Digital PDFs
Documents
Guest
Register
Log In
EK-DS10S-UR-C01
2000
4 pages
Original
0.2MB
view
download
Document:
AlphaServer DS10 AlphaStation DS10 User Reference Card
Order Number:
EK-DS10S-UR
Revision:
C01
Pages:
4
Original Filename:
OCR Text
EK–DS10S–UR. C01 ALPHASERVER DS10 ALPHASTATION DS10 USER REFERENCE CARD This document is intended as a quick reference for the user. Additional information can be found in the AlphaServer DS10 & DS10L / AlphaStation DS10 Console Reference guide, EK-DS10S-CR. Overview • Environmental Specifications To reduce the risk of electrical shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Disconnect power by unplugging the power cord from the electrical outlet or the workstation. Mechanical Specifications Leave ventilation room at the front and rear of the system. Environmental Specifications Storage temperature range –40º C to 66º C (–40º F to 151º F) Operating temperature range Max. rate of change Height 13 cm (5 in.) 10º C to 40º C (50º F to 104º F) Width 43 cm (17 in.) Depth 46 cm (18 in.) 11º C (20º F) per hour Weight 14.5 kg (32 lb) Storage humidity range (noncondensing) 10% to 90% relative humidity; maximum wet bulb 65º C (149º F) • • Front Buttons and LEDs Ethernet LEDs • • Beep Codes PCI Slots Operating humidity range (noncondensing) • • Memory Configuration Front Access Drives (some Models) 10% to 90% relative humidity (without removable media) or 20% to 80% relative humidity (with removable media); maximum wet bulb 2º C (36º F) Nonoperating–4867 m (16,000 ft.); Operating–2400 m (8,000 ft.) • • SRM Console Commands Remote Management Console (RMC) Commands • Acoustics Nonoperating shock Electrical Specifications • Check your power supply setting (some models). • Secure the power cord by turning the safety latch clockwise over the power cord. Secure the latch by tightening it with a screwdriver. 115V Mechanical Specifications Electrical Specifications 230V • • Max. altitude PK1015 30 G, 25 ms halfsine WARNING: To prevent injury, access is limited to persons who have appropriate technical training and experience. Such persons are expected to understand the hazards of working within this equipment and take measures to minimize danger to themselves or others. PK1047a CPU modules and memory modules have parts that operate at high temperatures. Wait 2 minutes after power is removed before touching any module. Wear an antistatic wrist strap when working on this system. © Compaq Computer Corporation 2001. 1 Front Buttons and LEDs The LEDs are located in the lower right corner on the front of the system. Ethernet LEDs The Ethernet LEDs are on the back of the system, lower right corner. PCI Slots The SRM console command show config displays PCI information. PCI Slot 4 64 Bit Link PCI Slot 3 64 Bit Speed/Activity PCI Slot 2 64 Bit PK1043a Symbol Function Halt button. Suspends the operating system and returns control to the SRM console. Environmental amber LED. On indicates Temperature or Fan LEDs are on. Flashes when operating system invokes it as an alert. Temperature amber LED. On indicates internal temperature exceeds operating conditions. The system shuts down 30 seconds after this LED lights. Fan amber LED. On indicates at least one of the three fans in the system has failed. The system shuts down 30 seconds after this LED lights. Disk Activity green LED. Flashes when internal system disks are accessed. PCI Slot 1 PK1050-99 LED Link Speed Activity Meaning Steady green indicates Ethernet connection Green for Ethernet speed of 100 Amber for Ethernet speed of 10 LED blinks with Ethernet activity Beep Codes The speaker in the front of the system reports errors using a series of beeps. Beeps 1-2-3 4 6 7 Meaning Valid firmware image not found Valid ROM header not found Memory error (or bad checksum) detected DIMMs in a memory bank do not match Power Present green LED. On when power is present in the system. Power button. Push in to start the system and connect power. Push again to remove power and stop the system. 2 32 Bit PK1045-99 Memory Configuration The SRM console command show memory displays the memory configuration. DIMM BANKS 1 0 1 0 DIMM CONFIGURATION RULES: • Always fill at least one bank (0 or 1). • Use the same two DIMMs within a bank (size and vendor). PK1046a Front Access Drives (Some Models) Front access disk drives are optional on some models. Follow these steps to remove a drive or a spacer panel from a front access bay. 1. 2. 3. 4. 5. 6. Ensure that the drive to be removed has been properly dismounted (via the operating system) before extracting it from the system. Push the tab on the left of the drive the extractor lever. X to disengage SRM Console Commands (continued) SRM Console Commands alphabios Loads and starts the AlphaBIOS console. boot Loads and starts the operating system. clear envar Resets an environment variable to its default value. clear password continue Sets the password to zero. Resumes program execution. crash Grasp the lever in the middle and pull it forward; this will cause it to disengage the drive from the flange on the right-hand side of the lever. Pull the drive forward out of the bay. Forces a crash dump at the operating system level. deposit Writes data to the specified address. If you need to remove a blank spacer panel, push the tabs toward each other and pull the spacer out. examine Y Z To replace the drive, slide it back into the bay, secure the latches, and remount it. 3 edit help Displays the contents of a memory location, register, or device. Displays information about the specified console command. initialize Resets the system to a known state. lfu Runs the Loadable Firmware Update Utility. login more 1 Invokes the console line editor on a RAM file or on the nvram file (power-up script). Turns off secure mode, enabling access to all SRM console commands during the current session. prcache Utility that initializes and displays status of the optional PCI NVRAM device. set envar Sets or modifies the value of an environment variable. set host Connects to an MSCP DUP server on a DSSI device. set password Sets the console password for the first time or changes an existing password. set secure Enables secure mode without requiring a restart of the console. show envar Displays the state of the specified environment variable. show config Displays the configuration at the last system initialization. show cpu Displays the state of each processor in the system. show device Displays a list of controllers and their devices in the system. show memory Displays memory module information. show pal Displays the version of the privileged architecture library code (PALcode). show power Displays information about the power supplies, system fans, CPU fans, and temperature. show version Displays the version of the console program. Displays a file one screen at a time. 2 MR0020 SCSI jumpers for front access drives are located on the back of the front access drive cage. Default for the drive located in the bottom slot is 0; default for the upper drive is 1. See the label on the back of the cage to change the jumpers if necessary. 3 stop Halts the specified processor. (Same as halt.) test Runs firmware diagnostics for the system. Remote Management Console (RMC) Commands alert_clr Clears alert flag, stopping dial-out alert cycle. alert_dis Disables the dial-out alert function. alert_ena Enables the dial-out alert function. disable Disables remote access to the modem port. enable Enables remote access to the modem port. Acoustics Declared values per ISO 9296 and ISO 7779, listed for the server/workstation. DS10 with 1 HDD LWAd, B LpAm, dBA (operator position) LpAm, dBA (bystander positions) 5.7 6.0 48 52 41 45 Idle Operating Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA. halt Halts the server. haltin Causes a halt assertion. Schallemissionswerte — Vorläufige Werteangaben nach ISO 9296 und ISO 7779/DIN EN27779: haltout Terminates a halt assertion created with haltin. DS10 mit 1 HDD hangup Terminates the modem connection. help or ? Displays the list of commands. poweroff Turns off power. poweron Turns on power. Aktuelle Werte für speziele Ausrüstungsstufen sind uber die Compaq quit Exits console mode and returns to system console port. Computer Vertretungen erhältelich. 1 B = 10 dBA. reset Resets the server. Emulates pressing the Reset button. setesc Changes the escape sequence for invoking command mode. setpass Changes the modem access password. status Displays system status and sensors. Leerlauf Betrieb Schalleistungspegel Schalldruckpegel LWAd, B LpAm, dBA (Bedienerposition) LpAm, dBA (Zuschauerpositionen) 5.7 6.0 48 52 41 45 For More Information • AlphaServer DS10 / DS10L and AlphaStation DS10 Console Reference (EK-DS10S-CR) • AlphaServer DS10 Quick Setup (EK-DS10S-CP) • Using a Web browser, follow links to the appropriate documentation from the URL: http://www.compaq.com/showroom/ 4
Home
Privacy and Data
Site structure and layout ©2025 Majenko Technologies