Digital PDFs
Documents
Guest
Register
Log In
EK-DS10V-UR-A01
2000
4 pages
Original
0.1MB
view
download
Document:
AlphaServer for OpenVMS VS10 User Reference Card
Order Number:
EK-DS10V-UR
Revision:
A01
Pages:
4
Original Filename:
OCR Text
EK–DS10V–UR. A01 ALPHASERVER FOR OPENVMS VS10 USER REFERENCE CARD This document is intended as a quick reference for the user. Additional information can be found in the AlphaServer DS10 / AlphaStation VS10 Console Reference guide, EK-DS10S-CR. Overview • Environmental Specifications • Mechanical Specifications • Electrical Specifications • Front Buttons and LEDs • Ethernet LEDs • • Memory Configuration SRM Console Commands • Remote Management Console (RMC) Commands • Acoustics Environmental Specifications Storage temperature range –40º C to 66º C (–40º F to 151º F) Operating temperature range 10º C to 40º C (50º F to 104º F) Max. rate of change 11º C (20º F) per hour Storage humidity range (noncondensing) 10% to 90% relative humidity; maximum wet bulb 65º C (149º F) Operating humidity range (noncondensing) 10% to 90% relative humidity (without removable media) or 20% to 80% relative humidity (with removable media); maximum wet bulb 2º C (36º F) Nonoperating–4867 m (16,000 ft.); Operating—2400 m (8,000 ft.) Max. altitude Nonoperating shock PK1015 Height 13 cm (5 in.) Width 43 cm (17 in.) Depth 46 cm (18 in.) Weight 14.5 kg (32 lb) Electrical Specifications • Check your power supply setting. • Secure the power cord by turning the safety latch clockwise over the power cord. Secure the latch by tightening it with a screwdriver. 115V Beep Codes PCI Slots Mechanical Specifications Leave ventilation room around the system. 230V • • To reduce the risk of electrical shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Disconnect power by unplugging the power cord from the electrical outlet or the workstation. 30 G, 25 ms halfsine WARNING: To prevent injury, access is limited to persons who have appropriate technical training and experience. Such persons are expected to understand the hazards of working within this equipment and take measures to minimize danger to themselves or others. CPU modules and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before touching any module. Wear an antistatic wrist strap when working on this system. PK1047a © Digital Equipment Corporation 1999. All rights reserved. 1 Front Buttons and LEDs The LEDs are located in the lower right corner on the front of the system. Ethernet LEDs The Ethernet LEDs are on the back of the system, lower right corner. PCI Slots The SRM console command show config displays PCI information. Link PK1043a Symbol Function Halt button. Suspends the operating system and returns control to the SRM console. Environmental amber LED. On indicates Temperature or Fan LEDs are on. Flashes when operating system invokes it as an alert. Temperature amber LED. On indicates internal temperature exceeds operating conditions. The system shuts down 30 seconds after this LED lights. Fan amber LED. On indicates at least one of the three fans in the system has failed. The system shuts down 30 seconds after this LED lights. Disk Activity green LED. Flashes when internal system disks are accessed. Power Present green LED. On when power is present in the system. Speed/Activity PCI Slot 4 64 Bit PCI Slot 3 64 Bit PCI Slot 2 64 Bit PCI Slot 1 PK1050-99 LED Link Speed Activity Meaning Steady green indicates Ethernet connection Green for Ethernet speed of 100 Amber for Ethernet speed of 10 LED blinks with Ethernet activity 32 Bit PK1045-99 Memory Configuration The SRM console command show memory displays the memory configuration. DIMM BANKS Beep Codes The speaker in the front of the system reports errors using a series of beeps. Beeps 1-2-3 4 6 7 Meaning Valid firmware image not found Valid ROM header not found Memory error (or bad checksum) detected DIMMs in a memory bank do not match Power button. Push in to start the system and connect power. Push again to remove power and stop the system. 2 1 0 1 0 DIMM CONFIGURATION RULES: • Always fill at least one bank (0 or 1). • Use the same two DIMMs within a bank (size and vendor). PK1046a SRM Console Commands alphabios Loads and starts the AlphaBIOS console. boot Loads and starts the operating system. clear envar Resets an environment variable to its default value. clear password continue crash deposit edit examine help Sets the password to zero. Resumes program execution. Forces a crash dump at the operating system level. Invokes the console line editor on a RAM file or on the nvram file (power-up script). Displays the contents of a memory location, register, or device. Displays information about the specified console command. Resets the system to a known state. lfu Runs the Loadable Firmware Update Utility. more prcache set host Turns off secure mode, enabling access to all SRM console commands during the current session. Connects to an MSCP DUP server on a DSSI device. Sets the console password for the first time or changes an existing password. set secure Enables secure mode without requiring a restart of the console. show envar Displays the state of the specified environment variable. alert_clr Clears alert flag, stopping dial-out alert cycle. alert_dis Disables the dial-out alert function. alert_ena Enables the dial-out alert function. disable Disables remote access to the modem port. enable Enables remote access to the modem port. halt Halts the server. haltin Causes a halt assertion. show config Displays the configuration at the last system initialization. haltout Terminates a halt assertion created with haltin. show cpu Displays the state of each processor in the system. hangup Terminates the modem connection. help or ? Displays the list of commands. show device Displays a list of controllers and their devices in the system. poweroff Turns off power. show memory Displays memory module information. poweron Turns on power. show pal Displays the version of the privileged architecture library code (PALcode). quit Exits console mode and returns to system console port. show power Displays information about the power supplies, system fans, CPU fans, and temperature. reset Resets the server. Emulates pressing the Reset button. setesc Displays the version of the console program. Changes the escape sequence for invoking command mode. setpass Changes the modem access password. status Displays system status and sensors. show version Displays a file one screen at a time. Utility that initializes and displays status of the optional PCI NVRAM device. Sets or modifies the value of an environment variable. set password Writes data to the specified address. initialize login set envar Remote Management Console (RMC) Commands stop Halts the specified processor. (Same as halt.) test Runs firmware diagnostics for the system. 3 Acoustics Preliminary declared values per ISO 9296 and ISO 7779: LWAd, B LpAm, dBA (bystander positions) with 0xHDD with RZ1DF Idle Operate Idle Operate 5.3 5.4 5.3 5.5 45 46 45 48 Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA. Schallemissionswerte — Vorläufige Werteangaben nach ISO 9296 und ISO 7779/DIN EN27779: mit 0xHDD mit RZ1DF Schalleistungspegel LWad, B Schalldruckpege LpAm, dBA (Zuschauerpositionen) Leerlauf Betrieb Leerlauf Betrieb 5,3 5,4 5,3 5,5 45 46 45 48 Aktuelle Werte für speziele Ausrüstungsstufen sind uber die Compaq Computer Vertretungen erhältelich. 1 B = 10 dBA. For More Information • AlphaServer DS10 / AlphaStation VS10 Console Reference (EK-DS10S-CR) • AlphaStation VS10 Quick Setup (EK-DS10VCP) • Using a Web browser, follow links to the appropriate documentation from the URL: http://www.compaq.com/showroom/ 4
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies