FCO BA23-I002, DC power cable

Order Number: 70-20450-02

This document is a Field Change Order (FCO BA23-I002) for BA23C and BA23D Boxes, released on July 21, 1987. It addresses a critical issue where the original DC Power Cable (70-20450-02) was burning during normal use due to its derated current rating. The FCO mandates replacing this faulty cable with a new DC Power Cable (part number 17-01312-01), supplied as a wire harness assembly.

The FCO affects an estimated 550 units and is estimated to take one hour to install. Installation instructions include:

  1. Powering down the system and removing AC power from the cabinet.
  2. Gaining access to the DC Power Cable by sliding the box forward.
  3. Setting up an electrostatic discharge (ESD) prevention VELOSTAT kit to protect sensitive components.
  4. Removing the front cover and fan cowling (if present).
  5. Disconnecting the old DC Power Cable and installing the new one.
  6. Reinstalling components and powering up the system, ensuring self-tests run successfully.

The document also emphasizes critical safety cautions regarding AC power, cabinet stability, and ESD protection during the procedure. Post-installation, the Site Management Guide must be updated, and LARS data reported.

70-20450-02
December 1987
Number of pages unknown
Quality

Original
6.7kB