DECserver 300 Software Installation VMS Jun89
Order Number:
AA-NE45A-TE
Revision:
0
Pages:
65
Original Filename:
AA-NE45A-TE_DECserver_300_Software_Installation_VMS_Jun89.pdf
OCR Text
DEC server 300 Software Installation (VMS) Order No . AA-NE45A-TE DECserver 300 Software Installation (VMS) June 1989 This manual explains how to install the DECserver 300 distribution software onto VMS systems, how to configure these systems as a down-line load hosts, and how to down-line load the DECserver 300 image. This manual is intended for the VMS system manager or the network manager. Supersession/Update Information: This is a new manual. Operating System and Version: VMS VS.O Software Version: DECserver 300 V1.0 This manual applies to Version 1.0 of the DECserver 300 software and Version S.O of the VMS operating system, and all subsequent maintenance releases up to the next major product release. Order Number: AA-NE45A-TE AA-NE45A-TE June 1989 The information in this document is subjectto change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software described in this document is furnished under a license and may only be used or copied in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Digital or its affiliated companies. Copyright © 1989 by Digital Equipment Corporation All Rights Reserved. Printed in U.S.A. The following are trademarks of Digital Equipment Corporation: DEBNA DEBNET DEC DESVA DECconnect DECnet LAN Bridge LA120 ThinWire DECserver LN01 ULTRIX-32 DECUS LN03 LQP02 MASSBUS Micro/RSX MicroVAX UNIBUS PDP VMS DELNI DELUA DELQA DEMPR DEQNA oESOA Q-Bus DEUNA mOmDOmO JM Rainbow RSX RSX-11 M-PLUS VAX VAXcluster VAXmate VAXstation Professional This manual was produced by Networks and Communications Publications. Contents Preface 1 Installation Overview 1.1 1.2 1.3 1.4 1.5 2 Installation Flow Chart ..................... . . . . . . . 1-1 Installing the Distribution Software ................... 1-4 Configuring the Load Host's Node Database ........... 1-4 Verifying the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Prerequisite and Optional Products . . . . . . . . . . . . . . . . . . . 1-6 Installing the Distribution Software 2.1 2.2 2.3 2.3.1 2.3.2 2.4 Preparing for Installation ........................... 2-1 Installing on the PriInary Load Host .................. 2-2 Installing onto Alternate Load Hosts .................. 2-9 Installing onto Single Systems .................... 2-10 Installing onto Other Operating Systems ............ 2-10 After Exiting VMSINSTAL ........................ 2-10 iii 3 Configuring the Load Host's Node Database 3.1 3.2 3.2.1 3.2.2 3.2.3 3.3 3.4 4 Preparing for Configuration. . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Configuring on the Load Host ....................... 3-3 List Known DECservers (Option 1) ................. 3-6 Add a DECserver (Option 2) ...................... 3-6 Options 3, 4, and 5 ............................. 3-8 Verifying a Merge on VAXcluster Nodes ............... 3-8 Exiting DSVCONFIG .............................. 3-9 Verifying the Installation 4.1 4.2 Verifying the Load Host Installation .................. 4-1 Verifying the Server System Installation ............... 4-2 A DECserver 300 Distribution Files B Using the Remote Console Facility C Examples: Installation, Configuration, Verification C.1 C.2 C.2.1 C.2.2 C.2.3 C.2.4 C.2.5 C.2.6 C.3 C.3.1 iv Example of an Installation. . . . . . . . . . . . . . . . . . . . . . . .. C-1 Example of a Configuration. . . . . . . . . . . . . . . . . . . . . . .. C-4 Starting DSVCONFIG.COM ..................... C-5 Listing Known DECservers (Option 1) .............. C-5 Adding a DECserver (Option 2) .................. C-6 Swapping an Old Terminal Server for a New Terminal Server (Option 3) .............................. C-6 Deleting a DECserver from the Database (Option 4) . .. C-7 Restoring Existing DECservers to the Database (Option 5) .......................................... C-7 Example of Verification: Verifying a Load Host Installation C-7 Using RCF and Warning Server Users ............. C-7 C.3.2 C.3.3 C.3.4 C.3.5 C.3.6 C.4 Enabling DECnet Event Logging and Checking Server Names ...................................... C-8 Down-Line Loading with the LOAD Comlnand ...... C-9 DECnet Event-Logging Display after Issuing LOAD ... C-9 Checking the Service Circuit ..................... C-I0 Conclusion of a Load Host Installation Verification .... C-l1 Example of Verification: Verifying the Server System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-l1 Index Figures 1-1 1-2 Terminal Server Software Installation Flow Chart .......... 1-2 Load Host Node Database Configuration ................ 1-5 v Preface This installation manual explains how to: • Install the DECserver 300 distribution software onto a VMS system running DECnet Phase IV so that this systetn can perfonn as a load host. The load host can be a single system or a member node of a VAXcluster. • Configure the load host's node database. • Verify the installation by first down-line loading the server image to the DECserver 300 terminal server and then testing a few server COlnmands. Intended Audience This manual is for system managers or network managers who are responsible for making server products available on their Ethernet LANs. A system manager is responsible for the VMS system that is about to be established as a load host. A network manager is the person responsible for the local area network (LAN). To use this manual effectively, you should be familiar with both DECnet Phase IV network management concepts and the VMS operating systeol. vii Structure of This Manual This manual has four chapters and three appendixes: Chapter 1 Provides an overview of the installation and preparation procedures. Chapter 2 Explains how to install the distribution software. Chapter 3 Explains how to configure the load host's node database. Chapter 4 Explains how to verify the installation by first down-line loading the server image and then testing a few server commands. Appendix A Usts the names of the files in the DECserver 300 distribution kit. Appendix B Discusses briefly the remote console facility (RCF). Appendix C Contains examples of the installation and configuration procedures, and examples of verification by down-line loading. Conventions Used in This Manual Familiarizing yourself with the conventions discussed in this section helps you use this manual effectively. The following conventions apply to numbers: • All numbers are decimal unless otherwise noted. • All Ethernet addresses are given in hexadecimal. Graphic Conventions Used in This Manual Convention Meaning This special type indicates system output or user input. System output is in black type; user input is in red type. Special type UPPERCASE viii Uppercase letters in command lines indicate keywords that must be entered. You can enter keywords in either uppercase or lowercase. You can abbreviate command keywords to the smallest number of characters that distinguishes the keyword to the server. Convention Meaning lowercase italics Italics in command syntax or examples indicate variables for which either the user or the system supplies a value. [ ] Square brackets in command syntax statements indicate that the enclosed value(s) are optional. You can enter none or one. Default values apply for unspecified options. (Do not type the brackets.) BOLD In summaries of characteristics, bold type indicates default values. bold In text, words appearing in bold type introduce new terms or concepts and can also be found in the glossary. Press the specified key. For example, IRETI means that you should press the RETURN key. !CTRLlx! Hold down the CONTROL key and then press the key specified by x. The server displays this key combination as AX. ix 1 Installation Overview The software that you are about to install consists of the files in the DEC server 300 distribution kit. First you install the distribution software onto your VMS system, then you configure your systenl node database for all new servers. Next, you verify the installation by down-line loading one test server. Downline loading means sending the server image from the established load host to the server. Finally, you issue a few server cOlnmands to test the server system. NOTE If you have the Terminal Server Manager (TSM) software, an optional network management product available for VMS load hosts, read the documentation for TSM before you install the DECserver 300 software. TSM affects the way you install and manage servers. 1.1 Installation Flow Chart This chapter provides a flow chart of the installation process (see Figure 1-1). Also, there is an overview of installing the distribution software, and an overview of configuring the load host's node database. 1-1 Figure 1-1: Terminal Server Software Installation Flow Chart DETERMINE WHICH SYSTEMS ARE THE LOAD HOSTS Refer to Section 2. 1 CHECK FOR FREE DISK SPACE PLACE DISTRIBUTION MEDIUM ON DEVICE DRIVE INVOKE VMSINST AL AND ANSWER THE VMSINST AL QUESTIONS PRINT IDISPLA Y (recommended) REST ART VMSINST AL (If you stopped to read the release notes) Refer to Section 2.2 INITIATE THE INSTALLATION VERIFICATION PROCEDURE (lVP) (recommended) READ THE MESSAGES AND EXIT VMSINSTAL EDIT SYSTEM START-UP FILE IF NECESSARY LKG-2868-89J Figure 1-1 1-2 DECserver 300 Software Installation (VMS) Figure 1-1 (Cont.): Terminal Server Software Installation Flow Chart INSTALL DISTRIBUTION SOFTWARE ON THE ALTERNATE HOST Refer to Section 2.3 CHECK THAT DECnet PHASE IV IS INSTALLED AND RUNNING CHECK THAT THE DISTRIBUTION SOFTWARE IS INSTALLED IN THE CORRECT DIRECTORY Refer to Section 3. 1 LOCATE SERVER IDENTIFICATION CARD CHECK THAT EACH NEW SERVER DECnet NODE NAME AND NODE ADDRESS ARE UNIQUE INVOKE DSVCONFIG Refer to Section 3.2 CHOOSE YOUR CONFIGURATION OPTION(S) IF APPROPRIATE. VERIFY MERGE ON V AXcluster NODES Refer to Section 3.3 EXIT DSVCONFIG Refer to Section 3.4 VERIFY LOAD HOST INST ALLA TION Refer to Section 4. 1 VERIFY SERVER SYSTEM INST ALLA TION Refer to Section 4.2 LKG-2869-891 Installation OveNiew 1-3 1.2 Installing the Distribution Software You install the server distribution software onto a VMS system with an automated procedure called VMSINSTAL. VMSINSTAL is an interactive procedure that calls and controls the DEC server 300 installation procedure. The DECserver 300 software distribution kit includes a procedure file that VMSINSTAL uses to do the installation. The first page of Figure 1-1 shows the steps of this procedure. When you run VMSINSTAL, the following tasks are performed: • Creates a directory called SYS$SYSROOT:[DECSERVER] on the load host, if necessary • Copies the files from the distribution media into this directory • Optionally prints a copy of the DECsel'vel' 300 Release Notes VMSINSTAL also provides an installation verification procedure (IVP) that can optionally be used to verify that the DEC SERVER directory exists, that all the files from the distribution kit are in the directory, and that the release notes are in the SYS$HELP directory. Chapter 2 contains the procedure to install the distribution software. 1.3 Configuring the Load Host's Node Database Once you copy the distribution software to your VMS system, you should configure the system node database to support new servers. You configure this database with an automated procedure called DSVCONFIG. The second page of Figure 1-1 shows the steps of this procedure. DSVCONFIG also automatically enables the service circuit. The DSVCONFIG configuration procedure file is part of the DECserver 300 software distribution kit. DSVCONFIG uses DECnet commands to carry out the configuration; therefore, DECnet must be running on your VMS system. Configuration of the load host's node database means defining an entry for each server in three places: 1. Data file called DSVCONFIG.DAT The DSVCONFIG.DAT file is the server configuration database. DSVCONFIG.DAT is automatically created by DSVCONFIG and is part of a load host's node database (see Figure 1-2). 1-4 DECserver 300 Software Installation (VMS) 2. DECnet operational (also called "volatile") database 3. DECnet permanent database. Figure 1-2: Load Host Node Database Configuration LOAD HOST NODE OAT ABASE I DECnet OPERA TIONAL DATABASE I I DECnet PERMANENT DATABASE I SERVER CONFIGURA TION DATABASE (DSVCONFIG.DAT) LKG-2870-891 When you complete the configuration procedure, your VMS system is established as a load host for each server that has an entry in the load host's node database. When installing new versions of DECserver products, always check the product release notes for information on the latest DSVCONFIG.COM. Chapter 3 contains the procedure to configure the load host's node database. For more information on DSVCONFIG, see the DECserver 300 Management manual. Installation Overview 1-5 1.4 Verifying the Installation After you configure the load hosts' node databases, you perform two verifications. First, you verify the load host installation by down-line loading the server image. Then, after loading the server, you verify the server system installation. You verify the server system by testing a few server commands at an interactive terminal, which must be connected to the server. Chapter 4 contains the procedures to verify the load host and server system installation. 1.5 Prerequisite and Optional Products The DECserver 300 Software Product Description contains a list of prerequisite and optional products for the DECserver 300 terminal server. 1-6 DECserver 300 Software Installation (VMS) 2 Installing the Distribution Software This chapter provides a step-by-step procedure for installing the DECserver 300 distribution software onto your VMS load host. Install the software using VMSINST AL. COM, which is an automated procedure that is part of the VMS operating system. Figure 1-1 provides an overview of the installation process. VMSINSTAL has the following conventions: • At the end of each question, either a colon (:) or a question mark (7) appears. To answer a question, type your response imll1ediately after the colon or question mark; then press the RETURN key. • After each question, the default response, if there is one, displays in brackets ([ D. To respond to a question with the default answer, press only the RETURN key. • To get help after any question, type a question mark (?). After the help display, the question is repeated. See the VMS doculnentation for a complete description of VMSINSTAL. 2.1 Preparing for Installation Digital Equipment Corporation advises that you establish more than one systeln as a load host for each server. Alternate hosts free the server from dependence on one particular load host. For each server, Digital suggests a minimum of two load hosts. Digital also recommends one load host for every ten servers on a network. 2-1 This procedure requires the VMS operating system, which includes the VMS Required Saveset and Network Support tailoring classes, to be installed on the load host. Perform the following procedure before you install the distribution software on a load host. Step 1: Determine which systems are the load hosts. You must install the distribution software onto all of the systems designated as load hosts. Ask your network manager or the person responsible for assigning load hosts to tell you which are the designated systems. When selecting alternate load hosts, you can choose any Digital system for which a DECserver 300 distribution kit is available. DECserver 300 software distribution kits are available for the VMS and ULTRIX-32 systems. Note that you do not need a separate software license for each load host, but you do need a separate license for each server. Step 2: Back Up the system disk (recommended). At this point, you might wish to back up your system disk. Step 3: Check for free disk space. The DECserver 300 software requires 800 free blocks of disk space on each load host for copying the distribution files; however, the software uses a peak of 1218 blocks during installation. An additional 2048 free blocks of disk space is required for each up-line dump. 2.2 Installing on the Primary Load Host Perform the following procedure to install the distribution software on the primary or first load host. The software installation procedure takes approximately 10 to 15 minutes. If you wish to abort the installation procedure at any time, press 1CTRLIY I. The installation procedure then deletes all files it has created up to that point and returns you to the DCL level. You must invoke VMSINSTAL again to retry the installation procedure. Step 1: Place the distribution medium on the appropriate device drive. 2-2 DECserver 300 Software Installation (VMS) Step 2: Invoke VMSINSTAL. Invoking VMSINSTAL. COM requires the appropriate privileges. Refer to the VMS System Manager's Manual for a list of the necessary privileges. Log in to the system manager account, and enter the following cOlumands: $ SET DEFAULT SYS$UPDATE IRETI $ @VMSINSTAL DS3 device-identifier OPTIONS N IRETI Here, DS3 is the VMS three-letter facility code tor the DECserver 300 product, and device-identifier is the device on which the distribution mediunl is Inounted. OPTIONS N is an optional parameter that indicates you want to be prompted to display or print the DECserver 300 Release Notes. If you do not include the OPTIONS N parameter, VMSINSTAL does not prompt you to display or print the release notes. You are strongly recommended to read the release notes before proceeding with this installation. If you do not want to print the release notes or if you are interested in VMSINSTAL's other options, see the VMS System Manager's Manual, which is part of the VMS docUlnentation set. If you are installing onto alternate load hosts with copied savesets, the VMSINSTAL command line format differs slightly. See the VMS documentation on VMSII'JSTAL. Step 3: Answer the VMSINSTAL questions. VMSINSTAL displays the procedure title and the date and time. It continues with the following (the warning luessage appears only if DECnet is running): %VMSINSTAL-W-DECNET, Your DECnet network is up and running. * Do you want to continue anyway [NO]? 1. Type YES and press the RETURN key to proceed with the installation. VMSINST AL asks: * Are you satisfied with the backup of your system disk [YES]? 2. If backup is satisfactory, press the RETURN key to answer YES. If you answer NO, the installation procedure terminates. Take appro- priate action and start the procedure again. Installing the Distribution Software 2-3 If you are installing from the distribution media rather than from copied savesets, VMSINSTAL prompts you to mount the first volume, which you did at step 1: Please mount the first volume of the set on device-identifier. * Are you ready? 3. Type YES and press the RETURN key. A confirmation message says that the medium is mounted. The procedure continues: The following products will be processed: DS3 Vn.n Beginning installation of DS3 Vn.n at hh:mm %VMSINSTAL-I-RESTORE, Restoring product saveset A ... NOTE DEC server 300 software version numbers are not specified in this manual. For example, the release notes file is shown as DS3n1Ul.RELEASE_NOTES. Here, 111111 represents the version number; if you are installing Version 1.0, the release notes file is DS3010.RELEASE_NOTES. Step 4: Print and/or display the release notes (recommended). Next, the procedure lists your options for printing and displaying the release notes. Release Notes Options: 1. 2. 3. 4. 5. Display Release Notes Print Release Notes Both 1 and 2 Copy release notes to SYS$HELP Do not display, print, or copy release notes * Select option [3]: Select one of these options. Digital recommends that you select option 2. • If you select option 1, you see: VMI$ROOT:[SYSUPD.DS3nnn]DS3nnn.RELEASE_NOTESi1 The release notes immediately start scrolling at your terminal. The release notes might contain up to 30 screens. 2-4 DECserver 300 Software Installation (VMS) • If you select option 2, VMSINST AL asks you which queue you want to send the file to for printing: * Queue name [SYS$PRINT): Press the RETURN key to print the release notes on the default printer, or specify another print queue. A message indicates that the systeln has queued the file. • If you select option 3, VMSINSTAL first asks you which queue you want to send the file to for printing: * Queue name [SYS$PRINT): Press the RETURN key to print the release notes on the default printer, or specify another print queue. A message indicates that the system has queued the file for printing. Next, VMSINSTAL displays the following, then the release notes immediately start scrolling at your ternlinal. VMI$ROOT:[SYSUPD.DS3nnn)DS3nnn.RELEASE_NOTESil After the system queue message and the release notes are displayed (if you selected one of the display options), the procedure continues by asking: * Do you want to continue the installation [N)? If you haven't read the release notes, press the RETURN key to stop the pro- cedure and review the release notes. Check for any changes that can affect this installation. (VMSINSTAL places the release notes file, DS3111111.RELEASE_ NOTES, in the SYS$HELP directory.) Step 5: Restart VMSINSTAL if you stopped to read the release notes. If you discontinued the installation procedure at the end of step 4, then enter this form of the VMSINST AL command to restart the procedure: $ @VMSINSTAL DS3 device-identifier IRETI After typing this command, you must answer the VMSINST AL questions (re- . fer to step 3). Installing the Distribution Software 2-5 Step 6: Initiate the Installation Verification Procedure (IVP) (recommended). After the release notes option menu, the procedure continues: The following products will be processed: DS3 Vn.n Beginning installation of DS3 Vn.n at hh:mm %VMSINSTAL-I-RESTORE, Restoring product saveset A .•. %VMSINSTAL-I-RELMOVED, The product's release notes have been successfully moved to SYS$HELP. * Do you want to run the IVP after the installation [YES]? The installation verification procedure (IVP) verifies that the DEC SERVER directory exists, that all the files from the distribution kit are in the directory, and that the release notes are in the SYS$HELP directory. Digital recomlnends that you press the RETURN key to initiate the IVP. Step 7: Read the messages and exit VMSINSTAL. If you are on a VAXc1uster node, the following message displays: If you intend to execute this layered product on other nodes in your VAXcluster, and you have the appropriate software license, you must prepare the system-specific roots on the other nodes by issuing the following command on each node (using a suitably privileged account): $ CREATE/DIRECTORY SYS$SPECIFIC:[DECSERVER]/PROTECTION=(S:RWED,O:RWED) VMSINSTAL continues, as follows, for both single and VAXc1uster nodes: %VMSINSTAL-I-RESTORE, Restoring product saveset B .•. Your installation is now complete. After exiting from VMSINSTAL: 1. Edit your system start-up file so that it defines the logical MOM$LOAD as a search string with a value equal to the current search string plus the added element SYS$SYSROOT:[DECSERVERJ. For example: DEFINE/SYSTEM/EXEC/NAME_ATTRIBUTE=NO_ALIAS/NOLOG MOM$LOAD 'current-search-string',SYS$SYSROOT:[DECSERVERJ If the current search string associated with MOM$LOAD in your start-up file is SYS$SYSROOT:[DECSERVER] or if you have already made this change for a previous installation, there is no need to edit this file. This command ensures that the location of the server image is defined each time the system is rebooted, necessary for successful down-line loading. 2-6 DECserver 300 Software Installation (VMS) 2. Configure the server into your host's database. Execute a command procedure called DSVCONFIG.COM. This command procedure is in the SYS$SYSROOT:[DECSERVERj directory. If you have already executed this procedure from previous installations, you need to configure only any additional units. All previously defined units will still be configured. 3. The Installation Verification Procedure (IVP) for the DECserver 300 can be found in SYS$TEST and may be run at any time by executing the command procedure DS3$IVP.COM. You have finished the first part of the installation. The procedure continues as follows: NOTE If you are installing files onto a VAXcluster node, the messages indicate that the files are copied to the SYS$COMMON:[DECSERVER] directory, instead of SYS$SYSROOT:[DECSERVER). %VMSINSTAL-I-MOVEFILES, Files will now be moved to their target directories ... Beginning installation verification procedure for DECserver 300 Vn.n. Successfully located SYS$SYSROOT:[DECSERVERj directory Successfully located SYS$SYSROOT:[SYSHLPjDS3010.RELEASE_NOTES Successfully located SYS$SYSROOT:[DECSERVERjSH1601ENG.SYS Successfully located SYS$SYSROOT:[DECSERVERjDSVCONFIG.COM Successfully located SYS$SYSROOT:[DECSERVERjDSVCONFIG.DAT Successfully located SYS$SYSROOT:[DECSERVERjDS3_010_DEFAULTS.COM Successfully located SYS$SYSROOT:[DECSERVERjTSM$DS3_nnn_ADD_LOCAL_SERVICE.COM Successfully located SYS$SYSROOT:[DECSERVERjTSM$DS3_nnn_DEDIC_SERV_PRINTER.COM Successfully located SYS$SYSROOT:[DECSERVERjTSM$DS3_nnn_DEDIC_SERV_TERM.COM Successfully located SYS$SYSROOT:[DECSERVERjTSM$DS3_nnn_DSR_DTR_TERM.COM Successfully located SYS$SYSROOT:[DECSERVERjTSM$DS3_nnn_GET_CHAR.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_nnn_HOST_INIT_PRINTER.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_nnn_PC_TERM_OR_SERV.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_nnn_PORT_DEFAULT.COM Installation verification procedure for DECserver 300 Vn.n successful Installation of DS3 Vn.n completed at hh:mm NOTE The Terminal Server Manager (TSM) files are used only if you have the Terminal Server Manager software. The procedure concludes: VMSINSTAL procedure done at hh:mm Installing the Distribution Software 2-7 Proceed to step 8 if you need to edit your system start-up file. If you do not need to edit your system start-up file, you can either proceed to Section 2.3 to install the distribution software onto an alternate load host, or to Section 2.4 to finish the VMSINSTAL installation procedure. Step 8: Edit your system start-up file, if necessary. MOM$LOAD is a logical name that your load host uses to find the image file of any product that must be down-line loaded. For each product, MOM$LOAD has an associated equivalence string that specifies the location of the product' s image file. Thus, the following command equates the logical natne MOM$LOAD to the location of your DECserver 300 image file: ~/DEFINE/SYSTEM/EXEC/NAME_ATTRIBUTE=NO_ALIAS/NOLOG MOM$LOAD - SY$$SYSROOT:[DECSERVER] If your system is a load host for several products, then the location of each image file must be defined by a list of equivalent strings. For example, the following command defines the location of other Ethernet product image files as well ~s the DECserver 300 image file: DEFINE/SYSTEM/EXEC/NAME_ATTRIBUTE=NO_ALIAS/NOLOG MOM$LOAD SYS$SYSROOT: [MOM$SYSTEM],SYS$SYSROOT: [DECSERVER] Two or more equivalence strings make up a search list. When your VMS systeln is requested to down-line load a product, it looks through the search list until it finds the location of the product's image file. Your host cannot down-line load the DECserver 300 itnage file unless the search list defined for MOM$LOAD has the correct location of the image file. To see what the current search string is for MOM$LOAD, use the DCL SHOW LOGICAL command: u{Y\on,:tl.or.:-IO'1 :. "rt\on-t.ss'{s-n:M: {u,lni5YST6t1_IV I, $ SHOW LOGICAL MOM$LOAD IRETI~\(y)oYY\S5'15Tf.M·' ~ "5y51>S'{5'eoo-r:LNll)'fV\A'':;:;yS~em:111 (\....NM4 \:~fi·- T~ If SYS$SYSROOT:[DECSERVER] is defined for MOM$LOAD, you do not have to define MOM$LOAD. Define MOM$LOAD only if: • No equivalence string exists for MOM$LOAD (the SHOW LOGICAL command results with the message "N 0 translation for logical name MOM$LOAD") or • 2-8 The equivalence strings defined for MOM$LOAD do not include SYS$SYSROOT:[DECSERVER). DECserver 300 Software Installation (VMS) If MOM$LOAD is already defined for other products but not for the DECserver 300 product, you must define MOM$LOAD by specifying SYS$SYSROOT:[DECSERVER] along with the current search string(s), as shown in the VMSINSTAL example. If you specify only SYS$SYSROOT:[DECSERVER] for MOM$LOAD excluding the current search string(s), then SYS$SYSROOT:[DECSERVER] will replace the current search string(s). Your VMS system will not be able to load the image files located by the current search string(s). Proceed to Section 2.3 to install the distribution software onto an alternate load host, or proceed to Section 2.4 to finish the VMSINSTAL installation procedure. 2.3 Installing onto Alternate Load Hosts Digital recommends that you establish alternate load hosts for each server. Alternates free the server frOIn dependence on one load host because an alternate load host can perform a down-line load if the original load host is unavailable. In addition, alternate load hosts can receive up-line dunlps fronl servers. Regarding the assignment of load hosts, Digital suggests both the following: • At least one other load host as a backup to the original for each server • At least one load host for every ten servers As with the original load host, an alternate VMS load host must: • Be running DECnet Phase IV • Have an Ethernet controller on the same Ethernet as the server • Have the distribution software installed • Have DECserver 300 entries in its server configuration database DSVCONFIG.DAT, the DECnet operational database, and the DECnet permanent database Installing the Distribution Software 2-9 2.3.1 Installing onto Single Systems To install the server distribution software onto an alternate VMS load host that is not a member of a VAXcluster, use one of these two methods: • Place your distribution media on the appropriate device of the new load host, and repeat the installation procedure detailed in Section 2.2. • Follow this procedure: 1. Type the following command on the original load host: $ @VMSINSTAL DS3 device-identifier OPTIONS G SYS$UPDATE: IRETI In this case, option G gets the savesets and stores them in the SYS$UPDATE directory. 2. Copy the savesets from the original load host to the alternate load host's SYS$UPDATE directory. The savesets are DS3111111.A and DS3111111.B. Here, 111111 equals the version number of the DECserver 300 software (e.g., 111111 equals 010 for V1.0). 3. Run VMSINSTAL on the alternate load host. $ @VMSINSTAL DS3 SYS$UPDATE: IRETI 2.3.2 Installing onto Other Operating Systems To install the DEC server 300 distribution software onto an operating systen1 other than VMS, follow the instructions in the DECserver 300 Software Il1stallatiol1 manual for that system. The appropriate installation n1anual is included with the documentation kit that comes with the software distribution kit for that operating system. 2.4 After Exiting VMSINSTAL After you exit VMSINST AL, follow these steps: 2-10 1. Check the DECserver 300 Release Notes to see if you have to install any additional software from the distribution media. If so, install those distribution files. 2. Give the DECserver 300 Release Notes to the server manager. 3. Go to Chapter 3 to configure the load host's node database. DECserver 300 Software Installation (VMS) 3 Configuring the Load Host's Node Database This chapter provides a step-by-step procedure for configuring a VMS load host's node database for new servers with an automated procedure called DSVCONFIG. Configuring this database is part of the software installation. After this procedure, your VMS system is established as a valid load host for the new servers. Figure 1-1 provides an overview of the installation process. If you ran the installation procedure described in Chapter 2, DSVCONFIG.COM is now in the SYS$SYSROOT:[DECSERVER] directory for single systems and in SYS$COMMON:[DECSERVER] for VAXc1uster members. The load host creates and maintains all server-related files in this directory. NOTE DSVCONFIG.COM accommodates such products as the DECserver 100, DECserver 200, DECserver 300, and DECserver 500. However, some previous releases of DSVCONFIG.COM do not accommodate all the DECserver products. Therefore, use the command file on this kit for all configurations. DSVCONFIG has the following conventions and requirements: • To select an option, type a J1lenu number and press the RETURN key. • To answer a question, type your response itnmediately after the colon or question mark, and press the RETURN key. 3-1 • After each question, the default response, if there is one, displays in brackets ([ D. To respond to a question with the default answer, press only the RETURN key. • To get help after any question, type a question mark (?). After the help display, the question is repeated. • To exit an option without making any changes, type I CTRUzl. You are returned to the DSVCONFIG Menu. • To exit DSVCONFIG at the menu level, type I CTRuzl. You are returned to the DCL prompt. • When you finish an option, DSVCONFIG automatically returns you to the DSVCONFIG Menu. See the DECserver 300 Management manual for a complete description of DSVCONFIG. 3.1 Preparing for Configuration Perform the following to prepare for configuring the load host's node database: Step 1: Check that DECnet Phase IV is installed and running. For infornlation about DECnet Phase IV, see the VMS DECnet-VAX System Managei"s Guide. Step 2: Check that all distribution software was installed in these directories: • SYS$SYSROOT:[DECSERVER] for single systems • SYS$COMMON: [DEC SERVER] for VAXc1usters See Appendix A for a list of the distribution files. Step 3: Locate the server Identification Card. Ask the hardware installer for the DECserver 300 Identification Card for each new DECserver 300 terminal server. The network manager and the hardware installer recorded the server's DECnet node nalne and node address as well as the Ethernet address on this card. You need to know this information to answer prompts during DSVCONFIG. 3-2 DECserver 300 Software Installation (VMS) If your DECnet network is divided into areas, each DECnet node address takes the form aa.11111111. Here, aa is a decimal area number frOln 2 to 63, 11111111 is the node address, and the period distinguishes area from address. For example, 17.1003 is a valid node address. Each DECnet node name must have from 1 to 6 alphanumeric characters with at least one character being an alphabetic character. For example, DSV5 and LION77 are valid DECnet node names. Each DECserver 300 terminal server is delivered with a unique Ethernet hardware address. This address is six pairs of hexadecimal digits with a hyphen (-) separating each pair. For example, 08-00-01-00-AB-CD is an address with a valid format. The Ethernet address is on the control/indicator panel of the DECserver 300 terminal server. 3.2 Configuring on the Load Host Perform the following procedure to configure the load host's node database. The load host can be a single system or a VAXc1uster node. CAUTION Do not execute any DECnet commands that are a part of DSVCONFIG separate from the following DSVCONFIG procedure; otherwise, DECnet databases could be changed without changing DSVCONFIG.DAT, causing a synchronization problem. Step 1: Check that each new server DECnet node name and node address are unique. Check the uniqueness of the server's DECnet node address and node name by specifying the address or name with the NCP SHOW NODE command: $ MCR NCP !RET! NCP>SHOW NODE node-name CHARACTERISTICS !RET! or NCP>SHOW NODE node-number CHARACTERISTICS !RET! If NCP shows a node already defined, see the network manager to resolve the conflict in names. Configuring the Load Host's Node Database 3-3 Step 2: Invoke DSVCONFIG. To invoke DSVCONFIG.COM, you need OPER and SYSPRV privileges. Log in to the system account or any account with OPER and SYSPRV privileges, and enter the following cOlnmands: $ SET DEFAULT MOM$LOAD: $ @DSVCONFIG IRETI IRETI NOTE The former command assumes you have defined MOM$LOAD to locate the DECserver 300 software image in SYS$SYSROOT:[DECSERVER] (see Section 2.2). DSVCONFIG starts with these actions: • It determines whether the DECnet key is installed. If DECnet is miss- ing, DSVCONFIG prints a message and exits. You must have DECnet to run this procedure because DSVCONFIG executes DECnet commands. • It checks the existence and format of a data file called DSVCONFIG.DAT. It finds one of three possible situations and continues accordingly: The DSVCONFIG.DAT file does not exist in SYS$SYSROOT:[DECSERVER]. The procedure creates DSVCONFIG.DAT and displays a message telling you that the file was not found and a new one was created. SYS$SYSROOT:[DECSERVER] already has this file formatted correctly. This is the case if DSVCONFIG was previously used to add DECserver 300 entries. The procedure continues with its next task. SYS$SYSROOT:[DECSERVER] or for VAXclusters, SYS$SPECIFIC:[DECSERVER] already has this file, but not in the correct fonnat. The procedure reformats the file. For VAXclusters, SYS$SPECIFIC:[DECSERVER] on each VAXcluster node might have an older version of the DSVCONFIG.DAT file. In this case, the DSVCONFIG procedure copies the server entries from that data file into the DSVCONFIG.DAT file on the SYS$COMMON:[DECSERVER], a directory shared by the VAXcluster nodes. The procedure renames the DSVCONFIG.DAT file in SYS$SPECIFIC so that the DSVCONFIG.DAT file in SYS$COMMON is used thereafter. 3-4 DECserver 300 Software Installation (VMS) Refer to Section 3.3 for further information. • It informs you that each DECserver terminal server must have a unique DECnet node name and DECnet node address. • It asks you to either continue or to exit: Press <RET> to start, or <CTRL/z> to exit ... Press the RETURN key to see the DSVCONFIG options menu. Step 3: Choose your configuration option(s). DSVCONFIG displays: DECserver Configuration Procedure Version: Vn.n 1 2 3 4 5 CTRL/z - Menu of Options List known DECservers Add a DECserver Swap an existing DECserver Delete an existing DECserver Restore existing DECservers Exit from this procedure Your selection? Type the number of the option you want. Then press the RETURN key. Section 3.2.1 contains the procedure for option I, list known DECservers. Section 3.2.2 contains the procedure for option 2, add a DECserver. Appendix C contains examples of each option. Configuring the Load Host's Node Database 3-5 3.2.1 List Known DECservers (Option 1) Select option 1 to list the DECserver terminal servers in the DSVCONFIG.DAT data file. Type the number one and press the RETURN key. The contents of the DSVCONFIG.DAT file are listed in seven columns. Option 1 displays a listing such as this: DECnet DECnet Server Service Type Address Name Circuit Ethernet Address ------28.900 BUNNY DS200 DS300 28.1001 BACH 28.1002 BEETHO DS300 28.1003 MOZART DS100 28.1005 HAYDN DS300 28.1019 OCELOT DS500 28.1022 JAGUAR DS500 28.1023 BEATLE DS100 Load File Dump File ------- ----------------- ------------- ------------- BNA-O UNA-O UNA-O UNA-O UNA-1 UNA-O UNA-O UNA-O 08-00-2B-02-FO-99 PR0801ENG.SYS DS2BUNNY.DMP 08-00-2B-02-24-CC SH1601ENG.SYS DS3BACH.DMP 08-00-2B-03-AA-2B SH1601ENG.SYS DS3BEETHO.DMP 08-00-2B-02-24-DD PS0801ENG.SYS PSDMP24DD.SYS 08-00-2B-03-AA-F1 SH1601ENG.SYS DS3HAYDN.DMP 08-00-2B-03-EE-FF DS50CELOT.SYS DS50CELOT.SYS 08-00-2B-03-E1-F1 DS5JAGUAR.SYS DS5JAGUAR.SYS 08-00-2B-02-24-2D PS0801ENG.SYS PSDMP242D.SYS Total of 8 DECservers defined. (Press RETURN for menu) 3.2.2 Add a DECserver (Option 2) Select option 2 to add an entry for a new server in the server configuration database DSVCONFIG.DAT, the DECnet operational database, and the DECnet permanent database. You will need the DECserver 300 Identification Card. To add a server, follow these steps: 1. Type 2 and press the RETURN key. DSVCONFIG asks: DECserver type? 2. Type DS300 and press the RETURN key. DSVCONFIG asks: DEC net node name for unit? 3. Specify the DECnet node name for the new server. DSVCONFIG asks: DECnet node address for unit? 3-6 DECserver 300 Software Installation (VMS) 4. Specify the DECnet node address for the new server. If you specify a node address that is already defined in DSVCONFIG.DAT, you get a DSVCONFIG error, nothing is added, and the Add option is terminated. DSVCONFIG asks: Ethernet address of unit? 5. Specify the Ethernet address of the new server. DSVCONFIG asks: DECnet Service Circuit-ID [default-id]? 6. Press the RETURN key if the default ID is the load host's service circuit. If not, specify the service circuit-ID of the load host's Ethernet controller as follows: UNA-n for DEUNA or DELUA QNA-n for DELQA, DEQNA, or DESQA BNA-n for DEBNA SVA-n for DESVA Here, n is an integer (typically 0 or 1). DSVCONFIG adds the entry for the new server to the databases and sets SERVICE ENABLED on the specified service circuit, both of which are necessary for down-line loading. If the selvice circuit becOInes disabled, Appendix C contains the commands to enable the service circuit. At the end of the Add option, you might get network control program (NCP) messages (information, confirmations, and errors). In the case of error nlessages, the operation might not have been successful. For the explanations of these messages, see the VMS System, Messages and Recovery Procedures Reference Manual. Configuring the Load Host's Node Database 3-7 CAUTION If you get an error from DECnet while you are adding a server, the entry is added to the DSVCONFIG.DAT file even though it is not entered in the DECnet databases. To correct this synchronization problem, follow these steps: 1. Use option 4 to delete the entry. (See the example in Appendix C, or refer to the DECseI'Ver 300 Management manual.) 2. Fix the condition causing the DECnet error. 3. Return to option 2 to add the server again with the correct information. 3.2.3 Options 3, 4, and 5 Options 3, 4, and 5 are not normally used during the installation procedure. Refer to the DECserver 300 Management manual for a description of these options. 3.3 Verifying a Merge on VAXcluster Nodes The DSVCONFIG procedure looks at each entry in SYS$SPECIFIC and determines if that entry is already in SYS$COMMON. If the entry is in SYS$COMMON, it is not merged. If the entry is not in SYS$COMMON, it is merged. In the case of a merge, DSVCONFIG renames the old DSVCONFIG.DAT file on the SYS$SPECIFIC directory to DSVCONFIG_SPECIFIC.DAT. As a result, you still have the original entries in case you need to repeat the merge. The following DSVCONFIG messages appear if a merge occurs: Merging SYS$SPECIFIC:[DECSERVER]DSVCONFIG into SYS$COMMON:[DECSERVER]DSVCONFIG 8 servers were defined in SYS$SPECIFIC:[DECSERVER]DSVCONFIG.DAT 3 servers were already in SYS$COMMON:[DECSERVER]DSVCONFIG.DAT 5 servers merged into SYS$COMMON:[DECSERVER]DSVCONFIG.DAT You must assign a unique DECnet node address for each new DECserver unit. name and DECnet node Press <RET> to start, or <CTRL/Z> to exit •.. 3-8 DECserver 300 Software Installation (VMS) If a merge occurs, follow this procedure to ensure that DSVCONFIG updates the DSVCONFIG.DAT file correctly and places it in the SYS$COMMON directory: 1. Select the List option to verify that the merge was successful. The List option should display the correct service circuit-IDs at each node. Informational messages display the status of the merge as it progresses. 2. Verify that the service circuit-ID is correct. Since the individual nodes have the correct service circuit ID for each server entry, the correct IDs are merged into the new file. If the service circuit IDs are not correct for a particular node, you can correct thenl in one of two ways: • You can run DSVCONFIG SET_CIRCUIT at that node (for VAXclusters, this method is better). The following shows an example of the command you would use: $ @DSVCONFIG SET_CIRCUIT UNA-O • You can run DSVCONFIG at the node with the errors and use the Swap option to change the service circuit-IDs. 3.4 Exiting DSVCONFIG When you exit DSVCONFIG: 1. Give the server manager the DEeserver 300 Ide11tification Card for each server that you defined. 2. Ask the selver manager to store the card in the notebook with the documentation set for the DECselver 300 software. 3. Proceed to Chapter 4 to verify the load host and server system installation. Configuring the Load Host's Node Database 3-9 4 Verifying the Installation To complete the software installation, you need to perform two verifications. First, you verify the load host installation by down-line loading the server image. Then, after loading the server, you verify the server systenl installation. Here, system installation means the installation of the complete seIVer system-the hardware with the correct software loaded and running. You verify the server system by testing a few server commands at an interactive terminal, which must be connected to the server. 4.1 Verifying the Load Host Installation To verify the installation of the load host, use it to down-line load the server image to one DECserver 300 terminal server; then read the DECnet eventlogging messages. The messages confirm that the new load host: • Has the appropriate files in the correct directory • Has a correct entry in its node database for the server • Can successfully down-line load the server image to the server The DECserver 300 down-line loading procedure does not let you specify which load host loads a server. The server sends a DECnet message requesting a down-line load to all load hosts. The first load host to "volunteer" is the host that does the loading. Make sure that the verification server is configured only on load hosts that have the latest server software. If the verification server remains configured on any host with an older version of the server software, that load host might be the node that down-line loads the server. 4-1 To find out if a load host has the target server listed, execute the LIST option of the DSVCONFIG (see Section 3.2.1). The server image is down-loaded to the server when you initialize the server. You initialize the server by powering up the hardware unit or with the server INITIALIZE command. The DEeserver 300 Management manual has details about initializing the server. 4.2 Verifying the Server System Installation To verify the total server system installation, test a few server commands at an interactive terminal connected to a server port. This step confirms that: • The correct version of the software is in the server. • The server hardware operates with the new software. • The new software is running successfully. Follow this sequence: 1. Press the RETURN key two or more times. The following message and prompt should appear. IRETI IRETI DECserver 300 Terminal Server Vn.n (BLnn) - LAT V5.1 Pleass type HELP if you need assistance /Enter username> 2. Read the identification message to ensure that the correct version (Vl1.n) of the. server image was down-line loaded. If you fail to receive this display, the problem could be: • With the load host • With the terminal • That the incorrect software was down-line loaded 3. Enter your user name (any string of 1 through 16 characters that identifies you) and press the RETURN key. The port should now enter local mode, where the local prompt (Local» appears: Enter username> SWINSTALLER IRETI Local> 4-2 DECserver 300 Software Installation (VMS) 4. Use the following server command to see which load host down-line loaded the server software: Local> SHOW SERVER STATUS IRETI The Load Address field in the display tells you which host loaded the server. If that load host does not have the current server software, either install the current server software on the host, or delete the verification server from its load host node database. See Chapter 2 for installing the software, or Appendix C for deleting a server from the node database. 5. Use the TEST PORT command, which verifies whether the terminal is receiving valid character data. On the command line, specify the number of lines and the number of columns you would like displayed. For example, this command displays 5 lines of 80 characters each: Local> TEST PORT COUNT 5 WIDTH 80 IRETI Note that you can interrupt this test by pressing any key. Appendix C shows an example of a TEST PORT display. 6. Issue the SHOW PORT command to display the characteristics of your port and their values: Local> SHOW PORT IRETI A port-characteristics display should appear. Appendix C shows an example of a port-characteristics display. 7. Use the SHOW SERVICES command to show what services are available to you. The following server command produces a list of services and service announcements: Local> SHOW SERVICES IRETI Every terminal and service node in a LAT network is a member of one or more groups, which are specified by a list of numbers from 0 to 255. A terminal user is only aware of the services that are offered by the nodes in the same group as the user's terminal. The DECserver 300 defaults to Group O. When you use the SHOW SERVICES command, it must be a service that recognizes Group O. The server manger can change the group setting of the DECserver 300 terminal server. Appendix C shows an example of a SHOW SERVICES display. Verifying the Installation 4-3 8. Select an available service that you are authorized to use. Use the CONNECT command to verify that the server can logically connect your terminal to that service. On the command line, specify the service name to which you want to connect. The following example connects your terminal to a VMS system offering the LAT service named SYSTEM: Local> CONNECT SYSTEM IRETI When the server successfully connects your terminal to the service you specified, you no longer see the local prompt; rather, you are communicating with the service, in this example, your own VMS system. 9. Enter several commands to verify the ability of the server to exchange data with the service. For example, in this case, you could enter LOGIN, SHOW TIME, and SHOW USERS. 10. Press the BREAK key or log out from the service to return to local mode. Note that pressing the BREAK key does not end the service session you started. 11. Log out the terminal from the server: Local> LOGOUT IRETI If the server system verification encounters any problem, see the server man- ager. If you complete the above steps successfully, the test server is operating cor- rectly, and you can report the successful load host installation and server system installation to the server manager. If this installation is a software upgrade, either you or the server manager must now reload all existing servers. 4-4 DECserver 300 Software Installation (VMS) A DECserver 300 Distribution Files These are the DECserver 300 distribution files: File name Description KITINSTAL.COM Command file that VMSINSTAL uses to do part of the installation procedure. This file is temporary; it is not left on the system after the installation is done. DS3$IVP .COM Installation verification procedure. DSVCONFIG.COM Configuration procedure. DSVCONFIG.DAT Data file used by DSVCONFIG.COM. DS3_nnn_DEFAULTS.COM File used by the Terminal Server Manager (TSM) software. DS3nnn.RELEASE_NOTES Release notes. (nnn=version number) SH1601ENG. SYS DECserver 300 software image. TSM$DS3_nnn_ADD _LOCAL_SERVICE. COM File used by the TSM software. TSM$DS3_nnn_DEDIC_SERV_PRINTER.COM File used by the TSM software. TSM$DS3_nnn_DEDIC_SERV_TERM.COM File used by the TSM software. TSM$DS3_nnn_DSR_DTR_TERM. COM File used by the TSM software. A-1 A-2 File name Description TSM$DS3_nnn_ GET_CHAR. COM File used by the TSM software. TSM$DS3_nnn_HOST_INIT_PRINTER. COM File used by the TSM software. TSM$DS3_nnn_PC_TERM_OR_SERV.COM File used by the TSM software. TSM$DS3_nnn_PORT _DEFAULT. COM File used by the TSM software. DECserver 300 Software Installation (VMS) B Using the Remote Console Facility The DECserver 300 terminal server supports the VMS RelTIote Console Facility (RCF). This appendix explains how to use RCF from a VMS host. If you issue the BROADCAST command yourself to warn users of an upcoming down-line load, you may want to use RCF. To connect to the server with ReF, use the CONNECT NODE command. On the command line, specify either the DECnet node name or DECnet node address of the server. This example shows a connection to the server named BEETHO: $ MCR NCP IRETI IRETI NCP> CONNECT NODE BEETHO Console connected (press CTRL/D when finished) or NCP> CONNECT NODE 28.1002 SERVICE PASSWORD OF23 Console connected (press CTRL/D when finished) IRETI Press the RETURN key to start the log-in sequence for the remote console. Log-in password protection is enabled for the the DECserver 300 remote console port. Therefore, you must supply the log-in password when the server prompts you with a pound sign (#), as shown below (an audible beep signal accompanies the pronlpt). The default password is ACCESS. # The prompt indicates that the link to the server has been made. After you enter the correct password, you can begin using DECserver 300 commands. 8-1 You can also use the CONNECT command with the server's Ethernet address. The following example shows a connection from a VMS system with the service circuit-ID UNA-O to a server with the Ethernet address 08-00-2B04-AA-2B: NCP> CONNECT VIA UNA-O PHYSICAL ADD 08-00-2B-04-AA-2B IRETI You may have to specify the service password with the CONNECT command if a maintenance password is specified on the server. To do so, include the SERVICE PASSWORD keywords on your command line and specify the password. To exit from RCF, type 1CTRLID I: Local> I CTRLlO I To exit from NCP, type EXIT: NCP> EXIT IRETI $ NOTE If you log out from the server with a LOGOUT command, the port is logged out but the remote console session remains active. Type 1CTRLlD 1 to exit the remote console session. The service node prompt reappears, and control passes back to NCP on your VMS system. See the DEeserver 300 Management manual for detailed information on RCF. 8-2 DECserver 300 Software Installation (VMS) C Examples: Installation, Configuration, Verification This appendix shows examples of the installation and the configuration procedures. It also shows the verification of a load host installation by down-line loading and reading DECnet event-logging messages. Finally, Appendix C shows the verification of a server system installation by testing server commands. C.1 Example of an Installation The following example shows a successful installation procedure onto a VMS VS.O system. This example also shows the procedure as Digital Equipment Corporation suggests you run it: 1. Use the option that prints the release notes. 2. Print the release notes. 3. Stop the procedure to read them. 4. Rerun the procedure. C-1 $ SET DEFAULT SYS$UPDATE IRETI $ @VMSINSTAL DS3 MTA2 OPTIONS N IRETI VAX/VMS Software Product Installation Procedure V5.0 It is 17-JUN-1989 at 14:08. Enter a question mark (?) at any time for help. %VMSINSTAL-W-DECNET, Your DECnet network is up and running. * Do you want to continue anyway [NO]? Y * Are you satisfied with the backup of your system disk [YES]? Please mount the first volume of the set on MTA2:. * Are you ready? Y %MOUNT-I-MOUNTED, DS3 mounted on _MTA2: IRETI IRETI IRETI The following products will be processed: DS3 V1.0 Beginning installation of DS3 V1.0 at 14:08 %VMSINSTAL-I-RESTORE, Restoring product saveset A .•. Release Notes Options: 1. 2. 3. 4. 5. Display Release Notes Print Release Notes Both 1 and 2 Copy release notes to SYS$HELP Do not display, print, or copy release notes * Select option [3]: 2 IRETI * Queue name [SYS$PRINT]: IRETI Job DS3010.RELEASE_NOTES (queue SYS$PRINT, entry 314) started on SYS$PRINT * Do you want to continue the installation [N]? IRETI VMSINSTAL procedure done at 14:09 $ C-2 DECserver 300 Software Installation (VMS) Read the release notes. Run VMSINSTAL again: $ @VMSINSTAL DS3 MTA2 IRETI VAX/VMS Software Product Installation Procedure V5.0 It is 17-JUN-1989 at 14:25. Enter a question mark (?) at any time for help. %VMSINSTAL-W-DECNET, Your DECnet network ~ and running. * Do you want to continue anyway [NO]? Y ~ * Are you satisfied with the backup of your system disk [YES]? Please mount the first volume of the set on MTA2:. * Are you ready? Y %MOUNT-I-MOUNTED, DS3 mounted on MTA2: IRETI IRETI The following products will be processed: DS3 Vl.0 Beginning installation of DS3 Vl.0 at 14:25 %VMSINSTAL-I-RESTORE, Restoring product saveset A .•. %VMSINSTAL-I-RELMOVED, The product's release notes have been successfully moved to SYS$HF.LP. * Do you want to run the IVP after the installation [YES]? %VMSINSTAL-I-RESTORE, Restoring product saveset B ..• IRETI Your installation is now complete. 1. After exiting from VMSINSTAL: Edit your system start-up file so that it defines the logical MOM$LOAD as a search string with a value equal to the current search string, plus the added element SYS$SYSROOT:[DECSERVER]. For example: DEFINE/SYSTEM!EXEC!NAME_ATTRIBUTE=NO_ALIAS!NOLOG MOM$LOAD 'current-search-string',SYS$SYSROOT:[DECSERVER] If the current search string associated with MOM$LOAD in your start-up file is SYS$SYSROOT:[DECSERVER] or if you have already made this change for a previous installation, there is no need to edit this file. This command ensures that the location of the server image is defined each time the system is rebooted, necessary for successful down-line loading. 2. Configure the server into your host's database. Execute a command procedure called DSVCONFIG.COM. This command procedure is in the SYS$SYSROOT:[DECSERVER] directory. If you have already executed this procedure from previous installations, you need to configure only any additional units. All previously defined units will still be configured. 3. The Installation Verification Procedure (IVP) for the DECserver 300 can be found in SYS$TEST and may be run at any time by executing the command procedure DS3$IVP.COM. Examples: Installation, Configuration, Verification C-3 %VMSINSTAL-I-MOVEFILES, Files will now be moved to their target directories ... Beginning installation verification procedure for DECserver 300 VI.O Successfully located SYS$SYSROOT:[DECSERVER] directory Successfully located SYS$SYSROOT:[SYSHLP]DS3010.RELEASE_NOTES Successfully located SYS$SYSROOT:[DECSERVER]SH160IENG.SYS Successfully located SYS$SYSROOT:[DECSERVER]DSVCONFIG.COM Successfully located SYS$SYSROOT:[DECSERVER]DSVCONFIG.DAT Successfully located SYS$SYSROOT:[DECSERVER]DS3_010_DEFAULTS.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_ADD_LOCAL_SERVICE.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vIO_DEDIC_SERV_PRINTER.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_DEDIC_SERV_TERM.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_DSR_DTR_TERM.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_GET_CHAR.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_HOST_INIT_PRINTER.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_PC_TERM_OR_SERV.COM Successfully located SYS$SYSROOT:[DECSERVER]TSM$DS3_vl0_PORT_DEFAULT.COM Installation verification procedure for DECserver 300 vl.O successful Installation of DS3 Vl.0 completed at 14:28 VMSINSTAL procedure done at 14:28 $ NOTE The Terminal Server Manager (TSM) files are used only if you have the Terminal Server Manager software. C.2 Example of a Configuration This section gives examples of the following: C-4 • starting DSVCONFIG • listing known terminal servers (option 1) • adding a terminal server (option 2) • swapping an old terminal server for a new terminal server (option 3) • deleting a terminal server from the database (option 4) • restoring existing terminal servers to the database (option 5) DECseNer 300 Software Installation (VMS) C.2.1 Starting DSVCONFIG.COM The following example shows the beginning of the configuration procedure. This example assumes that the latest version of DSYCONFIG has already been run so that the DSYCONFIG.DAT file exists in the correct format. (See Chapter 3 for the prompts that are displayed if the procedure has to either create DSYCONFIG.DAT or reformat it.) $ SET DEFAULT MOM$LOAD $ @DSVCONFIG IRETI IRETI You must assign a unique DECnet node name and DEC net node address for each DECserver you are going to configure. Press <RET> to start, or <CTRL/Z> to exit •.. IRETI DECserver Configuration Procedure version: Vl.8 1 2 3 4 5 CTRL/Z - Menu of Options List known DECservers Add a DECserver Swap an existing DECserver Delete an existing DECserver Restore existing DECservers Exit from this procedure Your selection? C.2.2 Listing Known DECservers (Option 1) This section and the following ones show how the configuration procedure continues for each option. Each option ends by automatically returning you to the menu. Your selection? 1 IRETI DECnet DECnet Server Service Address Name Type Circuit Ethernet Address Load File ------- ----------------- -------------------28.1001 BACH DS300 UNA-O 08-00-2B-02-24-CC SH1601ENG.SYS 28.1003 MOZART DS100 UNA-O 08-00-2B-02-24-DD PS0801ENG.SYS 28.1005 HAYDN DS200 UNA-1 08-00-2B-03-AA-Fl PR0801ENG.SYS Dump File ------------DS3BACH.DMP PSDMP24DD.SYS DS2HAYDN.DMP Total of 3 DECservers defined. Examples: Installation, Configuration, Verification C-5 C.2.3 Adding a OECserver (Option 2) This example adds a new DECserver 300 terminal server named BEETHO. Your selection? 2 !RETI Type a ? at any time for help on a question. Type CTRL/Z for any question to return to the menu without adding the unit. IRETI DECserver type? DS300 DECnet node name for unit? BEETHO IRETI IRETI DECnet node address for unit? 28.1002 Ethernet address of unit? 08-00-2B-03-AA-2B DECnet Service Circuit-ID? [UNA-OJ IRETI IRETI If you get an error message now, the new unit won't be added, and you should delete it from the directory. If you use the List option to get a listing of servers, you see that BEETHO appears on the listing of entries. C.2.4 Swapping an Old Terminal Server for a New Terminal Server (Option 3) In this example, an existing DECserver 100 terminal server named MOZART is swapped for a new DECserver 300 terminal server, which is given the same DECnet node name. The DECnet node address always stays the saIne with Swap. The new server also has the same service circuit-ID as the old server. (If you use Swap to change the characteristics of the same server, you have to specify the Ethernet address even though it will not change.) Your selection? 3 IRETI Type a ? at any time for help on a question. Type CTRL/Z for any question to return to the menu without changing the unit. IRET! What is the DEC net node name you want to swap? MOZART DECserver at Ethernet address 08-00-2B-02-24-DD is being modified. Enter the new Ethernet address, and any other DECnet characteristics you want to modify. DECserver type? [DS100] DS300 IRET! DECnet node name for unit? [MOZART] IRETI Ethernet address of unit? 08-00-2B-03-AA-AB DECnet Service Circuit-ID? [UNA-O] C-6 !RET! IRETI DECserver 300 Software Installation (VMS) C.2.5 Deleting a DECserver from the Database (Option 4) This example shows the deletion from the load host's node database of the existing server with the DECnet node name BACH. Your selection? 4 IRETI (Press CTRL/Z to return to menu.) Enter the DECnet node name of the server you want to delete? BACH %NCP-I-NMLRSP, listener response - Success Remote node = 28.1001 (BACH) %NCP-I-RECDELET, Database entry deleted IRETI If you use the List option to get a listing of servers, you see that BACH no longer appears. C.2.6 Restoring Existing DECservers to the Database (Option 5) This example shows the restoration of the local down-line load database. Your selection? S IRETI Restoring existing DECservers to host DECnet database ... Host DECnet database successfully restored. C.3 Example of Verification: Verifying a Load Host Installation The following example, presented in six parts, shows the installation verification for a VMS load host. This procedure tests that your VMS system can perform successfully as a down-line load host for a particular server. In this example, the VMS system is named SYSTEM. The server that is loaded is a DECserver 300 ternlinal server with DECnet node name BEETHO. BEETHO is an existing server currently operating on the network. This example assumes that the down-line load is performed during normal working hours and that server users are warned of the upcoming down-line load by way of RCF. C.3.1 Using RCF and Warning Server Users This example uses the server's default log-in password, ACCESS. $ MCR NCP CONNECT NODE BEETHO SERVICE PASSWORD FF23 Console connected (press CTRL/D when finished) IRETI IRETI * ACCESS IRETI (not echoed) DECserver 300 Terminal Server V1.0 (BL7) - LAT VS.1 Please type HELP if you need assistance Examples: Installation, Configuration, Verification C-7 Enter username> SWINSTALLER Local>SET PRIVILEGED IRETI IRETI IRETI Password> password (not echoed) Local> BROADCAST ALL "The server will be reloaded in 3 minutes." Local> IRETI I CTRLlO I $ C.3.2 Enabling DECnet Event Logging and Checking Server Names IRETI IRETI IRETI NCP> SET LOGGING CONSOLE EVENT 0.3,7 NCP> SET LOGGING CONSOLE STATE ON NCP> SET LOGGING MONITOR STATE ON NCP> EXIT IRETI $ SET DEFAULT MOM$LOAD $ @DSVCONFIG IRETI IRETI You must assign a unique DECnet node name and DECnet node address for each DECserver you are going to configure. Press <RET> to start, or <CTRL/z> to exit ..• IRETI DECserver Configuration Procedure version: Vl.8 1 2 3 4 5 CTRL/z Your selection? 1 Menu of Options List known DECservers Add a DECserver Swap an existing DECserver Delete an existing DECserver Restore existing DECservers Exit from this procedure IRETI DECnet DECnet Server Service Address Name Type Circuit Ethernet Address 28.1002 BEETHO DS300 UNA-O Load File Dump File 08-00-2B-03-AA-2B SH1601ENG.SYS DS3BEETHO.DMP Total of 1 DECserver defined. C-8 DECserver 300 Software Installation (VMS) DECserver Configuration Procedure Version: V1.8 1 2 3 4 5 CTRL/Z Your selection? Menu of Options List known DECservers Add a DECserver Swap an existing DECserver Delete an existing DECserver Restore existing DECservers Exit from this procedure ICTRLlZ I $ C.3.3 Down-Line Loading with the LOAD Command $ MCR NCP LOAD NODE BEETHO PASSWORD FF23 IRETI C.3.4 DECnet Event-Logging Display after Issuing LOAD NCP> LOAD NODE BEETHO SERVICE PASSWORD FF23 IRETI DECnet event 0.3, automatic line service From node 4.205 (SYSTEM), 18-JUN-1989 01:35:20.47 Circuit UNA-O, Load, Requested, Node = 28.1002 (BEETHO) File MOM$LOAD:SH1601ENG, Operating system Ethernet address 03-AA-2B DECnet event 0.3, automatic line service From node 4.205 (SYSTEM), 18-JUN-1989 01:43:21.14 Circuit UNA-O, Load, Successful, Node = 28.1002 (BEETHO) File = MOM$LOAD:SH1601ENG, Operating system Ethernet address 04-AA-2B Examples: Installation, Configuration, Verification 08-00-2B- 08-00-2B- C-9 C.3.S Checking the Service Circuit This part is optional, and is presented in case the service circuit becomes disabled. Type the following command to verify that the service circuit, BNA-O, is enabled: NCP>SHOW CIR BNA-O CHARACTERISTICS IRETI Circuit Volatile Characteristics as of 17-Jun-89 08:23:45 Circuit = BNA-O =on =disabled = 4.378 (LKGRT3) =4 =64 =15 =Ethernet = 4.378 (LKGRT3) =90 state Service Designated router Cost Router priority Hello timer Type Adjacent node Listen timer NCP> If the state is disabled, first check that the system is not busy by typing the following command: NCP>SHOW KNOWN LINKS IRETI Known Link Volatile Summary as of 17-Jun-89 08:25:23 Link 33848 8615 34154 NCP> Node 2.632 (JOEDEV) 3.118 (MERLE) 4.54 (SMAUG) PID 24203120 2420372C 24203F2B Process Remote Link Remote User 34655 309 33388 MAIL CTERM DECNET_MAIL MCGREGOR POOR MAIL_34154 The example shows that there are three users. If you enable the circuit at this time, you will disable the current users. If the circuit is not busy, type the following commands to enable service circuit, BNA-O. IRETI NCP>SET CIR BNA-O STATE OFF NCP>SET CIR BNA-O SERVICE ENABLED STATE ON C-10 IRETI DECserver 300 Software Installation (VMS) C.3.6 Conclusion of a Load Host Installation Verification NCP> CLEAR LOGGING CONSOLE EVENT 0.3,7 NCP> EXIT !RET! !RET! $ C.4 Example of Verification: Verifying the Server System Installation This example shows the verification of a server system installation. This procedure tests the hardware, the correctness of the software version, and the ability of the new software to run successfully. It assumes that you are at a terminal connected to the server's Port 1, that your username is SWINSTALLER, that your user password is SQUIDS, that you will test the server by connecting to your own VMS system, SYSTEM, and that the new DEC server 300 software is Version 1.0. !RET! !RET! DECserver 300 Terminal Server Vl.O (BL7) - LAT V5.1 Please type HELP if you need assistance Enter username> SWINSTALLER !RET! Local> TEST PORT COUNT 5 WIDTH 65 !RET! !"#$%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]~_' !"#$%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]~_ 'a "#$%&'()*+,-./0123456789:i<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]I\_ 'ab #$%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]"_ 'abc $%&'()*+,-./0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]"_ 'abcd Local> SHOW PORT !RET! The display at the port of a new DECserver 300 terminal server should match the following example, which contains the factory-set values, except for the port number, user name, and server name: Port 1: SWINSTALLER Server: LAT_08002B03AA2B Character Size: Flow control: parity: XON None Input Speed: Output Speed: Modem Control: 9600 9600 Disabled Access: Backward Switch: Break: Forward Switch: Local None Local None Local Switch: Name: Session Limit: Type: None PORT_l 4 Soft 8 Examples: Installation, Configuration, Verification C-11 Preferred Service: None Authorized Groups: (Current) Groups: 0 0 Enabled Characteristics: Autobaud, Autoprompt, Broadcast,' Input Flow Control, Loss Notification, Message Codes, Output Flow Control, Verification Local> SHOW SERVICES ALL SUMMARY IRETI Service Name Identification Status DEVELOP DOCUMENT TEST TIMESHARING SYSTEM 2 Connected Available Unavailable Unknown Available Hardware Timesharing Service Ident Documentation Timesharing As usual Server Software Development VAX/VMS 8600 Local> CONNECT SYSTEM I~ETI Local -010- Session 1 to SYSTEM established SYSTEM -- VAX 8600, The Best for Down-line Loading IRETI IRETI (not echoed) Username: SWINSTALLER Password: SQUIDS Welcome to VAX/VMS version V5.0 on node SYSTEM Last interactive login on Wednesday, 17-JUN-1989 07:25 Last non-interactive login on Thursday, 27-MAR-1989 17:18 SYS$MANAGER:NOTICE.TXT -- SYSTEM System Notices 18-Jun-1989 All users, please purge your filest $ SHOW TIME IRETI 18-JUN-1989 07:00:09 $ SHOW USERS IRETI VAX/VMS Interactive Users Total number of interactive users Username Process Name PID DAISY DAISY 20A0257A HEATHER HEATHER 20A02217 20A020D2 IVY IyY ROSE ROSE 20A02321 SWINSTALLER SWINSTALLER 20A02001 18-JUN-1989 07:00:13.13 4 Terminal VTA3341 VTA3391 VTA3234 VTA3471 VTA3471 LTA3341 : LTA3391 : Disconnected LTA3471: LTA3511 : $ LOGOUT IRETI SWINSTALLER logged out at 18-JUN-1989 07:00:20.98 Local -011- Session 1 disconnected from SYSTEM Local> LOGOUT IRETI Local -020- Logged out port 1 on server LAT_08002B03AA2B C-12 DECserver 300 Software Installation (VMS) Index A Aborting the installation, 2-2 Alternate load hosts assignments, 2-9 installing software onto single systems, 2-10 recommendation, 2-1 requirements, 2-9 using, 2-10 B BROADCAST command example, C-8 using RCF to issue, B-1 C CLEAR LOGGING CONSOLE EVENT command, C-11 Command procedures see DSVCONFIG.COM see VMSINSTAL.COM Commands BROADCAST, B-1, C-8 Commands (cont' d.) CLEAR LOGGING CONSOLE EVENT, C-11 CONNECT, 4-4, B-1, C-7, C-12 CREATE, 2-6 DEFINE, 2-7, 2-8 INITIALIZE, 4-2 LOAD, 4-1, C-9 LOGOUT, 4-4, C-12 SET CIRCUIT, 3-9, C-10 SET DEFAULT, 3-4, C-2, C-5, C-9 SET LOGGING CONSOLE EVENT, C-9 SET LOGGING CONSOLE STATE, C-9 SET LOGGING MONITOR STATE, C-9 SET PRIVILEGED, C-8 SHOW CIRCUIT, C-10 SHOW KNOWN LINKS, C-10 SHOW LOGICAL, 2-8 SHOW NODE, 3-3 SHOW PORT, 4-3, C-11 SHOW SERVER, 4-3 SHOW SERVICES, 4-3, C-12 SHOW TIME, C-12 SHOW USERS, C-12 Index-1 Commands (cont'd.) TEST PORT, 4-3, C-11 Configuration of node database see Node database CONNECT command, 4-4, B-1, C-7, C-12 Conventions of DSVCONFIG.COM, 3-1 to 3-2 of VMSINSTAL. COM, 2-1 Coordinating with server manager, 4-4 CREATE command, 2-6 D Databases keeping synchronized, 3-8 list of, 1-5 overview, 1-5 DECnet, 3-2, 3-4 DECnet commands, 1-4 DECnet databases, 3-3 DECnet error messages, 3-8 DECnet event logging see Event logging DECnet node address description, 3-3 ensuring uniqueness, 3-3 specifying, 3-6 DECnet node name description, 3-3 ensuring uniqueness, 3-3 specifying, 3-6 DECnet operational database, 1-5, 3-6 DECnet permanent database, 1-5, 3-6 DECnet Phase IV see DECnet DECnet warning message, 2-3 Index-2 DECserver 300 Identification Card, 3-2 to 3-3, 3-6, 3-9 DECserver 300 Software Product Description, 1-6 DECserver type, 3-6 Default-id, 3-7 DEFINE command, 2-7,2-8 Device-identifier, 2-3 Disk space requirements, 2-2 Distribution files, 2-7, A-1 to A-2 Distribution media, 2-2, 2-4 Distribution software directories, 3-2 disk space required, 2-2 file names, A-1 in distribution kit, 1-1 media, 2-2 Down-line loading definition, 1-1 disk space required, 2-2 for verification, 4-1 load file nal11e, A-2 with LOAD command, 4-1, C-9 DSVCONFIG. COM actions, 3-4 to 3-5 adciing servers, 3-6 to 3-7 conventions, 3-1 to 3-2 different versions of, 3-1 enabling service circuit, 1-4 error, 3-7 example of, C-4 Add option, C-6 Delete option, C-7 List option, C-5 Restore option, C-7 Swap option, C-6 exiting from, 3-9 invoking, 3-4 listing servers, 3-6 menu, 3-5, C-5 merge messages, 3-8 DSVCONFIG.COM (cont'd.) option 1, 3-6 option 2, 3-6 option 3, 3-8 option 4, 3-8 option 5, 3-8 overview, 1-4 requirements, 3-1 to 3-2 running the procedure, C-5 using for DECserver 100 terminal servers, 3-1 using for DECserver 200 terminal servers, 3-1 using for DECserver 500 terminal servers, 3-1 DSVCONFIG.DAT contents of, 3-6 definition, 1-5 DSVCONFIG_SPECIFIC.DAT, 3-9 E Error messages, 3-7 Ethernet address, 3-3, 3-7 Event logging disabling, C-ll enabling, C-8 example of, C-9 messages, 4-1 reading the messages, C-9 F File names, A--,l G Group numbers, 4-3 H Hardware, 4-1, 4-2 Identification card see DECserver 300 Identification Card INITIALIZE command, 4-2 Installation, 2-10 aborting, 2-2 disk space required, 2-2 example of, C-1 to C-4 flow chart, 1-2, 1-3 onto alternate load hosts, 2-9, 2-10 onto other operating systems, 2-10 overview, 1-1, 1-4 procedure see VMSINST AL. COM recomnlended procedure, C-1 verifying, 4-1 Installation Verification Procedure initiating, 2-6 location, 2-7 overview, 1-4 IVP see Installation Verification Procedure L LOAD command, 4-1, C-9 Load host's node database see Node database Load hosts alternates, 2-1 disk space requirements, 2-2 primary, 2-2 recommended number, 2-1 VAXc1usters as, 3-8 Index-3 Loading see Down-line loading LOGOUT command, 4-4, C-12 M Merge on VAXcluster nodes, 3-8 to 3-9 MOM$LOAD, 2-6; 2-8 to 2-9, 3-4 N Network Control Program (NCP) commands see Commands messages, 3-7 Node database configuration overview, 1-4, 1-5 example configuration, C-4 o Optional products, 1-6 OPTIONS G, 2-10 OPTIONS N, 2-3 p Passwords server maintenance password, B-1, B-2 service password (DECnet service password), B-1, B-2 Prerequisite products, 1-6 R RCF connecting to node, B-1 disconnecting from node, B-2 Index-4 RCF (cont'd.) example of use, C-7 using to issue BROADCAST, B-1 Release notes checking, 2-10 directory in, 2-5 displaying, 2-3, 2-4 file natne, 2-4, A-2 printing, 2-3, 2-4, 2-5, C-l, C-2, C-5 Release notes options menu, 2-4 Remote Console Facility see RCF s Savesets, 2-3, 2-10 Server configuration database see DSVCONFIG.DAT Server image, I-I, 1-6, 2-6, 4-1, 4-2 Server software see Distribution software see Server image Service circuit checking, C-I0 enabling automatically, 1-4 enabling manually, C-I0 types, 3-7 SET CIRCUIT command, 3-9, C-I0 SET DEFAULT command, 3-4, C-2, C-5, C-9 SET LOGGING CONSOLE EVENT command, C-9 SET LOGGING CONSOLE STATE command, C-9 SET LOGGING MONITOR STATE command, C-9 SET PRIVILEGED command, C-8 SHOW CIRCUIT command, C-I0 SHOW KNOWN LINKS command, C-I0 SHOW LOGICAL command, 2-8 SHOW NODE command, 3-3 SHOW PORT command, 4-3, C-11 SHOW SERVER comlnand, 4-3 SHOW SERVICES command, 4-3, C-12 SHOW TIME command, C-12 SHOW USERS conlmand, C-12 Software license, 2-2, 2-6 Synchronizing databases, 3-8 System disk back up, 2-2, 2-3 disk space required, 2-2 System installation definition, 4-1 System start-up file, 2-7 to 2-8 T Terminal Server Manager see TSM Testing server commands for verification, 4-1 TEST PORT command, 4-3, C-11 TSM, 1-1, 2-7, A-1, A-2 u Up-line dumping disk space required, 2-2 received by load host, 2-9 Verifying the installation of load host, 4-1 by down-line loading, 4-1 example of, C-7 to C-11 disabling event logging, C-11 down-line loading, C-9 event logging, C-9 LOAD command, C-9 using DECnet event logging, C-8 using RCF, C-7 warning server users, C-7 of server system, 4-2 example of, C-11 to C-12 VMSINSTAL aborting, 2-2 conventions, 2-1 displaying release notes, 2-3, 2-4 example of, C-1 exiting, 2-7 invoking, 2-3 overview, 1-4 printing release notes, 2-3, 2-4, 2-5, C-1, C-2, C-5 restarting, 2-5 running on VMS V5.0, C-1 VMS tailoring classes, 2-2 v VAXclusters as load host, 3-8 installing distribution software onto, 2-6 merge procedure, 3-4 to 3-5 verifying merge, 3-8 to 3-9 Index-5 DECserver 300 Software Installation (VMS) AA-NE45A-TE READER'S COMMENTS What do you think of this manual? Your comments and suggestions will help us to improve the quality and usefulness of our publications. Please rate this manual: Poor Accuracy Readability Examples Organization Completeness 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 Excellent 5 5 5 5 5 Did you find errors in this manual? If so, please specify the error(s) and page number(s). General comments: Suggestions for improvement: Name _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Date _ _ _ _ _ _ _ _ _ __ Title _ _ _ _- _ _ _ _ _ _ _ _ _ _ _ _ _ _ Department Company _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Street City_ _ _ _ _ _ _ _ _ _ State/Country _ _ _ _ _ _ _ _ Zip Code _ _ __ DO NOT CUT - FOLD HERE AND TAPE 111111 BUSINESS REPLY LABEL FIRST CLASS PERMIT NO. 33 MAYNARD MASS. POSTAGE WILL BE PAID BY ADDRESSEE momDDmO™ Networks and Communications Publications 550 King Street Littleton, MA 01460-1289 DO NOT CUT - FOLD HERE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies