This Field Change Order (FCO) addresses a "BUS hang" problem that occurs on OSF/1 systems utilizing ASE DECsafe software when two or more DWZZA-AA or DWZZA-VA units, shipped before September 1994, are connected to a differential SCSI bus.
To resolve this issue, the FCO mandates an upgrade: DWZZA-AA units must be at revision E01 or greater, and DWZZA-VA units at revision F01 or greater. Users are instructed to check the option tag for their current revision status. An alternative FCO, FCO-DWZZA-AA-S001, if already installed for specific DWZZA-AA serial numbers (CX409xxxxx to CX420XXXX), makes this FCO unnecessary.
The document provides detailed steps for removing the existing DWZZA-AA and DWZZA-VA options, including disconnecting power and SCSI cables, and subsequently installing the required upgraded revisions. The affected parts are the DWZZA-AA SCSI Adapter Table Top (EQ-01705-01) and the DWZZA-VA SCSI Adapter SBB (EQ-01710-01). Material costs for these parts are free of charge for customers under Warranty Optimum, Warranty Standard, and Warranty Basic (on-site) agreements.