check Encode register for reason. May be Illegal Format or Skip Count codes 04 RUN not received from MASSBUS controller 05 Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated in selected function routine) 06 ECC ROM parity error 07 XMC ROM parity error 10 Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Verify ID Burst command loaded during write of BOT area) II Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Verify ARA Burst command loaded during write of BOT area) 12 Command read from RMC register RCMDP did not match command loaded into RCMD register (This code generated when Verify ARA ID command loaded during write of BOT area) 13 Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Verify Gap command loaded during write BOT area) 2-18 Table 2-8 Int Code Name Interrupt Code to Failure Code (Cont) Vse Failure Code 14 - 15 16 31 TVFAVLTA NDTor DT Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Read ID Burst command loaded during read of BOT area) Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Verify ARA ID command loaded during read of BOT area) - Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Verify Gap command loaded during read of BOT area) 17 Command read from RMC register RCMLP did not match command loaded into RCMD register (This code generated when Find Gap command loaded during Erase Gap routine) 20 WMC LEFT failed to set in Extended Sense routine 21 XL PE set in INTSTA register 22 XMC DONE did not set 23 WMC ROM PE or RD PE set in WMCERR register 01 TV Status parity error 02 TV Command parity error 03 Rewinding tape went off-line 04 Tape went not ready during DSE 05 TV CMD status changed during DSE 06 TV velocity never came up to speed 07 TV velocity changed after up to speed and writing started 10 - TV CMD did not load correctly to start tape motion in selected function routine II 2-19 TV CMD did not load correctly to set drive density Table 2-8 Int Code Name Use Interrupt Code to Failure Code (Cont) Failure Code 12 TU CMD did not load correctly to start tape motion to write BOT ID Burst 13 TU CMD did not load correctly to backup tape to BOT after failing to write BOT ID 14 Failed to write density ID Burst correctly 15 Failed to write ARA Burst correctly 16 Failed to write ARA ID correctly 17 ARA error bit set -in MTA Status B register 21 Could not find a gap after the ID code was written correctly 22 TV CMD did not load correctly to start tape motion to read ID Burst 23 Time-out looking for BOT after detecting ARA ID Burst 24 Failed to write Tape Mark correctly 25 Tape never came up to speed while trying to reposition for retry of writing Tape Mark 26 TV CMD did not load correctly to start tape motion in Erase Gap routine 27 Could not detect a gap in Erase Gap routine 30 Could not detect a gap after writing record 31 Read path terminated before entire record was written 32 Could not find a gap after writing record and read path terminated early 33 TV CMD did not load correctly to backup for retry of Write Tape Mark 34 TV velocity changed after up to speed while trying to reposition for retry of writing Tape Mark 35 TV CMD did not load correctly to backup to retry a read of BOT ID 36 2-20 Time-out looking for BOT after failing to write BOT ID Table 2--8 Int Code 32 Name TM FAULT B Interrupt Code to Failure Code (Cont) Use TM INIT Failure Code 37 TU velocity changed while writing PE gap before starting to write record 40 TU CMD did not load correctly to set PE tape density at start of write BOT ID Burst 41 TU CMD did not load correctly to set GCR tape density after writing Density ID 42 TU CMD did not load correctly to set PE tape density at start of read from BOT 43 TU CMD did not load correctly to set GCR tape density after reading a GCR Density ID Burst 00 RSTO interrupt occurred with TM RDY still set 01 Power failed to interrupt 02 Interrupt for unknown reason on channel 5.5 03 Interrupt for unknown reason on channel 6.5 04 Interrupt for unknown reason on channel 7 05 Interrupt for unknown reason on channel 7.5 06 CAS contention retry count expired 07 CAS Contention error not retryable 10 Queue error; could not find queue entry 11 Queue entry already full 12 8085 ROM parity error 13 In-line test 0; WMC self test failed = M8959-M8957 14 - In-line test 1 ; XMC ROM parity error M8958-M8959-M8960 15 In-line test 2; RPM self test failed M8953-M8960 16 In-line test 3; RPM 1 channel 0 self test failure M8950 (slot ABI2) 17 In-line test 4; RPM 1 channell self test failure M8950 (slot ABI3) 2-21 Table 2-8 Interrupt Code to Failure Code (Cont) Int Code Name Use Failure Code 20 - 21 In-line test 5; RPM 1 channel 2 self test failure M8950 (slot ABI4) In-line test 6; RPM 1 channel 3 self test failure M8950 (slot AB 15) 22 - In-line test 7; RPM 1 channel 4 self test failure M8950 (slot AB 16) 23 - In-line test 10; RPMl channel 5 self test failure M8950 (slot CDI3) 24 - In-line test 11; RPM 1 channel 6 self test failure M8950 (slot CD 14) 25 - In-line test 12; RPM 1 channel 7 self test failure M8950 (slot CD 15) 26 - In-line test 13; RPM 1 channel P self test failure M8950 (slot CD 16) 27 - In-line test 14; RPMl error correction self test M89 50-M89 51-M89 53 30 - In-line test 15; 40000-40777 RAM memory failure M8960 31 In-line test 16; 41000-41777 RAM memory failure M8960 32 - In-line test 17; 42000-42777 RAM memory failure M8960 33 - In-line test 20; 43000-43777 RAM memory failure M8960 34 - In-line test 21 ; 44000-44777 RAM memory failure M8960 35 - In-line test 22; 45000-45777 RAM memory failure M8960 36 - In-line test 23; 46000-46777 RAM memory failure M8960 37 - In-line test 24; 47000-47777 RAM memory failure M8960 40 - In-line test 25; loop write to read at TV port 0 -GCR In-line test 26; loop write to read at TV port 0 - PE 41 2-22 Table 2-8 Int Code Name Use Interrupt Code to Failure Code (Cont) Failure Code 42 - In-line test 27; loop write to read at TU port 1- GCR 43 - In-line test 30; loop write to read at TU port 1 - PE 44 - In-line test 31 ; loop write to read at TU port 2-GCR In-line test 32; loop write to read at TV port 2 - PE 45 46 - In-line test 33; loop write to read at TV port 3-GCR 47 - In-line test 34; loop write to read at TV port 3 - PE 50 - In-line test 35; loop write to read at MT A 0 -GCR In-line test 36; loop write to read at MTA 0 - PE 51 52 34 MB FAULT - In-line test 37; loop write to read at MTA I -GCR 53 In-line test 40; loop write to read at MTA I - PE 54 In-line test 41 ; loop write to read at MT A 2 -GCR 55 - In-line test 42; loop write to read at MTA 2 - PE 56 - In-line test 43; loop write to read at MTA 3 -GCR 57 In-line test 44; loop write to read at MTA 3 - PE 01 Control bus parity error 02 Illegal register referenced 2-23 Table 2-8 Int Code Name 77 KEY FAIL Interrupt Code to Failure Code (Cont) Use Failure Code 02 - TM78 not off-line 03 Illegal instruction code 04 Microdiagnostic start or continue command issued 05 Table 2-9 Keypad entry error 01 - Microdiagnostic loop on error command issued Non-Data Transfer (NDT) Interrupts to NDT Commands NDT Interrupt Possible NDT Commands Host Response * DONE Any except NO OP A TM SP FWD REC, SP REV REC B BOT SP REV REC, SP REV FILE, SP REV EITHER B,O EaT WTM PE, WTM GCR, ERG, Close File C LEOT SP FWD FILE/LEOT D FPT WTM PE, WTM GCR, ERG, Close File, DSE E NOT RDY Any except NO OP and Sense F NOT AVAIL Any except NO OP and Sense G OFF LINE Any except NO OP and Sense H,F NON EX Any except NO OP and Sense G NOOP NOOP A BAD TAPE Any except NO OP, Sense, DSE, Rewind, Unload I, J, G TMFAULT A Any J, G TUFAULT A Any J, G REWINDING Rewind U NOT CAPABLE Any space command G,T *See Table 2-12 2-24 Table 2-10 Data Transfer (DT) In terrupts to DT Commands DT Interrupt Possible DT Commands Host Response * DONE Any A EOT Write PE, Write GCR C LONG REC Read Fwd, Read Rev L,K SHORT REC Read Fwd, Read Rev L RETRY Any with SER=O M READ OPP Read Fwd, Read Rev with SER=O P NOT CAPABLE Read Fwd, Read Rev G,T UNREADABLE Read Fwd, Read Rev with SER=Q I, J BAD TAPE Any with SER=O I, J, G ERROR Any with SER=l N EOTERROR Write PE, Write GCR with SER= 1 N TM Read Fwd, Read Rev B BOT Read Rev B,O FPT Write PE, Write GCR E NOT RDY Any F NOT AVAIL Any G OFF LINE Any H,F NON EX Any G TM FAULT A Any J, G TUFAULT A Any J, G *See Table 2-12 2-25 Table 2-11 TM78 Initiated Interrupts TM Interrupt Host Response* ON LINE S TM FAULT B J, R TU FAULT B J, R MB FAULT J, R *See Table 2-1 2 Table 2-12 Host Responses Host Response Meaning A Return "operation complete" B Stop any look-ahead buffering; Return "end of file reached" c Return "end of tape" error (Never rely on the physical relationship between EOT and record location, since this can change between units) D Return "logical end of tape", or other appropriate action E Return "illegal write" F Retry operation after receiving a TM78 initiated interrupt for that tape unit G Return "device error" II Inform operator of condition Return "data error" J Enter Failure Code in the system error log K Return "record is longer than user requested" L Set "incorrect record length" status; Obtain actual size from Byte Count location M Repeat previous operation, starting at record in error N User performs his/her own error recovery algorithm, if any o Set "beginning of tape" status 2-26 Table 2-12 Host Response Meaning p Read opposite Host Responses (Cont) 1. Use Record Count to dequeue any records which were correctly transferred. Load Record Count with O. 2. Byte Count now contains the TM78 best guess of the actual record length. Use this value to recompute the memory buffer address and Skip Count. Byte Count does not need to be reloaded. If record does not fit in buffer, compute number of words for data channel to skip, or perform response I. 3. Issue READ FWD or READ REV command. Use command opposite the initial direction before any errors occurred. 4. Follow correct response to resulting interrupt code. The TM78 returns a DONE or possibly a SHORT REC interrupt code when record is correctly read and positioned in memory. R Issue a TM CLEAR, unless retry count exceeded; Reissue all commands for which interrupts have not been received, Update retry count S Continue any processes that were waiting for this tape unit T Invoke tape labeling procedure for handling blank tape U Flag the tape unit as busy; Expect a future done interrupt 2-27 CHAPTER 3 INSTALLATION 3.1 SITE PLANNING AND CONSIDERATIONS Since the TM78 is always contained within a transport cabinet, site planning is accomplished when the cabinet is considered. The additional power required to supply the TM78 is 700 W. 3.2 UNPACKING Likewise, there are no unpacking instructions for the TM78 because it is mounted inside the master transport cabinet. The TM78 cables may be shipped separately and are the only items that must be unpacked. 3.3 INSPECTION Perform inspection of the TM78 according to the following procedures. 1. Check that the TM78 is securely mounted to the frame members inside the transport cabinet. Ensure that there is no apparent damage to the backplane (cracks, bent pins, etc.). 2. Remove the four 10-32 screws (Figure 3-1) securing the left side of the TM78 gate, and swing it out on its hinge. Loosen the two logic cover retaining screws (Figure 3-2), and remove the cover. 3. Check that all circuit modules are firmly seated in their correct locations (Figure 3-3). 4. Replace the logic cover, and tighten the retaining screws. TM78 LOGIC GATE REMOVE FOUR---10-32 SCREWS MA-6157 Figure 3-1 Releasing TM78 Logic Gate 3-1 :lJ o ~ en o .." 60· ..,c:: » c:c (") M8950 (RC P) M8950 (RC4) c; M8950 (RC 7) M8950 (RC3) (l'I M8950 (RC6) M8950 (RC 2) ~ M8950 (RC 5) M8950 (RC 1) w MS952 (CRCi M8950 (RCO) 1\,)1 .." 00· ..,c:: ('D w N ('D '-f w ..., W I tv ~ -..) M8951 (ECC) M8953 (RMC) M8955 (TU PORT)_ _ ('D 3 0 (PORTS 2,3) 00 c:: ~ : 18r C ::;: ~ 0 0- M8955 (TU PORT) 1 BI ANK M8959 M8958 (PORTS 0,1) colZ Ul ..., ~ 00 (WMC) 0) l' (8MC) (l'I (JQ M8960 '"-<:: 0 M8957 (MBC) (PORT B OPTIONAL) M8956 (MBD) (PORT B OPTIONAL) w M8957 (MBC) (PORT A) M8956 (MBD) (PORT A) c:: ..... :s. ::s (JQ -..) (XMC) l' ~ ;;0 .j>. I\,) 0 o· (J 0 <: .., ('D MASSBUS B TERMINATOR (OR CABLE OUT) MASSBUS A TERMINATOR (OR CABLE OUT) MASSBUSA LOCK LEVER (SHOWN IN UNLOCKED POSITION) ~ CABLE - - - - MA-6159 Figure 3-4 MASS BUS Cable Terminator Connections 3.4 INSTALLATION PROCEDURES Installation consists of cabling as many as four BC06S cables to the TM78. The number of cables depends upon the number of MASSBUS ports and whether additional MASSBUS devices are to be connected to the same MASSBUS controller. A dual ported TM78 may require field installation of dual port logic. Paragraph 3.4.3 describes the procedures for installing the dual port logic. Installation also comprises setting the appropriate TM78 drive address(es). NOTE If the TM78 cables are already installed, omit the steps outlined in Paragraphs 3.4.1 and 3.4.2. 3.4.1 MASS BUS Cabling Perform the installation of MASSBUS cabling according to the following procedures. 1. Connect one end of the 25 ft (7.6 m) MASSBUS cable to the port A input jack (118) at the rear of the logic gate assembly (Figure 3-4). 2. Lock the connector in place by turning the lock lever 90 degrees clockwise to a horizontal position. 3. If no other MASSBUS device is to be connected, terminate the cable by plugging the MASSBUS terminator provided (PN 70-09938) into the port A output jack (117). 4. Position the MASSBUS cable as shown in Figure 3-5, and secure it to the logic gate and frame assembly with the six cable clamps and hardware provided. 5. Connect the opposite end of the MASSBUS cable to the distribution panel at the rear of the host computer system. 3-3 MASSBUS CABLE MA-6160 Figure 3-5 MASSBUS Cable Routing and Hardware 3.4.2 TU Bus Cabling The radial tape unit bus is made up of two flat cables (PIN 70-17382-15). Figure 3-6 shows how these cables are routed electrically. Note that each transport has a unique set of cables, and the jacks to which they are connected (on the TM78) determine the unit number. Figure 3-7 shows the physical placement of the cables within the T~178. To route the cable pair, first remove two cable retainers. Then, the cables are formed and laid, and the retainers are replaced. If there are multiple cable pairs, the pair for the highest tape unit number must be installed first, and the pair for the lowest tape unit number installed last. In other words, work from jack J8 toward jack Jl so that all cables lay flat. Place the connectors so that the colored stripes on the cables are toward the MASSBUS jacks. For information on cable routing in the transport, refer to the installation chapter in the TU78 User Guide. 3.4.3 TM78-C Optional Dual Port Logic A master dual port TU78/TM78 subsystem may be shipped from the factory as a single port subsystem, with dual port logic in a separate container. Or an existing single port master may be upgraded to dual port at a later date in the field. In either case, the procedure below must be followed in order to create a dual-ported master. 1. Inspect the contents of the upgrade kit. The following system-tested components should be included: one M8956 MASSBUS data module, one M8957 MASSBUS control module, one 25 ft MASSBUS cable, and one MASSBUS terminator. 2. Gain access to the logic cage by following the steps in Paragraph 3.3. 3. Insert the M8956 and M8957 modules into backplane slots 3 and 4, respectively (Figure 3-4). 4. Replace the logic cover. 3-4 TU BUS OA TU BUS OB ooco TU BUS lA TUBUS1B J3 J2 TU BUS 2A TU 2 MIA TU BUS 2B DDDD J3 J2 TU BUS 3A TU 3 MIA TU BUS 3B 0000 MA·6172 Figure 3-6 Radial TU Bus Connections 5. Follow the steps in Paragraph 3.4.1 for running the MASS BUS cable, and connect it to the port B input jack (J20). Connect the cable terminator to the port B output jack (J 19) (Figures 3-4 and 3-5). 6. Connect the opposite end of the MASSBUS cable to the distribution panel at the rear of the host computer system. 7. Set the port B drive address switches (Paragraph 3.4.4). 8. Verify the integrity of the dual port logic by running the appropriate control logic diagnostic from the computer connected to port B. 3.4.4 Setting MASS BUS Drive Address The drive address for both MASSBUS ports is set into a small DIP switch mounted on the TM78 backplane. (Refer to Figure 1-5 for the location of this switch.) Figure 3-8 shows the eight individual switches contained within the DIP switch and their functions. Locate the three address-determining switches for the appropriate MASS BUS port. The three switches (A2:0) form a 3-bit binary field for a maximum of eight drive addresses. To set an address bit, press the switch in on the left side ( 1 side). To clear an address bit, press the switch in on the right side. Thus, for drive address 0, all three would be set to 0; for drive address 1, only AO would be set to 1, and so on. 3-5 FROM H7422 POWER SUPPLY , CABLE RETAINER RED STRIPE CABLE RETAINER MA-6161 Figure 3-7 TU Bus Cable Routing and Hardware D MASSBUS PORT A ( MASSBUS PORT B ( •• •• •• •• •• •• •• •• ON/OFF LINE AD Al A2 ON/OFF LINE AD A 1 A2 MA6101 Figure 3-8 MASSBUS Port AlB Drive Address Selector Switch 3-6 The on/off-line switches are used for maintenance purposes only. To electrically remove one or both ports of a drive from the host system(s), push the appropriate switch in on the right side. The normal position for these switches is the on-line, or left position. Taking one of two ports off-line does not necessarily mean that a given transport is off-line; the transport may be switched to the opposite port through its control panel port selector switch. NOTE If the dual port option (port B) is not present in the TM78, the lower set of four switches has no effect. 3.5 ACCEPTANCE TESTING The TM78 acceptance tests are run concurrently with the master TU78 acceptance tests. Refer to the subsystem acceptance procedures found in Paragraph 3.5 of the TU78 User Guide or TU78 Technical Manual. 3-7 APPENDIX A EXTENDED SENSE COMMAND (73) DATA BYTES BYTE DESCRIPTION 1. Command code being executed on last error 2. Interrupt code from last error 3. Failure code from last error 4. Hardware register 0; read path write fail bits 5. Hardware register 1; read path diagnostic bits 6. Hardware register 2; read path status 7. Hard ware register 3; read path command loop 8. Hardware register 20; AMTIE 9. Hardware register 21; RC DONE 10. Hardware register 22; illegal 5-4 11. Hardware register 23; mark 2 12. Hardware register 24; end mark 13. Hardware register 25; RC PAR bits 14. Hardware register 26; postamble det 15. Hardware register 27; data 16. Hardware register 30; CRC 17. Hardware register 31; corrected data 18. Hardware register 32; ECC status 19. Hard ware register 40; channel 0 TIE bus 20. Hardware register 41 ; channel 1 TIE bus A-I BYTE DESCRIPTION 21. Hardware register 42; channel 2 TIE bus 22. Hardware register 43; channel 3 TIE bus 23. Hardware register 44; channel 4 TIE bus 24. Hardware register 45; channel 5 TIE bus 25. Hardware register 46; channel 6 TIE bus 26. Hardware register 47; channel 7 TIE bus 27. Hardware register 50; channel P TIE bus 28. Hardware register 60; TIE bus 29. Hardware register 104; AMTIE 30. Hardware register 110; PORT status 31. Hardware register 114; read data 32. Hardware register 240; CAS status 33. Hardware register 241; CBUS status 34. Hardware register 300; DBUS status 35. Hardware register 320; WMC status 36. Hardware register 321; TU select 0 37. Hardware register 322; TU select I 38. Hardware register 323; write data 39. Hardware register 324; byte counter <7:0> 40. Hardware register 324; byte counter <15:8> 41. Hardware register 325; PAD counter <7:0> 42. Hardware register 325; PAD counter <15:8> 43. Hardware register 326; ECODE counter <7:0> 44. Hardware register 326; ECODE counter <15: 8> 45. Hardware register 330; DDR/MBD A A-2 BYTE DESCRIPTION 46. Hardware register 331; DDR/MBD B 47. Hardware register 332; WMC errors 48. Hardware register 340; interrupt status 49. MIA register 0; TU78 status 50. MIA register 1; MIA status A 51. MIA register 2; MIA status B 52. MIA register 3; serial NR A 53. MIA register 4; serial NR B 54. MIA register 5; TU diag 55. Retry counter (RETCNT). This byte is the count of retry interrupt requests given for the tape unit. When this count is zero, the tape unit is not in a retry sequence. 56. Retry control bits (RETCNT+ I). This byte is used by the microcode to control error recovery. It is meaningful only when the retry counter (byte 55) is not zero. Bit 5 - set when initial command moved in the reverse direction Bit 6 - set when initial command was a read Bit 7 - set when last retry requested was in opposite direction of initial command 57. TU software status (TUx). This byte contains information about the tape drive. Bit 0 - set when a data security erase command is in progress Bit 1 - set when a rewind command is in progress Bit 2 - set when tape unit exists and power is on Bit 3 - set when a non-data transfer command issued from a MASSBUS port is in progress Bit 4 - set when tape was last moved in the reverse direction Bit 5 - set when last tape operation involved writing on tape Bit 6 - set when last record seen was a tape mark Bit 7 - set when last MASSBUS command came from port B A-3 BYTE DESCRIPTION 58. Transfer control word (XFRCTL). This byte contains control information used by data transfer commands. Bits 0-2 - write clock select Bits 3-5 - read clock select Bit 6 - PLO bypass Bit 7 - low read threshold 59. Retry suppress and format control (XRETRY). This byte contains the contents of the left half of the MASSBUS register, which contains the retry suppress bit, format, and skip count. 60. Keypad enable flag (ENAON). This byte is not zero when the keypad is enabled. NOTE The contents of bytes 4 through 48 are described in Appendix B of the TM78 Technical Manual. The contents of bytes 49 through 54 are described in Appendix C of the TM78 Technical Manual. A-4 TM78 MAGNETIC TAPE FORMATTER USER GUIDE EK-OTM78-UG-001 Reader's Comments Your comments and suggestions will help us in our continuous effort to improve the quality and usefulness of our publications. What is your general reaction to this manual? w~lwritten,ett? In your judgement is it complete, accurate, well organized, Isiteasytouse?~~~~~~~~~~~~~~~~~~~~~~~~~~~ What features are most useful?_~~_ _ _ _ _~_~~_ _~~~~_~_~~~~~~~_ What faults or errors have you found in the manual?_~~_~_ _~_ _ _~~_",,---~~~~~~ Does this manual satisfy the need you think it was intended to satisfy?~~~~~~_~~~_~__ Does it satisfy your needs? _ _ _ _ _ _ _ _ _ _ Why? _ _ _ _ o ~ _________ ~ _ __ Please send me the current copy of the Technical Documentation Catalog, which contains information on the remainder of DIGITAL's technical documentation. Name _ _ _ _ _ _ _ _ _ _ _ _ ____ Street ___~~~~~~~~~~~~~_ _ City _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ Title ___ ____ ___ Company __~~~~_ _ _~_ _ _ _~_~___ State/Country _ _ _ _ _ _ _ _ _ _ _ _ __ Department _~_~~~_~~_ _~_~~_ Zip_~_~~~~~~~~~~~~~~___ ~_~ _~~ ~ ~~ ~~ ~_ Additional copies of this document are available from: Digital Equipment Corporation Accessories and Supplies Group Cotton Road Nashua, N H 03060 Attention Documentation Products Telephone 1-800-258-1710 Order No. EK·OTM78-UG·001 1____________________ Fold H e r e - - - - - - - - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ 00 Not Tear - Fold Here and Staple - - - - - - - - - - - - - - - - momoomo 111111 ~ ~_R~_T_~_LA_~~~-E~S~PE~~~MI~TR~NO~~~3~~L=Y~M-AY-~-A.!,I_M~_. __ __ _____________________]. POSTAGE WILL BE PAID BY ADDRESSEE Digital Equipment Corporation Educational Services Development and Publishing 129 Parker Street, PK3-1 IT 12 Maynard, MA 01754 No Postage Necessary if Mailed in the United States
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies