Digital PDFs
Documents
Guest
Register
Log In
EK-KCRSC-FS-2
July 1987
64 pages
Original
2.1MB
view
download
Document:
Remote Services Console Field Service Manual
Order Number:
EK-KCRSC-FS
Revision:
2
Pages:
64
Original Filename:
OCR Text
EK-KCRSC-FS-002 Remote Services Console Field Service Manual EK-KCRSC-FS-002 Remote Services Console Field Service Manual Digital Reid Service Engineering Stow, Massachusetts First Edition March 1986 Second Edition July 1987 Copyright O 1986 and 1987 by Digital Equipment Corporation All rights reserved The reproduction of this material, in part or whole, is strictly prohibited. For copy information, contact the Educational Services Department, Digital Equipment Corporation, Maynard, Massachusetts 01754. The information in this document is subject to change without notice. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this manual. Printed in U.S.A. The following are trademarks of Digital Equipment Corp~ration, Maynard, Massachusetts. mamaamr DEC DECmate DECnet DECsystem-10 DECSYSTEM-20 DEC US DECwriter DIBOL MAS SB US PDP Professional Rainbow RSTS RSX UNIBUS VAX VMS VT Work Processor CONTENTS INTRODUCTION Scope •••••••• RSC Overview Certifications Related Documents v v vi vii CHAPTER 1 INSTALLATION 1. 0 1.1. l 1.1. 2 1.1. 3 1.1. 4 1.1. 5 1.1. 6 1. 2 1. 3 Introduction Site Preparation Telephone Line Modem •••••••••• CPU Communications Port AC Power •.••••• Console Terminal and Comm Port Cables Accessibility Installation Procedure Removing the RSC Unit CHAPTER 2 OPERATION 2.1 2.2 2.3 2.4 2.5 2.6 2.6.1 2.6.2 2.6.3 2.6.4 2.7 2.8 Introduction ••.••.•• Summary of Operation POWER Indicator FAULT Indicator Data Rate Switches Keyswitch REMOTE LOCKOUT USER PORT REMOTE USER Console Terminal Messages Local Copy Switch ••••••.• CHAPTER 3 TROUBLESHOOTING 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 Introduction •••••••••••••• Troubleshooting Procedures Cable Test and RSC Bypass Power-up Test USER PORT Test Telephone Line and Modem Test REMOTE USER Test REMOTE Test •••••••••••• 1.1 iii 1-1 1-1 1-1 1-1 1-2 1-2 1-3 1-3 1--3 1-20 2-1 2-1 2-9 2-9 2-10 2-10 2-11 2-11 2-12 2-12 2-12 2-13 3-1 3-1 3-1 3-2 3-3 3-3 3-3 3-4 APPENDIX A USER GUIDE INDEX TABLES 2-1 2-2 2-3 2-4 2-5 3-1 Generic Systems Operator Information •••••••••••• VAXcluster Operator Information ••••••••••••••••• Local VAX/PC38N Console Operator Information •••• Commands Used by the Remote Station (Host) • • • • • • Other Switches and Indicators ••••••••••••••••••• Troubleshooting Chart • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-2 2-3 2-4 2-5 2-9 3-5 FIGURES 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 2-1 2-2 2-3 2-·4 A-1 Voltage Select Switch and Fuses ••••••••••••••••. Language~specific Label Installation •••••••••••• Front Panel Switch Locations ••••••.•••••.•.•••.. Generic RSC Installation Overview •••••••••••••.• VAX/PC38N RSC Installation Overview ••••••••.••.. VAXcluster RSC Installation Overview ••••••••••.• RSC Cable Configuration Plan •.••••••••••••.•••.• EIA Cable Connectors ••••••••••••••••••••••••.•.• Data Rate Switches •••••••••••.•••••••••••••••••• Field Transaction Report •••••.••••••••.••••.••.• Typical Printout For VAX Console "Show Status" .• Keyswitch Positions REMOTE and LOCKOUT ••••••••.. Keyswitch Positions USER PORT and REMOTE USER ••. Data Rate Switches ••••••••••••••••••••.••••••••• RSC User Guide ••••••••••••••••••••••••.••••.••.• iv 1-4 1-5 1-6 1-8 1-9 1-10 1-12 1-14 1-15 1-24 2-6 2-7 ·2-8 2-10 A-2 RELEASE NOTES FOR REMOTE SERVICES CONSOLE FIELD SERVICE MANUAL REVISION 002 +---------------------------------------------------------------+ o This revision includes ECO changes that resolved the problem of garbled or echoed characters when both the customer and the CSC enabled Local Copy (see page 2-13). o To reflect software changes, all references to the (RD) console display message pref ix have been changed to (RSC 001). o We have added specific installation information for VAX/PC38N systems (VAX with PC38N console) beginning on page 1-17. o Software changes that resolved the VAX/PC38N TALK mode problem are reflected in Table 2-4 on page 2-5. o Some information about "smart" modems has been added on page 1-2. +---------------------------------------------------------------+ v INTRODUCTION SCOPE This manual provides information for Digital Field Service personnel who install, test, and operate the Remote Services Console option (RSC) • Chapter 1 Installation Provides a step-by-step procedure for installing the option. It also gives a procedure for removing it. Chapter 2 Operation --Describes switch settings for local and remote operations and tells you what the indicators mean. Most of this information is also included in the Site Management Guide for the customer's use. Chapter 3 Troubleshooting Tells you how to solve problems caused by wrong switch settings, cable connections, and other faults external to the RSC unit. The RSC unit is to be swapped if an internal fault occurs. RSC OVERVIEW The Remote Services Console (RSC) is a microprocessor-controlled data path switch. RSC is a Digital Field Service "tool" and is not for sale. It will be used for remote services delivery and offers the following features. o Does not require a dedicated modem and telephone line. A customer may have a communications port application using a modem and telephone line. If so, RSC can share the modem and telephone line for other remote services (including remote diagnosis). o Gives remote access to the system communications port using Remote Diagnosis Service Protocol (RDSP). remote user can log in to the system through a communications port for any authorized application. RDSP protocol is enabled to ensure data integrity. A vi o Switch-controlled LOCKOUT A customer can set the RSC front panel keyswi tch to disable all remote access to the system through the RSC modem port. The key can be removed for additional security. o Data rate is selectable by front panel switches. The RSC interfaces operate with their data rates set to match the data rates of the system console terminal and the modem. If the modem or console terminal data rate is changed, there is no need to open the RSC enclosure. The switches on the front panel set RSC to the matching modem or terminal data rate. o 9600 bits per second (b/s) capability RSC operates at data rates of 9600 b/s. o 300, 1200, 2400, 4800, or Easier Troubleshooting A technician or operator can disconnect cables from the RSC unit and patch them together for testing. There is no need to open system enclosures. This makes it easy to find a cable fault or to temporarily bypass the RSC unit if it fails. CERTIFICATIONS The Remote Services Console certifications. (MDSOl) FCC Class A VOE Class B - DBP Directive 1046/84 Underwriters Laboratory Listed 708A IEC 435 Classified CSA Australia - C83/7/903A PTT Approved: Germany Belgium Finland Japan Sweden Number ZA301096U vii has received the following Bescheinigung des Her.stellers/I mporteurs Hiermit wird bescheinigt, da8 der/die/das ....~.!?.~.~-~.....~.:.:..~~-~..~.S.~.~-~-=~=.':~.~..................................................................... (Gerlt. Typ. Bezeichnung) in Obereinstimmung mit den Bestimmungen der ....~.~-~--~-~--==-~.!.~.9.~~S.....1.~.~-~!..~~........................................................................... (Amt8bi.ttverfilgung) funk-entst6rt ist Der Deutschen Bundespost wurde das lnverkehrbringen dieses Gerates angezeigt und die Berechtigung zur Oberpl'Ufung der Serie auf Einhaltung der Bestimmungen eingeriiumt DIGITAL EQUIPMENT GMBH ~;.;·;;~·;;;;;~;;;i.;;;;;;;·····;:;:e-iscF\atisf"iasa··9-:r··· ............................... 8000 MUNCHEN 81 Telefon (089) 95 91-0 Telex 5/215780, Telefax 95911010 All other applicable approvals have been applied for. RELATED DOCUMENTS Other remote diagnosis manuals cover, in greater detail, related subjects such as site preparation, general modern information, and working with the Digital Customer Support Center (CSC). KBDOl Options Technical Manual (EK-KBDOl-TM) KC730 Remote Diagnosis Option Technical Manual (EK-KC730-TM) KC780 Family Remote Diagnosis Options Technical Manual (EK-KC780-TM) viii CHAPTER 1 INSTALLATION 1.0 INTRODUCTION This chapter provides information needed for an RSC installation. It begins with site preparation, continues with a step-by-step installation procedure, including testing, then tells you how to remove an RSC unit. NOTE The RSC unit is to be installed only during the period of system warranty or under the terms and conditions of a maintenance contract. RSC remains the property of Digital; it is not for sale. 1.1 SITE PREPARATION Before you install the RSC unit, you will have to check for each of the following items. o o o o o o o 1.1.1 A telephone line A modem The CPU communications port AC power for the RSC unit Console terminal and comm port cables Accessibility For all VAX/PC38N systems (any VAX with a PC380 console) 17-01337-01 adapter is required. (See Step 2 of the installation procedure.) a Telephone Line If there is no telephone 1 ine to the system, the customer wi 11 have to arrange for one to be installed. It should be, at a minimum, a voice grade line that supports up to 1200 b/s operation. The telephone company may ask the customer to give them certain information about the modem that will be connected to the line. An example of the required information is given in Paragraph 1.1.2. 1.1.2 Modem The customer is required to supply, and have installed, a modem that is suitable for RSC remote operation. The modem must be RS-232-C compatible, comply with Digital Standard 052, and provide tne Automatic Answer feature. All modems manufactured by Digital meet the above criteria. 1-1 Note that some "smart" modems are software-controlled and cannot be used because the signals specifically used by RSC (DSR, DTR, CTS, and DCD) are "forced on" or tied high. Also, a modem that has jumpers or switches to change signal options may be used by a customer in a non-compatible configuration. You will want to avoid the use of such a modem because of the problem of changing the configuration each time it is to be used for remote services. Before the modem is installed, the telephone company may ask the customer to give them information about the modem. For example, the information needed for Digital DF03 or DFll 2 modems is as follows. MANUFACTURER Digital MODEL DF03-AA or DF112-AA FCC REGISTRATION NO. DF03-AA - A0994Q-69391-DM-R DF112-AA - A0994Q-13634-DM-E RINGER EQUIVALENCE DF03-AA - 0.3, Type A DF112-AA - 0.3, Type B DATA RATE 300/1200 b/s The RSC modem interface supports data rates of 300 to 9,600 bits per second (b/s). Thus, RSC allows both the customer's CPU comm port and Digital's Remote Services Delivery to operate at speeds up to and including 9600 b/s. 1.1. 3 CPU Communications Port Most customer systems have at least one communications port (DZ, DMF, DMB) being used with a modem and a telephone line. You can connect the port through the RSC unit, sharing the port and the modem for both the customer's operations and remote services. If the customer has not implemented a CPU comm port, there is no need to do so when RSC is installed. RSC does not need to have a comm port connection, but can support one. A comm port can be implemented easily at any time if the customer wants to time-share the modem. 1.1. 4 AC Power The RSC unit requires an ac receptacle for its power. There is a 120/240 voltage select switch on the RSC rear panel that must be set to the local voltage. The RSC unit should be connected to an AC power receptacle that a) is not switched by the CPU power controller and, b) cannot be switched off accidentally. Even when all or part of the computer system is down, the RSC unit may be required for remote service. 1-2 1.1.5 Console Terminal and Comm Port Cables The RSC external interfaces are EIA, RS-232-C compatible and operate with RS-423 equipment. For control of emissions, the cables used with RSC should be shielded, Digital BC22E or BC22F or equivalent. 1.1.6 Accessibility The RSC unit must be installed so that it is accessible. The operator must be able to set the keyswitch and data rate switches and see the indicators. If the modem also has front panel data rate switching, the RSC unit and the modem should be close together. The installation procedure helps you use the available cables to put the RSC unit in the most convenient place. 1.2 INSTALLATION PROCEDURE STEP 1 Make sure that you have prepared the site. See Paragraph 1.1. STEP 2 Unpack the option kit and make sure you have all that they are not damaged. the parts and The kit includes the following items. 1 RSC Unit 1 Power Cord (factory ships with 120 volt, parallel blade male plug) 1 BC22F-10 Cable 1 BC22F-25 Cable 1 RSC Field Service Manual, EK-KCRSC-FS 1 RSC User Guide, EK-KCRSC-UG 1 RSC User Guide, EK-KCRSC-SM 1 Accessory Kit 70-23715-01 (contains the following items) 1 Language-specific Label Set 1 Fuse Carrier, 12-21126-04 1 Fuse, 12-19283-19, .50A, 5mm. .25A, 5mm. 1 Fuse, 12-19283-16, 2 Keys 1 Field Transaction Report Form, EN-01748-12 +---------------------------------------------------------------+ VAX/PC38N NOTE An EIA adapter, part number 17-01337-01 is required for VAX/PC38N installation. The adapter is not shipped with the RSC option. The adapter is shipped with each VAX/PC38N and should be present on-site. 1-3 STEP 3 WARNING ALL RSC units are shipped with the voltage select switch set for 120 volt operation and a 3AG, .SA Slow Blow fuse. Damage may result if the unit is connected to any other power source before Step 3 is completed. In this step you will prepare the RSC unit for connection to ac power (Figure 1-1). o Remove the receptacle. yellow warning label that covers o Set the voltage select switch for operation on the local ac voltage supply, 100/120 or 220/240 Vac nominal. o For 120V operation, leave the 3AG .SA fuse in place. o For lOOV operation, remove the 3AG .SA fuse and insert the .SA, Smm fuse with the Smm carrier. o For 220/240V operation, remove the 3AG .SA fuse and carrier and insert the .2SA, Smm fuse with the Smm carrier. \ \ / / / / Figure 1-1 Voltage Select Switch and Fuses 1-4 ac carrier~and 5mm FUSE WITH CARRIER 3AG FUSE WITH CARRIER the STEP 4 Place the RSC unit so it is standing up on its rear panel. Select the applicable local language label from the language-specific label set. Peel the label away from the backing sheet (handle the label by its edges). Align either the right hand or left hand edge of the label within the recessed area on the front of the unit. Guide it gently into position and, when it is correctly aligned, press it down firmly. (See Figure 1-2) Figure 1-2 Language-Specific Label Installation 1-5 STEP 5 In this step you do a preliminary, RSC unit. basic operation test of the o Set the RSC keyswi th to REMOTE USER. location of the front panel switches. o Plug in cables.) o The POWER switch) • o The FAULT indicator should come on for about (during the power-up self-test), then go off. o Test each of the four positions of the keyswitch. Make sure that each corresponding indicator comes on. The REMOTE and REMOTE USER indicators should blink. o Press the LOCAL COPY switch in and latch it. Test each of the four positions of the keyswi tch. The LOCAL COPY indicator should come on only when the keyswitch is in the REMOTE position. POWER the ac power indicator FAULT cord. (Do not should come on REMOTE (there 0 \ 0 connect USER PORT LOCKOUT 0 0 Figure 1-3 shows the \ \ I I any other no power one second is LOCAL COPY x I REMOTE USER 0---------0----------0 ----------------------------------------------------~------------ Figure 1-3 Front Panel Switch Locations 1-6 STEP 6 Ask the customer to assign an account number and password for the Customer Support Center (CSC) to use. Call the CSC, give them their account number and password, and ask them to schedule a test when you finish the installation. STEP 7 Arrange with the customer to have use of the system during installation and testing. Figures 1-4, 1-5, and 1-6 show the basic steps involved in an RSC installation. You will not need to shut down the system, but the customer needs to know when you are disconnecting cables and doing tests. For example, disconnecting a console terminal cable while a message is being received could cause a system problem. Make sure that the console terminal is working correctly and that. there are no problems that might interfere with RSC operation or testing. If the customer has a modem and telephone line working on a communications port, test them for correct operation also. +---------------------------------------------------------------+ VAXcluster NOTE I A VAXcluster node may not have a dedicated console terminal. I I STEP 8 Before you begin installation, check the lengths of the cables that you will use and make sure that you can put the RSC unit where the customer wants it. Two cables are supplied in the RSC kit and you will also use the following cables that are already at the site. o The cable that connects the console terminal to the CPU console terminal port (not on VAX/PC38N). This cable is a BC22D or equivalent (female/female) and will be used to connect the console terminal to the RSC unit in Step 11. o If the CPU comm port has been implemented, connects the modem to the CPU comm port. the cable that I +---------------------------------------------------------------+ VAX/PC38N NOTE The VAX\PC3$N does not have a traditional console terminal; you will be connecting a cable from RSC to the VAX Console System Remote Port in Step 11. 1-7 CPU ORIGINAL SYSTEM CONSOLE TERMINAL PORT COMM PORT IMPLEMENTATION OPTIONAL COM PORT CONSOLE TERMINAL MODEM CPU DISCONNECT CABLES FROM CONSOLE TERMINAL AND MODEM (MODEM MAY NOT BE PRESENT) CONSOLE TERMINAL PORT COM PORT CONSOLE TERMINAL MODEM CPU CONNECT NEW CABLES TO CONSOLE TERMINAL AND MODEM (MODEM REQUIRED) CONSOLE TERMINAL PORT COM PORT TERMINAL CPU CONNECT CABLES TO RSC UNIT CONSOLE TERMINAL Figure 1-4 CONSOLE TERMINAL POAT ..,_ \ r· ~1!1EMOTE~\ SERVICES CONSOLE COM PORT COMM PORT IMPLEMENTATION OPTIONAL a.. ..z_ '7 Generic RSC Installation Overview 1-8 MODEM rn DISPLAY ....._.... KEYBOARD VAX CONSOLE (PC38N) ~ PRINTER REMOTE PORT PORT 1 l J~ VAX CPU ~~ r----, I COMM I ~ ....._ 1-- I POAT l 1 COMM 1 ~~ 11 IvJ LA50 PRINTER ADAPTER I 7 ' I I I I I I I I I '\\ I I I A1 81 L.:----~~----~- .__,.J~ - - - - ~ ._ - \ - I _._J \ \ \ \ \ A2 f\ 82 _:,! ' REMOTE SERVICES CONSOLE ,..._ __________ ~~-------------------.-------------' ' ...... Figure 1-5 I --- / / / MODEM VAX/PC38N RSC Installation Overview 1-9 THIS PAGE IS RESERVED FOR VAXcluster INFORMATION WHICH WAS NOT AVAILABLE J::>RIOR TO THE PUBLICATION DATE' OF THIS MANUAL Figure 1-6 VAXcluster RSC Installation Overview 1-10 You can use Figure 1-7 to plan how to configure the RSC cables. The cables may be of different lengths, but most of them are interchangeable. When you know where the customer wants the RSC unit installed, you can plan where each cable should be used. CABLE NOTE 1. The cable connecting the local console terminal to the CPU console terminal port will be a BC22D. It is not interchangeable with the other cables being used with RSC, and it must be connected to the CPU console terminal port and RSC connector A2 (in Step 11). 2. The other cables must be BC22E or BC22F or equivalent and they are all interchangeable. These are required because RSC implements full modem control. STEP 9 Follow your cabling plan in Figure 1-7 when you disconnect the system cables. Your plan should identify the cable connectors you will disconnect and the ones you will not have to disturb. Disconnect the BC22D cable from the console terminal, leaving it connected to the CPU Console Terminal port (does not apply to VAX/PC3 SN) • STEP 10 For all systems including VAX/PC38N, if the comm port has been implemented, disconnect the cable that connects the CPU comm port to the modem. You may not need to disconnect both ends of the cable. +---------------------------------------------------------------+ VAX/PC38N NOTE If there is a cable connected from the modem to the VAX Console System Remote Port (COMM PORT 1), disconnect it. 1-11 Before you beg in to move hardware around, you may want to use the space on the facing blank page to sketch out and plan the installation. It can help you decide: o Where you will use each available cable; o Whether you will need longer cables to be able to put the hardware where the customer wants it; o Which cable connectors are already in the right place and won't have to be disturbed. All systems except VAX/PC38N have a BC22D connecting the CPU Console Terminal Port to the Console Terminal. This cable must remain connected to the CPU Console Terminal Port. # Any system MAY have a Modem. cable connecting VAX/PC38N Systems MAY have a cable System Remote Port ~a modem. (These two cables are supplied in the option kit.) Figure 1-7 Length the CPU Comm Port to a # Length connecting the # Length !~£22F-~~ Length ____ 2_5_'~- VAX Console 10' RSC Cable Configuration Plan 1-12 WORKSHEET FOR USE WITH FIGURE 1-7 1-13 STEP 11 Put the RSC unit (and the modem) where you are going to install them. Follow your cabling plan in Figure 1-7 and connect the cables as shown in the table below. Note that the RSC does not require that a CPU comm port be implemented, but if there is one, Digital recommends that it be connected to the RSC. Figure 1-8 shows the locations of the connectors. SYSTEMS All All All All Generic Generic Generic Generic VAX/PC38N VAX/PC38N VAX/PC38N VAX/PC38N CONNECT CABLE FROM- Systems Systems Systems Systems TO RSC CONNECTOR Local Console Terminal Al A2 CPU Console Terminal Port (BC22D) CPU Comm Port Bl Modem B2 Hardcopy Terminal * Console System Remote Port CPU Comm Port * Modem ** Al A2 Bl B2 VAXcluster Information will be added at the next revision. * ** Implementation is optional. Install adapter 17-01337-01 at the PC38N VAX Console Remote Port. (It can be installed, optionally, at RSC connector A2.) Figure 1-8 EIA Cable Connections 1-14 STEP 12 Determine the data rate at which the modem will operate. This will be typically 1200 b/s (but could be 300 b/s) for CSC operations. Set the RSC modem data rate switches (BAUD M) to. that rate (see Figure 1-9). STEP 13 Determine the data rate at which the CPU console terminal is operating (use the SETUP key). Set the RSC terminal data rate switches (BAUD T) to that rate. Note that the local terminal must be set up for 8 Bit, No Par~ty operation. +---------------------------------------------------------------+ I VAX/PC38N NOTE The VAX Console Remote Port is.not a traditional console terminal port; it is a modem control port. Set the BAUD T switches to 1200 b/s. You will set the VAX Console Remote Port to 1200 b/s in Step 14. 1 BAUD M BAUD T 1 2 3 1 2 3 ((((((0 SET RSC DATA RATE SWITCHES TO THE SAME DATA RATE AS THE CONSOLE TERMINAL (BAUD T) AND THE MODEM (BAUD M) 3 I l Il Il 300 ....c::::L I l l l 1200 _o_ ...c::L _o_ I l l l ....c::::L 2400 ·4800 ..c::L.. IN _CJ_ Figure 1-9 2 ...c:L OUT ..c::L 9600 _o_ Data Rate Switches NOTE You have completed the hardware installation and, beginning at Step 14, you will test system operation. Since the VAX/PC38N and generic systems test procedures are so different, .the following steps are separated onto opposite pages. A header on each page indicates which system the page is to be used for. 1-15 GENERIC SYSTEMS TEST STEP 14 GENERIC SYSTEMS TEST In this step you will test operation of the CPU Console Terminal port. o If the CPU has a LOCAL/REMOTE switch, set it to LOCAL. o Make sure the modem has power. The should come on. o Plug in the RSC power cord. o Set the RSC keyswitch to should come on, blinking. o RSC transrni ts the message "(RSC 001) REMOTE PORT ENABLED" which should be printed on the console terminal. o Use a nearby telephone and dial the number of the telephone line that is connected to the modern. o The modern DSR and CAR indicators should hear a carrier tone. o Within 30 seconds, the modern should time-out and drop the line. You can then hang up the telephone. o RSC transmits the message "(RSC 001) CONNECTION LOST" which should be printed on the console terminal. o The DSR and CAR indicators should go off but the DTR indicator will remain on. The message "(RSC 001) REMOTE PORT ENABLED" should be printed on the console terminal. STEP 15 modem REMOTE. The should DTR indicator REMOTE indicator come on and you GENERIC SYSTEMS TEST In this step you will test the CPU communications port. Note that RSC can support a comm port but does not require one for its operation. o Set the RSC keyswitch to REMOTE USER. o The REMOTE USER indicator should come on, blinking. o Test the console terminal for normal operation by typing on the keyboard. o The modem DTR indicator should be on. o Use a nearby telephone and dial the number of the telephone line that is connected to the modem. 1-16 VAX/PC38N TEST STEP 14 VAX/PC38N / RSC PREREQUISITES In this step you will check to make sure the prerequisites for RSC operation are present. Check the VAX Console Communications Set-up Line Characteristics Menu and see that both Transmit and Receive speeds are set to match the modem speed and that Connection Type is modem (see the VAX/PC38N Console User Guide) • STEP 15 VAX/PC38N SET-UP At this step you will display the VAX Console set-up, check to see if the settings are correct for RSC remote operation, then make any necessary changes. At the >>> prompt, following printout: enter a Show Status command and get the +--------------------------------------------------------------------+ >>>SH S Printer ENABLED, ONLINE. Remote Carrier:ABSENT. Remote user:ENABLED; console:ENABLED; modem:ENABLED; monitoring:ENABLED Program Mode settings: LOCAL=OPAO REMOTE=OPA(4 or 5) +-------------------------~------------------------------------------+ o Make sure that the printer (the LASO connected to the VAX console printer port) is enabled. o Make sure that Remote User, Remote Console, Remote Modem, and Remote Monitoring are enabled. o Make sure that the Program Mode settings are as shown. You may have to change REMOTE to OPA4 or OPAS as required for remote access. You can ask the local operator to help or see the VAX Console User Guide for instructions. 1-17 GENERIC SYSTEMS TEST STEP 15 GENERIC SYSTEMS TEST (Cont) o The modem DSR and CAR indicators should hear a carrier tone. should come on and you o The REMOTE USER indicator should stop blinking and stay on. o ·within 30 seconds, the modem should time-out and drop the line. You can then hang up the telephone. o The REMOTE USER indicator should begin blinking again. STEP 16 GENERIC SYSTEMS TEST In this step you will test for normal use of the system by the customer. o Set the RSC keyswitch to the USER PORT position. o The USER PORT indicator should come on. o Test the console terminal for normal operation by typing on the keyboard. o If the customer has a communications port application that uses the modem and telephone line, ask the local operator to: a. Check system comm port setup to make sure that either "modem" or "modem/perm" is set. If "no modem" is set, the test in b. and c. will fail. b. The modem DTR indicator (if it has one) should be on. c. Test comm port operation (by having a user log into the system through the modem). Log out before continuing to the next step. STEP 17 GENERIC SYSTEMS TEST In this step you will test the RSC LOCKOUT function. When the keyswitch is set to LOCKOUT, RSC does not allow remote access to the system. o Set the RSC keyswitch to the LOCKOUT position. o The LOCKOUT indicator should come on. o Test the console terminal for normal operation by typing on the keyboard. 1-18 VAX/PC38N TEST STEP 16 VAX CONSOLE PRINTER TEST In some circumstances the VAX Console printer may be enabled, but may not print. o Make sure that PRINTER is ENABLED and enter a Show Status command. o If the status report was printed on the LASO, you can skip to Step 17. If it was not, toggle the printer from ON LINE to OFF LINE to ON LINE. This should restore printer operation. o Enter another Show Status command and make sure that it is displayed on the VAX Console screen and also printed on the printer. STEP 17 VAX/PC38N / RSC PRELIMINARY TEST In this step you will do a preliminary test of the telephone line and modem before you ask the CSC to do their testing. o Make sure the modem has power. o Plug in the RSC power cord. The POWER indicator should come on. o Set the RSC keyswitch to should come on, blinking. o RSC transmits the message "(RSC 001) REMOTE PORT ENABLED" which should be printed on the (optional) hardcopy terminal connected to RSC at Al. o The modem DTR indicator should come on. o Use a nearby telephone and dial the number of the telephone line that is connected to the modem. o The modem DSR and CAR indicators should hear a carrier tone. o The VAX Console and the LASO pr inter should display message "WARNING. REMOTE CONNECTION ESTABLISHED. o Within 30 seconds, the modem should time-out and drop the line. You can then hang up the telephone. REMOTE. 1-19 The should REMOTE indicator come on and you the GENERIC SYSTEMS TEST STEP 17 GENERIC SYSTEMS TEST (Cont) o The modem DTR indicator should be off. o Use a nearby telephone and dial the number of the telephone line that is connected to the modem. o You should hear a ring signal continuously, should not respond. o After about 20 seconds you can hang up the telephone. STEP 18 but the modem GENERIC SYSTEMS TEST Call the CSC and ask them to do remote testing to verify that the RSC installation is working correctly. Digital ships most modems with option settings that let the CSC connect to RSC. If they find some incompatibility, they may ask you to change option settings. NOTE There are no steps 19 through 21 in the Generic Systems Test procedure. Skip now to Step 22 on page 1-23. 1-20 VAX/PC38N TEST STEP 17 VAX/PC38N / RSC PRELIMINARY TEST (Cont) o The message "(RSC 001) CONNECTION LOST" should be printed on the (optional) hardcopy terminal connected to RSC at Al. o The DSR and CAR indicators should go off but the DTR indicator should remain on. The message "(RSC 001) REMOTE PORT ENABLED" should be printed on the (optional) hardcopy ~erminal connected to RSC at Al. o The VAX Console and the LASO printer should message "WARNING. REMOTE CONNECTION BROKEN. STEP 18 VAX/PC38N / display the RSC (REMOTE) CSC TEST Call the CSC and ask them to test system operation. You can watch the VAX Console screen or the LASO printer as the CSC does the testing. Some of the tests they will do are: NOTE Digital ships most modems with option settings that let the CSC connect to RSC. If they find some incompatibility, they may ask you to change option settings. o Dial in and make a logical connection. The VAX Console and the LASO printer should display the message "WARNING. REMOTE CONNECTION ESTABLISHED. o Enter the Show Status command and verify that the VAX Console has been set up for RSC operation. If there are configuration errors, the CSC can make the corrections remotely. o Enter the Set Terminal Program (SET TERM P) command then, at the Username prompt, log in using the assigned account user name and password. o Enter a DIR command for a basic communications test. o Read the LOGFILE for OPAO (SH Lat the<<< prompt) to determine that remote port I/O activity is being monitored. Do an RHM (Remote Hardware Monitoring) installation and an RFT (Remote File Transfer). o Note that Digital ships most modems with option settings that let the CSC connect to RSC. If they find some incompatibility, they may ask you to change option settings. 1-21 VAX/PC38N TEST STEP 19 VAX/PC38N / RSC REMOTE USER TEST If the VAX/PC38N system has a communications port, you will test it in Steps 19 and 20. Skip to Step 21 if there is no comm port. In this step you will test the RSC Remote User function. o Set the RSC Keyswitch to the REMOTE USER position. o The CSC will make a connection to the system using DDCMP protocol. (Note that RSC supplies DTR.) o The CSC will log in with P I/O access only. o They will verify that they can do an RFT then log out. STEP 20 VAX/PC38N / RSC USER PORT TEST In this step you will test the RSC User Port function. o Set the RSC Keyswitch to the User Port position. o The CSC will make a non-protocol connection to the system. (Note that the comm port software must supply DTR; make sure "modem" or modem/perm" is set) • o The CSC will log in to the system as a user, verify that they can do an RFT, then log out. STEP 21 VAX/PC38N / RSC LOCKOUT TEST In this step you will test to make sure the RSC does not allow remote access to the system through the RSC's modem port. o Set the RSC Keyswitch to the LOCKOUT position. o The LOCKOUT indicator should come on. o The modem DTR indicator should be off. o You can ask the CSC to attempt remote access or you can do it yourself. Use a nearby telephone and dial the number of the telephone line that is connected to the modem. o You should hear a ring signal, but the modem should not respond. After about 20 seconds you can hang up the phone. 1-22 STEP 22 ALL SYSTEMS TEST You can now return control of the system to the local operator. STEP 23 Give the RSC User Guide, EK-KCRSC-UG, to the appropriate customer representative and explain how the guide is to be used. Insert the second RSC User Guide, EK-KCRSC-SM Management Guide binder behind the "R/D" tab. into the Site STEP 24 Ask a customer-authorized representative to sign the Field Transaction Report Form, EN-01748-12. A copy of that form is provided in Figure 1-10. YOU HAVE COMPLETED THE INSTALLATION 1-23 mnmoamnTM REMOTE SERVICES CONSOLE - FIELD TRANSACTION REPORT (Use this form to report only one RSC transaction) CUSTOMER/SYSTEM IDENTIFICATION Company Addrsss City lip Code Stats Remote Services Console used on: ComJJuter Sy_stem T.1J!.!: 0 Serm_ Number: ACKNOWLEDGEMENT OF INITIAL RSC INSTALLATION I, the undersigned authorized representative of the company named above, acknowledge receipt of a Remote Services Console IMDS011. I recognize that this Remote Services Console is proprietary equipment of, and always remains the exclusive property o.f, Digital Equipment Corporation. I accept this Remote Services Console in confidence and agree not to remove or tamper with any part of it, nor to disclose or make any part of it available to a third party. I further acknowledge that I will allow Digital full and free access to replace or remove the Remote Services Console and to restore the system to its original configuration upon expiration of the system warranty or termination of the Digital Service Agreement. MDS01 Serial Number 0 ----------------------~--~----- Date ACKNOWLEDEMENT OF RSC REMOVAL BY DIGITAL I, the undersigned Digital representative, acknowledge receipt of a Remote Services Console unit removed from the customer system identified above. MOS01 Serial Number D --------------------------------- Date ACKNOWLEDGEMENT OF RSC UNIT EXCHANGE We, the undersigned representatives of Digital and of the company named above, acknowledge an exchange involving two Remote Services Consoles. MOS01 Removed - Serial Number MDS01 Installed - Serial Number ~--~--~------------------~----------~~--------~--- Date Date Digital Representative's Name (Printed) Digital Representative's Signature Customer Representative's Name ( P r i n t e d ) - - - - - - - - - - - - - - - - - - - - - - - - - - Title Customer's Representative's Signature EN·O 1748· 12·"8eO 17PG> Figure 1-10 WHITE • CUSTOMER Field Transaction Report 1-24 CANARY • BRANCH PINK • OOC 1.3 If REMOVING THE RSC UNIT you have not done an installation, go back and chapter so you will know what was done and why. read all of th~s STEP 1 Arrange with the customer for access to the system. Make sure there are no known problems which the customer might assume were caused by removing RSC. You will be changing I/O cable connections, but you will not need to shut down the system. NOTE If the customer's system is running, do not disconnect power to the RSC until you have disconnected the I/O cables. Spurious noise at the console terminal or CPU console port could disturb system operation. Leave ac power applied to the RSC unit as you do Steps 2 and 3. STEP 2 Disconnect the cables from RSC connectors Al and A2. Connect the BC22D cable from the CPU Console Terminal port to the Console Terminal. STEP 3 Disconnect the cables (if they are present) from RSC connectors Bl and B2. Use a BC22E or BC22F cable to connect the modem to the CPU comm port. STEP 4 Disconnect the RSC power cord. STEP 5 Have the customer test the console terminal (or the VAX 8800 console), and communications port (if implemented) for normaL operation. STEP 6 Prepare a Field Transaction Report form, signed both by the customer's representative and yourself. The customer's copy will be a receipt acknowledging that Digital has taken posession of the RSC unit. STEP 7 Pack the option components in a suitable shipping container. 1-25 CHAPTER 2 OPERATION 2.1 INTRODUCTION This chapter tells you how to use the the RSC for both the customer's normal operation and Digital's remote services delivery. The RSC unit operates continuously and needs no routine maintenance. There are no switches or adjustments inside the enclosure. When the RSC logic is not busy, it runs a self-test program to ensure reliable operation. 2.2 SUMMARY OF OPERATION This paragraph gives a summary of the steps you take to operate a system with an RSC. First, four tables summarize operator information such as system set up for: o Generic systems such as VAX-11/780, Table 2-1, o Table 2-2 will provide VAXcluster systems information, o VAX systems with PC38N consoles, Figure 2-1). Tables 2-3 and 2-4 (and Second, there are two figures that show the logical data paths for each of the RSC modes of operation (Figures 2-2 and 2-3) • Then the paragraphs that follow explanations of the summary steps. 2-1 provide more detailed Table 2-1 Generic Systems Operator Information REMOTE SERVICES CONSOLE (RSC) GENERIC SYSTEM POWER indicator must be ON, FAULT indicator must be OFF. The local terminal must be 8-Bit, No Parity operation. Set BAUD M switches to data rate as the modem. Set BAUD T switches to same data rate as the local console terminal. same set for REMOTE Keyswitch Position CPU LOCAL/REMOTE keyswitch must be set to LOCAL. REMOTE indicator blinks when the remote station is not logically connected. Remote station terminal or host system replaces the local console terminal. RSC gives the remote station control of the target system when the local opera tor sets the RSC keyswitch to REMOTE. RSC Local Copy forces console terminal to print a record of remote I/O activity. DDCMP Protocol is enabled data integrity. to ensure Terminal messages tell you about remote station activity and status. RSC disables the CPU Comm Port. When the RSC keyswitch is set to REMOTE, you can boot the system from the local console terminal only when the remote. station enables parallel control (GIVE). REMOTE USER Keyswitch Position CPU LOCAL/REMOTE keyswitch must be set to LOCAL. REMOTE USER indicator blinks when the remote station is not logically connected. Local console terminal normal. RSC can support a comm port, but does not require it. RSC al lows remote access to the operating system through the CPU Comm Port with DDCMP protocol. USER PORT Keyswitch Position Enable CPU Comm Port software for "Modem on"/"modern perm" if modem dial-in capability is required. RSC is transparent. All system operation is normal. operation is System operation is normal. LOCKOUT Keyswitch Position RSC disables all remote access through its modem port. No remote port. access through System operation is normal. 2-2 RSC modem Table 2-2 VAXcluster Operator Information THIS PAGE IS RESERVED FOR VAXcluster INFORMATION WHICH WAS NOT AVAILABLE PRIOR TO THE PUBLICATION DATE OF THIS MANUAL 2-3 Table 2-3 Local VAX/PC38N Console Operator Information REMOTE SERVICES CONSOLE (RSC) VAX/PC38N SYSTEM POWER indicator must be ON, FAULT indicator must be OFF. Set BAUD M switches to same data rate as the modem. Set BAUD T switches to same data rate as the remote port. REMOTE Keyswitch Position Enable Remote User (EN R U) and/or Disable Remote Console (DIS R C) if the remote station is to have only PI/O user mode access. This is the traditional Remote Disable mode. REMOTE indicator blinks when the remote station is not logically connected. RSC gives the remote station control of the target system when the local operator enables remote access. DDCMP protocol is enabled to ensure data integrity. RSC Local Copy is redundant with VAX/PC38N if optional print/display terminal is connected to RSC at Al. Enable Remote Console (EN R C) enables CI/O and PI/O. Remote station can disable remote console to do RHM as a user (cannot re-enable it remotely). Disable Remote Modem (DIS R M) (RSC controls the modem). Note that the modem is not actually disabled; see VAX Console user documentation. Enable Remote Monitoring (EN R MON) to display remote station I/O activity at the VAX Console. Enable Printer (EN P) (VAX Console LASO) for hardcopy of remote station I/O activity. Remote Carrier status will be re_ported. REMOTE USER Keyswitch Position VAX Console operation is normal. REMOTE USER indicator blinks when the remote station is not logically connected. If the CPU comm port is implemented, the remote station has access to VMS, not the VAX Console. RSC allows remote access to VMS through the CPU comm port with DDCMP protocol. RSC can support a comm port, but does not re_g_uire it. USER PORT Keyswitch Position RSC is transparent. All system operation is normal. If the CPU comm port is implemented, the remote station has access to VMS without protocol. Enable CPU Comm Port software for "Modem on"/ "modem perm" if modem dial-in ca~ability is reguired. LOCKOUT Keyswitch Position No RSC modem port remote access. RSC disables all remote access through its modem port. System operation is normal otherwise. 2-4 Table 2-4 Remote Station (Host) Commands to VAX/PC38N COMMAND IN P I/O MODE ( $ PROMPT) IN C I/O MODE (>>> PROMPT) FUNCTION ENABLE OR DISABLE REMOTE MONITORING (EN R MON) (DIS R MON) Yes Yes Enable to display remote station I/O activity on the VAX Console screen. ENABLE OR DISABLE LOCAL COPY (COPY ON) (COPY OFF) Yes Yes Enables/disables optional display/printer if one is. connected to RSC at Al. (Enable for customer record of remote station I/O activity.) ENABLE LOCAL PRINTER DISABLE LOCAL PRINTER ( EN P) (DIS P) No No Yes No Enables the local printer (LASO connected to VAX Console printer port) to provide a hardcopy record of remote station I/O activity. (!) Remote station can SEND a message to the target system operator with no return message expected. Yes (!) Yes ( ! ) An exclamation mark ( ! ) preceding the message causes the message to be printed/displayed at the VAX Console and prevents it being seen by VMS. (!) Remote Station and local operator can TALK to each other at their terminals. (!) required as noted Yes (!) Yes Two-way. Two-way, above. OPAO and the Remote Station are at the >>> prompt. ENABLE OR DISABLE LOCAL VAX CONSOLE (OPAO) (EN LO C) (DIS LO C) No GIVE Existing GIVE function (parallel control) replaced by ENABLE LOCAL CONSOLE command. Yes 2-5 Disable prevents local operator interrupting remote operations. Enable gives parallel control. >>>SH S Printer ENABLED, ONLINE. Remote Carrier:ABSENT. emote user:ENABLED; console:ENABLED; modem:ENABLED; monitoring:ENABLED Program Mode settings: LOCAL=OPAO REMOTE=OPA(4 or 5) (These are Remote User, Remote Console, Remote Modem, and Remote Monitoring in Table 2-3. Note that Remote Carrier will be PRESENT when a remote logical connection is established.) Figure 2-1 Typical Printout For VAX/PC38N Console "Show Status" 2-6 REMOTE SERVICES CONSOLE COMM PORT -= = = KEYSWITCH MODEM I CPU CONSOLE TERMINAL PORT JD 11 REMOTE STATION 11 11 CONSOLE TERMINAL ====~ REMOTE SERVICES CONSOLE COMM PORT KEYSWITCH ---MICRO PROCESSOR MODEM CPU CONSOLE TERMINAL 111 ,,..._"'lAt PORT D REMO fE STATION LOCKOUT CONSOLE TERMINAL KEYSWITCH POSITION INDICATOR FUNCTION • REMOTE Blinks until RSC makes a logical connection to . the remote station, then It stays on. Remote station is logically connected as console terminal. DDCMP protocol is enabled to ensure data integrity. The comm port is logically disconnected. • LOCKOUT Shows that keyswitch is in LOCKOUT position. No remote access through RSC modem port. Console terminal operation is normal. Figure 2~2 Keyswitch Positions REMOTE and LOCKOUT 2-7 REMOTE SERVICES CONSOLE ! COMM PORT - KEYSWITCH c::J c ,,. MODEM CPU c D CONSOLE TERMINAL PORT REMOrE STATION CONSOLE TERMINAL REMOTE SERVICES CONSOLE COMM PORT. MODEM CPU KEYSWITCH CONSOLE TERMINAL PORT REMOTE STATION CONSOLE TERMINAL KEYSWITCH POSITION INDICATOR FUNCTION • USER PORT Shows that keyswitch is in USER PORT position. RSC is transparent. Console terminal operation is normal. Comm port and modem operation ore normal (no protocol). B,links until RSC makes a logical connection to the remote station, then it stays on. Remote station can access comm port with protocol. Console terminal operation is normal. '• • REMOTE USER Figure 2-3 Keyswitch Positions USER PORT and REMOTE USER 2-8 Table 2-5 Other Switches and Indicators +--------------------------------------------------------------------+ I SWITCH I INDICATOR I FUNCTION I +--------------------+-------------------+---------------------------+ LOCAL COPY Shows that the Forces the local console I keyswitch is set to REMOTE and the LOCAL COPY switch is ON. terminal or other print/ display terminal to print or display a record of all remote console I/O activity. +--------------------+-------------------+---------------------------+ DATA RATE SWITCHES There is no Used to set RSC interfaces indicator. to same data rates as local console terminal and modem. +--------------------+-------------------+---------------------------+ There is no power POWER - (Green) Shows that AC power is switch; RSC runs continuously. ON. +--------------------+-------------------+---------------------------+ FAULT - (Red) Shows RSC failure if it stays on after the onesecond self-test at I power up. I +--------------------+-------------------+---------------------------+ 2.3 POWER INDICATOR The POWER indicator comes on when the RSC unit is plugged in; there is no power switch. The indicator tells you that the RSC unit has ac power applied. 2.4 FAULT INDICATOR The FAULT indicator comes on when the RSC unit is plugged in. It stays on for about one second to show that the RSC power-up self-test is running. When the test is finished and there is no fault, the indicator goes off. If the test finds a fault the indicator stays on. The RSC logic runs a self-test program continuously when the unit is not busy and turns on the FAULT indicator if it finds a fault. 2-9 2.5 DATA RATE SWITCHES Since RSC is a data path switch, it must operate at the same data rate as the I/O devices that are connected to it. RSC has front panel switches for setting the data rate of each of its two paired interfaces ( 4 ports). There are three switches labeled BAUD T and three labeled BAUD M. Figure 2-4 shows you how to set the switches for data rates of 300, 1200, 2400, 4800, and 9600 b/s. 1 2 3 n BAUD T 1 2 BAUD M 3 1 2 ( f ( II ( I7 3 (1 I/ SET RSC DATA RATE SWITCHES TO THE SAME DATA RATE AS THE CONSOLE TERMINAL (BAUD T) ANO THE MODEM (BAUD Mt. Figure 2-4 Data Rate Switches Il n ..c::L Il I l Il ..c::L l l n _o_ .J:J.. .c:::::L ..c::::J... ...c::L.. IN _CJ.. ouTil 300 1200 2400 4800 9600 For example, if the console terminal is operating at 9600 b/s, you must set the BAUD T data rate switches to 9600. The chart shows that the three switches must be latched in. If the modem is operating a 1200 b/s, you set the BAUD M data rate switches to 1200 b/s also, switch 1 latched in, switches 2 and 3 out. +-----------------------------------------------------~---------+ VAX/PC38N NOTE The VAX Console Remote Port is not a traditional console terminal port; it is a modern control port. Set the BAUD T switches to the same rate as the VAX Console Remote Port. 2.6 KEYSWITCH The keyswitch controls the RSC's modes of operation. Figures 2-2 and 2-3 show the logical data paths for each keyswitch position. An operator can control remote access to the customer's system, either with or without protocol, or can prevent all remote access through the RSC modem port. By removing the key from the switch (only in the LOCKOUT and USER PORT positions), the operator can prevent anyone without a key from changing the setting, giving an added level of security. 2-10 There is an indicator for each of the four positions of the keyswitch. The indicator comes on to show the keyswitch setting. The two remote indicators blink to show RSC remote access status as explained in the following paragraphs. 2.6.l REMOTE The local operator sets the keyswitch to REMOTE to give a remote station (terminal or host) control of the system. DDCMP protocol is enabled to ensure data integrity. RSC logically connects the remote station to function as the system console terminal. Al 1 functions normally done by the local console terminal can be done from the remote station. The local console terminal can be enabled by either the remote operator or local operator to print a record of remote console terminal I/O activity (Paragraph 2.8). The local keyboard is normally disabled to prevent interruption of remote operation but it is enabled when the remote station invokes Talk or Parallel Control mode. The REMOTE indicator comes on, blinking, when the keyswitch is turned to the REMOTE position. The blinking shows that the RSC logic is enabled and waiting for a remote logical connection. The console message (RSC 001) REMOTE PORT EN~.. BLED is printed on the cons o 1 e term i n a 1 ( Par a graph 2•7) • When the connect i on is established, the indicator stops blinking (it stays on). +---------------------------------------------------------------+ VAX/PC38N NOTE I If, after the remote station connection is established, the operator disables the VAX Console Remote Port, all efforts made at the console keyboard to re-enable the port and establish the logical connection again will be unsuccessful. Both the telephone connection and the modem will appear to be normal. The remote station must break, then re-make the connection after the VAX Console Remote Port has been re-enabled. I I +---------------------------------------------------------------+ 2.6.2 LOCKOUT The local operator can set the keyswitch to LOCKOUT (Figure 2-2) to prevent all remote access to the system through the RSC modern port. The local console terminal operates normally, but the comm port is logically disabled by RSC. The Lockout function may be a security requirement for a customer's system. If the keyswi tch Lockout function is working correctly, the modem's DTR signal is 2-11 inhibited and the LOCKOUT indicator comes on. If the keyswitch is set to LOCKOUT and the indicator does NOT come on, RSC design provides two levels of security: FIRST - it warns the operator remote access may be possible. that there is a fault and SECOND - the RSC logic defaults to USER PORT functionality which means any possible remote access will be limited to the CPU comm port with no access to the console terminal port. 2.6.3 USER PORT The local operator can disable remote protocol access to the system by setting the keyswitch to USER PORT (Figure 2-3). A LED indicator comes on to show this keyswitch position. With the keyswitch set to USER PORT, RSC is logically transparent and the local console terminal functions normally. When a communications port application is using the modem and telephone line, that operation is normal also (no protocol). 2.6.4 REMOTE USER The local operator sets the keyswi tch to REMOTE USER to let a remote station, using DDCMP protocol, log in to the system through the communications port. Note that local console terminal operation is normal (Figure 2-3). The REMOTE USER indicator comes on, blinking, when the keyswitch is turned to the REMOTE USER position. The blinking shows that the RSC logic is enabled and waiting for a remote logical connection. When the connection is established, the indicator stops blinking (it stays on). 2.7 CONSOLE TERMINAL MESSAGES RSC logic senses changes in remote access status and transmits messages that can be displayed or printed on the local console terminal. These messages tell the local operator when the remote station is making or breaking connection to the system. The messages appear only when the RSC keyswitch is set to the REMOTE position. In VAXclusters and VAX/PC38N systems, hardcopy terminals for this purpose are optional and may not be present to display or print these messages. 2-12 o (RSC 001) REMOTE PORT ENABLED This message is transmitted by RSC immediately after the keyswitch is turned to the REMOTE position. Unless the RSC TERMINAL DATA RATE switches are set to match the data rate of the local console terminal, the message will be garbled. (See Paragraph 2.8.) o (RSC 001) CONNECTION LOST This message is transmitted when the remote station terminates the telephone connection (hangs up). This message can be transmitted also as a result of a hardware failure or loose connection, for example. +---------------------------------------------------------------+ VAX/PC38N NOTE The VAX Console can display similar messages for the local operator when it is set up to detect a remote connection. +---------------------------------------------------------------+ 2.8 LOCAL COPY SWITCH When the local operator sets the RSC keyswitch to REMOTE, control of the system is given to a remote station. When the remote station is the CSC, the host software usually disables the target system console terminal. The customer may want to display or print a record of what the remote station does while it has control of the system. A record of that I/O activity is displayed or printed when: o The CSC invokes Local Copy mode (in RSC firmware), or o The local operator sets the RSC LOCAL COPY switch ON, and o A hardcopy or display terminal has been provided purpose. for that To summarize RSC's Local Copy functionality: o The local operator can force local copy by setting the RSC LOCAL COPY hardware switch. o The CSC can invoke (force) copy mode in RSC firmware. o Neither the hardware switch nor firmware override the other to disable local copy. local copy by setting the local setting can The LOCAL COPY switch and indicator are logically functional only when the keyswitch is set to REMOTE. 2-13 +--------------------------------------------------~------------+ VAX/PC38N NOTE Table 2-4 shows that there are three possible configurations for.t~rminals and/or displays to monitor remote station I/O I act1v1ty. +---------------------------------------------------------------+ 2-14 CHAPTER 3 TROUBLESHOOTING 3.1 INTRODUCTION This chapter tells you how to do basic testing of the telephone line, the modem, and the RSC unit. The field maintenance philosophy for RSC is unit swapping. If you have any problem the CSC can help you solve it. 3.2 TROUBLESHOOTING PROCEDURES The following paragraphs describe the procedures for RSC troubleshooting. You can do some of them, the CSC must do the others. Each procedure stands alone and should be passed successfully before going on to the next procedure. Table 3-1 is a troubleshooting aid. 3.3 CABLE TEST AND RSC BYPASS If you cannot successfully complete a test and you suspect that either a cable or the RSC unit itself is at fault, cable patching is a "quick check". In this procedure you disconnect cables only at the RSC unit. o If you want to bypass RSC and test console terminal operation, disconnect (at connector Al on the the RSC unit) the cable that goes to the console terminal. Disconnect (from RSC connector A2) the cable that goes to the CPU console terminal port. Plug the two cable connectors into each other. Console terminal operation should be normal with RSC out of the circuit. o If you want to bypass RSC and test the communications port, disconnect (from RSC connector Bl) the cable that goes to the communications port. Disconnect (from RSC connector B2) the cable that goes to the modem. Plug the two cable connectors into each other. Communications port operation should be normal with RSC out of the circuit. o If the RSC unit should fail, or you want to temporarily, do both of the previous steps. 3-1 remove it 3.4 POWER-UP TEST When the RSC unit passes this test, the basic unit is working correctly. Note that the I/O interfaces are not tested until Paragraph 3. 5. · The tests can be made with, or with out, I/O cables connected. 1. Set the RSC keyswitch to USER PORT. 2. Check to make sure that the RSC voltage select switch is set for the correct operating voltage. 3. Check to make sure that the fuse is good and is the correct value for the operating voltage. 4. Plug in the ac power cord. 5. If the POWER indicator does not come on, make sure there is ac power at the receptacle. If there is, check the power cord and the RSC fuse (again) • (Installation Step 3 has information that may help you when you are replacing a fuse.) If the ac supply, the power cord, and the fuse are good, (and there is still no RSC power) replace the RSC unit. 6. If the POWER should also. indicator comes on, the USER PORT indicator 7. The FAULT indicator should come on. It should stay on for about one second while the RSC power-up self-test runs. 8. If the RSC unit is working correctly, the FAULT indicator should go out. If the self-test finds a fault, the FAULT indicator will stay on. 9. If the FAULT indicator stays on, replace the unit. +----~---~------~----------~------------------------------------+ VAX/PC38N NOTE If you are working with a VAX/PC38N system, see Tables 2-3 and 2~4 for system set-up information which may help as you continue RSC testing. I +---------------------------------------------------------------+ 3-2 3.5 USER PORT TEST If you can successfully complete this procedure, the RSC console terminal and communications port I/O interfaces are working correctly. Note that RSC can support a comm port but does not require one for its operation. 1. Set the keyswitch to USER PORT. 2. Type on the console terminal keyboard and make sure operation is normal. RSC should be completely transparent. 3. If the customer has a comm port application, ask the local operator to log in through the the communications port, telephone line, and modem. This tests not only the RSC communications port I/O interface, but also the telephone line and modem. If this test passes, you can skip Paragraph 3. 6. 3.6 TELEPHONE LINE AND MODEM TEST 1. Change the keyswitch to REMOTE USER or REMOTE. 2. Check the modem to make sure the DTR indicator (if there is one) is on. 3. From a nearby telephone, dial line connected to the modem. the number of the telephone 4. You should hear a ring signal and the modem ring should come on. indicator 5. You should hear a carrier signal. Whistle into the phone at about the same frequency as the carrier signal. The modem DSR indicator should come on. 6. Hang up. The modem indicators should go off. 3.7 REMOTE USER TEST You must have the CSC do this test. It verifies access through the CPU communications port. remote protocol 1. Set the keyswitch to REMOTE USER. 2 • The REMOTE US ER ind i cat or remote access is enabled logical connection). 3. Type on the console operation is normal. should come on, bl inking (RSC and it is waiting to make a terminal 3-3 keyboard and make sure that 4. When the CSC makes connection, the should stop blinking and stay on. REMOTE USER indicator 5. The CSC will log into the system as a user. 3.8 REMOTE TEST You must have the CSC do this test. It verifies remote protocol access that allows a remote station to take control of the system. 1. Set the keyswitch to REMOTE. 2. The ;REMOTE indicator should come on, bl inking (RSC remote access is enabled and it is waiting to make a logical connection) • 3. The console terminal should print REMOTE PORT ENABLED". the message 4. Check to disabled. terminal see that the console "(RSC keyboard 001) is 5. When the CSC completes the telephone connection, the REMOTE indicator stops blinking (it stays on). 6. The CSC tests RSC for correct remote operation. 7. When the CSC hangs up, the console terminal prints the message "(RSC 001) CONNECTION LOST". 8. The REMOTE indicator should start blinking. 9. After a 4 second delay, the console terminal the message "(RSC 001) REMOTE PORT ENABLED". 3-4 should print Table 3-1 Troubleshooting Chart +----------------------+------------------------------------------+ I SYMPTOM I CAUSE OR ACTION I +----------------------+------------------------------------------+ POWER indicator does Check ac at receptacle and power cord. I not come on. Check fuse. I +----------------------+------------------------------------------+ FAULT indicator The RSC unit has failed. To bypass a stays on. faulty RSC unit, disconnect console terminal cables from Al and A2 and patch them together. Disconnect modem/comm port cables from Bl and B2 and patch them together. +----------------------+------------------------------------------+ I LOCKOUT indicator If the RSC Lockout logic fails, the I does not come on. indicator is turned off and RSC defaults to USER PORT mode. +----------------------+------------------------------------------+ No remote access. The CPU LOCAL/REMOTE switch must be set to LOCAL for RSC operation. For VAX/PC38N - If the VAX Console remote port is disabled after the remote station is connected, it cannot be re-enabled except by having the remote station break, then re-make the connection. I I +----------------------+------------------------------------------+ I No USER PORT access I Check modem power and connections. and no DTR signal at modem. CPU Comm Port software may be set to "no modem". +----------------------+------------------------------------------+ Printout garbled or CSC has set Local Copy mode or GIVE characters printed twice on terminal. mode and the RSC LOCAL COPY switch is also set. This problem has been resolved in MDSOl units with revisions of Bl or greater (See Page 2-13) +----------------------+------------------------------------------+ Printout garbled. Terminal must be set for 8-bit, no parity. +----------------------+------------------------------------------+ CPU will not boot. If the RSC keyswitch is set to REMOTE, the local console terminal is disabled. I +----------------------+------------------------------------------+ 3-5 APPENDIX A USER GUIDE INTRODUCTION This appendix is a copy of the RSC User Guide, EK-KCRSC-UG, that is shipped with the RSC unit. The guide is printed on heavy paper stock and is intended for use by the customer. A second RSC User Guide, EK-KCRSC-SM, is also shipped with the RSC unit. That guide has the same information, but it is printed on plain paper and is to be inserted into the Site Management Guide binder behind the "R/D" tab. A-1 EK-KCRSC-UG-002 . Remote Services Console User Guide A-2 LOGICAL DATA PATHS FOR EACH KEVSWITCH POSITION REMOTE SE ~VICES MODEM CPU CONSOLE TERMINAL ll~--.JI...........,____.___..__. PORT REMOTE STATION CONSOLE 111~~11TERMINAL RE'vlOTE SERVICES CONSOLE ....------. M1CRc1 PROCESSOR CPU KOSV\ilTCH REIVlO'E sr.:.7•0111 LOCKOUT CONSOLE TERMllll.l.L KEYSWITCH POSITION INDICATOR FUNCTION • REMOTE Blinks until RSC makes a logical connection to the remote station, then it stays on. Remote station is logically connected as console terminal. DDCMP protocol is enabled to ensure data integrity. The comm port is logically disconnected. • REMOTE USER Blinks until RSC makes a logical connection to the remote station, then it stays on. Remote station can access comm port with protocol. Console terminal operation is normal. • USER PORT Shows that keyswitch is in USER PORT position. RSC is transparent. Console terminal operation is normal. Comm port and modem operation are normal (no protocol). • LOCKOUT Shows that keyswitch is in LOCKOUT position. No remote access through RSC modem port. Console terminal operation is normal. A-3 LOGICAL DATA PATHS FOR EACH KEYSWITCH POSITION REMOTE SERVICES CONSOLE C.\1v1 Pr}Rr uv--'-1111--1 '.10DE:\/I ·~~~~;..L;L 11~-"IUPQRT D RE!V10'E STAT;ON CONSOLE 11._,_"""-'11-' TEq:\/llNAL REMOTE SERVICES CONSOLE C:OMM 11 V---".11 t--Z:='-i PORT :\/!ODEM •:CJ<\;SOLE TERMINAL l l V - " ' ' J I PORT REMOTE STATION CONSOLE ,,._,_...... , rERMINAL THE OTHER SWITCHES AND INDICATORS SWITCH INDICATOR FUNCTION LOCAL COPY SWITCH Shows that keyswitch is set to REMOTE and local copy switch is ON. Forces local console terminal to print a record of remote console terminal 1/0 activity. DATA RATE SWITCHES (BAUD T AND BAUD M) No indicator These switches set RSC interfaces to same data rates as local console terminal and modem. No power switch POWER - Green Shows that cc power is on. FAULT- Red Shows RSC fault if on after one second self-test at power-up. - A-4 REMOTE SERVICES CONSOLE USER GUIDE OPERATION 1. Make sure RSC Data Rate Switches are set correctly.. 2. Set RSC keyswitch to select mode of operation. 3. Check the RSC indicators •POWER- on • FAULT - off • KEYSWITCH position indicator - on • LOCAL COPY - on if the RSC keyswitch is set to remote and the LOCAL COPY switch is latched in. 4. For VAX/PC38N or VAX Cluster - You may have to connect and/or enable a hardcopy terminal if you want to use LOCAL COPY. 5. For VAX Cluster - You will have to change the Z Box (VCS Disable) switch setting to disconnect the target CPU from the cluster and enable a hardcopy terminal. TO SET DATA RATE SWITCHES RSC must operate at the same data rate as the console terminal and modem that are connected to it. The BAUD T and BAUD M switch settings determine the data rates of those RSC interfaces. BAUD T [ BAUD M z z z z z I l I I I 0 SET RSC DATA RATE SWITCHES Il Il Il ...CJ... Ili _o_ _o_ ..0.. . I l Il_l Ill ..CJ... 300 1200 2400 4800 TO THE SAME DATA RATE AS THE CONSOLE TERMINAL ,BAUD T1 ANO ..c:J.. THE MOOE\1 BAUO Mi 1 IN A-5 ..c:L .J::L ..CJ... OUT _o_ 9600 RSC OPERATION NOTES • The key can be removed from the RSC keyswltch when it Is set to LOCKOUT or USER PORT. • The CPU LOCAL/REMOTE switch must be set to LOCAL or LOCAL DISABLE (not a remote position) for RSC operation. • System setup must specify "modem" or "modem/perm" to enable RSC remote operation. • The CPU will not boot if the RSC keyswitch is set to REMOTE. The console terminal is disabled. • The LOCAL COPY indicator comes on only when the RSC keyswltch is set to REMOTE because the local copy logic is not functional in the other keyswitch positions. • If the lockout logic fails, the LOCKOUT indicator will not come on and RSC will default to USER PORT mode. • To bypass a faulty RSC unit, unplug console terminal cables from A1 and Ki. and patch them together. The 81/82 cables can be patched to connect the comm port to the modem. • For VAX/PC38N - If, after the remote station connection is established, the operator disables the console remote port, all efforts made at the console keyboard to re-enable the port and re-establish the logical connection again will be unsuccessful. Both the telephone connection and modem operation will appear to be normal. The remote station must break, then re-make the connection after the console remote port has been re-enabled. A-6 INDEX A AC power, 1-2 Accessibility of RSC, 1-3 Adapter, for VAX/PC38N, 1-1, 1-3, 1-14 B Baud M/T, see Data Rate switches BC22D, 1-11 BC22E/BC22F cable, 1-3 installation, 1-14 Booting, 2-2, 3-5 Bypassing a failed RSC, vii, 3-1 E EIA connectors, 1-14, 3-1 F Fault indicator, 2-9, 3-2 FCC modem data, 1-2 Features, vi Field Transaction Report, 1-18 Fuse, 1-4 G Generic installation overview, 1-8 c I Cable, BC22D, 1-7, 1-11 BC22E/BC22F, 1-3 configuration table, 1-14 installation, 1-7, 1-11 RSC configuration, 1-12 test, 3-1 type required, 1-3 Certifications, vii Comm port, 1-2 test, 3-3 "Connection Lost message", 1-16, 2-13 Console terminal, 1-7, 2-2 messages, 1-16, 2-12 Console terminal port, 1-14, 1-15 CPU LOCAL/REMOTE switch, 2-2 Installation, DDC testing, 1-18 FCC modem data, 1-2 kit contents, 1-3 modem, 1-1, 1-14 procedure, 1-3 removing, 1-20 site preparation, 1-1 K Key, vii, 2-10 Keyswitch, operation, 2-2, 2-4, 2-7, 2-10 testing, 1-16, 1-17 Kit contents, 1-3 D L Data Rate switches, vii, 1-15, 2-2, 2-4, 2-9 DDC/RDC installation test, 1-18 user account, 1-7 DDCMP protocol, vi, 2-2, 2-4 DF03/DF112 modem, 1-2 Documentation, viii RSC User Guide, A-1 Site Management Guide, A-1 DSR/DTR, 1-16 Label, RSC front, 1-5 Local copy, 2-9, 2-13 Lockout Keyswitch position, operation, 2-2, 2-4, 2-7, 2-11 testing, 1-17 Logical connection, 2-7, 2-11 I-1 INDEX s M Messages, .console terminal, 1-16, 2-12 Modem on/perm, no modem 1-17, 2-2, 2-4 data rates, 1-15 DF03/DF112, 1-2 test, 1-15, 3-3 type required, 1-1 Self-test, 1-6, 2-1, 2-9 Site Management Guide, A-1 Site preparation, 1-1 Switch, data rate, vii, 1-15, 2-9 keyswitch, 2-10 local copy, 2-13 voltage select, 1-4 N T /no modem, 1-17, 2-2, 2-4 Talk, 2-5 Telephone line, 1-1 test, 3-3 Terminal set-up, 1-15, 2-2 Transaction Report Form, 1-18 Troubleshooting, 3-5 0 Operator Information generic systems, 2-2 VAX/PC38N I 2-4 u p User account, 1-7 User Guide, 1-18, A-1 User port keyswitch position operation, 2-2, 2-4, 2-8, 2-12 testing, 1-17, 3-3 PC38N - See VAX/PC38N Power indicator, 2-9 Protocol, DDCMP, vi, 2-2, 2-4 R v Remote keyswitch position, operation, 2-2, 2-4, 2-7, 2-11 testing, 1-15, 3-4 Remote diagnosis, vii "Remote port enabled" message, 1-16, 2-13 Remote services delivery, vi Remote User keyswitch position, operation, 2-2, 2-4, 2-8, 2-12 testing, 1-16, 3-3 Removing RSC, 1-20 VAXcluster information will be added in the next revision. VAX/PC38N, adapter, 1-1, 1-3, 1-14 BAUD T switches, 1-15, 2-10 console, 2-4 commands, 2-4 remote port, 1-15, 2-4 installation overview, 1-9 operator information, 2-4, 2-5 Remote Port, 2-11 Voltage Select switch, 1-4 I-2 Digital Equipment Corporation• Stow, MA 01775
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies