Digital PDFs
Documents
Guest
Register
Log In
EK-DS10V-UR-B01
2000
10 pages
Original
94.0kB
view
download
Document:
AlphaServer for OpenVMS VS10 User Reference Card
Order Number:
EK-DS10V-UR
Revision:
B01
Pages:
10
Original Filename:
OCR Text
EK–DS10V–UR. B01 ALPHASTATION XP900 USER REFERENCE CARD This document is intended as a quick reference for the user. Additional information can be found in the AlphaStation XP900 Console Reference guide, EK-DS10V-CR. Overview • Environmental Specifications • Mechanical Specifications • Electrical Specifications • Front Buttons and LEDs • Ethernet LEDs • Beep Codes • PCI Slots • Memory Configuration • SRM Console Commands • Remote Management Console (RMC) Commands • Acoustics WARNING: To prevent injury, access is limited to persons who have appropriate technical training and experience. Such persons are expected to understand the hazards of working within this equipment and take measures to minimize danger to themselves or others. CPU modules and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before touching any module. Wear an antistatic wrist strap when working on this system. © Compaq Computer Corporation 1999. All rights reserved. 1 To reduce the risk of electrical shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Disconnect power by unplugging the power cord from the electrical outlet or the workstation. Environmental Specifications Storage temperature range –40º C to 66º C (–40º F to 151º F) Operating temperature range 10º C to 40º C (50º F to 104º F) Max. rate of change 11º C (20º F) per hour Storage humidity range (noncondensing) 10% to 90% relative humidity; maximum wet bulb 65º C (149º F) Operating humidity range (noncondensing) 10% to 90% relative humidity (without removable media) or 20% to 80% relative humidity (with removable media); maximum wet bulb 2º C (36º F) Nonoperating–4867 m (16,000 ft.); Operating—2400 m (8,000 ft.) Max. altitude Nonoperating shock 30 G, 25 ms halfsine 2 Mechanical Specifications Leave ventilation room around the system. PK1015 Height 13 cm (5 in.) Width 43 cm (17 in.) Depth 46 cm (18 in.) Weight 14.5 kg (32 lb) Electrical Specifications • Check your power supply setting. • Secure the power cord by turning the safety latch clockwise over the power cord. Secure the latch by tightening it with a screwdriver. 115V 230V PK1047a 3 Front Buttons and LEDs The LEDs are located in the lower right corner on the front of the system. PK1043a Symbol Function Halt button. Suspends the operating system and returns control to the SRM console. Environmental amber LED. On indicates Temperature or Fan LEDs are on. Flashes when operating system invokes it as an alert. Temperature amber LED. On indicates internal temperature exceeds operating conditions. The system shuts down 30 seconds after this LED lights. Fan amber LED. On indicates at least one of the three fans in the system has failed. The system shuts down 30 seconds after this LED lights. Disk Activity green LED. Flashes when internal system disks are accessed. Power Present green LED. On when power is present in the system. Power button. Push in to start the system and connect power. Push again to remove power and stop the system. 4 Ethernet LEDs The Ethernet LEDs are on the back of the system, lower right corner. Link Speed/Activity PK1050-99 LED Link Speed Activity Meaning Steady green indicates Ethernet connection Green for Ethernet speed of 100 Amber for Ethernet speed of 10 LED blinks with Ethernet activity Beep Codes The speaker in the front of the system reports errors using a series of beeps. Beeps 1-2-3 4 6 7 Meaning Valid firmware image not found Valid ROM header not found Memory error (or bad checksum) detected DIMMs in a memory bank do not match 5 PCI Slots The SRM console command show config displays PCI information. PCI Slot 4 64 Bit PCI Slot 3 64 Bit PCI Slot 2 64 Bit PCI Slot 1 32 Bit PK1045-99 Memory Configuration The SRM console command show memory displays the memory configuration. DIMM BANKS 1 0 1 0 DIMM CONFIGURATION RULES: • Always fill at least one bank (0 or 1). • Use the same two DIMMs within a bank (size and vendor). PK1046a 6 SRM Console Commands alphabios Loads and starts the AlphaBIOS console. boot Loads and starts the operating system. clear envar Resets an environment variable to its default value. clear password continue Sets the password to zero. Resumes program execution. crash Forces a crash dump at the operating system level. deposit Writes data to the specified address. edit examine help Invokes the console line editor on a RAM file or on the nvram file (power-up script). Displays the contents of a memory location, register, or device. Displays information about the specified console command. initialize Resets the system to a known state. lfu Runs the Loadable Firmware Update Utility. login Turns off secure mode, enabling access to all SRM console commands during the current session. more Displays a file one screen at a time. 7 SRM Console Commands (continued) prcache Utility that initializes and displays status of the optional PCI NVRAM device. set envar Sets or modifies the value of an environment variable. set host Connects to an MSCP DUP server on a DSSI device. set password Sets the console password for the first time or changes an existing password. set secure Enables secure mode without requiring a restart of the console. show envar Displays the state of the specified environment variable. show config Displays the configuration at the last system initialization. show cpu Displays the state of each processor in the system. show device Displays a list of controllers and their devices in the system. show memory Displays memory module information. show pal Displays the version of the privileged architecture library code (PALcode). show power Displays information about the power supplies, system fans, CPU fans, and temperature. show version Displays the version of the console program. stop Halts the specified processor. (Same as halt.) test Runs firmware diagnostics for the system. 8 Remote Management Console (RMC) Commands alert_clr Clears alert flag, stopping dial-out alert cycle. alert_dis Disables the dial-out alert function. alert_ena Enables the dial-out alert function. disable Disables remote access to the modem port. enable Enables remote access to the modem port. halt Halts the system. haltin Causes a halt assertion. haltout Terminates a halt assertion created with haltin. hangup Terminates the modem connection. help or ? Displays the list of commands. poweroff Turns off power. poweron Turns on power. quit Exits console mode and returns to system console port. reset Resets the system. Emulates pressing the Reset button. setesc Changes the escape sequence for invoking command mode. setpass Changes the modem access password. status Displays system status and sensors. 9 Acoustics Preliminary declared values per ISO 9296 and ISO 7779: LWAd, B LpAm, dBA (bystander positions) with 0xHDD with RZ1DF Idle Operate Idle Operate 5.3 5.4 5.3 5.5 45 46 45 48 Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA. Schallemissionswerte — Vorläufige Werteangaben nach ISO 9296 und ISO 7779/DIN EN27779: mit 0xHDD mit RZ1DF Schalleistungspegel LWad, B Schalldruckpege LpAm, dBA (Zuschauerpositionen) Leerlauf Betrieb Leerlauf Betrieb 5,3 5,4 5,3 5,5 45 46 45 48 Aktuelle Werte für speziele Ausrüstungsstufen sind uber die Compaq Computer Vertretungen erhältelich. 1 B = 10 dBA. For More Information • AlphaStation XP900 Console Reference (EK-DS10V-CR) • AlphaStation XP900 Quick Setup (EK-DS10V-CP) • Using a Web browser, follow links to the appropriate documentation from the URL: http://www.compaq.com/products/workstations 10
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies