F-68 PDP INSTALLATION MANUAL DIGITAL EQUIPMENT CORPORATION PHYSICAL CHARACTERISTICS The PDP-6 Programmed Data Processor is a high-speed, stored-program, digital computer co nstructed of modular solid -state circuits. Each PDP-6 is tailormade to specific customer needs by selecting th e proper equipment from a list of cen tral processor and input-output options . A typical system installation could include one or more of the units described below. In most cases syst em units are housed instandard Digital ca binets. However, some pieces of equipment, especially those that require writing surfaces or tables for accessory equipment, have specially designed cabinets; others which require only one or two racks of cabinet space are mounted in existing cabinets whenever possible. Note that dimensions in the table are for complete units, standing alone. If desired, standard cabinets may be attached to one another by removing end panels. Over-all dimensions are then reduced by the width of the removed panels (11,4 inches per side) ; weight is reduced by 45 pounds per panel. ARITHMETIC PROCESSOR 166 FAST MEMORY 162 5 I-LSEC CORE MEMORY 161 2 I-LSEC CORE MEMORY 163 BjC INCREMENTAL CRT DISPLAY 346 CARD PUNCH 460A CARD PUNCH 460B CARD READER 461A Weight (I b) 1300 400 800 800 700 910 1525 200 Dimensions (in_) Width Depth Height 81 V, 44 V. 69 v. 22 'A 42 27'116 69 V. 42 42 51 69V. 44 V, 28 53 73 27 V, 47 30 17 50 See Comment 36 36 27 ~6 69V. 27 ~6 69v. Service Clearance (in.) Front Rear 66 14v. 8~ 8~ 8~ 8~ 14'l'. 14v. 14v. 36 See Comment 36 36 Heat Dissipation (Btujhr) 9900 2150 3300 4950 5900 9420 9420 495 Current (A) Nominal Surge 25 40 5.5 8 8.5 13 17 15 20 22 22 10 - 1.3 7 Power Dissipation (KW) 2.9 0.635 0.98 1.5 1.73 2.75 2.75 0.145 Standard Cabinets 4 1 2 2 2 0; See note 1 0; See note 1 0 ; See note 1 16 words O.4l-Lsec complete cycle . 16,384 words of 36 bits. 16,384 words of 36 bits. Table protrudes 19 V, in. in front. Type 346 includes incremental display and vector gen erator. Comments Table protrudes 35 in . front, 18 in. right hand side. Clearance is included above. - Side clearance 36 in. each side . Speed , 100 cards per minute. - 6% Side Speed, clearance 200 cards 36 in. per minute each side. I Speed, 300 cards per minute. Notes : 1. Additional control logic, consisting of one or two racks, is normally mounted in existing cabinets when space is available. 2 . Dimensions include size and weight of one standard cabinet. This cabinet is not required if space for four to six racks is available in existing cabinets. , ENVIRONMENTAL REQUIREMENTS POWER REQUIREMENTS The central processor and input-output devices operate satisfactorily under ordinary conditions of humidity, shock, and vibration in a 50 to 105°F temperature range. However, a 70 to 85°F temperature range and a 30% to 80% humidity range are recommended. Consult the system heat characteristics that follow in planning room air conditioning if required. Each unit of the PDP-6 system requires a separate source of 105- to 125-volt, 60-cycle, single-phase power. On special request, all equipment can be factory wired for 50-cycle and/or 220- to 250-volt power. The power source must maintain the nominal voltage within ± 10% under normal and transient load conditions. The electrical characteristics of individuaL units appear in the table below. DUAL MICROTAPE MICROTAPE CONTROL TRANSPORT 551 555 MAGNETIC TAPE CONTROL 516 MAGNETIC MAGNETIC TAPE TAPE TRANSPORT TRANSPORT 50 570 CARD READER 461B LINE PRINTER 646 LINE PRINTER 680 DATA CONTROL 136 750 1350 1500 233 255 65 281 600 850 48 29 50 56 30\4 52 to 57 56 30\4 52 to 57 22\4 27'A. 69\1, 22\4 27'A. 69\1, 19 17 \I. 12 22 \4 27'A. 69 \1. 22 \4 27'A. 69 \I. 32 \I, 32 ¥o 68 See Comment 24 26 8lA 14% 8lA 14v. 2\4 36 See Comment 24 26 - 8lA 14v. 18'116 14% 18y. 14% 4950 2710 3210 1200 1200 585 1564 2114 9800 - - - 17.4 3 5 3 5 1.5 3.2 4 6 8 12 - 1.45 1.56 2.06 0.345 0.345 0.172 0.460 0.62 2.9 0; See note 1 0; See note 1 0; See note 1 1; See note 2 1; See note 2 - 1; See note 2 1 - Speed, 800 cards per minute. Side clearance, 26 in. left, 30 in. right. Speed, 300 or 600 lines per minute. Side clearance, 26 in. left, 30 in . right. Speed, 1000 lines per minute. Controls up to six devices including two Type 551's and two Type 516's. Controls up to four Type 555 Dual Microtape Transports. Requires Type 136. 13 ,---. 13 Mounts in standard cabinet or on Type 166 Processor Console. Requires Type 551 and Type 136. Type 136 and one of Types 520 , 521 , or 522 Interface Logic required. Controls up to eight Digital or IBM transports. Requires Type 516 with Type 520 Interface and Type 136. 25 Requires Type 516 with Type 521 Interface and Type 136. 81 FAN (TYP) 4 ·.CABINETS f2' SWINGING PLENUM DOORS REMOVEABLE END PANE L S 14~8" CASTER SWIVEL RADIUS --t + + + + + + CABLE ACCESS (TYP) 4 CABINETS 27~6' '~ '4 Arithmetic Processor Type 162 " , 4r REMOVE A8LE - " '1-:;-1 - _ ", "\I / " > SWINGI NG DOORS (2) , , 'AN l r:; 4'" "- - ....... , ", ", , / \,' ..., '~J, - --, - " ,, ,>-- ,, /' / , I \ , " "", , \ \1 " LOAD POINT 4 .---...t~" END PANEL GO~· REMOVE ABlE '0 -- - , CASTERS (8) + ~ " 11 4 r----y 33fzR ~~~~ 27j6 " of' + } il 3.l - R 1 4~ + ~~~==~~~~ SCR EW PADS ( 2 ' _ ~ IS{ / / SWINGING DOORS SHORT ez) ..... /~--. - - - - SWING ING MAG- TAPE OOOR Standard Computer Cabinet 19f- +- + . 6t"+1t--l [NO PANEL .. -X' f , "' + t~ ' .. _ ,' __ 60'0"_ ----------- + I ~ - -/ J __~J+- '\ , "" , tr- CABLE ACCESS .. 27,' ~ .'• - -----.1 l Incremental CRT Display Type 346 .......-- SWINGING DOORS (2) ~ FOOT LEvELERS (4) / ___ 3fR _____ Plan views are scaled at Y2 inch per foot. The outlines of the various units may be traced in any desired arrangement to plan the installation layout. SWIVEL CASTEPS ( 2 ) ___ FILTER &. FAN (2) v '--- ---- _ _ ~IGID CASTERS (Z) Magnetic Tape Transport Type 570 SWINGING 0700R 5 OIA CUTOUT FOR CABLE GOING TO A( POWER 1 Lfil JLOAD POI """ in : - -- 0 - -, 5 6 II ~"""''----+~L--'-T -j ~ '1- ,~ -3 2"8 Card Reader Type 461A CAST E R SWivEL jlo\1 r 1 3" IIO~"1 I I r+ I I I I I I I I I I ! I I I tCASTERS I (4) + +: ~___---56"·---~.1 I I Line Printer Type 646 CABLING REQUIREMENTS All system power sources must be provided with 115-volt, 30-amp, Hubbel Twistlock, flush receptacles (or their equivalent) to mate with inputoutput equipment power cables. Fifty-wire shielded signal cables with Amphenol 115-114P male connectors at both ends interconnect input-output equipment and input-output control units. Any special equipment used with the system must have Amphenol 115-1145 female connectors and 1391 shells to accept signal cables. The central processor and input-output control units are interconnected by four 18-conductor, coaxial cables. Bus cables have Amphenol 1-900309 female connectors at both ends. Special input-output controls must be equipped with Methode MD6225 male connectors to receive the bus cables. Unless otherwise specified, power cables are supplied in. 20-foot lengths, permanently wired at one end to individual units. Signal cables come unattached in 25-foot lengths; bus cables are made to order. Power and signal cables measure 11/16 and 13/16 of an inch in diameter, respectively. Bus cables measure Ya by 2% inches. Cables enter cabinets through bottom ports. Cabling for a typical system installation is shown below. TO OTHER DEV ICES TYPICAL DEVICE , < ( ~----------~~------------~ LINE PRINTER CONTROL LINE PRINTER 646* TO OTHER MEMORIES MAGNETIC TAPE TRANSPORT 570 CORE MEMORY MAGNETIC TAPE TRANSPORT 570 I TO MORE T RANSPORTS 1 MAGNETIC TAPE CONTROL 5161521 * < 163 DUAL MICROTAPE TRANSPORT DUAL MICROTAPE TRANSPORT * 555* 555 1 1 TO MORE TRANSPOR T S MICROTAPE CONTROL 55 1 * MEMORY BUS (4 CABLES) 1 FAST MEMORY 162 DATA CONTROL 136 I ARITHMETIC PROCESSOR /\ ~--~ (2) * 110 BUS (4 CABLES) ~----------------~ 166 . · : Gl- ___ I I"",, I ' ~r' A·I-tf TELETYPE 1---==--' 626 ~ _ _. . * USUALLY NOT MOUNTED IN A SEPARATE CABINET ONE POWER CORD SERVES AL L DEVIC ES IN A CABINET DIGITAL'S SERVICE POLICY Digital's reputation for reliability owes a great deal to rigid quality control and customer field service. Before delivery all Digital products are thoroughly tested by trained check-out teams. Each module and every piece of accessory equipment is subjected to rigorous tests, many of them conducted by specially designed, automatic check-out devices. Computers and special systems are checked electrically and logically by numerous programmed routines. During system checkout, customers are invited to visit the Maynard manufacturing facility to inspect and become familiar with the equipment. Computer customers may also send personnel to free instruction courses in computer operation and maintenance either in Maynard or at the Los Angeles sales office. Digital's engineers are available during installation and test for assistance or consultation. Further technical assistance in the field is provided by home office design engineers or branch office application engineers in New York, Washington, Pittsburgh, Chicago, Los Angeles, San Francisco, Ottawa, Sydney (Australia), Reading (U. K.), and Munich. EQUIPMENT CORPORATION MAYNARD , MASSACHUSE TT S Los Angeles . Pa lo Alto · Pittsburgh Washington, D. C . • Parsippany , N . J. Chicago . An n Arbor, Mich .· Carleton Place, Ontario • Munich, Germany Reading, England · Sydney, Australia 150 67 PRINTED IN U,S,A. 25-9 / 64
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies