FCO 63XMX-F003 Rev C, Secondary proc fails RDB test, parity errors

Order Number: 23-188E9-00

This Field Change Order (FCO 63XMX-F003, Revision C), dated March 18, 1991, addresses issues with T2011-YA and T2011-YC CPU modules in VAX systems. The problems include intermittent secondary processor failures during RBD test 7 or ELKMP, duplicate Tag Parity Errors under heavy XMI activity, and Cache Tag Parity errors leading to specific system bugchecks.

The solution involves upgrading the failing modules by replacing them with newer revisions: AE01 for T2011-YA and AD01 for T2011-YC. The installation procedure includes an orderly system shutdown, using a Cache Exerciser Program (EQ-01596-03) to identify problematic modules, carefully replacing the electrostatic discharge sensitive (ESDS) components, restoring system serial numbers and boot specifications, and running various diagnostics (such as VAX Diagnostic Supervisor and EVUCA for multi-processor ROM patching) before bringing the system back online.

23-188E9-00
December 1991
Number of pages unknown
Quality

Original
16.5kB