FCO DECSK-AE-I001, DECSA-XX fused pwr cord fails (UK only)

Order Number: 17-00209-05

This Field Change Order (FCO DECSK-AE-I001) addresses an issue with DECSA-XX variants in the United Kingdom where the 5-ampere fused power cord sometimes fails upon power-up. The recommended solution is to replace the existing 5-ampere power cord with a new 13-ampere, 250-volt power cord (Part Number 17-00209-05).

The replacement procedure involves:

  1. Powering down the DECSA unit by setting the console key switch and circuit breaker to "OFF."
  2. Removing the old power cord and installing the new one.
  3. Powering up the DECSA unit by setting the circuit breaker and console key switch to "ON."
  4. Verifying that the power LED on the console is illuminated.

The estimated installation time for this change is 0.2 hours. This FCO was released on June 9, 1986, and is applicable to approximately 500 affected units.

17-00209-05
December 1986
Number of pages unknown
Quality

Original
3.7kB