Digital PDFs
Documents
Guest
Register
Log In
MISC-6840B79D
January 1981
6 pages
Original
0.8MB
view
download
Document:
Dual RK07 Disk-Based VAX-11/780 System Configuration
Order Number:
MISC-6840B79D
Revision:
Pages:
6
Original Filename:
OCR Text
Dual RK07 Disk-Based VAX-11/780 System Configuration Effective: January 1981 Configuration Guidelines This VAX-11/780 packaged system Is configured with 512K bytes of ECC MOS memory, an RK711 UNIBUS control[er with two top loading RK07 cartridge disk drives for a total of 56 megabytes of on-line storage, and an LA 120 DECwriter Ill console terminal. UNIBUS I ~ 2 3 .... 5 The CPU cabinet in this system houses a UNIBUS Mounting Frame which contains the RK711 controller, one DZ11-A asynchronous multiplexer for connection of eight EIA communication lines, and mounting space for UNIBUS options. RK711 CONTROLLER FOR RK07 DISK DRIVE 6 7 ~t2 8 9 Please note that there may be no substitution made for the LA 120 console terminal In this packaged system. Also note that It is not advisable to use a video terminal as the console device because there are cases where diagnostics and system software messages are longer than the number of lines available on the screen. In these cases, parts of the error messages would be lost as they scrolled off the top of the screen. J_ TERMINATOR v UNIBl!_~ I3 2 SUs MOUNTING SPACE r4 Memory The CPU cabinet in this system has predesignated space available for an additional 3,584K bytes of ECC MOS, 16K chip memory for a total of four megabytes in the basic CPU cabinet. Additional memory may be ordered in any of the combinations noted in the VAX SYSTEMS AND OPTIONS SUMMARY. UNIBUS MOUNTING FRAME UNIBUS expansion in this system is also governed by several other configuring considerations: UNIBUS Expansion One DW780 UNIBUS Adapter (UBA) Is mounted in predesignated CPU cabinet space. The system can run as many UNIBUS options (listed in the VAX Systems & Options Summary) from the UBA as will mount into the available backplane space in the UNIBUS Mounting Frame (see diagram and Table I), within the power and bus load limits of the UNIBUS. First, there is a system limit of one distribution panel. The DZ11-A which comes with this system includes a controller for eight asynchronous EIA lines and a 16-line distribution panel (to which one DZ11-B may be added for control of an additional eight EIA lines). Therefore, any additional distribution panels (e.g., for the DMR11, DZ11, CS11, LPA11-K and lab options, CS11) require the add-on UNIBUS Options Cabinet, H9602-DF(DH), for mounting. To expand beyond the limifs of the UNIBUS Mounting Frame, an UNIBUS Options Cabinet, H9602-DF(DH), can be ordered (see back cover). This cabinet, which Includes an 861-C(B) power control, provides space for two additional BA 11-K boxes and three more DZ11 distribution panels. Second, expansion is limited by space available In the UNIBUS 1/0 Panel (see diagram). This panel serves as the connection point between control modules mounted in the UNIBUS Mounting Frame and their associated external devices. Dual RK07 Disk-Based VAX-11 /780 System Configuration UNIBUS MOUNTING FRA E li: I i ! .. ~ ~ ~! IrI ~ SPACE FOR FLOAT.PT POWER COOLING 512K BYTE MEMORY AND CONTROLLER I CPU ~en (EXPANSION SPACE FOR AN ADDITIONAL 3,SMK BYTES) i wz :f 00 ~0 ~il ~ POWER SUf'PLY FOR CPU SUP.PLY ~~ POWER SUPPLY FOR CPU 1 POWER SUPPLY FOR MEMORY COOLING POWER SUPPL HOR ~ ~ ~ lJi 0 RK07 DISK DRIVE AK07 DISK DRIVE • UNIBUS MOUNTING COOLING TIME-OF-YEAR CLOCK BATTERY MEMORY BATTERY BACKUP (OPTION) ] ~r====-==,,..-~~~-'--'--'--,.,..,~~----, I 1 DZ11 ·A ASYNCHRONOUS 8-LINE MULTIPLEXER 4 DIST PAN I MICA~°:PUTER : CONSOLE I F~~~ 11 lL:~NT~_J : ~~~e~;N~~x : (REAR MOUNTED) L l I RX01 FLOPPY DISK SUBSYSTEM J VAX-11 /780 CPU CABINET DEDICATED DISK CABINETS The system's RK711 UNIBUS controller and the first RK07 disk drive, as well as the LA 120 console terminal have been preconnected on this panel. In addition, there is reserved space for the remote diagnosis line, routing and strain relief for local DMC11 cables, and six Connector Spaces. There are also two predesignated spaces for power supplies in the CPU cabinet: one for the power supply Included with the Floating Point Accelerator option and a second for the H7112 memory battery backup option. In this dual RK07 system configuration, there is adequate power available @+5V in the UNIBUS Mounting Frame for mounting any UNIBUS options (as listed in the VAX Systems & Options Summary). There are 17 bus loads available for UNIBUS options expansion. (See Table I) Options requiring Connector Spaces are listed below in Table X, along with the number of spaces each requires. CONNECTOR SPACES OPTION 1 Line Printers (LP11, LA 11, LPR11) 1 Card Readers (CR11, CME11) 1 DMC11-DA,-FA Remote Lines (local DMC11s have dedicated space for cables - see diagram) 2 DR11-B Interface 1 DUP11 Interface STRAIN RELIEF FOR LOCAL DMC11 CABLES CONSOLE TERMINAL RESERVED FOR RD LINE CONNECTOR SPACE CONNECTOR SPACE CONNECTOR SPACE A BC06K-9F cable and an H7004-B filter is needed for each option which requires a Connector Space (CS). Cables and filters are provided as appropriate for options which are ordered at the same time as the packaged system. However, an additional cable and filter must be purchased for each Connector Space required by any field installed options. CONNECTOR SPACE CONNECTOR SPACE Power Supplies CONNECTOR SPACE This VAX-11 /780 configuration includes four power supplies which provide power for the CPU, UNIBUS Adapter, optional WCS (KU780), the first four megabytes of ECC MOS memory, and options mounted in the UNIBUS Mounting Frame. MODEL SV-AXHHV-CA(CD) UNIBUS 1/0 PANEL MEMORY MASS STORAGE EXPANSION SPACE POWER AVAILABLE Amps@+5V BUS LOADS AVAILABLE 512Kb ECCMOS Dual RK07s CPU Reserved space for: NIA 17 3,584Kb memory FP780 KU780 H7112 UNIBUS MOUNTING FRAME SU 1-2: 1 Hex slot 1 Quad slot Adequate Power For Any UNIBUS SU3-4: Table I 2SUs Options Mounted Please note that the Information below describes the configuration of the SV-AXHHV packaged system when It Is upgraded with the VAX-11/780 System Upgrade Option, H9604BA(BB). VAX-11/780 System Upgrade Option, H9604-BA(BB) 1/0 Adapters (UNIBUS and MASSBUS) A field installed System Upgrade Option is available for this VAX11/780 packaged system. It includes one H9602-DF(DH) UNIBUS Expansion Cabinet with power control, plus a BA 11-KE(KF) expansion mounting box and one 0011-DK expansion backplane. The upgrade involves the transfer of all UNIBUS options in the CPU Cabinet's UNIBUS Mounting Frame to the UNIBUS Expansion Cabinet. One DW780 UNIBUS Adapter (UBA) Is mounted in predesignated CPU cabinet space. MASSBUS Adapters (MBA) and additional UNIBUS Adapters can be mounted In the Option Panel Spaces available in the CPU Cabinet and the CPU Expansion Cabinet, H9602-HA/HB. Each MBA and each additional UBA requires one Option Panel Space. VAX-111780 systems can accommodate up to four UNIBUS Adapters AND four MASSBUS Adapters. The space occupied by the UNIBUS Mounting Frame is converted to two Option Panel Spaces and the UNIBUS 1/0 Panel is eliminated. In addition, it becomes possible to order the CPU Expansion Cabinet, H9602-HA(HB), which provides four additional Option Panel Spaces. Once the system has been upgraded, the Option Panel Spaces in the CPU Cabinet and the CPU Expansion Cabinet can be used to mount MASSBUS Adapters (MBA), additional UNIBUS Adapters (UBA), a second memory controller (CPU Expansion Cabinet only), Multiport Memory port interfaces, and/or the DR780 general purpose interface. Memory (Local and Shared) The system can run as many UNIBUS options (listed in the VAX Systems & Options Summary) from a UBA as will mount into the allowable backplanes (within the the power and bus load limits of the UNIBUS). One BA11-K expansion box must be ordered for each UBA which is added to a VAX-11/780 system, in order to mount options which are to be connected to additional UNIBUSes. An MBA is needed when adding high-performance MASSBUS devices such as RM80, RM05, RM03, RP06, TE16, TU45, or TU77. These devices should be ordered as REM80, REMOS, REM03, REP06, TEE16, TEU45, or TEU77 respectively, each of which includes the mass storage unit, its controller, a MASSBUS Adapter, and the power su r that MBA. For expansion beyond four megabytes to a maximum of eight megabytes of local memory, an H9602-HA(HB) CPU Expansion Cabinet can be ordered. An additional four megabytes of memory with control (one MS780-C plus combinations of MS780-D expansion memory) can be mounted in this cabinet. The MS780-C controller requires two Option Panel Spaces (OPS) in the CPU Expansion Cabinet. Each MBA can run up to eight disk drives, OR eight TE16 or TU45 tape drives and seven disk drives OR four TU77 tape drives and seven disk drives on its MASSBUS. Physical memory can also be expanded using the MA 780 Multiport (shared) Memory Option. Two of these options can be added to a VAX-11/780 system. Each MA780 holds up to 2 megabytes of ECC MOS memory. The DR780 is a general-purpose interface which can be used to connect customer-designed devices to a V AX-111780. Also, two DR780s can be used to connect two VAX-111780 systems. Maximum VAX-11 /780 configurations will therefore support up to 12 megabytes of ECC MOS memory. The MA780 Multiport Memory option is connected to a VAX11 /780 via port interfaces (MA780-C). One MA780-C can be mounted in the basic CPU cabinet. If two MA780 subsystems are to be connected, an Option Panel Space In the CPU cabinet or the CPU Expansion Cabinet is required. The MA780 cabinet is always positioned adjacent to either the CPU cabinet or the CPU Expansion Cabinet. DR780 High-Performance Channel Interface The DR780 requires one Option Panel Space in a CPU Expansion Cabinet, H9602-HA(HB). It includes the interface logic, power supply, and 25 ft. of cable. There is a limit of one DR780 perVAX111780 system and the DR780 cannot be configured on systems which already include the MA780 Multlport Memory. The cable from the user device to the DR780 can be up to 80 ft. in length. Table II lists necessary information on expansion space, plus available power and bus loads for configuring add-on equipment to this upgraded VAX-111780 packaged system. Upgraded Dual AKO? Disk-Based VAX-11 /780 Con figuration SPACE FOR OIST.#2 (REAR MOUNTED) w 0 ~ <r w >;!; ~ 0 "'0z 0 ."' z ~~ w >- 0 ;: <r 'l 0 ~ ~~ > w > ..... f2 ffi fil <r "'<r2. "iii"' <r " 512K BYTE MEMORY ANO CONTROLLER "'" (EXPANSION SPACE FOR AN ADDITIONAL "'z "'l ffi fil PANEL SPACE FOR < "< CPU BA11-K#2 3,584K BYTES) RK07 DISK DRIVE ~ <r RK07 DISK DRIVE " SPACE FOR FLOAT.PT. POWER SUPPLY " . ~ Cl ;:: < POWER SUPPLY FOR CPU POWER SUPPLY FOR CPU POWER SUPPLY FOR MEMORY SPACE FOR POWER SUPPLY BA11-K COOLING COOLING TIME-OF-YEAR CLOCK BATTERY MEMORY BATTERY BACKUP (OPTION) RX01 FLOPPY DISK SUBSYSTEM 11 /03 MICROCOMPUTER CONSOLE VAX-11/780 CPU CABINET UNIBUS EXPANSION CABINET DEDICATED DISK CABINETS 1 Asynchronous Multiplexers (Programmed 1/0) UNIBUS There are two kinds of asynchronous multiplexers available on VAX-11 /780 systems, one for 20mA current loop operation and one for EIA/CCITT. Each of these is available In 8- or 16-line units. 2 3 4 5 6 7 ,."'..... RK711 CONTROLLER FOR RK07 DISK DRIVE The table indicates the correct options to order based upon the number and type of terminals or lines to be used. Note that a OZ11-A, which includes a controller for eight EIA lines and a 16line distribution panel, is standard with every packaged system. 2 8 9 Quantities of EIA lines and 20mA lines can be mixed, but only in groups of eight on different distribution panels. The first 8 lines of either option includes its own 16-line distribution panel which is prewired. So, for example, if 8 lines of EIA and 8 lines of 20mA are desired, two different distribution panels are required. To expand to more than 48 lines, an H9602-0F(OH) UNIBUS Options Cabinet can be added. DZll-A•ASYNCHRONOUS 8-LINE EIA MULTIPLEXER 3 i--~~~~~~~~~~~~~~~~~--io 1--~~~~~~~~~~~~~~~~~---lg i--~~~~~~~~~~~~~~~~~--io ,. 4 NUMBER LINES 5 1 SU EIA 20 milliampere loop 1-8 DZ11-A (incl.) DZ11-C 9-16 DZ11-B DZ11-F 17-24 OZ11-E DZ11-F + DZ11-C 25-32 DZ11-E + DZ11-B DZ11-F + DZ11-F 33-40 DZ11-E + DZ11-E DZ11-F + DZ11-F +DZ11-C 41-48 DZ11-E + DZ11-E +DZ11-B OZ11-F + DZ11-F + DZ11-F BA11-KE(KF) EXTENSION MOUNTING BOX The information in this table should only be used for an initial VAX-11/780 system. UNIBUS Expansion Cabinet The UNIBUS Expansion Cabinet which comes with the upgrade kit contains one BA 11-K expansion mounting box, and one 0011-0K expansion backplane mounting unit. The UNIBUS Expansion Cabinet can house a maxlmum of two BA 11-K expansion mounting boxes and provides space for up to three OZ11 distribution panels. Each distribution panel is capable of handling up to 16 lines for either EIA or 20mA terminals for a possible total of 48 asynchronous lines. Power Supplies The upgraded VAX-11 /780 configuration includes three power supplies which provide power for the CPU, UNIBUS Adapter, optional WCS (KU780), the first four megabytes of ECC MOS memory. There are also two predesignated spaces for power supplies in the CPU cabinet: one for the power supply included with the Floating Point Accelerator option and a second for the H7112 memory battery backup option. To expand beyond the limits of the UNIBUS Expansion Cabinet, an UNIBUS Options Cabinet, H9602-0F(OH). can be ordered (see back cover). This cabinet,. which includes an 861-C(B) power control, provides space for two additional BA 11-K boxes and three more OZ11 distribution panels. The optional VAX-11/780 CPU Expansion Cabinet, H9602HA(HB), also includes space for two power supplies to accommodate additional memory and 1/0 adapters plus space for the power supply included with the memory battery backup option. The illustration above shows where the RK711 disk controller, the 0011-0K, and the OZ11-A mount in the BA 11-K. Note that the RK711 and 0011-0K each occupy 2 SUs of space and provide a total of 8 Hex slots and 3 Quad slots of additional mounting space. In this upgraded dual RK07 system configuration, there is a total of 34.5 amps of power @+SV and 17 bus loads available for UNIBUS expansion. SYSTEM CODE MEMORY MASS STORAGE EXPANSION SPACE Upgraded 512KB ECCMOS DualRK07s BA11·K: SU 1-2: 2Hexslots 1 Quad slot SV-AXHHV POWER AVAILABLE Amps@+SV 17 13.0 6Hexslots 2Quadslots 1SU 21.5 CPU: FP780-AA(AB) KU780 3,584K bytes memory 20PS H7112-A(B) NIA SU3-5: Table II BUS LOADS AVAILABLE NIA VACTI 780 Environmental Considerations SPACE FOR DtST.#5 (REAR MOUNTED) VAX-11 /780 systems, as well as other DIGIT AL products, are designed to perform while exposed to a variety of environmental conditions. DIGITAL recommends the following environmental operating specifications for the computer facility for maximum reliability: • • • • Temperature: 18°C to 24°C (65°F to 75°F). Temperature rate of change: 2°C/hr.(3.6°F/hr.). Relative humidity: 40% to 60% (non-condensing). Humidity rate of change: 2%/hr. PANEL SPACE FOR BA11·K#4 c SPACE FOR DIST.#6 p u 1----~--~-~~--11/ All VAX-11 /780 system environments should be fully evaluated by a Field Service representative to ensure proper performance. OIST.#4 (REAR MOUNTED) ~ J--S-P-AC-E-,...-S-P-AC_E__,""""',.,.,,..,,..,...,,.I B ~g~ER ~g~ER SUPPLY SUPPLY Add-On UNIBUS Options Cabinet H9602-DF(DH) PANEL SPACE FOR BA11·K#3 COOLING For UNIBUS expansion beyond the limits of the system's UNIBUS Expansion Cabinet, the UNIBUS Options Cabinet, H9602-DF(DH), may be ordered. This single-width, high-boy cabinet, which includes an 861-C(B) power control, can accept two additional expansion mounting boxes (shown in the diagram to the far right as BA11-K #3 & BA11-K #4), and three more distribution panels. MEMORY BATTERY BACKUP OPTION POWER CONTROL POWER CONTROL VAX-111780 CPU EXPANSION CABINET H9602-HA(HB) ADD-ON UNIBUS OPTIONS CABINET H9602-DF(DH) Please note that expansion backplane mounting units (0011 s), the BA 11-Ks, and the distribution panels are not included and must be ordered separately for use in this add-on UNIBUS Options Cabinet. VAX-11 /780 CPU Expansion Cabinet H9602-HA(HB) A single-width, high-boy cabinet, referred to as the H9602HA(HB) CPU Expansion Cabinet. This cabinet includes four Option Panel Spaces which may be used to mount additional memory, port interfaces for the Multiport Memory option, 110 adapters, and the DR780 interface option. These subsystems can be configured as required up to the maximum number of each device supported by the VAX/VMS operating system and within the available mounting space in each system. Refer to the VAX Systems and Options Summary for more detailed information on the mounting requirements of the various subsystems. The CPU Expansion Cabinet also includes space for the power supplies for these options and for one H7112-A(B) memory battery backup option. 1 UNIBUS 2 ~ l 3 1 4 5 0 6 ~ 0' 7 8 "' 2 9 . TO~~\!&~,,.. v I ~ 1 SU The H9602-HA(HB) is always positioned adjacent to the main CPU cabinet. Expansion Mounting Box Diagram BA 11-KE( KF) When an additional BA 11-K is mounted in an UNIBUS cabinet, use the diagram to configure the option modules. For your reference, a 0011-DK has been included in this diagram. However, please note that the BA 11-K does not include 0011-CK or 0011-DK expansion backplane mounting units. Therefore, DD11s must be added to your CONFIGURING WORKSHEET as separate line items to convert system unit space to module slots. As shown, the BA 11-K box provides mounting space for five system units. SUs 1-2 together, and SUs 3-5 together, each have 25.0 amps of power available @+5V. I- 3 t4 lSU I- 1 SU BAil-KE (KF) EXTENSION MOUNTING BOX • For information only - not included In the BA 11-KE(KF). 5
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies