12-09340-00
June 1973
1 pages
Original
0.1MB
view
download
Document:
H605
Order Number:
12-09340-00
Revision:
0
Pages:
1
Original Filename:
H605.pdf
OCR Text
Engineering Change Order Log PROCESSOR TYPE LA30 Motor Drive Amplifier All cs: CODE: D H605-00001 C ETCH: D APR-71 - CORRECTION: Relocate diode Dl and resistor R3 to provide clearance for resistor Rl. In-plant effectivity -03 rework immediately H605-00002 CODE: P cs: D NOV-71 - CORRECTION: Change part number on drawings and Parts List from 12-09340 to 12-09340-00 to ensure proper MATE-N-LOCK connector is used. In-plant effectivity -06 documentation change H605-D0003 CODE: F cs: E FEB-73 - PROBLEM: Hot diodes result in discoloration of printed circuit board. CORRECTION: Raise diodes so that they do not touch the board. In-plant effectivity -03 rework immediately Field effectivity -Exchange H605's in LA30's as required; replace a CS revision "c .. board with CS revision "D ". ( Time To Install And Test 1.5 Hours. ) ( Kit Contents -FCOlPrints And Parts) H605-00004 CODE: D H605 cs: F H605-0006A CODE: D SEP-73 - PROBLEM: Redundancy has occurred in ECO changes; revision levels are incorrectly specified. CORRECTION: Cancel ECO H605-00006. In-plant effectivity -Cancelled H605-00007 CODE: D cs: J SEP-73 - PROBLEM 1: Irregular performance of carriage due to G936 and carriage tolerance. CORRECTION 1: Replace 39 ohm resistor with a 43 ohm resistor. PROBLEM 2: Documentation is incorrect with regard to revision level. CORRECTION 2: Revision letter is updated to reflect correct level. NOTE: See correction supplement H605-OOO7A. In-plant effectivity -Retrofit all H605's from Puerto Rico by June 22; all H605's at Westfield and Westminster if problem is present. H605-0007A CODE: D JUL-73 - CORRECTION: There were typographical errors on sheet 1 of ECO H605-OO007; that sheet is superseded by sheet 1 of supplement ECO H605-0007A. In-plant effectivity -Unchanged ETCH: E MAR-73 - PROBLEM: Hot diodes result in discoloration of the printed circuit board and failure of the diodes. CORRECTION: Redesign board to give large heatsink area under diodes; add transistor. In-plant effectivity -02 phase-in by May I, 1973 H605-C0005 CODE: F cs: H APR-73 - PROBLEM: Diodes on board are running HOT resulting in discoloration of the board. CORRECTION: Raise diode D8 ; add heat sinks to 08 and D9. NOTE: See continuation supplement FCO H605-C005A. In-plant effectivity -03 • retrofit all units that have not been shipped. Field effectivity -Rework all H605's if symptoms are present. ( Time To Install And Test 1.0 Hour. ) ( Kit Contents -FCOlPrints And Parts) H605-C005A CODE: F cs: El SEP-73 - CORRECTION: The CS revision level of all etch revision "A .. thru "D .. boards, retrofitted with heat sinks, will be "El ". Either heat sink clip #12-11361 or #90-07203 can be used, depending on availability. No boards after etch revision "E .. will be retrofitted with heat sinks. In-plant effectivity -Retrofit immediately, as of October I, 1973. Field effectivity -Retrofit immediately H605-00006 CODE: D JUL-73 - PROBLEM: Unavailability of copper heat sink and excessive cost of same, #12-11361. CORRECTION: Allow parts substitution with beryllium copper clip, #9007203; either heat sink may be used. NOTE 1: Heat sink clips are to be used on etch revision "0 .. boards only. NOTE 2: This ECO is cancelled by supplement ECO H605-0006A. NOTE 3: CS revision "El ", ordered by this ECO, was cancelled by ECO H605-0006A. In-plant effectivity -02 phase-in as of 5-31 Copyright © 1973 by Digital Equipment Corporation. Printed in U.S.A. PAGE 1
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies