This document is an Installation Guide for the Digital Equipment Corporation (DEC) KMV1A-S series Programmable Communications Controller, designed for use in BA200-series microsystem enclosures.
Intended for DEC field service personnel and qualified self-maintenance customers, the guide provides comprehensive, step-by-step procedures covering:
- Pre-Installation: Emphasizing software backup, system shutdown, anti-static precautions, and verifying the existing system's functionality.
- Installation Procedures: Details unpacking and inspecting the option kit, checking system configuration (power and bus loads), guidelines for proper module placement to ensure bus continuity, and instructions for relocating existing modules.
- Configuration Settings: Explains how to determine and set critical CSR (Control/Status Register) addresses and interrupt vectors using either the SYSGEN CONFIG utility (for MicroVAX systems) or provided tables, along with setting interface and self-test switches.
- Post-Installation: Steps for verifying ground connections and connecting external devices using specific cables (BCC 04 for KMV1A-SF, BC 18Y for KMV1A-SG/SH).
- Testing the Configuration: Provides diagnostic procedures for both MicroVAX and MicroPDP-11 systems to test the newly installed KMV1A-S, including advice for troubleshooting.
The KMV1A-S is a microprocessor-based quad-height board for Q-bus based systems, supporting bit-oriented, byte-oriented synchronous, and asynchronous protocols. It comes in different options (KMV1A-SF, -SG, -SH) corresponding to RS232-C, RS422-A, and RS423-A electrical interfaces, respectively.