AlphaServer 1000 to AlphaServer 1000A Model 5/xxx Upgrade Information

Order Number: EK-AS42X-UP

This document provides step-by-step instructions for self-maintenance customers and service representatives to upgrade an AlphaServer 1000 system to an AlphaServer 1000A Model 5/xxx.

The upgrade process involves:

  1. Preparation: Safely shutting down and powering off the original system.
  2. Hardware Transfer: Systematically removing various components (top cover, side panels, StorageWorks hard drives, option cards, CD-ROM drive, and memory modules) from the AlphaServer 1000 and reinstalling them into the new AlphaServer 1000A Model 5/xxx enclosure provided in the upgrade kit. A critical caution notes that ECC SIMMs from the old system are not compatible with the new 5/xxx models and must be returned.
  3. Configuration Update: Rebuilding the EISA Configuration Data using the EISA Configuration Utility (ECU) diskette (V1.9 or later), ensuring the correct version for the specific operating system.
  4. RAID Firmware Update (if applicable): Strongly recommending updating the StorageWorks RAID controller firmware to version V3.11 or later, which includes creating a utility floppy and backing up existing configurations before proceeding.
  5. System Finalization: Verifying custom system settings/variables (CMOS for Windows NT, SRM console for Digital UNIX/OpenVMS), rebuilding the operating system kernel (for Digital UNIX systems), and booting the new system.
  6. Completion: Confirming the CPU speed on the operator control panel and arranging for the return of the old AlphaServer 1000 system.
EK-AS42X-UP-A01
September 1996
28 pages